22399.14 | JFSD200143A-B/JFSD949951A-C A-1 Stanley Consultants
Appendix A
Non-Destructive Lead-Based Paint and Asbestos Survey
Prepared by Peer Engineering, Inc.
LIMITED LEAD-BASED PAINT &
ASBESTOS SURVEY
Grand Forks Air Force Base JFSD 200143B – Portions of Building 314
Grand Forks, North Dakota
Prepared For:
Stanley Consultants, Inc.
November 11, 2011
Limited LBP and Asbestos Survey – Peer #21835.00 Building 314 – Grand Forks Air Force Base, ND ii
Peer Engineering, Inc.
LIMITED LEAD-BASED PAINT & ASBESTOS SURVEY
GRAND FORKS AIR FORCE BASE
JFSD 200143B – PORTIONS OF BUILDING 314
GRAND FORKS, NORTH DAKOTA
(Peer File #21835.00)
Prepared For:
Stanley Consultants, Inc.
5775 Wayzata Boulevard, Suite 300
Minneapolis, Minnesota 55416
Prepared by:
819 30th Avenue South, Suite 202 Moorhead, Minnesota 56560
(218) 477-6060
November 11, 2011
Limited LBP and Asbestos Survey – Peer #21835.00 Building 314 – Grand Forks Air Force Base, ND ii
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 PURPOSE
1.2 DEFINITIONS
2.0 ASBESTOS
2.1 OVERVIEW
2.2 PREVIOUS ASBESTOS SURVEY
2.3 SUSPECT ACM TARGETED FOR SAMPLING
Non-Suspect Material Suspect Materials
2.4 ACM TESTING RESULTS
2.5 LIMITATIONS
3.0 LEAD-BASED PAINT
3.1 OVERVIEW
3.2 RESULTS
3.3 LIMITATIONS
4.0 HAZARDOUS MATERIALS
5.0 CONCLUSIONS AND RECOMMENDATIONS
6.0 SUMMARY OF QUALIFICATIONS
LIST OF FIGURES
Figure 1 - Site Location Map Figure 2 - Building Location Map
LIST OF APPENDICES
Appendix A - Asbestos Analytical Results Appendix B - Asbestos Sample Summary Table Appendix C - Asbestos Sample Location Diagrams Appendix D - Lead-Based Paint Testing Results Appendix E - Lead-Based Paint Sample Location Diagram Appendix F - Summary of Qualifications
Limited LBP and Asbestos Survey – Peer #21835.00 1 Building 314 – Grand Forks Air Force Base, ND
1.0 INTRODUCTION
1.1 PURPOSE
Peer Engineering, Inc. (Peer) was retained by Stanley Consultants, Inc. (the Client) to perform a limited Lead-Based Paint and Asbestos Survey (the Work) in portions of Building 314 at the Grand Forks Air Force Base, Grand Forks County, North Dakota.
Building 314 is comprised of both maintenance shop facilities, general office space, and five secured access areas. The Client provided Peer with a series of base maps indicating the proposed work areas within Building 314 (the Project area). Areas outside of the Project Area were not included in the Work, unless otherwise instructed.
The hallways were assigned arbitrary numbers for identification purposes during the performance of the Work and for this report; the offices are identified by their associated office numbers at the time of the Work. A diagram depicting the location of the Grand Forks Air Force Base (GFAFB) is included as Figure 1; a diagram depicting the location of Building 314 is included as Figure 2. The Project Area is scheduled to have significant interior and exterior renovations, including some roofing.
The Work was completed by Mr. Jason Gelling of Peer, on November 2, 2011. Mr.
Gelling is a North Dakota Department of Health (NDDH) Licensed Asbestos Inspector and Lead Risk Assessor. The work was completed to meet the following objectives:
Identify friable and non-friable asbestos-containing materials (ACM) at the Project
Area as defined by the Environmental Protection Agency (EPA) and the NDDH.
Identify regulated ACM (friable or non-friable) at the Project Area that could become friable during renovation activities, and according the current State and Federal regulations, would require abatement prior to building renovation.
Identify surfaces that contain lead-based paint in poor condition that should be stabilized prior to renovation activities using a Niton XL X-Ray Fluorescence (XRF) analyzer.
1.2 DEFINITIONS
The EPA and the NDDH define ACM as any material that contains greater than one percent asbestos. Materials found to contain one percent or less asbestos are not regulated as ACM.
Friable ACM is defined as any material that contains greater than one percent asbestos, and which can be crumbled, pulverized, or reduced to powder by hand pressure.
