Attach_2 Submittal Schedule_Revised Amendment 2.pdf

PDF 280 KB Posted

Attached to
Repair E-01 MAF Water Well Federal contract opportunity
Solicitation number
FA4626-20-R-0006
Issued by
Department of the Air Force Global Strike Command

About this file

This document is a submittal schedule for a solicitation to repair E-01 MAF's domestic water well system at Malmstrom Air Force Base in Montana. The project includes abandoning and replacing an existing domestic water well, installing a new water treatment system, new wastewater handling equipment, and all related electrical and control systems. The estimated value is between $500,000 and $1,000,000. The NAICS code is 237110 for Water and Sewer Line and Related Structures Construction, and the small business size standard is $36,500,000. Funds have not been allocated for this contract yet. The submittal schedule outlines 192 required technical submittals from contractors organized by division and item, specifying submission deadlines and review processes. Information on products, drawings, test results, qualifications, permits, manuals and more are detailed.

View the file

Other files for this federal contract opportunity

Other files attached to Repair E-01 MAF Water Well, newest first.
File Type Posted
Holiday Week Notice & Contact Information.pdf PDF
Solicitation Amendment #3 FA462620R00060003 SF 30.pdf PDF
Summary of Changes -- Amendment #3.pdf PDF
Solicitation Amendment #3 - FA462620R00060003.pdf PDF
Q&A #3.pdf PDF
Attach_4 Project Drawings NZAS 16-6006 Revised Amendment 2.pdf PDF
Attach_1 Specifications NZAS 16-6006_Revised Amendment 2.pdf PDF
Summary of Changes -- Amendment 2.pdf PDF
FA462620R0006 Amendment #2.pdf PDF
Q&A #2.pdf PDF
Attach_10 Section L ITO Amendment #1.docx DOCX document
Solicitation Amendment FA462620R00060001 SF 30.pdf PDF
Summary of Changes - Amendment 1.docx DOCX document
Q&A.docx DOCX document
Solicitation - FA462620R0006.pdf PDF
Attach_3 Schedule of Drawings.pdf PDF
Attach_2 Submittal Schedule.pdf PDF
Attach_6 Installation Perimeter Access Control.pdf PDF
Attach_5 Applicable DoL Wage Determinations.pdf PDF
Attach_9 Subcontractor Consent.doc DOC document
Attach_4 Project Drawings NZAS 16-6006.pdf PDF
Attach_7 Special Contract Requirements.pdf PDF
Attach_1 Specifications NZAS 16-6006.pdf PDF
Attach_10 Section L ITO New.docx DOCX document
Attach_8 Past Performance Questionnaire.docx DOCX document
Attach_11 Section M BVT2.docx DOCX document
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MALMSTROM AFB, MONTANA

SCHEDULE OF MATERIALS SUBMITTALS Project Number Project Title: Solicitation/Contract No.

