CONSTRUCTION_DRAWINGS_-_BID_03-19_RCSP_WEST_PARKING_LOT_EXP.pdf
PDF 10 MB Posted
- Attached to
- RSP Parking Lot Expansion
- Solicitation number
- 03-19
- Issued by
- Volusia County, Florida
About this file
This file comprises construction drawings and bidding documents for the Rob Sullivan Community Park West Parking Lot Improvements project, Bid No. 03-19, prepared for the City of DeBary, Florida. The project scope includes clearing and grubbing, stormwater piping and drainage inlet structures, grading and soil stabilization, concrete sidewalk and curb installation, signage, and sodding for the west parking lot expansion at Rob Sullivan Community Park located at 16 Colomba Road, DeBary, Florida 32713. The construction drawings depict a parking lot expansion with approximately 3,452.60 square feet of new asurfaced area, featuring 115 linear feet to 243 linear feet of 18-inch reinforced concrete pipe (RCP) at varying slopes, multiple drainage inlet structures (Types C and D), concrete curb transitions, and associated site improvements. The project requires compliance with Florida Department of Transportation (FDOT) Standard Specifications and the 2010 ADA Standards for Accessible Design. The plans indicate the project was dated April 2019 and prepared by Pegasus Engineering, LLC, with professional engineer David W. Hamstra, P.E. (Registration No. 38652) serving as the design engineer.
The construction documents specify that all work shall conform to FDOT Standard Specifications for Road and Bridge Construction and applicable Florida Administrative Code requirements. The contractor is responsible for stormwater pollution prevention planning (SWPPP) if total clearing exceeds one acre, with notice of intent submission required 48 hours prior to construction commencement. Soil compaction requirements mandate 98 percent maximum density (AASHTO T-180) under pavement and 95 percent density for roadway shoulders. The contractor must coordinate with the City of DeBary Public Works Department, as drainage structures and pipes are to be constructed by that department. Utility coordination is critical, requiring contractor notification of utilities 72 hours prior to excavation and use of the Sunshine State One Call system (1-800-432-4770) a minimum of 48 hours before work begins. The project includes benchmark elevations based on NAVD88 vertical datum with site benchmarks established at elevations 54.80 and 43.85 feet. All existing trees are to remain unless otherwise directed, and contractor shall maintain newly planted vegetation and grasses until project acceptance by the owner.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2nd ST
EAST HIGHBANKS RD
1st ST
DOGWOOD TR
WEST HIGHBANKS RD
N. PINE MEADOW DR
ALICANTE RD
COLOMBA RD
ANGELES RD
PALMIRA RD
VALENCIA RD
PLANTATION RD
ANGELES RD
MA
DE
RA
R D
SH
EL
L R D
LAKE DR
SMYRNA DR
VOLUSIA DR
SEMINOLE DR
CATALINA DR
PALMETTO DR
MONROE AVE
SANFORD AVE
U.
S.
H
IG
HW
AY
-92
NA
RA
NJ
A
RD
NA
RA
NJ
A
RD
WEST HIGHBANKS RD
RA
IL
RO
AD
DO
NA
LD
E
. S
MI
TH
B
LV
D
TERRA ALTA
MOBILE HOME
SUBDIVISION
DEBARY GOLF AND
COUNTRY CLUB
DEBARY PLANTATION BLVD
1" = 800'
VICINITY MAP
ROADS AND PARCELS
SHEET DESCRIPTION
1 COVER SHEET
PROVIDED BY VOLUSIA COUNTY
B I D
N
O
R
B
S
U L L I V
A N
C
M
M U
N I T
Y
P
A R
K
W
E S
T
P
A R
K I N
G
L O
T
I M
P R
O V
E M
E N
T S
NOTES AERIAL LOCATION MAP - PHOTOGRAPHS OF EXISTING CONDITIONS
16 Colomba Road DeBary, Florida 32713 Phone: 386-668-2040 Fax: 386-668-4122
ROB SULLIVAN COMMUNITY PARKROB SULLIVAN COMMUNITY PARK
SHEET INDEX
DATE:
REG. NO.
ENGINEER:
301 West SR 434, Suite 309 Winter Springs, Florida 32708 Office (407) 992-9160
State of Florida Board of Professional Engineers Certificate of Authorization No. 27770
Fax. (407) 358-5155
CI
TY
OF DeBARY
FLORIDA
WEST PARKING LOTWEST PARKING LOT
2 GENERAL NOTES - WEST PARKING LOT IMPROVEMENTS
1. GOVERNING SPECIFICATIONS: STATE OF FLORIDA, DEPARTMENT OF TRANSPORTATION, STANDARD
SPECIFICATIONS (LATEST EDITION) AND SUPPLEMENTS THERETO IF NOTED IN THE SPECIAL
TECHNICAL PROVISIONS FOR THIS PROJECT; U.S. DEPARTMENT OF JUSTICE 2010 ADA STANDARDS
FOR ACCESSIBLE DESIGN.
2. ATTENTION IS DIRECTED TO THE FACT THAT THESE PLANS MAY HAVE BEEN CHANGED IN SIZE BY
REPRODUCTION. THIS MUST BE CONSIDERED WHEN OBTAINING SCALED DATA.
11" X 17" DRAWINGS ~ NOT TO SCALE
12" X 18" DRAWINGS ~ HALF SIZE
24" X 36" DRAWINGS ~ TO SCALE
3. INFORMATION SHOWN WITHIN THESE PLANS ARE REFERENCED TO THE NAVD88 VERTICAL DATUM.
DAVID W. HAMSTRA, P.E.
38652
PROJECT
LOCATION
BID NO. 03-19
TOPOGRAPHIC SURVEY - WEST PARKING LOT IMPROVEMENTS4
April 2019
SURVEY CONTROL - WEST PARKING LOT IMPROVEMENTS
PLAN (1 OF 2) - WEST PARKING LOT IMPROVEMENTS
IMPROVEMENTSIMPROVEMENTS
PLAN AND PROFILE - WEST PARKING LOT IMPROVEMENTS
FOR BIDDING PURPOSES ONLYFOR BIDDING PURPOSES ONLY
TYPICAL SECTIONS - WEST PARKING LOT IMPROVEMENTS
PLAN (2 OF 2) - WEST PARKING LOT IMPROVEMENTS
CROSS-SECTION - PARKING LOT - WEST PARKING LOT IMPROVEMENTS
CROSS-SECTION - PARKING LOT - WEST PARKING LOT IMPROVEMENTS
CROSS-SECTION - PARKING LOT - WEST PARKING LOT IMPROVEMENTS
CROSS-SECTION - ENTRANCE ROAD - WEST PARKING LOT IMPROVEMENTS
MISCELLANEOUS DETAILS - TIMBER FENCE DETAILS
DITCH BOTTOM INLETS - TYPES C, D, E AND H
DITCH BOTTOM INLETS - TYPES C, D, E AND H
SIGNING PLAN - WEST PARKING LOT IMPROVEMENTS
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
NO NAME
AutoCAD SHX Text
SUSAN
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
MOON
AutoCAD SHX Text
HALF
AutoCAD SHX Text
THE WOODS
AutoCAD SHX Text
LAKE OF
AutoCAD SHX Text
LINDA
AutoCAD SHX Text
LAKE LAGO
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text
OLIVIA
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
ANNA
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
MARIA
AutoCAD SHX Text
MAUD
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
MARIE
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
HIBISCUS
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
GEM
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
EAGLE
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
QUAIL
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
TWIN
AutoCAD SHX Text
SOARING
AutoCAD SHX Text Mayor ~ Karen Chasez
AutoCAD SHX Text Vice Mayor ~ Erika Benfield, Seat #2
AutoCAD SHX Text City Manager ~ Ron McLemore
AutoCAD SHX Text Council Seat #1 ~ Stephen Bacon
AutoCAD SHX Text Council Seat #2 ~ Erika Benfield
AutoCAD SHX Text Council Seat #3 ~ Patricia Stephenson
AutoCAD SHX Text Section 29, Township 18S, Range 30E
AutoCAD SHX Text Latitude 28%%D 53m 28s
AutoCAD SHX Text Longitude 81%%D 20m 03s
AutoCAD SHX Text Director - Parks & Recreation ~ John Fletcher
AutoCAD SHX Text %%UProject Location Summary
AutoCAD SHX Text Parks Superindendent - Parks & Recreation ~ Tom VanDeHey
AutoCAD SHX Text Council Seat #4 ~ Phyllis Butlien
ACTUAL LENGTHS INSTALLED.
THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER AND BOTH SHALL NOTIFY:
TALLAHASSEE, FL
SUITE 309
REMOVAL AND REPLACEMENT SHALL BE PROTECTED WITH A CAST IRON VALVE BOX.
(904) 488-2427
3900 COMMONWEALTH BOULEVARD
STATE GEODETIC ADVISOR, RONNIE TAYLOR
SUBMITTED TO THE ENGINEER FOR RESOLUTION, AS SOON AS POSSIBLE AFTER
DRAINAGE / UTILITY CONFLICTS EXIST. INFORMATION ON CONFLICTS IS TO BE
PRIOR TO ORDERING DRAINAGE STRUCTURES, THE CONTRACTOR SHALL DETERMINE IF
RESPONSIBLE FOR COORDINATING UTILITY RELOCATION WITH THE UTILITY OWNER.
OF UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE THERETO AND IS
CONTRACTOR SHALL MAKE HIS OWN DETERMINATION AS TO THE TYPE AND LOCATION
SURVEYS BUT IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. THE
OF UNDERGROUND AND OTHER UTILITIES IS BASED ON AVAILABLE RECORDS AND
THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND LOCATION
BY PERMIT CONDITIONS, REQUIRED STANDARD FDOT SPECIFICATIONS, AND / OR
CONTROLS SHALL BE USED AT LOCATIONS DESIGNATED IN THE PLANS, ESTABLISHED
THE PLANS, PERMITS, AND STANDARDS ADOPTED BY OWNER. ENVIRONMENTAL
THE CONTRACTOR SHALL PERFORM HIS WORK IN ACCORDANCE WITH REQUIREMENTS OF
DISCOVERY.