Limited LBP and Asbestos Survey – Peer #21835.00 2
Category I non-friable ACM means asbestos-containing packings, gaskets, resilient floor covering, and asphalt roofing products containing more than one percent asbestos. Category I non-friable ACM is not allowed to remain in place during renovation if it is in a condition where the renovation activities might cause it to become friable.
Category II non-friable ACM means any material, excluding Category I non-friable ACM, containing more than one percent asbestos that, when dry, cannot be crumbled, pulverized, or reduced to a powder by hand pressure. Category II non-friable ACM is not allowed to remain in place during renovation if it has a high probability of becoming crumbled, pulverized, or reduced to a powder during demolition, transport, or disposal.
2.0 ASBESTOS
2.1 OVERVIEW
The asbestos evaluation portion of the Work consisted of a walk-through reconnaissance to identify suspect ACM within the Project Area. All areas of the Project Area, identified by the Client, were accessed during the reconnaissance. Areas outside of the Project Area were not inspected, unless otherwise instructed. Limitations to this survey have been detailed in Section 2.6.
For the purpose of the Work, the entire Project Area as defined in this report was considered to be one functional area as defined by the Asbestos Hazard Emergency Response Act (AHERA). Upon completion of the reconnaissance, the suspect ACM was inventoried, assessed, and sampled for laboratory analysis.
2.2 PREVIOUS ASBESTOS SURVEY
Peer conducted a previous asbestos survey within Building 314, the results of which are detailed in a report Non-destructive Lead-based Paint & Asbestos Survey, Grand Forks Air Force Base, JFSD 200909 – Part of Building 314, Grand Forks, North Dakota, and dated November 20, 2009 (the 2009 Survey). The 2009 Survey focused primarily on the suspended ceiling and heating, ventilation and air conditioning (HVAC) system throughout the office space, a mechanical room, and adjoining hallways (the Project Area) of Building 314. A copy of the 2009 Survey is on file at Peer and available (per request).
Limited LBP and Asbestos Survey – Peer #21835.00 3
2.3 SUSPECT ACM TARGETED FOR SAMPLING
Non-Suspect Material
The following materials were determined to be non-suspect ACM and were not targeted for sampling during this assessment:
Concrete, Wood, Metal, Glass, Plastic, and Fiberglass.
Suspect Materials
Suspect ACM identified and subsequently sampled in the Project Area included:
Three types of suspended acoustical ceiling tile;
Various types of resilient floor tile and associated mastics;
Gypsum wallboard with tape and joint compound;
Various types of carpet mastic;
Various types of vinyl base trim and associated mastics;
Various ceramic tile, grout, and bedding;
Thermal system insulations;
Various types of caulking; and Various roofing materials.
Sample Analysis
A total of 35 bulk samples were submitted for laboratory analysis. Some of the bulk samples consisted of several layers. A total of 61 samples (including layers) were analyzed using polarized light microscopy (PLM) in accordance with EPA analytical protocol {EPA-600 R93/116} by EMSL Analytical, Inc. of Plymouth, Minnesota. Materials that were analyzed and found to contain one percent or less asbestos are considered “non-asbestos” per current State and Federal regulations. Materials that were found to contain greater than one percent asbestos are considered to be ACM.
Under current Federal regulations, if the PLM results detect asbestos at a concentration of less than 10% in one or more of the samples from any sample unit, the owner or operator of the building may (1) elect to assume the amount to be greater than 1% and treat the material as ACM or (2) require verification of the amount by utilizing the Point-Count Method. If the Point-Count Method analysis determines that the concentration of asbestos is greater than one percent, the material will be determined to be regulated ACM. If the Point-Count Method analysis determines that the concentration of asbestos is one percent or less, the material will be determined to be unregulated and non-asbestos containing.
Limited LBP and Asbestos Survey – Peer #21835.00 4
No samples, collected during this assessment, were submitted for analysis using the Point- Count Method.
Most of the sampled building materials were observed to be in good condition. A few of the materials (e.g. some floor tile, thermal system insulation) were observed to be in damaged condition. A copy of the analytical laboratory report is included as Appendix
A. An Asbestos Summary Table is included in Appendix B. Sample location diagrams are included as Appendix C.
2.4 ACM TESTING RESULTS
Friable ACM (Confirmed by Sampling and Analysis)
None of the sampled building materials were determined to be friable ACM.
