Birdge_Insp_Rpt_5140-179P.pdf
PDF 3 MB Posted
- Attached to
- Blue Ridge Parkway - WMS NC (1) Federal contract opportunity
- Solicitation number
- DTFH71-13-R-00013
About this file
Bridge Inspection Report - 5140-179P
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_002_-_NPS_BLRI_WMS_NC(1).pdf | ||
| Amendment_001_-_NPS-BLRI_WMS_NC(1).pdf | ||
| Birdge_Insp_Rpt_5140-180P.pdf | ||
| Birdge_Insp_Rpt_5140-091P.pdf | ||
| Birdge_Insp_Rpt_5140-182P.pdf | ||
| RFP_Solicitation_-_PRA-BLRI_WMS_NC(1).pdf | ||
| VETS-100A-Form.pdf | ||
| Birdge_Insp_Rpt_5140-181P.pdf | ||
| Birdge_Insp_Rpt_5140-183P.pdf | ||
| Birdge_Insp_Rpt_5140-099P.pdf | ||
| ADV_Offeror's_Qualifications_Form.doc | DOC document | |
| Birdge_Insp_Rpt_5140-176P.pdf | ||
| Birdge_Insp_Rpt_5140-178P.pdf | ||
| Birdge_Insp_Rpt_5140-177P.pdf | ||
| FP03_Eng_.pdf | ||
| Plans_-_PRA-BLRI_WMS_NC(1).pdf | ||
| FP03_Errata.pdf | ||
| REV_Synopsis_Notice_-_PRA-BLRI_WMS_NC(1).doc | DOC document |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BRIDGE INSPECTION REPORT
WILSON CREEK BRIDGE
BLUE RIDGE PARKWAY OVER WILSON CREEK
BLUE RIDGE PARKWAY
LS
STRUCTURE NO. 5140-179P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 6/25/11
Report prepared by: ED
MILE POINT: 303.50
Federal Highway Administration KILOMETER POINT: 488.25 Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP http://www.efl.fhwa.dot.gov/FLHBO/BIP
STRUCTURE SUMMARY STRUCTURE NO. 5140-179P
WILSON CREEK BRIDGE INSPECTION DATE: 6/25/11
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... P/S CONCRETE CONTINUOUS NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... BOX GIRDER - SINGLE or SPREAD NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. 1 STRUCT. TOTAL LENGTH: .. 380.0 FT (115.8 M)
DECK TYPE: ......................... CONCRETE CAST-IN-PLACE MAX. SPAN LENGTH: .......... 150.0 FT (45.7 M)
WEARING SURFACE: .......... MONOLITHIC CONCRETE DECK WIDTH: ...................... 38.8 FT (11.8 M)
ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH: ..... 34.5 FT (10.5 M)
PIER FOUNDATION(S): ........ SPREAD FTG ON BEARING MAT'L YEAR BUILT:
ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. N/A
PROJ./PLAN REF. NO: ......... BR2H10 / 00000 SKEW ANGLE: ..................... 0 °
NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL: ........ NO
STRUCTURE HISTORY: ...... 1988-BRIDGE RAIL REPAIR/REPLACEMENT. 2008-APPROACH PAVEMENT REPAIRED.
LOCATION
BLUE RIDGE PARKWAY MILE POINT: ..................... 303.50 (KM PT 488.25)
STATE: ................................. NORTH CAROLINA LOCATION: 1.62 MILES FROM U.S. ROUTE 22
FACILITY CARRIED: ............ BLUE RIDGE PARKWAY
FEATURE INTERSECTED: .. WILSON CREEK
STRUCTURE EVALUATION SUMMARY
This prestressed concrete box girder bridge is in good condition overall. Problems include deterioration of the joint material between the parapets and wingwalls, and moderate erosion at the south abutment slope which is also causing failure of the concrete waterway. Inside the box girder there are several minor cracks and efflorescence throughout. Also, it appears that the box is being accessed by unauthorized personnel and used as living quarters.
