Consillium_SAL_R1a_Speed_Log_Manual.pdf

PDF 7 MB Posted

Attached to
Drydock Repairs to NOAA Ship OKEANOS EXPLORER
Solicitation number
EA133M-15-RP-0056
Issued by

About this file

Consillium

View the file

Other files

File Type Posted
SF_30 _Amend_0006.pdf PDF
Revised_Pricing_Schedule.pdf PDF
SF_30 _Amend_0005.pdf PDF
Revised_Pricing_Schedule.pdf PDF
Amendment_0004.pdf PDF
Amendment_003.pdf PDF
EX_FY_16_Drydock_Specs_(Rev_6).pdf PDF
633-6233582.pdf PDF
Elinca_System_Operation_Manual.pdf PDF
OE-123-002.pdf PDF
Amendment_002.pdf PDF
EX_FY_16_Drydock_Specs_(Rev_5).pdf PDF
Amendment_0001.pdf PDF
RFP_ATTACHMENT_J.4.pdf PDF
Attachment_J7.pdf PDF
EX_FY_16_Drydock_Specs_(Rev_3).pdf PDF
RFP.pdf PDF
RFP_ATTACHMENT_J.5.pdf PDF
RFP_ATTACHMENT_J.2.pdf PDF
RFP_ATTACHMENT_J.3.pdf PDF
RFP_ATTACHMENT_J.6.pdf PDF
000-2C.pdf PDF
s2906.pdf PDF
Drydock_Worksheet.pdf PDF
s1600.pdf PDF
Siimrad_Transducer_installation_guidlines_03776_-_160164.pdf PDF
Mounting_Rings.pdf PDF
Simrad_EK60_blockdiagram.pdf PDF
Clamping_Rings.pdf PDF
184_NAVIGATION_SYSTEM_ALIGNMENT.pdf PDF
Transducer_specification_sheets.pdf PDF
Anti-fouling_paint_Simrad_approved.pdf PDF
512-6233801.pdf PDF
OE-165-101_Rev_A.pdf PDF
EX_FY_16_Drydock_Specs_(Rev_3).pdf PDF
300-1.pdf PDF
Thrustmaster_Operators_Manual__Hydraulic_Tunnel_Thruster_Model_36TT250-AL_(Stern_Thrusters).pdf PDF
529-6233819.pdf PDF
437-6233672.pdf PDF
OE-303-101.pdf PDF
OE-528-101.pdf PDF
Propulsion_Motor_Thrust_and_Aft_Journal_Bearings_Instruction_Manual.pdf PDF
ROV_Pit_Hatch_Cover_Drawing.pdf PDF
Thrustmaster_Operator's_Manual_-_Retractable_Azmuthing_Thruster_Model_TH-500MLRT.pdf PDF
588-6233962.pdf PDF
631-3B.pdf PDF
581-6233594 Revision F.pdf PDF
512-6233797.pdf PDF
UT_Readings_12-9-10.pdf PDF
OE-123-101 Tank Sounding Tables.pdf PDF
Show 40 more

Latest 50 of 75 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

© Consilium Marine & Safety AB • P.O. Box 5021 • SE-131 05 NACKA • SWEDEN Phone +46-(0)8-563 051 00 • Fax +46-(0)8-563 051 99 • E-mail: navigation@consilium.se

Text for back of binder:

çConsilium SAL R1a Log System Manual, Doc Id 703810C1 Consilium Marine & Safety AB çConsilium SAL R1a Manual Art No. 703810

Doc ID: 703821B7, SAL R1a Section A General.doc 4 (17)

1 INTRODUCTION

This General section A: of the manual is grouped in the following manner:

• the Table of Contents

• this Introduction including general Warnings to be followed while working with the SAL R1a

• general Shipping and Storing recommendations which are conditions of warranty

• the SAL R1a Technical Specification to be used as a fact and reference chapter and

• the Basic System Information which we highly recommend to read before starting any work with the SAL R1a speed log

Doc ID:703826A3, SAL R1a Section D Accessories.doc 5 (25)

1 SDP, AC/DC POWER SUPPLY FOR SD DISPLAYS

Part number: 701219

Mechanical specification Height: 45 mm Width: 115 mm Depth: 108 mm Weight: 0.5 kg

Electrical specification Input voltage: 48/115/230 VAC Current capacity (max. load): 230 VAC, 2 pcs SD4

48 or 115 VAC, 1 pc SD4 Output voltage: Approx. 18 VDC

Environmental specification Enclosure material: Aluminium Enclosure protection: IP20, protected (indoor environment) Colour: Black Recommended operating temperature:

0° to +40°C

Operating humidity: Less than 93 % RH (non condensing) at 40°C

If the SD4 displays are not powered from the R1a ELC or (optionally LPU2), they can be powered from a local DC-power source on the bridge or by an SDP.

The SDP can power two SD displays in 230 VAC mode, but only one in 115 or 48 VAC modes.

Doc ID:703826A3, SAL R1a Section D Accessories.doc 6 (25)

Dimension drawings for the SDP can be found in the Appendix section.

Doc ID:703826A3, SAL R1a Section D Accessories.doc 7 (25)

2 SD4 BMB, BULKHEAD MOUNTING BOX

Part number: 704080

Mechanical specification Height: 144 mm Width: 144 mm Depth: 54 mm Weight: 0.9kg

Enclosure protection: IP66, exposed Colour: Black

An SD4 display can be mounted directly on an indoor or outdoor bulkhead by using a BMB (Bulkhead Mounting Box). Using supplied screws, nylon washers and properly tighten the cable gland will make the assembly watertight.

M5x30(x4)

M5(x4)

Ø6,6mm

Doc ID:703826A3, SAL R1a Section D Accessories.doc 8 (25)

3 SD4SA, STAND ALONE MOUNTING BOX

Part number: 704090

Mechanical specification Height: 171 mm Width: 200 mm Depth: 67 mm Weight: 1.2 kg

Enclosure protection: IP66, exposed Colour: Black

40 60

Ø5.5(x4)

Doc ID:703826A3, SAL R1a Section D Accessories.doc 9 (25)

4 SD4EB, EXTENSION BOARD

Part number: 704110

Mechanical specification Height: 30.5 mm Width: 66.0 mm Depth when mounted on SD4: Adds 14 mm (Total when mounted 49 mm) Weight: 0.03 kg

Relay outputs: 2 potential free NO contacts Max load: 30 V/30 mA or 15 V/100 mA for each out-put

Enclosure protection: IP66 when mounted in BMB or SA Operating temperature: 0°C to +40° C

The SD4EB is equipped with two relays, which can be used to obtain 200 p/NM speed pulses or for other users in a specific installation.

