Section B - Supplies or Services/Prices

Line Item No.

Base Period

Option Period 1

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Option Period 3

Option Period 4

Description of Work

Unit of Issue

QTY*

Unit Price

Extended Price

GENERAL CONDITIONS

Scope Clarification and assistance

MH

Common Building Laborer

Electrician

Glazer

HVAC Mechanic

Painter

Paper Hanger

Plasterer

Tile Layer

Plumber

Carpenter (may include systems furniture installers)

Sheet Metal Mechanic (HVAC Duct Work)

Mason

Unskilled Laborers

Carpet Installer/Repairs

Concrete Finisher

Sprinkler Installer

Systems/Modular Furniture Installer

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Certified Asbestos Worker

Certified Lead Base Paint Removal

Certified IT equipment/cabling installer

Certified cctv/audio-visual equipment installer

DEMOLITION - Including incidental repairs and Disposal of material-25% non-standard work hours rate applied to demolition items involving only labor

Demo Concrete up to 6" thick, Hydraulic hammer

- mesh reinforced (slab)

SY

- Rod reinforced (slab)

Remove Existing Door and Frame

- from drywall

EA

- from masonry

Remove door only up to 3' x 7' including Hardware

Remove and reinstall door w/ hardware

Remove Lockset from existing Door

Remove door stop from wall or floor

Remove metal stud and drywall partition

SF

Remove metal stud and plaster partition

Remove masonry and plaster partition cu ft

Remove drywall from existing wood or metal studs

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Remove Wire mesh above suspended ceiling

Demo partition drywall Security w/ flattened exp metal

Remove chair rail, patch drywall or plaster as required

LF

Demo wainscoting

Demo railings and balusters

Demo Cabinets Wood or Metal

Demo Countertops

Demo lath and plaster up to 3" thick

Remove Wall covering Vinyl or Fabric (includes necessary wall repairs)

Remove bank type partition (unit includes post to post)

Remove Accoustical Ceiling Tile:

- including grid systems

- excluding grid system

Remove Carpet:

- glued down

- tacked down

Remove Carpet Pad:

- glued down

- tacked down

Remove resilient flooring (tile or sheet goods)

Remove existing cove base, 4 in. or 6 in.

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Remove Baseboard up to 8" to include shoe molding

Remove Shoe Molding

Remove abandoned outlets and thermostats

Remove ductwork, galvanized, includes insulation and hangers

LB

Remove condensing unit, up to 5 Tons, includes reclaiming and recycling of refrigerant.

Demo Lavatory any type plus 10' of pipe

Demo sink any type including 10' of pipe

Demo water closet any type including 10' of pipe

Remove and reset fixtures

Remove Urinals:

- wall mounted

- floor mounted

Demo Water Fountain:

- floor mounted

- wall mounted

Demo Piping, metal, with or without insulation:

- up to 2" diameter

- over 2" up to 4" diameter

- over 4" up to 8" diameter

Remove sprinkler head and piping up to 3'

Remove Sprinkler Piping - up to 12' above floor

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- 1/2" through 2" diameter

- 2-1/2" through 4" diameter

Demo Water Heater up to 50 gals

Demo Toilet Partitions

- Slate or Marble ( incl. one wall and one door)

- Hollow Metal or Solid Surface/Phenolic ( incl. one wall and one door)

Remove Ceramic Tile (Walls and Floors) any size tile:

- Thin set

- Mud set

DEMOLITION - All items remain the property of the government.

Remove snap switch and wiring (F & I blank cover)

Remove duplex receptacles and wiring :

from wall (F & I blank cover) from floor duct (F & I cap and plug with sheet metal plate approved by Building Manager, approximately 3" x 5")

Remove double duplex receptacles and wiring :

from floor duct (F & I cap and plug with sheet metal plate approved by Building Manager, approximately 3" x 5")

Remove telephone outlet and conduit :

from floor duct (F & I cap and plug with sheet metal plate approved by Building Manager, approximately 3" x 5")

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Remove conduit or wire mold (500,700,1500) up to 1-1/4" conduit, including conductors, back to origin

10 LF

Remove conduit 1-1/2" to 4", including conductors, back to origin

10 LF

Remove tele-power pole and wiring

Remove voice communication box

Demo transformer, oil filled or dry

- 10 to 15 kva 1 phase

- 30 to 45 kva 1 phase

- 3 to 15 kva 3 phase

- 25 to 30 kva 3 phase

- 45 kva 3 phase

Demo safety switches 250 or 600 volts, includes disconnecting wire, & pipe terminations:

- 30 amp

- 60 amp

- 100 amp

Remove fluorescent fixture and wiring :

- maximum 4 ft. long

- maximum 8 ft. long

Demo Panel Board up to 5 wire 277 volt 125 amp incl. breakers pipe terminations, and wire connects

Demo Panel Board up to 5 wire 480 volt 200 amp incl. breakers pipe terminations, and wire connects

