Attachment_Change_Matrix_-_1-19-2017.xlsx

XLSX spreadsheet 12 KB Posted

Attached to
USAF Fire Emergency Services Personal Protective Services (FES PPE) Ensemble Federal contract opportunity
Solicitation number
FA8056-17-R-0001
Issued by
Department of the Air Force Materiel Command Installation and Mission Support Center Installation Contracting Agency

About this file

Attachment Change Matrix - for informational purposes only (Amendment 0002)

View the file

Other files for this federal contract opportunity

Other files attached to USAF Fire Emergency Services Personal Protective Services (FES PPE) Ensemble, newest first.
File Type Posted
Attachment_Change_Matrix_-_2-XX-2017.xlsx XLSX spreadsheet
FA8056-17-R-0001_0004_SF_30.pdf PDF
Attachment_5_-_FES_PPE_Technical_Evaluation_Matrix.xlsx XLSX spreadsheet
Attachment_3_-_FES_PPE_Ensemble_Product_Category_Specifications.xlsx XLSX spreadsheet
FA8056-17-R-0001_Final_RFP_Q&A_posted_02_02_17.pdf PDF
Attachment_2_-_FES_PPE_Ensemble_Pricing_Matrix.xlsx XLSX spreadsheet
Attachment_Change_Matrix_-_1-27-2017.xlsx XLSX spreadsheet
DoD_EMALL_-_Registration_Process_Improvement_Guide.pdf PDF
DOD_EMALL_-_Supplier_Informational_Package.pdf PDF
Attachment_5_-_FES_PPE_Technical_Evaluation_Matrix.xlsx XLSX spreadsheet
DoD_EMALL_-_Contractor_Registration.pdf PDF
DoD_EMALL_-_Supplier_Registration_-_CAC-PKI.pdf PDF
FA8056-17-R-0001_0003.docx DOCX document
FA8056-17-R-0001_0003_SF30.pdf PDF
FA8056-17-R-0001_Final_RFP_posted_01_27_17.docx DOCX document
FA8056-17-R-0001_Final_RFP_posted_01_26_17.docx DOCX document
FA8056-17-R-0001_0002_SF_30.pdf PDF
FA8056-17-R-0001_0002_SF_30.docx DOCX document
FA8056-17-R-0001_0002.docx DOCX document
Attachment_4_-_FES_PPE_Ensemble_Statement_of_Work.pdf PDF
Attachment_3_-_FES_PPE_Ensemble_Product_Category_Specifications.xlsx XLSX spreadsheet
Attachment_6_-_FES_PPE_Past_Performance_Questionnaire.pdf PDF
Attachment_5_-_FES_PPE_Technical_Evaluation_Matrix.xlsx XLSX spreadsheet
Attachment_2_-_FES_PPE_Ensemble_Pricing_Matrix.xlsx XLSX spreadsheet
FA8056-17-R-0001_Final_RFP_posted_01.17.17.docx DOCX document
usps-military-mail-guide[1].pdf PDF
FA8056-17-R-0001_Draft_RFP_posted.pdf PDF
Attachment_4_-_FES_PPE_Ensemble_Statement_of_Work.pdf PDF
Attachment_5_-_FES_PPE_Technical_Evaluation_Matrix.xlsx XLSX spreadsheet
Attachment_1_-_FES_PPE_Ensemble_Proposal_Cover_Sheet.xlsx XLSX spreadsheet
Attachment_2_-_FES_PPE_Ensemble_Pricing_Matrix.xlsx XLSX spreadsheet
Attachment_6_-_FES_PPE_Past_Performance_Questionnaire_boxed.pdf PDF
Attachment_9_-_CDRL_A002.pdf PDF
Attachment_3_-_FES_PPE_Ensemble_Product_Category_Specifications.xlsx XLSX spreadsheet
FA8056-17-R-0001.docx DOCX document
Attachment_7_-_FES_PPE_List_of_USAF_Fire_Stations.xlsx XLSX spreadsheet
FA8056-17-R-0001_0001.pdf PDF
Attachment_8_-_CDRL_A001.pdf PDF
FA8056-17-R-0001_Draft_RFP.pdf PDF
CDRL_A001.pdf PDF
Attachment_1_-_FES_PPE_Ensemble_Proposal_Cover_Sheet.xlsx XLSX spreadsheet
Attachment_2_-_FES_PPE_Ensemble_Pricing_Matrix.xlsx XLSX spreadsheet
Attachment_3_-_FES_PPE_Ensemble_Product_Category_Specifications.xlsx XLSX spreadsheet
Attachment_7_-_FES_PPE_List_of_USAF_Fire_Stations.xlsx XLSX spreadsheet
CDRL_A002.pdf PDF
Attachment_4_-_FES_PPE_Ensemble_Statement_of_Work.pdf PDF
Attachment_6_-_FES_PPE_Past_Performance_Questionnaire.pdf PDF
Attachment_5_-_FES_PPE_Technical_Evaluation_Matrix.pdf PDF
Show all 48

