Birdge_Insp_Rpt_5140-183P.pdf

PDF 3 MB Posted

Attached to
Blue Ridge Parkway - WMS NC (1) Federal contract opportunity
Solicitation number
DTFH71-13-R-00013
Issued by
Department of Transportation Federal Highway Administration

About this file

Bridge Inspection Report - 5140-183P

View the file

Other files for this federal contract opportunity

Other files attached to Blue Ridge Parkway - WMS NC (1), newest first.
File Type Posted
Amendment_002_-_NPS_BLRI_WMS_NC(1).pdf PDF
Amendment_001_-_NPS-BLRI_WMS_NC(1).pdf PDF
ADV_Offeror's_Qualifications_Form.doc DOC document
Birdge_Insp_Rpt_5140-176P.pdf PDF
Birdge_Insp_Rpt_5140-178P.pdf PDF
Birdge_Insp_Rpt_5140-177P.pdf PDF
FP03_Eng_.pdf PDF
Plans_-_PRA-BLRI_WMS_NC(1).pdf PDF
FP03_Errata.pdf PDF
Birdge_Insp_Rpt_5140-179P.pdf PDF
Birdge_Insp_Rpt_5140-182P.pdf PDF
RFP_Solicitation_-_PRA-BLRI_WMS_NC(1).pdf PDF
VETS-100A-Form.pdf PDF
Birdge_Insp_Rpt_5140-181P.pdf PDF
Birdge_Insp_Rpt_5140-099P.pdf PDF
Birdge_Insp_Rpt_5140-180P.pdf PDF
Birdge_Insp_Rpt_5140-091P.pdf PDF
REV_Synopsis_Notice_-_PRA-BLRI_WMS_NC(1).doc DOC document
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BRIDGE INSPECTION REPORT

STACK ROCK CREEK BRIDGE

BLUE RIDGE PARKWAY OVER STACK ROCK CREEK

BLUE RIDGE PARKWAY

LN

STRUCTURE NO. 5140-183P

INSPECTION TYPE: ROUTINE

INSPECTION DATE: 7/27/11

Report prepared by: ED

MILE POINT: 304.63

Federal Highway Administration KILOMETER POINT: 490.03 Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP http://www.efl.fhwa.dot.gov/FLHBO/BIP

STRUCTURE SUMMARY STRUCTURE NO. 5140-183P

STACK ROCK CREEK BRIDGE INSPECTION DATE: 7/27/11

BRIDGE IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ....... STEEL NO. OF MAIN SPANS:

MAIN SPAN TYPE: ............... GIRDER & FLOOR BEAM SYSTEM NO. OF APPR. SPANS:

# OF BEAMS, MAIN SPAN: .. 2 STRUCT. TOTAL LENGTH: .. 284.0 FT (86.6 M)

DECK TYPE: ......................... CONCRETE CAST-IN-PLACE MAX. SPAN LENGTH: .......... 140.0 FT (42.7 M)

WEARING SURFACE: .......... MONOLITHIC CONCRETE DECK WIDTH: ...................... 38.0 FT (11.6 M)

ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH: ..... 34.5 FT (10.5 M)

PIER FOUNDATION(S): ........ OTHER YEAR BUILT:

ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. N/A

PROJ./PLAN REF. NO: ......... 02H3J14 / 2H3JI4 SKEW ANGLE: ..................... 0 °

NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL: ........ YES

STRUCTURE HISTORY: ...... 2008 - APPROACHES REPAVED

LOCATION

BLUE RIDGE PARKWAY MILE POINT: ..................... 304.63 (KM PT 490.03)

STATE: ................................. NORTH CAROLINA LOCATION: 0.51 MILES FROM U.S. ROUTE 221

FACILITY CARRIED: ............ BLUE RIDGE PARKWAY

FEATURE INTERSECTED: .. STACK ROCK CREEK

STRUCTURE EVALUATION SUMMARY

This weathering steel girder bridge is in good condition overall, with only minor problems at this time. Problems include moderate cracking of the pavement at both approaches, a displaced capstone at the southeast parapet end, and a loose rail at the southwest railing end with missing anchor nuts from both rails. Also, the centerline striping over the deck is beginning to fade.

