08_33_13_Rolling_Counter_Doors_-_Hill_AFB.pdf
PDF 22 KB Posted
- Attached to
- Renovation and Repair Building 238
- Solicitation number
- FA8201-15-R-RENO
About this file
Amendment 3 Additional DOC 08 33 13
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FA8201-15-B-0001-0005.pdf | ||
| Drawing_Clarification_Document_1_June_2015.docx | DOCX document | |
| Bid_Opening_Information.docx | DOCX document | |
| Q_and_A__2.docx | DOCX document | |
| Amendment_4.pdf | ||
| Amendment_3.pdf | ||
| KRSM238_142063_IFC_20150323_Combined_34x22(5-18-15).pdf | ||
| QA_Responses_RENO.docx | DOCX document | |
| 238_Pictures__4.zip | ZIP file | |
| 238_Pictures__3.zip | ZIP file | |
| 238_Pictures__2.zip | ZIP file | |
| 238_Pictures__1.zip | ZIP file | |
| Building_238_Amendment_2.pdf | ||
| 238_Site_Visit_List.docx | DOCX document | |
| Building_238_Amendment_1.pdf | ||
| FA8201-15-B-0001_Solicitation.zip | ZIP file |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 08 33 13 Page 1
SECTION TABLE OF CONTENTS
DIVISION 08 - OPENINGS
SECTION 08 33 13
METAL ROLLING COUNTER DOORS
05/09
PART 1 GENERAL
1.1 REFERENCES 1.2
SUSTAINABILITY REPORTING
1.3 SUBMITTALS
1.4 QUALITY ASSURANCE
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 WARRANTY
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
2.2 BASIC COMPONENTS
2.2.1 Curtain
2.2.2 Jamb Guides
2.2.3 Counterbalance Shaft Assembly
2.2.4 Brackets
2.2.5 Hood
2.2.6 Locks
2.3 ROLLING COUNTER DOOR (NON-RATED)
2.4 FIRE-RATED ROLLING COUNTER DOOR
2.5 INTEGRAL FRAME ROLLING COUNTER DOOR (RATED OR NON-RATED)
2.6 AUTOMATIC CLOSING DEVICE
2.7 FINISH
PART 3 EXECUTION
3.1 INSTALLATION
3.2 OPERATION
3.2.1 Manual Operation
3.2.2 Power Operation
3.3 TESTS
3.4 FIELD FINISHING
3.5 CLEANING
-- End of Section Table of Contents --
SECTION 08 33 13 Page 2
SECTION 08 33 13
METAL ROLLING COUNTER DOORS
05/09
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A240/A240M (2014) Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications
ASTM A653/A653M (2013) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc- Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM B209 (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate
ASTM B209M (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Metric)
ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM B221M (2013) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 80 (2013) Standard for Fire Doors and Other Opening Protectives
U.S. GREEN BUILDING COUNCIL (USGBC)
LEED BD+C (2009; R 2010) Leadership in Energy and Environmental Design(tm) Building Design and Construction (LEED-NC)
1.2 SYSTEM DESCRIPTION
Furnish rolling counter doors with stainless steel counter, of the type, size, and design indicated on the drawings. Provide the standard product of a manufacturer regularly engaged in the production of rolling counter doors. Provide each door with a permanent label showing the manufacturer's name and address and the model number of the door. Submit Manufacturer's descriptive data and catalog cuts.1.3 SUBMITTALS
SECTION 08 33 13 Page 3
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for [Contractor Quality Control approval.] [information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.] Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES of Solicitation KRSM 142063:
SD-02 Shop Drawings
Detail Drawings
SD-03 Product Data
Warranty Rolling Counter Doors Installation Cleaning
SD-06 Test Reports
Drop-test
SD-10 Operation and Maintenance Data
SD-11 Closeout Submittals
LEED Documentation
Rolling Counter Door (Non-Rated) Fire-Rated Rolling Counter Door
1.4 QUALITY ASSURANCE
Submit Detail Drawings showing elevations of each door type, details of anchorage, details of construction, location and description of hardware, shape and thickness of materials, details of joints and connections, and details of guides and fittings. Include a schedule showing the location of each counter door with the drawings.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver rolling counter doors to the jobsite wrapped in a protective covering with the brands and names clearly marked thereon. Store rolling counter doors in accordance with the manufacturer's instructions in a dry location that is adequately ventilated and free from dust, water, or other contaminants, and in a manner that permits easy access for inspecting and handling. Handle doors carefully to prevent damage. Replace damaged items that cannot be restored to like-new condition.
1.6 WARRANTY
SECTION 08 33 13 Page 4
Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period. Submit no later than 30 days prior to final inspection.
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
Furnish rolling counter doors of the type, size, and design indicated on the drawings. Provide the standard product of a manufacturer regularly engaged in the production of rolling counter doors. Provide each door with a permanent label showing the manufacturer's name and address and the model number of the door. Submit Manufacturer's descriptive data and catalog cuts.
