Bid Schedule - Summary

CONTRACT YEARDESCRIPTIONAMOUNT
First Year PoPBldg. Envelope Repair, CLIN 0001 - Total - PoP EST 1 Aug 18 - 31 Jul 19 (365 days from date of award)$0.00
Second Year PoPBldg. Envelope Repair, CLIN 0001 - Total - PoP EST 1 Aug 19 - 31 Jul 20$0.00
Third Year PoPBldg. Envelope Repair, CLIN 0001 – Total - PoP EST 1Aug 20 - 31 Jul 21$0.00
Total Proposed Cost (Include all three PoPs)$0.00
The Quantities on the Following Pages are not Guaranteed Quantities.
PoP = Period of Performance
1 August is the Estimated Award Date. The first PoP will be 365 from date of award.
The other two PoP's will also adjust to the award date and are 365 days each.
Total of 3 years.
CCAFS/PAFB - REPAIR BUILDING ENVELOPE&"Times New Roman,Regular"&14&U&A
FOR OFFICIAL USE ONLY12 MAR 2018

ATCH 2 (&P OF &N)

Bid Schedule - 1Aug18-31Jul19

ITEMSCOPE OF WORK DESCRIPTION
Unit costs are all inclusive to include labor, material, equipment, transportation, bond, profit, overhead, all and any direct and/or indirect costs etc., that is, any cost that can be associated with the scope of the line item is to be include in the unit cost.SPEC./DTL. REFERENCEUNITEST QUANTUNIT
COSTTOTAL
Division 02 - Site Construction

(Unless otherwise noted, items in this division shall be "removed and disposed" of accordance with Federal, State, County and City ordinances.)

Section 02 41 00 - Selective Demolition: Provide labor, equipment, material & all accessories needed to remove item or perform Demolition action listed below & to dispose of debris produced
A0001Built-up asphalt or coal tar pitch roofing with aggregate surfacing down to the roof deck surface. To include, but not limited to, membrane, penetration and wall flashings, cants, crickets, insulation up to 6" thick, and all fasteners. Minimum Quantity per Building per delivery order: 500 SF.SPEC: 02 41 00SF20,000$0.00
A0002Built-up smooth surfaced asphalt roofing, modified bitumen roofing with granular surface cap sheet, fully adhered single ply roofing (including any of the following membrane types: PVC, EPDM, PIB and other membrane roofing types), and mechanically fastened single ply roofing (including any of the following membrane types: PVC, EPDM, PIB and other membrane roofing types) down to the roof deck surface. To include, but not limited to, membrane, penetration and wall flashings, cants, crickets, insulation up to an average of 6 " thick, and all fasteners. Minimum Quantity per Building per delivery order: 500 SF.SPEC: 02 41 00SF10,000$0.00
A0003Remove roof membrane NOT TO INCLUDE insulation, crickets and insulation fasteners for (1) built-up asphalt or coal tar pitch roofing with aggregate surfacing, (2) built-up smooth surfaced asphalt roofing, (3) fully adhered or mechanically fastened single ply roofing (including any of the following membrane types: PVC, EPDM, PIB and single ply other membrane roofing types) . Include membrane, penetration & wall flashings & membrane fasteners. Minimum Quantity per Building per delivery order: 500 SF.SPEC: 02 41 00SF5,000$0.00
A0004Aggregate ballast. Include spudding-back and vacuuming loose aggregate from entire roof surface. Minimum Quantity per Building per delivery order: 250 SF.SPEC: 02 41 00SF16,000$0.00
A0005Insulation or additional insulation up to an average of 6" thick, from entire roof surface area. Minimum Quantity per Building per delivery order: 500 SF.SPEC: 02 41 00SF5,000$0.00
A0006Metal roof or wall panels w/exposed or concealed fasteners and abandoned equipment capped curb and/or opening, including edge and rake flashings to the structural sub-framing or decking. Include all clips, anchors, fasteners and accessories. Minimum Quantity per Building per delivery order: 100 SF.SPEC: 02 41 00SF10,000$0.00
A0007Sheet Metal Flashing items with cleat and associated fasteners, cap flashing, expansion joint covers, parapet coping caps, gravel stop, drip edge and other similar items. Minimum Quantity per Building per delivery order: 25 LF.SPEC: 02 41 00LF5,000$0.00
A0008Termination sheet metal items including counter flashings, skirt flashings, reglets and termination bars at walls or curbs. Minimum Quantity per Building per delivery order: 25 LF.SPEC: 02 41 00LF5,000$0.00
A0009Metal pitch pans including grout and sealant. (up to 6"x6"x4" tall)SPEC: 02 41 00EA25$0.00
A0010Metal gutter and / or downspout assembly including anchors, hangars, straps, and fasteners. Minimum Quantity per Building per delivery order: 25 LF.SPEC: 02 41 00LF1,000$0.00
A0011Metal scupper assembly or metal conductor box including anchors, associated flashing, hangars, straps, and fasteners.SPEC: 02 41 00EA50$0.00
A0012Wood blocking including anchors, hangars, straps, and fasteners. Minimum Quantity per Building per delivery order: 10 BF.SPEC: 02 41 00BF5,000$0.00
A0013Plywood including anchors, straps, and fasteners. Minimum Quantity per Building per delivery order: 16 SF.SPEC: 02 41 00SF500$0.00
A0014Remove, protect, store and re-install corrugated fiberglass or fluted metal wall panels with exposed fasteners to perform associated roof work. Minimum Quantity per Building per delivery order: 50 SF.SPEC: 02 41 00SF500$0.00
A0015Metal hat channels, purlins, girts, angles and other supports associated with roof and wall panels (metal, fiberglass, or plastic). Include all associated clips, anchors and fasteners. Minimum Quantity per Building per delivery order: 100 LF.SPEC: 02 41 00LB500$0.00
A0016Abandoned and/or deteriorated piping, fittings, conduit, wiring, supports, straps, and items usually associated with rooftop mechanical equipment. Minimum Quantity per Building per delivery order: 10 LF.SPEC: 02 41 00LF300$0.00
A0017Abandon or deteriorated equipment/debris and/or structures from the roof area. Minimum 1/2 Ton.SPEC: 02 41 00Ton2$0.00
A0018Miscellaneous metals and structural components including joist, girders, angles, plates, doors, frames, gratings, ladders, railings, etc. Minimum 100 lbs."SPEC: 02 41 00LB100$0.00
A0019Saw cut, remove and dispose of masonry or CMU. Minimum 10 CFSPEC: 02 41 00CF10$0.00
A0020Saw cut, remove and dispose of concrete. Minimum 10 CFSPEC: 02 41 00CF10$0.00
A0021Remove/demo gypsum board, plaster w/lathe, or soffit (wood, aluminum, or vinyl). Min. = 20 S.F.SPEC: 09 29 00; 1.5SF800$0.00
Section 02 82 13 - Asbestos Abatement
A0022Remove CLASS I & / or CLASS II asbestos containing roof materials (ACRM) roof membrane including all required air sampling. Min. Quantity per Bldg. per D.O.: 10 S.F.SPEC: 02 82 13SF400$0.00
A0023Remove Corrugated asbestos wall panels ("Transite" or equivalent) including all required air sampling. Min. Quantity per Bldg. per D.O.: 20 S.F.SPEC: 02 82 13SF400$0.00
A0024Remove Cementitious asbestos fiber roof deck/form board w associate gypsum deck ("Transite" or equivalent) including all required air sampling. Min. Quantity per Bldg. per D.O.: 20 S.F.SPEC: 02 82 13SF5,000$0.00
Section 02 83 13 - Lead in Construction
A0025Haz paint removal (i.e. Lead/RCRA metals below RCRA limits) abatement, including class 1a, 1w, 1p, 1c, 2a, 2w, 2p, or 2c containment. Min. Quantity per Bldg. per D.O.: 20 S.F.SPEC: 09 90 01; 3.6, 09 97 00; 3.5SF250$0.00
A0026Haz paint removal (i.e. Lead/RCRA metals) abatement, including class 3a, 3w, 3p, 3c, 4a, 4w, 4p, or 4c, containment. Min. Quantity per Bldg. per D.O.: 20 S.F.SPEC: 10 90 01; 3.6, 09 97 00; 3.5SF250$0.00
A0027Regulated metals testing (i.e. 8 RCRA metals, AA/ICP TOTAL CONSTITUENT ANALYSIS)SPEC: 09 90 01; 3.3, 09 90 02; 3.3EA4$0.00
Division 03 - Concrete

