This solicitation will result in the awarding of a multiple Indefinite Delivery, Indefinite Quantity (IDIQ) contracts; however, the Government reserves the right to award a single contract if deemed necessary and in its best interest to the government for repair, alteration, and maintenance construction services at the Department of Labor (DOL) main headquarters building located at the Frances Perkins Building (FPB) 200 Constitution Ave. N.W., Washington DC 20210 and surrounding National Capital Region (NCR) DOL lease spaces. The applicable NAICS code for this contract is 236220

(Commercial and Institutional Building Construction).

MINIMUM GUARANTEE

The Government’s only obligation is the Guaranteed Minimum Quantity of Service for the Base Period under the contract. The minimum quantity is

$2,000.00 of delivery orders for the base year contract. PLEASE NOTE: GUARANTEED TASKINGS WILL ONLY BE ISSUED FOR BASE

YEAR CONTRACTS IN THE AMOUNT OF $2,000.00 TO BE ESTABLISHED BEFORE THE LAST DAY OF THE BASE YEAR.

CONTRACT MINIMUM/MAXIMUM QUANTITY AND CONTRACT VALUE

The minimum quantity and contract value for all orders issued against this contract shall not be less than the minimum quantity and contract value stated in the following table. The maximum quantity and contract value for all orders issued against this contract shall not exceed the maximum quantity and contract value stated in the following table.

MINIMUM

QUANTITY

MINIMUM

AMOUNT

MAXIMUM

QUANTITY

MAXIMUM

AMOUNT

$2,000.00 $1,500,000.00

Resulting task orders under this IDIQ contract will have a minimum order amount of $2,000.00 and will not exceed a maximum order amount of

$1,500,000.00. The resulting IDIQ contract has a minimum guarantee of $100,000.00 for full term of the contract.

Included with award will be the offerors supplemental price schedule, which includes Firm Fixed Priced (FFP) rates for specific disciplines and work items. Any item that is not included in this schedule may be negotiated at the task order level.

Section B - Supplies or Services/Prices

Line Item

No.

Base Period

Option

Period 1

Period 2

Period 3

Period 4

Option Period 4

Description of Work

Unit of Issue

QTY*

Unit Price

Extended

Price

Extended Price

GENERAL CONDITIONS

Scope Clarification and assistance

MH

Common Building Laborer

Electrician

Glazer

HVAC Mechanic

Painter

Paper Hanger

Plasterer

Tile Layer

Plumber

Carpenter (may include systems furniture installers)

Sheet Metal Mechanic (HVAC Duct Work)

Mason

Unskilled Laborers

Carpet Installer/Repairs

Concrete Finisher

Sprinkler Installer

Systems/Modular Furniture Installer

Certified Asbestos Worker

Certified Lead Base Paint Removal

Certified IT equipment/cabling installer

Certified cctv/audio-visual equipment installer

DEMOLITION - Including incidental repairs and Disposal of material-25% non-standard work hours rate applied to demolition items involving only labor

Demo Concrete up to 6" thick, Hydraulic hammer

- mesh reinforced (slab)

SY

- Rod reinforced (slab)

Remove Existing Door and Frame

- from drywall

EA

- from masonry

Remove door only up to 3' x 7' including Hardware

Remove and reinstall door w/ hardware

Remove Lockset from existing Door

Remove door stop from wall or floor

Remove metal stud and drywall partition

SF

Remove metal stud and plaster partition

Remove masonry and plaster partition cu ft

Remove drywall from existing wood or metal studs

Remove Wire mesh above suspended ceiling

Demo partition drywall Security w/ flattened exp metal

Remove chair rail, patch drywall or plaster as required

LF

Demo wainscoting

Demo railings and balusters

Demo Cabinets Wood or Metal

Demo Countertops

Demo lath and plaster up to 3" thick

Remove Wall covering Vinyl or Fabric (includes necessary wall repairs)

Remove bank type partition (unit includes post to post)

Remove Accoustical Ceiling Tile:

- including grid systems

- excluding grid system

Remove Carpet:

- glued down

- tacked down

Remove Carpet Pad:

- glued down

- tacked down

Remove resilient flooring (tile or sheet goods)

Remove existing cove base, 4 in. or 6 in.

Remove Baseboard up to 8" to include shoe molding

Remove Shoe Molding

Remove abandoned outlets and thermostats

Remove ductwork, galvanized, includes insulation and hangers

LB

Remove condensing unit, up to 5 Tons, includes reclaiming and recycling of refrigerant.

Demo Lavatory any type plus 10' of pipe

Demo sink any type including 10' of pipe

Demo water closet any type including 10' of pipe

Remove and reset fixtures

Remove Urinals:

- wall mounted

- floor mounted

Demo Water Fountain:

- floor mounted

- wall mounted

Demo Piping, metal, with or without insulation:

- up to 2" diameter

- over 2" up to 4" diameter

- over 4" up to 8" diameter

Remove sprinkler head and piping up to 3'

Remove Sprinkler Piping - up to 12' above floor

- 1/2" through 2" diameter

- 2-1/2" through 4" diameter

Demo Water Heater up to 50 gals

Demo Toilet Partitions

- Slate or Marble ( incl. one wall and one door)

- Hollow Metal or Solid Surface/Phenolic ( incl. one wall and one door)

Remove Ceramic Tile (Walls and Floors) any size tile:

- Thin set

- Mud set

DEMOLITION - All items remain the property of the government.