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

O F

C

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E R

'S

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

W A

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

IN

G

S

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

IO

N

D

T

B Y

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D I

N T

R A

C T

IN

G

D A

T E

T O

C

IV

IL

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

L

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

DIVISION 01 - GENERAL REQUIREMENTS

01 00 00 General Requirements - 1.8.1 Contractor Design Drawings 3

30d

PTSW

01 00 00 General Requirements - 1.8.1 Shop Drawings 3

30d

PTSW

01 00 00 General Requirements - 1.8.1 Final As-Built Drawings 3 45d - AFI

01 00 00 General Requirements - 3.3.1 Schedule of Materials

Submittal

10 d -

ANP

01 00 00 General Requirements - 3.4.1 Manufacturer's Product

Brochures & Catalog Data, Components and Materials to be Installed

30d -

PTSW

01 00 00 General Requirements - 3.6.4 Overall Project Schedule 3

30d -

PTSW

01 00 00 General Requirements - 3.8.1 Start of Work Notification 3 5 d - PTE

01 00 00 General Requirements - 3.11 Utility Outages 3 10d - PTE

01 00 00 General Requirements - 3.13 Quality Control Plan and

Specified Quality Control Submittals

10d -

ANP

01 00 00 General Requirements - 3.16 As-Built Field Data 3 30d - AFI

01 00 00 General Requirements - 3.16.4 &3.16.5 As-Built Field

Drawings 4 30d - AFI AutoCAD CD

12 01 00 00 General Requirements - 3.17 O&M Instructions/Manual 5

4 20d -

AFI; 1

10d -

PTFI

1 hardcopy, 2 CD's

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-1

REQUIRED TECHNICAL SUBMITTALS

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

01 00 00 General Requirements - 3.20.3 Size of Storage Area

Requested

30d -

PTSW

01 00 00 General Requirements - 3.23.1 Work Clearance Request (AF

Form 103)

14d -

PTSW

AF Form 103 Work Clearance

01 00 00 General Requirements - 3.26 Nuclear Densometers 3

30d -

PTSW

16 01 00 00 General Requirements - 3.28 Notice of Final Inspection 3 14d - PTE

Red line “As-Built” dwgs shall be provided by the Contractor at final inspection.

01 10 00 Site Security - 1.3 Contractor Entry Authorization List

(CEAL)

14d -

PTSW

EAL

01 10 00 Site Security - 1.8.3 Weekly Entry and Exit Times 1 7d - AE

01 36 00 Environmental Protection - 1.2.3 Copies of Environmental

Permits 3 5d - AE

01 36 00 Environmental Protection - 1.8.1 List of Hazardous

Materials (1360-5) with MSDSs

30d -

PTSW

01 36 00 Environmental Protection - 1.8.1.2 af Form 3952

"Authorization Request Worksheets"

14d -

PTSW

01 36 00 Environmental Protection - 1.8.1.4 Actual Hazardous

Materials Used 3 30d - AFI

01 36 00 Environmental Protection - 1.11.6 Waste Management Plan 3

10d -

PTFI

01 36 00 Environmental Protection - 1.12.5 Recycled Material Use

Report

10d -

PTFI

25 01 73 29 Cutting and Patching - 1.4 Cutting and Patching Proposal 3 15d - PTE

01 73 29 Cutting and Patching - 2.1 Patching Material Product Data 3

30d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-2

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

DIVISION 03 - CONCRETE

27 03 30 00 Cast-in-Place Concrete - 1.2A Shop Drawings 3 30d -

PTSW

28 03 30 00 Cast-in-Place Concrete - 1.2B Concrete Mix Design Data 3 30d -

PTSW

29 3 30 00 Cast-in-Place Concrete - 1.2C Test Reports 3 7d & 28d -

ATT

30 3 30 00 Cast-in-Place Concrete - 1.2D Certificates 3 30d -

PTSW

31 3 30 00 Cast-in-Place Concrete - 1.3B Installation Plan 3 30d -

PTSW

DIVISION 05 - METALS

05 05 23 Metal Fastenings - 1.2A Procedure Specifications and

Procedure Qualification Test Results 5 7d - ATT

05 05 23 Metal Fastenings - 1.2B Performance Qualifications of

Welders and Welding Officers

30d -

PTSW

34 05 05 23 Metal Fastenings - 1.2C Welder's Certificates 3 30d -

PTSW

35 05 05 23 Metal Fastenings - 1.2E Welder's Record 3 30d - AFI

36 05 05 23 Metal Fastenings - 2.1 Electrodes Product Data 3 30d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-3