(Unless otherwise noted, items this division shall be "furnished and installed".)

Section 03 51 00 - Roof Deck Replacement, Cast-in-Place Gypsum Concrete
A0028Remove, dispose of and replace areas of deteriorated or damaged woven wire reinforcement. Install woven wire reinforcement in accordance with manufacturer's written instructions. Average area of repair (12) SF.SPEC: 02 41 02SF100$0.00
A0029Furnish and install new Cut-to-Fit USG-"SECUROCK" form board from ½" x 4'-0" x 8'-0" Roof Board into existing steel roof deck framing. Minimum (24) SFSPEC: 03 51 00SF100$0.00
A0030Furnish and install by cold adhesive, mechanical attachment, or Type IV hot mopped asphalt 1/2' USG-"SECUROCK" form board as required by manufacturer. Minimum (24) SFSPEC: 03 51 00SF100$0.00
A0031Remove, dispose steel bulb tee supports. Minimum (50) LF.SPEC: 03 51 00LF50$0.00
Section 03 51 00, 03 52 00 - Roof Decking, Cast-in-Place Low Density/Gypsum Concrete

(Unless otherwise noted, items in this division include "removal and disposal" in accordance with Federal, State, County and City ordinances. "Furnish and install" new components.)

A0032Remove and repair small damaged areas of lightweight or gypsum concrete deck with new lightweight concrete. Minimum size of each repair – 2" deep over 10 SF.SPEC: 03 51 00,
03 52 00CF100$0.00
A0033Remove damaged lightweight or gypsum concrete down to the form board or deck and repair with new lightweight insulating concrete. Minimum size of each repair – 3" deep over 10 SF.SPEC: 03 51 00,
03 52 00CF100$0.00
Division 04 - Masonry

(Unless otherwise noted, new items in this division shall be "furnished and installed" and old components shall be "removed and disposed" of accordance with Federal, State, County and City ordinances.)

Section 04 01 20 - Maintenance of Unit Masonry
A0034Water blast clean existing masonry or other wall surface(s) in accordance with paint manufacturer's recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 04 01 20SF500$0.00
A0035Concrete masonry units to include grouting, tuck pointing, formwork, and supports . Perform work in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 30 SFSPEC: 04 01 20SF50$0.00
Division 05 - Metals

(Unless otherwise noted, items in this division shall be "fabricated/furnished and installed".)