Access hatches should be fixed with locks. Since the previous inspection, the heavy vegetation growth in the north and south spans has been removed.
Corrective action should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future.
INSPECTION TEAM: J. THOMAS, R. TAYLOR (VOLKERT, INC.)
CONDITION ASSESSMENT:
JOE THOMAS, P.E., FIELD TEAM LEADER
REPORT REVIEW:
MARCUS MILLER, P.E., LEAD STRUCTURAL ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 12/19/11
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140-179P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
D226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
60.9 STABILIZE ERODED AREA OF SOUTH ABUTMENT SLOPE WITH ADDITIONAL RIP
RAP.
5 CY
60.12 RECONSTRUCT DRAINAGE CHUTE AT SOUTH ABUTMENT SLOPE. 40 LF
60.8, 222.3 INSTALL JOINT FILLER MATERIAL AT PARAPET/WINGWALL JUNCTION. 20 LF
59.2 INSTALL LOCKS ON BOX GIRDER ACCESS HATCHES. 2 LS
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL:
PRELIM. REHABILITATION TOTAL:
PRELIM. RECONSTRUCTION TOTAL: ...
TOTAL ITEMIZED COSTS:
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 5140-179P
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
N NOT APPLICABLE
9 EXCELLENT CONDITION
8 VERY GOOD CONDITION - no problems noted.
7 GOOD CONDITION - some minor problems.
6 SATISFACTORY CONDITION - structural elements show some minor deterioration.
5 FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
1 “IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
0 FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
58. DECK 6
1. DECK SLAB F
2. EXPANSION JOINTS G
3. WEARING SURFACE N
4. RIDEABILITY G
5. CURBS, SIDEWALKS, AND MEDIAN G
6. PARAPETS AND/OR RAILINGS G
7. DRAINS AND DRAINAGE G
8. UTILITIES N
9. DEFLECTION AND/OR VIBRATION G
10. OTHER N
59. SUPERSTRUCTURE 7
1. BEARING DEVICES
2. GIRDERS OR BEAMS
3. ARCH(ES) OR SLAB(S)
4. FLOOR BEAMS AND STRINGERS
5. TRUSSES
6. DIAPHRAGMS AND BRACING
7. PAINT
8. FASCIA(E)
9. DEFLECTION AND/OR VIBRATION
10. ALIGNMENT
11. OTHER (VEGETATION GROWTH)
60. SUBSTRUCTURE
ABUTMENTS
1. BREASTWALLS OR COLUMNS
2. PILE BENTS
3. CAPS AND/OR BEARING SEATS
4. BACKWALLS AND/OR BULKHEADS
5. FOUNDATIONS
6. WINGWALLS
7. WEEP HOLES
8. EXPANSION JOINTS
9. EROSION AND/OR SCOUR
10. SETTLEMENT OR DEFLECTION
11. SLOPE PROTECTION
12. OTHER (PAVED WATERWAY)
PIER(S)
13. WALLS AND/OR COLUMNS
14. PILE BENTS
15. CAPS AND/OR BEARING SEATS
16. FOUNDATIONS
17. EROSION AND/OR SCOUR
18. SETTLEMENT OR DEFLECTION
19. OTHER
G G N N N G N N G G G
G N G N N G N F F G N P
G N G N G G N
58.1
58.5
58.6
59.1
59.2
59.6
59.11
ITEM REFERENCE AND REMARKS
MINOR TO MODERATE LONGITUDINAL CRACKING AND SCALING ON
DECK SURFACE NEAR ABUTMENTS; SOME AREAS OF MODERATE
SCALING. MINOR DIAGONAL CRACKING OF SURFACE AT ALL
ABUTMENT CORNERS. MINOR CRACKING WITH EFFLORESCENCE
ON UNDERSIDE OF OVERHANGS AND ON UNDERSIDE OF DECK IN
SEVERAL LOCATIONS INSIDE BOX GIRDER. SEE ALSO 59.2. 8" DIA.