Remove snap switch and wiring (F & I blank cover)

Remove duplex receptacles and wiring :

from wall (F & I blank cover) from floor duct (F & I cap and plug with sheet metal plate approved by

Building Manager, approximately 3" x 5")

Remove double duplex receptacles and wiring :

Remove telephone outlet and conduit :

Remove conduit or wire mold (500,700,1500) up to 1-1/4" conduit, including conductors, back to origin

10 LF

Remove conduit 1-1/2" to 4", including conductors, back to origin

10 LF

Remove tele-power pole and wiring

Remove voice communication box

Demo transformer, oil filled or dry

- 10 to 15 kva 1 phase

- 30 to 45 kva 1 phase

- 3 to 15 kva 3 phase

- 25 to 30 kva 3 phase

- 45 kva 3 phase

Demo safety switches 250 or 600 volts, includes disconnecting wire, & pipe terminations:

- 30 amp

- 60 amp

- 100 amp

Remove fluorescent fixture and wiring :

- maximum 4 ft. long

- maximum 8 ft. long

Demo Panel Board up to 5 wire 277 volt 125 amp incl. breakers pipe terminations, and wire connects

Demo Panel Board up to 5 wire 480 volt 200 amp incl. breakers pipe terminations, and wire connects

Remove conduit or wire mold, including conductors, back to origin

- Wiremold raceway 500, 700, or 1500 and/or conduit up to 1-1/4"

- Conduit 1-1/2" to 4"

Demo Wire, includs all wires in conduit

- #12 or #10

- #6 or #8

- #3 or #4

- 1/0 or 2/0

- 3/0 or 4/0

- 250, 300, or 350 MCM

- 400 or 500 MCM

Demo Wiremold raceway / conduit including conduit fittings and hangers

- Wiremold raceway 500, 700, or 1500 and/or conduit up to 1 "

- Wiremold raceway 3000 or 4000 and/or conduit larger than 1" up 2"

- Conduit larger than 2" up to 4"

Demo armored cable:

- #14, 2 or 3 wire

- #12, 2 or 3 wire

- #10, 2 or 3 wire

Demo Coaxial Cable including connectors

Demo Telephone/Computer cable including connectors

Remove incandescent fixture and wiring includes wire & flex condiut up to 20 lf

Remove exit light (F & I blank cover, if required)

RELOCATION - Includes maximum 50 ft. change in length of conduit and conductors

Relocate snap switch and wiring (F & I blank cover), up to 3 gang switch

Relocate duplex receptacles and wiring :

- from wall (F & I blank cover)

- from floor duct (F & I cap and plug with sheetmetal plate approved by

Relocate double duplex receptacles and wiring

Relocate telephone outlet box within limits of existing wiring (does not include connection or disconnection of service) :

Relocate tele-power pole, exclude. Conduit run & hookup if existing connection

Relocate voice communication box

Relocate (shift) light fixture in suspended ceiling (no elec disconnect)

Relocate fluorescent fixture and wiring (includes all work, conduit & wiring, max

10' relocation)

- stem, chain or pendent mounted

- recess mounted (lay-in)

- surface mounted

Relocate exit light (F & I blank cover, if required)

Relocate emergency light

Relocate incandescent fixture and wiring includes wire & flex condiut up to 20 lf

CUTTING AND PATCHING

Cut bottom of door to allow carpet installation:

- metal door

- wood door

Cut new opening for door or window in existing partition, includes finishing to match adjacent surfaces :

- Metal Stud and drywall

- Plaster (lath)

- Masonry / CMU (Straight Cut)

Concrete Core -drill up to 12 in. deep :

- Up to 4 in. diameter

- Cost added per inch for over 12" deep

Inch

Cut and chip new hole into existing floor duct for telephone or electrical installation

Excavate/Trench in existing concrete for utilities by hand up to 12" wide

CY

Saw cut Concrete per inch of depth

Patch underlayment for uneven flooring

Install concrete , includes properly sized WWF or Rebar:

- up to 4" thick

- over 4" and up to 6" thick

- over 6" and up to 8" thick

MASONRY

F & I masonry partition 4 in. CMU, w/struck joints without surface finish

F & I masonry partition 8 in. CMU, w/struck joints without surface finish

F & I Plaster finish on concrete block partition , per side

Repair Subfloor, Masonry, where damaged from walls or object removal.

F & I Brick masonry walls veneer 4" thick

Reinforcing for masonry walls

Parging of existing masonry or concrete walls

Stucco on Masonry

METALS

Expanded metal, steel, 9 gauge existing studs to secure with tamper proof screws, minimum 12 in. on center

Expanded metal, steel, 11 gauge existing studs to secure with tamper proof screws, minimum 12 in. on center

Same as 5.1 except from top of ceiling high wall to underside of next floor

Same as 5.2 except from top of ceiling high wall to underside of next floor

Furnish and Install Handrails - 2 Rails

- Wood

- Steel

- Aluminum

Install chain link fence up to 10 ft high, 9 gage with top and bottom rails with 2" (+/-) poles on 10" centers (+/-)

Fence Gate 3' wide for above fence with associated posts and hardware

FINISH CARPENTRY - All bookcases shall be 1 in. birch plywood shelves with solid hardwood nosing, 1/2 in. birch plywood backing, 2 -1/4" solid birch face trim with recessed standard and 4" toe kick plate, sections not to exceed 3 ft. long and 9 feet high with 5 shelves , 16 in. deep.

Bookcases shall be painted 2 coats or stained and coated with 2 coats of polyurethane.

F & I custom bookcase (face equals - width x height)

SF of face

Refinish woodwork - strip, stain and clear finish:

- frames, chair rail, cove base and thresholds up to 8" wide

- doors, walls, ceilings, etc.

Strip, sand and apply 2 coats of polyurethane finish to window ledge

Refinish woodwork - strip and varnish :

- frames, chair rail, cove base and thresholds up to 8" wide

- doors, walls, ceilings, etc. per side

F & I, 1x6 Pine Board for window and door trim

F & I, Clamshell and colonial molding around window and doors

F & I, Hardwood Custom Base Cabinets (A.W.I. Custom Grade) finished top and bottom - Face frame - stain grade birch, oak, or maple

F & I, Hardwood Custom Wall Cabinets (A.W.I. Custom Grade) finished top and bottom - Face frame - stain grade birch, oak, or maple

F & I, Non-Custom Base Cabinets, hardwood, natural finish or paint grade, finished top and bottom

F & I, Non-Custom Wall Cabinets, hardwood, natural finish or paint grade, finished top and bottom

F & I Countertop, Laminate, 24" wide with back and side splash

F & I, Plywood Backboard (4' x 8 'x 3/4")

F&I Countertop, Solidsurface, 24” with back and side splash

Stain Wood Trim and two coats of poly

Stain Doors and Frames w/ two coats of poly, each side

F & I, Parque Flooring-Medium Grade

Blocking in wall (Treated with fire resistant paint)

Furnish and Install Threshold

- Marble - Government Furnished Material

- Wood

INSULATION

F & I mineral fiber sound insulation, 3 1/2 in. thickness :

- unfaced

- foil faced

- Kraft paper faced

F & I Insulation Fiberglass walls, 3-1/2 in. thickness:

- unfaced

- foil faced

- Kraft faced

F & I Insulation Mineral Fiber Batts ceiling, Kraft faced 6" thick R19

Furnish and Install Acrylic Latex Caulk Cartridge type

- 1/4" x 1/2"

- 3/4" x 3/4"

- 1" x 1"

F & I Caulk and Sealant, Polysulfide, 2 parts, in place to make weather tight

Spray on Fire proofing

Pipe Insulation

1 inch

1.25 inch

1.5 inch

2inch

DOORS AND FRAMES

Contractor shall F & I silencers, hinges, and door stops. Doors and frames shall be primed and painted or polyurethane 2 coats. Door leaves not to exceed 3 ft. x

7 ft.