Section 05 30 00 - Steel Decks
A0036Primed structural steel roof decking; including 1" to 2" deep flutes, 18 to 22 gauge, G-90 to include the installation of associated items, including panel edge closures and miscellaneous perimeter and wall items. Minimum Quantity per Building per delivery order: 20 SF.SPEC: 05 30 00SF10,000$0.00
Section 05 40 00 - Cold-Formed Metal Framing
A0037Cold-formed metal framing members or metal soffit framing, to include saddles, cant strips, curbs for scuttles and ventilators, and nailers attached at the tops of concrete or masonry curbs, expansion joints and roof edges. Framing members are 4" to 8" wide by 18 gauge or thinner. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 05 40 00LF100$0.00
A0038Retrofit sub-purlin and/or formed shaped framing system mechanically fastened to existing framing and/or substrate in accordance with manufacturer's recommendations. Include all anchors, fasteners, clips, connectors and accessories. Minimum 16 gauge thickness. Minimum Quantity per Building per delivery order: 100 LFSPEC: 05 40 00 paragraph 2.3LF100$0.00
Section 05 50 00 - Metal Fabrication
A0039Shop primed steel materials including but not limited to: weld plates, angles for casting into concrete, anchor bolts, steel pipe sleeves, and wedge-type inserts to be cast into concrete or built into unit masonry, framing, supports and fabricated items for applications that are not specified in other specification sections. Minimum Quantity per Building per delivery order: 25 lbs.SPEC: 05 50 00LB200$0.00
A0040Furnish and install new photoengraved 0.032 inch thick aluminum roof warranty sign.SPEC: 05 50 00EA25$0.00
Section 05 51 33 - Metal Ladders
A0041Aluminum lockable ladder security door installed at base of ladder - 14 gauge aluminum sheet, 8 feet tall. Door must be able to withstand a 200-pound force applied at any point from any direction.SPEC: 05 51 33 DWG. 8.09 and 8.10EA5$0.00
A0042Install ladder safety rail system for new or existing aluminum or Fiberglass Reinforced Plastic (FRP) Ladder. Minimum 30 LF.SPEC: 05 51 33 DWG. 8.09 and 8.10LF30$0.00
A0043Fabricate and install aluminum roof access ladder system, which includes but not limited to, side rails, rungs, mounting brackets, without cage and/or related safety rail system. Minimum 20 LF.SPEC: 05 51 33LF30$0.00
A0044Clean, prime, paint and finish areas of deteriorated existing roof access ladder system, which includes but not limited to, side rails, rungs, cage and/or mounting brackets. Perform work in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 05 51 33LF30$0.00
Section 05 52 13 - Pipe and Tube Railings
A0045Fabricate and install a side or base mount aluminum pipe and/or tube guardrail system. Minimum 12 LF.SPEC: 05 52 13LF24$0.00
Division 06 - Wood and Plastics

(Unless otherwise noted, items in this division shall be "fabricated/furnished and installed".)

Section 06 10 00 - Rough Carpentry
A0046Re-secure existing roof nailers to roof deck and/or substrate to meet current uplift requirements which includes an average size of 6 inches wide by 4 inches thick (double 2x 6 typical). Minimum Quantity per Building per delivery order: 25 LF.SPEC: 06 10 00LF5,000$0.00
A0047Preservative-treated wood roof nailers, which includes wood saddles or crickets, cant strips, curbs for scuttles and ventilators, and wood nailers bolted to tops of concrete or masonry curbs and at expansion joints.SPEC: 06 10 00BF5,000$0.00
A0048Preservative-treated wood roof nailers, to meet current uplift requirements which includes perimeter of roof, around openings through roof, and where roofs abut walls, curbs, and other vertical surfaces.SPEC: 06 10 00BF5,000$0.00
A0049Furnish and install roof framing lumber, which includes studs, plates, caps, collar beams, bucks, sleepers, nailing strips and sills.SPEC: 06 10 00BF100$0.00
A0050Up to 3/4" plywood roof or wall sheathing. Minimum Quantity per Building per delivery order: 32 SF.SPEC: 06 10 00SF1,000$0.00
A0051Preservative-treated fascia lumber, which includes 1X or 2X nominal thicknesses. Minimum Quantity per Building per delivery order: 10 BF.SPEC: 06 10 00BF2,500$0.00
A0052Cementious hard board wall siding, up to 1/4" thickness. Min. = 10 S.F.SF1,000$0.00
A0053Cementious hard board vented soffit, up to 5/16" thick. Min. = 10 S.F.SF1,000$0.00
Section 06 71 33 - Fiberglass Reinforced Plastic (FRP) Ladders
A0054Fabricate and install FRP ladder system, which includes but limited to, side rails, rungs, mounting brackets, without cage and related safety rail system. Minimum 15 LF.SPEC: 06 71 33LF20$0.00
Section 06 82 14 - Fiberglass Reinforced Plastic (FRP) Pipe and Tube Railings
A0055FRP pipe and/or tube side or base mounted guardrail system. Minimum Quantity per Building per delivery order: 12 LF.SPEC: 06 82 14LF24$0.00
Division 07 - Thermal and Moisture Protection

(Unless otherwise noted, items in this division include "removal and disposal" in accordance with Federal, State, County and City ordinances. "Furnish/fabricate and install" new components.)