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

AttachmentTABRequirementOriginal LanguageUpdated LanguageSummary of Change
RFP Attachment 2 - FES PPE Ensemble Pricing MatrixTAB - A Structural GarmentsCLIN x0003 Structural SuspendersOriginal Quantities:

CLIN x003 Structural Suspenders AA – X Short 300 AB – Short 500 AC – Regular 800 AD – Long 400

TOTAL 2000

New Quantities:

CLIN x003 Structural Suspenders AA – X Short 630 AB – Short 1050 AC – Regular 1680 AD – Long 840

TOTAL 4200

Aligned number of suspenders with total number of ensembles.
RFP Attachment 2 - FES PPE Ensemble Pricing MatrixTAB - B Proximity GarmentsCLIN x0007 Proximity GarmentsOriginal Quantities:

CLIN x003 Structural Suspenders AA – X Short 300 AB – Short 500 AC – Regular 800 AD – Long 400 TOTAL 2000 New Quantities:

CLIN x007 Proximity Suspenders AA – X Short 348 AB – Short 580 AC – Regular 930 AD – Long 464

TOTAL 2322

Aligned number of suspenders with total number of ensembles.
RFP Attachment 2 - FES PPE Ensemble Pricing MatrixTAB - B Proximity GarmentsCLIN x005 Proximity Coat, AG - Add Flashlight StrapOriginal quantity - 2,100 (annually)Updated quantity - 100 (annually)Typo. Updated annual quantities.
RFP Attachment 2 - FES PPE Ensemble Pricing MatrixTAB - A Structural GarmentsCLIN x004 Structural Garment Sizing KitsN/A (was not a requirement)Structural Garment Sizing Kits (Women’s): 5 kits for base, options 1-4. 3 kits for the 6 month optionNeeded to add gender-specific sizing kits.
RFP Attachment 2 - FES PPE Ensemble Pricing MatrixTAB - B Proximity GarmentsCLIN x008 Structural Garment Sizing KitsN/A (was not a requirement)Proximity Garment Sizing Kits (Women’s) 5 kits for base, options 1-4. 3 kits for the 6 month option.Needed to add gender-specific sizing kits.
RFP Attachment 3 - FES PPE Ensemble Product Category SpecificationsTAB - B Proximity Garments1.3.4 - Personnel SizingThe contractor shall provide a controlled sample sizing kit with measurement guide and instructions identified in 1.3. above to properly size proximity coat and pant garments.The contractor shall provide a controlled sample sizing kit with measurement guide and instructions on how to properly size the following: coat chest, coat sleeve, pant waist, pant inseam, and pant hips (women).Mirrored what was stated in TAB A. More detailed.
RFP Attachment 3 - FES PPE Ensemble Product Category SpecificationsTAB - B Proximity Garments1.3.4.1 - Sizing KitN/A (was not a requirement)The contractor shall provide a controlled sample sizing kit with measurement guide and instructions on how to properly size men and women to capture proper fit and accurate interfacing of sleeve/glove, coat/pant, and pant/boot. Kit contents shall include a maximum of seven skipped size sets of coats and pants with common identified sleeve/pant lengths within the sizing ranges identified in 1.3.1. and 1.3.2. above and utilized to capture sizing for proximity coat and pants. Sizing garments shall be easily identifiable or clearly marked as sizing garments to prevent utilization as compliant PPE garments.Added. Was not in the Proximity requirements.
RFP Attachment 3 - FES PPE Ensemble Product Category SpecificationsTAB - B Proximity Garments1.3.4.2 - Bench Stock SizingN/A (was not a requirement)The contractor shall provide a specific sizing chart from the manufacturer to include sizing ranges and assist with determination of sizing for PPE in support of sustainment bench stock or bulk requirements.Added. Was not in the Proximity requirements.
RFP Attachment 3 - FES PPE Ensemble Product Category SpecificationsTAB - A Structural Garments3.6 - Fly ZipperN/A (was not a requirement)3.6 Fly Zipper. The pant shall incorporate a #10 heavy duty high temperature smooth-gliding non-conductive zipper made with plastic (polyacetal resin). The teeth of the zipper shall be mounted on Nomex® or equal flame resistant meta-aramid tape.Needed zipper requirement.
RFP Attachment 3 - FES PPE Ensemble Product Category SpecificationsTAB - A Structural GarmentsAll Reqs after 3.6 Fly Zipper in Section 3 - Structural Fire Fighting PantsN/AN/ARenumbered all subsequent requirements to 3.6 - Fly Zipper
RFP Attachment 3 - FES PPE Ensemble Product Category SpecificationsTAB - B Proximity Garments3.5 - Fly ZipperN/A (was not a requirement)3.5. Fly Zipper. The pant shall incorporate a #10 heavy duty high temperature smooth-gliding non-conductive zipper made with plastic (polyacetal resin). The teeth of the zipper shall be mounted on Nomex® or equal flame resistant meta-aramid tape.Needed zipper requirement.
RFP Attachment 3 - FES PPE Ensemble Product Category SpecificationsTAB - B Proximity GarmentsAll Reqs after 3.5 Fly Zipper in Section 3 - Proximity Fire Fighting PantsN/AN/ARenumbered all subsequent requirements to 3.5. - Fly Zipper
RPF Attachment 4- FES PPE Ensemble Statement of WorkN/AN/AN/Aa. E-Ordering

The Air Force has partnered with the Defense Logistics Agency (DLA) in the use of their E-Ordering system the Department of Defense Electronic Mall (DOD EMALL). This award will require the posting of all items in a catalog on the DOD EMALL system.