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

37 05 05 23 Metal Fastenings - 2.2 Stainless Steel Fastener Product Data 3 30d -

PTSW

DIVISION 09 - PAINT

38 09 90 00 Paints and Coatings - 1.2 Shop Drawings 3 30d -

PTSW

39 09 90 00 Paints and Coatings - 1.2 Product Certification 3 30d -

PTSW

40 9 90 00 Paints and Coatings - 1.2 Product Materials 3 30d -

PTSW

41 9 90 00 Paints and Coatings - 1.2 Manufacturer Tech Sheet 3 30d -

PTSW

42 9 90 00 Paints and Coatings - 1.2 Color Samples 3 30d -

PTSW

43 09 90 00 Paints and Coatings - 1.2 Certificates 3 30d -

PTSW

44 9 90 00 Paints and Coatings - 1.2 Application Instructions 3 30d -

PTSW

45 9 90 00 Paints and Coatings - 1.2 Manufacturer's Safety Data Sheets 3 30d -

PTSW

46 9 90 00 Paints and Coatings - 1.2 Closeout Submittals 3 30d - AFI

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-4

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

47 09 90 00 Paints and Coatings - 1.3 Qualifications Data 3 30d -

PTSW

DIVISION 22 - PLUMBING

22 05 53 Identification for Plumbing Piping and Equipment - 1.2 Pipe

Label Samples for Color, Letter Style, and Graphic Representation

30d -

PTSW

22 05 53 Identification for Plumbing Piping and Equipment - 2.1 Pipe

Label Product Data

30d -

PTSW

22 11 00 Facility Water Distribution - 1.1A Detailed Plans of

Departure from this Section

45d -

PTSW

51 22 11 00 Facility Water Distribution - 1.2 Shop Drawings 3 30d -

PTSW

52 22 11 00 Facility Water Distribution - 1.3 Certifications 3 30d -

PTSW

22 11 00 Facility Water Distribution - 2.1 Pipe and Pipe Fittings

Product Data

30d -

PTSW

22 11 00 Facility Water Distribution - 2.3A Product Data for

Isolation Valves

30d -

PTSW

22 11 00 Facility Water Distribution - 2.3B Product Data for Check

Valves

30d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-5

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

22 11 00 Facility Water Distribution - 2.3C Product Data for Throttle

Valves

30d -

PTSW

22 11 00 Facility Water Distribution - 2.3D Product Data for Vacuum

Breaker Valves

30d -

PTSW

22 11 00 Facility Water Distribution - 2.E Product Data for Other

Minor Components

30d -

PTSW

22 11 00 Facility Water Distribution - 2.4 Product Data for

Electromagnetic Flow Meter

30d -

PTSW

22 11 00 Facility Water Distribution - 2.5 Product Data for Sample

Taps

30d -

PTSW

61 22 11 00 Facility Water Distribution - 2.6 Product Data for Hose Bibs 3 30d -

PTSW

22 11 00 Facility Water Distribution - 2.7 Product Data for Pex Pipe

Insulation

30d -

PTSW

22 11 00 Facility Water Distribution - 2.8 Product Data for Garden

Hose and Hanger

30d -

PTSW

22 11 00 Facility Water Distribution - 2.9 Product Data for Water

Storage Tank and Tank Appurtenances

30d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-6

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

DIVISION 26 - ELECTRICAL

26 00 00 General Provisions for Electrical Work - 1.2.A

Qualifications

15d

ANTP

26 05 19 Low Voltage Electrical Power Cables and Conductors - 1.3

Product Data

30d -

PTSW

26 05 19 Low Voltage Electrical Power Cables and Conductors -

1.4.A. Qualifications

15d

ANTP

26 05 19 Low Voltage Electrical Power Cables and Conductors -

1.4.B. Quality control test reports

3d

ATT

26 05 26 Grounding and Bonding for Electrical Systems - 1.3.A & B

Product Data and Shop Drawings 3 3

15d

ANTP

26 05 26 Grounding and Bonding for Electrical Systems - 1.3.C Test

Reports

3d

ATT

71 26 05 33 Raceways and Boxes for Electrical Systems - 1.3 3 3 15d

ANTP

72 26 05 53 Identification for Electrical Systems - 1.3. Product Data 3 15d

ANTP

73 26 29 13 Enclosed Controllers - 1.4.A. Product Data 3 15d

ANTP