ALL EXISTING TREES ARE TO REMAIN UNLESS OTHERWISE DIRECTED. IF REQUIRED TO
MAKE HIS OWN DETERMINATION AS TO ALL SUBSURFACE CONDITIONS.
AVAILABLE, TO MAKE ARRANGEMENTS TO REVIEW SAME PRIOR TO BIDDING, AND TO
OF THE CONTRACTOR TO INQUIRE OF THE ENGINEER IF ADDITIONAL INFORMATION IS
THE PLANS GOVERNING CONSTRUCTION OF THE PROJECT. IT IS THE RESPONSIBILITY
INFORMATION IS NOT GUARANTEED AND IS NOT TO BE CONSTRUED AS PART OF
ESTABLISHING DESIGN CRITERIA FOR THE PROJECT. THE ACCURACY OF THIS
SUBSURFACE INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FOR USE IN
BE REMOVED, THE ITEM SHALL BE PAID FOR UNDER "CLEARING AND GRUBBING."
PAVEMENT AREAS SCHEDULED TO BE OPEN-CUT SHALL HAVE THE PAVEMENT CLEANLY
ALL DRAINAGE PIPES SHALL BE REINFORCED CONCRETE PIPE, CLASS III, UNLESS
OTHERWISE SPECIFIED OR DIRECTED BY THE OWNER / ENGINEER.
ANY U.S.C. AND G.S. (UNITED STATES COAST AND GEODETIC SURVEY) MONUMENTS
MEASUREMENT OF DRAINAGE PIPE FOR PAYMENT SHALL BE DETERMINED FROM
WITHIN THE LIMITS OF CONSTRUCTION SHALL BE PROTECTED. IF IN DANGER OF DAMAGE,
SHALL BE PRESERVED. THOSE FOUND IN AREAS WHERE PAVEMENT IS SCHEDULED FOR
ALL PERMANENT REFERENCE MONUMENTS (P.R.M.'s) SHOWN ON THE PLANS, OR FOUND, AS-BUILT DRAWINGS SHALL BE KEPT BY THE CONTRACTOR AND SUBMITTED
THE CONTRACTOR SHALL REMOVE ALL WASTE MATERIAL FROM THE SITE AND
TO PROTECT ADJACENT AREAS FROM CONSTRUCTION ACTIVITIES.
MN-4.
MN-5.
MN-6.
MN-7.
MN-9.
MN-8.
BE ALLOWED.
MN-12.
REGISTERED PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR.
MN-3.
MN-2.
MN-1.
REQUIREMENTS, AND TESTING REQUIREMENTS SPECIFIED IN THE CONTRACT,
PLANS OR SPECIFICATIONS.
PROTECT EXISTING FACILITIES ABOVE AND BELOW THE GROUND.
AND ENGINEER'S CONSULTANT ASSUME NO RESPONSIBILITY FOR SUBSURFACE
CONDITIONS OR FOR THE CONTRACTOR'S FAILURE TO IDENTIFY, LOCATE, AND
IN THE CONTRACT, PLANS, OR SPECIFICATIONS.
LOCATION AND IDENTIFICATION OF EXISTING UTILITIES, DRAINAGE SYSTEMS OR
SURVEYORS.
TO THE OWNER UPON PROJECT COMPLETION, PRIOR TO FINAL CERTIFICATION
THE CONTRACTOR SHALL CLEARLY MARK THE LIMITS OF WORK PRIOR TO CLEARING
DISPOSE OF IT IN AN APPROVED MANNER. BURNING ON SITE WILL NOT BE ALLOWED.
OF SUBSTANTIAL COMPLETION BY THE ENGINEER. THESE AS-BUILT DRAWINGS
ALL PERSONAL PROPERTY, EXCEPT MAILBOXES, WITHIN THE RIGHT-OF-WAY NOT
RELOCATED BY THE PROPERTY OWNER(S) SHALL BE REMOVED BY THE CONTRACTOR
AS NECESSARY TO CONSTRUCT THE PROJECT IN ACCORDANCE WITH THE PLANS.
MAIL BOXES SHALL BE RELOCATED BY THE CONTRACTOR IN ACCORDANCE WITH
FDOT's ROADWAY AND TRAFFIC DESIGN STANDARDS (INDEX NO. 532).
ALL PRIVATE AND PUBLIC PROPERTY AFFECTED BY THIS WORK SHALL BE RESTORED
TO A CONDITION EQUAL TO OR BETTER THAN THE CONDITION EXISTING PRIOR TO
COMMENCING CONSTRUCTION, UNLESS SPECIFICALLY EXEMPTED BY THE PLANS. COST
TO BE INCIDENTAL TO OTHER CONSTRUCTION AND NO EXTRA COMPENSATION TO
THE CONTRACTOR SHALL PROVIDE ALL SHEETING, SHORING, AND BRACING REQUIRED
TO PROTECT ADJACENT STRUCTURES AND UTILITIES, OR TO MINIMIZE TRENCH WIDTH
AS REQUIRED. SHEETING AND SHORING SHALL BE DESIGNED BY A STATE OF FLORIDA
WITH THE LINES, GRADES, PROFILES, CROSS-SECTIONS, DIMENSIONS, MATERIAL
ALL WORK AND MATERIALS FURNISHED SHALL BE IN REASONABLE CONFORMITY
PHYSICAL STRUCTURES WITHIN THE LIMITS OF WORK. THE OWNER, HIS ENGINEER,
THE CONTRACTOR SHALL NOT EXCAVATE, REMOVE, OR OTHERWISE DISTURB ANY
MATERIAL, STRUCTURE, OR PART OF A STRUCTURE WHICH IS LOCATED OUTSIDE
EXCEPT WHERE SUCH EXCAVATION, REMOVAL, OR DISTURBANCE IS PROVIDED FOR
AFFECT HIS WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISCOVERY,
THE CONTRACTOR SHALL EXAMINE THE SITE FOR ALL CONDITIONS WHICH MAY
THE LINES, GRADES, OR CONSTRUCTION LIMITS ESTABLISHED FOR THIS PROJECT,
APPARENT ERRORS, DISCREPANCIES OR OMISSIONS ON THE DRAWINGS SHALL BE
BROUGHT TO THE ENGINEER'S ATTENTION BEFORE BIDDING. NO EXTRA PAYMENT WILL
BE ALLOWED FOR ANY WORK REQUIRED DUE TO MISUNDERSTANDING OF JOB OR SITE
CONDITIONS AFFECTING THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS OR
SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL NOT TAKE ADVANTAGE OF ANY
SHALL COMPLY WITH THE FLORIDA ADMINISTRATIVE CODE (F.A.C.) FOR
DOCUMENTS. THE TENDERING OF A PROPOSAL WILL ACKNOWLEDGE ACCEPTANCE OF
APPARENT ERROR OR OMISSION IN THE DRAWINGS OR SPECIFICATIONS, AND THE
ENGINEER SHALL BE PERMITTED TO MAKE CORRECTIONS AND INTERPRETATIONS AS
MAY BE DEEMED NECESSARY FOR FULFILLMENT OF THE INTENT OF THE CONTRACT
AND IN ACCORDANCE WITH ASTM C-478 UNLESS OTHERWISE SPECIFIED.
ALL MANHOLES, INLETS, AND JUNCTION BOX STRUCTURES SHALL BE PRECAST
ALL PIPE JOINT CONNECTIONS SHALL BE WRAPPED WITH A FILTER FABRIC MATERIAL
IN ACCORDANCE WITH FDOT's ROADWAY AND TRAFFIC DESIGN STANDARDS (FDOT
ALL MANHOLES, INLETS, BASIN DRAINS AND JUNCTION BOX STRUCTURES SHALL HAVE
TRAFFIC BEARING FRAMES AND COVERS, OR GRATES MEETING HS-20 LOADING
REQUIREMENTS, UNLESS OTHERWISE SPECIFIED WITHIN THE PLANS. THE COST FOR
ALL EXISTING AND INSTALLED STORM SEWER LINES AND INLETS SHALL BE CLEANED
OF DEBRIS AND ERODED MATERIALS AT THE LAST STAGE OF CONSTRUCTION, THE
COST OF WHICH SHALL BE INCIDENTAL TO THE PROJECT CONSTRUCTION. BEFORE
COMMENCING CONSTRUCTION, THE CONTRACTOR SHALL BRING TO THE ATTENTION OF
THE ENGINEER ALL EXISTING DRAINAGE PROBLEMS OR DRAINAGE PROBLEMS THAT
WILL BE CREATED BY THIS OPERATION.
SW-1.
SW-2.
SW-4.
SW-5.
INDEX NO. 280).
OBTAIN WRITTEN PERMISSION FROM THE PROPERTY OWNER TO THERE SO
OCCUPY FOR THE SOLE PURPOSE OF PROSECUTING THE WORK. THE CONTRACTOR
BEFORE COMMENCING WORK ON ANY PRIVATE LANDS, THE CONTRACTOR SHALL
SHALL USE ALL DUE CAUTION AND CARE TO PROTECT THE PROPERTY AT ALL
TIMES AND IN ALL MANNER FROM HIS WORK AND TO LIMIT HIS ACTIVITIES
AS NECESSARY TO PERFORM THE WORK AS DESCRIBED BY THE CONTRACT
DOCUMENTS. IF THE WORK IS INCOMPLETE AT THE END OF THE WORK DAY,
HE SHALL SECURE THE WORK AREA AND MATERIALS TO PROVIDE FOR THE
CONSIDERATION AND THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
SAFETY OF ALL PERSONS, KNOWN OR UNKNOWN. SAFETY SHALL BE A PRIME
FROM THE GOVERNMENTAL ENTITY HAVING JURISDICTION OVER SAID AREA.