Non-Friable ACM (Confirmed by Sampling and Analysis)
The following materials sampled from the building were determined to be non-friable ACM based on the definitions provided in current State and Federal regulations:
Black roof membrane and gray seam compound (seam compound only) located on
“Area A” of the roofing (sample 314-29), approximately 3,765 square feet. This material is considered to be Category I non-friable ACM.
Gray/black mortar/caulking located along the top edge of the east flashing of “Area A” roofing (sample 314-30), approximately 100 linear feet. This material is considered to be Category I non-friable ACM.
Black ridge foam and coating (black coating only) located on the central roof ridge of “Area A” roofing (sample 314-31), approximately 40 linear feet. This material is considered to be Category I non-friable ACM.
Black roof membrane and gray seam compound (seam compound only) located on “Area A” of the roofing (sample 314-32), approximately 3,765 square feet. This material is considered to be Category I non-friable ACM.
Black roof membrane and gray seam compound (seam compound only) located on “Area B” of the roofing (sample 314-33), approximately 9,760 square feet. This material is considered to be Category I non-friable ACM.
ACM (Assumed)
Any suspect building materials that were not sampled, should be assumed to be ACM unless testing proves otherwise.
Limited LBP and Asbestos Survey – Peer #21835.00 5
Non-ACM (Confirmed by Sampling and Analysis)
Building materials sampled from the structure which were determined to be non-ACM based on the definitions provided in current State and Federal regulations are presented in Appendix A. See Appendix B for specific locations.
2.5 LIMITATIONS
Assessment and observations were limited to the prescribed Project Areas. All areas to be affected by future renovation, as described by the Client, were accessed during the Work. Destructive testing was not conducted within office spaces within the Project Area which were occupied by GFAFB personnel. Also, destructive testing was not conducted on the roofing of the Project Area so as to maintain the integrity of the roofing system(s).
3.0 LEAD-BASED PAINT
3.1 OVERVIEW
Limited testing and observations for lead-based paint was conducted throughout the Project Area. The observations were limited to painted surfaces that were in poor condition and that, if determined to be lead-based paint, would require stabilization prior to renovation (e.g., lead that that is not attached to the substrate must be managed/disposed in accordance with applicable hazardous waste and/or solid waste rules and regulations and cannot be managed as normal demolition material).
Based on current regulatory definitions, lead-based paint is defined as paint containing lead concentrations equal to or greater than 1.0 milligrams per square centimeter (mg/cm2) when using a Niton XL X-ray fluorescence (XRF) analyzer. The XRF provides the measured lead concentration in weight of lead per unit area.
3.2 RESULTS
Limited testing for lead-based paint was conducted on painted, glazed or stained surfaces observed to be in poor condition. Coated surfaces observed to be in poor condition included the exterior block walls, and the brown overhead door bumper guards located in the maintenance area. All other painted, glazed, or stained surfaced were intact at the time of the inspection. Based on the results of the testing, lead-based paint was identified on the brown metal bumper guards in and around the maintenance area.
Limited LBP and Asbestos Survey – Peer #21835.00 6
A copy of the lead-based paint testing results is included in Appendix D. A diagram depicting the test locations is included as Appendix E.
3.3 LIMITATIONS
The observations and testing conducted were not intended to represent a comprehensive survey of all painted surfaces and was not intended to represent regulated lead work as defined by the NDDH.
4.0 HAZARDOUS MATERIALS
Identification and inventory of potential hazardous materials or materials that have special disposal requirements which should be removed prior to renovation activities was not specified under the scope of work for this project. As such, hazardous materials, other than asbestos or lead-based paint, may be present in the Project Area and should be removed and disposed of appropriately prior to renovation activities.
5.0 CONCLUSIONS AND RECOMMENDATIONS
Asbestos-Containing Materials
Based on the results of the asbestos survey, no materials were determined or assumed to be ACM within the Project Area.
The following recommendations are provided based on the results of the asbestos survey:
Any unidentified suspect materials that may be encountered in the future should be assumed to contain asbestos until they are sampled and analyzed. The asbestos survey work must be completed by a licensed asbestos building inspector.
Due to the limitations in sampling suspect ACM (i.e. roofing), it is recommended that a licensed asbestos inspector and/or a licensed asbestos abatement contractor be available or present during renovation, remodeling, or demolition activities to sample and/or remove any unidentified or suspect ACM encountered during these activities.
This inspection only assessed only “portions” of Building 314. If work is done outside the prescribed Project Area, additional inspection within those areas should be completed.