Remove conduit or wire mold, including conductors, back to origin

- Wiremold raceway 500, 700, or 1500 and/or conduit up to 1-1/4"

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- Conduit 1-1/2" to 4"

Demo Wire, includs all wires in conduit

- #12 or #10

- #6 or #8

- #3 or #4

- 1/0 or 2/0

- 3/0 or 4/0

- 250, 300, or 350 MCM

- 400 or 500 MCM

Demo Wiremold raceway / conduit including conduit fittings and hangers

- Wiremold raceway 500, 700, or 1500 and/or conduit up to 1 "

- Wiremold raceway 3000 or 4000 and/or conduit larger than 1" up 2"

- Conduit larger than 2" up to 4"

Demo armored cable:

- #14, 2 or 3 wire

- #12, 2 or 3 wire

- #10, 2 or 3 wire

Demo Coaxial Cable including connectors

Demo Telephone/Computer cable including connectors

Remove incandescent fixture and wiring includes wire & flex condiut up to 20 lf

Remove exit light (F & I blank cover, if required)

Option Period 1

Option Period 2

Option Period 2

Option Period 3

RELOCATION - Includes maximum 50 ft. change in length of conduit and conductors

Relocate snap switch and wiring (F & I blank cover), up to 3 gang switch

Relocate duplex receptacles and wiring :

- from wall (F & I blank cover)

- from floor duct (F & I cap and plug with sheetmetal plate approved by Building Manager, approximately 3" x 5")

Relocate double duplex receptacles and wiring

- from floor duct (F & I cap and plug with sheetmetal plate approved by Building Manager, approximately 3" x 5")

Relocate telephone outlet box within limits of existing wiring (does not include connection or disconnection of service) :

- from floor duct (F & I cap and plug with sheetmetal plate approved by Building Manager, approximately 3" x 5")

Relocate tele-power pole, exclude. Conduit run & hookup if existing connection

Relocate voice communication box

Relocate (shift) light fixture in suspended ceiling (no elec disconnect)

Relocate fluorescent fixture and wiring (includes all work, conduit & wiring, max 10' relocation)

- stem, chain or pendent mounted

- recess mounted (lay-in)

- surface mounted

Relocate exit light (F & I blank cover, if required)

Relocate emergency light

Relocate incandescent fixture and wiring includes wire & flex condiut up to 20 lf

Option Period 1

Option Period 2

Option Period 2

Option Period 3

CUTTING AND PATCHING

Cut bottom of door to allow carpet installation:

- metal door

- wood door

Cut new opening for door or window in existing partition, includes finishing to match adjacent surfaces :

- Metal Stud and drywall

- Plaster (lath)

- Masonry / CMU (Straight Cut)

Concrete Core -drill up to 12 in. deep :

- Up to 4 in. diameter

- Cost added per inch for over 12" deep

Inch

Cut and chip new hole into existing floor duct for telephone or electrical installation

Excavate/Trench in existing concrete for utilities by hand up to 12" wide

CY

Saw cut Concrete per inch of depth

Patch underlayment for uneven flooring

Install concrete , includes properly sized WWF or Rebar:

- up to 4" thick

- over 4" and up to 6" thick

- over 6" and up to 8" thick

MASONRY

F & I masonry partition 4 in. CMU, w/struck joints without surface finish

Option Period 1

Option Period 2

Option Period 2

Option Period 3

F & I masonry partition 8 in. CMU, w/struck joints without surface finish

F & I Plaster finish on concrete block partition , per side

Repair Subfloor, Masonry, where damaged from walls or object removal.

F & I Brick masonry walls veneer 4" thick

Reinforcing for masonry walls

Parging of existing masonry or concrete walls

Stucco on Masonry

METALS

Expanded metal, steel, 9 gauge existing studs to secure with tamper proof screws, minimum 12 in. on center

Expanded metal, steel, 11 gauge existing studs to secure with tamper proof screws, minimum 12 in. on center

Same as 5.1 except from top of ceiling high wall to underside of next floor

Same as 5.2 except from top of ceiling high wall to underside of next floor

Furnish and Install Handrails - 2 Rails

- Wood

- Steel

- Aluminum

Install chain link fence up to 10 ft high, 9 gage with top and bottom rails with 2" (+/-) poles on 10" centers (+/-)

Fence Gate 3' wide for above fence with associated posts and hardware

FINISH CARPENTRY - All bookcases shall be 1 in. birch plywood shelves with solid hardwood nosing, 1/2 in. birch plywood backing, 2 -1/4" solid birch face trim with recessed standard and 4" toe kick plate, sections not to exceed 3 ft. long and 9 feet high with 5 shelves , 16 in. deep. Bookcases shall be painted 2 coats or stained and coated with 2 coats of polyurethane.

Option Period 1

Option Period 2

Option Period 2

Option Period 3

F & I custom bookcase (face equals - width x height)

SF of face

Refinish woodwork - strip, stain and clear finish:

- frames, chair rail, cove base and thresholds up to 8" wide

- doors, walls, ceilings, etc.