74 26 29 13 Enclosed Controllers - 1.4.B.1. Tabulations 3 15d

ANTP

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-7

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

75 26 29 13 Enclosed Controllers - 1.4.B.2. Wiring Diagrams 3 15d

ANTP

76 26 29 13 Enclosed Controllers - 1.4.C. O&M Data 3 3 PTFI

DIVISION 31 - EARTHWORK

77 31 00 00 Earthwork - 2.1 Borrow Material Product Data 3 30d -

PTSW

78 31 00 00 Earthwork - 2.2 Backfill Product Data 3 30d -

PTSW

79 31 00 00 Earthwork - 2.3A Field Density Testing Results 3 7d - ATT

80 31 00 00 Earthwork - 2.3B Moisture-Density Curves 3 30d - AFI

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 1.2 Excavator Model to be Used

30d -

PTSW

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 1.3A Test Results for Pipe Bedding Sieve and Proctor, Pipe Bedding Compaction, Type A Trench Backfill

Compaction, Type B Trench Backfill Compaction, and Controlled

Low Strength Material

3 1d - ATT

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 1.5 Written Statement of Method of

Maintenance

30d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-8

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 1.8 A. Utility Notices

10d -

PTSW

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 2.1 Type I Bedding Material Product Data

30d -

PTSW

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 2.2 Type II Bedding Material Product Data

30d -

PTSW

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 2.3 Pipe Bedding

30d -

PTSW

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 2.4 Trench Backfill

30d -

PTSW

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 2.6 Plastic Marking Tape

30d -

PTSW

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 2.7A Tracer Wire Product Data

30 d -

PTSW

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 2.7B Tracer Wire Pump House Access

30 d -

PTSW

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 2.7D Gounding Anode

30 d -

PTSW

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 2.7C Splices and/or Connectors

30 d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-9

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

31 23 33 Trench Excavation and Backfill for Pipelines and

Appurtenant Structures - 3.3 H. Written Permission for Off-Site

Disposal from Owner of Property upon which Material is to be

Disposed

7d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-10

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

DIVISION 32 - EXTERIOR

IMPROVEMENTS

32 92 19 Seeding - 2.1 Certificate of Composition and Weed-Free

Certification

30d -

PTSW

96 32 92 19 Seeding - 2.2 Topsoil 3 30d -

PTSW

97 32 92 19 Seeding - 2.3 Fertilizer 3 30d -

PTSW

98 32 92 19 Seeding - 2.4 Fiber Mulch 3 30d -

PTSW

99 32 92 19 Seeding - 3.4 Warranty 3 30d -

PTSW

DIVISION 33 - UTILITIES

100 33 01 10.81 Well Abandonment - 1.1 Proof of Variance 3 30d -

PTSW

101 33 01 10.81 Well Abandonment - 1.1 Well Abandonment Plan 3 30d -

PTSW

102 33 01 10.81 Well Abandonment - 1.2 Well Abandonment Log 3 30d - AFI

103 33 01 10.81 Well Abandonment - 2.1 Bentonite Grout Product Data 3 30d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-11

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

33 05 07.13 Utility Directional Drilling - 1.2 Horizontal Driller

Qualification and Experience

30d -

PTSW

33 05 07.13 Utility Directional Drilling - 1.3 Drilling and Excavation

Plan

30d -

PTSW

106 33 05 07.13 Utility Directional Drilling - 2.1 Carrier Pipe Product Data 3 30d -

PTSW

34 05 07.13 Utility Directional Drilling - 2.1 Drilling Fluid Product

Data

30d -

PTSW

108 33 05 07.13 Utility Directional Drilling - 2.2 Casing Pipe Product Data 3 30d -