Limited LBP and Asbestos Survey – Peer #21835.00 7
Lead-Based Paints
The following recommendations are provided based on the results of the limited lead testing:
Based on the results of the limited testing, lead-based paint was identified on the brown metal bumper posts located in the maintenance facility portion of the Project area.
This inspection only assessed portions of Building 314. If work is done outside the Project Area, additional inspection for those areas should be completed.
Hazardous Materials
Since hazardous materials were not inventoried during the performance of the Work, there is the potential that hazardous materials, other than asbestos and lead-based paint, will be encountered during remodeling activities. Such materials should be appropriately removed and disposed of prior to remodeling activities.
6.0 SUMMARY OF QUALIFICATIONS
A summary of corporate and individual qualifications for Peer and the individuals associated with this project is included in Appendix G.
Prepared by:
Jason A. Gelling Environmental Professional
NDDH Certified Asbestos Inspector/Mgmt Planner No.: 2723/4563 NDDH Certified Lead Risk Assessor No.: 173
Building 314
BUILDING LOCATION NOV. 2011
BUILDING 314
GRAND FORKS AIR FORCE BASE
GRAND FORKS, NORTH DAKOTA
FIGURE
2PROJECT # 2183521835\21835 FIGURE 2.mxd
0 700350 Feet
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-1-Floor Tile
351106728-0001
Rm 147-brown
12x12 parquet-look f.t & mastic
Brown/Tan None Detected
Non-Fibrous
Heterogeneous
Synthetic5% Non-fibrous (other)95%
314-1-Mastic
351106728-0001A
Rm 147-brown
12x12 parquet-look f.t & mastic
Beige/Clear None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-2-Floor Tile
351106728-0002
Rm 147-gray
12x12 w/streaks f.t
& mastic
Gray None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-2-Mastic
351106728-0002A
Rm 147-gray
12x12 w/streaks f.t
& mastic
Tan None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-3-Base Trim
351106728-0003
Rm 147-gray 4" vinyl base trim & mastic
Gray None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-3-Mastic
351106728-0003A
Rm 147-gray 4" vinyl base trim & mastic
Cream None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
Initial report from 11/07/2011 13:18:46 mailto:minneapolislab@emsl.com
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-4
351106728-0004
Rm 147-white textured, flush 2x2 acoustic ceiling
White None Detected
Fibrous
Heterogeneous
Min. Wool90% Non-fibrous (other)10%
314-5-Tan Mastic
351106728-0005
Rm 147-tan f.t & mastic (bottom layer)
Tan None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
314-5-Floor Tile
351106728-0005A
Rm 147-tan f.t & mastic (bottom layer)
Tan None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-5-Black Mastic
351106728-0005B
Rm 147-tan f.t & mastic (bottom layer)
Black None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
314-6
351106728-0006
Rm 147-sheetrock wall-above dropped ceiling
Tan/White None Detected
Fibrous
Heterogeneous
Cellulose10%
Glass2%
Non-fibrous (other)88%
314-7
351106728-0007
Rm147a-yellow/tan carpet mastic
Tan/Yellow None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-8
351106728-0008
Hall near Rm 146-
2x2 white dropped style acoustic
White None Detected
Fibrous
Heterogeneous
Min. Wool90% Non-fibrous (other)10%
314-9-Floor Tile
351106728-0009
Rm 150-tan f.t. & mastic (bottom layer)
Tan None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-9-Mastic
351106728-0009A
Rm 150-tan f.t. & mastic (bottom layer)
Black None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
314-9-Gray Layer
351106728-0009B
Rm 150-tan f.t. & mastic (bottom layer)
Gray None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-10-Floor Tile
351106728-0010
Rm 150-gray
12x12 w/streaks f.t
& black mastic
Gray None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-10-Mastic
351106728-0010A
Rm 150-gray
12x12 w/streaks f.t
& black mastic
Tan/Yellow None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-11-Floor Tile
351106728-0011 gray 12x12 w/streaks f.t & black mastic
Gray None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-11-Mastic