Strip, sand and apply 2 coats of polyurethane finish to window ledge

Refinish woodwork - strip and varnish :

- frames, chair rail, cove base and thresholds up to 8" wide

- doors, walls, ceilings, etc. per side

F & I, 1x6 Pine Board for window and door trim

F & I, Clamshell and colonial molding around window and doors

F & I, Hardwood Custom Base Cabinets (A.W.I. Custom Grade) finished top and bottom - Face frame - stain grade birch, oak, or maple

F & I, Hardwood Custom Wall Cabinets (A.W.I. Custom Grade) finished top and bottom - Face frame - stain grade birch, oak, or maple

F & I, Non-Custom Base Cabinets, hardwood, natural finish or paint grade, finished top and bottom

F & I, Non-Custom Wall Cabinets, hardwood, natural finish or paint grade, finished top and bottom

F & I Countertop, Laminate, 24" wide with back and side splash

F & I, Plywood Backboard (4' x 8 'x 3/4")

F&I Countertop, Solidsurface, 24” with back and side splash

Stain Wood Trim and two coats of poly

Stain Doors and Frames w/ two coats of poly, each side

F & I, Parque Flooring-Medium Grade

Blocking in wall (Treated with fire resistant paint)

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Furnish and Install Threshold

- Marble - Government Furnished Material

- Wood

INSULATION

F & I mineral fiber sound insulation, 3 1/2 in. thickness :

- unfaced

- foil faced

- Kraft paper faced

F & I Insulation Fiberglass walls, 3-1/2 in. thickness:

- unfaced

- foil faced

- Kraft faced

F & I Insulation Mineral Fiber Batts ceiling, Kraft faced 6" thick R19

Furnish and Install Acrylic Latex Caulk Cartridge type

- 1/4" x 1/2"

- 3/4" x 3/4"

- 1" x 1"

F & I Caulk and Sealant, Polysulfide, 2 parts, in place to make weather tight

Spray on Fire proofing

Pipe Insulation

1 inch

Option Period 1

Option Period 2

Option Period 2

Option Period 3

1.25 inch

1.5 inch

2inch

DOORS AND FRAMES

Contractor shall F & I silencers, hinges, and door stops. Doors and frames shall be primed and painted or polyurethane 2 coats. Door leaves not to exceed 3 ft. x 7 ft.

The following items are for installation (labor) only. If materials are required, i.e., not government furnished or reused from demo use other line items.

Install door and frame (Including necessary stud work for proper support.)

- drywall or plaster (3' x 7' Maximum size)

- masonry (4, 6, or 8 in.) (3' x 7' Maximum size)

- Drywall or plaster, double door (6' x 7' Maximum size)

- Masonry (4, 6, or 8 in.) double door (6' x 7' Maximum size)

- Install Door

F & I Metal Frame, single Door, B label (Including necessary stud work for proper support)

F & I Metal Frame, double door, B label (Including necessary stud work for proper support)

F & I hollow core interior wood door natural finish or paint-grade door (3' x 7' max size)

- Birch Face

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- Oak Face

- Cherry Face

- Walnut Face

F & I Solid core wood door, B label, natural finish or paint-grade door (3' x 7' max size)

- Birch Face

- Oak Face

- Cherry Face

- Walnut Face

F & I hollow metal door, B label

F & I Oak Pocket Door (3'x7') include trim

F & I Wood grain Laminated accordian doors

F & I Hollow core bi-fold birch finished doors

F & I Louver Pine 4' x 6'8" bifold doors

Additional Drywall repairs and finishes when inserting doors

HARDWARE

F & I door stop - floor, wall, or door mounted.

F & I door closer (match building standard)

F & I Heavy Duty door closer w/ hold open feature

F & I Kick Plates 12" x 36"

- Stainless steel, Medium duty commercial grade

- Bronze, Medium duty commercial grade

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- Brass, Medium duty commercial grade

F & I Push Plate and Door Pull (4" x 16")

- Stainless Steel, Medium duty commercial grade

- Bronze, Medium duty commercial grade

- Brass, Medium duty commercial grade

F & I metal louver in door (24" x 24" max.), includes cut opening

F & I Lite Kit (7"x22") in wood door

F & I Stainless Steel Latch Guard

F & I Big Eye (wide view peep hole)

F & I Heavy duty pinned Security hinges (set of three)

- Stainless Steel

- Brass

F & I Heavy Duty premium hinges, Brass

F & I Electric door release w/ release Button

F & I Sound attenuating door seals (door frame and threshold)

- Stainless or Brass

F & I lockset matching building standard (Kwickset, Russwin, Sargent, Schlage, Yale, or equivalent) private with 2 keys on or off building master with replaceable cylinder; (Federal Bldg. Only)

F & I cylindrical passage

F & I lockset with two keys :

- deadbolt, key on key

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- deadbolt, key on thumb turn