AREA OF DELAMINATION AT NORTHWEST CORNER OF NORTH SPAN.
MINOR CRACKING OF CONCRETE CURBS WITH EFFLORESCENCE.
MINOR COLLISION DAMAGE TO EAST RAIL IN NORTH SPAN.
MINOR DETERIORATION OF BEARING MATERIAL AT BOTH
ABUTMENTS. 1" DISPLACEMENT AT NORTH ABUTMENT; 2" AT
SOUTH ABUTMENT.
MINOR SPALLING THROUGHOUT BOX GIRDER EXTERIOR.
INSIDE: FORM BOARDS AND OTHER DEBRIS LEFT IN SOUTH SPAN.
HONEYCOMBED AREA ON UNDERSIDE OF TOP SLAB AT SOUTH END
WITH REBAR AND EFFLORESCENCE VISIBLE, WEST CELL. 10'
LONGITUDINAL CRACK WITH EFFLORESCENCE ON UNDERSIDE OF
TOP SLAB, EAST AND WEST CELLS, ADJACENT TO SOUTH END
DIAPHRAGM. NORTHEAST-MOST CELL HAS MINOR CRACKING WITH
EFFLORESCENCE ON TOP SLAB AND EXTERIOR WEB. WEST SIDE
EXTERIOR FILLET IN NORTH SPAN IS SEVERELY HONEYCOMBED
(UNABLE TO VERIFY DURING THIS INSPECTION).
*CENTER SPAN COULD NOT BE ACCESSED DURING THIS
INSPECTION.
MINOR CRACKING OF END DIAPHRAGMS; MINOR EFFLORESCENCE
ON BOTH END DIAPHRAGMS IN EAST CELL.
VEGETATION GROWTH ALONG NORTH AND SOUTH SPANS HAS
BEEN REMOVED SINCE THE PREVIOUS INSPECTION.
FIELD INSPECTION REPORT STRUCTURE NO. 5140-179P
ITEM REFERENCE AND REMARKS
STREAM BED COMPOSITION : 9.
AVERAGE CLEAR OPENING 8.
NORMAL VELOCITY 7.
ADEQUACY OF OPENING 6.
OTHER 5.
WATERWAY OBSTRUCTIONS 4.
CHANNEL PROTECTION 3.
EROSION AND/OR SCOUR 2.
ALIGNMENT 1.
61. CHANNEL 8
G G G G N
MED
SUFF
25 FT.
STONES
222. APPROACHES 7
OTHER 9.
ALIGNMENT 8.
SIGNS 7.
SETTLEMENT 6.
EROSION 5.
SURFACING 4.
APPROACH GUARDRAIL 3.
RELIEF JOINTS 2.
1. APPROACH SLABS G
G G G G G G G N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION 5.
EROSION AND/OR SCOUR 4.
FOUNDATION 3.
WEEP HOLES 2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDS D.
APPROACH GUARDRAILS C.
TRANSITIONS B.
BRIDGE RAILINGSA. 1
60.6 MINOR EFFLORESCENCE ON WINGWALLS.
60.8, 222.3 MODERATE CRACKING OF MORTAR JOINTS WITH MINOR
EFFLORESCENCE. NO JOINT FILLER BETWEEN PARAPETS AND
WINGWALLS.
60.9,12 MODERATE EROSION OF SOUTH ABUTMENT SLOPE IS
CONTRIBUTING TO FAILURE OF ASPHALT DRAINAGE CHUTE. MINOR
EROSION AT NORTHWEST ABUTMENT/WINGWALL JUNCTION.
222.1 MINOR LONGITUDINAL CRACKING OF APPROACH SLABS.
222.2 POURED JOINT AT SOUTH APPROACH SLAB HAS MODERATE
ADHESION FAILURE ALLOWING LEAKAGE.
