Addendum 01 - Attachment 4 - Specification 31 31 16.19 - Termite Control Barriers.pdf

PDF 9 KB Posted

Attached to
B2190 Construct Munitions Load/Unload Facilities Building
Solicitation number
FA441823R0011
Issued by

View the file

Other files

File Type Posted
Solicitation Amendment FA441823R00110001 SF 30.pdf PDF
Solicitation Amendment FA441823R00110001 SF 30.pdf PDF
Addendum 01 - Attachment 3 - Specification 08 14 00 - Wood Doors.pdf PDF
Addendum 01 - Attachment 1 - Specification 03 45 00 - Precast Architectural Concrete.pdf PDF
FA441823R0011 - Addendum 01 - Construct HAZMAT Load-Unload Facility B2190.pdf PDF
Addendum 01 - Attachment 2 - Specification 07 42 13 - Metal Wal Panels.pdf PDF
Questions and Answers - B2190.pdf PDF
B2190 - 20230217 - 16.jpg JPG image
B2190 - 20230217 - 18.jpg JPG image
B2190 - 20230217 - 10.jpg JPG image
B2190 - 20230217 - 3.jpg JPG image
B2190 - 20230217 - 7.jpg JPG image
B2190 - 20230217 - 14.jpg JPG image
B2190 - 20230217 - 9.jpg JPG image
B2190 - 20230217 - 5.jpg JPG image
B2190 - 20230217 - 12.jpg JPG image
B2190 - 20230217 - 15.jpg JPG image
B2190 - 20230217 - 17.jpg JPG image
B2190 - 20230217 - 11.jpg JPG image
B2190 - 20230217 - 2.jpg JPG image
B2190 - 20230217 - 8.jpg JPG image
B2190 - 20230217 - 1.jpg JPG image
B2190 - 20230217 - 6.jpg JPG image
B2190 - 20230217 - 13.jpg JPG image
B2190 - 20230217 - 4.jpg JPG image
FA441823R0011 - B2190 - Site Visit Sign In Sheet.pdf PDF
B2190 Site Visit List 13FEB23.pdf PDF
Davis-Bacon Act WD SC20230023 Mod 0 06JAN23.pdf PDF
JB Charleston - Question and Answer Form - B2190.xlsx XLSX spreadsheet
Solicitation - FA441823R0011.pdf PDF
Site Visit Burger King Map.png PNG image
15a - Submittal Register B2190.pdf PDF
17b - Specifications B2190.pdf PDF
17a - Drawings B2190.pdf PDF
15 - Submittal Register B2190.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Construct HAZMAT Load-Unload Facility, B.2190 Addendum No. 2 JBC No. DKFX 1051228 March 1, 2023

SECTION 31 31 16.19

TERMITE CONTROL BARRIERS

08/22

PART 1 GENERAL

1.1 SUBMITTALS

Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-03 Product Data

Written Warranty ; G

SD-08 Manufacturer's Instructions ; G

SD-11 Closeout Submittals

Written Warranty ; G

1.2 DELIVERY, STORAGE, AND HANDLING

1.3 SITE CONDITIONS

1.3.1 Environmental Requirements

In addition to the manufacturer's installation instructions and before placing material, ensure project site is free from standing water.

1.4 WARRANTY

Furnish a 5-year written warranty against infestations or reinfestation by subterranean termites of the buildings or building additions constructed under this contract. Written warranty must be jointly signed by an officer of the Contractor and the supplier. Perform annual inspections of the building or building addition. If live subterranean termite infestation or subterranean termite damage is discovered during the warranty period, and building conditions have not been altered in the interim, take the following actions:

a. Correct defective installation and perform other treatment as may be necessary to eliminate subterranean termite infestation.

b. Repair damage caused by termite infestation.

c. Reinspect the building approximately 180 calendar days after the repair.

SECTION 31 31 16.19 Page 1

Construct HAZMAT Load-Unload Facility, B.2190 Addendum No. 2 JBC No. DKFX 1051228 March 1, 2023

PART 2 PRODUCTS

2.1 SYSTEM DESCRIPTION

2.2 MATERIALS

PART 3 EXECUTION

3.1 PREPARATION

Provide finished or temporary site grading to remove standing water from the project site (i.e., excavated areas or adjacent areas). Grading must provide positive drainage towards temporary, new or existing drainage features. Grading must not result in low spots that hold water or direct water towards new or existing facilities.

3.2 INSTALLATION

-- End of Section --