The following items are for installation (labor) only. If materials are required, i.e., not government furnished or reused from demo use other line items.

Install door and frame (Including necessary stud work for proper support.)

- drywall or plaster (3' x 7' Maximum size)

- masonry (4, 6, or 8 in.) (3' x 7' Maximum size)

- Drywall or plaster, double door (6' x 7' Maximum size)

- Masonry (4, 6, or 8 in.) double door (6' x 7' Maximum size)

- Install Door

F & I Metal Frame, single Door, B label (Including necessary stud work for proper support)

F & I Metal Frame, double door, B label (Including necessary stud work for proper support)

F & I hollow core interior wood door natural finish or paint-grade door (3' x 7' max size)

- Birch Face

- Oak Face

- Cherry Face

- Walnut Face

F & I Solid core wood door, B label, natural finish or paint-grade door (3' x 7' max size)

- Birch Face

- Oak Face

- Cherry Face

- Walnut Face

F & I hollow metal door, B label

F & I Oak Pocket Door (3'x7') include trim

F & I Wood grain Laminated accordian doors

F & I Hollow core bi-fold birch finished doors

F & I Louver Pine 4' x 6'8" bifold doors

Additional Drywall repairs and finishes when inserting doors

HARDWARE

F & I door stop - floor, wall, or door mounted.

F & I door closer (match building standard)

F & I Heavy Duty door closer w/ hold open feature

F & I Kick Plates 12" x 36"

- Stainless steel, Medium duty commercial grade

- Bronze, Medium duty commercial grade

- Brass, Medium duty commercial grade

F & I Push Plate and Door Pull (4" x 16")

- Stainless Steel, Medium duty commercial grade

- Bronze, Medium duty commercial grade

- Brass, Medium duty commercial grade

F & I metal louver in door (24" x 24" max.), includes cut opening

F & I Lite Kit (7"x22") in wood door

F & I Stainless Steel Latch Guard

F & I Big Eye (wide view peep hole)

F & I Heavy duty pinned Security hinges (set of three)

- Stainless Steel

- Brass

F & I Heavy Duty premium hinges, Brass

F & I Electric door release w/ release Button

F & I Sound attenuating door seals (door frame and threshold)

- Stainless or Brass

F & I lockset matching building standard (Kwickset, Russwin, Sargent, Schlage, Yale, or equivalent) private with 2 keys on or off building master with replaceable cylinder; (Federal Bldg. Only)

F & I cylindrical passage

F & I lockset with two keys :

- deadbolt, key on key

- deadbolt, key on thumb turn

Furnish extra keys in conjunction with new lockset installation

Install government furnished lockset (labor only)

F & I keyless push button (5 button cypher type) deadbolt and night latch at least 1 in. throw, simplex series 900 type

F & I keyless push button (5 button cypher type) lock set with deadbolt and night latch at least 1 in throw with key override standard access control w/lever simplex type, simplex series 7000 type

F & I Electric Door Release low voltage incl. Transformer low voltage 18 ga wiring and push button

F & I PIV enabled card readers

F&I Low Energy Single Door Automatic Opener

PREMIUM ITEMS

Premium Closers, Bronze finish (furnish only)

Premium Deadlock, Bronze finish (furnish only)

Premium Latchset, Bronze finish (furnish only)

Premium Locks, Bronze finish (furnish only)

Premium Privacy Locks, Bronze finish (furnish only)

F&I Medeco interchangeable core, motise cylinders, with 2 keys on/off bldg.

master to be used with heavy duty mortise lockset shown below, finish to match standard

F&I CD-X09 High Security Lock

F & I Single action door release for High Security Locked doors, LKM-7000 or equal

F&I heavy duty mortise lockset, lever handle

- Stainless Steel finish

- US3 bright Brass

- US10 bright Bronze

Best Lock Sets 93k Series (cylindrical) - 626 finish

Add for Brass

Best Lock Set 35H Series (Mortise)

Add for Brass

F & I Flush Bolts top and bottom - 626 finish

PR

Panic Device ( Fire Rated) - Surface Mounted

- 99 E.O. Von Duprin 26D Finish

- 99 E.O. Von Duprin US3 Finish

- 9927 E.O. Von Duprin 26D Finish

- 9927 E.O. Von Duprin US3 Finish

STANDARD PARTITIONS - **All line items include full floor-to-ceiling height (up to 12 ft.) partition; including 4" or 6" either existing integral metal base or new cove base, all required trim and molding, and painting of all non-vinyl surfaces, including priming & 2 coats of paint on all unpainted surfaces and 2 coats of paint or polyurethane on all unfinished surfaces and two coats on all previously painted surfaces

**All partitions over 12 ft will be increased by 1.5

F & I metal stud and drywall, 5/8 in. or 1/2 in. drywall both sides

$0.00

F & I standard partition, metal stud, 5/8 or 1/2 in. drywall one side only

F & I metal stud and plaster including wire lathe (2 sides)

F & I metal stud and 5/8" or 1/2" drywall bulkhead, minimum 6" - maximum

10"

F & I Zip Bead on top or edge of walls

Add for Wall built with Load bearing 16 gage metal studs

Add for hat channel installed on existing C.M.U. wall in lieu of metal stud framing

F & I drywall on existing wood or metal studs

F & I window in drywall partition, safety glass, not to exceed 6 ft. wide by 5 ft.

high (does not include cutting the hole) :

- wood frame

- metal frame

F & I wood chair rail - 2 piece

F & I Oak Chair rail - One piece.