351106728-0011A gray 12x12 w/streaks f.t & black mastic
Black None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-12-Ceramic Tile
351106728-0012
6" tan ceramic tile
& bedding & grout
(NE entrance
Brown/Gray None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-12-Gray Layer
351106728-0012A
6" tan ceramic tile
& bedding & grout
(NE entrance
Gray None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
314-13-Carpet
351106728-0013
Rm 112 (Snacks) gray carpet & yellow masitc
Gray None Detected
Fibrous
Heterogeneous
Synthetic85% Non-fibrous (other)15%
314-13-Mastic
351106728-0013A
Rm 112 (Snacks) gray carpet & yellow masitc
Tan/Yellow None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-14-Floor Tile
351106728-0014
Rm 121
(Womens) tan
12x12 f.t w/streaks
& mastic
Tan None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-14-Mastic
351106728-0014A
Rm 121
(Womens) tan
12x12 f.t w/streaks
& mastic
Tan/Yellow None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
314-15-Base Trim
351106728-0015
Rm 121
(Womens) Rose
4" Vinyl base trim
& mastic
Red None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-15-Mastic
351106728-0015A
Rm 121
(Womens) Rose
4" Vinyl base trim
& mastic
White None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-16-Ceramic Tile
351106728-0016
Rm 129 (Men's)
Gray 1" Ceramic f.t & grout & masti
Gray None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-16-Grout
351106728-0016A
Rm 129 (Men's)
Gray 1" Ceramic f.t & grout & masti
Gray None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-16-Mastic
351106728-0016B
Rm 129 (Men's)
Gray 1" Ceramic f.t & grout & masti
Cream None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-17-Carpet
351106728-0017
Rm 112 (Snacks) brown wall carpet
& mastic & sheet
Gray None Detected
Fibrous
Heterogeneous
Synthetic95% Non-fibrous (other)5%
314-17-Mastic
351106728-0017A
Rm 112 (Snacks) brown wall carpet
& mastic & sheet
White None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-17-Sheetrock
351106728-0017B
Rm 112 (Snacks) brown wall carpet
& mastic & sheet
Tan/White None Detected
Sheetrock and Joint Compound composited
Fibrous
Heterogeneous
Cellulose10% Non-fibrous (other)90%
314-18
351106728-0018
Joint Compound & tape & sheetrock
(North hallway i
Tan/White None Detected
Sheetrock, Tape and Joint Compound composited
Fibrous
Heterogeneous
Cellulose10%
Glass3%
Non-fibrous (other)87%
314-19
351106728-0019 green sealant above plenum in north hallway
Green None Detected
Non-Fibrous
Heterogeneous
Glass3% Non-fibrous (other)97%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-20
351106728-0020
Rm 178-yellow carpet mastic
Tan/Yellow None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
314-21-Base Trim
351106728-0021
Rm 190-black vinyl base trim & mastic
Black None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-21-Mastic
351106728-0021A
Rm 190-black vinyl base trim & mastic
Brown None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-22-Tread
351106728-0022
Mezzanine-brown vinyl step treads & mastic
Brown None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-22-Mastic
351106728-0022A
Mezzanine-brown vinyl step treads & mastic
Brown None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
314-23-Floor Tile
351106728-0023
Mezzanine-yellow
12x12 ft & mastic
Yellow/Beige None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-23-Mastic
351106728-0023A
Mezzanine-yellow
12x12 ft & mastic
Brown None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-24
351106728-0024
Mezzanine-white textured 2x4 acoustic tiles
Tan/White None Detected
Fibrous
Heterogeneous
Min. Wool40%
Cellulose25%
Non-fibrous (other)15%
Perlite20%
314-25-Base Trim
351106728-0025
Mezzanine-Brown vinyl base trim & brown mastic
Brown None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-25-Mastic
351106728-0025A
Mezzanine-Brown vinyl base trim & brown mastic
Brown None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
314-26
351106728-0026
Mezzanine-
Sheetrock & Mud
Tan/White None Detected
Sheetrock and Joint Compound composited
Fibrous
Heterogeneous
Cellulose10% Non-fibrous (other)90%
314-27
351106728-0027
Mezzanine-Carpet