222.4 MINOR TO MODERATE CRACKING OF APPROACH PAVEMENT.
TRAFFIC SAFETY RATING CODES
N
Does not meet standards or a safety feature is required and none is provided.
Meets currently acceptable standards.
Not applicable or a safety feature is not required.
STRUCTURE LOAD RATING STRUCTURE NO. 5140-179P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 20 18 34 31
HS 36 33 60 55
TYPE 3 36 33 60 55
TYPE 3S2 40 37 68 61
TYPE 3-3 43 39 71 65
DESIGN LOADING: HS20 (MS18)
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-179P
STRUCTURE IDENTIFICATION
(201) PARK: BLUE RIDGE PARKWAY (1) STATE: ....................................... 374 - NORTH CAROLINA (NC)
(202) STRUCTURE NAME: .......... WILSON CREEK BRIDGE (2) STATE HWY. AGENCY DIST:
(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 011 - AVERY
(204) STRUCTURE NUMBER: ..... 5140-179P (4) CITY/PLACE CODE:
(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:
(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... WILSON CREEK
(207) ROAD SECTION NO: .......... 179P (7) FACILITY CARRIED: .................. BLUE RIDGE PARKWAY
(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5140179P0000000
(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 1.62 MILES FROM U.S. ROUT
(210) OPERATING UNIT: ............. PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)
(211) PROJECT NO(S): ................ BR2H10 (11) MILE POINT: ............................. 303.50 (KM PT 488.25)
(212) DRAWING NUMBERS: ....... 00000 (27) YEAR BUILT:
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD
(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
6 - P/S CONCRETE CONTINUOUS
06 - BOX GIRDER - SINGLE or SPREAD
150.0 FT (45.7 M)
380.0 FT (115.8 M)
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
1 - CONCRETE CAST-IN-PLACE
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 1 - MONOLITHIC CONCRETE
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... NO
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 5 - HS20 (MS18) (41) LOAD RESTRICTION: ......... R - POSTED (OTHER)
(66) INVENTORY RATING: ...... 36.0 TONS (32.7 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 60.1 TONS (54.5 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 6/11 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-179P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 36°06'04.50" (51) CURB TO CURB WIDTH: ........... 34.5 FT (10.5 M)
(17) LONGITUDE: ......................... 81°49'44.10" (52) DECK WIDTH: ............................ 38.8 FT (11.8 M)
(19) DETOUR LENGTH: ............... 10 MI (16 KM) (32) APPR. ROADWAY WIDTH: ........ 29.0 FT (8.8 M)
(28A) LANES ON STRUCT: .......... 02 (213) APPR. PAVEMENT WIDTH: ..... 21.0 FT (6.4 M)
(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 5.0 FT (1.5 M)
(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 3.0 FT (0.9 M)
(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(29) AVG. DAILY TRAFFIC: .......... 2000 (34) SKEW ANGLE: ............................ 0 °
(30) YEAR OF ADT: ...................... 2007 (35) DECK FLARE?: ........................... NO
(114) FUTURE ADT: ..................... 2200 (47) TOTAL HORIZ. CLEARANCE: .... 34.5 FT (10.5 M)
(115) YEAR OF FUTURE ADT: ..... 2027 (50) SIDEWALKS:
(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)
(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 2 - MOUNTED ON PARAPET
(111) ABUT. OR PIER PROT: ....... MATERIAL: .............................. 2 - CONCRETE/ALUMINUM
DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 3.00 FT (0.91 M)
(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)
(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL:
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ... 1111
(75A) TYPE OF WORK:
(75B) WORK DONE BY:
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
8 - Stable; scour above top of fo
1 - MAINTENANCE
D - MINOR
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
1988-BRIDGE RAIL REPAIR/REPLACEMENT. 2008-APPROACH PAVEMENT REPAIRED.
(231) ADDITIONAL CONSIDERATIONS:
HATCH AT NORTH ABUTMENT HAS NO LOCK.
