Birdge_Insp_Rpt_5140-178P.pdf

PDF 2 MB Posted

Attached to
Blue Ridge Parkway - WMS NC (1) Federal contract opportunity
Solicitation number
DTFH71-13-R-00013
Issued by
Department of Transportation Federal Highway Administration

About this file

Bridge Inspection Report - 5140-178P

View the file

Other files for this federal contract opportunity

Other files attached to Blue Ridge Parkway - WMS NC (1), newest first.
File Type Posted
Amendment_002_-_NPS_BLRI_WMS_NC(1).pdf PDF
Amendment_001_-_NPS-BLRI_WMS_NC(1).pdf PDF
Birdge_Insp_Rpt_5140-180P.pdf PDF
Birdge_Insp_Rpt_5140-091P.pdf PDF
Birdge_Insp_Rpt_5140-182P.pdf PDF
RFP_Solicitation_-_PRA-BLRI_WMS_NC(1).pdf PDF
VETS-100A-Form.pdf PDF
Birdge_Insp_Rpt_5140-181P.pdf PDF
Birdge_Insp_Rpt_5140-183P.pdf PDF
Birdge_Insp_Rpt_5140-099P.pdf PDF
ADV_Offeror's_Qualifications_Form.doc DOC document
Birdge_Insp_Rpt_5140-176P.pdf PDF
Birdge_Insp_Rpt_5140-177P.pdf PDF
FP03_Eng_.pdf PDF
Plans_-_PRA-BLRI_WMS_NC(1).pdf PDF
FP03_Errata.pdf PDF
Birdge_Insp_Rpt_5140-179P.pdf PDF
REV_Synopsis_Notice_-_PRA-BLRI_WMS_NC(1).doc DOC document
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BRIDGE INSPECTION REPORT

ROUGH RIDGE BRIDGE

BLUE RIDGE PARKWAY OVER RAVINE

BLUE RIDGE PARKWAY

LS

STRUCTURE NO. 5140-178P

INSPECTION TYPE: ROUTINE

INSPECTION DATE: 6/23/11

Report prepared by: ED

MILE POINT: 303.01

Federal Highway Administration KILOMETER POINT: 487.67 Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP http://www.efl.fhwa.dot.gov/FLHBO/BIP

STRUCTURE SUMMARY STRUCTURE NO. 5140-178P

ROUGH RIDGE BRIDGE INSPECTION DATE: 6/23/11

BRIDGE IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ....... P/S CONCRETE CONTINUOUS NO. OF MAIN SPANS:

MAIN SPAN TYPE: ............... BOX GIRDER - SINGLE or SPREAD NO. OF APPR. SPANS:

# OF BEAMS, MAIN SPAN: .. 1 STRUCT. TOTAL LENGTH: .. 360.0 FT (109.7 M)

DECK TYPE: ......................... CONCRETE CAST-IN-PLACE MAX. SPAN LENGTH: .......... 180.0 FT (54.9 M)

WEARING SURFACE: .......... MONOLITHIC CONCRETE DECK WIDTH: ...................... 38.8 FT (11.8 M)

ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH: ..... 34.5 FT (10.5 M)

PIER FOUNDATION(S): ........ OTHER YEAR BUILT:

ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. N/A

PROJ./PLAN REF. NO: ......... BR2H10 / BR2H10 SKEW ANGLE: ..................... 0 °

NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL: ........ NO

STRUCTURE HISTORY: ...... 2008- LONGITUDINAL JOINT IN NORTH APPROACH SLAB HAS BEEN RESEALED.

LOCATION

BLUE RIDGE PARKWAY MILE POINT: ..................... 303.01 (KM PT 487.67)

STATE: ................................. NORTH CAROLINA LOCATION: 1.98 MILES FROM U.S. ROUTE 22

FACILITY CARRIED: ............ BLUE RIDGE PARKWAY

FEATURE INTERSECTED: .. RAVINE

STRUCTURE EVALUATION SUMMARY

This prestressed box girder bridge is in good condition overall. Problems include an accumulation of debris and gravel in the deck joints, deterioration of the mortar joints of the masonry wingwalls and parapets, and displacement of the aluminum joint armor at the corner of the southwest curb. An interior inspection of the box girder revealed minor but widespread cracking on the underside of the top slab, with up to 1/16" cracks on the web walls and diaphragms.

Corrective action should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future.