Refer to SD4 menu LP6 to verify/initiate desired function of the output, see Section C Installation under headlines “Menu Mode” and “Menu function summary” as described for SD4-3.

Installation The SD4EB is installed directly on the back of the SD4 display. Unplug the 10-pole connector from the SD4, plug in the SD4EB (P01) replacing the 10-pole connector and instead plug in the 10-pole connector in the mating connector on top of the SD4EB. The two relay contacts can now be utilised via terminals #1-4 on the SD4EB.

SD4EB Note Terminal 1 Terminal 2

Relay 1 normally open

Terminal 3 Terminal 4

Relay 2 normally open

Doc ID: 703821B7, SAL R1a Section A General.doc 5 (17)

1.1 Warnings

Lethal Warning!

Voltages within this equipment are sufficiently high to endanger life.

Covers are not to be removed, except by persons qualified and authorized to do so, and these persons should always take extreme care once the covers have been removed.

First Aid in Case of Electric Shock

1. Lay victim on his back.

2. Clear victim’s mouth and throat

3. Tilt victim’s head back as far as possible and raise his head

4. Pinch victim’s nostrils

5. Take a deep breath

6. Cover the victim’s mouth with yours and blow, watching his chest rise.

Note: Blow forcefully into adults, but gently into children.

7. Move your face away to allow victim to breathe out, watching his chest fall.

8. Repeat first five to ten breaths at rapid rate; thereafter, take one breath every three to five seconds.

9. Keep victim’s head back as far as possible at all times.

Have someone else send for a doctor. Keep patient warm and loosen his clothing

Do not give liquids until the patient is conscious

Doc ID: 703821B7, SAL R1a Section A General.doc 6 (17)

1.2 Handling

1.2.1 Shipping

Following general rules apply:

• Inspection for damage during transport

• When the unit(s) arrives at destination, inspection should be performed immediately to register any damage that may have occurred during transfer

• The customer is normally responsible for insurance during the transportation. If any damage is found, both the insurance company and the shipping agent must be informed immediately

• The content of the goods shall also be compared with the Packing List. Complain regarding the shipped content must be sent to Consilium Marine & Safety AB within seven days from goods arrival to the addressee.

1.2.2 Storage

After the material, contained in the boxes, has been inspected in the presence of customer and it has been verified that no damage has occurred, the unit shall be stored in its original packing until the time of installation. The storage premises must be dry and well protected.

If the electronic units must be kept in storage for more than one month, it is advisable to insert hygroscope substances, such as silicon gel salts, in the crates.

1.2.3 Handling

The electrical part should be kept in their packing as long as possible and shall be unpacked at the place of installation.

The bottom unit shall be unpacked and mounted at the place of installation. It should not be transported assembled.

The TRU and the TRU cable must be handled with care. Except for when necessary for mounting the cable, the protecting cover over the TRU and TRU cable termination end must not be taken off until just before installation. Under no circumstances, do not cut or alter the length of cable!

Doc ID: 703821B7, SAL R1a Section A General.doc 7 (17)

2 TECHNICAL SPECIFICATIONS

SAL R1a System performance data

Working principle: Acoustic correlation Operating frequencies: 3.8 MHz and 4.2 MHz or 4MHz, software controlled Measuring distance: 130 mm from the surface of the transducer.

Speed Range: +/- 50 knots sensed speed Speed Accuracy: Better than 1% or 0.1 knots relative to sensed water flow whichever is the greatest Distance Accuracy: Better than 1%

2.1 Basic System

2.1.1 Electronics Cabinet (ELC)

Water Track Unit (WTU)

Part number 703800 Mechanical specification Enclosure material: Steel plate Height: 360 mm (reserve space for cable entry at bottom) Width: 360 mm Depth: 170 mm Weight: 10.0 kg Enclosure protection: IP66 Colour: RAL 7035

Electrical specification:

Input voltage: 110–115 VAC / 220–230 VAC +/-10% 50-60

Hz Power consumption: 30 VA nominal Optional power supply: 12 VDC (no protection for reversed polarity) SD4-display power output: 24 VDC to power up to 4 SD-displays (load <

1,2A) Main Speed output: IEC61162-1 / NMEA0183. Serial driver RS

422/485; max load 100 ohm (10 SD4-displays) Analogue Speed output: 0.1 V/knots (load max 5 mA) Relay outputs: 2 x 200 p/NM contact closure, (30V/30mA or

15V/100mA recommended max load) Alarm relay outputs: Switching relay, default setting: power failure

(30V/2A recommended max load) Serial input: IEC61162-1 / NMEA0183 (used for remote user interface)

Doc ID: 703821B7, SAL R1a Section A General.doc 8 (17)

Service connection: 9-pole female D-sub serial data connector (RS 232, for additional PC based user interface and software upgrade)

Enclosure protection: IP66 Environmental: IEC 60945, protected class Heat dissipation (max) = Power consumption Recommended operating temperature:

0°C to +40° C

Extreme operating humidity: Less than 93 % RH (non condensing) at 40°C

2.1.2 SD4-3, One axis STW and distance display

Part number: 704043 Mechanical specification Height: 144 mm Width: 144mm Depth: 16 mm Weight: 0.6 kg

Input voltage: 10-32 VDC (12 or 24 VDC nominal) Current: Maximum 200 mA at 15VDC Serial input: IEC 61162-1 / NMEA0183 Remote inputs: 3 inputs with internal pull-up to +5V, activated by grounding to 0 V Serial output: IEC61162-1 / NMEA0183. Serial driver RS

422/485; max load 100 ohm (10 SD4-displays) SW controlled DC (pulse) output +5 V with 35 mA current capacity

Enclosure material: House, aluminium, front polyester foil Enclosure protection: IP66 in SD4-BMB box or panel mounted on a flat surface Environmental: IEC 60945, exposed class Heat dissipation (max) = Power consumption Colour: House, black

Front, background: Satin black (NCS 9000-N) Operating temperature: -25°C to +55° C

2.1.3 TRU R1, Transducer

Part number: 705050 (30 metre cable) Part number: 705051 (40 metre cable) Mechanical specification Height (excl. cable): 160 mm