Corrective action should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future.

INSPECTION TEAM: A. IMMEL, W. COLLINS (VOLKERT, INC.)

CONDITION ASSESSMENT:

AARON IMMEL, P.E., FIELD TEAM LEADER

REPORT REVIEW:

MARCUS MILLER, P.E., LEAD STRUCTURAL ENGINEER 703-404-6252

REPORT APPROVAL: DATE: 12/19/11

JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140-183P

A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

D226 PRIORITY OF IMPROVEMENT

ITEM

NO.

MAINTENANCE RECOMMENDATIONS

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT COST

UNIT

ESTIMATE

COST

PRELIM.

222.3 RESET CAPSTONE AT SOUTHEAST PARAPET END. 1 CY

58.6 TIGHTEN LOOSE RAILING. REPLACE MISSING RAIL ANCHOR NUTS ON BOTH

RAILS.

1 LS

PRELIM. MAINTENANCE TOTAL :

ITEM

NO.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST ESTIMATES

PRELIM. COST

REHAB. RECONSTR.

222.4 REPAVE BOTH APPROACHES. 2 EA

58.10 REPAINT CENTERLINE STRIPING ON DECK. 568 LF

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL:

PRELIM. REHABILITATION TOTAL:

PRELIM. RECONSTRUCTION TOTAL: ...

TOTAL ITEMIZED COSTS:

PRELIMINARY ESTIMATE TOTAL* :

(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)

REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.

FIELD INSPECTION REPORT STRUCTURE NO. 5140-183P

CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223

N NOT APPLICABLE

9 EXCELLENT CONDITION

8 VERY GOOD CONDITION - no problems noted.

7 GOOD CONDITION - some minor problems.

6 SATISFACTORY CONDITION - structural elements show some minor deterioration.

5 FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.

4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour.

3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.

Fatigue cracks in steel or shear cracks in concrete may be present.

2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

1 “IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.

0 FAILED CONDITION - out of service; beyond corrective action.

CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

58. DECK 7

1. DECK SLAB G

2. EXPANSION JOINTS G

3. WEARING SURFACE N

4. RIDEABILITY F

5. CURBS, SIDEWALKS, AND MEDIAN G

6. PARAPETS AND/OR RAILINGS F

7. DRAINS AND DRAINAGE G

8. UTILITIES N

9. DEFLECTION AND/OR VIBRATION G

10. OTHER (STRIPING) F

59. SUPERSTRUCTURE 7

1. BEARING DEVICES

2. GIRDERS OR BEAMS

3. ARCH(ES) OR SLAB(S)

4. FLOOR BEAMS AND STRINGERS

5. TRUSSES

6. DIAPHRAGMS AND BRACING

7. PAINT

8. FASCIA(E)

9. DEFLECTION AND/OR VIBRATION

10. ALIGNMENT

11. OTHER

60. SUBSTRUCTURE

ABUTMENTS

1. BREASTWALLS OR COLUMNS

2. PILE BENTS

3. CAPS AND/OR BEARING SEATS

4. BACKWALLS AND/OR BULKHEADS

5. FOUNDATIONS

6. WINGWALLS

7. WEEP HOLES

8. EXPANSION JOINTS

9. EROSION AND/OR SCOUR

10. SETTLEMENT OR DEFLECTION

11. SLOPE PROTECTION

12. OTHER

PIER(S)

13. WALLS AND/OR COLUMNS

14. PILE BENTS

15. CAPS AND/OR BEARING SEATS

16. FOUNDATIONS (ROCK)

17. EROSION AND/OR SCOUR

18. SETTLEMENT OR DEFLECTION

19. OTHER

G G N G N G N N G G N

G N G G N G N G G G N N

G N G N G G N

58.1

58.2

58.4, 222.4,6

58.5

58.6

58.7

58.9, 59.9

58.10

59.1

ITEM REFERENCE AND REMARKS

MINOR ABRASION OF DECK SURFACE. MINOR EFFLORESCENCE ON

UNDERSIDE AT CONSTRUCTION JOINTS. MINOR CRACKING OF

FILLET. MINOR RANDOM CRACKING OF DECK SURFACE. MINOR

CRACKING OF HAUNCH OVER PIER DIAPHRAGM BOX NEAR

CENTERLINE. MINOR CRACKING WITH EFFLORESCENCE ON DECK

OVERHANGS.