Furnish extra keys in conjunction with new lockset installation

Install government furnished lockset (labor only)

F & I keyless push button (5 button cypher type) deadbolt and night latch at least 1 in. throw, simplex series 900 type

F & I keyless push button (5 button cypher type) lock set with deadbolt and night latch at least 1 in throw with key override standard access control w/lever simplex type, simplex series 7000 type

F & I Electric Door Release low voltage incl. Transformer low voltage 18 ga wiring and push button

F & I PIV enabled card readers

F&I Low Energy Single Door Automatic Opener

PREMIUM ITEMS

Premium Closers, Bronze finish (furnish only)

Premium Deadlock, Bronze finish (furnish only)

Premium Latchset, Bronze finish (furnish only)

Premium Locks, Bronze finish (furnish only)

Premium Privacy Locks, Bronze finish (furnish only)

F&I Medeco interchangeable core, motise cylinders, with 2 keys on/off bldg.

master to be used with heavy duty mortise lockset shown below, finish to match standard

F&I CD-X09 High Security Lock

F & I Single action door release for High Security Locked doors, LKM-7000 or equal

F&I heavy duty mortise lockset, lever handle

- Stainless Steel finish

- US3 bright Brass

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- US10 bright Bronze

Best Lock Sets 93k Series (cylindrical) - 626 finish

Add for Brass

Best Lock Set 35H Series (Mortise)

Add for Brass

F & I Flush Bolts top and bottom - 626 finish

PR

Panic Device ( Fire Rated) - Surface Mounted

- 99 E.O. Von Duprin 26D Finish

- 99 E.O. Von Duprin US3 Finish

- 9927 E.O. Von Duprin 26D Finish

- 9927 E.O. Von Duprin US3 Finish

STANDARD PARTITIONS - **All line items include full floor-to-ceiling height (up to 12 ft.) partition; including 4" or 6" either existing integral metal base or new cove base, all required trim and molding, and painting of all non-vinyl surfaces, including priming & 2 coats of paint on all unpainted surfaces and 2 coats of paint or polyurethane on all unfinished surfaces and two coats on all previously painted surfaces

**All partitions over 12 ft will be increased by 1.5

F & I metal stud and drywall, 5/8 in. or 1/2 in. drywall both sides

$0.00

F & I standard partition, metal stud, 5/8 or 1/2 in. drywall one side only

F & I metal stud and plaster including wire lathe (2 sides)

F & I metal stud and 5/8" or 1/2" drywall bulkhead, minimum 6" - maximum 10"

F & I Zip Bead on top or edge of walls

Add for Wall built with Load bearing 16 gage metal studs

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Add for hat channel installed on existing C.M.U. wall in lieu of metal stud framing

F & I drywall on existing wood or metal studs

F & I window in drywall partition, safety glass, not to exceed 6 ft. wide by 5 ft. high (does not include cutting the hole) :

- wood frame

- metal frame

F & I wood chair rail - 2 piece

F & I Oak Chair rail - One piece.

F & I Oak Plinth block - match building standard

F & I Oak Door Casings - Match Building Standard

F & I 8" Oak Baseboard

F & I Oak Shoe Molding

FLOOR COVERINGS

F & I 4 in. or 6 in. resilient cove base with molded corners

F & I wood, metal or vinyl trim up to 6 in. wide, enamel, varnish or stain

F & I approved vinyl composite tile (VCT) (12 in. x 12 in. x 1/8 in.)

F & I Anti-static vinyl tile

Clean (strip /seal) and Apply two (2) coats of wax to new VCT

Handling of Delivered Carpeting (tiles or rolled)

Install gov't furnished carpet squares, contractor supplied adhesive per manufacturer

Install gov't furnished carpet squares by jacking up of furniture, contractor supplied adhesive per manufacturer

Install gov't furnished carpet roll goods :

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- glue down (contractor supplied adhesive per manufacturer)

- tack down over existing pad

F & I Carpet pad (tacked or glue down):

- 1/4 in. minimum, felt type

- 1/4 in. minimum, commercial foam

F & I carpet transition strip

Repair existing carpet

Patch carpet where partitions were removed up to 5 in. wide (gov't furnished carpet)

F & I Ceramic Tile

- thin set floors and walls

- mud set floors and walls

Seal Concrete Floor

Install epoxy floor

F&I install terrazzo style tile

CEILING SYSTEMS - Acoustical Ceiling Tile (ACT)

F & I New 2' x 2' ACT in existing grid (includes removal of existing tile)

- 2' x 2' ACT

- 2' x 4' ACT

- 2' x 5' ACT

F & I 2' x 2' Premium (revealed edge) ACT in existing grid (includes removal of existing tile)

F & I New ACT & Grid System (includes removal of existing)

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- 2' x 2' ACT

- 2' x 4' ACT

- 2' x 5' ACT

F & I 2'x 2' or 2' x 4' Premium (revealed edge) ACT & Grid System (metric or standard)

F & I spline ceiling tile - 1' x 1' - New

F & I spline ceiling tile - 1' x 1' - Remove & Reinstall

Install government furnished ceiling tiles in existing grid system

(such as 1 ft. X 5 ft., 2 ft. X 5 ft., 2 ft. X 2 ft., 2 ft. X 4 ft., 1 ft. X 1 ft., etc.)