Section 07 14 16 - Cold Fluid-Applied Roofing System
A0056Furnish and install water based, acrylic elastomeric roof coating, SOLARGARD ELASTOMERIC 6083 waterproofing system, to metal roofing system to include 16 to 20 wet mils of SOLARGARD 6083 and two, 6 to 8 mil applications of SOLARGARD ACRYTHANE. All stages of preparation and application will be in accordance with manufacturer’s recommendations, and all accessory materials (to include fabric reinforcement) recommended by the manufacturer will be utilize and/or apply. Minimum Quantity per Building per delivery order: 100 SF.SPEC: 07 14 16SF2,000$0.00
A0057Furnish and install two coat, urethane, elastomeric roof coating, GEOGARD waterproofing system, to PUF and BUR roof systems to include 48 wet mil base coat and 16 wet mils finish coat. All stages of preparation and application will be in accordance with manufacturer’s recommendations, and all accessory materials (to include fabric reinforcement) recommended by the manufacturer will be utilize and/or apply. Minimum Quantity per Building per delivery order: 100 SF.SPEC: 07 14 16SF2,000$0.00
A0058Furnish and install two coat, urethane, elastomeric roof coating, GEOGARD waterproofing system, to concrete roof systems to include 16 wet mil base coat and 16 wet mils finish coat. All stages of preparation and application will be in accordance with manufacturer’s recommendations, and all accessory materials (to include fabric reinforcement) recommended by the manufacturer will be utilize and/or apply. Minimum Quantity per Building per delivery order: 100 SF.SPEC: 07 14 16SF2,000$0.00
A0059Remove rust and scale from metal surfaces of the existing roofing system or other metal surface in areas which are to receive roof coatings/coatings by abrasive cleaning disks and/or wire brushing to manufacturer’s specified conditions unless otherwise indicated. Minimum Quantity per Building per delivery order: 25 SF.SPEC: 07 14 16SF100$0.00
Section 07 22 16.22 - Roof Board Insulation (Polyisocyanurate)
A0060Vapor retarder applied to roof deck surface by torch or hot mopped asphalt. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 22 16.22 paragraph 2.3 & 2.6.1SF25,000$0.00
A0061Gypsum Core Thermal Protection Board 1/2 inch glass mat gypsum core roof board or equivalent. Board to be factory primed. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 22 16.22SF10,000$0.00
A0062Gypsum Core Thermal Protection Board 5/8 inch glass mat gypsum core roof board or equivalent. Board to be factory primed. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 22 16.22SF10,000$0.00
A00632-inch to 2-1/2-inch polyisocyanurate insulation board system. Mechanically fasten to the substrate in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 22 16.22SF2,500$0.00
A00643-inch to 3-1/2-inch polyisocyanurate insulation board system. Mechanically fasten to the substrate in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 22 16.22SF10,000$0.00
A00652-inch to 2-1/2-inch polyisocyanurate insulation board system. Fully adhere insulation board in hot asphalt to appropriate substrate in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 22 16.22SF2,500$0.00
A00663-inch to 3-1/2-inch polyisocyanurate insulation board system. Fully adhere insulation board in hot asphalt to appropriate substrate in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 22 16.22SF10,000$0.00
A0067Tapered polyisocyanurate or approved equal insulation board system. Provide positive drainage with one (1) layer of factory tapered roof insulation boards, tapered at 1/4-inch per foot minimum, and fill boards as required. Secure total thickness by fully adhering all insulation boards with hot asphalt in accordance with manufacturer's recommendations. Average thickness of tapered insulation system composed of tapered and fill boards is 7.5 inches. Minimum Quantity per Building per delivery order: 300 SF.SPEC: 07 22 16.22SF3,000$0.00
A0068Tapered polyisocyanurate or approved equal insulation board system. Provide positive drainage with one (1) layer of factory tapered roof insulation boards, tapered at 1/4-inch per foot minimum, and fill boards as required. In accordance with manufacturer's recommendations, mechanically fasten insulation system to the substrate with successive layers of insulation attached mechanically or applied in hot asphalt. Average thickness of tapered insulation system composed of tapered and fill boards is 7.5 inches. Minimum Quantity per Building per delivery order: 300 SF.SPEC: 07 22 16.22SF3,000$0.00
A0069Preformed crickets and tapered edge strips of polyisocyanurate insulation board or approved equal. Provide positive drainage with One (1) layer of factory tapered roof insulation up to 1/2-inch per foot minimum slope. Fully adhere insulation board in hot asphalt to appropriate substrate. Average insulation thickness (6) inches. Minimum 50 Square Feet.SPEC: 07 22 16.22SF300$0.00
A0070Preformed cant strips of polyisocyanurate insulation board or approved equal. Incline face of cant strips to be 45 degrees with vertical height of (4) inch. Minimum Quantity per Building per delivery order: 20 LF. Secure in accordance with manufacturer's recommendations.SPEC: 07 22 16.22LF2,000$0.00
A0071Supplemental fastening of insulation to prepared metal/wood/gypsum/screwable deck substrate with penetrating type fasteners and preformed disks in accordance with manufacturer's recommendations. Provide 1 additional fastener per square foot for additional securement. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 22 16.22SF5,000$0.00
A0072Install insulation boards with nonflammable adhesives rather than hot asphalt. Unit cost of line item equals cost of application of one insulation board layer with nonflammable adhesives in $/SF, minus cost of application of one insulation board layer with hot asphalt in $/SF.SPEC: 07 22 16.22SF2,000$0.00
Section 07 22 16.23 - Roof Board Insulation (Expanded Polystyrene-EPS)
A00731-1/2-inch up to 3-1/2-inch EPS insulation board. Mechanically fastened or fully adhere in hot asphalt or with nonflammable adhesive to the substrate in accordance with manufacturer’s recommendations or per warranty recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 22 16.23SF5,000$0.00
Section 07 31 13 - Asphalt Shingles
A0074Self-adhering sheet underlayment; wrinkle free, on roof deck. Install in direction to shed water. Lap sides not less than 3-1/2 inches. Lap ends not less than 6 inches staggered 24 inches between courses. Roll laps with roller. Minimum Quantity per Building per delivery order: 100 SF.SPEC: 07 31 13 DWG. 4.01, 4.02 and 4.03SF5,000$0.00
A0075Fiberglass Reinforced Asphalt Shingles, Mineral granule-surfaced asphalt shingles, self-sealing, square tab, strip, fungus-resistant architectural shingles weighing NOMINAL 290 pounds per 100 SF in accordance with manufacturer’s recommendations. Install hip shingles, ridge shingles, and miscellaneous perimeter/ trim flashings. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 31 13 DWG. 4.01, 4.02 and 4.03SF5,000$0.00