SPECIFICALLY DESCRIBED BY THE PLANS AND GRANTED BY REASON OF PERMIT
BUFFER AREA, MITIGATION AREA, OR DESIGNATED WETLAND AREA UNLESS
ABSOLUTELY NO WORK WILL BE ALLOWED WITHIN ANY CONSERVATION AREA,
STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
IF THE TOTAL AREA TO BE CLEARED IS EQUAL TO, OR EXCEEDS ONE (1) ACRE,
THEN THE CONTRACTOR WILL BE RESPONSIBLE FOR PREPARING A STORMWATER
POLLUTION PREVENTION PLAN (SWPPP) IN ACCORDANCE WITH EPA'S NPDES
REGULATIONS. THE CONTRACTOR WILL BE RESPONSIBLE FOR SUBMITTING A NOTICE
OF INTENT (NOI) AND APPLICABLE FEES TO THE FDEP NO LESS THAN FORTY-EIGHT
(48) HOURS PRIOR TO COMMENCING CONSTRUCTION. THE COST FOR THIS WILL BE
AND MAINTAIN ALL BARRICADES, WARNING SIGNS, AND MARKINGS FOR
PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL FURNISH, ERECT
CONSTITUTES IN ANY WAY A HAZARD TO THE PUBLIC.
WHERE THE WORK CAUSES OBSTRUCTION TO THE NORMAL TRAFFIC OR
THE OWNER, SUCH AS TO EFFECTIVELY PREVENT ACCIDENTS IN ALL PLACES
TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS, OR AS DIRECTED BY
WITH THE U.S. DEPARTMENT OF TRANSPORTATION MANUAL OF UNIFORM
HAZARDS AND THE CONTROL OF TRAFFIC, IN REASONABLE CONFORMITY
MAINTENANCE OF TRAFFIC: ACCESS FOR LOCAL TRAFFIC WITH DESTINATIONS WITHIN
THE PROJECT LIMITS SHALL BE MAINTAINED. IF ACCESS TO LOCAL TRAFFIC IS CHANGED
DURING CONSTRUCTION, THEN THE CONTRACTOR SHALL NOTIFY THE OWNER A
MINIMUM OF THREE (3) WORKING DAYS IN ADVANCE. IF ROAD CLOSURES ARE
REQUIRED DURING CONSTRUCTION, THEN THE CONTRACTOR SHALL NOTIFY THE
OWNER A MINIMUM OF FIVE (5) WORKING DAYS IN ADVANCE.
RP-7.
RP-8.
RP-9.
EW-2.
EW-3.
GS-5.
EW-4.
EW-1.
THE CONTRACTOR SHALL EXAMINE THE SITE, REVIEW THE PLANS, AND
INDEPENDENTLY DETERMINE THE VOLUME OF EXCAVATION, FILL AND/OR
BACKFILL REQUIRED TO PERFORM THE WORK.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF SLOPES
AND EMBANKMENTS. THE CONTRACTOR SHALL REPAIR OR REMEDY DAMAGE
TO SUCH IF CAUSED BY EROSION, CONTRACTOR ACTIVITIES OR LACK OF
MAINTENANCE UNTIL THE PROJECT IS ACCEPTED BY THE OWNER.
ALL FILL PLACED WITHIN PROPOSED ROAD RIGHT-OF-WAYS SHALL BE
COMPACTED AS FOLLOWS:
THE ENGINEER HAS UTILIZED TOPOGRAPHIC SURVEY INFORMATION WHICH HE
HAS RELIED UPON IN THE PREPARATION OF THESE PLANS. THE CONTRACTOR IS
EMBANKMENT IS STARTED.
OTHERWISE REMOVE ALL VEGETATION AND OTHER DELETERIOUS MATERIAL BEFORE
IN ALL AREAS WHICH REQUIRE FILL MATERIAL, THE CONTRACTOR WILL STRIP OR
ROADWAY SHOULDERS (OUTSIDE PAVEMENT) 95% MAX. DENSITY, AASHTO T-180.
ROADWAY AREAS (UNDER PAVEMENT) 98% MAX. DENSITY, AASHTO T-180.
MT-2.
MT-1.
EW-5.
BE ALLOWED.
GS-2.
FOR SELECT DISPOSAL. IN NO CASE WILL BURIAL OF DISPOSABLE MATERIAL
REMOVED FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR UNLESS
OTHERWISE DIRECTED BY THE OWNER OR SPECIFIED ELSEWHERE IN THE PLANS
ALL SOIL STRIPPINGS, DELETERIOUS AND UNSUITABLE MATERIAL SHALL BE
PROPOSED STATION OFFSETS ARE FROM THE CENTERLINE OF THE STRUCTURE
PUBLIC LAND CORNERS WITHIN THE LIMITS OF CONSTRUCTION SHALL BE PROTECTED.
IF A CORNER MONUMENT IS IN DANGER OF BEING DESTROYED OR DISTURBED,
THE CONTRACTOR SHALL NOTIFY THE OWNER AND THE PROJECT ENGINEER, WITHOUT
DELAY, BY TELEPHONE. THE CONTRACTOR SHALL PROVIDE WRITTEN FOLLOW UP
CONFIRMATION WITHIN FORTY-EIGHT (48) HOURS OF TELEPHONE NOTIFICATION.
GS-6. BENCHMARKS AND VERTICAL ELEVATIONS AREA BASED ON NAVD88 DATUM.
GS-3.
GS-4.
INCLUDED IN THE CONTRACT UNIT PRICE FOR "MOBILIZATION/DEMOBILIZATION, LS."
REQUIRED BY THE AUTHORITY HAVING JURISDICTION WHERE THE WORK OCCURS.
THE CONTRACTOR SHALL OBTAIN A RIGHT-OF-WAY UTILIZATION PERMIT AS NECESSARY ORRP-6.
RP-5. THE CONTRACTOR MUST OBTAIN A CONSUMPTIVE USE PERMIT (CUP) IF DEWATERING
IS NECESSARY.
RESTORED TO A CONDITION EQUAL TO OR BETTER THAN THEIR ORIGINAL CONDITION.
MULCHED. ALL DISTURBED AREAS OUTSIDE THE LIMITS OF GRADING SHALL BE
GRADED AREAS NOT SCHEDULED FOR SODDING OR PAVING SHALL BE SEEDED AND
TREATMENT IS PRESCRIBED IN THE PLANS OR CONTRACT DOCUMENTS. ALL OTHER
EC-6. ALL DISTURBED PERVIOUS AREAS SHALL BE SODDED, UNLESS OTHER SURFACE
EC-5. IF NOT SPECIFIED ELSEWHERE; SEEDING, MULCHING, AND SODDING SHALL BE IN
ACCORDANCE WITH FDOT's STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, (latest edition).
EC-2. THE CONTRACTOR SHALL EMPLOY SUCH EROSION CONTROL METHODS AS
THE REMOVAL OF THE BARRIERS.
BEEN ESTABLISHED. THEREAFTER, THE CONTRACTOR WILL BE RESPONSIBLE FOR
CONSTRUCTION IS COMPLETED AND SOILS ARE STABILIZED AND VEGETATION HAS
AND TURBIDITY BARRIERS MUST REMAIN IN PLACE AT ALL LOCATIONS UNTIL
EC-4. SILT SCREENS AND TURBIDITY BARRIERS MUST BE INSTALLED AT ALL LOCATIONS
WHERE THE POSSIBILITY OF TRANSFERRING SUSPENDED SOLIDS INTO THE
RECEIVING WATERBODY EXISTS DUE TO THE PROPOSED WORK. SILT SCREENS
EC-8.
STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (latest edition).
ACCORDANCE WITH FDOT's ROADWAY AND TRAFFIC DESIGN STANDARDS AND
INSTALLATION OF SILT FENCES AND TURBIDITY BARRIERS SHALL BE IN EC-3.
RP-4.
RP-3.
RP-2.
RP-1.
RECOMMENDATIONS REGARDING CONSTRUCTION OF THE PROPOSED IMPROVEMENTS.
FOR THE CONTRACTOR'S INDEPENDENT REVIEW. THIS REPORT CONTAINS SPECIFIC
A GEOTECHNICAL ENGINEERING REPORT HAS BEEN PREPARED AND IS AVAILABLEGT-1.
DeBary, Florida 32713 16 Colomba Road
SHALL HAVE THE INDICATED MEANING:
THE CONTRACTOR SHALL PROVIDE A MINIMUM OF FIVE (5) FEET OF SOD AROUND ALL
DITCH BOTTOM INLETS, MANHOLES AND ENDWALLS, IN AREAS NOT SCHEDULED
FOR PAVEMENT OR CONCRETE.
A GEOTECHNICAL ENGINEER WILL BE PROVIDED BY THE OWNER TO: MAKE
DETERMINATIONS ON THE SUITABILITY OF MATERIAL ACQUIRED FROM EXCAVATIONS
OR BORROW OPERATIONS; AND TO DETERMINE FILL SUITABILITY AND CONTROL
FOR EMBANKMENT OPERATIONS OR, THE STOCKPILING OF SURPLUS SOIL. THE
CONTRACTOR WILL COOPERATE WITH THE GEOTECHNICAL ENGINEER AS REQUIRED
TO DO THE WORK.
OR MISCONDUCT IN HIS MANNER OR METHOD OF EXECUTING THE WORK, OR AT
PLANTED GRASSES AND VEGETATION UNTIL THE WORK HAS BEEN ACCEPTED BY
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL NEWLY
ANY TIME DUE TO DEFECTIVE WORK OR MATERIALS.