Cut Ceiling tile and grid system to facilitate installation of wall partition above ceiling height, includes re-installation of ceiling system to new wall partition on both sides

Repair ceiling tile and grid system where partition was removed

PAINTING

Paint existing surfaces with two coats. The unit price shall be increased by 20% for painting over 12 ft. high. Painted materials include plaster, drywall, metal, wood, concrete and masonry. Includes moving furniture. Area shall be

Provide and apply paint :

- finish coats of paint, less than 1000 square feet

SQ FT

- finish coats of paint - using government furnished paint

- finish coats of paint, more than 1000 square feet

- Additional 2 coats due to unusual circumstances

Special Items :

- Paint door leaf, 3 ft x 7 ft maximum size, one side

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- Paint door leaf, 3 ft x 7 ft maximum size, both sides

- Paint doors and panels, dimensions other than standard

- Paint door frame, one side

- Paint door frame, two sides

- Paint door frame. Two side for 6' x7'

- Paint windows, mullions and trim, enamel or varnish

SF of open

- Paint wood, vinyl, or metal base up to 8 in. high, enamel or varnish

- Repair damaged or deteriorated plaster, less than 25 sq. YD. (includes removal of all damaged material and rebuild of wall; max 3 coats of plaster; 3 coats of paint)

- Repair damaged or deteriorated plaster, more than 25 sq. YD. (includes removal of all damaged material and rebuild of wall; max 3 coats of plaster; 3 coats of paint)

- Paint handrails (up to 3 rail systems)

- Paint stair risers (up to 6 feet wide X 1 foot high, 2 coats)

- Sand and spackle interior walls (above normal preparation)

- Thin coat of Plaster to smooth out walls Including sealing before and after

- Clean prep patch holes and paint existing ceiling grid system

WALL COVERINGS

F & I vinyl wall covering complying with Federal Specification CCC-W-408A :

- Heavy Weight (25-30 oz/SF) - New GWB Walls, Existing GWB Walls, & Existing Plaster Walls

- Medium Weight (20-24 oz/SF) - New GWB Walls, Existing GWB Walls, & Existing Plaster Walls

- Light Weight (12-15 oz/SF) - New GWB Walls, Existing GWB Walls, & Existing Plaster Walls

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Install government furnished vinyl wall covering (includes normal wall preparation)

Install government furnished fabric wall covering (includes normal wall prep)

F & I Floor to ceiling heavy Duty wall corner guards, vinyl

PARKING GARAGE / LOT PAINTING - Includes all necessary Cleaning & Preparation of Surface

Repainting of existing parking lines

Parking Space Markings (per character), up to 12"

Parking Space Markings (per character), larger than 12"

Parking Space Handicap Markings

Less than 20 parking spaces, mobilization cost

Remarking caution lines in warehouse, loading dock, storage areas by hand w/ tape

MISCELLANEOUS MATERIALS

Coaxial, BNC, quick disconnect or screw on with chrome or gold plated center pin

Multi-conductor type, up to 24 pair, terminated

F & I Toilet Seat cover Dispenser, S/S Surface mounted

F & I Toilet Tissue Dispenser, s/s single roll surface mounted

F & I Toilet Tissue Dispenser, s/s double roll surface mounted

F & I Towel Bar s/s up to 30" long

F & I Towel Dispenser s/s surface mounted

F & I Towel Dispenser s/s flush mounted

F & I Towel Dispenser and Waste Receptacle, recessed 18 gal capacity

F & I Soap dispenser, Chrome , liquid, surface mounted

Option Period 1

Option Period 2

Option Period 2

Option Period 3

F & I Soap dispenser, Chrome , liquid, countertop mounted

F & I Electric Hand Dryer, Medium grade - DOES NOT INCLUDE ELECTRIC CIRCUIT

F & I Shower Rod, hooks and Curtain

F & I Stainless Steel Channel Frame Mirror (18" x 30")

F & I Single towel dispensing, centerpull towel dispenser

F & I Soap Dispenser, plastic, liquid, surface mounted

WASTE AND VENT LINES (DWV) FURNISH AND INSTALL (including hangers @ 10" on center)

F & I DWV 1-1/2" Cast Iron no-hub

F & I DWV 2" Cast Iron no-hub

F & I DWV 3" Cast Iron no-hub

F & I DWV 4" Cast Iron no-hub

F & I Fiberglass Reinforced Panels (FRP) for bathrooms

F & I Fiberglass shower 36"x36"

PLUMBING FIXTURES FURNISH AND INSTALL

System includes rough-in supply waste and vent and shut off valves for connection to existing supply branches and mains, and all trim