F & I Oak Plinth block - match building standard

F & I Oak Door Casings - Match Building Standard

F & I 8" Oak Baseboard

F & I Oak Shoe Molding

FLOOR COVERINGS

F & I 4 in. or 6 in. resilient cove base with molded corners

F & I wood, metal or vinyl trim up to 6 in. wide, enamel, varnish or stain

F & I approved vinyl composite tile (VCT) (12 in. x 12 in. x 1/8 in.)

F & I Anti-static vinyl tile

Clean (strip /seal) and Apply two (2) coats of wax to new VCT

Handling of Delivered Carpeting (tiles or rolled)

Install gov't furnished carpet squares, contractor supplied adhesive per manufacturer

Install gov't furnished carpet squares by jacking up of furniture, contractor supplied adhesive per manufacturer

Install gov't furnished carpet roll goods :

- glue down (contractor supplied adhesive per manufacturer)

- tack down over existing pad

F & I Carpet pad (tacked or glue down):

- 1/4 in. minimum, felt type

- 1/4 in. minimum, commercial foam

F & I carpet transition strip

Repair existing carpet

Patch carpet where partitions were removed up to 5 in. wide (gov't furnished carpet)

F & I Ceramic Tile

- thin set floors and walls

- mud set floors and walls

Seal Concrete Floor

Install epoxy floor

F&I install terrazzo style tile

CEILING SYSTEMS - Acoustical Ceiling Tile (ACT)

F & I New 2' x 2' ACT in existing grid (includes removal of existing tile)

- 2' x 2' ACT

- 2' x 4' ACT

- 2' x 5' ACT

F & I 2' x 2' Premium (revealed edge) ACT in existing grid (includes removal of existing tile)

F & I New ACT & Grid System (includes removal of existing)

- 2' x 2' ACT

- 2' x 4' ACT

- 2' x 5' ACT

F & I 2'x 2' or 2' x 4' Premium (revealed edge) ACT & Grid System (metric or standard)

F & I spline ceiling tile - 1' x 1' - New

F & I spline ceiling tile - 1' x 1' - Remove & Reinstall

Install government furnished ceiling tiles in existing grid system

(such as 1 ft. X 5 ft., 2 ft. X 5 ft., 2 ft. X 2 ft., 2 ft. X 4 ft., 1 ft. X 1 ft., etc.)

Cut Ceiling tile and grid system to facilitate installation of wall partition above ceiling height, includes re-installation of ceiling system to new wall partition on both sides

Repair ceiling tile and grid system where partition was removed

PAINTING

Paint existing surfaces with two coats. The unit price shall be increased by 20% for painting over 12 ft. high. Painted materials include plaster, drywall, metal, wood, concrete and masonry. Includes moving furniture. Area shall be

Provide and apply paint :

- finish coats of paint, less than 1000 square feet

SQ FT

- finish coats of paint - using government furnished paint

- finish coats of paint, more than 1000 square feet

- Additional 2 coats due to unusual circumstances

Special Items :

- Paint door leaf, 3 ft x 7 ft maximum size, one side

- Paint door leaf, 3 ft x 7 ft maximum size, both sides

- Paint doors and panels, dimensions other than standard

- Paint door frame, one side

- Paint door frame, two sides

- Paint door frame. Two side for 6' x7'

- Paint windows, mullions and trim, enamel or varnish

SF of open

- Paint wood, vinyl, or metal base up to 8 in. high, enamel or varnish

- Repair damaged or deteriorated plaster, less than 25 sq. YD. (includes removal of all damaged material and rebuild of wall; max 3 coats of plaster; 3 coats of paint)

- Repair damaged or deteriorated plaster, more than 25 sq. YD. (includes removal of all damaged material and rebuild of wall; max 3 coats of plaster; 3 coats of paint)

- Paint handrails (up to 3 rail systems)

- Paint stair risers (up to 6 feet wide X 1 foot high, 2 coats)

- Sand and spackle interior walls (above normal preparation)

- Thin coat of Plaster to smooth out walls Including sealing before and after

- Clean prep patch holes and paint existing ceiling grid system

WALL COVERINGS

F & I vinyl wall covering complying with Federal Specification CCC-W-408A :

- Heavy Weight (25-30 oz/SF) - New GWB Walls, Existing GWB Walls, &

Existing Plaster Walls

- Medium Weight (20-24 oz/SF) - New GWB Walls, Existing GWB Walls, &

Existing Plaster Walls

- Light Weight (12-15 oz/SF) - New GWB Walls, Existing GWB Walls, & Existing

Plaster Walls

Install government furnished vinyl wall covering (includes normal wall preparation)

Install government furnished fabric wall covering (includes normal wall prep)

F & I Floor to ceiling heavy Duty wall corner guards, vinyl

PARKING GARAGE / LOT PAINTING - Includes all necessary Cleaning & Preparation of

Surface

Repainting of existing parking lines

Parking Space Markings (per character), up to 12"

Parking Space Markings (per character), larger than 12"

Parking Space Handicap Markings

Less than 20 parking spaces, mobilization cost

Remarking caution lines in warehouse, loading dock, storage areas by hand w/ tape

MISCELLANEOUS MATERIALS

Coaxial, BNC, quick disconnect or screw on with chrome or gold plated center pin

Multi-conductor type, up to 24 pair, terminated

F & I Toilet Seat cover Dispenser, S/S Surface mounted

F & I Toilet Tissue Dispenser, s/s single roll surface mounted

F & I Toilet Tissue Dispenser, s/s double roll surface mounted

F & I Towel Bar s/s up to 30" long

F & I Towel Dispenser s/s surface mounted

F & I Towel Dispenser s/s flush mounted

F & I Towel Dispenser and Waste Receptacle, recessed 18 gal capacity

F & I Soap dispenser, Chrome , liquid, surface mounted

F & I Soap dispenser, Chrome , liquid, countertop mounted

F & I Electric Hand Dryer, Medium grade - DOES NOT INCLUDE ELECTRIC

CIRCUIT

F & I Shower Rod, hooks and Curtain

F & I Stainless Steel Channel Frame Mirror (18" x 30")