Doc ID: 703821B7, SAL R1a Section A General.doc 9 (17)

Diameter: 31.75 mm Cable length standard: 30 m Cable length optional: 40 m Material: Polyurethane and brass

Acoustic frequency: ~ 4 MHz

Environmental:

IEC 60945, submerged class

2.1.4 Mounting Set Single Bottom Sea Valve (MSSBSV)

Part number: 71-21540-00 Mechanical specification Height: 480 mm Diameter, hull bottom flange: 168 mm Minimum headroom to change

TRU:

840 mm

Environmental specification Sea-valve Material Cast Bronze (CuSn5Zn5Pb5) Hydrostatically test pressure 24 bar

Environmental specification Flange Material Bottom flange SS 2142/2172 (alternative S355JR, St52.3N)

2.2 Alternative bottom parts

2.2.1 Mounting Set Double Bottom Sea Valve (MSDBSV)

Part number: 71-21560-00 Mechanical specification Height: Maximum 680 mm above tank top

Diameter, hull bottom flange: 168 mm Minimum headroom to change

TRU:

Depending on double hull distance Minimum height 1500mm + height between double bottom hulls.

Environmental specification Sea-valve Material Cast Bronze (CuSn5Zn5Pb5) Hydrostatically test pressure 24 bar

Environmental specification Flange Material Bottom flange SS 2142/2172 (alternative S355JR, St52.3N)

Doc ID: 703821B7, SAL R1a Section A General.doc 10 (17)

2.2.2 Mounting Set Single Bottom (MSSB)

Part number: 71-21520-01 Mechanical specification Height: 210 mm Diameter: 170 mm Minimum height to change TRU: 480 mm

Material TRU bracket Brass Material Bottom flange SS 2142/2172 ( S355JR, St52.3N)

Doc ID: 703821B7, SAL R1a Section A General.doc 11 (17)

2.2.3 Optional Accessories

For detailed information see Manual Section D

LPU2, Log Processing Unit 2nd generation Part number 704500 Described in Section D Accessories

1to4 NMEA Splitter / Buffer Part Number 704160

N2P, NMEA Pulse Converter Part Number 704161

SD4-4, General display Part number: 704044

SIA-2-8, Analogue Speed Indicator Part number 71-21049-17

SDP, AC/DC power supply for SD4 displays Part number 701219

SD4 BMB, Bulkhead mounting box Part number: 704080

SD4SA, Stand Alone mounting box Part number: 704090

SD4EB, Extension board Part number: 704110

SD4ED, External Dimmer Part number: 704120

SDR2, Remote control Part number: 704130

Doc ID: 703821B7, SAL R1a Section A General.doc 12 (17)

3 BASIC SYSTEM INFORMATION

SAL R1a is an electronic Speed and Distance Measuring Device, i.e. a speed-log, designed for measuring longitudinal speed and distance through water on ships of all kinds and sizes. The speed-log works in principle like two small, synchronized echo sounders built together, comparing echoes from water particles close to the hull. The measuring is based on the so-called Correlation Principle (described below), which entails that it is very dependable and reliable in all kinds of waters. The SAL R1a has no moving parts and no parts sticking out below the hull of the ship.

3.1 Parts

The basic concept of a SAL R1a includes following parts:

1. The Bottom Part comprising the Mounting Set Single Bottom Sea Valve (MSSBSV) and the Transducer Unit (TRU).

The MSSBSV is a watertight holder for the TRU through the ship’s hull, which also makes it possible to inspect and change the TRU without dry-docking.

The Transducer Unit (TRU) contains the two transmitting/receiving elements (crystals) and is connected to the Electronic unit (ELC) by a cable of fixed length of 30 metre.

2. The Electronic Cabinet (ELC) The ELC contains the electronic calculating units, also called the Water Track Unit (WTU) and the Power Supply Unit (PSU). The ELC is normally placed close to (less than 30 cable meters) from the Bottom Part. Up to 10 speed data receivers can be connected directly to the ELC.

3. The SD4- display One STW (WT speed) and distance display (Speed Log Master Display) of SD4-3 type is normally placed on the ship’s bridge. Besides digital displaying of speed and distance through water the SD4-3 is also used as a remote interface unit to the WTU in the ELC.

Following additional and/or alternative units to the SAL R1a concept are optionally obtainable:

1. Alternative Bottom Parts For ships where the bottom part must be installed through a double bottom a Mounting Set Double Bottom Sea Valve (MSDBSV) is needed For smaller ships or for very narrow installation the Mounting Set Single bottom (MSSB), without a sea valve, is an alternative to the MSSBSV.

Note: Dry-docking needed when change or inspection of the TRU..

2. Alternative Transducer cable length TRU with 40 m fixed length. Never cut or alter the cable!

3. Repeater displays Additional SD4 displays can be installed on the bridge, bridge wings, engine control room, as appropriate.

Doc ID: 703821B7, SAL R1a Section A General.doc 13 (17)

Analogue speed indicator SIA2-8. A pointer on a circular scale presents the speed.

Extension box When the ELC is installed far away from the bridge, e.g. the forepeak, and/or when more than 10 repeaters and other speed data receivers are needed, it is recommended to install a NMEA 1to4 Buffer, and or a NMEA N2P Converter unit. Those can be located on or near to the bridge. Only one cable is then needed from ELC to the NMEA Units. See Technical Specification and NMEA Units Installation Guide for further information.

Typical installation basic design

Doc ID: 703821B7, SAL R1a Section A General.doc 14 (17)

Typical installation – extended design

Typical installations – extended design with NMEA 1to4 Buffer, NMEA N2P Converter (Optionally an LPU2 Log Processing Unit can be used as distribution device.)

Doc ID: 703821B7, SAL R1a Section A General.doc 15 (17)

3.2 Functional description

The Transducer Unit (TRU) sends simultaneously two short, parallel sound pulses into the water from two fore and aft oriented crystals. The direction of the pulses is perpendicular to the ships hull. After each transmission, (see fig1) the TRU first waits (echo time) and then receives the echoes from its own transmissions (integration time). This time cycle and the power of the pulses are adapted to reflection from particles in a small volume of water approx. 130 mm from each crystal.

S1 S2

Water flow direction

HullHull

1/2 echo time

Integration time

Fig 1.

So each short pulse creates an echo, or rather a reflected sound-energy, which is unique for each reflected volume of water. That very volume of water will therefore reflect the same energy, if hit again by a new pulse from the other crystal. The change of energy of the echoes, received during a fixed time, creates two more or less similar curve-patterns from the two crystals, but separated in time.