MINOR DETERIORATION OF COMPRESSION SEALS AT ABUTMENTS.

MINOR DEBRIS IN EXPANSION JOINTS. SEVERAL NUT CAPS ARE

MISSING.

BOTH APPROACHES HAVE BEEN PATCHED IN 2009. SETTLEMENT AT

BOTH APPROACHES IS APPROXIMATELY 5/8".

MINOR SCALING AND HONEYCOMBING OF CONCRETE.

SOUTHWEST RAIL END IS LOOSE. SOUTH END RAIL CAP MISSING

ON EAST RAIL, HOWEVER END HAS NOW BEEN FILLED WITH

CONCRETE. COLLISION DAMAGE TO WEST RAIL, 20' FROM SOUTH

ABUTMENT. TOTAL OF SIX RAIL NUTS MISSING FROM WEST RAIL

AND ONE NUT MISSING FROM EAST RAIL. WIDESPREAD RUSTING

OF ANCHOR BOLTS AND NUTS AT POST AND RAIL CONNECTION.

DAMAGED GRATE AT NORTHEAST APPROACH.

MINOR VIBRATION UNDER VEHICULAR LOADS.

CENTERLINE STRIPING BEGINNING TO FADE.

NEOPRENE BEARING PAD AT SOUTHEAST CORNER IS

HORIZONTALLY DEFLECTED TO NORTH; 1-1/8" OVER 6" HEIGHT.

INSPECTION DATE: 7/27/11

STRUCTURE NO. 5140-183P FIELD INSPECTION REPORT

STACK ROCK CREEK BRIDGE

ITEM REFERENCE AND REMARKS

AVERAGE CLEAR OPENING 8.

NORMAL VELOCITY 7.

ADEQUACY OF OPENING 6.

OTHER 5.

WATERWAY OBSTRUCTIONS 4.

CHANNEL PROTECTION 3.

EROSION AND/OR SCOUR 2.

1. ALIGNMENT

61. CHANNEL 8

G G N G N

MED

SUFF

60 FT.

9. STREAM BED COMPOSITION :

ROCK

222. APPROACHES 7

OTHER 9.

ALIGNMENT 8.

SIGNS 7.

SETTLEMENT 6.

EROSION 5.

SURFACING 4.

APPROACH GUARDRAIL 3.

RELIEF JOINTS 2.

1. APPROACH SLABS G

N G G G G G G N

223. RETAINING WALL N

OTHER 6.

SETTLEMENT OR DEFLECTION 5.

EROSION AND/OR SCOUR 4.

FOUNDATION 3.

WEEP HOLES 2.

1. WALL

36. TRAFFIC AND SAFETY FEATURES

APPROACH GUARDRAIL ENDS D.

APPROACH GUARDRAILS C.

TRANSITIONS B.

BRIDGE RAILINGSA. 1

N N N

TRAFFIC SAFETY RATING CODES

0 - Does not meet standards or a safety feature is required and none is provided.

1 - Meets currently acceptable standards.

N - Not applicable or a safety feature is not required.

59.2,6 WEATHERING STEEL. WEB STIFFENER WELDED TO FLANGES AT

FLOOR BEAMS. BOLTS ON HORIZONTAL FLANGES, FIELD SPLICES,

AND GUSSET PLATE TO BRACING CONNECTIONS ARE INSTALLED

UPSIDE DOWN. MINOR FLAKING AT WEST SIDE OF WEST GIRDER

AT SPLICE SOUTH OF PIER.

59.6 PIER DIAPHRAGM BOX BEAM DOES NOT APPEAR TO BE

WEATHERING STEEL.

60.1 MINOR CRACKING OF ABUTMENT BREASTWALLS. DIAGONAL

CRACKING (UP TO 0.03" WIDE) OF SOUTH ABUTMENT BREASTWALL.

