Exhibit 6 - Plans~11.pdf
PDF 565 KB Posted
- Attached to
- Manning MS Station Roof replacement
- Solicitation number
- S-73000-00017781
- Issued by
- Oregon
About this file
This document is a set of plans and specifications for the Manning MS Station Roof Replacement project in Oregon. The project scope includes the removal of the existing metal roof, insulation barrier, and gutters, with subsequent installation of insulated metal roof panels and new gutters. The plans provide detailed technical specifications, dimensional drawings, and construction details necessary for bidders to understand the full scope of work and submit accurate proposals for this roofing replacement project.
The document serves as the primary reference material for contractors preparing bids on this state and local contract opportunity. It contains the architectural and construction specifications that establish the standards for materials, workmanship, and installation procedures required for the roof replacement work. Bidders must review these plans in conjunction with the project description and scope of work to develop comprehensive bids that address all aspects of the existing roof removal and new roof system installation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 00017781_Addendum One.docx | DOCX document | |
| 00017781_Invitation to Bid draft.docx | DOCX document | |
| Revised Exhibit 5 - Specifications.docx | DOCX document | |
| Attachment B - Sample Contract~18.docx | DOCX document | |
| Revised Exhibit 7 - Statement of Work.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALLOWA
UNION
UMATILLA
MORROW
GILLIAM
SHERMANWASCO
HOOD
RIVER
CLACKAMAS
MULTNOMAH
COLUMBIA
CLATSOP
TILLAMOOK
WASHINGTON
YAMHILL
POLK
LINCOLN
BENTON
LINN
MARION
LANE
DOUGLAS
COOS
CURRY
JOSEPHINE
JACKSON
KLAMATH
LAKE
HARNEY
MALHEUR
CROOK
JEFFERSON WHEELER
GRANT
BAKER
DESCHUTES
26 JOHN
DAY
THE
DALLES
PENDLETON
LA
GRANDE
BAKER
CITY
ONTARIO
BURNS
BEND
KLAMATH
FALLS
PORTLAND
SALEM
EUGENE
ROSEBURG
MEDFORD
COOS
BAY
NEWPORT
ASTORIA
FLORENCE
CORVALLIS
ALBANY
ASHLAND
LAKEVIEW
ODOT MANNING
MAINTENANCE STATION
STORAGE BUILDING PROJECT
LOCATION, SEE DRAWING A101
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4340310
ODOT MANNING MAINTENANCE STATION
STORAGE BUILDING ROOF REPLACEMENT
48400 US HIGHWAY 26, MANNING, OR 97125 3
08/20/26
FRANCO
ODOT MANNING MAINTENANCE STATION
STORAGE BUILDING ROOF REPLACEMENT
48400 US HIGHWAY 26, MANNING, OR 97125
1. ALL WORK SHALL CONFORM TO APPLICABLE CODES, LAWS AND ORDINANCES OF THE JURISDICTION HAVING AUTHORITY.
2. DO NOT SCALE THE DRAWINGS.
3. CONTRACTOR SHALL MAKE A SITE VISIT AND EXAMINE EXISTING CONDITIONS PRIOR TO PROVIDING A BID. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF ODOT THROUGH A REQUEST FOR CLARIFICATION AS SET
FORTH IN THE BID DOCUMENTS.
4. CLARIFICATIONS SHALL BE REQUESTED IN WRITING PRIOR TO ANY INSTALLATION. INCORRECT INSTALLATIONS SHALL BE
CORRECTED AT NO ADDITIONAL COST TO ODOT.
5. ALL WORK SHOWN IS TO BE BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED AS BEING BY ODOT OR BY OTHERS. ALL MATERIALS SHOWN ARE TO BE PROVIDED BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED AS EXISTING OR
PROVIDED BY ODOT.
6. DRAWINGS ARE SCHEMATIC IN NATURE. MAJOR COMPONENTS AND EQUIPMENT ARE SHOWN ON THE DRAWINGS.
CONTRACTOR SHALL SUPPLY AND INSTALL ALL MINOR COMPONENTS AND MATERIALS NECESSARY TO PROVIDE A COMPLETE AND FUNCTIONAL PROJECT WHETHER OR NOT ALL SUCH COMPONENTS ARE NOTED IN THE DRAWINGS AND
SPECIFICATIONS.
7. PLANS AND SPECIFICATIONS CALL OUT SPECIFIC MAKES AND MODELS OF EQUIPMENT IN SOME LOCATIONS.
SUBSTITUTION REQUESTS SHALL BE MADE DURING THE BID PROCESS. ODOT SHALL AT ITS SOLE DISCRETION DETERMINE THE ACCEPTABILITY OF SUBSTITUTIONS. NO SUBSTITUTIONS SHALL BE INSTALLED WITHOUT PRIOR WRITTEN APPROVAL
FROM THE ODOT CONSTRUCTION PROJECT MANAGER.
8. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS.
9. CLEAN ENTIRE WORK AREA AT CONCLUSION OF PROJECT TO THE SATISFACTION OF THE ODOT PROJECT MANAGER.
GENERAL CONSTRUCTION NOTES
T101 TITLE SHEET
A101 SITE PLAN AND ROOF PLAN
A102 DETAILS
SHEET INDEX
0 200'
LOCAL VICINITY PLAN
SCALE: 1" = 200'
STATE VICINITY MAP
SCALE: N.T.S.