(t0)

S1

S2

Using Correlation technique the time delay (t0) between these two similar patterns can be calculated. The time delay corresponds to the time the ship has used to move the

Doc ID: 703821B7, SAL R1a Section A General.doc 16 (17) distance between the two crystals. That distance is known and the ship’s speed can easily be calculated.

3.3 Boundary Layer

The water close to the ship is dragged by the hull surface when the ship moves through the water. This layer of water with a lower relative speed is called the boundary layer. The thickness of the boundary layer will change due to surface and shape of the hull, speed and trim of the ship and depth of the water. Like all water related speed-logs SAL R1a measures the speed close to the hull. Therefore it may measure a too low speed. Calibrating each individual speed-log in all appropriate speeds must be done to compensate this physical effect. The SAL R1a can also be calibrated for different loads and ballasts of the ship.

3.4 Adverse conditions

It is important to remember that what the R1a measures is actually the speed of a discrete number of reflectors moving in a small water volume under the hull. In order to interpret the echoed signal it is anticipated that the particles are moving parallel to the vessel axis. If the transducer has been installed at a non-preference location of the hull the water flow might be turbulent at the site of the transducer. Under these conditions there is no guarantee for the log to work. See section on installation of bottom parts for correct transducer installation.

In the low speed range, (+/-2 knot) the distance travelled per time interval is low yielding limited information to the correlation function. This influences accuracy and may impose lost speed track conditions.

The log may encounter problems to measure when the ship moves in water with high particle content. This depends on that many particles give "foggy" reflections, which makes it difficult to see the same pattern at the true delay.

3.5 Operation modes

At power on the WTU runs a self-test program. If correct it starts to execute in normal operation.

Five green LED’s on the WTU (on the ELC front panel of SAL R1a) gives status information of

• 12VDC

• Correlation quality

• Measuring mode (clear water-ON, dirty water-OFF)

• Transmission to the two crystals in the TRU

The SAL R1a has three processes running in parallel:

• Measurement process

• Menu system process

• Evaluation (of measurement data) process.

During the measurement process the WTU first works in:

• Seek Zero speed mode (SZ)

• Seek Low speed mode (SL) for speeds below 4 knots

• Seek High speed mode (SH) for speed above 2 knots

Doc ID: 703821B7, SAL R1a Section A General.doc 17 (17)

The seek modes are repeated until a valid speed is found. Then the WTU enters either:

• Locked Low speed mode (LL) for speeds below 2,5 knots or

• Locked High speed mode (LH) for speeds above 2 knots

Then evaluation process calculates the speed and distance continuously and transforms it to different kinds of transmitted speed and distance data as described below.

It is possible to enter the menu system (normally by a SD4-display) without stopping the log from measuring. The different operating modes can be followed and speed calibration can be performed in same menu system. Furthermore TRU tests and simulated speed can be performed. For further information of the menu system See 4 User Guide, Setting/Calibration for detailed instruction.

3.6 Data transmission / reception

Speed and distance data are sent from the Water Track Unit (WTU) as serial IEC 61162-1(NMEA)-messages on standard RS 485 output. Up to 10 NMEA receiving units, e.g. SD4-3, radars, gyros etc, can be connected. Four SD4- displays can be powered directly from the ELC.

IEC61162 (NMEA)-messages are also available through RS232 for data logging, software updates and other remote interfacing by PC.

Speed information is also presented as 200p/NM (two contact closure relays) and one 0,1 v/knots analogue output.

There is also one power failure alarm relay output.

SAL R1a Manual Art No. 703810

Phone +46-(0)8-563 051 00 • Fax +46-(0)8-563 051 99 • E-mail: navigation@consilium.se

SAL R1a Section B

User Manual

Doc ID 703822A6 é C o n s il iu m

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 2 (21)

Revision:

Date Version Author Comment 2005-10-07 A0 HW Created, extracted from 703821B3 2006-11-17 A1 OM Update to fit software D3, corrections in DIP switches 2007-06-07 A2 HW LPU added as optional distribution device, V-menus added 2009-02-05 A3 RB Menus corresponds to sw 700210E1 + editorial 2009-09-14 A4 OM Change WTL to WT 2010-01-04 A5 HW/OM LPU2, NMEA 1to4 Buffer, NMEA N2P

Converter added and LPU and LDU removed as optional distribution device. Corr, 2010-04-16 A6 OM Corrected timeout to 180sec

TABLE OF CONTENT

Table of content Section B: USER MANUAL 1 User Guide

1.1 General

1.2 Daily use of SAL R1a

1.3 Menu Mode

1.4 SD4-3 in Menu Mode

1.5 Write and read only access

1.6 Menu functions

1.7 Serial Remote Dimming functions

1.8 Normal operation read-outs

1.9 Calibrations

1.10 Averaging Speed Constants

1.11 Software revisions

2 Setting Up Guide 3 Trouble Shooting

3.1 Conceivable faults and actions

3.2 Test methods

3.3 DIP switches and jumper settings

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 3 (21)

SECTION B: USER MANUAL

1 USER GUIDE

1.1 General

The SAL R1a is normally conducted from the SD4-3 display on the bridge. If more than one SD4-3 is installed, one of them shall be designated as the Speed Log Master Display, which means that it is the remote display for the WTU menu in the SAL R1a speed log.

This SD4-3 is labelled “Master”. Same SD4-3 display or another SD4-3 display can also remotely control other slave SD4 displays e.g. dimming function (See 3 Basic System Information).

The ELC (Electronics Cabinet), which due to the TRU-cable length is mounted in the vicinity of the Bottom Parts, has fuses and control lamps (LEDs), which can be checked if a system failure occurs. (See 6 Trouble Shooting Guide)

U/N 704043

Mode Trip /

DIST

Reset Trip - +

Esc Menu Enter

STW kn

SAL

SD4-3

TestPress 2 sec

DIM

Mode é Consilium

Serial Digital Display SD4-3 for STW (WT) indication

1.2 Daily use of SAL R1a

The SD4-3 display is configured especially for the water tracking speed log SAL R1a.

The display has an upper window STW (WT) Speed, showing the longitudinal speed through water, STW, ahead or astern. The up pointing arrow is lit when the speed is ahead and the down pointing arrow is lit when the speed is astern.