A0076Standard high-density polypropylene or other UV-stabilized plastic ridge vent with non-woven geo-textile filter strips and external deflector baffles for use under ridge shingles in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 50 LF.SPEC: 07 31 13LF200$0.00
Section 07 32 00 - Concrete and Clay Tile Roofing
A0077Self-adhering sheet underlayment, granular surfaced; wrinkle free, on roof deck. Install at locations indicated on construction documents, lapped in direction to shed water. Lap sides not less than 3-1/2 inches. Lap ends not less than 6 inches staggered 24 inches between courses. Roll laps with roller.SPEC: 07 32 00 DWG. 5.01 through 5.11SF3,000$0.00
A0078New Roof: Molded or extruded-concrete roof tile units of shape and configuration matching existing conditions, with integral color, and free of surface imperfections. Include the installation of associated items, including tile end closures, rake and ridge tile, clips, cleats and miscellaneous perimeter and trim flashings. Provide with fastening for hurricane wind uplift criteria. Minimum Quantity per Building per delivery order: 300 SF. New roof tiles to match that of existing tiled roofs.SPEC: 07 32 00 DWG. 5.01 through 5.11SF1,500$0.00
A0079Existing Roof: Molded or extruded-clay roof tile units of shape and configuration matching existing conditions, with integral color, and free of surface imperfections. Include the installation of associated items, including tile end closures, rake and ridge tile , clips, cleats and miscellaneous perimeter and trim flashings. Provide with fastening for hurricane wind uplift criteria. Minimum Quantity per Building per delivery order: 30 SF. New roof tiles to match that of existing tiled roofs.SPEC: 07 32 00 DWG. 5.01 through 5.11SF1,500$0.00
Section 07 41 13 - Metal Roof Panels
A0080Coated (colored) Aluminum-Zinc Alloy-Coated Steel Roof panels secured with concealed or exposed fasteners in accordance with manufacturer's recommendations. Include the installation of associated items, including panel end closures, rake flashings, eave flashings, valleys, ridges, clips, cleats and miscellaneous perimeter and trim flashings. Minimum Quantity per Building per delivery order: 400 SF.SPEC: 07 41 13 DWG. 6.01, 6.03, 6.05, 6.07, 6.08, 6.11, 6.13, 6.15, 6.16 and 6.18SF2,500$0.00
Section 07 42 13 - Metal Wall Panels
A0081Furnish and install coated (colored) 18 gauge Aluminum-Zinc Alloy-Coated Steel Wall panels, secured with exposed fasteners in accordance with manufacturer’s recommendations. Include the installation of associated items, including panel end closures, corner flashings, clips, cleats and miscellaneous perimeter and trim flashings. Minimum Quantity per Building per delivery order: 500 SF.SPEC: 07 42 13 Dwg. 6.01 - 6.30SF500$0.00
Section 07 52 16.14 - SBS Modified Bituminous Membrane Roofing Hot-Mopped Asphalt Applied
A0082Furnish and install SBS modified bitumen (157 mils) highly reflective granular cap sheet with full mopping of hot asphalt - Type 4 asphalt over prepared surface of repair area as per manufacturer’s requirements. Minimum 50 SF.SPEC: 07 52 16.14SF5000$0.00
A0083Furnish and install SBS modified bitumen (157 mils) granular cap sheet with full mopping of hot asphalt - Type 4 asphalt over prepared surface of repair area as per manufacturer’s requirements. Minimum 50 SF.SPEC: 07 52 16.14SF20000$0.00
A0084Furnish and install (1) manufacturer's (118 mils) standard sanded modified bitumen membrane sheet (inter-ply or base ply) over prepared substrate as per manufacturer’s requirements. Apply sheet in full mopping of hot asphalt - Type 4 asphalt. Minimum 100 Square Feet.SPEC: 07 52 16.14SF5000$0.00
A0085Furnish and install (1) manufacturer's (157 mils) standard sanded modified bitumen membrane sheet (inter-ply or base ply) over prepared substrate as per manufacturer’s requirements. Apply sheet in full mopping of hot asphalt - Type 4 asphalt. Minimum 100 Square Feet.SPEC: 07 52 16.14SF20000$0.00
A00861/4" multi-ply, semi-rigid asphaltic roofing substrate board composed of a mineral fortified asphaltic core formed between two asphaltic saturated fiberglass liners recovery board over roof insulation; secure to existing roof substrate by hot mopping, cold adhesive, or mechanically fastening to the existing roof substrate per the manufacturer's recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 52 16.14SF5000$0.00
A00871/8" multi-ply, semi-rigid asphaltic roofing substrate board composed of a mineral fortified asphaltic core formed between two asphaltic saturated fiberglass liners recovery board over roof insulation; secure to existing roof substrate by hot mopping, cold adhesive, or mechanically fastening to the existing roof substrate per the manufacturer's recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 52 16.14SF20000$0.00
A0088157 mills polyester base ply over roof insulation; secure to existing roof substrate by mechanically fastening to existing roof substrate per the manufacturer's recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 52 16.14SF20000$0.00
A0089Furnish and install fiberglass base sheet secured with penetrating type fasteners and preformed disks or full mopping of Type 4 asphalt to deck/substrate as per manufacturer’s requirements. Minimum 100 SF.SPEC: 07 52 16.14SF5000$0.00
A0090Furnish and install SBS modified bituminous venting base sheet over concrete/gypsum deck substrate. Mechanically fasten (or torch) to deck/substrate per manufacturer’s requirements. Minimum 100 Square Feet.SPEC: 07 52 16.14SF3000$0.00
A0091SBS modified bitumen granular highly reflective (min. initial reflectivity value = 0.78), 2-ply modified bitumen membrane flashing system consisting of 157 mil cap sheet (minimum), strip flashing and sheet flashing in the angles formed where the roof deck abuts walls, curbs, ventilators, pipes, and other vertical surfaces, and where necessary to make the work watertight. Flashing plys secured with Type 4 hot mopped asphalt.SPEC: 07 52 16.14 DWG. 2.05 - 2.18SF500$0.00
A0092SBS modified bitumen granulated, 2-ply modified bitumen membrane flashing system consisting of 157 mil cap sheet (minimum), strip flashing and sheet flashing in the angles formed where the roof deck abuts walls, curbs, ventilators, pipes, and other vertical surfaces, and where necessary to make the work watertight. Flashing plys secured with Type 4 hot mopped asphalt.SPEC: 07 52 16.14 DWG. 2.05 - 2.18SF1000$0.00
A0093Asphalt roof deck primer. Minimum Quantity per Building per delivery order: 100 SF.SPEC: 07 52 16.14SF20000$0.00
A0094Install various roofing plys with manufacturer's recommended cold applied adhesive in lieu of hot mopping with Type-4 hot asphalt as indicated above. This line item will be used for roofs located in areas that do not permit use of hot asphalt kettles. Unit cost of line item equals cost of application 1-ply with cold applied adhesives in $/SF, minus cost of application of 1-ply with hot asphalt in $/SF. Minimum 100 SFSPEC: 07 52 16.14SF2000$0.00