INSPECTION TEAM: J. THOMAS, R. TAYLOR (VOLKERT, INC.)

CONDITION ASSESSMENT:

JOE THOMAS, P.E., FIELD TEAM LEADER

REPORT REVIEW:

MARCUS MILLER, P.E., LEAD STRUCTURAL ENGINEER 703-404-6252

REPORT APPROVAL: DATE: 12/19/11

JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140-178P

A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

D226 PRIORITY OF IMPROVEMENT

ITEM

NO.

MAINTENANCE RECOMMENDATIONS

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT COST

UNIT

ESTIMATE

COST

PRELIM.

60.6, 222.3 REPOINT MORTAR JOINTS OF MASONRY WINGWALLS AND APPROACH PARAPETS

AS NECESSARY.

20 LF

58.2 CLEAN GRAVEL FROM EXPANSION JOINTS AT ABUTMENTS. REPAIR ALUMINUM

HARDWARE AT JOINT IN CURB BETWEEN APPROACH SLAB AND BRIDGE.

1 LS

PRELIM. MAINTENANCE TOTAL :

ITEM

NO.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST ESTIMATES

PRELIM. COST

REHAB. RECONSTR.

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL:

PRELIM. REHABILITATION TOTAL:

PRELIM. RECONSTRUCTION TOTAL: ...

TOTAL ITEMIZED COSTS:

PRELIMINARY ESTIMATE TOTAL* :

(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)

REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.

FIELD INSPECTION REPORT STRUCTURE NO. 5140-178P

CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223

N NOT APPLICABLE 3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.

9 EXCELLENT CONDITION Fatigue cracks in steel or shear cracks in concrete may be present.

8 VERY GOOD CONDITION - no problems noted. 2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present

7 GOOD CONDITION - some minor problems. or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

6 SATISFACTORY CONDITION - structural elements show some minor deterioration. 1 “IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal

5 FAIR CONDITION - all primary structural elements are sound but may have movement affecting structure stability. Structure is closed to traffic but minor section loss, cracking, spalling, or scour. corrective action may return structure to light service.

4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour. 0 FAILED CONDITION - out of service; beyond corrective action.

CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

58. DECK 6 ITEM REFERENCE AND REMARKS

F1. DECK SLAB

F2. EXPANSION JOINTS

N3. WEARING SURFACE

G4. RIDEABILITY

G5. CURBS, SIDEWALKS, AND MEDIAN

G6. PARAPETS AND/OR RAILINGS

F7. DRAINS AND DRAINAGE

N8. UTILITIES

G9. DEFLECTION AND/OR VIBRATION

N10. OTHER

59. SUPERSTRUCTURE 7

G

2. GIRDERS OR BEAMS

1. BEARING DEVICES

G

N3. ARCH(ES) OR SLAB(S)

N4. FLOOR BEAMS AND STRINGERS

N5. TRUSSES

G6. DIAPHRAGMS AND BRACING

N7. PAINT

N8. FASCIA(E)

G9. DEFLECTION AND/OR VIBRATION

G10. ALIGNMENT

N11. OTHER

60. SUBSTRUCTURE 7

58.1 MINOR CRACKING, SPALLING, AND SCALING ON DECK SURFACE.

MINOR TRANSVERSE CRACKING WITH EFFLORESCENCE ON

UNDERSIDE OF OVERHANGS. SEE ALSO 59.2.

58.2 MODERATE ACCUMULATION OF SILT AND GRAVEL ON EXPANSION

JOINT STRIP SEALS AT ABUTMENTS. MODERATE CRACKING OF

GROUT AT JOINTS. ALUMINUM JOINT ARMOR IS BENT AT

SOUTHWEST PARAPET. MINOR

58.5 MINOR CRACKING AND SCALING ON CURBS, ESPECIALLY NEAR RAIL

POSTS. ONE SEVERE CRACK ON SOUTH END OF EAST CURB IN

VICINITY OF EXPANSION JOINT.

58.6 ALUMINUM BRIDGE RAIL HAD SEVERAL "EXPANSION JOINTS" THAT

WERE FULLY CLOSED OR NEARLY SO AT TIME OF INSPECTION. (AIR

TEMP WAS 80 DEG).