The lower Mode window shows as default the distance the ship has sailed, in nautical miles, either totally STW (WT) TOTAL, or since latest reset of the trip counter STW (WT) TRIP. Distance made astern is not added to these counters as default.

The indication LED positioned over the Mode button is reserved for future use.

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 4 (21)

Use the Trip/DIST button to toggle the Mode window between showing Trip distance and Total distance.

Use the Reset Trip button to zero the trip counter by pressing more than 2 sec.

To adjust the display brightness, use plus (+) button to increase and minus (-) button to decrease. Both buttons pressed simultaneously presents a complete display lamp test.

1.3 Menu Mode

The Mode window of the SD4-3 Display can also be set to Menu Mode. The Menu Mode is used for internal settings of the display and when SD4-3 is used as a remote display for other units e.g. the R1a/ WTU menu structure or for remotely dimming of other SD-displays.

The Menu Mode is reached by pressing the Mode button for min. 5 sec. The Mode Window will show the text “PRESS ENTER FOR MENU”. Then press the “Enter button” (Reset Trip) within 5 seconds.

The Mode Window will now show the current menu and the upper window will maintain the speed presentation sent out from the WTU.

The six buttons under the Mode Window have now changed to have alternative functions.

Alternative functions are lit in red text below relevant button.

From left to right the bottoms now have the following functions

Mode: “Mode button”. Will inform what remote device that is connected.

Esc: “Blank button”. When in “Remote Device menu” the Esc function is used to leave the “Remote Device menu” (E.g. the WTU menu). When not in “Remote Device menu” the Esc button has the same function as Menu button and Enter buttons pressed simultaneously, (see Menu-button below)

Menu: “Total/DIST button”. Is used alone, or together with the Minus (-) button, or together with the Enter button, to move in the menus as described below.

Menu button alone, will display next menu i.e. step forward on same menu level.

Menu button and Minus (-) buttons pressed simultaneously will display previous menu, i.e. step back on same menu level.

Menu button and Enter buttons pressed simultaneously will move up one menu level. Except when leaving the “Remote Device menu”. (see Esc-button)

Enter: “Reset Trip button” is used to store changed values or to move to sub-menus.

- + “Minus button” and “Plus button” are used to change status (E.g. write access

OFF/ON) and /or to change device values.

Note: When being in the Menu System and no button is pressed for 3 minutes, the Mode window will return to previous information displayed before the Menu System was entered.

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 5 (21)

1.4 SD4-3 in Menu Mode

The Menu Mode has three “Local Menus” and one “Remote Device menu” on the first set-up level:

• SD4-3 LOCAL. This is the start menu when entering the Menu Mode. If one or more other displays are remotely dimmed from the display, this menu shows a second text line and can easily be used to turn the remote dimming function

ON/OFF.

• LP0 PROPERTIES. This menu contains sub menus for local setting up of the display. Warning: Do not turn write access ON without special training.

• LS0 REMOTE SETUP. This menu contains sub menus for setting up when the display is used as a Speed log Master Display /Remote Device for other units and displays.

Warning: Do not turn write access ON without special training

• R0 REMOTE DEV. On a designated Speed Log Master Display this menu provides access to a remote device, e.g. SAL R1a/ WTU menu structure.

Note! Verify the setting in menu LS7.

1.5 Write and read only access

Default for sub menus when entering the menu system is reading access only, e.g. the Mode window shows WRITE ACCESS OFF.

When changing the write access to ON (“Plus button” confirmed by “Enter”), then sub menus are accessible for changes. Be careful to change intended parameters only. When leaving sub menus the write access is automatically set to OFF.

1.6 Menu functions

The complete list for fast indexing of the Menu System, available for the daily user, is included in Section C Installation under headline “Menu function summary” for SD4 displays and for SAL R1a /WTU under headline “2. Setting up Guide”.

A Menu Structure chart for the SD4-3/WTU is found under Section E Appendix.

Parameters, which can be changed during the operation of the SAL R1a speed log, are described here below.

Special menus for testing can be found under Trouble shooting.

1.7 Serial Remote Dimming functions

When serial remote dimming function is installed and initiated, each SD4 display can be dimmed individually, but it is also possible to dim four different displays remotely from one display. This remote dimming function can be turned on/off in the first menu when entering the Menu mode.

Phone +46-(0)8-563 051 00 • Fax +46-(0)8-563 051 99 • E-mail: navigation@consilium.se

Manual

SAL R1a Speed log

Document Id. 703810C1

C o n s il

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 6 (21)

Set-up of the Remote Dimming function is described in the Installation Guide.

If separate external dimming buttons have been connected they are working in parallel with those of the display they are connected to.

1.8 Normal operation read-outs

The SAL R1a in normal operation calculates the speed from the sensor signals (see Basic System Information). It is possible to follow how the WTU is working by going in-to the R0 REMOTE DEV menu. Then go down one menu level (Enter) and wait for the display to synchronise with the remote device(s). Choose R1a / WTU (Enter) and the Normal operation menu will be displayed. It uses following field descriptors, which are described in the table below. If no speed is found the log enters search mode where ±XX.XX and S=DDD share the same position.

Descriptor Explanation MM Working mode

SZ= Seek Zero speed SL= Seek Low speed LL=Locked Low speed SH=Seek High speed LH=Locked High speed

H Hardware mode C = Clear water D = Dirty water Q = Extra dirty water

±XX.XX Sensed (raw) speed from transducer ±YY.YY / --.-- Output speed including calibration and time constant averaging.

Field is --.—if no valid speed is available.

F Digital Filter setting. 'F' equals digital filter pre-processing of sample data, 'R' equals raw sampling, 'L' equals limiter + digital filter.

C=DDD Correlation coefficient between 0 and 999, higher coefficient is better S=DDD Signal quality value between 0 and 999, higher value is better ZZZZ:TTTT first/second channel AGC level [mV] UUuu-VVvv first/second channel AD Convert levels [bits], SD4-3 LOCAL

REMOTE DIM [OFF]

MMH ±XX.XX±YY.YY

FC=DDD ZZZZ:TTTT

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 7 (21)

The working modes (MM) are:

Seek zero speed mode

In "Seek-zero-Speed-mode" the log calculates a special correlation function to estimate the speed range and detect zero speed condition.