(330) ADDITIONAL CONFIG. INFO.:
http:81�49'44.10 http:36�06'04.50
APPENDIX STRUCTURE NO. 5140-179P
PHOTOGRAPHS STRUCTURE NO. 5140-179P
PHOTO #1 - LOOKING NORTHBOUND TOWARD BLOWING ROCK
PHOTO #2 - WEST (UPSTREAM) SIDE
PHOTO #3 - GENERAL TOP SIDE VIEW LOOKING NORTH
PHOTO #4 - GENERAL UNDERSIDE VIEW OF CENTER SPAN LOOKING
SOUTH
PHOTO #5 - GENERAL VIEW OF ADHESION
FAILURE IN JOINT FILLER AT SOUTH
APPROACH
PHOTO #6 - ADHESION FAILURE IN JOINT
FILLER AT SOUTH APPROACH
PHOTO #7 - TYPICAL PARAPET AND WINGWALL
JOINT, SOUTHEAST JOINT SHOWN; NOTE
LACK OF JOINT FILLER MATERIAL
PHOTO #8 - CRACKING OF EAST SIDE OF
SOUTH APPROACH SLAB, WEST SIDE SIMILAR
PHOTO #9 - JOINT AT SOUTH ABUTMENT
PHOTO #10 - CRACKING OF SOUTHWEST
DECK CORNER
PHOTO #11 - CRACKS NEAR SOUTH
ABUTMENT IN NORTHBOUND LANE,
SOUTHBOUND LANE SIMILAR
PHOTO #12 - TYPICAL CRACKING OF DECK,
SOUTHBOUND LANE OF SOUTH SPAN SHOWN
PHOTO #13 - COLLISION DAMAGE TO EAST RAIL IN NORTH SPAN
PHOTO #14 - DIAGONAL CRACKING OF NORTHWEST DECK CORNER
PHOTO #15 - DIAGONAL CRACKING OF
NORTHEAST DECK CORNER
PHOTO #16 - DECK JOINT AT NORTH
ABUTMENT
PHOTO #17 - GENERAL VIEW OF NORTH
APPROACH JOINT
PHOTO #18 - TYPICAL LONGITUDINAL
CRACKING OF APPROACH SLAB, NORTH
APPROACH SLAB SHOWN
PHOTO #19 - TYPICAL CONDITION OF MORTAR JOINTS ON PARAPETS,
NORTHEAST PARAPET SHOWN
PHOTO #20 - GENERAL VIEW OF NORTH ABUTMENT
PHOTO #21 - CRACKING WITH EFFLORESCENCE ON EAST DECK
OVERHANG AT NORTH ABUTMENT
PHOTO #22 - GENERAL VIEW OF DETERIORATION OF BEARING
MATERIAL AT NORTH ABUTMENT
PHOTO #23 - DETERIORATION OF BEARING
MATERIAL AT NORTH ABUTMENT, EAST SIDE
SHOWN
PHOTO #24 - VEGETATION REMOVED FROM
EAST SIDE OF BRIDGE
PHOTO #25 - VEGETATION REMOVED FROM
WEST SIDE OF BRIDGE
PHOTO #26 - GENERAL VIEW OF NORTH PIER
PHOTO #27 - GENERAL VIEW OF SOUTH PIER;
NOTE GRAFFITI, NORTH PIER SIMILAR
PHOTO #28 - TYPICAL CRACKING WITH
EFFLORESCENCE ON DECK OVERHANGS,
EAST RAIL NEAR SOUTH PIER SHOWN
PHOTO #29 - GENERAL VIEW OF SOUTH ABUTMENT
PHOTO #30 - EROSION OF SOUTH ABUTMENT SLOPE; NOTE
DETERIORATION OF PAVED WATERWAY
PHOTO #31 - GENERAL VIEW OF DETERIORATION OF BEARING
MATERIAL AT SOUTH ABUTMENT
PHOTO #32 - DETERIORATION OF BEARING MATERIAL AT SOUTH