TITLE SHEET T101
MANNING
CODE INFORMATION:
S-1 OCCUPANCY
TYPE OF CONSTRUCTION: II-B
STORAGE BUILDING: 4,830 SF
TO SEASIDE - 50.7 MILES
TO PORTLAND - 28.1 MILES
PROJECT DESCRIPTION:
THE PROJECT INVOLVES THE REMOVAL AND
REPLACEMENT OF EXISTING ROOFING, INSULATION,
GUTTERS, DOWNSPOUTS, AND ACCESSORIES. NEW
ROOFING CONSIST OF INSULATED METAL PANELS
WITH A MINIMUM R-VALUE OF 40.
SEE EXHIBIT 5 STATEMENT OF WORK FOR A
COMPLETE DESCRIPTION OF THE WORK.
ALL PROJECT WORKS IS TO BE IN ACCORDANCE WITH
OREGON STRUCTURAL SPECIALITY CODE (OSSC)
CHAPTER 15 SECTION 1512 RE-ROOFING.
SUNSET HIGHWAY - HWY 26
EQUIPMENT
STORAGE
F4340312
MAINTENANCE
BUILDING
F4340305
STORAGE
F4340308
SAND SHED
F2400302
ASPHALT
PAVEMENT
GRAVEL
YARD
ASPHALT
PAVEMENT
ENCLOSED
STORAGE
F4340310
PL
LP
PL
PL
PL PL
PL
ASPHALT
PAVEMENT
ASPHALT/ GRAVEL
YARD
GATE
FUEL AREA
HERB STORAGE
F4340311
OLD FUEL
F4340306
GATE
DE-ICER
TANKS
GENERATOR
F4340313
POWDER MAG
F4340307
RIDGE CAP,
SEE DETAIL
POWERED
EXHAUST FAN
TO REMAIN,
TYPICAL
50'-0"
REMOVE EXISTING
SKYLIGHTS, TYP.
TYP
A102
TYP
A102
96'-0"
NOTE 1
NOTE:
1. CHANGE IN ROOF PITCH. CONTRACTOR TO
SUBMIT FLASHING AND CONNECTION DETAIL.
2. PORCH ROOF AT WEST SIDE OF BUILDING TO BE
INCLUDED IN THE BID. SIZE TO BE VERIFIED
DURING PRE-BID.
NOTE 2
A102
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4340310
ODOT MANNING MAINTENANCE STATION
STORAGE BUILDING ROOF REPLACEMENT
48400 US HIGHWAY 26, MANNING, OR 97125 3
08/20/26
FRANCO
SITE PLAN AND ROOF PLAN A101
0 50'
SITE PLAN
SCALE: 1" = 50'
STORAGE ROOF PLAN
SCALE: 3/32" = 1'-0"
BIRD BLOCK PER IMP MFGR
3"
ROOF PANEL CLIP WITH
FASTENING PER IMP MFGR.
GUTTER HANGER
FASTENER PER IMP MFGR.
GUTTER
TRIM
BUTYL TAPE
SEALANT STRIP
UNDER GUTTER
STRAP
EXISTING
EAVE STRUT
EXISTING METAL WALL PANEL
OUTSIDE FOAM CLOSURE
TO FIT EXISTING METAL
WALL PANEL PROFILE
RAKE FASCIA
REMOVE STANDING SEAM
OVERLAP AS REQUIRED
STANDING SEAM TRIM
SUPPORT PER IMP MFGR.
POP RIVET PER
IMP MFGR.
FASTENING PER IMP MFGR.
BUTYL TAPE SEALANT PER IMP MFGR.
EXISTING PURLIN
BUTYL TAPE SEALANT
PER IMP MFGR.
EXISTING METAL
WALL PANEL
ROOF PANEL CLIP WITH
FASTENING PER IMP MFGR.
FASTEN PER IMP MFGR.
OUTSIDE CLOSURE STRIP SET IN
BUTYL TAPE SEALANT AT TOP
AND BOTTOM
METAL CLOSURE SET IN BUTYL
TAPE SEALANT AT TOP AND BOTTOM
FASTENING PER IMP MFGR.
FILL GAP CONTINUOUSLY WITH
TWO-PART FOAMED-IN-PLACE
URETHANE
EXISTING PURLIN, TYP.
BUTYL TAPE SEALANT
OUTSIDE RIDGE
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4340310
ODOT MANNING MAINTENANCE STATION
STORAGE BUILDING ROOF REPLACEMENT
48400 US HIGHWAY 26, MANNING, OR 97125 3
08/20/26
FRANCO
SECTION AND DETAILS A102
GABLE END
SCALE: N.T.S.
A102
ROOF EAVE WITH GUTTER
SCALE: N.T.S.
A102
RIDGE
SCALE: N.T.S.
A102
| F4340310 - 02_MANNING STORAGE ROOF REPLACEMENT_PLAN T101.pdf |
| F4340310 - 02_MANNING STORAGE ROOF REPLACEMENT_PLAN A101.pdf |
| F4340310 - 02_MANNING STORAGE ROOF REPLACEMENT_PLAN A102.pdf |
File details come from the government source that posted it. Updated .