During zero speed search the following display information is shown;

If zero speed is detected (locked) the following display information is shown:

Seek low speed mode

In "Seek-low-speed-mode" the log seeks for speed in the lower speed range. It calculates the correlation function corresponding to a number of discrete speeds. The values for correlation coefficient (C) and signal quality (S) are presented:

Locked low speed mode

In "Locked-Low-Speed-mode" the log calculates the correlation function corresponding to a number of discrete speeds. Interpolation is used to give better speed resolution. The display presents speed information in the following format:

Seek high speed mode

In "Seek-high-speed-mode" the log searches for speed in the higher speed range. It calculates the correlation function corresponding to a number of discrete speeds. The values for correlation coefficient (C) and signal quality (S) is presented:

SZC 00.00 ±00.00

FC=DDD ZZZZ:TTTT

SLC S=DDD ±YY.YY

FC=DDD ZZZZ:TTTT

LLC ±XX.XX ±YY.YY

FC=DDD ZZZZ:TTTT

LZC 00.00 ±YY.YY

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 8 (21)

Locked high speed mode

In "locked-high-speed-mode" the log has locked in on the speed and uses a feedback algorithm to adjust sampling to track the speed. The speed is then presented in the following format:

Leave the WTU menu and the Menu mode and return to the normal Trip/Total mode by pressing ESC three times.

1.9 Calibrations

The SAL R1a has two different methods for calibrating the speed.

The SAL R1a also has a function for compensating small differences in characteristics of individual transducers. This TRU calibration is a fixed compensation factor, TC. The TC factor is marked on the transducer body and on the transducer cable termination end. This factor has to be set at commissioning and before any calibration methods are chosen.

If changing the transducer this factor has to be set according to the TC factor of the new transducer.

• Draught calibration – a single point calibration factor compensating differences in indicated speed, due to load and trim of the ship. Three different preset draught conditions can be programmed. They are named: FULL LOAD, BALLAST 1 and

BALLAST 2.

• Speed depending calibration - multiple point calibration factors compensating differences in indicated speed over the whole speed range. Factors can be preset for up to ten different speeds. Speeds between the calibrated points are interpolated automatically.

Note: The minimum necessary calibrations to be set are the TRU-calibration plus at least one of the draught calibrations. If so, after setting the TRU-calibration, choose e.g. FULL LOAD and compensate for the normal cruising speed used at normal load conditions (se below)

Draught Calibration and Speed Depending Calibration shall normally not be used at the same time.

1.9.1 TRU Calibration

This type of calibration is compensating small differences in characteristics of individual transducers. The transducer has been independently calibrated in factory and its compensator factor must be programmed into the speed log it is connected to. The factor is engraved on the transducer housing as TC±XXX. It is also labelled at the termination

SHC S=DDD ±YY.YY

FC=DDD ZZZZ:TTTT

LHC ±XX.XX ±YY.YY

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 9 (21) end of the TRU-cable core No. 1. Example: TC+123 means calibration factor +1,23% and TC-101 means calibration factor –1,01%.

Note: The TC value shall be set before any other calibration is performed.

Procedure:

Go in to the Menu mode; step to R0 REMOTE DEV and then down to R1a/WTU sub menu C0. Choose WRITE ACCESS ON (+) and proceed down to menu C4.

Change the value by using the +/- buttons and then save the value by pressing Enter.

To leave this menu, press Menu and Enter simultaneously two times.

1.9.2 Draught calibration (Single point calibration)

This type of calibration is meant for merchant vessels where the water flow around the hull is changing due to different draughts and trims. Three calibrations can be performed for cruising speeds relevant to each of three decided draught/load conditions (FULL LOAD or BALLAST 1 or BALLAST 2). These calibrations are compensating with the same calibration percentage, respectively, over the whole speed register.

Changing between the three draught/load calibration types can then be done later in menu C1 by pressing plus (+) or minus (-) without changing the write access in menu C0.

However the change must be saved by pressing the ENTER button.

Before the calibration runs, make sure:

• that correct TC factor is set (see above)

• that the desired draught condition is chosen and set to 0% (Menus C1 /C2)

• the Multi Point Calibration is DISABLED (Menu C3)

The system is calibrated by sailing a true, known distance in calm waters. To eliminate variations caused by tide, current and wind, the ship should run the same route in both directions. For each separate run, carefully observe beginning and end of the true sailed distance and corresponding measured distance on log display. Then, for each speed, do following calculation to find the calibration factor CF:

CF=[(expected dist.1 + expected dist.2 ) / (measured dist.1 + measured dist.2)]

Normally the true distance is based on optical observations, but it is also possible to use other reference systems like DGPS or similar. If the calibration factor is based on a very long (several hours or days) comparison with GPS observations, make sure that it has not been affected by wind and current.

C4 TRU CALIBRAT.

MARKING: TC±000

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 10 (21)

Use the menu system to enter the calibration factor in menu C2. Note that the calibration factor shall be expressed in percentage. A calculated value of e.g. 1.234 shall be entered as 23.40%.

Procedure: (see above for how to move in the menu system)

1. Go in to the Menu System, step to R0 REMOTE DEV and press Enter.

2. Go to R1a/WTU sub menu C0

3. Choose WRITE ACCESS ON (+)

4. Move down to menu C1 and check that desired alternative is chosen (see above)

5. Move to C2 and press Enter

6. Use + and – to change to calculated value from the calibration runs (e.g. 23.40%)

7. Save by pressing enter

8. To leave this menu, press Menu and Enter simultaneously two times.

9. Leave the WTU menu and the Menu mode and return to the normal Trip/Total mode by pressing ESC three times

Repeat the procedure (2-6) for each draught condition if desired.

1.9.3 Speed Depending Calibration (Multiple Point Calibration) This type of calibration is meant for vessels needing varying speed compensation in the whole speed register. Up to ten different speeds can be calibrated for, spread to speeds both ahead and astern. Speeds between the calibration points are interpolated automatically, except the area nearest zero, which uses its nearest calibration factor down

(up) to speed zero.

The Multiple Point Calibration can be ENABLED and DISABLED in menu C3 without changing the write access rights in Menu C0. However the change must be stored by pressing the ENTER button.

Make the calibration runs and calculations as described above for Single Point Calibration, but now repeat the procedure for each speed desired.

Before the calibration runs, make sure

• that correct TC factor is set (see above)

• that the chosen draught condition (e.g. BALLAST 1) is set to 0% (Menus C1 and

C2)

• that the Multi Point Calibration is DISABLED (Menu C3)

C0 CALIBRATION

WRITE ACCESS OFF

C1 DRAUGHT COND

FULL LOAD 0,00%

C2 DRAUGHT CAL

FULL LOAD +23,40%

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 11 (21)

Due to the interpolation between the compensation factors the Multi Point Calibration must be DISABLED during all calibration runs, also when making a later run for an extra calibration point.

