DEN-R Surface Surveillance Systems (ASDE) Inspection Checklist 8.20.2024.pdf
PDF 3 MB Posted
- Solicitation number
- 6973GH-26-R-00069
About this file
This is a Surface Surveillance Systems Inspection Report for an ASDE (Airport Surface Detection Equipment) site located at DEN Remote (Denver) conducted on August 20, 2024. The inspection assesses the physical condition, functionality, and serviceability of site assets including the 90-foot tower, antenna system, and shelter buildings to determine compliance with operational standards and tolerances.
The inspection identified two critical deficiencies requiring immediate attention: the tower painting is in poor condition with 100% of the surface area requiring repainting, and the elevator is non-operational with missing stop plates on the rails, making both the elevator and ladder unsafe for use. A stair tower will be installed to replace the unsafe access. Additionally, moderate deficiencies include the need to replace the broken hydraulic assist for the hatch door, install saddle clamps on the first-level grating, and replace a lock on the equipment shelter door. The assessment also noted issues with the drive system workspace accessibility. The ASDE-3 system includes asset serial numbers for the pedestal assembly (M032) and slipring (210-R02). Lead Technician Mark Hughes (405-620-6976) and SSC Manager Norm Pratt (303-342-1415) are the primary contacts. The PMO's objective is to extend antenna life up to 10 years and tower life up to 20 years, with this inspection providing critical input for maintenance planning and resource allocation.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Surface Surveillance Systems Inspection Report 1
Surface Surveillance Systems Inspection Report (ASDE)
Site Name: DEN Remote Survey Date: 08/20/2024
Radar Information
System ASDE-3
Site ID DEN Remote
Tower Height 90’
Shipping Address 8500 Pena BLVD. Denver Co. 82049
Physical Site Address 8500 Pena BLVD. Denver Co. 82049
Latitude 39.86792
Longitude -104.6551
Asset Serial Numbers:
Detection Equipment
Set
Pedestal Assembly M032
Antenna Assembly
Drive Motor
Slipring 210-R02
Rotary Joint
Antenna
PERSONNEL INFORMATION
Lead Technician / Engineer
Mark Hughes Phone # 405-620-6976 E-mail Mark.hughes@faa.gov
Assessment Technician
Phone # E-mail
Site Escort Phone # E-mail
SSC Manager Norm Pratt Phone # 303-342-1415 E-mail Norm.pratt@faa.gov
Surface Surveillance Systems Assessment Report 2
Introduction
The PMO desires to extend the life of ASDE antennas up to 10 years until a new antenna is approved and installed, and extend the life of the ASDE towers up to 20 years to support the new antennas.
This ASDE inspection project is an input to the PMO to aid their decision-making regarding what tasks need to be performed at each site to meet these desires.
The inspection project includes a hands-on inspection of the physical condition and functionality or serviceability of site assets including the tower, antenna system, and shelter buildings to determine whether the standards and tolerances for operations are being maintained. When the existing condition, functionality or serviceability are determined to be out of required standards and tolerances a corrective action has been provided to facilitate repairs.
Recommendations
Tower paint is in poor condition. Entire tower should be painted.
Install saddle clamps on grating on first level.
Replace broken hydraulic assist for hatch door.
Elevator is unusable and stop plates were not found on elevator rails. Elevator and ladder are both unsafe to use. Stair tower will be installed alongside the remote tower.
Surface Surveillance Systems Assessment Report 3
Assessment Deficiency Report
• Green: Minor issues noted due to non-compliance with a current standard.
• Yellow: Moderate issues identified that should be corrected when possible, but is not an immediate concern.
• Red: Critical issues identified that may affect personnel safety, cause a system outage, or damage to equipment. These issues require immediate attention.
Critical Moderate Minor No Issues Not Inspected
1. Tower ☐ ☒ ☐ ☐ ☐
2. Concrete Foundation ☐ ☐ ☐ ☒ ☐
3. Tower Painting and Galvanization ☒ ☐ ☐ ☐ ☐
4. Shelters ☐ ☐ ☐ ☒ ☐
5. Waveguide ☐ ☐ ☐ ☒ ☐
6. Lightning Protection System ☐ ☐ ☐ ☒ ☐
7. Main Bearing / Drive System ☐ ☐ ☐ ☒ ☐
8. Rotary Joint ☐ ☐ ☐ ☒ ☐
9. Antenna Junction Box Enclosures ☐ ☐ ☐ ☒ ☐
10. Antenna / Rotodome / Radome ☐ ☐ ☐ ☒ ☐
11. Hoist / Davit Crane ☐ ☐ ☐ ☒ ☐
12. Elevator ☒ ☐ ☐ ☐ ☐ A full summary and site specific notation can be referenced in the following sections of this report for more detail on each observation recorded.
