Exhibit 6 - Plans~11.pdf

PDF 565 KB Posted

Attached to
Manning MS Station Roof replacement
Solicitation number
S-73000-00017781
Issued by
Oregon

About this file

This document is a set of plans and specifications for the Manning MS Station Roof Replacement project in Oregon. The project scope includes the removal of the existing metal roof, insulation barrier, and gutters, with subsequent installation of insulated metal roof panels and new gutters. The plans provide detailed technical specifications, dimensional drawings, and construction details necessary for bidders to understand the full scope of work and submit accurate proposals for this roofing replacement project.

The document serves as the primary reference material for contractors preparing bids on this state and local contract opportunity. It contains the architectural and construction specifications that establish the standards for materials, workmanship, and installation procedures required for the roof replacement work. Bidders must review these plans in conjunction with the project description and scope of work to develop comprehensive bids that address all aspects of the existing roof removal and new roof system installation.

View the file

Other files

File Type Posted
00017781_Addendum One.docx DOCX document
00017781_Invitation to Bid draft.docx DOCX document
Revised Exhibit 5 - Specifications.docx DOCX document
Attachment B - Sample Contract~18.docx DOCX document
Revised Exhibit 7 - Statement of Work.doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WALLOWA

UNION

UMATILLA

MORROW

GILLIAM

SHERMANWASCO

HOOD

RIVER

CLACKAMAS

MULTNOMAH

COLUMBIA

CLATSOP

TILLAMOOK

WASHINGTON

YAMHILL

POLK

LINCOLN

BENTON

LINN

MARION

LANE

DOUGLAS

COOS

CURRY

JOSEPHINE

JACKSON

KLAMATH

LAKE

HARNEY

MALHEUR

CROOK

JEFFERSON WHEELER

GRANT

BAKER

DESCHUTES

26 JOHN

DAY

THE

DALLES

PENDLETON

LA

GRANDE

BAKER

CITY

ONTARIO

BURNS

BEND

KLAMATH

FALLS

PORTLAND

SALEM

EUGENE

ROSEBURG

MEDFORD

COOS

BAY

NEWPORT

ASTORIA

FLORENCE

CORVALLIS

ALBANY

ASHLAND

LAKEVIEW

ODOT MANNING

MAINTENANCE STATION

STORAGE BUILDING PROJECT

LOCATION, SEE DRAWING A101

REDUCED 50%

WHEN PRINTED

AT 11" x 17"

TH

IS

D R

AW

IN

G

IS

R

ED

U C

ED

IF

B O

R D

ER

IS

N O

T

/2

" x

2"

F4340310

ODOT MANNING MAINTENANCE STATION

STORAGE BUILDING ROOF REPLACEMENT

48400 US HIGHWAY 26, MANNING, OR 97125 3

08/20/26

FRANCO

ODOT MANNING MAINTENANCE STATION

STORAGE BUILDING ROOF REPLACEMENT

48400 US HIGHWAY 26, MANNING, OR 97125

1. ALL WORK SHALL CONFORM TO APPLICABLE CODES, LAWS AND ORDINANCES OF THE JURISDICTION HAVING AUTHORITY.

2. DO NOT SCALE THE DRAWINGS.

3. CONTRACTOR SHALL MAKE A SITE VISIT AND EXAMINE EXISTING CONDITIONS PRIOR TO PROVIDING A BID. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF ODOT THROUGH A REQUEST FOR CLARIFICATION AS SET

FORTH IN THE BID DOCUMENTS.

4. CLARIFICATIONS SHALL BE REQUESTED IN WRITING PRIOR TO ANY INSTALLATION. INCORRECT INSTALLATIONS SHALL BE

CORRECTED AT NO ADDITIONAL COST TO ODOT.

5. ALL WORK SHOWN IS TO BE BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED AS BEING BY ODOT OR BY OTHERS. ALL MATERIALS SHOWN ARE TO BE PROVIDED BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED AS EXISTING OR

PROVIDED BY ODOT.

6. DRAWINGS ARE SCHEMATIC IN NATURE. MAJOR COMPONENTS AND EQUIPMENT ARE SHOWN ON THE DRAWINGS.

CONTRACTOR SHALL SUPPLY AND INSTALL ALL MINOR COMPONENTS AND MATERIALS NECESSARY TO PROVIDE A COMPLETE AND FUNCTIONAL PROJECT WHETHER OR NOT ALL SUCH COMPONENTS ARE NOTED IN THE DRAWINGS AND

SPECIFICATIONS.

7. PLANS AND SPECIFICATIONS CALL OUT SPECIFIC MAKES AND MODELS OF EQUIPMENT IN SOME LOCATIONS.

SUBSTITUTION REQUESTS SHALL BE MADE DURING THE BID PROCESS. ODOT SHALL AT ITS SOLE DISCRETION DETERMINE THE ACCEPTABILITY OF SUBSTITUTIONS. NO SUBSTITUTIONS SHALL BE INSTALLED WITHOUT PRIOR WRITTEN APPROVAL

FROM THE ODOT CONSTRUCTION PROJECT MANAGER.

8. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED

INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS.

9. CLEAN ENTIRE WORK AREA AT CONCLUSION OF PROJECT TO THE SATISFACTION OF THE ODOT PROJECT MANAGER.

GENERAL CONSTRUCTION NOTES

T101 TITLE SHEET

A101 SITE PLAN AND ROOF PLAN

A102 DETAILS

SHEET INDEX

0 200'

LOCAL VICINITY PLAN

SCALE: 1" = 200'

STATE VICINITY MAP

SCALE: N.T.S.