58.7 PAVED WATERWAYS ALONG NORTHWEST WINGWALL AND AT

CULVERT NEAR SOUTH ABUTMENT HAVE SETTLED AND ARE

BREAKING UP. CULVERT IS UNDERMINED. MINOR PONDING AT

SOUTHWEST CORNER OF DECK NOTED IN PREVIOUS INSPECTION

(UNABLE TO VERIFY DURING THIS INSPECTION).

ABUTMENTS

BREASTWALLS OR COLUMNS 1. G

PILE BENTS 2. N

CAPS AND/OR BEARING SEATS 3. G

BACKWALLS AND/OR BULKHEADS 4. G

FOUNDATIONS 5. G

WINGWALLS 6. F

WEEP HOLES 7. N

EXPANSION JOINTS 8. F

EROSION AND/OR SCOUR 9. G

SETTLEMENT OR DEFLECTION 10. G

SLOPE PROTECTION 11. N

OTHER 12. N

PIER(S)

WALLS AND/OR COLUMNS 13. G

PILE BENTS 14. N

CAPS AND/OR BEARING SEATS 15. G

FOUNDATIONS 16. N

EROSION AND/OR SCOUR 17. G

SETTLEMENT OR DEFLECTION 18. G

OTHER 19. N

ITEM REFERENCE AND REMARKS

STREAM BED COMPOSITION : 9.

AVERAGE CLEAR OPENING 8.

NORMAL VELOCITY 7.

ADEQUACY OF OPENING 6.

OTHER 5.

WATERWAY OBSTRUCTIONS 4.

CHANNEL PROTECTION 3.

EROSION AND/OR SCOUR 2.

ALIGNMENT 1.

61. CHANNEL N

222. APPROACHES 7

OTHER 9.

ALIGNMENT 8.

SIGNS 7.

SETTLEMENT 6.

EROSION 5.

SURFACING 4.

APPROACH GUARDRAIL 3.

RELIEF JOINTS 2.

1. APPROACH SLABS G

G F G G G N G N

223. RETAINING WALL 8

OTHER 6.

SETTLEMENT OR DEFLECTION 5.

EROSION AND/OR SCOUR 4.

FOUNDATION 3.

WEEP HOLES 2.

1. WALL G

G N G G N

36. TRAFFIC AND SAFETY FEATURES

APPROACH GUARDRAIL ENDS D.

APPROACH GUARDRAILS C.

TRANSITIONS B.

BRIDGE RAILINGSA. 1

TRAFFIC SAFETY RATING CODES

0 - Does not meet standards or a safety feature is required and none is provided.

1 - Meets currently acceptable standards.

N - Not applicable or a safety feature is not required.

59.2 BOX GIRDER EXTERIOR: MINOR DIAGONAL CRACKING OF TOP OF

WEB AT NORTH CORNERS. EFFLORESCENCE PRESENT AT

NORTHEAST CORNER.

BOX GIRDER INTERIOR: BOX GIRDER IS DIVIDED INTO THREE

CELLS. DEBRIS FROM CONSTRUCTION LEFT INSIDE BOX GIRDER.

ALL CRACK LENGTHS LISTED ARE APPROXIMATE.

UNDERSIDE OF TOP SLAB: TRANSVERSE CRACKING ON WEST

CELL NEAR CENTER DIAPHRAGM, SOUTH SPAN. TRANSVERSE

CRACKING WITH EFFLORESCENCE NEAR ABUTMENTS. 15'

LONGITUDINAL CRACK WITH EFFLORESCENCE ON EAST CELL,

NORTH SPAN. DIAGONAL CRACK WITH EFFLORESCENCE ON EAST

CELL, SOUTH SPAN. MINOR HONEYCOMBING IN EAST CELL, NORTH

SPAN NEAR PIER.

BOTTOM SLAB: 20' MINOR LONGITUDINAL CRACK ON CENTER CELL,

SOUTH SPAN, NEAR PIER. MINOR GOUGE IN BOTTOM SLAB, NORTH

SPAN, CENTER CELL, APPEARS TO HAVE BEEN PURPOSELY

GROOVED AFTER CONCRETE HARDENED TO ELIMINATE AREA OF

PONDING INSIDE BOX GIRDER.

59.2 LONGITUDINAL CRACKING ON EXTERIOR WEBS: 20' CRACK ON

EAST WEB, SOUTH SPAN, 1' FROM TOP, BEGINNING 15' FROM

CENTER PIER. SIMILAR CRACK (8' LONG) ON WEST WEB, 30' FROM

PIER (UNABLE TO VERIFY DURING THIS INSPECTION).