F & I Single towel dispensing, centerpull towel dispenser

F & I Soap Dispenser, plastic, liquid, surface mounted

WASTE AND VENT LINES (DWV) FURNISH AND INSTALL (including hangers @ 10" on center)

F & I DWV 1-1/2" Cast Iron no-hub

F & I DWV 2" Cast Iron no-hub

F & I DWV 3" Cast Iron no-hub

F & I DWV 4" Cast Iron no-hub

F & I Fiberglass Reinforced Panels (FRP) for bathrooms

F & I Fiberglass shower 36"x36"

PLUMBING FIXTURES FURNISH AND INSTALL

System includes rough-in supply waste and vent and shut off valves for connection to existing supply branches and mains, and all trim

F & I Water Closet, Wall mounted, Vitreous China, Bowl only with Flush Valve

F & I Water Closet, Floor Mounted, Vitreous China, Bowl only with Flush Valve

F & I Urinal - Wall mounted, Vitreous China, Bowl only with Flush Valve trim and hanger

F & I Automatic Flush sensor and operator for Urinal & water closets

F & I Lavatory, Porcelain, Enamel . on Cast Iron, wall hung with trim and concealed arm support size 20" x 18"

F & I Lavatory Porcelain Enamel on Cast Iron SB w/trim incl. plastic Laminated base cabinet and top w/ back splash door and Hardware up to 36" W. x 30" H w/ slope base for Handicap w soap dispenser hole

F & I s/s nominal size 25" x 22" sink, 6 to 8 inches deep.

F & I Sensor Faucet push front self closing

F & I Gooseneck lavatory Faucet w/ wrist handles

F & I Single Lever lavatory faucet

F & I Elongated Bowl, Direct-fed siphon jet flush action, gravity assisted flushing system floor mounted toilet with commercial grade seat

F & I Wall Mounted, Low Consumption, Siphon jet action, extended side Urinal

MECHANICAL

Relocate pneumatic thermostat

Relocate electric thermostat

F & I Thermostat, Pneumatic/Electric incl. up to 50 of wire / tubing

F & I Master unit with thermostat

F & I Slave unit

Install Government Furnished (GFE) moduline variable air volume box

Add sprinkler head up to 10 ft. (includes government furnished ceiling tile)

Relocate sprinkler head up to 10 ft. (includes government furnished ceiling tile)

F & I concealed sprinkle head

F & I Hinged sprinkle head escushin

Remove flexible ductwork. Cap abandoned opening with ductwork for an airtight seal up to 30'

F&I 1" thick glass fiber blanket duct insulation with vapor barrier

F&I pneumatic tubing between VAV boxes

Convert slave terminal box to a master box with new thermostat, filter, and regulator

Relocate diffuser/grille withing limits of flex duct

F&I 12"X12" return air grilles in ceiling. Provide 1/2" x 1" x 1" aluminum lattice grilles and frame

F & I Register/Damper, 2X2 Lay in, up to 12" round

F&I 2' x 2' return air grilles in ceiling, does NOT include any ductwork

F & I 4" flexible, non insulated duct

F&I 6" round flexible, insulated, supply air, ductwork, 1" thick, 3/4" lb. density.

F & I Flex Duct insulated, over 6" and up to 12" dia

F & I Rigid Rectagular Duct, galvanized steel (includes fabrication, installation, fittings, tap in collars, joints, transitional fittings, allowance for flexible connections, supports, 1" thick insulation, sealing, leak testing) to commercial

- Under 2,000 LBS

- Over 2,000 LBS

F & I Rigid Round / Flat Oval Duct, galvanized steel (includes fabrication, installation, fittings, tap in collars, joints, transitional fittings, allowance for flexible connections, supports, 1" thick insulation, sealing, leak testing) to

- 4"

- 6"

- 8"

- 10"

- 12"

VAV box-inspect, clean, calibrate & report components in need of repair or replacement

Fan Coil Unit - inspect, clean, calibrate & report components in need of repair or replacement

F & I Access panel, Hinged, lockable

- 12" x 12"

- 22" x 22"

F & I exhaust Fan 110cfm

F & I Interior Mounted exhaust fan 700cfm

Relocate, existing F/A accessory, includes up to 50 LF of new EMT and wire

- Fire Bell

- Pull Station

- Strobe Light

F & I New F/A accessory w/ up to 50 EMT and wire

- Fire Bell

- Pull Station

- Strobe Light

DOMESTIC WATER SUPPLY PIPING FURNISH AND INSTALL (including hangers & insulation)

F & I Copper Tubing type 'L'

- 1/2 inch

- 3/4 inch

- 1 inch

2 inch

VALVES-FURNISH AND INSTALL BRONZE OR COPPER

Valve, Ball or Gate

2 inch

Check Valve, sweat

F & I Shower Valves

HVAC - DUCT WORK

3 ton Computer Room Air Conditioninf Unit

2 Diffusers (200 to 300 CFM ea)

1 Return Grille (Sized for less than 600 FPM return velocity)

Ductwork (Approximately 20LF)

Insulation

Hangers

5 ton Computer Room Air Conditioninf Unit

4 Diffusers (200 to 300 CFM ea)

1 Return Grille (Sized for less than 600 FPM return velocity)

Ductwork (Approximately 30LF)

10 ton Computer Room Air Conditioninf Unit

6 Diffusers (200 to 300 CFM ea)

2 Return Grille (Sized for less than 600 FPM return velocity)

Ductwork (Approximately 40LF)

15 ton Computer Room Air Conditioninf Unit

6 Diffusers (200 to 300 CFM ea)

2 Return Grille (Sized for less than 600 FPM return velocity)

Ductwork (Approximately 40LF)

5 Ton Split System

6 Diffusers (200 to 400 CFM ea)

4 Return Grille (Sized for less than 600 FPM return velocity)

Ductwork (Approximately 60LF)

F & I Emergency Drain Pan under AHU in Ceiling up to 50'

F & I one electric duct heater up to 10 kw

F & I 2" steel pipe

F & I 3/4" Copper condensate line

Additional Line Set

Duct take off with damper

ELECTRICAL WORK

The follow Items are for Installation (labor) only Gov't Furnish If material are required I.e. not Gov't furnished, additional line items are necessary

Install Gov't Furnished Coaxial Cable in existing Floor duct, up to 25 conductors per cable and or 2 O.D. not incl. Terminations

Install Gov't Furnished Coaxial Cable above suspended ceiling up to 25 conductors per cable and or 2 O.D. not incl. Terminations

Install Gov't Furnished Connectors / per conductor 24 pin multi-conductor type for cable pull

NEW WORK - Includes maximum 50 ft. length of conduit and conductors.

