Question_Set_5.pdf

PDF 278 KB Posted

Attached to
Storage Aid System at Holloman AFB, NM Federal contract opportunity
Solicitation number
FA8604-18-R-8104
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

About this file

Question Set #5

View the file

Other files for this federal contract opportunity

Other files attached to Storage Aid System at Holloman AFB, NM, newest first.
File Type Posted
FA8604-18-R-8104_0004.pdf PDF
Question_Set_4_.pdf PDF
FA8604-18-R-8104_0003.pdf PDF
FA8604-18-R-8104_0002.pdf PDF
Question_Set_3.pdf PDF
Question_Set_2.pdf PDF
Question_Set_1.pdf PDF
FA8604-18-R-8104_0001.pdf PDF
RFP_FA8604-18-R-8104.pdf PDF
RFP_FA8604-18-R-8104.pdf PDF
AHL706-04.dwg DWG drawing
AHL706-01.dwg DWG drawing
Proposal_Checklist-Pricing_Summary_Sheet.docx DOCX document
AHL706-03.dwg DWG drawing
AHL706-02.dwg DWG drawing
AHL706-05.dwg DWG drawing
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

16 March 2018

Holloman Question Set 5

Question 1: For the tire racks in Appendix J, is a row spacer required? The drawing doesn’t show one and the specs don’t mention one. Depending on the size of the tires being stored a space should be required for the overhang of the tires. Can you please clarify?

Answer: Row spacers are not required; however, a small gap will be left between back to back rows as shown with the tire rack to be removed picture in the Cover PD.

Question 2: Can you provide a drawing that locates the closest or most adequate electrical panel where the electrical needs for the modular building and MHS system can be tied in?

Answer: AF Drawings AHL706-04 and -05 have been updated to reflect electrical locations.

Question 3: The spec for “MC3” in Appendix D (Table 2) does not match the drawing and the spec’d drawers will not fit in the housing. Please advise whether there should be five (5) 3-7/8” and five (5) 5- 3/8” drawers or if it should match the drawing and other cabinets with 6 and 4 of the respective drawers.

Answer: Drawer configuration should match that of the other cabinets (6) 3—7/8” drawers and (4)5- 3/8” drawers. Appendix D has been updated to reflect this.

Question 4: 3.2.3.1 Drawing AHL706-05 does not show the source of power point even though the spec says it does. Can you please mark it on the drawing?

Answer: Previous questions have addressed this, drawings now show electric panels.

Question 5: Should the lower horizontal conveyor be an accumulating conveyor in the reverse direction?

Answer: Only the upper section shall be live roller accumulation conveyor as specified in App I.

Question 6: Is 3’5” between the edge of conveyor and the modular cabinets? The conveyor curve as drawn is not realistic and to make it that way requires the additional space moving it closer to the modular cabinets.

Answer: The drawing of the conveyor is conceptual in nature, exact curve dimensions may vary slightly to accommodate the turn. Walkway must be maintained on upper level of mezzanine so any shift must be done to the lower section.