INTERIOR AND EXTERIOR WEB WALLS: VERTICAL CRACKING WITH

EFFLORESCENCE ON SEVERAL LOCATIONS. MINOR LONGITUDINAL

CRACKING IN VICINITY OF END DIAPHRAGMS IN SEVERAL

LOCATIONS. MINOR DIAGONAL CRACKING ON TOP OF DIAPHRAGMS

AND WEB WALLS AT CONSTRUCTION JOINTS IN SEVERAL

LOCATIONS. SEVERAL DIAGONAL CRACKS UP TO 1/16" ON WEB

WALLS ON EXTERIOR CELLS OF NORTH SPAN, EXTENDING ACROSS

ABUTMENT DIAPHRAGM. SOME CRACKS EXTEND BACK

APPROXIMATELY 12' ALONG WEB WALL AT CONSTRUCTION JOINT

BETWEEN CEILING AND WALL.

59.6 MINOR TRANSVERSE CRACKING ON END DIAPHRAGMS. MINOR

VERTICAL CRACKING ON PIER DIAPHRAGMS; CRACKS ORIGINATE

AT VENTILATION TUBES; MINOR CRACKING ON DIAPHRAGMS AT

CORNERS OF ACCESS OPENINGS.

59.9 NOTICEABLE VIBRATION WHEN RECREATIONAL VEHICLES CROSS

BRIDGE.

60.1 MINOR EFFLORESCENCE ON SOUTH ABUTMENT BREASTWALL.

ADDITIONAL ITEM REFERENCE AND REMARKS

60.3 KEY AT NORTH ABUTMENT (WHICH PREVENTS LATERAL MOVEMENT OF SUPERSTRUCTURE WITH RESPECT TO ABUTMENT) EXTENDS OUTWARD (SOUTHWARD) FROM FACE OF BREASTWALL, APPROXIMATELY 2" ADDITIONAL FROM TIME OF CONSTRUCTION. KEY AT SOUTH ABUTMENT SIMILAR. SOIL ON BOTH ABUTMENT BEARING

SEATS.

60.5 PREVIOUSLY NOTED EXPOSED FOOTING APPEARS TO BE RUBBLE FROM PRIOR BRIDGE SUBSTRUCTURE.

60.6, 222.3 MODERATE TO SEVERE CRACKING OF JOINT MORTAR IN SEVERAL LOCATIONS.

60.8 NO FILLER IN JOINT BETWEEN WINGWALL AND APPROACH PARAPETS, SOUTHEAST CORNER. SOUTHWEST AND

NORTHEAST JOINTS ARE MORTARED IN.

60.9 MODERATE EROSION AND MINOR SLOPE FAILURE AT SOUTHWEST WINGWALL.

222.1 MINOR LONGITUDINAL CRACKING ON APPROACH SLABS.

222.2,4,6 MINOR SETTLEMENT AND DETERIORATION OF APPROACH PAVEMENT AT BOTH APPROACHES. VEGETATION

GROWTH IN NORTH APPROACH SLAB JOINT.

STRUCTURE LOAD RATING STRUCTURE NO. 5140-178P

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 20 18 33 30

HS 36 33 60 55

TYPE 3 41 37 68 62

TYPE 3S2 44 40 74 67

TYPE 3-3 46 42 77 70

DESIGN LOADING: HS20 (MS18)

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION:

LOAD RATING CONTROLLED BY:

REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-178P

STRUCTURE IDENTIFICATION

(201) PARK: BLUE RIDGE PARKWAY (1) STATE: ....................................... 374 - NORTH CAROLINA (NC)

(202) STRUCTURE NAME: .......... ROUGH RIDGE BRIDGE (2) STATE HWY. AGENCY DIST:

(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 011 - AVERY

(204) STRUCTURE NUMBER: ..... 5140-178P (4) CITY/PLACE CODE:

(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:

(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... RAVINE

(207) ROAD SECTION NO: .......... 178P (7) FACILITY CARRIED: .................. BLUE RIDGE PARKWAY

(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5140178P0000000

(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 1.98 MILES FROM U.S. ROUT

(210) OPERATING UNIT: ............. PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)

(211) PROJECT NO(S): ................ BR2H10 (11) MILE POINT: ............................. 303.01 (KM PT 487.67)