TITLE SHEET T101

MANNING

CODE INFORMATION:

S-1 OCCUPANCY

TYPE OF CONSTRUCTION: II-B

STORAGE BUILDING: 4,830 SF

TO SEASIDE - 50.7 MILES

TO PORTLAND - 28.1 MILES

PROJECT DESCRIPTION:

THE PROJECT INVOLVES THE REMOVAL AND

REPLACEMENT OF EXISTING ROOFING, INSULATION,

GUTTERS, DOWNSPOUTS, AND ACCESSORIES. NEW

ROOFING CONSIST OF INSULATED METAL PANELS

WITH A MINIMUM R-VALUE OF 40.

SEE EXHIBIT 5 STATEMENT OF WORK FOR A

COMPLETE DESCRIPTION OF THE WORK.

ALL PROJECT WORKS IS TO BE IN ACCORDANCE WITH

OREGON STRUCTURAL SPECIALITY CODE (OSSC)

CHAPTER 15 SECTION 1512 RE-ROOFING.

SUNSET HIGHWAY - HWY 26

EQUIPMENT

STORAGE

F4340312

MAINTENANCE

BUILDING

F4340305

STORAGE

F4340308

SAND SHED

F2400302

ASPHALT

PAVEMENT

GRAVEL

YARD

ASPHALT

PAVEMENT

ENCLOSED

STORAGE

F4340310

PL

LP

PL

PL

PL PL

PL

ASPHALT

PAVEMENT

ASPHALT/ GRAVEL

YARD

GATE

FUEL AREA

HERB STORAGE

F4340311

OLD FUEL

F4340306

GATE

DE-ICER

TANKS

GENERATOR

F4340313

POWDER MAG

F4340307

RIDGE CAP,

SEE DETAIL

POWERED

EXHAUST FAN

TO REMAIN,

TYPICAL

50'-0"

REMOVE EXISTING

SKYLIGHTS, TYP.

TYP

A102

TYP

A102

96'-0"

NOTE 1

NOTE:

1. CHANGE IN ROOF PITCH. CONTRACTOR TO

SUBMIT FLASHING AND CONNECTION DETAIL.

2. PORCH ROOF AT WEST SIDE OF BUILDING TO BE

INCLUDED IN THE BID. SIZE TO BE VERIFIED

DURING PRE-BID.

NOTE 2

A102

REDUCED 50%

WHEN PRINTED

AT 11" x 17"

TH

IS

D R

AW

IN

G

IS

R

ED

U C

ED

IF

B O

R D

ER

IS

N O

T

/2

" x

2"

F4340310

ODOT MANNING MAINTENANCE STATION

STORAGE BUILDING ROOF REPLACEMENT

48400 US HIGHWAY 26, MANNING, OR 97125 3

08/20/26

FRANCO

SITE PLAN AND ROOF PLAN A101

0 50'

SITE PLAN

SCALE: 1" = 50'

STORAGE ROOF PLAN

SCALE: 3/32" = 1'-0"

BIRD BLOCK PER IMP MFGR

3"

ROOF PANEL CLIP WITH

FASTENING PER IMP MFGR.

GUTTER HANGER

FASTENER PER IMP MFGR.

GUTTER

TRIM

BUTYL TAPE

SEALANT STRIP

UNDER GUTTER

STRAP

EXISTING

EAVE STRUT

EXISTING METAL WALL PANEL

OUTSIDE FOAM CLOSURE

TO FIT EXISTING METAL

WALL PANEL PROFILE

RAKE FASCIA

REMOVE STANDING SEAM

OVERLAP AS REQUIRED

STANDING SEAM TRIM

SUPPORT PER IMP MFGR.

POP RIVET PER

IMP MFGR.

FASTENING PER IMP MFGR.

BUTYL TAPE SEALANT PER IMP MFGR.

EXISTING PURLIN

BUTYL TAPE SEALANT

PER IMP MFGR.

EXISTING METAL

WALL PANEL

ROOF PANEL CLIP WITH

FASTENING PER IMP MFGR.

FASTEN PER IMP MFGR.

OUTSIDE CLOSURE STRIP SET IN

BUTYL TAPE SEALANT AT TOP

AND BOTTOM

METAL CLOSURE SET IN BUTYL

TAPE SEALANT AT TOP AND BOTTOM

FASTENING PER IMP MFGR.

FILL GAP CONTINUOUSLY WITH

TWO-PART FOAMED-IN-PLACE

URETHANE

EXISTING PURLIN, TYP.

BUTYL TAPE SEALANT

OUTSIDE RIDGE

REDUCED 50%

WHEN PRINTED

AT 11" x 17"

TH

IS

D R

AW

IN

G

IS

R

ED

U C

ED

IF

B O

R D

ER

IS

N O

T

/2

" x

2"

F4340310

ODOT MANNING MAINTENANCE STATION

STORAGE BUILDING ROOF REPLACEMENT

48400 US HIGHWAY 26, MANNING, OR 97125 3

08/20/26

FRANCO

SECTION AND DETAILS A102

GABLE END

SCALE: N.T.S.

A102

ROOF EAVE WITH GUTTER

SCALE: N.T.S.

A102

RIDGE

SCALE: N.T.S.

A102

F4340310 - 02_MANNING STORAGE ROOF REPLACEMENT_PLAN T101.pdf
F4340310 - 02_MANNING STORAGE ROOF REPLACEMENT_PLAN A101.pdf
F4340310 - 02_MANNING STORAGE ROOF REPLACEMENT_PLAN A102.pdf

File details come from the government source that posted it. Updated .