THE OWNER.
EC-7.
THE OWNER'S CONSULTANT FOR SCHEDULING ALL TESTING PRIOR TO
CONSTRUCTION WORK. THE CONTRACTOR SHALL PROVIDE SUFFICIENT NOTICE FOR
THE CONTRACTOR SHALL ENSURE THAT PROPER SOIL DENSITIES ARE ACHIEVED
FOR THE PLACEMENT OF ALL STRUCTURES, OR COMPACTED EARTH. SOIL TESTING
SHALL BE PROVIDED BY THE CONTRACTOR. THE CONTRACTOR SHALL COORDINATE WITH
THE CONTRACTOR SHALL CONFORM AND ADHERE TO THE POLICIES ESTABLISHED
BY THE CITY OF DEBARY AND/OR VOLUSIA COUNTY FOR THE PRESERVATION
OF ALL PUBLIC AND PRIVATE PROPERTY. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR ALL DAMAGE AND INJURY TO PROPERTY OF ANY CHARACTER, DURING THE
PROSECUTION OF THE WORK, RESULTING FROM ANY ACT, OMISSION, NEGLIGENCE,
TESTING WORK IN ADVANCE OF CONSTRUCTION. THE CONTRACTOR SHALL ADHERE
GT-3.
GT-2.
SEDIMENT RUNOFF FROM THE SITE DURING CONSTRUCTION.
CRITERIA AND SCHEDULES, AND FOR SIGNING FOR SAID INSPECTIONS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEETING ALL INSPECTION
THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE, AND
MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO CONTROL EROSION AND
LOCAL LAWS AND REGULATIONS CONTROLLING POLLUTION OF THE ENVIRONMENT.
EC-1.
THE CONTRACTOR SHALL COMPLY WITH ALL LEGAL LOAD RESTRICTIONS WHEN
HAULING MATERIALS OR EQUIPMENT BEYOND THE LIMITS OF THE WORK. A
SPECIAL PERMIT WILL NOT RELIEVE THE CONTRACTOR FROM ANY LIABILITY FOR
DAMAGE OR INJURY WHICH MAY RESULT FROM MOVING EQUIPMENT OR MATERIAL.
IMPROVEMENTS PRIOR TO ACCEPTANCE BY THE OWNER.
WITHIN SAID PERMITS REGARDING THE WORK AND MAINTENANCE OF
ADHERE TO ALL APPLICABLE REQUIREMENTS OR SPECIAL CONDITIONS STATED
BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL SATISFY AND
THE CONTRACTOR SHALL ENSURE THAT ALL REQUIRED PERMITS ARE IN HAND
WHEN USED IN THESE GENERAL NOTES, THE WORD "OWNER"
GT-4.
TO THE "ASSESSMENT AND RECOMMENDATIONS" CONTAINED WITHIN THE
PRIOR TO BEGINNING ANY CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT TO
THE REFERENCE POINT TIES SHOWN ON THE PLAN AND PROFILE SHEETS, AND/OR
SUBMIT A SET OF FIELD NOTES FOR ALL ADDITIONAL BENCHMARK AND REFERENCE
POINT TIES PROPOSED TO BE USED IN CONSTRUCTING THE PROJECT WITH THEIR
LOCATION, DESCRIPTION AND ELEVATION BASED ON VOLUSIA COUNTY DATUM.
ALL SUBMITTALS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL LAND
SURVEYOR REGISTERED IN THE STATE OF FLORIDA.
THE OWNER A SET OF FIELD NOTES VERIFYING THE BENCHMARK ELEVATIONS AND
GS-1.
BEFORE ESTABLISHING ANY LAYOUT CONTROL.
GS-7.
TO THE PROJECT BASELINE, UNLESS NOTED OTHERWISE.
UL-4.
UL-3.
UL-2.
UL-1.
CONTRACTOR OF HIS RESPONSIBILITY TO PROTECT SUCH EXISTING FEATURES FROM
THE CONTRACTOR SHALL LOCATE AND VERIFY THE DEPTHS AND LOCATIONS
ANY STRUCTURES.
OF ALL EXISTING UTILITIES WITHIN THE LIMITS OF WORK, PRIOR TO ORDERING
ARISE BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS, WHICH WOULD
DAMAGE OR UNSCHEDULED INTERRUPTION OF SERVICES. SHOULD A DISCREPANCY
TO THE CONTRACT.
RELOCATED BY THE RESPECTIVE UTILITY COMPANY AND THE CONTRACTOR SHALL
RELOCATION, DISRUPTION OF SERVICE, OR CLARIFICATION OF UTILITY ACTIVITY.
UTILITY COMPANIES TO MAKE THE NECESSARY ARRANGEMENTS FOR ANY
HALT CONSTRUCTION AND NOTIFY THE OWNER IMMEDIATELY.
COOPERATE WITH THE UTILITY COMPANY DURING RELOCATION OPERATIONS.
THE CONTRACTOR SHALL EXERCISE CAUTION WHEN CROSSING A UTILITY, WHETHER
ANY DELAY OR INCONVENIENCE BY THE VARIOUS UTILITIES SHALL BE INCIDENTAL
UTILITIES WHICH INTERFERE WITH THE PROPOSED CONSTRUCTION SHALL BE
UNDERGROUND OR OVERHEAD, WHETHER SHOWN ON THESE PLANS OR FIELD LOCATED.
EXISTING UTILITIES PRIOR TO CONSTRUCTION, AND FOR NOTIFYING THE VARIOUS
THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND VERIFYING ALL
APPRECIABLY AFFECT THE EXECUTION OF THESE PLANS, THE CONTRACTOR WILL
CONTRACTOR. THE OWNER AND HIS REPRESENTATIVE DO NOT GUARANTEE
THE ACCURACY OR THE COMPLETENESS OF THE LOCATION INFORMATION PROVIDED.
ANY INACCURACY OR OMISSION IN SUCH INFORMATION SHALL NOT RELIEVE THE
AVAILABLE INFORMATION AND ARE PROVIDED FOR THE CONVENIENCE OF THE
FEATURES SHOWN ON THE PLANS HAVE BEEN DETERMINED FROM THE BEST
THE LOCATION OF ALL EXISTING UTILITY SERVICES, FACILITIES, AND STRUCTURAL
UTILITIES ENCOUNTERED:UL-6.
SPECIFIED BY THE FDOT's ROADWAY AND TRAFFIC DESIGN STANDARDS AND STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (latest edition).
ALL REINFORCED CONCRETE PIPE SHALL BE OF THE CLASS AND BEDDING
SPECIFIED BY FDOT's ROADWAY AND TRAFFIC DESIGN STANDARDS, (latest edition).
SW-3.
THESE CONDITIONS BY THE BIDDER.
SW-6.
SW-7.
MN-11.
THE CONTRACTOR SHALL CLEARLY MARK THOSE TREES SCHEDULED FOR REMOVAL,
PROTECTION, AND REPLACEMENT.
SAW-CUT BEFORE REMOVAL OF MATERIAL. THE CONTRACTOR SHALL DIRECT HIS WORK
TO PROTECT THE REMAINING PAVEMENT EDGES FROM BREAKING, CRACKING, OR
RAVELING TO PROVIDE AN ACCEPTABLE EDGE TO RECEIVE THE CONCRETE REPAIR.
SEE OPEN-CUT DETAILS IN THE PLANS.
MN-13.
AS DESIGNATED BY THE ENGINEER.
THE CONTRACTOR SHALL COORDINATE WITH THE OWNER OR THE ENGINEER
THE CONTRACTOR SHALL PROTECT ALL EXISTING TRAFFIC AND STREET SIGNS.MT-3.
WHEN TEMPORARY REMOVAL, RELOCATION, OR REPLACEMENT OF SUCH SIGNAGE
IS REQUIRED DUE TO THE NATURE OF HIS WORK.
SW-8.
(UNDER PART III OF CH. 62-610 F.A.C.)
REQUIRED VERTICAL SEPARATION BETWEEN UNDERGROUND WATER
MAIN IS LAID AT LEAST SIX (6) INCHES ABOVE THE TOP OF THE
REDUCED TO THREE (3) FEET WHERE THE BOTTOM OF THE WATER
WATER MAINS AND GRAVITY-TYPE SANITARY SEWERS SHALL BE
THE MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN
STORMWATER FORCE MAINS, AND RECLAIMED WATER PIPELINES:
MAINS AND SANITARY OR STORM SEWERS, WASTEWATER OR
SEWER.
(PREFERABLY 10')
WATER MAINS AND SANITARY OR STORM SEWERS, WASTEWATER OR
LINES THAT ARE UNDER THE CONTROL OF A PUBLIC WATER SYSTEM
PROCESS PIPING, CONVEYING EITHER RAW, PARTIALLY TREATED, OR
"WATER MAINS" SHALL MEAN MAINS, INCLUDING TREATMENT PLANT
STORMWATER FORCE MAINS, RECLAIMED WATER PIPELINES, AND
ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS:
REQUIRED HORIZONTAL SEPARATION BETWEEN UNDERGROUND
AND THAT HAVE AN INSIDE DIAMETER OF THREE (3) INCHES OR
FINISHED DRINKING WATER; FIRE HYDRANT LEADS; AND SERVICE
RELOCATED
WM
NEW OR
OUTSIDE
OUTSIDE TO
CONDITION A:
GREATER.
3' MIN
- STORM SEWER
EXISTING OR PROPOSED
- STORMWATER FORCE MAIN
- RECLAIMED WATER MAIN
SEWAGE TREATMENT AND DISPOSAL SYSTEMS.