(212) DRAWING NUMBERS: ....... BR2H10 (27) YEAR BUILT:

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD

(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

6 - P/S CONCRETE CONTINUOUS

06 - BOX GIRDER - SINGLE or SPREAD

180.0 FT (54.9 M)

360.0 FT (109.7 M)

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

5 - OTHER

5 - OTHER

1 - CONCRETE CAST-IN-PLACE

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 0

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. 1 - MONOLITHIC CONCRETE

B) TYPE MEMBRANE: ................. 0 - NONE

C) TYPE PROTECTION: .............. 0 - NONE

(218) IS SALT USED?: ..................... NO

LOAD RATING AND POSTING

(31) DESIGN LOAD: ................. 5 - HS20 (MS18) (41) LOAD RESTRICTION: ......... R - POSTED (OTHER)

(66) INVENTORY RATING: ...... 36.0 TONS (32.7 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED

(64) OPERATING RATING: ...... 60.1 TONS (54.5 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 6/11 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO

INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-178P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(51) CURB TO CURB WIDTH: ........... 34.5 FT (10.5 M)

(16) LATITUDE: ............................. 36°05'49.00"

(17) LONGITUDE: ......................... 81°48'03.80"

(19) DETOUR LENGTH: ............... 10 MI (16 KM)

(28A) LANES ON STRUCT:

(28B) LANES UNDER STRUCT: ... 00

(42A) SERVICE ON: ..................... 1 - HIGHWAY

(42B) SERVICE UNDER: .............. 0 - OTHER

(29) AVG. DAILY TRAFFIC:

(30) YEAR OF ADT:

(114) FUTURE ADT:

(115) YEAR OF FUTURE ADT:

(101) PARALLEL STRUCTURE: ... N - NONE

(38) NAVIGATION CONTROL?: ... N

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M)

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M)

(111) ABUT. OR PIER PROT:

LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 0.0 FT (0.0 M)

(56) LEFT: ......................... 0.0 FT (0.0 M)

(52) DECK WIDTH:

(32) APPR. ROADWAY WIDTH:

(213) APPR. PAVEMENT WIDTH:

LEFT SHOULDER:

RIGHT SHOULDER:

(33) BRIDGE MEDIAN:

(34) SKEW ANGLE:

(35) DECK FLARE?:

(47) TOTAL HORIZ. CLEARANCE:

(50) SIDEWALKS:

LEFT :

RIGHT :

(214) BRIDGE RAIL TYPE:

RAIL CONFIGURATION:

MATERIAL:

DESIGN TYPE:

(215) BRIDGE RAIL HEIGHT:

(53) MIN. VRT. CLEAR. OVER DECK:

(54) MIN. VRT. UNDERCLEARANCE:

38.8 FT (11.8 M)

28.0 FT (8.5 M)

22.0 FT (6.7 M)

3.0 FT (0.9 M)

3.0 FT (0.9 M)

0 - NO MEDIAN

0 °

NO

34.5 FT (10.5 M)

0.0 FT (0.0 M)

0.0 FT (0.0 M)

2 - MOUNTED ON PARAPET

2 - CONCRETE/ALUMINUM

1 - CONTINUOUS RAIL

2.92 FT (0.89 M)

99.99 FT (99.99 M)

0.00 FT (0.00 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:

(59) SUPERSTRUCTURE:

(60) SUBSTRUCTURE:

(61) CHANNEL: .......................... N

(62) CULVERT: ........................... N

(222) APPROACHES:

(223) RETAINING WALL:

(36) TRAFFIC SAFETY FEAT: ... 1111

(75A) TYPE OF WORK:

(75B) WORK DONE BY:

(76) IMPROVEMENT LENGTH: ..

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

N

N

N - Not over waterway.