PTSW

33 14 16 Site Water Utility Distribution Piping - 2.1 HDPE Pipe

Product Data

30d -

PTSW

33 14 16 Site Water Utility Distribution Piping - 2.2A Butt Fusion

Fittings Product Data

30d -

PTSW

33 14 16 Site Water Utility Distribution Piping - 2.2B Electrofusion

Fitting Product Data

30d -

PTSW

112 33 14 16 Site Water Utility Distribution Piping - 2.3 Markings 3 30d -

PTSW

33 14 16 Site Water Utility Distribution Piping - 2.4B Closed Cell

Foam Pipe Insulation Product Data

30d -

PTSW

34 14 16 Site Water Utility Distribution Piping - 2.4C Rigid Board

Insulation Product Data

30d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-12

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

34 14 16 Site Water Utility Distribution Piping - 3.5A Qualification of

Master Plumber

30d -

PTSW

34 14 16 Site Water Utility Distribution Piping - 3.11C Bacteriological

Tests

30d -

PTSW

33 21 00 Water Supply Wells - 1.2 All Necessary Permits and

Certificates 3 3

7d -

PTSW

118 33 21 00 Water Supply Wells - 1.4 Well Report 3 60d - ATT

119 33 21 00 Water Supply Wells - 1.7 Documentation of Competence 3 30d -

PTSW

33 21 00 Water Supply Wells - 1.8 Qualifications of Geologist and

Geophysicist

30d -

PTSW

121 33 21 00 Water Supply Wells - 1.12 A. Drawings, Diagrams, Etc. 3 3 30d -

PTSW

33 21 00 Water Supply Wells - 1.12 B. Name of Laboratory Used for

Water Sample Analysis

30d -

PTSW

123 33 21 00 Water Supply Wells - 1.12 D. Manufacturer's Certificates 3 30d -

PTSW

33 21 00 Water Supply Wells - 1.12 E Qualification Statements of

Subcontractors

30d -

PTSW

33 21 00 Water Supply Wells - 1.12 G Drilling Equipment Product

Data

30d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-13

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

126 33 21 00 Water Supply Wells - 1.12 H Closeout Submittals 3 30d - AFI

127 33 21 00 Water Supply Wells - 2.1 Drilling Fluids Product Data 3 30d -

PTSW

128 33 21 00 Water Supply Wells - 2.2 Well Casing Product Data 3 30d -

PTSW

129 33 21 00 Water Supply Wells - 2.3 Conductor Pipe Product Data 3 30d -

PTSW

130 33 21 00 Water Supply Wells - 2.4 Well Screen Product Data 3 30d -

PTSW

131 33 21 00 Water Supply Wells - 2.5 Sealing Grout Product Data 3 30d -

PTSW

132 33 21 00 Water Supply Wells - 2.6 Well Pump Product Data 3 30d -

PTSW

133 33 21 00 Water Supply Wells - 2.7 Pitless Adaptor Unit Product Data 3 30d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-14