REQUIRED SEPARATION BETWEEN FIRE HYDRANT DRAINS AND
SANITARY OR STORM SEWERS, WASTEWATER OR STORMWATER
FORCE MAINS, RECLAIMED WATER PIPELINES, AND ON-SITE
DRAIN
CONDITION A:
FIRE HYDRANT
AT THE UTILITY CROSSINGS, ONE (1) FULL LENGTH OF WATER MAIN
PIPE SHALL BE CENTERED ABOVE OR BELOW THE OTHER PIPELINE SO
THE WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE
OTHER PIPELINE. ALTERNATIVELY, AT SUCH CROSSINGS, THE PIPES
SHALL BE ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST
THREE (3) FEET FROM ALL JOINTS IN VACUUM-TYPE SANITARY SEWERS,
STORM SEWERS, STORMWATER FORCE MAINS, OR PIPELINES
CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF
CHAPTER 62-610, F.A.C., AND AT LEAST SIX (6) FEET FROM ALL JOINTS
IN GRAVITY-OR PRESSURE-TYPE SANITARY SEWERS, WASTEWATER
FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER (NOT
REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.)
REQUIRED SEPARATION BETWEEN WATER MAINS AND SANITARY
NO WATER MAIN SHALL PASS THROUGH, OR COME INTO
CONTACT WITH, ANY PART OF A SANITARY SEWER MANHOLE.
WATER MAINS SHALL NOT BE CONSTRUCTED OR ALTERED TO
PASS THROUGH, OR COME INTO CONTACT WITH, ANY PART OF A
STORM SEWER MANHOLE OR INLET STRUCTURE.
OR STORM SEWER MANHOLES:
CONDITION B:
OUTSIDE TO
OUTSIDE
3' MIN
(PREFERABLY 10')
OUTSIDE TO
OUTSIDE
6' MINCONDITION C:
CONDITION A:
CONDITION B:
3' MIN
CONDITION B:
6' MIN
FIRE HYDRANT
CONDITION C:
10' MIN
FIRE HYDRANT
MN-10.
CONDITIONS.
ALL LANDSCAPING, PLANTS AND MULCH SHALL BE RESTORED TO PRE-CONSTRUCTIONMN-14.
ADVISED TO OBTAIN A SIGNED AND SEALED COPY OF THE TOPOGRAPHIC SURVEY
GEOTECHNICAL REPORT. CONTRACTOR SHALL PROVIDE FOR A CERTIFIED TESTING LABORATORY
1.
2.
3.
NOTE
4.
A.
B.
RELOCATED
WM
NEW OR
RELOCATED
WM
NEW OR
- VACUUM-TYPE SANITARY SEWER
EXISTING OR PROPOSED
(UNDER PART III OF CH. 62-610 F.A.C.)
- GRAVITY-OR PRESSURE-TYPE SANITARY SEWER
EXISTING OR PROPOSED
- WASTEWATER FORCE MAIN
- RECLAIMED WATER MAIN
TYPE SANITARY SEWER, WASTEWATER,
EXISTING OR PROPOSED PRESSURE
STORMWATER, OR RECLAIMED WATER
FORCE MAIN
RELOCATED
WM (ABOVE CONDITIONS)
NEW OR
RELOCATED
WM (ABOVE CONDITIONS)
NEW OR
GRAVITY OR VACUUM TYPE
EXISTING OR PROPOSED
SANITARY SEWER OR
STORM SEWER
RELOCATED
WM (ABOVE CONDITIONS)
NEW OR
RELOCATED
WM (ABOVE CONDITIONS)
NEW OR
(UNDER PART III OF CH. 62-610 F.A.C.)
- STORM SEWER
EXISTING OR PROPOSED
- WASTEWATER FORCE MAIN
- RECLAIMED WATER MAIN
- VACUUM-TYPE SANITARY SEWER
DRAIN
DRAIN
(UNDER PART III OF CH. 62-610 F.A.C.)
EXISTING OR PROPOSED
- WASTEWATER FORCE MAIN
- RECLAIMED WATER MAIN
- GRAVITY-OR PRESSURE-TYPE SANITARY SEWER
EXISTING OR PROPOSED
TREATMENT AND DISPOSAL SYSTEM
- AT LEAST 10' FROM ANY ON-SITE SEWAGE
Phone: 407-668-2040
FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF STRUCTURE.
PIPE LENGTHS AND SLOPES DEPICTED ON THE PLAN AND PROFILE SHEETS ARE MEASURED
COVERED WITH AN ASPHALTIC MASTIC COATING, AND WRAPPED WITH A
FOR ROAD AND BRIDGE CONSTRUCTION (latest edition).
PIPE BID ITEM OR FOR MODIFICATION OF PRECAST STRUCTURES.
NOT BE CONSIDERED AS A BASIS FOR ADDITIONAL COMPENSATION FOR THE PERTINENT
FILTER FABRIC MATERIAL PER SECTION 430 OF FDOT's STANDARD SPECIFICATIONS
ALL INLET/MANHOLE - PIPE JOINTS SHALL BE FILLED WITH NON-SHRINK GROUT,
CHANGES OF PIPE INVERTS NOT EXCEEDING PLUS OR MINUS ONE (1) FOOT WILL
SW-9.
SW-10.
SW-11.
PRIOR TO EXCAVATING IN THE VICINITY OF A GAS PIPELINE THE CONTRACTOR
OF FLORIDA STATUTES, PROTECTION OF UNDERGROUND PIPELINES,
SHALL NOTIFY THE GAS UTILITY OWNER IN ACCORDANCE WITH THE REQUIREMENTS
F.S. 553.851, CH. 77-143.
UL-5. THE CONTRACTOR SHALL NOTIFY UTILITIES 72 HRS. PRIOR TO EXCAVATION, IN
SAFETY ACT, F.S. 556.101-111. THE CONTRACTOR SHALL USE THE SERVICES OF A ONE
ACCORDANCE WITH THE FLORIDA UNDERGROUND FACILITIES DAMAGE PREVENTION
NUMBER IDENTIFICATION SYSTEM (O.N.I.S.) AND CALL FOR A UTILITY LOCATOR A
MINIMUM OF 48 HOURS PRIOR TO THE COMMENCEMENT OF WORK.
SUNSHINE STATE ONE CALL
11 PLANTATION ROAD
DEBARY, FL 32713
1-800-432-4770
VI-1.
OF CONSTRUCTION TO THE OWNER BEFORE CONSTRUCTION COMMENCEMENT.
THE CONTRACTOR SHALL SUBMIT A VIDEO OF THE PROJECT AREAS WITHIN THE LIMITS
VI-2.
AT&T / TRANSMISSION
6000 METRO WEST BOULEVARD, SUITE 201
ORLANDO, FL 32835-7631
407-578-8000 (STEFAN ERIKSSON)
DUKE ENERGY
DELAND OPERATIONS CENTER
FLORIDA PUBLIC UTILITIES COMPANY
450 SOUTH U.S. HWY 17-92
DEBARY, FL 32713
386-668-9338, EXT. 4138 (DANIELLE BALLINGER)
LEVEL (3) COMMUNICATIONS, LLC
1025 ELDORADO BOULEVARD, 33A-518
BROOMFIELD, CO 80021
720-888-4988 (KELLI WHITEHEAD)
AT&T / DISTRIBUTION
450 NORTH GOLDENROD ROAD
ORLANDO, FL 32807
407-273-5084 (JIM FERRELL)
SUNESYS, LLC
1700 WATER PLACE, SUITE 100
ATLANTA, GA 30339
770-984-6832 (CLINT DECK)
VOLUSIA COUNTY WATER RESOURCES & UTILITIES
123 WEST INDIANA AVENUE
DELAND, FL 32720
376-943-7027, EXT. 12076 (SCOTT MAYS)
386-943-3907
386-547-6874 (JEFF HERRING)
CONCRETE SLABS FOR NYLOPLAST BASIN DRAINS SHALL BE INCLUDED IN THE COST FOR
THE BASIN DRAINS. CONCRETE SLAB DIMENSIONS SHALL BE ACCORDING TO PLANS.
TO CONDUCT SOIL DENSITY TESTING AND SUBMT A COPY OF ALL DENSITY TEST REPORTS TO THE
CITY OF DEBARY.
VI-2. THE CITY OF DEBARY WILL PROVIDE CCTV INSPECTION OF ALL STORMWATER STRUCTURES AND
PIPES. THE CONTRACTOR SHALL COORDINATE WITH THE CITY'S PROJECT REPRESENTATIVE TO
SCHEDULE CCTV INSPECTION PRIOR TO FINAL PAVING OR SURFACE RESTORATION.
CITY OF DeBARY PUBLIC WORKS
16 COLUMBO ROAD
DeBARY, FL 32713
386-668-2040 (ALAN WILLIAMSON)
DAVID W. HAMSTRA, P.E.