Procedure to set new multiple points: (see above for how to move in the menu system)

4. Move to menu C3 and change to ENABLED (+)

5. Move down (with Enter) to C3.01.

(if no values are set, and e.g.:)

(if values are set before)

6. If needed change to next point by pressing Menu

7. Press Enter

8. Use + and – to set which speed to be calibrated for (expected) at that point (i.e.

the speed used at the calibration run).

9. Save by pressing Enter

10. Use + and – to change the calculated calibration factor for that speed

11. Save by pressing Enter

12. Change to next point by pressing Menu and repeat from 6.

13. To leave this menu, press Menu and Enter simultaneously two times

14. Leave the WTU menu and the Menu mode and return to the normal Trip/Total mode by pressing ESC three times

Repeat the procedure (2-6) for each draught condition if desired.

C0 CALIBRATION

WRITE ACCESS OFF

C3 MULTI-P CAL

ENABLED

C3,01 MULTI-P 1

UNUSED POINT

C3.01 MULTI-P 1

10,0 KN 23,45 %

C3.01 MULTI-P

EXPECTED 0.00 KN

C3.01 MULTI-P 1

10,0 KN 0,00 %

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 12 (21)

Procedure to delete multiple points: (see above for how to move in the menu system)

4. Move to menu C3 and change to DISABLED (-)

5. Move down (with Enter) to C3.01.

6. If needed change to next point by pressing Menu

7. Press Enter

8. Press Enter for deleting point. Averaging speed constants

Note: These settings must not normally be changed. We recommend contacting Consilium Marine & Safety for advices before changing default values.

C0 CALIBRATION

WRITE ACCESS OFF

C3 MULTI-P CAL

DISABLED

C3,01 MULTI-P 1

DELETE POINT

C3.01 MULTI-P 1

10,0 KN 23,45 %

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 13 (21)

Procedure to delete all calibrations values This menu is used to reset all calibration values to factory default.

The following menu is presented when write access is off and no reset is possible to perform:

The following menu is presented when write access is on.

Press + to enable reset:

Press ENTER to activate reset. All calibration values will be reset to 0.

Note! There is no way to restore old values after reset so write down old values prior to reset.

1.10 Averaging Speed Constants

If the speed is fluctuating in an annoying manner it can be possible to level it out with a filtering time constant. Two different constants can be set, one for the lower speed range, for faster reaction of speed changes, and one fore the higher speed range, normally needing more equalized speeds. The threshold between low and high averaging speed constants can also be set.

Procedure:

1. Go in to the Menu System; step to R0 REMOTE DEV and press Enter.

2. Go to the R1a/WTU sub menu S0.

3. Choose WRITE ACCESS ON (+) and proceed down to menu S1.

4. Change the low time constant and save the value.

5. Proceed to menu S2

S1 AVERAGE LOW

TIME= 6 SECONDS

S2 THRES LOW-HI

THRESHOLD= 3,0 KN

S0 SETTINGS

WRITE ACCESS OFF

C5 Calibrat. RESET

WRITE ACCESS OFF

C5 Calibrat. RESET Disabled

C5 Calibrat. RESET Enabled

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 14 (21)

6. Change the speed threshold and save the value

7. Proceed to menu S3

8. Change the high time constant and save the value

To leave this menu, press Menu and Enter simultaneously two times

1.11 Software revisions

The SD4 display software revision can be found in menu LP9 in the SD4 Menu System, The R1a / WTU software revision can be found in menu M6 in the WTU Menu System.

2 SETTING UP GUIDE

The SAL R1a Setting Up Procedure includes all steps after the Mechanical and Electrical Installations have been performed and up to the calibration of the speed log. (For calibration see User Guide.) The Setting Up Guide is limited to short instructions and we therefore recommend to using it as a check list. For errors or disruptions during the setting up procedure, please refer to Trouble Shooting Guide.

Each electrical installation is instructed to be completed by the Pre Set up Procedure. We recommend to double check these points before supplying power to the unit:

• Remove any possible particles from the cabinet(s)

• Carry out a visual inspection of the installed components and cables referring to the layouts of the unit and to the interconnection drawings

• Check that cable terminations have a firm grip of the cable wires

• Check that cable glands have a firm grip around the cables

• Check that the Transducer cable shield is firmly grounded in the cable gland of the ELC.

• Check for proper cable bends to assure a proper amount of slack

• Check that ground connections are duly tightened.

• Carefully check the main power voltage and the integrity of the fuses

Also check that the transducer is correctly installed down in working position and longitudinally aligned.

Set the SAL R1a Speed log to power.

S3 AVERAGE HIGH

TIME= 2 SECONDS

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 15 (21)

When SAL R1a is set to power the WTU runs a short Self Test Program and then proceeds in normal operation.

After setting the SAL R1a speed log to power, follow the procedure below and act accordingly. If a fault occurs or is detected, use the Trouble Shooting Guide to analyse and eliminate the reason.

• Check that the four LED indicators on the ELC front panel (upper right corner) function normally, i.e. TR1 and TR2 shall be lit showing that the transmitter of the WTU is working. CLEAR WATER and CORR OK may be lit depending on water and speed conditions at present. CLEAR WATER is lit when the signal conditions from the transducer are good or better. CORR OK is lit when the correlation coefficient is good or better.

NOTE: It is normal that the CLEAR WATER and CORR OK LED’s can be off when the ship is in harbour, in dirty and shallow water or when manoeuvring.

• Use the Speed Log Master Display, SD4-3 to communicate with the WTU by going into the R0 REMOTE DEV menu. (see User Guide)

• Check that the WTU is working in a operating mode relevant to present water and speed conditions

• Go to Menu T0

• Change to WRITE ACCESS ON

• Move down to T1 and use default speed 8 knots or use speed as desired

NOTE: Now the SAL R1a will stop measuring ship’s speed and instead it is showing the simulated speed on all users connected.

• Check that all connected users show the same speed

• Change to and check at least two more speeds within the ship’s speed range, including one speed astern (minus)

• Move to TA menu and simulate Log Failure Alarm by pressing -(minus)

• Check that connected alarm is activated (if any)

• Leave the T menu by pressing MENU and ENTER simultaneously two times.