MINOR POPOUT WITH EXPOSED FORM TIES ON SOUTH ABUTMENT

BREASTWALL.

60.3 MINOR CRACKING WITH EFFLORESCENCE ON BEARING SEAT FOR

EAST GIRDER AT NORTH ABUTMENT.

60.6 MINOR TO MODERATE DETERIORATION OF MORTAR JOINTS WITH

MINOR VEGETATION GROWTH. MASONRY PIECES HAVE FALLEN

OFF EXTERIOR OF SOUTHEAST WINGWALL.

60.13 MINOR STAINING ON TOP OF COLUMN ON NORTH FACE FROM

WEATHERING STEEL. CRACK WITH EFFLORESCENCE ON TOP OF

PIER EXTENDING DOWN BOTH FACES OF PIER. UP TO 0.04"

VERTICAL CRACKING WITH EFFLORESCENCE ON BOTH FACES OF

CENTER PIER.

60.16 PIER CAST DIRECTLY INTO BEDROCK.

222.1 DIAGONAL CRACKING (UP TO 0.04" WIDE) OF SOUTH APPROACH

SLAB. MINOR DAMAGE TO ARMOR ANGLE AT NORTH APPROACH

SLAB END IN SOUTHBOUND LANE.

222.3 MINOR TO MODERATE DETERIORATION OF MORTAR JOINTS WITH

EFFLORESCENCE. VEGETATION ALONG CURBLINE. CAPSTONE AT

SOUTHEAST PARAPET END IS DISPLACED.

222.4 MODERATE CRACKING OF APPROACH PAVEMENT.

222.7 "STACK ROCK CREEK" POSTED AT BOTH APPROACHES.

STRUCTURE LOAD RATING STRUCTURE NO. 5140-183P

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 15 14 25 23

HS 26 24 44 40

TYPE 3 26 24 43 39

TYPE 3S2 29 26 48 44

TYPE 3-3 31 28 51 46

DESIGN LOADING: H15 (M13.5)

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION:

LOAD RATING CONTROLLED BY:

REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-183P

STRUCTURE IDENTIFICATION

(201) PARK: BLUE RIDGE PARKWAY (1) STATE: ....................................... 374 - NORTH CAROLINA (NC)

(202) STRUCTURE NAME: .......... STACK ROCK CREEK BRIDGE (2) STATE HWY. AGENCY DIST:

(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 011 - AVERY

(204) STRUCTURE NUMBER: ..... 5140-183P (4) CITY/PLACE CODE:

(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:

(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... STACK ROCK CREEK

(207) ROAD SECTION NO: .......... 183P (7) FACILITY CARRIED: .................. BLUE RIDGE PARKWAY

(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5140183P0000000

(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 0.51 MILES FROM U.S. ROUT

(210) OPERATING UNIT: ............. PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)

(211) PROJECT NO(S): ................ 02H3J14 (11) MILE POINT: ............................. 304.63 (KM PT 490.03)

(212) DRAWING NUMBERS: ....... 2H3JI4 (27) YEAR BUILT:

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD

(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

3 - STEEL

03 - GIRDER & FLOOR BEAM SYSTEM

140.0 FT (42.7 M)

284.0 FT (86.6 M)

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

5 - OTHER

6 - N/A

1 - CONCRETE CAST-IN-PLACE

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 2

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. 1 - MONOLITHIC CONCRETE

B) TYPE MEMBRANE: ................. 0 - NONE

C) TYPE PROTECTION: .............. 0 - NONE

(218) IS SALT USED?: ..................... NO

LOAD RATING AND POSTING

(31) DESIGN LOAD: ................. 2 - H15 (M13.5) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION

(66) INVENTORY RATING: ...... 26.0 TONS (24.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED

(64) OPERATING RATING: ...... 44.0 TONS (39.9 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 7/11 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... YES

INSP. EVERY: 24 MONTHS - LAST INSP. : 7/11 (220) SPECIAL STUDY TYPE: 0 - NONE

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-183P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE: ............................. 36°05'27.20" (51) CURB TO CURB WIDTH: ........... 34.5 FT (10.5 M)