REGISTRATION No. 38652
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.: DYC-22044
DWH
CADD
DWH
APRIL 2019
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
SHEET OF 17
RO
B
SU
LL
IV
AN
C
OM
MU
NI
TY
P
AR
K
W
ES
T
PA
RK
IN
G
LO
T
IM
PR
OV
EM
EN
TS
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
Fax. (407) 358-5155
Certificate of Authorization No. 27770
Office (407) 992-9160
Pegasus Engineering, LLC
AutoCAD SHX Text
%%UMISCELLANEOUS NOTES
AutoCAD SHX Text
%%USTORM WATER (DRAINAGE)
AutoCAD SHX Text
%%UEARTHWORK
AutoCAD SHX Text
%%UGEOMETRY & SURVEY
AutoCAD SHX Text
%%UMAINTENANCE OF TRAFFIC (MOT)
AutoCAD SHX Text %%uREGULATORY AND PERMITTING
AutoCAD SHX Text %%uGEOTECHNICAL AND TESTING
AutoCAD SHX Text
%%UEROSION CONTROL AND POLLUTION ABATEMENT
AutoCAD SHX Text
%%UDEFINITION:
AutoCAD SHX Text
CITY OF DEBARY
AutoCAD SHX Text
%%UUTILITIES
AutoCAD SHX Text
12" MIN
AutoCAD SHX Text
6" MIN (12" PREFERABLY)
AutoCAD SHX Text
12" MIN
AutoCAD SHX Text
12" MIN
AutoCAD SHX Text %%uFDEP NOTES
AutoCAD SHX Text
%%UVIDEO INSPECTIONS
AutoCAD SHX Text
%%UCOMMUNICATIONS / FIBER OPTIC
AutoCAD SHX Text
%%UELECTRIC
AutoCAD SHX Text
%%UGAS
AutoCAD SHX Text
%%UCOMMUNICATIONS / FIBER OPTIC
AutoCAD SHX Text
%%UTELEPHONE
AutoCAD SHX Text
%%UCOMMUNICATIONS / FIBER OPTIC
AutoCAD SHX Text
%%UWATER / SEWER / REUSE
AutoCAD SHX Text
%%USTORMWATER FORCE MAIN
AutoCAD SHX Text
GENERAL NOTES
WEST PARKING LOT IMPROVEMENTS
DAVID W. HAMSTRA, P.E.
REGISTRATION No. 38652
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.: DYC-22044
DWH
CADD
DWH
APRIL 2019
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
SHEET OF 17
RO
B
SU
LL
IV
AN
C
OM
MU
NI
TY
P
AR
K
W
ES
T
PA
RK
IN
G
LO
T
IM
PR
OV
EM
EN
TS
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
Fax. (407) 358-5155
Certificate of Authorization No. 27770
Office (407) 992-9160
Pegasus Engineering, LLC
PHOTOGRAPH #1 - EXISTING WEST PARKING LOT MAIN ENTRANCE
PHOTOGRAPH #2 - LOOKING NORTH TOWARDS EXISTING ROB SULLIVAN
PHOTOGRAPH #3 - LOOKING NORTH FROM SOUTH EDGE OF EXISTING
PHOTOGRAPH #4 - EXISTING SIDEWALK ACROSS PROPOSED WEST
PHOTOGRAPH #5 - VIEW LOOKING SOUTH TOWARDS EXISTING PARKING
FROM WEST HIGHBANKS ROAD.
PARKING LOT. NOTE PARK IRRIGATION MAIN AND VALVES.
PARKING LOT EXPANSION AREA (TO REMAIN).
LOT (EXISTING DRAINAGE INLET IN FOREGROUND).
0' 20'
1" = 20'
COMMUNITY PARK PARKING LOT FROM PARKING LOT EXPANSION AREA.
AutoCAD SHX Text O 18
AutoCAD SHX Text O 7
AutoCAD SHX Text O 3
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 6
AutoCAD SHX Text O 4
AutoCAD SHX Text O 4
AutoCAD SHX Text O 4
AutoCAD SHX Text O 6
AutoCAD SHX Text O 5
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 8
AutoCAD SHX Text O 4
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 5
AutoCAD SHX Text
SITE BENCHMARK
AutoCAD SHX Text
SET NAIL AND DISC
AutoCAD SHX Text
"SSMC TRAV PT"
AutoCAD SHX Text
ELEVATION=54.80
AutoCAD SHX Text
SITE BENCHMARK
AutoCAD SHX Text
SET NAIL AND DISC
AutoCAD SHX Text
IN CONCRETE WALL
AutoCAD SHX Text
"SSMC TRAV PT"
AutoCAD SHX Text
ELEVATION=43.85
AutoCAD SHX Text
INLET
AutoCAD SHX Text
TOP=44.40
AutoCAD SHX Text
NW INV=38.75
AutoCAD SHX Text
NE INV=38.73
AutoCAD SHX Text
INLET
AutoCAD SHX Text
TOP=54.78
AutoCAD SHX Text
SE INV=48.32
AutoCAD SHX Text
SW INV=48.37
AutoCAD SHX Text N=1657123.1900
AutoCAD SHX Text E=548833.3100
AutoCAD SHX Text N=1657158.0600
AutoCAD SHX Text E=549078.6500
AutoCAD SHX Text
PROPOSED CDBG IMPROVEMENTS
AutoCAD SHX Text
AERIAL LOCATION MAP AND
AutoCAD SHX Text
PHOTOGRAPHS OF EXISTING CONDITIONS
AutoCAD SHX Text
HIGHBANKS ROAD
AutoCAD SHX Text
EXISTING POND
AutoCAD SHX Text
1.80 ACRES
AutoCAD SHX Text
2.08 ACRES
AutoCAD SHX Text
0.22 AC
0.49 AC.
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.: DYC-22044
DWH
CADD
DWH
APRIL 2019
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
SHEET OF 17
RO
B
SU
LL
IV
AN
C
OM
MU
NI
TY
P
AR
K
W
ES
T
PA
RK
IN
G
LO
T
IM
PR
OV
EM
EN
TS
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
Fax. (407) 358-5155
Certificate of Authorization No. 27770
Office (407) 992-9160
Pegasus Engineering, LLC
AutoCAD SHX Text
APPARENT RIGHT OF WAY LINE
AutoCAD SHX Text
WEST HIGHBANKS ROAD
AutoCAD SHX Text
60' RIGHT OF WAY
AutoCAD SHX Text
(ASPHALT ROAD)
AutoCAD SHX Text
PER ORB 1878, PG 1485
AutoCAD SHX Text
SITE BENCHMARK SET NAIL AND DISC "SSMC TRAV PT" ELEVATION=54.80
AutoCAD SHX Text
SITE BENCHMARK SET NAIL AND DISC IN CONCRETE WALL "SSMC TRAV PT" ELEVATION=43.85
AutoCAD SHX Text
INLET TOP=44.40 NW INV=38.75 NE INV=38.73
AutoCAD SHX Text
24" ABS
AutoCAD SHX Text
18" ABS
AutoCAD SHX Text
15" ABS
AutoCAD SHX Text
INLET TOP=54.78 SE INV=48.32 SW INV=48.37
AutoCAD SHX Text
NOT PLATTED PARCEL ID: 29-18-30-00-00-0060 ROB SULLIVAN PARK ORB 5323, PG 3448
AutoCAD SHX Text
FOUND 1/2" "RLS3282"
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
COVERED CONCRETE
AutoCAD SHX Text
MULCH PLAYGROUND
AutoCAD SHX Text
CRUSHED ASPHALT PARKING
AutoCAD SHX Text
CRUSHED ASPHALT PARKING
AutoCAD SHX Text
ASPHALT PAVEMENT PARKING
AutoCAD SHX Text
ASPHALT PAVEMENT PARKING
AutoCAD SHX Text 4"x4" POST
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
EDGE OF PAVEMENT
AutoCAD SHX Text 4"x4" POST
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
POST & RAIL FENCE
AutoCAD SHX Text N=1657123.1900
AutoCAD SHX Text E=548833.3100
AutoCAD SHX Text N=1657158.0600
AutoCAD SHX Text E=549078.6500
AutoCAD SHX Text C:\Users\Michael\Documents\My Projects\PEG-017 Rob Sullivan West Park Parking Lot Expansion\Plans Production\SHEET-04 TOPOGRAPHIC SURVEY.dwg
AutoCAD SHX Text
TOPOGRAPHIC SURVEY
AutoCAD SHX Text
= POLYVINYL CHLORIDE PIPE
AutoCAD SHX Text
PVC
AutoCAD SHX Text
= ACRYLONITRILE BUTADIENE STYRENE PIPE
AutoCAD SHX Text
ABS
AutoCAD SHX Text
= BURIED CABLE LINE
AutoCAD SHX Text
-BCL-
AutoCAD SHX Text
AutoCAD SHX Text
= POST & RAIL FENCE
AutoCAD SHX Text
ORB
AutoCAD SHX Text
= OFFICIAL RECORDS BOOK
AutoCAD SHX Text
PG(S)
AutoCAD SHX Text
= PAGE(S)
AutoCAD SHX Text
= REGISTERED LAND SURVEYOR
AutoCAD SHX Text
RLS
AutoCAD SHX Text
INV
AutoCAD SHX Text
= INVERT
AutoCAD SHX Text
= TRAVERSE POINT
AutoCAD SHX Text
TRAV.PT.
AutoCAD SHX Text
= SOUTHEASTERN SURVEYING
AutoCAD SHX Text
SSMC
AutoCAD SHX Text
& MAPPING CORPORATION
AutoCAD SHX Text
SIZE SHOWN IS TRUNK DIAMETER IN INCHES MEASURED AT CHEST HEIGHT
AutoCAD SHX Text
= TREE
AutoCAD SHX Text NOTICE OF LIABILITY: This survey is certified to those individuals shown on the face thereof. Any other use, benefit or reliance by any other party is strictly prohibited and restricted. Surveyor is responsible only to those certified and hereby disclaims any other liability and hereby restricts the rights of any other individual or firm to use this survey, without express written consent of the surveyor.
AutoCAD SHX Text
%%ULEGEND & ABBREVIATIONS:
AutoCAD SHX Text
= TREE
AutoCAD SHX Text
= OAK
AutoCAD SHX Text O
AutoCAD SHX Text B
AutoCAD SHX Text
= BAY
AutoCAD SHX Text DESCRIPTION: A portion of Section 29, Township 18 South, Range 30 East, lying in Volusia County, Florida.