Surface Surveillance Systems Assessment Report 4
SECTION 1
Tower
Yes No Comments
1.1 Are there any signs of distress or failure to the
air terminal? ☐ ☒
1.2 Are there any signs of distress or failure to the
down conductor? ☐ ☒
1.3 Are there any signs of distress or failure to the
hardware? ☐ ☒
1.4 Are there any signs of distress or failure to the
mounting hardware? ☒ ☐
1.5 Are there any signs of distress or failure to the
obstruction tower lights? ☐ ☒
1.6 Are there any signs of distress or failure to the
exterior lighting fixtures? ☐ ☒
1.7 Is there a need to replace the exterior lighting
fixtures with LED light bulbs? ☐ ☒
1.8 Are there any signs of distress or failure to the
conduits? ☐ ☒
1.9 Is there a need to replace the conduits with PVC
coated rigid steel conduits? ☐ ☒
1.10 Are there any signs of distress or failure to the
grate hatch / lifting support piston arm? ☒ ☐
1.11 Are there any signs of distress or failure to the
steel junction box? ☐ ☒
1.12 Is there a need to replace the current junction
box with a stainless steel junction box? ☐ ☒
1.13 Are there any signs of distress or failure to the
safety interlocks? ☐ ☒
Notes: The lifting arm for hatch needs replaced. Grating missing clips that need to be replaced.
Surface Surveillance Systems Assessment Report 5
SECTION 2
Concrete Foundation
Yes No Comments
2.1 Have grout pads underneath base plates
deteriorated or otherwise require maintenance? ☐ ☒
2.2 Does the foundation have excess spalling, cracking, or surface erosion? ☐ ☒
2.3 Does the foundation appear to have been repaired
in the past? ☐ ☒
2.4 Are there any other signs of distress or failure?
Explain. ☐ ☒
Notes:
SECTION 3
Tower Painting and Galvanization
Yes No
3.1 Is the tower painted? ☒ ☐
3.2 If painted, is the paint peeling? ☒ ☐
3.3 If painted, based on visual observation, what is the approximate percentage of surface area on the tower that needs to be re-painted? 100 %
3.4 Is the tower hot dipped galvanized? ☒ ☐
3.5 Are there bird feces or other foreign substances present on the tower? If applicable, describe extent, severity, and whether work will be affected. ☐ ☒
Notes: Tower needs to be painted.
Surface Surveillance Systems Assessment Report 6
SECTION 4
Shelters
Yes No Comments
4.1 Base of Tower Equipment Shelter
a. Are there signs of distress or failure to the space heater? ☐ ☒
b. Are there signs of distress or failure to the ventilation hood or screen? ☐ ☒
c. Is there a need to replace the ventilation screen with a steel bug weave screen? ☐ ☒
d. Are there signs of distress or failure to the door frames? ☐ ☒
4.2 Second Level Equipment Shelter
a. Are there signs of distress or failure to the space heater? ☐ ☒
b. Are there signs of distress or failure to the ventilation hood or screen? ☐ ☒
c. Is there a need to replace the ventilation screen with a steel bug weave screen? ☐ ☒
d. Are there signs of distress or failure to the door frames? ☐ ☒
4.3 Below Antenna Equipment Shelter
a. Are there signs of distress or failure to the space heater? ☐ ☒
b. Are there signs of distress or failure to the ventilation hood or screen? ☐ ☒
c. Is there a need to replace the ventilation screen with a steel bug weave screen? ☐ ☒
d. Are there signs of distress or failure to the door frames? ☐ ☒ Lock needs replaced on door.
e. Are there signs of distress or failure to the safety interlocks? ☐ ☒
4.4 Engine Generator Shelter
a. Are there signs of distress or failure to the space heater? ☐ ☒
b. Are there signs of distress or failure to the ventilation hood or screen? ☐ ☒
c. Is there a need to replace the ventilation screen with a steel bug weave screen? ☐ ☒
d. Are there signs of distress or failure to the door frames? ☐ ☒
e. Are there any signs of corrosion on the fuel tanks? ☐ ☒
f. Are there signs of distress or failure to the transformer or the protective bollards? ☐ ☒
Notes: Lock needs to be replaced on door underneath rotodome.