Mastic on Walls-white
White None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-28
351106728-0028
Mezzanine-fiberglass TSI w/white paper face
White/Yellow None Detected
Non-Fibrous
Heterogeneous
Cellulose5%
Glass90%
Non-fibrous (other)5%
314-29-Membrane
351106728-0029
Area A-roof-black asphalt membrane w/gray seam com
Black None Detected
Fibrous
Heterogeneous
Cellulose35% Non-fibrous (other)65%
314-29-Seam
Compound
351106728-0029A
Area A-roof-black asphalt membrane w/gray seam com
Gray/Black
Fibrous
Heterogeneous
Chrysotile8%Non-fibrous (other)92%
314-30
351106728-0030
Area A-gray black mortar top edge of flashing
Tan/White
Fibrous
Heterogeneous
Chrysotile5%Non-fibrous (other)95%
314-31-Gray Layer
351106728-0031
Area A-black ridge foam & coating
Gray/Black
Fibrous
Heterogeneous
Chrysotile5%Cellulose5% Non-fibrous (other)90%
314-31-Foam Layer
351106728-0031A
Area A-black ridge foam & coating
Black None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-32-Membrane
351106728-0032
Area A-black asphalt membrane w/gray seam compound
Black None Detected
Fibrous
Heterogeneous
Cellulose35% Non-fibrous (other)65%
314-32-Seam
Compound
351106728-0032A
Area A-black asphalt membrane w/gray seam compound
Gray/Black
Fibrous
Heterogeneous
Chrysotile10%Non-fibrous (other)90%
314-33-Membrane
351106728-0033
Area B-black asphalt membrane w/blk/gray compound
Black None Detected
Fibrous
Heterogeneous
Cellulose35% Non-fibrous (other)65%
314-33-Gray Layer
351106728-0033A
Area B-black asphalt membrane w/blk/gray compound
Gray/Black
Fibrous
Heterogeneous
Chrysotile10%Non-fibrous (other)90%
314-34
351106728-0034
Area C-black asphalt tan sealant
Black None Detected
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
314-35-Membrane
351106728-0035
Area D-black rubber membrane
& black tar
Black None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
351106728
Attn: Jason Gelling Peer Engineering, Inc.
819 30th Avenue South Suite 202 Moorhead, MN 56560
Customer PO:
Received: 11/04/11 9:30 AM
21835; Building 314 at GFAFB
Customer ID: PEER78
Fax: Phone: (218) 477-6060
Project:
EMSL Order:
EMSL Proj:
11/7/2011Analysis Date:
EMSL Analytical, Inc.
14375 23rd Avenue North, Minneapolis, Mn 55447 Phone: (763) 449-4922 Fax: (763) 449-4924 Email: minneapolislab@emsl.com
314-35-Tar Layer
351106728-0035A
Area D-black rubber membrane
& black tar
Black None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
Rachel Travis, Laboratory Manager or other approved signatory
Analyst(s)
THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.23.0 Printed: 11/7/2011 1:18:46 PM
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request.
Samples analyzed by EMSL Analytical, Inc. Minneapolis, Mn NVLAP Lab Code 200019-0
Mark Erickson (61)
Appendix B Asbestos Sample Summary Table
Building 314 Peer Project #21835.00
November 2011
SUSPECT MATERIAL LOCATION
% ASBESTOS
ANALYTICAL
RESULTS
SAMPLE
REFERENCE
NUMBER
FRIABLE
(F)/NON-
FRIABLE
(NF) QUANTITY
Brown 12x12 parquet floor tile, mastic Rm 147 ND (tile)
ND (mastic)
314-1 NA NA
Gray 12x12 with streaks floor tile, mastic Rm 147 + throughout ND (tile)
ND (mastic)
314-2 NA NA
Gray 4" vinyl base trim, mastic Rm 147 + throughout ND (trim)
ND (mastic)
314-3 NA NA
White textured flush 2x2 ceiling tile Rm 147 + throughout offices ND 314-4 NA NA
Tan floor tile, mastic (bottom layer) Rm 147
ND (mastic)
ND (tile)
ND (mastic)
314-5 NA NA
Sheetrock wall above dropped ceiling Rm 147 ND 314-6 NA NA
Yellow/tan carpet mastic Rm 147a ND 314-7 NA NA
White dropped style 2x2 ceiling tile Throughout Hallways ND 314-8 NA NA
Tan floor tile, mastic (bottom layer) Rm 150
ND (tile)
ND (mastic)
ND (gray layer)
314-9 NA NA
Gray 12x12 with streaks floor tile, mastic Rm 150 + throughout ND (tile)
ND (mastic)
314-10 NA NA
Gray 12x12 with streaks floor tile, mastic Throughout Hallways ND (tile)
ND (mastic)
314-11 NA NA
Tan 6" ceramic tile, bedding/grout NE Entrance ND (tile)
ND (grout)
314-12 NA NA
Gray carpeting with mastic Rm 112 + throughout ND (carpet)
ND (mastic)
314-13 NA NA
Tan 12x12 with streaks floor tile, mastic Rm 121, women's bathroom ND (tile)
ND (mastic)
314-14 NA NA
