QALIF-15IFF.pdf

PDF 845 KB Posted

Attached to
Initiator Federal contract opportunity
Solicitation number
FA821320R3031
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

About this file

This document contains a quality assurance letter of instruction and related federal contract opportunity notice. The quality assurance letter outlines inspection requirements for an unnamed contractor producing critical flight items under contract number 20-50010, including mandatory stamps or signatures on documentation, witness requirements for testing, and notification timelines. The related federal contract opportunity is solicitation number FA821320R3031 issued by the Department of the Air Force Materiel Command Lifecycle Management Center. It includes line items for ejection system ballistic devices with part numbers like 1002-41 and 6284200, to be delivered by December 31, 2021. The opportunity also lists informational line items for the same products to foreign military sales countries.

View the file

Other files for this federal contract opportunity

Other files attached to Initiator, newest first.
File Type Posted
CDRL_20-50055.pdf PDF
JFQRGyro.pdf PDF
F012340719.pdf PDF
20-50036_20-50037_AIRSPEC.pdf PDF
JQR_7439.pdf PDF
REPSHIP11Mar14.pdf PDF
QALI_MG47_MG48.pdf PDF
HazClsforFD2020-20-50002_50003.pdf PDF
JQR016488442signed.pdf PDF
CDRLs_DD1423_Package_20-50083.pdf PDF
20-50071EDLs.pdf PDF
JQR01-414-8935.pdf PDF
F011676621.pdf PDF
F014551511.pdf PDF
5552ES_EDL.pdf PDF
F00-138-3770.pdf PDF
ID_002952166.pdf PDF
JQR01-448-3137.pdf PDF
JQR01-414-8934.pdf PDF
Itemdescriptions.pdf PDF
SOWSPI.pdf PDF
AIRSPEC_20-50071.pdf PDF
JQR011664265.pdf PDF
JQR014250548.pdf PDF
F010528206.pdf PDF
F010528208.pdf PDF
DD1423CDRL20-50071.pdf PDF
F013193847.pdf PDF
IHC_CED_DGC.pdf PDF
8206ES__EDL.pdf PDF
ADCSOWJan2018.pdf PDF
20-50083EDLs.pdf PDF
QALI_20-50083.pdf PDF
JQR01-318-7696.pdf PDF
3847ES_EDL.pdf PDF
EDL_Combined.pdf PDF
F012717161.pdf PDF
20-50036_20-50037CDRLS.pdf PDF
AIRSPEC_20-50055.pdf PDF
JQR01-318-7697.pdf PDF
QALI20-50002_50003F-15_initiators.pdf PDF
20-50071ItemDescriptions.pdf PDF
ItemDescription_50002_50003.pdf PDF
JQR014148933.pdf PDF
20-50083ItemDescriptions.pdf PDF
JQR00-295-2166.pdf PDF
JFQRHRC.pdf PDF
AIRSPEC2050002_50003_updated.pdf PDF
JQR002991512.pdf PDF
FA821320R3031_______0001 Synopsis.pdf PDF
Show all 50

Initiator has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contractor Name CAGE code

DCMA QAR Reviewer

Date Review Completed

Date Issued to Contractor

PR No. FD2020-

Date Contract Awarded

Final Delivery Date (FDD)

Program Name

DODIC

Part Number

The contractor is required to impose the listed below DCMA Inspection Points into the appropriate Work Orders.

All Work Orders pertaining to CRITICAL FLIGHT ITEMS must be identified on folders.

Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)

Witness - W: GSI required to attend, may reduce level of effort after 50% of production lots found acceptable Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification) Monitor - R: Will monitor testing, may reduce to verification Notify - N: By phone or daily schedule 24( R ) - 48 ( NR ) hours in advance

Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)

Prepared by:

Date

Concurrence Signature by QAR/DCMA:

QAR/DCMA Signature

THIS PLANNING SHEET WILL BE UPDATED IF NECESSARY.

QUALITY ASSURANCE LETTER OF INSTRUCTION

Planning Requirements

COMMENTS

NOTICE

Engineer Signature

Date

Rev Date: 30 April 2019

Sheet1

Text49:
Text46:
undefined_9: N
Text32: 9. Additional Requirements
undefined_8: M
Text31: 8. Shippers (DD250, DD1149, Reports)
undefined_7: M
Text30: 7. AMMO Data Card Review
undefined_6: V
Text29: 6. Preparation for Shipment
undefined_5: W
Text28: 5. LAT
undefined_4: V
Text27: 4. LAT Sample Selection
undefined_3: V
Text26: 3. X-Ray/N-Ray
undefined_2: M
Text25: 2. Leak Test
undefined: V
Text36: 1. Explosive Weight

2. Verify gross leak and fine leak check are performed.

3. Ensure film labeling correct. Ensure radiographic film is readable and well-defined. DCMA is not required to interpret film.

4. Randomly select LAT units per latest government approved ATP. Prior to LAT ensure proper calibration and validation of all test equipment.

5. Testing should occur in accordance with latest government approved ATP. Witness proper test setup and at least the first 3 functional tests. Further witness may be required if there are known concerns with the item or requested by Government Engineer.

6. Ensure Paperwork is correct.

7. Verify all energetic materials: list original manufacturer,original lot number, and latest certification/recertification date < 24 months.

8. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)

9. Any additional requirements imposed by DCMA shall be approved by Government Project Engineer

Text24: 1.Inspection
Part Number: 1040-3, 6128100
Text23:
DODIC: SP98
Text22:
Text21:
Text20:
Text19:
Part Number Line 2:
Contract No: 20-50010
Date Contract Awarded:
Final Delivery Date FDD:
Program Name: F-15