• Check that simulated speed is replaced by actual speed

• Check that TC factor (in Menu C4) is set according to calibration factor as marked on TRU cable core No.1. (See User Guide)

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 16 (21)

• Check that the default settings are in accordance with values noted in the table below (change only if needed):

No Name Default Function

MM (NORMAL

OPERATION)

Timeout to normal operation after 180 seconds. LCD presentation according to chapter "Normal operation".

FE FATAL ERROR Fatal error presented for 2 seconds followed by reset C0 CALIBRATION Selects calibration menus C1 Draught Cond FULLOAD Selects predefined draught condition with predefined calibration factor C2 Draught Cal 0% Sets calibration factor for draught condition C3 MultiPointCal Disabled Select Multiple Point Calibration C4 TRU Calibrat (TC+000) Sets engraved transducer calibration factor C5 TRU Calibrat Disabled Reset calibration values M0 MISCELLANEOUS Selects miscellaneous menus M2 CPU Reset Disable watchdog and timeout to reset M4 Total Distance Adjust total distance counter M5 Trip Distance Reset trip counter M6 SW revision Display the software revision of the application software M7 FW revision Display the PLD firmware revision M8 HW revision Display the PCB hardware revision M9 Access level All Users: Some menus are hidden

Authorised Expert: No menus are hidden or locked S0 SETTINGS Selects Settings menus S1 Average Low 6 Sets averaging time constant in seconds for low speed range S2 Thres Low-Hi 3.0 Speed limit between low and high averaging time constant.

S3 Average High 2 Sets averaging time constant in seconds for high speed range S4 Max Ahead 40 Maximum ahead speed magnitude [kn] S5 Max Astern 10 Maximum astern speed magnitude [kn] S6 Lock Timeout 20 Lock mode timeout when entering search mode [sec] S9 VBW format extended extended with docking log info or short earlier format Sa VHW Telegram Disabled Adds message VHW to NMEA out Sc Analogue Speed Ahead +

Astern

T0 TEST Selects Test menus T1 Simulation 8.00 Put simulated speed as $VDVBW in NMEA output stream and on pulse output T3 TRU Passive Transducer test mode (transmit off) T4 TRU Active Transducer test mode (transmit on) Ta LogFail Alarm Set and clear log fail alarm V0 VIEW Selects View menu to see log statistics since last power up

(Only for service purpose) V1 System Uptime Shows uptime in different modes V2 Speed/no speed measuring time Shows time of successful measuring/failed measuring during speed and zero speed conditions V3 Mode

Transitions Shows number of mode transitions between C-D-Q modes

V4 Mode depend.

correlation

Shows average and maximum correlation in the different modes

V5 Speed depend.

correlation

Shows average and maximum correlation in different speed intervals

• Leave the WTU Menu and the SD4-3 Menu Mode by pressing ESC

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 17 (21)

3 TROUBLE SHOOTING

First part of the Trouble Shooting Guide is built up around conceivable faults and disruptions acquired from experience. It also includes practical suggestions and solutions to solve the listed problems. The second part consists of test methods, referred to in the first part, as help at faultfinding.

Actions for analysing and finding faults needs however knowledge of R1a Speed Log working principles (see Basic System Information) and how to communicate with the WTU menu (see User Guide).

3.1 Conceivable faults and actions

1. R1a indicates wrong speed

2. R1a has locked on constant speed Reason Action

The WTU-program is in test mode.

Enter the WTU-program T-mode and leave that mode by depressing MENU and ENTER simultaneously two times and then ESC ESC.

3. R1a indicates a delayed speed at accelerations and retardation

Too high averaging time constant or wrong speed limit between constants.

Change averaging time constant or speed limit between constants. See User Guide 1.10

4. R1a indicates an oscillating speed around correct value

Too low averaging time constant or wrong speed limit between constants.

Change averaging time constant or speed limit between constants. See User Guide 1.10

The TRU is not aligned longitudinal Check the TRU according to TRU

Physical inspection described below The log is set to wrong speed calibration (WTU-menu C1, C3).

Change calibration alternative. See User Guide 1.9

The log is set to wrong TRU calibration (WTU-menu C4).

Check TRU calibration. See User Guide 1.9

The speed calibration is not relevant to present conditions.

Make a new log calibration. See User Guide 1.10

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 18 (21)

5. Some of connected displays/users do not indicate correct speed or no speed at all Reason Action

At any of reasons below in this table. Change to simulated speed as described below.

Bad contact between ELC / NMEA UNIT(S) (LPU2) and display / user.

Check terminations in ELC / NMEA UNIT(S) (LPU2) and Display / user.

Check cables.

Only serially (NMEA) feed displays not working. Serial output not working in

ELC / NMEA UNIT(S) (LPU2)

Measure serial (NMEA) signal in ELC / NMEA UNIT(S) (LPU2) as described below

6. R1a indicates speed only intermittently and between that, three dashes (---) in

SD4-3 Speed Window Note! SAL R1a is primary a longitudinal speed measuring system, thus this behaviour may be normal due to e.g. sharp manoeuvring..

Reason Action The TRU is not aligned longitudinal or not in working position

Check the TRU according to TRU Physical Inspection described below

The TRU sensor surface is covered by algae

Check the TRU according to TRU sensor surface inspection described below

7. R1a indicates continuously no speed and only three lines (---) in SD4-3 Speed

Window Reason Action

The TRU is not aligned longitudinal or not in working position

Check the TRU according to TRU Physical Inspection described below

The TRU sensor surface is covered by algae

Check the TRU according to TRU sensor surface inspection described below

8. R1a indicates no speed at all and the SD4-3 shows NO NMEA in Mode Window and Err in the Speed Window Reason Action

The speed log has lost power Check that ELC is in operation The log distribution unit has lost power Check that NMEA UNIT(S) (LPU2) is in operation.

The serial connection is broken Check cables.

3.2 Test methods

1. Simulated Speed (refer to: 2 SETTING UP GUIDE).

• Go to WTU test mode and simulate different speeds, e.g. +8 knots and –2 knots.

• Check that all connected displays/users show the simulated speed.

• Leave the test mode by pressing MENU/ENTER simultaneously and then ESC, ESC

• Check that simulated speed is replaced by actual speed

Doc ID: 703822A6, SAL R1a Section B User Manual.doc 19 (21)

2. Reading NMEA messages

• Use a standard…