(17) LONGITUDE: ......................... 81°49'11.10" (52) DECK WIDTH: ............................ 38.0 FT (11.6 M)

(19) DETOUR LENGTH: ............... 10 MI (16 KM) (32) APPR. ROADWAY WIDTH: ........ 34.0 FT (10.4 M)

(28A) LANES ON STRUCT: .......... 02 (213) APPR. PAVEMENT WIDTH: ..... 22.0 FT (6.7 M)

(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 6.0 FT (1.8 M)

(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 6.0 FT (1.8 M)

(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN

(29) AVG. DAILY TRAFFIC: .......... 2000 (34) SKEW ANGLE: ............................ 0 °

(30) YEAR OF ADT: ...................... 2007 (35) DECK FLARE?: ........................... NO

(114) FUTURE ADT: ..................... 2200 (47) TOTAL HORIZ. CLEARANCE: .... 34.5 FT (10.5 M)

(115) YEAR OF FUTURE ADT: ..... 2027 (50) SIDEWALKS:

(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)

(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 2 - MOUNTED ON PARAPET

(111) ABUT. OR PIER PROT: ....... MATERIAL: .............................. 2 - CONCRETE/ALUMINUM

DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL

LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 99.9 FT (99.9 M) (215) BRIDGE RAIL HEIGHT: ............ 3.08 FT (0.94 M)

(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)

(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:

(59) SUPERSTRUCTURE:

(60) SUBSTRUCTURE:

(61) CHANNEL:

(62) CULVERT: ........................... N

(222) APPROACHES:

(223) RETAINING WALL: ........... N

(36) TRAFFIC SAFETY FEAT: ... 1NNN

(75A) TYPE OF WORK:

(75B) WORK DONE BY:

(76) IMPROVEMENT LENGTH: ..

