PD13WRGRVEA05RevC30July2013.pdf

PDF 23 KB Posted

Attached to
500 Gallon Liquid Oxygen/Liquid Nitrogen Storage Tanks Federal contract opportunity
Solicitation number
FA8533-13-R-30278
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Robins Air Force Base

About this file

PD Rev C dtd 30 July 2013

View the file

Other files for this federal contract opportunity

Other files attached to 500 Gallon Liquid Oxygen/Liquid Nitrogen Storage Tanks, newest first.
File Type Posted
Post_Award_Announcement_Synopsis.doc DOC document
Q A_dtd_08062013.pdf PDF
FA853313R30278______0002.pdf PDF
Attachment1FACTSSheet_revised.pdf PDF
PD13WRGRVEA05 _Rev_B _dtd_25_July_2013.pdf PDF
Q A_dtd_07252013.pdf PDF
FA853313R30278______0001.pdf PDF
C004-SystemSafetyHazardAnalysisReport.pdf PDF
EDL2544.pdf PDF
B005-NoticeofRevision.pdf PDF
EDL1576.pdf PDF
AFMCForm158.pdf PDF
B004-EngineeringChangeProposal.pdf PDF
E003-InformationLMIDataProducts.pdf PDF
D001-TechnicalManualContractRequirements-Oxyge.pdf PDF
A006-InstructionalMediaPackage.pdf PDF
Attachment2Questionnaire.pdf PDF
FA853313R30278.pdf PDF
PurchaseDescription.pdf PDF
C002-CorrosionPreventionandControlPlan.pdf PDF
A005-DesignDataandCalculations.pdf PDF
A004-TechnicalReportStudyServices.pdf PDF
Attachment5TeamingPartnerConsentForm.pdf PDF
D002-TechnicalManualContractRequirements-Nitro.pdf PDF
B001-ContractorsProgressStatusManagementReport.pdf PDF
A003-ProductionReports.pdf PDF
B006-RequestforDeviation.pdf PDF
Attachment6QuantityRanges.pdf PDF
E001-InformationLMIDataProducts-Oxygen.pdf PDF
B003-ConferenceMinutes.pdf PDF
C001-WeldingProcedures.pdf PDF
Attachment1FACTSSheet.pdf PDF
A001-TestProcedure.pdf PDF
C005-ProductBaseLineIndex.pdf PDF
StatementWork.pdf PDF
E002-SupplementalDataforProvisioning-Oxygen.pdf PDF
A002-TestInspectionReports.pdf PDF
C003-SystemSafetyProgramPlan.pdf PDF
Attachment3TransmittalLetter.pdf PDF
E004SupplementalDataForProvisioning-Nitrogen.pdf PDF
CertificateofEquivalency.pdf PDF
B002-ConferenceAgenda.pdf PDF
Attachment4ClientAuthorizationLetter.pdf PDF
Show all 43

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PD13WRGRVEA05

CAGE 98752

Rev C 30 July 2013 Superseding Rev B 25 July 2013

PURCHASE DESCRIPTION

TANK, STORAGE, LIQUID OXYGEN/LIQUID NITROGEN

4.2 First article inspection.

Was: First article inspection and tests shall be performed on two complete tank assemblies (one of each type). Each first article tank assembly shall be subjected to the analyses, demonstrations, examinations, and tests described in 4.6.1 through 4.6.14.4. The contractor shall provide or arrange for all test equipment and facilities. Nonconformance to any specified requirement, the failure of any test, or the presence of one or more defects shall be cause for disapproval of first article.

Change to: First article inspection and tests shall be performed on two complete tank assemblies (one of each type). Each first article tank assembly shall be subjected to the analyses, demonstrations, examinations, and tests described in 4.6.1 through 4.6.14.4. Due to the similarities between the Type I and Type II tank assemblies, the Liquid Oxygen 500-gallon complete tank assembly shall be used for the environmental testing sections 4.6.7.2 through

4.6.7.11. The contractor shall provide or arrange for all test equipment and facilities.

Nonconformance to any specified requirement, the failure of any test, or the presence of one or more defects shall be cause for disapproval of first article.

4.6.7.1 Vibration.

Was: The tank assembly shall be filled to design capacity with a cryogenic liquid having a density of not less than 9.5 pounds per U.S. gallon and pressurized to not less than 45 psig. The filled and pressurized tank, with the servicing hose secured in the storage position, shall be subjected to the vibration testing specified in MIL-STD-810 method 514.6, category 4, 7 and 8, transportation, to show compliance with the requirements of 3.4.4. The tank assembly shall be carefully examined after each test phase and following completion of the overall test. Damage to or failure of any tank assembly components, loosening of fasteners, loss of instrument calibration, or loss of vacuum in the annular space shall be considered a failure of the tank assembly to pass the test.

Change to: The tank assembly shall be filled to design capacity with a cryogenic liquid having a density of not less than 9.5 pounds per U.S. gallon and pressurized to not less than 45 psig. The filled and pressurized tank, with the servicing hose secured in the storage position, shall be subjected to the vibration testing specified in MIL-STD-810 method 514.6, category 4, 7, 8, 10 and 11, transportation, to show compliance with the requirements of 3.4.4. The tank assembly shall be carefully examined after each test phase and following completion of the overall test.

Damage to or failure of any tank assembly components, loosening of fasteners, loss of instrument calibration, or loss of vacuum in the annular space shall be considered a failure of the tank assembly to pass the test.

File details come from the government source that posted it. Updated .