AutoCAD SHX Text
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text 1" = 30'
AutoCAD SHX Text
AutoCAD SHX Text 30'
AutoCAD SHX Text
AutoCAD SHX Text SURVEYOR'S REPORT: 1. Utility locations if shown hereon are based on field location of markings by utility company representatives, surface features and construction plans Utility locations if shown hereon are based on field location of markings by utility company representatives, surface features and construction plans furnished to the surveyor. Additional sub-surface utilities may exist that have not been field located. 2. Easements or rights of way that appear on recorded plans or that have been furnished to the surveyor by others have been incorporated into this drawing Easements or rights of way that appear on recorded plans or that have been furnished to the surveyor by others have been incorporated into this drawing with appropriate notation. Other easements may be discovered by a search of the Public Records. 3. Minimum Horizontal Accuracy for this survey is in accordance with the STANDARDS OF PRACTICE set forth by the Board of Professional Surveyors and Minimum Horizontal Accuracy for this survey is in accordance with the STANDARDS OF PRACTICE set forth by the Board of Professional Surveyors and Mappers in Chapter 5J-17 requirements of Florida Administration Code. The map and measurement methods used for this survey meet or exceed this requirement. The dimensions shown hereon are in United States survey feet and decimals thereof. 4. This survey does not determine ownership of the lands shown hereon. This survey does not determine ownership of the lands shown hereon. 5. Underground foundations have not been located. Underground foundations have not been located. 6. Survey map and report or the copies thereof are not valid without the signature and the original raised seal of a Florida Licensed Surveyor and Mapper. Survey map and report or the copies thereof are not valid without the signature and the original raised seal of a Florida Licensed Surveyor and Mapper. 7. Features shown by symbol as indicated in the legend are not to scale. Features shown by symbol as indicated in the legend are not to scale. 8. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 9. Horizontal features shown on the map refer to a National Geodetic Survey point with designation "ORANGE CITY RESET", PID number AK0077 and is relative Horizontal features shown on the map refer to a National Geodetic Survey point with designation "ORANGE CITY RESET", PID number AK0077 and is relative to North American Datum of 1983 (NAD83), 1990 adjustment, State Plane Coordinate System, Florida East Zone. Distances shown are GRID distances. 10. Vertical information shown hereon refers to a National Geodetic Survey (NGS) point with designation "ORANGE CITY RESET", PID number AK0077 and has a Vertical information shown hereon refers to a National Geodetic Survey (NGS) point with designation "ORANGE CITY RESET", PID number AK0077 and has a published elevation of 54.15 feet North American Vertical Datum of 1988 (NAVD88). 11. This Survey was performed without benefit of an abstract, title search, title opinion or title commitment. A title search may reveal additional information This Survey was performed without benefit of an abstract, title search, title opinion or title commitment. A title search may reveal additional information affecting the parcel as shown. 12. Improvements & Topographic features shown hereon are limited to areas per specific instructions of the client. Improvements & Topographic features shown hereon are limited to areas per specific instructions of the client. 13. Right of Way information shown hereon was determined by found monumentation, recorded plats, and information obtained on the Volusia County Property Right of Way information shown hereon was determined by found monumentation, recorded plats, and information obtained on the Volusia County Property Appraisers web site.
AutoCAD SHX Text E
AutoCAD SHX Text
= BURIED ELECTRIC PEDESTAL
AutoCAD SHX Text
= FLAT GRATE INLET
AutoCAD SHX Text
= IRON PIPE
AutoCAD SHX Text
= IRON ROD
AutoCAD SHX Text
IRR
AutoCAD SHX Text
= IRRIGATION VALVE
AutoCAD SHX Text
= LIGHT POLE
AutoCAD SHX Text
= NAIL W/DISC
AutoCAD SHX Text
= NON-TRAFFIC SIGN
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.: DYC-22044
DWH
CADD
DWH
APRIL 2019
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
SHEET OF 17
RO
B
SU
LL
IV
AN
C
OM
MU
NI
TY
P
AR
K
W
ES
T
PA
RK
IN
G
LO
T
IM
PR
OV
EM
EN
TS
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
Fax. (407) 358-5155
Certificate of Authorization No. 27770
Office (407) 992-9160
Pegasus Engineering, LLC
0' 40
1" = 40'
AutoCAD SHX Text O 18
AutoCAD SHX Text O 7
AutoCAD SHX Text O 3
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 6
AutoCAD SHX Text O 4
AutoCAD SHX Text O 4
AutoCAD SHX Text O 4
AutoCAD SHX Text O 6
AutoCAD SHX Text O 5
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 8
AutoCAD SHX Text O 4
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 5
AutoCAD SHX Text
SITE BENCHMARK
AutoCAD SHX Text
SET NAIL AND DISC
AutoCAD SHX Text
"SSMC TRAV PT"
AutoCAD SHX Text
ELEVATION=54.80
AutoCAD SHX Text
SITE BENCHMARK
AutoCAD SHX Text
SET NAIL AND DISC
AutoCAD SHX Text
IN CONCRETE WALL
AutoCAD SHX Text
"SSMC TRAV PT"
AutoCAD SHX Text
ELEVATION=43.85
AutoCAD SHX Text
INLET
AutoCAD SHX Text
TOP=44.40
AutoCAD SHX Text
NW INV=38.75
AutoCAD SHX Text
NE INV=38.73
AutoCAD SHX Text
INLET
AutoCAD SHX Text
TOP=54.78
AutoCAD SHX Text
SE INV=48.32
AutoCAD SHX Text
SW INV=48.37
AutoCAD SHX Text N=1657123.1900
AutoCAD SHX Text E=548833.3100
AutoCAD SHX Text N=1657158.0600
AutoCAD SHX Text E=549078.6500
AutoCAD SHX Text
SURVEY CONTROL
AutoCAD SHX Text STA. 205+84.84 - END CONST. CL CONST. PARKING LOT IMPROVEMENTS N. 1657117.0722 E. 548854.3070
AutoCAD SHX Text STA. 200+80.00 CL CONST. PARKING LOT IMPROVEMENTS= STA. 300+83.71-P.T. CL CONST. PARKING LOT ENTRANCE N. 1656614.7282 E. 548836.8166
AutoCAD SHX Text 100+00
AutoCAD SHX Text
STA. 300+00.00 CL CONST. PARKING LOT ENTRANCE N. 1656595.5136 E. 548772.0207
AutoCAD SHX Text STA. 300+23.21-P.C. CL CONST. PARKING LOT ENTRANCE N. 1656586.2319 E. 548793.2938
AutoCAD SHX Text
R=32.27' L=60.50' DELTA=107°25'25"CH=52.02' CB=N56°47'08"E
AutoCAD SHX Text STA. 202+00.00-P.I. CL CONST. PARKING LOT IMPROVEMENTS N. 1656734.3015 E. 548844.0442
AutoCAD SHX Text STA. 203+89.11-P.I. CL CONST. PARKING LOT IMPROVEMENTS N. 1656922.9614 E. 548831.1284
AutoCAD SHX Text STA. 204+42.78-P.I. CL CONST. PARKING LOT IMPROVEMENTS N. 1656978.6019 E. 548833.1176
AutoCAD SHX Text
STA. 200+00.00 CL CONST. PARKING LOT IMPROVEMENTS N. 1656535.0619 E. 548829.5174
AutoCAD SHX Text STA. 201+73.95-P.I. CL CONST. PARKING LOT IMPROVEMENTS N. 1656708.2896 E. 548845.3894
AutoCAD SHX Text STA. 202+85.80-P.I. CL CONST. PARKING LOT IMPROVEMENTS N. 1656819.9224 E. 548838.5924
AutoCAD SHX Text S 66°25'39.87"23.21'
AutoCAD SHX Text N 05°14'06.44"93.953'
AutoCAD SHX Text N 02°57'37.70"26.047'
AutoCAD SHX Text N 03°39'56.46"85.794'
AutoCAD SHX Text N 04°07'28.63"103.309'
AutoCAD SHX Text N 02°07'25.69"53.677'
AutoCAD SHX Text N 08°34'41.44"142.059'
AutoCAD SHX Text
EXIST. 3" IRRIGATION MAIN (TO REMAIN)
AutoCAD SHX Text
CL CONST. PARKING LOT ENTRANCE
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.: DYC-22044
DWH
CADD
DWH
APRIL 2019
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
SHEET OF 17
RO
B
SU
LL
IV
AN
C
OM
MU
NI
TY
P
AR
K
W
ES
T
PA
RK
IN
G
LO
T
IM
PR
OV
EM
EN
TS
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
Fax. (407) 358-5155
Certificate of Authorization No. 27770
Office (407) 992-9160
Pegasus Engineering, LLC
RAP
R
6"
8"
CURB TYPE D
Edge Of Pavt.
Top Of Curb
Gutter
PLAN
PROFILE
STRAIGHT END
CURB TYPE D TRANSITION
3'
Trans.
3'
Trans.
TYPE "B" STABILIZED SUBBASE
AutoCAD SHX Text
TYPICAL SECTIONS
AutoCAD SHX Text
WEST PARKING LOT IMPROVEMENTS
AutoCAD SHX Text
EXIST. GROUND
AutoCAD SHX Text
2% SLOPE
AutoCAD SHX Text
2% SLOPE
AutoCAD SHX Text
PROFILE GRADE POINT
AutoCAD SHX Text 25'
AutoCAD SHX Text 25'
AutoCAD SHX Text 6'
AutoCAD SHX Text 6'
AutoCAD SHX Text
12' DRIVING LANE
AutoCAD SHX Text
19' PARKING BAY
AutoCAD SHX Text
19' PARKING BAY
AutoCAD SHX Text
3" RECLAIMED ASPHALT PAVEMENT (RAP)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYPICAL SECTION
AutoCAD SHX Text
%%UWEST PARKING LOT IMPROVEMENTS
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
STA. 200+84.44 TO STA. 202+85.80
AutoCAD SHX Text
AutoCAD SHX Text
ONE WAY NORTHBOUND
AutoCAD SHX Text
VARIES (TO BE SODDED)
AutoCAD SHX Text
CONC. WHEEL STOP
AutoCAD SHX Text
CONC. WHEEL STOP
AutoCAD SHX Text
6" CONC. SIDEWALK
AutoCAD SHX Text 5'
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
3' (TYP.)