F & I Water Closet, Wall mounted, Vitreous China, Bowl only with Flush Valve

F & I Water Closet, Floor Mounted, Vitreous China, Bowl only with Flush Valve

F & I Urinal - Wall mounted, Vitreous China, Bowl only with Flush Valve trim and hanger

F & I Automatic Flush sensor and operator for Urinal & water closets

F & I Lavatory, Porcelain, Enamel . on Cast Iron, wall hung with trim and concealed arm support size 20" x 18"

Option Period 1

Option Period 2

Option Period 2

Option Period 3

F & I Lavatory Porcelain Enamel on Cast Iron SB w/trim incl. plastic Laminated base cabinet and top w/ back splash door and Hardware up to 36" W. x 30" H w/ slope base for Handicap w soap dispenser hole

F & I s/s nominal size 25" x 22" sink, 6 to 8 inches deep.

F & I Sensor Faucet push front self closing

F & I Gooseneck lavatory Faucet w/ wrist handles

F & I Single Lever lavatory faucet

F & I Elongated Bowl, Direct-fed siphon jet flush action, gravity assisted flushing system floor mounted toilet with commercial grade seat

F & I Wall Mounted, Low Consumption, Siphon jet action, extended side Urinal

MECHANICAL

Relocate pneumatic thermostat

Relocate electric thermostat

F & I Thermostat, Pneumatic/Electric incl. up to 50 of wire / tubing

F & I Master unit with thermostat

F & I Slave unit

Install Government Furnished (GFE) moduline variable air volume box

Add sprinkler head up to 10 ft. (includes government furnished ceiling tile)

Relocate sprinkler head up to 10 ft. (includes government furnished ceiling tile)

F & I concealed sprinkle head

F & I Hinged sprinkle head escushin

Remove flexible ductwork. Cap abandoned opening with ductwork for an airtight seal up to 30'

F&I 1" thick glass fiber blanket duct insulation with vapor barrier

F&I pneumatic tubing between VAV boxes

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Convert slave terminal box to a master box with new thermostat, filter, and regulator

Relocate diffuser/grille withing limits of flex duct

F&I 12"X12" return air grilles in ceiling. Provide 1/2" x 1" x 1" aluminum lattice grilles and frame

F & I Register/Damper, 2X2 Lay in, up to 12" round

F&I 2' x 2' return air grilles in ceiling, does NOT include any ductwork

F & I 4" flexible, non insulated duct

F&I 6" round flexible, insulated, supply air, ductwork, 1" thick, 3/4" lb. density.

F & I Flex Duct insulated, over 6" and up to 12" dia

F & I Rigid Rectagular Duct, galvanized steel (includes fabrication, installation, fittings, tap in collars, joints, transitional fittings, allowance for flexible connections, supports, 1" thick insulation, sealing, leak testing) to commercial

- Under 2,000 LBS

- Over 2,000 LBS

F & I Rigid Round / Flat Oval Duct, galvanized steel (includes fabrication, installation, fittings, tap in collars, joints, transitional fittings, allowance for flexible connections, supports, 1" thick insulation, sealing, leak testing) to

- 4"

- 6"

- 8"

- 10"

- 12"

VAV box-inspect, clean, calibrate & report components in need of repair or replacement

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Fan Coil Unit - inspect, clean, calibrate & report components in need of repair or replacement

F & I Access panel, Hinged, lockable

- 12" x 12"

- 22" x 22"

F & I exhaust Fan 110cfm

F & I Interior Mounted exhaust fan 700cfm

Relocate, existing F/A accessory, includes up to 50 LF of new EMT and wire

- Fire Bell

- Pull Station

- Strobe Light

F & I New F/A accessory w/ up to 50 EMT and wire

- Fire Bell

- Pull Station

- Strobe Light

DOMESTIC WATER SUPPLY PIPING FURNISH AND INSTALL (including hangers & insulation)

F & I Copper Tubing type 'L'

- 1/2 inch

- 3/4 inch

- 1 inch

Option Period 1

Option Period 2

Option Period 2

Option Period 3

2 inch

VALVES-FURNISH AND INSTALL BRONZE OR COPPER

Valve, Ball or Gate

2 inch

Check Valve, sweat

F & I Shower Valves

HVAC - DUCT WORK

3 ton Computer Room Air Conditioninf Unit

2 Diffusers (200 to 300 CFM ea)

1 Return Grille (Sized for less than 600 FPM return velocity)

Ductwork (Approximately 20LF)

Insulation

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Hangers

5 ton Computer Room Air Conditioninf Unit

4 Diffusers (200 to 300 CFM ea)

1 Return Grille (Sized for less than 600 FPM return velocity)

Ductwork (Approximately 30LF)

10 ton Computer Room Air Conditioninf Unit

6 Diffusers (200 to 300 CFM ea)

2 Return Grille (Sized for less than 600 FPM return velocity)

Ductwork (Approximately 40LF)