Added 9(a) under General Information in the SOW to cover E-Ordering.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - A Structural Garments1.3.5.1 - Sizing KitThe contractor shall provide a controlled sample sizing kit with measurement guide and instructions on how to properly size men and women to capture proper fit and accurate interfacing of sleeve/glove, coat/pant, and pant/boot. Kit contents shall include a maximum of seven skipped size sets of coats and pants with common identified sleeve/pant lengths within the sizing ranges identified in 1.3.2. and 1.3.3.. above and utilized to capture sizing for structural and/or proximity (reference 10.2.4. for proximity) coat and pants. Sizing garments shall be easily identifiable or clearly marked as sizing garments to prevent utilization as compliant PPE garmentsThe contractor shall provide a controlled sample sizing kit with measurement guide and instructions on how to properly size men and women to capture proper fit and accurate interfacing of sleeve/glove, coat/pant, and pant/boot. Kit contents shall include a maximum of seven skipped size sets of coats and pants with common identified sleeve/pant lengths within the sizing ranges identified in 1.3.2. and 1.3.3.. above and utilized to capture sizing for structural coat and pants. Sizing garments shall be easily identifiable or clearly marked as sizing garments to prevent utilization as compliant PPE garments.Removed reference to Proximity from the Structural requirement.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - B Proximity Garments1.3.4 - Personnel SizingThe contractor shall provide a controlled sample sizing kit with measurement guide and instructions identified in 1.3. above to properly size proximity coat and pant garments.The contractor shall provide a controlled sample sizing kit with measurement guide and instructions on how to properly size the following: coat chest, coat sleeve, pant waist, pant inseam, and pant hips (women).Mirrored what was stated in TAB A. More detailed.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - B Proximity Garments1.3.4.1 - Sizing KitN/A (was not a requirement)The contractor shall provide a controlled sample sizing kit with measurement guide and instructions on how to properly size men and women to capture proper fit and accurate interfacing of sleeve/glove, coat/pant, and pant/boot. Kit contents shall include a maximum of seven skipped size sets of coats and pants with common identified sleeve/pant lengths within the sizing ranges identified in 1.3.1. and 1.3.2. above and utilized to capture sizing for proximity coat and pants. Sizing garments shall be easily identifiable or clearly marked as sizing garments to prevent utilization as compliant PPE garments.Added. Was not in the Proximity requirements.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - B Proximity Garments1.3.4.1 - Sizing KitN/A (was not a requirement)N/AAdded 1.3.4.1 "evaluation critiria" to Evaluation Matrix.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - B Proximity Garments1.3.4.2 - Bench Stock SizingN/A (was not a requirement)The contractor shall provide a specific sizing chart from the manufacturer to include sizing ranges and assist with determination of sizing for PPE in support of sustainment bench stock or bulk requirements.Added. Was not in the Proximity requirements.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - B Proximity Garments1.3.4.2 - Bench Stock SizingN/A (was not a requirement)N/AAdded 1.3.4.2 "evaluation critiria" to Evaluation Matrix.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - A Structural Garments3.6 - Fly ZipperN/A (was not a requirement)3.6 Fly Zipper. The pant shall incorporate a #10 heavy duty high temperature smooth-gliding non-conductive zipper made with plastic (polyacetal resin). The teeth of the zipper shall be mounted on Nomex® or equal flame resistant meta-aramid tape.Added independent zipper requirement.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - A Structural Garments3.6 - Fly ZipperN/AN/AAdded 3.6 "evaluation critiria" to Evaluation Matrix.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - A Structural GarmentsAll Reqs after 3.6 Fly Zipper in Section 3 - Structural Fire Fighting PantsN/AN/ARenumbered all subsequent requirements to 3.6 - Fly Zipper
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - B Proximity Garments3.5 - Fly ZipperN/A (was not a requirement)3.5. Fly Zipper. The pant shall incorporate a #10 heavy duty high temperature smooth-gliding non-conductive zipper made with plastic (polyacetal resin). The teeth of the zipper shall be mounted on Nomex® or equal flame resistant meta-aramid tape.Added independent zipper requirement.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - B Proximity Garments3.5 - Fly ZipperN/AN/AAdded 3.5 "evaluation critiria" to Evaluation Matrix.
RFP Attachment 5 - FES PPE Technical Evaluation MatrixTAB - B Proximity GarmentsAll Reqs after 3.5 Fly Zipper in Section 3 - Proximity Fire Fighting PantsN/AN/ARenumbered all subsequent requirements to 3.5. - Fly Zipper
RFP Attachment 6 - FES PPE Past Performance QuestionnaireN/AN/AN/AN/AUpdated Radio Buttons to allow a single selection at each question.

File details come from the government source that posted it. Updated .