2.2 BASIC COMPONENTS
2.2.1 Curtain
Fabricate the curtain of 22 gauge galvanized steel slats conforming to ASTM A653/A653M, Coating Designation G90. Provide thickness of slat material as required by width of opening. Use slats approximately 1-1/4 to 1-1/2 inch wide with a depth of crown of 1/2 inch. Fit alternate slats with endlocks to maintain curtain alignment. Provide bottom of curtain with angle or tubular bar reinforcement matching the curtain, and fitted with a resilient bottom seal.
2.2.2 Jamb Guides
Furnish guides of 13 gauge minimum thickness galvanized steel angles conforming to ASTM A653/A653M, Coating Designation minimum G40.
2.2.3 Counterbalance Shaft Assembly
Furnish the curtain coiled around a steel tube of sufficient thickness and diameter to prevent deflection exceeding 0.03 inch per foot. Provide a barrel containing oil tempered helical steel torsion springs capable of sufficient torque to counterbalance the weight of the curtain. Calculate the springs to provide a minimum of 7,500operating cycles (one complete cycle of door operation will begin with the door in the closed position, move to the full open position and return to the closed position).
2.2.4 Brackets
Furnish brackets of a minimum 12 gauge thickness steel if flat plate, or 16 gauge thickness if there are a minimum of 3 returns of 3/4 inch width.
2.2.5 Hood
Provide a hood of 24 gauge galvanized steel conforming to ASTM A653/A653M, Coating Designation minimum G40.
2.2.6 Locks
Lock the curtain at [each side of the bottom bar by an integral slide bolt] [both sides of bottom bar by a chrome-plated cylinder lock keyed into the
SECTION 08 33 13 Page 5 building keying system]. Locate lock on the [_____] room side of the counter door. [Provide keying [conforming to Section 08 71 00 DOOR HARDWARE] [as indicated].]
2.3 ROLLING COUNTER DOOR (NON-RATED)
Construct rolling counter doors, curtains, guides and hood components of galvanized steel conforming to the requirements specified herein. Submit complete copies of Data Package 2 for Rolling Counter Doors (Non-Rated) and Fire-Rated Rolling Counter Doors (next paragraph) in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA. Provide a list of the parts recommended by the manufacturer to be replaced after 1 yearof service.
2.4 FIRE-RATED ROLLING COUNTER DOOR
Furnish fire-rated rolling counter doors, as shown and conforming to the requirements specified and to NFPA 80 for the class indicated. Provide labels of a recognized testing agency for the doors, indicating the applicable fire resistance rating. The construction details necessary for labeled rolling counter doors will take precedence over details indicated or specified herein. Furnish door curtains, guides and hood of galvanized steel. Provide fire-rated rolling counter doors complete with hardware, accessories, and automatic closing device. Provide rolling counter doors, in exit corridor walls, with perimeter smoke and draft control gasketing.2.5
INTEGRAL FRAME ROLLING COUNTER DOOR (RATED OR NON-RATED)
Furnish integral frame rolling counter door of galvanized steel as shown .] Conform fire-rated doors to the requirements of NFPA 80 for the Class indicated and bearing the labels of a recognized testing agency indicating the applicable fire resistance rating. Form jambs to create guides for the curtain. Provide head and jambs of 16 gauge thickness. Provide counter of 14 gauge thickness. Provide rolling counter doors, in exit corridor walls, with perimeter smoke and draft control gasketing.
2.6 AUTOMATIC CLOSING DEVICE
Equip fire-rated counter doors with an automatic closing device which operates upon fire alarm systemor as indicated. Furnish fire and smoke doors that easily reset by the facility user after they have been released by the detection system. Resetting the door shall not require the use of special tools.
2.7 FINISH
Exposed parts of the counter door, including the curtain, bottom rail, guides, and hood shall be of uniform finish and appearance. Furnish steel galvanized coating with a prime coat and a baked-on or powder-coated Factory top coat finish. Give all other steel parts a shop coat of primer paint standard with the manufacturer. Provide a factory coated color as indicated.
SECTION 08 33 13 Page 6
PART 3 EXECUTION
3.1 INSTALLATION
Install doors in accordance with approved detail drawings and manufacturer's instructions. Accurately locate anchors and inserts for guides, brackets, hardware, and other accessories. Upon completion, doors shall be free from warp, twist, or distortion. Lubricate, properly adjust, and demonstrate doors to operate freely. Conform fire-door installation with NFPA 80 for the class indicated and the manufacturer's instructions.
3.2 OPERATION
3.2.1 Manual Operation
Provide curtain operated by means of manual push-up with lift handles or continuous full width lift bar, as indicated.
3.3 TESTS
Drop-test the fire doors in accordance with NFPA 80 to show proper operation and full automatic closure and reset in accordance with the manufacturer's instructions. Provide a written record of initial test to the Contracting Officer.
3.5 CLEANING
Clean counter and doors in accordance with manufacturer's approved instructions. Submit Manufacturer's preprinted installation and cleaning instructions.
-- End of Section --
| 05/09 |
| 05/09 |
File details come from the government source that posted it. Updated .