15 ton Computer Room Air Conditioninf Unit

6 Diffusers (200 to 300 CFM ea)

2 Return Grille (Sized for less than 600 FPM return velocity)

Ductwork (Approximately 40LF)

5 Ton Split System

6 Diffusers (200 to 400 CFM ea)

Option Period 1

Option Period 2

Option Period 2

Option Period 3

4 Return Grille (Sized for less than 600 FPM return velocity)

Ductwork (Approximately 60LF)

F & I Emergency Drain Pan under AHU in Ceiling up to 50'

F & I one electric duct heater up to 10 kw

F & I 2" steel pipe

F & I 3/4" Copper condensate line

Additional Line Set

Duct take off with damper

ELECTRICAL WORK

The follow Items are for Installation (labor) only Gov't Furnish If material are required I.e. not Gov't furnished, additional line items are necessary

Install Gov't Furnished Coaxial Cable in existing Floor duct, up to 25 conductors per cable and or 2 O.D. not incl. Terminations

Install Gov't Furnished Coaxial Cable above suspended ceiling up to 25 conductors per cable and or 2 O.D. not incl. Terminations

Install Gov't Furnished Connectors / per conductor 24 pin multi-conductor type for cable pull

NEW WORK - Includes maximum 50 ft. length of conduit and conductors. Does not include panel connection.

F & I snap switch and wiring :

- single pole

- 3-way

- 4-way

Option Period 1

Option Period 2

Option Period 2

Option Period 3

F & I Switch Wall Dimmer 120/277 V 20 min Incandescent

F & I Switch Wall Dimmer 120/277 V 20 min florescent

F & I duplex receptacle and wiring :

- in wall

- in floor duct (existing hole)

F & I GFCI receptacle and wiring:

- in wall (new construction)

- in wall (existing wall)

F & I double duplex receptacle and wiring :

- in floor duct, monument type (existing hole)

F & I 220 volt dedicated receptacle and wire

F & I 120 volt, 20 amp dedicated receptacle and wire

F & I 120 volt, 20 amp dedicated isolated ground receptacle and wire

F & I dedicated circuit and junction box for systems furniture connection. Includes hook-up of systems furniture "whip" or "pigtail"; (Government or Agency furnished "whip")

F & I blank cover for telephone or electrical outlet :

- in floor duct (F&I cap & plug w/sheetmetal plate approved by Bldg. Manager., approx. 3"x5")

F & I telephone or computer outlet box & 10lf conduit in room (new construction)

- new construction

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- fished into existing wall

- in floor duct (existing hole)

F & I telephone or computer wiring, terminated at both ends, plenum rated

- Cat 5 or 5e cable

- Cat 6 cable

F & I conduit (EMT or wiremold) per ft. lengths beyond initial 50 ft. length :

- 3/4 in. conduit or #500 wiremold

- 1 in. conduit or #700 wiremold

- 1 1/4 in. conduit

- 1 1/2 in. conduit or #2100 wiremold

- 2 in. conduit or #3000 wiremold

- 2 1/2 in conduit

- 3 in. conduit

- 4 in. conduit

Install conduit fittings: LB, LL, or LR with covers :

- 3/4 in. diameter

- 1 in. diameter

- 1 1/2 in. diameter

- 2 in. diameter

- 3 in. diameter

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- 4 in. diameter

F & I conduit, RSC (Rigid Galvanized Steel) per ft. lengths beyond initial 50 ft. length :

- 1/2 in. conduit

- 3/4 in. conduit or #500 wiremold

- 1 in. conduit or #700 wiremold

- 1 1/4 in. conduit

- 1 1/2 in. conduit or #2100 wiremold

- 2 in. conduit or #3000 wiremold

- 3 in. conduit

- 4 in. conduit

RSC (Rigid Galvanized Steel) field bends:

- 1 1/4 in.

- 1 1/2 in.

- 2 in.

F & I RSC (Rigid Galvanized Steel) elbows:

- 1 1/4 in.

- 1 1/2 in.

- 2 in.

- 3 in.

- 4 in.

F & I single conductor :

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- # 12

- # 10

- # 8

- # 6

- # 4

- # 3

- # 2

- 1/0

- 2/0

- 3/0

- 4/0 AWG Copper, 600V

- 350 mcm

- 500 mcm

F & I circuit breaker panel, 3 phase, 100 amp, with main breaker or safety switch

- 32 breaker capacity, includes F & I 12 circuit breakers

- 42 breaker capacity, includes F & I 18 circuit breakers

- 200 amp 3 ph panel with 50% breakers installed w/remainder as blanked off spares.

- 400 amp 3 ph panel with 50% breakers installed and remainder blanked off spares.

F & I additional circuit breakers in existing panel, single or double pole :

- up to 30 amps

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- 35 to 60 amps

- 65 to 100 amps

F & I additional circuit breakers in existing panel, 3 pole 150 - 200 amp

Tie circuit into circuit breaker (breaker not included)

F & I tele-power pole and wire up to 50 ft. maximum

Install government furnished tele-power pole (Contractor furnished wiring up to 50 ft.)