ABUTMENT
PHOTO #33 - CRACKING WITH EFFLORESCENCE ON EAST DECK
OVERHANG AT SOUTH ABUTMENT
PHOTO #34 - CRACKING WITH EFFLORESCENCE ON WEST DECK
OVERHANG AT SOUTH ABUTMENT
PHOTO #35 - TYPICAL CONDITION OF WINGWALLS, SOUTHWEST
WINGWALL SHOWN
PHOTO #36 - GENERAL VIEW OF CENTER CELL IN SOUTH SPAN; NOTE
DEBRIS AND PAINT
PHOTO #37 - FORM BOARDS AND CONSTRUCTION DEBRIS IN CENTER
CELL, SOUTH SPAN NEAR SOUTH ABUTMENT
PHOTO #38 - EFFLORESCENCE ON END DIAPHRAGM IN CENTER CELL
SOUTH SPAN
PHOTO #39 - GENERAL VIEW OF SOUTH PIER DIAPHRAGM IN CENTER
CELL
PHOTO #40 - GENERAL VIEW OF SOUTH ABUTMENT DIAPHRAGM IN
WEST CELL; NOTE CRACKING WITH EFFLORESCENCE
PHOTO #41 - CRACKING WITH EFFLORESCENCE ON TOP SLAB
UNDERSIDE IN WEST CELL NEAR SOUTH ABUTMENT
PHOTO #42 - GENERAL VIEW OF HONEYCOMBING WITH EXPOSED
REBAR ON TOP SLAB UNDERSIDE IN WEST CELL NEAR SOUTH
ABUTMENT; NOTE CRACKING WITH EFFLORESCENCE
PHOTO #43 - HONEYCOMBING WITH EXPOSED REBAR ON TOP SLAB
UNDERSIDE IN WEST CELL NEAR SOUTH ABUTMENT
PHOTO #44 - GENERAL VIEW LOOKING NORTH IN WEST CELL TOWARD
SOUTH PIER DIAPHRAGM
PHOTO #45 - CRACKING WITH EFFLORESCENCE ON SOUTH ABUTMENT
DIAPHRAGM IN EAST CELL
PHOTO #46 - LONGITUDINAL CRACKING OF TOP SLAB UNDERSIDE IN
EAST CELL NEAR SOUTH ABUTMENT
PHOTO #47 - GENERAL VIEW LOOKING SOUTH IN CENTER CELL IN
NORTH SPAN
PHOTO #48 - TYPICAL CRACKING OF NORTH ABUTMENT DIAPHRAGM IN
CENTER CELL
PHOTO #49 - TYPICAL CRACKING OVER ACCESS HATCH IN
INTERMEDIATE DIAPHRAGMS, EAST CELL IN NORTH SPAN SHOWN
PHOTO #50 - CRACKING WITH EFFLORESCENCE ON NORTH
ABUTMENT DIAPHRAGM IN EAST CELL
PHOTO #51 - CRACKING WITH EFFLORESCENCE ON TOP SLAB
UNDERSIDE IN EAST CELL NEAR NORTH ABUTMENT
PHOTO #52 - GENERAL VIEW LOOKING SOUTH IN WEST CELL IN
NORTH SPAN
PHOTO #53 - EXPOSED REBAR ON EAST WALL
IN WEST CELL NEAR INTERMEDIATE
DIAPHRAGM
PHOTO #54 - GENERAL VIEW OF CRACK IN
END DIAPHRAGM IN TOP SLAB UNDERSIDE IN
WEST CELL NEAR NORTH ABUTMENT
PHOTO #55 - CRACK IN TOP SLAB UNDERSIDE IN END DIAPHRAGM IN
WEST CELL NEAR NORTH ABUTMENT
PHOTO #56 - UPSTREAM CHANNEL
PHOTO #57 - DOWNSTREAM CHANNEL
File details come from the government source that posted it. Updated .