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

134 33 21 00 Water Supply Wells - 2.8 Well Cap Product Data 3 30d -

PTSW

135 33 21 00 Water Supply Wells - 2.9 Drop Pipe Product Data 3 30d -

PTSW

136 33 21 00 Water Supply Wells - 2.10 Check Valves Product Data 3 30d -

PTSW

137 33 21 00 Water Supply Wells - 2.11 Torque Arrestor Product Data 3 30d -

PTSW

138 33 21 00 Water Supply Wells - 2.12 Coupler Product Data 3 30d -

PTSW

139 33 21 00 Water Supply Wells - 3.2 Drilling Fluid Properties Log 3 30d - AFI

140 33 21 00 Water Supply Wells - 3.3 Borehole Log 3 30d - AFI

141 33 21 00 Water Supply Wells - 3.4 Results of Water Sampling 3 60d - ATT

142 33 21 00 Water Supply Wells - 3.5 Well Log 3 30d - AFI

143 33 21 00 Water Supply Wells - 3.6 Rate of Penetration Log 3 30d - AFI

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-15

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

144 33 21 00 Water Supply Wells - 3.7 Geophysical Log 3 30d - AFI

145 33 21 00 Water Supply Wells - 3.8 Stratigraphic Log 3 30d - AFI

146 33 21 00 Water Supply Wells - 3.14 Video Inspection 3 30d - AFI

147 33 21 00 Water Supply Wells - 3.15 Well Development Records 3 30d - AFI

33 21 00 Water Supply Wells - 3.16 Performance Testing Records and

Reports 3 30d - AFI

149 33 31 13 Effluent Water Pipe - 2.2A PVC Pipe Product Data 3 30d -

PTSW

33 31 13 Effluent Water Pipe - 2.4A Precast Concrete Manhole

Sections

30d -

PTSW

151 33 31 13 Effluent Water Pipe - 2.4B Manhole Rings and Covers 3 30d -

PTSW

152 33 31 13 Effluent Water Pipe - 2.4C Manhole Steps 3 30d -

PTSW

153 33 31 13 Effluent Water Pipe - 2.4D Manhole Exterior Coating 3 30d -

PTSW

154 33 31 13 Effluent Water Pipe - 2.4E Manhole Joints 3 30d -

PTSW

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-16

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

155 33 31 13 Effluent Water Pipe - 2.6A Isolation Valve 3 30d -

PTSW

156 33 31 13 Effluent Water Pipe - 2.6B Check Valve 3 30d -

PTSW

157 33 31 13 Effluent Water Pipe - 2.6C Throttling Valve 3 30d -

PTSW

158 33 31 13 Effluent Water Pipe - 2.6D Vacuum Breaker Valve 3 30d -

PTSW

159 33 31 13 Effluent Water Pipe - 2.6E Water Leve Transducer 3 30d -

PTSW

160 33 31 13 Effluent Water Pipe - 2.6F Other Minor Components 3 30d -

PTSW

33 31 13 Effluent Water Pipe - 2.7A Effluent Line Equipment

Eletromagnetic Flow Meter

30d -

PTSW

33 31 13 Effluent Water Pipe - 2.7B Electromagnetic Flow Meter

Alarm

30d -

PTSW

163 33 31 13 Effluent Water Pipe - 3.5A Leakage Testing 3 30d - AFI

164 33 31 13 Effluent Water Pipe - 3.5B Television Inspection 3 30d - AFI

165 33 31 13 Effluent Water Pipe - 3.5C Leakage Test 3 30d - AFI

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-17

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

166 33 31 13 Effluent Water Pipe - 3.5 D Deflection Tests 3 30d - AFI

33 31 13 Effluent Water Pipe - 3.5E Materials and Equipment for

Testing 3 30d - AFI

33 38 10 Wastewater Disposal - 1.2 Permits, Certificates, Law and

Ordinances 3 3

30d -

PTSW

169 33 38 10 Wastewater Disposal - 1.6 Licensed Septic Hauler 3 30d - PTE

33 38 10 Wastewater Disposal - 1.9A Product Data for Equipment

Used to Perform the Work

30d -

PTSW

171 33 38 10 Wastewater Disposal - 1.9B Wastewater Laboratory Results 3 30d - PTE

172 33 38 10 Wastewater Disposal - 1.9C Disposal Paperwork 3 30d - AE

33 38 10 Wastewater Disposal - 1.9D Names of Wastewater

Treatment Facilities 3 30d - PTE

33 38 10 Wastewater Disposal - 1.9E Letter from Wastewater

Treatment Plant 3 30d - PTE

175 33 38 10 Wastewater Disposal - 1.9F Project Record Documents 3 30d - AE

DIVISION 46 - WATER AND WASTEWATER

EQUIPMENT

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-18

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

176 46 07 01 Water Treatment Equipment - 1.4A Qualifications 3 30d-

PTSW

46 07 01 Water Treatment Equipment - 1.4B Modification

Requirements 3 3 30d - PTB

46 07 01 Water Treatment Equipment - 1.6A Product Data for

Sediment Filter, RO Supply Pump, Carbon Filter (if applicable), Zeolite Filter (if applicable), RO System and Components, Calcite

System, Hypochlorite Disinfection System, Carbon Filter, Pressure

Guages, Effluent Line Pump with control floats, Effluent Water

Tank, Water Pressure Transducer and Alarm Float, Alarm Systems, and All Appurtenances.

30d -

PTSW

179 46 07 01 Water Treatment Equipment - 1.6B Warranty Information 3 3 30d -

PTSW

46 07 01 Water Treatment Equipment - 1.6C Dimensions and

Installation Requirements of Water Treatment Equipment

30d -

PTSW

46 07 01 Water Treatment Equipment - 1.6D Manufacturer

Qualifications

30d -

PTSW

182 46 07 01 Water Treatment Equipment - 1.6E Skid Design 3 30d -

PTSW

183 46 07 01 Water Treatment Equipment - 1.6F Water Sample Results 3 30d-AFI

46 07 01 Water Treatment Equipment - 1.6G Facrory Test Results and Field Test Results 3 30d-AFI

46 07 01 Water Treatment Equipment - 1.6H User's Manuals-1 electronic copy and 3 hard copies prior to payment 3 15d PTE

46 07 01 Water Treatment Equipment - 1.6I Shop Drawings, Manufacturer's Literature, Certificate of Compliance, Equipment

Data, O&M Information, Guarantees, Electrical Schematics, Flow

Diagrams, and Sequence of Operation

3 15d ANP

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-19

FA4626-20-R-0006

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR

L

IN

E N

U M

B E

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL

C E

R T

IF

IC

A T

IO

N

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E

C O

M M

E N

D A

T

IO

N S

M A

N U

F A

C T

U R

E

R R

A N

T Y

C A

T A

L O

G D

A T

A

O P

E R

A T

T R

U C

T

IO

N S

N O

T

IF

IC

A

T

IO

N

O T

H E

R

R E

Q U

IR

E

D S

U B

M

IS

S

N T

R A

C T

O R

D A

T E

R E

C E

IV

E

D

N T

R A

C T

IN

G

D A

T E

T O

C

G

IN

E E

R

IN

G

R E

T U

R N

S U

S P

E N

T E

S U

B M

IT

T

A L

N U

M B

E R

S

C O

N T

R A

C T

S U

B M

IT

T

A L

A P

P R

O V

A L

REMARKS

APPROVED

DIS-

APPRO

VED

Number of Copies Required

NZAS 16-6006

Repair MAF E-01 Domestic Water

Well

DATE CONTRACTOR

NOTIFIED

46 07 01 Water Treatment Equipment - 1.8A Contractor Guarantee from Each Manufacturer 3 30d AFI

46 07 01 Water Treatment Equipment - 1.8B Skid Assembly

Manufacturer Guarantee 3 30d AFI

46 07 01 Water Treatment Equipment - 1.8CSkid System One-Year

Warranty 3 30d AFI

190 46 07 01 Water Treatment Equipment - 3.5A Instruction and Training 3 7d - AE

191 46 07 01 Water Treatment Equipment - 3.5B O&M 3 2w-PTE

192 46 07 01 Water Treatment Equipment - 3.56 Spare Parts 3 PTFI

Schedule of Abbreviations:

AFI = After Final Inspection BD= Before Delivery

ANP= After Notice to Proceed PTB= Prior To Bid

ATT= After Test Taken PTE=Prior to Event

AE= After Event PTFI= Prior to Final Inspection

BBCW= Before Beginning Concrete Work PTSW= Prior to Start of Work

AF Form 66

Submittal Schedule MAF E01 Rev 2-12/11/2019

01330a-20

File details come from the government source that posted it. Updated .