1 - MAINTENANCE

D - MINOR

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

2008- LONGITUDINAL JOINT IN NORTH APPROACH SLAB HAS BEEN RESEALED.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

http:81�48'03.80 http:36�05'49.00

APPENDIX STRUCTURE NO. 5140-178P

PHOTOGRAPHS STRUCTURE NO. 5140-178P

PHOTO #1 - LOOKING NORTHBOUND TOWARD BLOWING ROCK

FLOW

PHOTO #2 - WEST SIDE

PHOTO #3 - GENERAL TOP SIDE VIEW LOOKING SOUTH

PHOTO #4 - GENERAL UNDERSIDE VIEW OF NORTH SPAN LOOKING

SOUTH

PHOTO #5 - GENERAL VIEW OF DECK JOINT AT

NORTH ABUTMENT; NOTE GRAVEL

ACCUMULATION

PHOTO #6 - SPALLING ALONG EAST SIDE OF

NORTH APPROACH SLAB; NOTE CONDITION

OF POURED JOINT SEALANT

PHOTO #7 - SETTLEMENT AND

DETERIORATION OF NORTH APPROACH SLAB

AT JOINT; NOTE VEGETATION GROWTH

PHOTO #8 - DETERIORATION OF MORTAR AT

NORTHEAST PARAPET

PHOTO #9 - TYPICAL LONGITUDINAL

CRACKING OF DECK, NORTHBOUND LANE

NEAR NORTH ABUTMENT SHOWN

PHOTO #10 - SLEEVE MISSING FROM LOWER,

WEST RAIL NEAR CENTER PIER

PHOTO #11 - TYPICAL CRACKING OF DECK

NEAR SOUTH ABUTMENT SHOWN

PHOTO #12 - GENERAL VIEW OF DECK JOINT

AT SOUTH ABUTMENT; NOTE GRAVEL

ACCUMULATION

PHOTO #13 - CRACKING AND SPALLING OF

SOUTH APPROACH SLAB

PHOTO #14 - BENT EXPANSION JOINT ARMOR

AT SOUTHWEST PARAPET; NOTE PATCHING

ON CURB AND GRAVEL ACCUMULATION IN

JOINT

PHOTO #15 - GENERAL VIEW OF NORTH ABUTMENT

PHOTO #16 - TYPICAL CONDITION OF BEARING AT NORTH ABUTMENT,

BEARING #3 SHOWN

PHOTO #17 - DISPLACED SHEAR KEY AT NORTH ABUTMENT

PHOTO #18 - CRACKING OF WEST SIDE OF BOX GIRDER NEAR NORTH

ABUTMENT

PHOTO #19 - CRACKING WITH

EFFLORESCENCE ON EAST EXTERIOR WEB

OF BOX GIRDER AT NORTH ABUTMENT

PHOTO #20 - GENERAL VIEW OF PIER

PHOTO #21 - CRACKING WITH

EFFLORESCENCE ON EAST OVERHANG, WEST

OVERHANG SIMILAR

PHOTO #22 - DRAINAGE PIPE ON WEST SIDE

OF SOUTH ABUTMENT SLOPE; NOTE

UNDERMINING OF HEADWALL

PHOTO #23 - GENERAL VIEW OF SOUTH ABUTMENT

PHOTO #24 - TYPICAL CONDITION OF BEARING PADS AT SOUTH

ABUTMENT, EAST BEARING SHOWN

PHOTO #25 - DISPLACED SHEAR KEY AT SOUTH ABUTMENT

PHOTO #26 - GENERAL VIEW OF CENTER CELL, NORTH SPAN,

LOOKING NORTH

PHOTO #27 - TYPICAL CRACKING OF END DIAPHRAGM NEAR NORTH

ABUTMENT, WEST CELL SHOWN

PHOTO #28 - CRACKING WITH EFFLORESCENCE ON WEST WEB AND

PIER DIAPHRAGM IN SOUTH SPAN

PHOTO #29 - GENERAL VIEW OF END

DIAPHRAGM AT SOUTH ABUTMENT, CENTER

CELL

PHOTO #30 - CRACKING OF NORTH FACE OF

END DIAPHRAGM IN CENTER CELL, SOUTH

SPAN

PHOTO #31 - TYPICAL TRANSVERSE

CRACKING WITH EFFLORESCENCE ON SLAB

UNDERSIDE, CENTER CELL OF SOUTH SPAN

SHOWN

PHOTO #32 - TYPICAL LONGITUDINAL

CRACKING OF FLOOR SLAB NEAR PIER,

CENTER CELL SHOWN

PHOTO #33 - TYPICAL CRACKING OF INTERMEDIATE DIAPHRAGM AT

ACCESS HATCH, CENTER CELL, SOUTH SPAN SHOWN

PHOTO #34 - PREVIOUSLY NOTED EXPOSED FOOTING AT SOUTH

ABUTMENT APPEARS TO BE RUBBLE FROM PRIOR BRIDGE

SUBSTRUCTURE