Section 07 52 16.15 - SBS Modified Bituminous Membrane Roofing Torch Applied
A0095Furnish and install 'Torch-grade' 157 mil (min) SBS modified bitumen highly reflective granular cap sheet (min. initial reflectivity value = 0.78) torch applied over prepared surface of repair area per manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 50 SF.SPEC: 07 52 16.15SF2500$0.00
A0096Furnish and install 'Torch-grade' 157 mil (minimum) SBS modified bitumen granular cap sheet torch applied over prepared surface of repair area in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 50 SF.SPEC: 07 52 16.15SF5000$0.00
A0097Furnish and install 'Torch-grade' (1) manufacturer's standard smooth surface (118 mils) modified bitumen membrane sheet (inter-ply/base ply) over prepared substrate as per manufacturer’s requirements. Minimum 100 SF.SPEC: 07 52 16.15SF2500$0.00
A0098Furnish and install 'Torch-grade' (1) manufacturer's standard smooth surface (157 mils) modified bitumen membrane sheet (inter-ply/base ply) over prepared substrate as per manufacturer’s requirements. Minimum 100 SF.SPEC: 07 52 16.15SF5000$0.00
A0099157 mills polyester SBS modified bitumen base ply for use in approved multi-ply membrane and flashing assemblies for mechanical attachment to approved assemblies equal to SOPRAFIX 614. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 07 52 16.14SF10000$0.00
A0100Furnish and Install 'Torch Grade' 157 mil (minimum) SBS modified bitumen granular highly reflective (min. initial reflectivity value = 0.78), 2-ply modified bitumen membrane flashing system. Torch apply two-ply modified bitumen strip flashing and sheet flashing in the angles formed where the roof deck abuts walls, curbs, ventilators, pipes, and other vertical surfaces, and where necessary to make the work watertight.SPEC: 07 52 16.15 DWG. 2.05 - 2.21SF500$0.00
A0101Furnish and Install 'Torch Grade' 157 mil (minimum) SBS modified bitumen granulated, 2-ply modified bitumen membrane flashing system. Torch apply two-ply modified bitumen strip flashing and sheet flashing in the angles formed where the roof deck abuts walls, curbs, ventilators, pipes, and other vertical surfaces, and where necessary to make the work watertight.SPEC: 07 52 16.15 DWG. 2.05 - 2.21SF1000$0.00
Section 07 54 23 - Thermoplastic Membrane Roofing
A0102Fully adhered thermoplastic roof membrane, 45 mil ("Fibertite" or equivalent) over prepared roof deck/substrate, which includes perimeter edge, wall, parapet and expansion joint flashings. Secure sheet to deck/substrate with adhesives for application to insulation or underlayment in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 100 SF.SPEC: 07 54 23 DWG. 3.01 - 3.15SF1,000$0.00
A0103Mechanically fastened Thermoplastic roof membrane, 45 mil ("Fibertite" or equivalent), over prepared roof deck/substrate, which includes perimeter edge, wall, parapet and expansion joint flashings. Secure sheet with fasteners for application to insulation or underlayment in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 100 SF.SPEC: 07 54 23 DWG. 3.01 - 3.15SF10,000$0.00
A0104Fully adhered heat welded thermoplastic walkway membrane ("Fibertite" or equivalent) as recommended by roof membrane manufacturer. Minimum Quantity per Building per delivery order: 50 SF.SPEC: 07 54 23SF200$0.00
A0105Replace roof edge flashing with a fully adhered thermoplastic membrane flashing matching the existing membrane roofing system in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 50 SF.SPEC: 07 54 23 DWG. 3.01- 3.04SF50$0.00
A0106Fully adhered thermoplastic membrane flashing at base of curbs, equipment supports, mechanical piping, electrical conduit, and similar roof penetrations (greater than 4" diameter or 4" square); around parapets, curbs and walls as required; matching the existing membrane roofing system in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 50 SF.SPEC: 07 54 23 DWG. 3.05 - 3.08SF100$0.00
A0107Fully adhered thermoplastic membrane scupper or roof drain flashing in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 30 SF.SPEC: 07 54 23 DWG. 3.18SF30$0.00
A0108Fully adhered thermoplastic membrane flashing around round penetration, which includes VTR, mechanical piping, electrical and other conduits (less than 4” diameter or 4" square) in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 30 SF.SPEC: 07 54 23 DWG. 3.19 - 3.21SF30$0.00
A0109Fully adhered thermoplastic patch to existing damaged areas of thermoplastic membrane in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 30 SF.SPEC: 07 54 23SF30$0.00
Section 07 61 13.00 20 - Aluminum Roofing/Standing Seam Roofing
A0110Coated (colored) Aluminum Roof panels secured with concealed or exposed fasteners in accordance with manufacturer's recommendations. Include the installation of associated items, including panel end closures, rake flashings, eave flashings, valleys, ridges, clips, cleats and miscellaneous perimeter and trim flashings. Minimum Quantity per Building per delivery order: 400 SF.SPEC: 07 61 13.00 20 DWG. 6.01, 6.03, 6.05, 6.07, 6.08, 6.11, 6.13, 6.15, 6.16 and 6.18SF5,000$0.00
A0111Corrugated 0.032 aluminum “V Crimp” roofing (1/2" corrugations @ 12" O.C. w 2 intermediate smaller corrugations) w/ simulated aged galvalume Kynar500 finish for “fish camp” look. Replace all stainless steel clips fasteners, joists, hangars, & associated components/connectors. Min. = 120 S.F.SPEC: 07 61 13.00 20 DWG. 6.01, 6.03, 6.05, 6.07, 6.08, 6.11, 6.13, 6.15, 6.16 and 6.18SF2,000$0.00
Section 07 62 00 - Sheet Metal Flashing and Trim
A0112Stainless steel pitch pan in accordance with manufacturer’s recommendations. Solder all seams to form one continuous piece. Apply grout fill and 2-part pourable urethane sealer – sloped to provide runoff. Provide flashing collar or “umbrella” to penetration to protect the sealer from water intrusion and direct exposure sunlight. Minimum Quantity per Building per delivery order: 1 each at 4-inches deep, up to 12” square.SPEC: 07 62 00 DWG 1.04 and 1.09EA2$0.00
A0113Stainless steel gravel stop or drip edge fascia flashing assembly with a 4-inch to 6-inch face in accordance with manufacturer's recommendations. Provide continuous cleats of same material. Solder all corner and transition pieces. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00 DWG 7.01 and 7.38LF1,000$0.00
A0114Stainless steel gravel stop or drip edge fascia flashing assembly with a 6-inch to 9-inch face in accordance with manufacturer’s recommendations. Form stiffening rib in face of edge metal where face is greater than 6-inches. Provide continuous cleats of same material. Solder all corner and transition pieces. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00 DWG 7.01 and 7.38LF500$0.00
A0115Stainless steel skirt flashing extension or fascia in accordance with manufacturer's recommendations. Secure flashings with continuous cleats of same material. Stagger edge metal and fascia joints. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00 DWG 7.01 and 7.38LF500$0.00