Does not include panel connection.

F & I snap switch and wiring :

- single pole

- 3-way

- 4-way

F & I Switch Wall Dimmer 120/277 V 20 min Incandescent

F & I Switch Wall Dimmer 120/277 V 20 min florescent

F & I duplex receptacle and wiring :

- in wall

- in floor duct (existing hole)

F & I GFCI receptacle and wiring:

- in wall (new construction)

- in wall (existing wall)

F & I double duplex receptacle and wiring :

- in floor duct, monument type (existing hole)

F & I 220 volt dedicated receptacle and wire

F & I 120 volt, 20 amp dedicated receptacle and wire

F & I 120 volt, 20 amp dedicated isolated ground receptacle and wire

F & I dedicated circuit and junction box for systems furniture connection.

Includes hook-up of systems furniture "whip" or "pigtail"; (Government or

Agency furnished "whip")

F & I blank cover for telephone or electrical outlet :

- in floor duct (F&I cap & plug w/sheetmetal plate approved by Bldg. Manager., approx. 3"x5")

F & I telephone or computer outlet box & 10lf conduit in room (new construction)

- new construction

- fished into existing wall

- in floor duct (existing hole)

F & I telephone or computer wiring, terminated at both ends, plenum rated

- Cat 5 or 5e cable

- Cat 6 cable

F & I conduit (EMT or wiremold) per ft. lengths beyond initial 50 ft. length :

- 3/4 in. conduit or #500 wiremold

- 1 in. conduit or #700 wiremold

- 1 1/4 in. conduit

- 1 1/2 in. conduit or #2100 wiremold

- 2 in. conduit or #3000 wiremold

- 2 1/2 in conduit

- 3 in. conduit

- 4 in. conduit

Install conduit fittings: LB, LL, or LR with covers :

- 3/4 in. diameter

- 1 in. diameter

- 1 1/2 in. diameter

- 2 in. diameter

- 3 in. diameter

- 4 in. diameter

F & I conduit, RSC (Rigid Galvanized Steel) per ft. lengths beyond initial 50 ft.

length :

- 1/2 in. conduit

- 3/4 in. conduit or #500 wiremold

- 1 in. conduit or #700 wiremold

- 1 1/4 in. conduit

- 1 1/2 in. conduit or #2100 wiremold

- 2 in. conduit or #3000 wiremold

- 3 in. conduit

- 4 in. conduit

RSC (Rigid Galvanized Steel) field bends:

- 1 1/4 in.

- 1 1/2 in.

- 2 in.

F & I RSC (Rigid Galvanized Steel) elbows:

- 1 1/4 in.

- 1 1/2 in.

- 2 in.

- 3 in.

- 4 in.

F & I single conductor :

- # 12

- # 10

- # 8

- # 6

- # 4

- # 3

- # 2

- 1/0

- 2/0

- 3/0

- 4/0 AWG Copper, 600V

- 350 mcm

- 500 mcm

F & I circuit breaker panel, 3 phase, 100 amp, with main breaker or safety switch

- 32 breaker capacity, includes F & I 12 circuit breakers

- 42 breaker capacity, includes F & I 18 circuit breakers

- 200 amp 3 ph panel with 50% breakers installed w/remainder as blanked off spares.

- 400 amp 3 ph panel with 50% breakers installed and remainder blanked off spares.

F & I additional circuit breakers in existing panel, single or double pole :

- up to 30 amps

- 35 to 60 amps

- 65 to 100 amps

F & I additional circuit breakers in existing panel, 3 pole 150 - 200 amp

Tie circuit into circuit breaker (breaker not included)

F & I tele-power pole and wire up to 50 ft. maximum

Install government furnished tele-power pole (Contractor furnished wiring up to 50 ft.)

F & I circuit breaker panel, 1 phase, 3 wire, with main breaker or safety switch :

- 100 amp

- 150 amp

- 200 amp

F & I Electric base board heates including controls (unit mount)

- 4 foot

- 8 foot

Furnish and Install conduit fittings: LB, LL, or LR with covers :

- 3/4 in. diameter

- 1 in. diameter

- 1 1/2 in. diameter

- 2 in. diameter

- 3 in. diameter

- 4 in. diameter

F & I heavy duty fused safety switch or circuit breaker, 3-pole, 600 V

- up to 30 amps

- 35 to 60 amps

- 65 to 100 amps

Fuses 200A, 600V, Cu

ENERGY EFFICIENT LIGHTING - Paragraph numbers refer to Contract

Specification Section 16010.

F & I fluorescent tube lighting fixtures :

F & I 24 in. x 24 in. recessed fluorescent 2 U-Tube fixture with specular parabolic reflectors and electronic ballast (with energy saving 32 watt tubes).

F & I 12 in. x 48 in. recessed fluorescent 1 tube fixture with specular parabolic reflector and electronic ballast (with energy saving 32 watt tube). One ballast

(included) shall be used for 2 or more fixtures, if possible.

F & I 24 in. x 48 in. recessed fluorescent 2 tube fixture with specular parabolic reflectors and electronic ballast (with energy saving 32 watt tubes).

F & I 24 in. x 24 in. surface mounted fluorescent 2 U-tube fixture with specular parabolic reflectors and electronic ballast (with energy saving 32 watt tubes).

F & I 12 in. x 48 in. surface mounted fluorescent 1 tube fixture with specular parabolic reflector and electronic ballast (with energy saving 32 watt tube). One ballast (included) shall be used for 2 or more fixtures, if possible.

F & I 24 in. x 48 in. surface mounted fluorescent 2 tube fixture with specular parabolic reflectors and electronic ballast (with energy saving 32 watt tubes).

F & I a T-8 electronic ballast into an existing fixture. Where a different type of ballast is being replaced, installation includes the installation of new T-8 type lamps in the fixture.