AutoCAD SHX Text 3'
AutoCAD SHX Text
1' (TYP.)
AutoCAD SHX Text
4:1 (TYP.)
AutoCAD SHX Text
4:1 (TYP.)
AutoCAD SHX Text
4:1 (TYP.)
AutoCAD SHX Text
2' (TYP.)
AutoCAD SHX Text
EXIST. GROUND
AutoCAD SHX Text
2% SLOPE
AutoCAD SHX Text
2% SLOPE
AutoCAD SHX Text
PROFILE GRADE POINT
AutoCAD SHX Text 25'
AutoCAD SHX Text 25'
AutoCAD SHX Text 6'
AutoCAD SHX Text 6'
AutoCAD SHX Text
12' DRIVING LANE
AutoCAD SHX Text
19' PARKING BAY
AutoCAD SHX Text
19' PARKING BAY
AutoCAD SHX Text
3" RECLAIMED ASPHALT PAVEMENT (RAP)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYPICAL SECTION
AutoCAD SHX Text
%%UWEST PARKING LOT IMPROVEMENTS
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
STA. 202+85.80 TO STA. 204+80.00
AutoCAD SHX Text
AutoCAD SHX Text
ONE WAY NORTHBOUND
AutoCAD SHX Text
VARIES (TO BE SODDED)
AutoCAD SHX Text
CONC. WHEEL STOP
AutoCAD SHX Text
CONC. WHEEL STOP
AutoCAD SHX Text
6" CONC. SIDEWALK
AutoCAD SHX Text 5'
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
3' (TYP.)
AutoCAD SHX Text 3'
AutoCAD SHX Text
1' (TYP.)
AutoCAD SHX Text
4:1 (TYP.)
AutoCAD SHX Text
4:1 (TYP.)
AutoCAD SHX Text
4:1 (TYP.)
AutoCAD SHX Text
2' (TYP.)
AutoCAD SHX Text EXIST. PARKING LOT (TO BE REMOVED, RAP MATERIAL TO BE SALVAGED AND REUSED AS MUCH AS POSSIBLE)
AutoCAD SHX Text
LIMITS OF EXIST. PARKING LOT (TO REMAIN)
AutoCAD SHX Text
LIMITS OF EXIST. PARKING LOT (TO REMAIN)
AutoCAD SHX Text SUBBASE: 12" TYPE "B" STABILIZED SUBBASE COMPACTED TO 98% DENSITY BASED ON AASHTO T-180 MODIFIED PROCTOR TEST WITH MINIMUM LBR 40
AutoCAD SHX Text SUBBASE: 12" SUBBASE COMPACTED TO 98% DENSITY BASED ON AASHTO T-180 MODIFIED PROCTOR TEST WITH MINIMUM LBR 40
AutoCAD SHX Text
BACKFILL
AutoCAD SHX Text
BACKFILL
AutoCAD SHX Text
SODDED SWALE
AutoCAD SHX Text
SODDED SWALE
AutoCAD SHX Text
3:1 (TYP.)
AutoCAD SHX Text
3:1 (TYP.)
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'
AutoCAD SHX Text
PROP. 6"X6" TIMBER POST AND RAIL (BY OTHERS)
AutoCAD SHX Text
1' (TYP.)
AutoCAD SHX Text
PROP. 6"X6" TIMBER POST AND RAIL (BY OTHERS)
AutoCAD SHX Text
1' (TYP.)
AutoCAD SHX Text
2% SLOPE
AutoCAD SHX Text
2% SLOPE
AutoCAD SHX Text
3" RECLAIMED ASPHALT PAVEMENT (RAP)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYPICAL SECTION
AutoCAD SHX Text
%%UWEST PARKING LOT IMPROVEMENTS - ENTRANCE DRIVEWAY
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
STA. 300+00.00 TO STA. 300+84.44
AutoCAD SHX Text SUBBASE: 12" TYPE "B" STABILIZED SUBBASE COMPACTED TO 98% DENSITY BASED ON AASHTO T-180 MODIFIED PROCTOR TEST WITH MINIMUM LBR 40
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ONE WAY NORTHBOUND
AutoCAD SHX Text
PROFILE GRADE POINT
AutoCAD SHX Text
24' (TYP.)
AutoCAD SHX Text
TYPE D CURB (SEE DETAILS, THIS SHEET)
AutoCAD SHX Text
TYPE D CURB (SEE DETAILS, THIS SHEET)
AutoCAD SHX Text
EXIST. GROUND
AutoCAD SHX Text
4:1 (TYP.)
AutoCAD SHX Text
2% SLOPE
AutoCAD SHX Text
2% SLOPE
AutoCAD SHX Text 6"
AutoCAD SHX Text
SOD
AutoCAD SHX Text
SOD
SOD
SIGNED AND SEALED
NOT A FINAL PLAN UNLESS
DATE:
APPROVED BY:
DRAWN BY:
DATE:
DESIGNED BY:
JOB No.: DYC-22044
DWH
CADD
DWH
APRIL 2019
DA
TE
RE
V.
DE
SC
RI
PT
IO
N
SHEET OF 17
RO
B
SU
LL
IV
AN
C
OM
MU
NI
TY
P
AR
K
W
ES
T
PA
RK
IN
G
LO
T
IM
PR
OV
EM
EN
TS
State of Florida Board of Professional Engineers
301 West SR 434, Suite 309 Winter Springs, Florida 32708
Fax. (407) 358-5155
Certificate of Authorization No. 27770
Office (407) 992-9160
Pegasus Engineering, LLC
0' 20'
Horizontal: 1" = 20' Vertical: 1" = 2'
AutoCAD SHX Text O 7
AutoCAD SHX Text O 3
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 6
AutoCAD SHX Text O 4
AutoCAD SHX Text O 4
AutoCAD SHX Text O 4
AutoCAD SHX Text O 6
AutoCAD SHX Text O 5
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 4
AutoCAD SHX Text O 4
AutoCAD SHX Text O 5
AutoCAD SHX Text O 5
AutoCAD SHX Text O 5
AutoCAD SHX Text
SITE BENCHMARK
AutoCAD SHX Text
SET NAIL AND DISC
AutoCAD SHX Text
IN CONCRETE WALL
AutoCAD SHX Text
"SSMC TRAV PT"
AutoCAD SHX Text
ELEVATION=43.85
AutoCAD SHX Text
INLET
AutoCAD SHX Text
TOP=44.40
AutoCAD SHX Text
NW INV=38.75
AutoCAD SHX Text
NE INV=38.73
AutoCAD SHX Text N=1657123.1900
AutoCAD SHX Text E=548833.3100
AutoCAD SHX Text
PLAN AND PROFILE
AutoCAD SHX Text
WEST PARKING LOT IMPROVEMENTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 21+00
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 25+00
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CORE BORE EXIST. INLET, CONNECT PROP. 18" RCP AND GROUT FILL OPENING
AutoCAD SHX Text STA. 300+00.00 CL CONST. ENTRANCE ROAD= BEGIN CONST. WEST PARKING LOT N. 1656595.5136 E. 548772.0207
AutoCAD SHX Text
R=32.27' L=60.50' DELTA=107°25'25"CH=52.02' CB=N56°47'08"E
AutoCAD SHX Text S66°25'40"E23.21'
AutoCAD SHX Text
STA. 300+23.21-PC CL CONST. ENTRANCE ROAD N. 1656586.2319 E. 548793.2938
AutoCAD SHX Text
STA. 300+83.71-PT CL CONST. ENTRANCE ROAD N. 1656614.7282 E. 548836.8168
AutoCAD SHX Text STA. 300+83.71 CL CONST. ENTRANCE ROAD= STA. 200+80.00 CL CONST. WEST PARKING LOT N. 1656614.7282 E. 548836.8168
AutoCAD SHX Text
REMOVE AND DISPOSE OF EXIST. 12" PVC CULVERT
AutoCAD SHX Text
EXIST. CONC. SIDEWALK (TO BE REMOVED AND REPLACED)
AutoCAD SHX Text S-200
AutoCAD SHX Text S-201
AutoCAD SHX Text S-202
AutoCAD SHX Text S-204
AutoCAD SHX Text S-203
AutoCAD SHX Text S-205
AutoCAD SHX Text S-206
AutoCAD SHX Text S-200
AutoCAD SHX Text S-202
AutoCAD SHX Text S-204
AutoCAD SHX Text S-206
AutoCAD SHX Text
EXISTING HANDICAPPED PARKING (TO REMAIN)
AutoCAD SHX Text
EXISTING CONC. SIDEWALK (TO REMAIN)
AutoCAD SHX Text
EXISTING CONC. SIDEWALK (TO REMAIN)
AutoCAD SHX Text
CONST. 46 LF OF 18" RCP
AutoCAD SHX Text
CONST. 34 LF OF 18" RCP
AutoCAD SHX Text
EXIST. TREE (TO REMAIN)
AutoCAD SHX Text
EXIST. TREE (TO BE REMOVED)
AutoCAD SHX Text
CONST. PT SPLIT RAIL FENCE (BY OTHERS, SEE DETAILS SHEET 15)
AutoCAD SHX Text
REMOVE AND RELOCATE EXISTING PR TIMBER FENCE (BY OTHERS)
AutoCAD SHX Text
REMOVE AND RELOCATE EXISTING PR TIMBER FENCE (BY OTHERS)
AutoCAD SHX Text
CONST. STRAIGHT END CURB TRANSITION (SEE DETAILS SHEET 6)
AutoCAD SHX Text
CONST. SODDED SWALE
AutoCAD SHX Text
EXIST. LIGHT POLE (TO BE RELOCATED BY OTHERS)
AutoCAD SHX Text
INV. EL. 43.00
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .