NEW - JBMDL B678 Laboratory Expansion_M20 - Sheet - M-103 - MECHANICAL FLOOR PLAN - AREA B.pdf
PDF 356 KB Posted
- Attached to
- Building 678 Laboratory Expansion Federal contract opportunity
- Solicitation number
- FA448422R0010
About this file
This solicitation is for a construction contract to expand an existing laboratory building at Joint Base McGuire Dix Lakehurst in New Jersey. The project scope includes demolition, new construction, and renovation work. The period of performance is one year. This opportunity is set aside for a HUBZone small business with a contract value estimated between $5 million to $10 million. Offerors should submit pricing on the bid schedule by 2 May 2022 and include past performance evaluations. A site visit will be conducted on 12 April 2022. All questions are due by 19 April 2022. The NAICS code is 236220 and the size standard is $39.5 million. The soliciting agency is the Department of the Air Force Air Mobility Command.
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
M
T
T
T
T
M
HWP-2
HWP-1
UH-1
M-401
A1
EG-1
50 CFM
EG-1
190 CFM
EG-1
210 CFM
x1
E
A
8x8 EA
VAV-5
8x8 SA
SD-1, 8ø 50 CFMSD-1, 8ø
140 CFM
SD-1, 8ø
190 CFM
(TYP. 2)
8x8 SA
DSS-1
RECYCLE
COMM
LACTATION ROOM
OAD-1
80 CFM
SD-1, 8ø
190 CFM
x1
S
A
DCU-1
ESO
SD-1, 8ø
140 CFM
ELEC
SD-4
50 CFM
MECH
CONFERENCE
STOR
MEN
WOMEN
EG-1, 8ø
100 CFM
MATCHLINE
x1
O
S A
H-1
16x16 OSA DOWN
FROM MUA-1.
SEE SHEET M-104
FOR CONTINUATION.
12x12 EA DOWN
FROM MUA-1. SEE
SHEET M-104 FOR
CONTINUATION.
30x22 SA DOWN FROM
AHU-1. SEE SHEET
M-104 FOR
CONTINUATION.
38x24 RA DOWN
FROM AHU-1. SEE
SHEET M-104 FOR
CONTINUATION.
SD
SD
8x8 EA 8x8 EA
MATCHLINE
RD-1
175 CFM
x8
R A x8
R A
RD-1
175 CFM
8x10
24x24 RA
HWP-2
HWP-1
UH-1
EG-1
50 CFM
EG-1
190 CFM
EG-1
210 CFM
BELOW
10x12 EA
8x8 EA
VAV-5
8x8 SA
SD-1, 8ø
50 CFM
SD-1, 8ø
140 CFM
SD-1, 8ø
190 CFM
(TYP. 2) 8x8 SA x1
S
A
DSS-1
RECYCLE
COMM
LACTATION ROOM
CORR
OAD-1
80 CFM
SD-1, 8ø
190 CFM
x1
S
A
DCU-1
ESO
FPVAV-4
FPVAV-5
10x6 SA
10x10 SA x6
S A
10x6 SA 1 x1
S
A
8x6 OSA
SD-1, 10ø
230 CFM
SD-2, 10ø
230 CFM
(TYP. 2)
SD-2, 10ø
230 CFM
(TYP. 1)
SD-1
230 CFM
OAD-1, 8ø
40 CFM
SD-1, 8ø
90 CFM
RD-1
125 CFM
VAV-6
OAD-1, 8ø
40 CFM
SD-1, 8ø
90 CFM
RD-1
125 CFM
OAD-1, 8ø
145 CFM
OAD-1, 8ø
145 CFM
10x10 SA
10x10 SA x6
R A
10x8 OSA x1
S
A
ABOVE
10x10 OSA
16x16 OSA DOWN
FROM MUA-1.
SEE SHEET M-104
FOR CONTINUATION.
SD-1, 8ø
140 CFM
18x14 SA
M-401
A1
E1
M-301
E4
M-301
EG-1, 8ø
100 CFM
ELEC
RD-1
RD-1
12x12 OSA DOWN
FROM MUA-1. SEE
SHEET M-104 FOR
CONTINUATION.
30x22 SA DOWN FROM
AHU-1. SEE SHEET
M-104 FOR
CONTINUATION.
38x24 RA DOWN
FROM AHU-1. SEE
SHEET M-104 FOR
CONTINUATION.
MATCHLINE
H-1
SD
SD
x1
O
S A
8x8 EA8x8 EA
RD-1
510 CFM
RD-1
510 CFMSD-4
50 CFM
MECH
MATCHLINE
SD-1
230 CFM SD-1
230 CFM
RD-1
510 CFM
20x12 RA
16x14 RA
RD-1
510 CFM
SD-1, 10ø
230 CFM
x2
R
A
20x20 RA
SHEET ID
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
BIM 360://JBMDL B678 Lab Expansion/0690-00-JBMDL B678 Laboratory Expansion_M20.rvt
4/20/2022 4:58:00 PM
M-103
M E
C H
A N
IC
A
L F
L O
O R
P L A
N
A R
E A
B
N A
V A
L A
IR
W
A R
F A
R E
C E
N T
E R
A
IR
C
R A
F T
D
IV
IS
IO
N
N A
W C
A D
D
H
E R
N A
N D
E Z
A W
E L L S
D C
A V
IN
A B
U S
B Y
J U
L Y
FINAL DESIGN SUBMITTAL - FOR CONSTRUCTION
L A
K E
H U
R S
T N
J
J O
IN
T
B A
S E
M C
G U
IR
E
-D
IX
-L A
K E
H U
R S
T B
L
A B
O R
A T
O R
Y E
X P
A N
S
IO
N
1/8" = 1'-0"B5
MECHANICAL FLOOR PLAN - AREA B BASE BID
SHEET KEYNOTES
GENERAL SHEET NOTES
1. SEE SHEETS M-001 AND M-002 FOR LEGENDS,
ABBREVAITIONS, AND GENERAL NOTES.
2. CONTRACTORS SHALL INSTALL ALL EQUIPMENT,
DUCTWORK, AND PIPING IN A NEAT ORDERLY
FASHION.
3. SEE MP102 FOR HYDRONIC PIPING DESIGN.
1. PROVIDE NEW REHEAT VAV TERMINAL BOX AS
SHOWN.
2. PROVIDE NEW FAN POWERED SERIES VAV REHEAT
TERMINAL UNIT AS SHOWN.
3. PROVIDE NEW FAN POWERED VAV BOX AREA B- BID
OPTION 2. SEE SHEET M-602 FOR BID OPTION
SCHEDULE.
4. PROVIDE NEW REHEAT VAV TERMINAL BOX AREA B-
BID OPTION 2. SEE SHEET M-602 FOR BID OPTION
SCHEDULE.
0 2' 4' 8' 16'
PLAN NORTH
A
KEY PLAN
B
EXISTING
1/8" = 1'-0"D1
MECHANICAL FLOOR PLAN - AREA B BID OPTION 02
0 2' 4' 8' 16'
PLAN NORTH
A
M E
N D
M E
N T
I N
R E
S P
O N
S E
T O
B
ID
D E
R I
N Q
U
IR
IE
S
A P
R
| Sheets |
| M-103 - MECHANICAL FLOOR PLAN - AREA B |
File details come from the government source that posted it. Updated .