F & I specular parabolic reflector into existing 24 in. x 48 in. fixture. Where the number of fluorescent tubes is decreased, installation includes disconnecting the unneeded ballast's from the power supply and repositioning the tube connectors within the fixture.

F & I specular parabolic reflector into existing 24 in. x 24. in fixture. Where the

F & I specular parabolic reflector into existing 12 in. x 48 in. fixture. Where the

F & I compact fluorescent downlight fixture using PL lamp including reflector and electronic ballast.

F & I tungsten-halogen downlight fixture including reflector and electronic ballast.

F & I a type "A" exit light, with an aluminum or painted steel housing and stencil face.

F & I a type "B/DC" exit light, with a plastic polycarbonate housing with stencil on inside of housing, that also has a 12 volt emergency lamp socket.

F & I a type "A/SP" self-powered battery powered exit light, with an aluminum or painted steel housing and stencil face.

F & I a type "B/SP" self-powered battery powered exit light, with a plastic polycarbonate housing with stencil on inside of housing.

F & I a type "A/LS" self-powered luminous source type exit light, with an aluminum or painted steel housing and stencil face .

F & I a type "B/LS" self-powered luminous source type exit light, with a plastic polycarbonate housing with stencil on inside of housing.

F & I an in-line motion occupancy sensor that will cover 500 sq. ft. in an existing single or double gang switchbox.

Rezone fixture and wiring (put the fixture on another circuit) includes wire & flex condiut up to 20 lf(One to Four)

Rezone fixture and wiring (put the fixture on another circuit) includes wire & flex condiut up to 20 lf(Over five)

Install Government Furnished (GFE) fluorescent tube lighting fixture, includes wire & flex condiut up to 20 lf

F & I energy efficient exit light

F & I emergency light

New 1'X4' 2 lamp recessed parabolic light fixture Lithonia #PM3GB2328-

LDGEB10LP or equal

F & I Sodium Vapor Lights 250 W, Less than 5

F & ISodium Vapor Lights 250 W, More than 5

F & I Incandescent can lights:

- with standard trim

Line Item No.

Unit Issue

- with eyeball trim

F&I LED Fixture one tube fixture

F&I Parking Garage LED light fixture

SUBTOTAL OF LINE ITEMS:

TOTAL EVALUATED PRICE

Section C – Description/Specifications/Statement of Work

C.1 - Project Information

C.1.1 Background: The Department of Labor (DOL) main headquarters building located at the Frances Perkins Building (FPB) 200

Constitution Ave. N.W., Washington DC 20210 and surrounding National Capital Region (NCR) DOL lease spaces. The applicable NAICS code for this contract is 236220 (Commercial and Institutional Building Construction). The work includes the general nature of repair and construction services but is not limited to general office renovation, interior construction and carpentry; infrastructural electrical, plumbing and mechanical systems; building exterior repair, replacement and restoration; interior and exterior lighting; wall partition construction, floor and wall mounted telephone, signal, and power outlets to include the modification of associated conduit, surface mounted raceway, and various under floor duct systems; installation of new and the alteration of existing power panels; carpet and various floor coverings, tile and floor tile replacement; audio / visual installation; wall coverings and painting; signage and labeling; striping, signage and labeling, striping and labeling / identification; door, door frame, and door set hardware installation and automatic / rollup doors; key and lock / card readers installation; window and glazing, fenestration, window / solar / blast films; handrail and guardrail repair replacement and installation; installation of various wall coverings and draperies; network / communications cabling; grid ceiling / acoustic tile and lighting/LED installation and modification; fabric wall and cubicle / systems furniture installation and modification; HVAC installation, modification and repair; installation and modification of existing building fire sprinkler systems; plastering and plaster repair work; sidewalk repair / replacement, asphalt / paving and cold patching, concrete repair / spalling and replacement; masonry, stone and limestone repair / replacement; drain clearing, architectural, drains / storm drainage repair and replacement and clearing; waterproofing / epoxy and non-skid and sealing; miscellaneous drainage structures such as culverts and headwalls; pavers and terrazzo repair and replacement; and other miscellaneous minor civil work items; ornamental fountains; expansion joints, hardscapes relevant to property; roofing systems and repairs; earthwork; demolition; lead, asbestos, and other hazardous material abatement and testing; and other such related work as noted in the scope of work, and which is specifically listed on the task order and job drawings.

C.2 - As required, the contractor(s) shall perform all investigation and design services (or design build services) necessary to provide the

Government a design package for task orders that complete the Statement of Work (SOW), specifications and drawings that describes how the contractor intends on meeting the requirement, including proposed pricing and performance period.

C.3 Description: The scope of services include, but are not limited to the following:

• General Construction Services

• Professional Design and Engineering Services

• Adaptive-reuse of existing facilities to accommodate new functional and space requirements

• Installation of new power distribution systems, and the alteration of existing power distribution systems including but not limited to switchboards, transfer switches, transformers, panels, breakers, feeders and general circuiting

• Removal, installation, and repair for floor finish systems including but not limited to, concrete, ceramic and VCT tile, hard-surfaces, carpet and carpet tile installation

• Interior and exterior painting

• HVAC duct work including installation, modification, and repair. Installation of HVAC related DDC points, BMS low voltage distribution

• Door, door frame, and door hardware-set installation

• Installation of wall finishes systems including window treatments, trim, and molding

• Low-voltage and data communications cable-plant installation and modification

• Installation and modification of ceiling systems and finish materials including suspended ceilings and grid, gypsum, ceiling components including lighting, fire alarm devices, and ceiling mounted equipment

• Installation and modification of fire suppression systems; and fire alarm systems. (these installations and modifications will comply to the

DOL and GSA Standards)

• All services associated with the Design, Construction and Facilities Management Industries including but not limited to all sections of the

Specification Sections

Provide design and/or construction related to, but not limited to:

• Architecture and Design, including development of requirements and space programming, value engineering, constructability, pier-reviews, and A/E oversight

• Professional Engineering Services including Structural, Mechanical, Electrical, Civil, Geotechnical, Blast, Physical Security, and

Information Technology

• Hazardous Material Services including assessment, abatement, encapsulation, disposal, mitigation, and monitoring

• Landscape Architecture, including hard-scape and soft-scape solutions for physical security

• Special Products and Systems, such as elevator, lifts and hoist systems

• Physical and Technical Security design and engineering, security assessments, planning and design

• Interior Design

• Life Safety/fire-protection

• Historic Preservation

All successful IDIQ contractors shall participate in an annual roundtable discussion at no cost to the Government. It shall be planned and facilitated by the DOL Building Management Division, which will be a form of discussion to generate and implement lessons learned into subsequent FY construction programs targeted at improving the DOL construction program. The objectives will include but not limited to increased efficiency, technical accuracy of procurement documentation, and higher quality at less cost. In addition the roundtable discussion is an opportunity for the participants to get together in an informal setting to examine customer relationship management issues as they relate to the implementation of construction initiatives at the DOL facility. The duration of each FY roundtable discussion is anticipated to be one full business day.

