This document contains a laboratory report and letter regarding analysis of hazardous materials at a building demolition project at Fort Eustis Army Base in Virginia. The Marine Chemist Service laboratory analyzed samples from the site and found the lead level from a TCLP test to be below EPA standards for hazardous waste. The laboratory holds various accreditations covering asbestos, lead, PCB, and hazardous waste analysis. The letter was sent to an architecture firm as part of their work on the Fort Eustis Multi Building Demolition Project, a solicitation issued by the Air Force Air Combat Command to demolish multiple buildings at Fort Eustis with bids due in September 2019.
2799 HAZMAT LETTER
View the file
Other files for this federal contract opportunity
Show all 50
Fort Eustis Multi Building Demolition Project has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Credentials Agency Scope
Approval DOD-US Navy Resin
Accreditation ABS Hull Thickness
Accreditation AIHA-LAP, LLC Laboratory ID: 100551
ELLAP Paint, Soil, Wipe & Air
EMLAP Direct Examination: Air & Tape
IHLAP Asbestos: PCM
Dust: Gravimetry
Metals: Air
Accreditation NIST Laboratory Code: 200628-0
NVLAP Asbestos Bulk: PLM
Virginia Certification VELAP Laboratory No: 460257
NELAC RCRA 8 Metals: TCLP & NPW
Virginia Laboratory DGS - DPOR License No.: 3333 000004
Asbestos: PLM & PCM
NOTE: Laboratory Credentials cover only to the scopes listed above.
M
C
S Marine Chemist Service, Inc.
11850 TUG BOAT LANE
NEWPORT NEWS, VA 23606-2527
TEL: (757) 873-0933 · NORFOLK (757) 640-1122
FAX: (757) 873-1074 · NORFOLK (757) 625-5696
www.MarineChemist.com
SAMPLING ANALYSIS, CONSULTING, WRITTEN PLANS / SPECIFICATIONS AND TRAINING CLASSES
SPECIALIZING IN ASBESTOS, LEAD, PCB, HAZARDOUS WASTE, MOLD
CERTIFIED MARINE CHEMIST AND INDUSTRIAL HYGIENIST INSPECTIONS
BURNING HOSE ID & SECURITY DEVICE, NON-DESTRUCTIVE TESTING
NON-SPARKING SAFETY TOOLS, VENTILATION SALES
October 30, 2017
Guernsey Tingle Architecture
4350 New Town Avenue, Suite 101
Williamsburg, Virginia 23188
Attention: Kevin Panchision
Reference: Building 2799 Fort Eustis Army Base
MCS Job #17-106S
Dear Mr. Panchision:
Please find enclosed the Other Hazardous Materials Table and the Marine Chemist Service, Inc. TCLP Laboratory Report of Analysis for the above referenced job site (MCS # 0120286). The Lead TCLP level is below EPA standards for hazardous waste.
If you have any questions, please do not hesitate to contact us.
Sincerely, Patrick Studley, CIH
Virginia Asbestos Inspector
License #3303 003193
Reported TCLP Level <0.10 mg/L
Mercury Thermostats
Present? No
How Many? N/A
PCB Light Ballasts
Present? Yes
How Many? 70
Number of
Fluorescent Tubes? 140
Number of Compact
Fluorescent Tubes? 14
Number of Circular
Fluorescent Tubes? 76
Units with Refrigerant
Present? Exterior and Window
How Many?
2 Exterior and 1
Window
Building 2799
Other Hazardous Materials