Rose 4" vinyl base trim, mastic Rm 121, women's bathroom ND (trim)
ND (mastic)
314-15 NA NA
Gray 1" ceramic tile, grout, bedding Rm 129, men's bathroom
ND (tile)
ND (grout)
ND (mastic)
314-16 NA NA
Brown wall carpet, mastic, sheetrock Rm 112 + throughout
ND (carpet)
ND (mastic)
ND (sheetrock)
314-17 NA NA
Joint compound, tape, mud Throughout ND 314-18 NA NA
Green fire stop sealant Underside of roof decking and wall penetrations
ND 314-19 NA NA
Yellow carpet mastic Rm 178 + throughout ND 314-20 NA NA
Black vinly base trim, mastic Rm 190 ND (trim)
ND (mastic)
314-21 NA NA
Brown stair tread/kicker vinyl Mezzanine Area ND (vinyl)
ND (mastic)
314-22 NA NA
Yellow 12x12 floor tile, mastic Mezzanine Area ND (tile)
ND (mastic)
314-23 NA NA
White textured 2x4 ceiling tile Mezzanine Area ND 314-24 NA NA
Brown vinyl base trim, mastic Mezzanine Area ND (trim)
ND (mastic)
314-25 NA NA
Sheetrock and joint compound Mezzanine Area ND 314-26 NA NA White wall carpet mastic Mezzanine Area ND 314-27 NA NA
White fiberlass thermal system insulation Mezzanine Area ND 314-28 NA NA
Black roof Membrane and gray seam compound "Area A", roofing
ND (membrane)
8% Chrysotile
(seam compound)
314-29
NF -
Category I
Approx.
3,765 SF
Gray/black mortar, caulking "Area A", roofing, top edge of flashing, adjacent to "Area B" 5% Chrysotile 314-30
NF -
Category I
Approx. 100
LF
Black ridge foam and coating "Area A", roofing
5% Chrysotile
(black layer)
ND (foam layer)
314-31
NF -
Category I
Approx. 40
LF
Black roof Membrane and gray seam compound "Area A", roofing
ND (membrane)
10% Chrysotile
(seam compound)
314-32
NF -
Category I
Approx.
3,765 SF
Black roof Membrane and gray seam compound "Area B", roofing
ND (membrane)
10% Chrysotile
(seam compound)
314-33
NF -
Category I
Approx.
9,760 SF
Black asphalt tar sealant "Area C", roofing ND 314-34 NA NA
Black membrane and tar "Area D/E", roofing ND (membrane)
ND (tar)
314-35 NA NA
ASBESTOS SUMMARY TABLE - BUILDING 314
ND - Not detected at or above the laboratory detection limits.
SF - Square Feet.
LF - Linear Feet. Page 1 of 1
Appendix D
LBP Testing Results
GFAFB - Building 314
Grand Forks AFB, ND
November 2011
Reading No Time Type Duration Units Sequence COMPONENT SUBSTRATE SIDE CONDITION COLOR SITE INSPECTOR FLOOR ROOM MISC1 Results Depth Index Action Level PbC PbC Error PbL PbL Error PbK PbK Error
1 11/2/2011 14:52 SHUTTER_CAL 70.51 cps Final Verification 1.04 JAG 4.64 0 0.76 0 0.03 0
2 11/2/2011 14:53 PAINT 24.65 mg / cm ^2 Final Verification 1.04 JAG Positive 1.12 1 1.1 0.1 1.1 0.1 0.8 0.3
3 11/2/2011 14:54 PAINT 23.66 mg / cm ^2 Final Verification 1.04 JAG Positive 1.08 1 1 0.1 1 0.1 0.7 0.3
4 11/2/2011 14:54 PAINT 22.37 mg / cm ^2 Final Verification 1.04 JAG Positive 1.06 1 1 0.1 1 0.1 0.9 0.3
5 11/2/2011 14:55 PAINT 2.64 mg / cm ^2 Final Wall Concrete A Poor Tan GFAFB JAG 1 Exterior Negative 1 1 0 0.02 0 0.02 < LOD 0
6 11/2/2011 14:56 PAINT 1.31 mg / cm ^2 Final Wall Concrete A Poor Tan GFAFB JAG 1 Exterior Negative 1 1 0 0.02 0 0.02 0.25 1.44
7 11/2/2011 14:57 PAINT 0.87 mg / cm ^2 Final Wall Steel A Poor Brown/Yellow/Red GFAFB JAG 1 Exterior Bollard Positive 2.38 1 2.6 1.6 2.6 1.6 5.6 5.7
10 11/2/2011 15:00 PAINT 21.07 mg / cm ^2 Final Verification 1.04 JAG Positive 1.12 1 1 0.1 1 0.1 0.4 0.3
11 11/2/2011 15:01 PAINT 22.42 mg / cm ^2 Final Verification 1.04 JAG Positive 1.11 1 1 0.1 1 0.1 0.4 0.3
12 11/2/2011 15:02 PAINT 24.16 mg / cm ^2 Final Verification 1.04 JAG Positive 1.09 1 1 0.1 1 0.1 0.4 0.3
QUALIFICATIONS AND EXPERIENCE
Peer was incorporated in the State of Minnesota in March 1991. The company is owned and operated by Stephen T. Jansen, M.S., P.G., and Kenneth A. Larsen, P.E., P.G. Peer is a highly specialized engineering company providing a full range of services including, but not limited to, Phase I Environmental Site Assessments; asbestos, lead based paint and other hazardous materials identification and abatement supervision; radon measurement and mitigation design;
underground storage tank identification, abandonment and removal supervision; operations and maintenance (O&M) program development; and soil and groundwater contamination assessment and remediation.