A0116Stainless steel gutter assembly (size - 5” X 6”) include metal gutter hangars and straps in accordance with manufacturer’s recommendations. Solder joints in the gutter assembly. Provide expansion joints within the gutter assembly at maximum 40-ft intervals. Slope gutters for positive drainage to downspouts. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00 DWG 7.19 - 7.23LF1,000$0.00
A0117Stainless steel downspout (size - 4” x 5”), hangars and straps in accordance with manufacturer’s recommendation. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00 DWG 7.20 and 7.24LF1,000$0.00
A0118Stainless steel scupper assembly with fully soldered seams and joints in accordance with manufacturer’s recommendations. Average scupper size 6” x 8”. Minimum Quantity per Building per delivery order: 1 EA.SPEC: 07 62 00 DWG 7.25 - 7.28EA6$0.00
A0119Stainless steel parapet wall coping cap flashing on walls up to 12-inches in width with 4 inch vertical side flanges secured with continuous cleats. Provide standing seams at joints, continuous cleats along edges, and fully soldered termination and transition pieces in accordance with manufacturer’s recommendations. Cap flashing must be supported by a solid substrate. Slope cap inward to the roof for runoff. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00 DWG 7.05 - 7.10LF500$0.00
A0120Stainless steel surface-mounted reglet in accordance with manufacturer’s recommendations. Provide reglet with slotted holes for fastening to substrate, with neoprene or other suitable weatherproofing washers and with channel for sealant at top edge. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00 DWG. 7.33LF500$0.00
A0121Fabricate and install or furnish and install manufactured stainless steel expansion joint assembly on joints up to 12-inches as per manufacturer’s requirements. Provide reglet with slotted holes for fastening to substrate, with neoprene or other suitable weatherproofing washers and with channel for sealant at top edge. Minimum (20) Linear Feet.SPEC: 07 62 00 DWG. 2.13LF25$0.00
A0122Provide and install stainless steel valley flashing centrally in roof valleys, free of longitudinal seams, of a width sufficient to extend not less than eight (8) inches under the roof covering on each side of the valley.SPEC: 07 62 00LF40$0.00
A0123Provide and install stainless steel stepped flashing where sloping roof surfaced with shingles abut vertical surfaces.SPEC: 07 62 00LF40$0.00
A0124Stainless steel ‘L’ Type Flashing with continuous cleat. Minimum Quantity per Building per delivery order: 10 LF.SPEC: 07 62 00 DWG 4.12 and 7.18LF50$0.00
A0125Stainless steel ‘L’ Type Flashing without continuous cleat. Minimum Quantity per Building per delivery order: 10 LF.SPEC: 07 62 00 DWG 4.13 and 4.14LF50$0.00
A0126Stainless steel ‘J’/'T' Type Flashing with or without continuous receiver. Minimum Quantity per Building per delivery order: 10 LF.SPEC: 07 62 00LF30$0.00
A0127Aluminum surface-mounted termination bar in accordance with manufacturer’s recommendations. Provide termination bar with slotted holes for fastening to substrate, with neoprene or other suitable weatherproofing washers and with channel for sealant at top edge. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00 DWG 7.30LF1,000$0.00
A0128Fabricate and install aluminum, or aluminum-zinc alloy-coated steel with factory-applied Kynar 500 finish eave flashing, or drip edge fascia flashing assembly with a 4-inch to 6-inch face as per manufacturer’s requirements. Provide continuous cleats of same material. Minimum (20) Linear Feet.SPEC: 07 62 00 DWG 6.01 and 6.02LF500$0.00
A0129Fabricate and install aluminum, or aluminum-zinc alloy-coated steel with factory-applied Kynar 500 finish soffit as per manufacturer’s requirements. Minimum (20) Square Feet.SPEC: 07 62 00 DWG 6.05 and 6.10SF1,000$0.00
A0130Copper gravel stop or drip edge flashing assembly with a 4-inch to 9-inch face in accordance with manufacturer’s recommendations. Form stiffening rib in face of edge metal where face is greater than 6-inches. Provide continuous cleats of same material. Solder all corner and transition pieces. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00LF200$0.00
A0131Copper skirt flashing extension or fascia in accordance with SMACNA manual. Secure flashings with continuous cleats of same material. Stagger edge metal and fascia joints. Provide 10" section of copper sheet metal bent up to 5 times to form profile and accept cleat retainers. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00LF200$0.00
A0132Copper gutter assembly (size - 5” X 6” ) include metal gutter hangars and straps in accordance with manufacturer's recommendations. Solder joints in the gutter assembly. Provide expansion joints within the gutter assembly at maximum 40-ft intervals. Slope gutters for positive drainage to downspouts. Minimum Quantity per Building per delivery: 20 LF.SPEC: 07 62 00; DWG: 7.19 - 7.23LF200$0.00
A0133Copper downspout (size - 4” x 5”), hangars and straps in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00; DWG 7.20 and 7.24LF200$0.00
A0134Copper parapet wall coping cap flashing on walls. Provide standing seams at joints, continuous cleats along edges, and fully soldered termination and transition pieces in accordance with manufacturer’s recommendations. Cap flashing must be supported by a solid substrate. Slope cap inward to the roof for runoff. Average wall width 12". Minimum Quantity per Building per delivery order: 20 LF.SPEC: 07 62 00 DWG:7.05 - 7.10LF50$0.00
A0135Copper valley flashing centrally in roof valleys, free of longitudinal seams, of a width sufficient to extend not less than 8-inches under the roof covering on each side of the valley.SPEC: 07 62 00LF50$0.00
A0136Copper step flashing where sloping roof surface with shingles abut vertical surfaces.SPEC: 07 62 00LF50$0.00
A0137Copper 'L' Type Flashing. Provide with continuous cleat as required to meet current uplift requirement. Minimum Quantity per Building per delivery order: 10 LF.SPEC: 07 62 00 DWG 4.12 and 7.18LF50$0.00
A0138Copper 'J'/ 'T' Type Flashing. with continuous cleat receiver cleat as required to meet current uplift requirement. Minimum Quantity per Building per delivery order: 10 LF.SPEC: 07 62 00LF50$0.00
A0139Lead sheet metal flashing sleeve at VTR or plumbing vents in accordance with manufacturer’s recommendations.SPEC: 07 62 00 DWG 7.35EA15$0.00
A0140Clad aluminum flashing membrane along edge metal for thermoplastic roof system in accordance with manufacturer’s recommendations.SPEC: 07 62 00SF750$0.00
A0141Clad scuppers with aluminum flashing on thermoplastic roof system up to 12"x 12"x 6" tall sides, of a width sufficient to extend min. 4" over the roof covering. Minimum Quantity per Building per delivery order: 2 EA.SPEC: 07 62 00EA20$0.00
Section 07 92 00 - Joint Sealants
A0142Replace/add wall floor joint sealant (.25'' to .5'' width). Min. = 50 LFSPEC: 07 92 00;
3.3LF500$0.00
Division 08 - Openings