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

N

8 - Stable; scour above top of fo

2 - REHAB/RECONSTRUCTION

D - MINOR

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

2008 - APPROACHES REPAVED

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

http:81�49'11.10 http:36�05'27.20

APPENDIX STRUCTURE NO. 5140-183P

PHOTOGRAPHS STRUCTURE NO. 5140-183P

PHOTO #1 - LOOKING SOUTHBOUND TOWARD ASHEVILLE

FLOW

PHOTO #2 - WEST (UPSTREAM) SIDE

PHOTO #3 - GENERAL TOP SIDE VIEW LOOKING NORTH

PHOTO #4 - GENERAL UNDERSIDE VIEW OF NORTH SPAN LOOKING

SOUTH

PHOTO #5 - DISPLACED CAPSTONE AT SOUTHEAST APPROACH

PARAPET END

PHOTO #6 - CRACKING OF SOUTH APPROACH SLAB, NORTHBOUND

LANE

PHOTO #7 - TYPICAL CONDITION OF PATCHING AT SOUTH APPROACH,

NORTH APPROACH SIMILAR

PHOTO #8 - CRACKING OF SOUTH APPROACH PAVEMENT; NOTE

VEGETATION GROWTH ALONG CURB LINE

PHOTO #9 - EXPANSION JOINT OVER SOUTH

ABUTMENT

PHOTO #10 - COLLISION DAMAGE TO WEST

BRIDGE RAIL NEAR SOUTH ABUTMENT; NOTE

TYPICAL MISSING NUT FROM RAIL POST

PHOTO #11 - COLLISION DAMAGE TO WEST BRIDGE RAIL NEAR SOUTH

PHOTO #12 - TYPICAL ABRASION OF DECK; NOTE FADING OF

CENTERLINE STRIPING

PHOTO #13 - TYPICAL CRACKING OF DECK

PHOTO #14 - DECK JOINT OVER NORTH

PHOTO #15 - CRACKING OF NORTH APPROACH PAVEMENT

PHOTO #16 - SETTLEMENT AT NORTH APPROACH, SOUTH APPROACH

SIMILAR

PHOTO #17 - TYPICAL CONDITION OF

PARAPET MORTAR JOINTS, NORTHEAST

PARAPET SHOWN; NOTE CRACKING

PHOTO #18 - DAMAGE TO ARMOR ANGLE AT

NORTH END OF NORTH APPROACH SLAB IN

SOUTHBOUND LANE; NOTE SPALL

PHOTO #19 - DAMAGED DRAINAGE GRATE AT NORTHEAST APPROACH

PHOTO #20 - GENERAL VIEW OF SOUTH ABUTMENT

PHOTO #21 - TILTING TOWARD SOUTH OF EAST BEARING PAD AT

SOUTH ABUTMENT

PHOTO #22 - WEST BEARING PAD AT SOUTH ABUTMENT

PHOTO #23 - CRACKING WITH

EFFLORESCENCE ON SOUTH ABUTMENT

BREASTWALL

PHOTO #24 - POPOUT AT FORM TIE

LOCATIONS ON SOUTH ABUTMENT

PHOTO #25 - TYPICAL CRACKING WITH

EFFLORESCENCE ON DECK OVERHANGS,

WEST OVERHANG IN SOUTH SPAN SHOWN

PHOTO #26 - TYPICAL EFFLORESCENCE ON

DECK UNDERSIDE CONSTRUCTION JOINTS,

SOUTH SPAN SHOWN

PHOTO #27 - TYPICAL DIAPHRAGM TO GIRDER

CONNECTION, EAST SIDE OF SOUTH SPAN

SHOWN; NOTE LATERAL BRACING AND

DIAPHRAGM BOLTS ARE UPSIDE DOWN

PHOTO #28 - TYPICAL DIAPHRAGM TO

LATERAL BRACE CONNECTION, EAST SIDE OF

SOUTH SPAN SHOWN; NOTE LATERAL

BRACING AND DIAPHRAGM BOLTS ARE

UPSIDE DOWN

PHOTO #29 - BIRD NEST ON EAST GIRDER IN

SOUTH SPAN

PHOTO #30 - FLAKING OF WEATHERING SIDE

ON WEST SIDE OF WEST GIRDER AT SPLICE

PLATE SOUTH OF PIER; NOTE BOLTS ARE

UPSIDE DOWN

PHOTO #31 - GENERAL VIEW OF PIER

PHOTO #32 - BASE OF PIER CAST INTO

BEDROCK

PHOTO #33 - VERTICAL CRACKING OF PIER,

SOUTH FACE

PHOTO #34 - NEOPRENE BEARING AT PIER

PHOTO #35 - TYPICAL CONNECTION OF BOX

BEAM AT PIER TO WEST GIRDER

PHOTO #36 - CRACKING OF HAUNCH AT

SOUTH SIDE OF PIER

PHOTO #37 - VERTICAL CRACKING OF PIER,

NORTH FACE

PHOTO #38 - HATCH ON NORTH FACE OF

CENTER BOX BEAM

PHOTO #39 - LATERAL BRACING CONNECTION

AT NORTH SIDE OF PIER; NOTE BOLTS ARE

UPSIDE DOWN

PHOTO #40 - TYPICAL CONDITION OF

STIFFENERS PLATES, EAST SIDE OF WEST

GIRDER IN NORTH SPAN SHOWN

PHOTO #41 - TYPICAL SPLICE PLATE

CONNECTIONS, EAST SPLICE IN NORTH SPAN

SHOWN; NOTE BOLTS ARE UPSIDE DOWN

PHOTO #42 - TYPICAL CRACKING ON

EXTERIOR FACE OF CURB, WEST SIDE OF

NORTH SPAN SHOWN

PHOTO #43 - GENERAL VIEW OF NORTH ABUTMENT

PHOTO #44 - TYPICAL CONDITION OF BEARINGS, EAST BEARING AT

NORTH ABUTMENT SHOWN

PHOTO #45 - VERTICAL CRACKING OF NORTH

ABUTMENT BREASTWALL

PHOTO #46 - CRACKING WITH

EFFLORESCENCE ON WEST SIDE OF EAST

BEARING SEAT AT NORTH ABUTMENT

PHOTO #47 - LOOKING UPSTREAM FROM

DECK

PHOTO #48 - LOOKING DOWNSTREAM FROM

DECK