Surface Surveillance Systems Assessment Report 7
SECTION 5
Waveguide
Yes No Comments
5.1 Are there any signs of distress or failure to the
mounting brackets/hardware? ☐ ☒
5.2 Is there any damage to the waveguide? ☐ ☒
5.3 Are there any signs of corrosion? (fading, peeling, cracked) ☐ ☒
5.4 Are there any issues with the operation of the
pressurize system? ☐ ☒
5.5 Are there any issues with the joint weld condition?
(corroded/cracked) ☐ ☒
5.6 Compressor cycle time (on – on)
SECTION 6
Lightning Protection System
Yes No Comments
6.1 Does the system show signs of being in less than
generally good repair? ☐ ☒
6.2 Are there loose connections that might result in
high-resistance joints? ☐ ☒
6.3 Has any part of the system been weakened by
corrosion? ☐ ☒
6.4 Have any of the conductors or grounding electrodes
been severed? ☐ ☒
6.5 Are any conductors or system components
fastened insecurely to its mounting surfaces? ☐ ☒
6.6 Are any conductors or system components subject
to accidental displacement? ☐ ☒
6.7 Have any modifications been made or appurtenances added that require additional bonding to the system?
6.8 Is there any visual hardware damage? ☐ ☒
Surface Surveillance Systems Assessment Report 8
SECTION 7
Main Bearing / Drive System
Yes No Comments
7.1 Drive – Start drive independently from a stall
a. Is there excessive noise or vibration? ☐ ☒
b. Are there any signs of corrosion? (fading, peeling, cracked) ☐ ☒
c. Are there any signs of distress or failure? ☐ ☒
d. Are there any observed oil leaks (ASDE-X) ☐ ☒
7.2 Are there any signs of distress or failure to the
following: (ASDE-3)
a. Intermediate Shaft ☐ ☒
b. Main Bearing ☐ ☒
c. Tensioner ☐ ☒
d. 50mm Belt ☐ ☒
e. 85mm Belt ☐ ☒
f. Slip Clutch ☐ ☒
7.3 Notate date of last replacement for the following:
(ASDE-3)
a. Intermediate Shaft
b. Main Bearing
c. Tensioner
d. 50mm Belt
e. 85mm Belt
f. Slip Clutch
7.4 Workspace height below drives in ft. (ASDE-3)
7.5 Are there any issues with the accessibility of the
workspace? (ASDE-3) ☒ ☐
Notes: Lock needs to be replaced.
Surface Surveillance Systems Assessment Report 9
SECTION 8
Rotary Joint
Yes No Comments
8.1 Install date of rotary joint
8.2 Performance data VSWR
8.3 Is there excessive noise? ☐ ☒
8.4 Are there any signs of corrosion? (fading, peeling, cracked) ☐ ☒
8.5 Are there signs of distress or failure to the rotary
joint? ☐ ☒
8.6 Are there signs of distress or failure to the cabling
and waveguide on the top side of the rotary joint? ☐ ☒
8.7 Are there signs of distress or failure to the cabling and waveguide on the bottom side of the rotary joint?
Notes:
SECTION 9
Antenna Junction Box Enclosures
Yes No Comments
9.1 Junction box orientation
9.2 Are there any issues with the condition of the
box? ☐ ☒
9.3 Are there any issues with the operation of the
safety switch? ☐ ☒
9.4 Are there signs of distress or failure to the wiring, relays, or contactors inside the box? ☐ ☒
9.5 Are there signs of distress or failure to the conduit
& cabling from the junction box to the drives? ☐ ☒
9.6 Are there any signs of corrosion? (fading, peeling, cracked) ☐ ☒
9.7 Are there signs of distress or failure to the
mounting hardware? ☐ ☒
9.8 Are there any signs of water intrusion? ☐ ☒
9.9 Are there any signs that the penetrations of the
box are not weathertight? ☐ ☒
Surface Surveillance Systems Assessment Report 10
SECTION 10
Antenna / Rotodome / Radome
Yes No Comments
10.1 Antenna Type (ASDE-3, ASDE-X Terma, or ASDE-X
Easat) ASDE-3
10.2 Antenna Structure (riser, special mounting, etc.)
10.3 Antenna
a. Notate date of last repair
b. Are there any signs of corrosion (fading, peeling, cracked) ☐ ☒
c. Are there any signs of distress or failure to the wiring? ☐ ☒
d. Are there any signs of distress or failure to the electrical connections? ☐ ☒
10.4 Rotodome (if applicable)
a. Are there any issues with the paint or laminate condition? ☐ ☒ Painted 8/21/24
b. Are there any signs of corrosion on the threshold door? ☐ ☒
c. Are there any signs of distress or failure to the wiring? ☐ ☒
d. Are there any signs of distress or failure to the waveguide? ☐ ☒
e. Are there any signs of distress or failure to the fans/heaters? ☐ ☒
f. Are there any signs of distress or failure to the flashing at the rotodome base? ☐ ☒
10.5 Radome (if applicable)
a. Are there any observed cracks in the caulking? ☐ ☒
b. Does the paint appear to be faded? ☐ ☒
c. Do any panels appear to be damaged? ☐ ☒
Surface Surveillance Systems Assessment Report 11
SECTION 11
Hoist / Davit Crane
Yes No Comments
11.1 Is there a hoist or a Davit crane present? (If so, specify type) ☒ ☐ Chain hoist
11.2 If present, are there any signs of distress or failure
to the following:
a. Chain ☐ ☒
b. Hook ☐ ☒
c. Cable ☐ ☒
11.3 If present, are there any safety concerns? ☐ ☒
11.4 Are there any signs of corrosion to the
chain/hook/cable? (fading, peeling, cracked) ☐ ☒
11.5 Are there any signs of corrosion to the pendant?
(fading, peeling, cracked) ☐ ☒
Notes:
SECTION 12
Elevator
Yes No Comments
12.1 Is the elevator operational? ☐ ☒
12.2 Are there any signs of distress or failure to the
following:
a. Rail ☒ ☐
b. Mounting Hardware ☐ ☒
c. Motor ☐ ☐
d. Safety Interlocks ☒ ☐
12.3 Is the emergency egress ladder present? ☐ ☐
Notes: Elevator does not work, stops at top of elevator are not present. Elevator and ladder are both unsafe to use.
Surface Surveillance Systems Assessment Report 12
SECTION 13
PHOTO CHECKLIST
Capture each photo in accordance with the sequence and description provided Comments
Site 1 Full tower and compound (site) ☒
2 Looking at site from the North/A Face ☐
3 Looking at site from the East/ B Face ☒
4 Looking at site from the South/ C Face ☒
5 Looking at site from the West/ D Face ☒
Structure 6 Leg A from outside looking up (indicate with magic marker each leg) ☐
7 Leg B from outside looking up (indicate with magic marker each leg) ☐
8 Leg C from outside looking up (indicate with magic marker each leg) ☐
9 Leg D from outside looking up (indicate with magic marker each leg) ☐
10 Tower foundation @ the base of leg A
11 Tower foundation @ the base of leg B ☐
12 Tower foundation @ the base of leg C ☐
13 Tower foundation @ the base of leg D ☐
14 Base of tower shelter ☐
15 Second Level Shelter ☒
16 Below antenna shelter ☐
17 Equipment shelter ☐
18 Drive assembly ☒
19 Rotary Joint ☒
20 Antenna Junction Box ☒
21 Antenna Front ☐
22 Hoist ☒
23 Elevator ☒
Deficiencies List pictures of deficiency observed
Surface Surveillance Systems Assessment Report 13
SECTION 14
REFERENCE IMAGES
Insert pictures from site in order of picture checklist
Full tower and compound (site)
Surface Surveillance Systems Assessment Report 14
Looking at tower from East / B Face Looking at tower from East / B Face
Looking at tower from South / C Face Looking at tower from West / D Face
Tower Leg C Second Level Equipment Shelter
Surface Surveillance Systems Assessment Report 17
Elevator Elevator
Boxes Motor
Hand Rails Tower
Surface Surveillance Systems Assessment Report 18
Hatch Grating
Tower Tower
Surface Surveillance Systems Assessment Report 19
Second Level Shelter Second Level Shelter
Second Level Shelter