(Unless otherwise noted, items this division shall be "furnished and installed".)

Section 08 61 00 - Unit Skylights
A0143Factory-assembled hurricane rated, Miami Dade County Approved/Certified, impact resistant skylight unit which includes glazing, extruded-aluminum glazing retainers, gaskets, curbing, sealant, associated framing, flashing necessary for water tight assembly in accordance with manufacturer's recommendations. Average size of skylight 24" x 48". Minimum Quantity per Building per delivery order: 1 EA.SPEC: 08 61 00EA2$0.00
Division 08 - Openings

(Unless otherwise noted, includes "fabricated/furnished & installed w associated accessories") "Min. =" means Minimum Quantity per Building per Delivery Order

Section 08 56 53 - Blast Resistant Tempered Glass
A0144Replace window assembly w blast resistant window assemblies. ASTM F-1642-04, GSA TS01 Factory made window assemblies meeting min. performance criteria of 3a w protection level High & haz level low. Min. = 16 S.F. Includes sealant & all accessories.SPEC: 08 56 53;
3.1SF250$0.00
A0145Replace window assembly w Miami Dade hurricane-rated window assembly Min. = 16 S.F. Includes sealant & all accessories.SPEC: 08 56 53;
3.1SF200$0.00
Section 08 81 00 - Glazing
A0146Replace individual panes of glass in single/double pane windows or laminated glass in store front applications up to 54" by 72". Includes sealant & all accessories.SPEC: 08 81 00;
3.2SF150$0.00
Division 09 - Finishes

Unless otherwise noted, items in this division include removal and disposal in accordance with Federal, State, County and City ordinances. Includes the materials, labor, equipment & any other resources or steps required to safely perform the required surface preparation & painting; including cleaning, feathering of edges, minor spackling, scaffolding, & containment (excluding lead based paint) for protection of surrounding areas.

Section 09 29 00 - Gypsum Board
A0147Replace gypsum board w texture, medium texture orange peel. Min. = 100 SFSPEC 09 29 00;
3.4.2.1SF750$0.00
A0148Replace 4" rubber/vinyl wall base. Min. = 100 LFSPEC: 09 29 00;
3.6LF250$0.00
Section 09 51 00 - Acoustical Ceilings
A0149Replace/add acoustical ceiling panel, 2' by 2' or 2' by 4'. Min. = 500 SFSPEC: 09 51 00;
3.1.3SF500$0.00
Section 09 90 01 - Exterior Painting
A0150Remove and clean substrates of substances that could impair bonding of paint materials, including but not limited to, dirt, oil, grease, release agents, curing compounds, efflorescence, chalk and incompatible paints, in accordance with manufacturer's recommendations. Comply with manufacturer's written instructions and recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 09 90 01SF500$0.00
A0151Apply primer to substrates to receive paint materials in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 09 90 01SF500$0.00
A0152Apply intermediate coat or topcoat paint materials to metal substrates in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 200 SF.SPEC: 09 90 01SF500$0.00
A0153Replace caulk on doors, windows, roof/wall reglect, or bldg. component. Min. = 4 L.F.SPEC: 09 90 01;
3.10LF2,500$0.00
A0154Acrylic latex overcoat on concrete/masonry block w moderately weathered acrylic latex. Min. = 150 S.F.SPEC: 09 90 01SF15,000$0.00
A0155Elastomeric overcoat on concrete/masonry block w moderately weathered acrylic latex. Min. = 150 S.F.SPEC: 09 90 01SF8,000$0.00
A0156Elastomeric overcoat on concrete/masonry block w moderately weathered elastomeric. Min. = 150 S.F.SPEC: 09 90 01SF8,000$0.00
A0157Pressure wash (LPWC), incl. mildew treatment & removal. Min. = 50 S.F.SPEC: 09 90 01;
3.9.10.1SF15,000$0.00
A0158Repair masonry/stucco/concrete cracks (up to 3/8" width). Min. = 50 L.F.SPEC: 09 90 01;
3.11.2LF500$0.00
A0159Patch masonry/concrete/stucco surfaces. Min. = 50 S.F.SPEC: 09 90 01;
3.11.2SF500$0.00
A0160Repair spalling concrete w/exposed reinforcement bar. Min. = 10 C.F.SPEC: 09 90 01;
3.11.1.2CF200$0.00
A0161Repair EIFS (synthetic stucco). Min. = 50 S.F.SPEC: 09 90 01;
3.11.3SF100$0.00
A0162Repair Portland cement stucco. Min. = 50 S.F.SPEC: 09 90 01;
3.11.2SF200$0.00
A0163Route crack to 1/4"-3/8" width & clean to prepare for sealing. Min. = 50 L.F.SPEC: 09 90 01;
3.11.2LF100$0.00
Division 22 - Plumbing

(Unless otherwise noted, items in this division include "removal and disposal" in accordance with Federal, State, County and City ordinances. "Furnish/fabricate and install" new components.)

Section 22 05 00 - General Plumbing Requirements