Participants will be required to attend the mandatory roundtable discussion that will be held at the DOL facility, and to prepare documentation explaining cause and effect, examples of problematic areas, and to recommend multiple solutions to resolve the issues in subsequent FY programs.

C.4 General Construction Services: Construction work required by the Contractor will involve all trades normally utilized in construction, to include but not limited to, installation and movement of heavy equipment, electrical, plumbing, mechanical, masonry, carpentry, sheet metal, and painting. The Contractor shall manage, administer, supervise and inspect the construction. The coordination and supervision of all work shall be the Contractor's responsibility.

a) Record Drawings

During performance of the work the Contractor shall have on hand and shall maintain a current record of all changes and corrections that deviate from the approved Construction Documents, Submittals, and Scope of Work. The Contractor shall record changes and corrections on the

Construction Documents and shall submit the As-Built Drawings in the form of “red line” drawings in both Hard Copy and AutoCAD Format to the Contracting Officer upon completion of the project. The Government does not guarantee the accuracy of any existing record drawings that it may be appended to the Task Order, Contract or Scope of Work. The Contractor is solely responsible for the verification of all existing conditions and As-Built Drawings issued with the contract.

b) For all Task Orders requiring Construction Documentation including Drawings and Specifications the DOL general

AutoCAD format requirements apply.

Electronic AutoCAD drawing files shall be submitted in the following two formats:

Format-1: Drawing files shall include all externally referenced and base files.

Format-2: Drawing files shall include all externally referenced and base files BOUND into a single electronic file using the “Insert” method (described below). Use XBIND to add individual xref-dependent named objects to the local definition table. There are two methods of binding xrefs to the base drawing. They are “Bind” and “Insert”. Bind alters the definition table names of an xref and attributed blocks within the Xref when it is inserted. Insert does NOT alter the definition table names of an xref and attributed blocks within the Xref when it is inserted. To bind a nested xref, you must also select the parent xref.

The Contractor shall use the “Insert Method” to bind xref files to the base drawing file. It is critical that Xref-dependent named objects and attributed blocks are not changed from their original block name. This shall allow the drawings to be incorporated into an automated facilities management platform as a single file while maintaining the data integrity for Xref dependent objects and attributed blocks. The A/E contractor must use the “Insert Method” for the Format-2 submittal.

All externally referenced (Xref) files shall NOT include a pathname associated with them,

c) Verification of Dimensions

The Contractor shall be responsible for the coordination and accuracy of the work. The Contractor shall field verify all dimensions and advise the

Contracting Officer Representative (COR) of any discrepancies, conflicts, and risk prior to proceeding with any phase of the work. Where exact locations are not given for the positioning of equipment and devices, they shall be positioned to permit easy access for maintenance and for removal and replacement of component parts and shall comply with all codes and ordnances.

i) Physical Data. Data and information furnished or referred to below is for the Contractor’s information. The Government shall not be responsible for any interpretation of or conclusion drawn from the data or information by the Contractor.

ii) Physical Conditions. The indications of physical conditions on the drawings and in the specifications are the result of site investigations.

iii) Inspection of Sites or Buildings. It is the Contractor’s responsibility to ascertain possible conditions at the site, including such things as elevator size and capacity, exiting building materials and components, etc.

iv) Weather Conditions. The Contractor shall have made an investigation of weather conditions, which might occur during the construction period.

v) Standardization. Where two or more items of the same type or class of equipment furnished in this project are required, the units shall be products of the same manufacturer and shall be interchangeable when of the same size, capacity, performance characteristics, and rating. The only exception to this requirement is where the items are interchangeable due to conformance with industry standards (valves, fittings, etc.); they need not be by the same manufacturer. This requirement applies to all manufactured items in the project, which normally require repair or replacement during the life of the equipment.

vi) Existing work shall be cut, drilled, altered, removed or temporarily removed and replaced as necessary for performance of work under this contract. Work that is replaced shall match existing work. Structural members shall not be cut or altered, except where noted on drawings and where alterations to existing structural systems are approved and sealed by a registered practicing Structural Engineer, if there are no engineered changes to structural systems will be vetted by SMEs and approved with authorization by the COR. Work specified as “existing to remaining” but is damaged or defaced during performance of work shall be restored to the condition existing at time of placement of the task order. Work out of alignment when exposed by removal of existing work shall be called to the COR’s attention.

vii) New Work. Unless otherwise noted or specified on the task order new work shall correspond in all respects with that to which it connects, or to similar existing conditions, in materials, workmanship and finish.

d) Coordination with Government Activities

The Contractor in coordination with the COR shall be responsible for the coordination of the work with all state and local government entities regarding EPA, disruption of utilities, traffic, etc.

i) If it becomes necessary to interrupt daily operations of the facility in order to perform the work, the contractor shall submit a detailed “Maintenance of Operations Plan” illustrating in detail the impact of the work on daily operations and how the contractor will phase the work to minimize the impact of the work. The Maintenance of Operations Plan shall be submitted in conjunction with the Project Delivery Schedule (PDS). Permission to disrupt the facility’s daily activities must be approved in writing by the Contracting Officer and the COR seven (7) working days prior to the commencement of the work determined to cause the impact. COR written requests for street closing shall be submitted for approval of the

COR seven (7) working days prior to closing the street.

ii) Temporary interruption of essential and daily operations due to the performance of the work shall be scheduled in consultation with the COR and the Integra