Since our incorporation in 1991, Peer has specialized in providing services to local government, industry, lenders, attorneys, private landowners and others. Peer has completed Phase I Environmental Site assessments of all types of properties including undeveloped, agricultural, single family, multi-family, and commercial office, retail and industrial. Peer has conducted hydrogeologic investigations/studies, and soil/water quality assessments at hundreds of sites located in a vast array of geographical and environmental settings.
Peer has a highly integrated, multi-disciplinary staff of professionals. Peer has completed hundreds of Phase I Environmental Site Assessments of properties using scopes of work designed by HUD, Fannie Mae, Freddie Mac and numerous other lending entities.
Our professional staff includes several licensed engineers and geologists, a hydrogeologist and chemist, a soil/materials scientist, a GIS/computer specialist, and sampling technicians who design, perform and directly oversee our projects. Our personnel are licensed as asbestos inspectors, asbestos management planners, lead paint inspectors and lead risk assessors. All technical personnel have completed OSHA 40 hour health and safety training with 8 hour annual refresher courses.
Peer’s corporate office is located in Eden Prairie, Minnesota. We have 15 full-time employees.
Thirteen are professionals with education, post-graduate training and experience directly related to the environmental field. Two employees are administrative support staff. Being relatively smaller in size, Peer is able to respond quickly to our client’s site specific individual needs, yet still provide cost-effective “big picture” services. Our clients also receive direct attention/input from Peer’s owners and principals, so there are no unforeseen surprises at the end of the project.
QUALIFICATIONS AND EXPERIENCE
SERVICES OVERVIEW
Property Transaction
• Phase I & Phase II Environmental Site Assessments
• Regulatory Assurance Letters
• Property Condition Assessments
• Appraisal Support
• Geotechnical Evaluation
Soil and/or Groundwater Sampling and Remediation
• Risk-Based Cleanup Design
• Cleanup Grant Preparation & Administration
• Petroleum Cleanup Reimbursement
• Regulatory Approvals & Assurance Letters
• Environmental Permits
• Remediation Plans & Specifications
• Remediation & Construction Management
• General Contracting
• Turnkey Remediation
Compliance
• RCRA Permitting & Closure
• Compliance Audits
• Waste Characterization & Disposal
• Petroleum & Chemical Storage Tank System Design
• NPDES Stormwater Permits & Pollution Prevention Plans
• Wastewater Discharge Permits
• Stormwater, Wastewater, & Groundwater Monitoring
Building Demolition & Decontamination
• Asbestos & Lead Paint Surveys
• Hazardous Materials Inventories (electrical equipment, refrigerants)
• Building Contaminant Assessment (PCBs, mercury, mold)
• Abatement Alternative Analysis
• Abatement Plans & Specifications
• Abatement Contractor Management
• Turnkey Abatement
JASON A. GELLING
SR. PROJECT MANAGER
EDUCATION
Bachelor of Science Degree in Environmental Geology and Technology, 1997, University of North Dakota, Grand Forks, North Dakota.
Continuing education in AHERA asbestos building inspection, HUD Lead Risk Assessment, ASTM Phase I/II Environmental Site Assessments, project management, and Hazardous Waste Operations
REGISTRATIONS/CERTIFICATIONS
Certified Asbestos Inspector, Minnesota Certified…