F & I circuit breaker panel, 1 phase, 3 wire, with main breaker or safety switch :

- 100 amp

- 150 amp

- 200 amp

F & I Electric base board heates including controls (unit mount)

- 4 foot

- 8 foot

Furnish and Install conduit fittings: LB, LL, or LR with covers :

- 3/4 in. diameter

- 1 in. diameter

- 1 1/2 in. diameter

- 2 in. diameter

- 3 in. diameter

- 4 in. diameter

F & I heavy duty fused safety switch or circuit breaker, 3-pole, 600 V

Option Period 1

Option Period 2

Option Period 2

Option Period 3

- up to 30 amps

- 35 to 60 amps

- 65 to 100 amps

Fuses 200A, 600V, Cu

ENERGY EFFICIENT LIGHTING - Paragraph numbers refer to Contract Specification Section 16010.

F & I fluorescent tube lighting fixtures :

F & I 24 in. x 24 in. recessed fluorescent 2 U-Tube fixture with specular parabolic reflectors and electronic ballast (with energy saving 32 watt tubes).

F & I 12 in. x 48 in. recessed fluorescent 1 tube fixture with specular parabolic reflector and electronic ballast (with energy saving 32 watt tube). One ballast (included) shall be used for 2 or more fixtures, if possible.

F & I 24 in. x 48 in. recessed fluorescent 2 tube fixture with specular parabolic reflectors and electronic ballast (with energy saving 32 watt tubes).

F & I 24 in. x 24 in. surface mounted fluorescent 2 U-tube fixture with specular parabolic reflectors and electronic ballast (with energy saving 32 watt tubes).

F & I 12 in. x 48 in. surface mounted fluorescent 1 tube fixture with specular parabolic reflector and electronic ballast (with energy saving 32 watt tube). One ballast (included) shall be used for 2 or more fixtures, if possible.

F & I 24 in. x 48 in. surface mounted fluorescent 2 tube fixture with specular parabolic reflectors and electronic ballast (with energy saving 32 watt tubes).

F & I a T-8 electronic ballast into an existing fixture. Where a different type of ballast is being replaced, installation includes the installation of new T-8 type lamps in the fixture.

F & I specular parabolic reflector into existing 24 in. x 48 in. fixture. Where the number of fluorescent tubes is decreased, installation includes disconnecting the unneeded ballast's from the power supply and repositioning the tube connectors within the fixture.

F & I specular parabolic reflector into existing 24 in. x 24. in fixture. Where the number of fluorescent tubes is decreased, installation includes disconnecting the unneeded ballast's from the power supply and repositioning the tube

F & I specular parabolic reflector into existing 12 in. x 48 in. fixture. Where the number of fluorescent tubes is decreased, installation includes disconnecting the unneeded ballast's from the power supply and repositioning the tube

Option Period 1

Option Period 2

Option Period 2

Option Period 3

F & I compact fluorescent downlight fixture using PL lamp including reflector and electronic ballast.

F & I tungsten-halogen downlight fixture including reflector and electronic ballast.

F & I a type "A" exit light, with an aluminum or painted steel housing and stencil face.

F & I a type "B/DC" exit light, with a plastic polycarbonate housing with stencil on inside of housing, that also has a 12 volt emergency lamp socket.

F & I a type "A/SP" self-powered battery powered exit light, with an aluminum or painted steel housing and stencil face.

F & I a type "B/SP" self-powered battery powered exit light, with a plastic polycarbonate housing with stencil on inside of housing.

F & I a type "A/LS" self-powered luminous source type exit light, with an aluminum or painted steel housing and stencil face .

F & I a type "B/LS" self-powered luminous source type exit light, with a plastic polycarbonate housing with stencil on inside of housing.

F & I an in-line motion occupancy sensor that will cover 500 sq. ft. in an existing single or double gang switchbox.

Rezone fixture and wiring (put the fixture on another circuit) includes wire & flex condiut up to 20 lf(One to Four)

Rezone fixture and wiring (put the fixture on another circuit) includes wire & flex condiut up to 20 lf(Over five)

Install Government Furnished (GFE) fluorescent tube lighting fixture, includes wire & flex condiut up to 20 lf

F & I energy efficient exit light

F & I emergency light

New 1'X4' 2 lamp recessed parabolic light fixture Lithonia #PM3GB2328- LDGEB10LP or equal

F & I Sodium Vapor Lights 250 W, Less than 5

F & ISodium Vapor Lights 250 W, More than 5

F & I Incandescent can lights:

- with standard trim

Option Period 1

Option Period 2

Option Period 2

Option Period 3

Unit Issue

- with eyeball trim

F&I LED Fixture one tube fixture

F&I Parking Garage LED light fixture

SUBTOTAL OF LINE ITEMS:

TOTAL EVALUATED PRICE