Camp Grayling bldg 8 drawings 1 of 2 - B&C.pdf
PDF 16 MB Posted
- Attached to
- 511/26081. CAK; Camp Grayling Building 8
- Solicitation number
- RFQ 171 260000000410 2
- Issued by
- Michigan
About this file
Camp Grayling Building 8 – Design and Construction Document Summary
This is a comprehensive set of architectural and engineering construction drawings for Building 8 at Camp Grayling, a military training facility in Grayling, Michigan, prepared by the State of Michigan Department of Technology, Management and Budget for the Department of Military and Veterans Affairs. The project encompasses the design and construction of a multi-functional building complex including a cold storage facility, work bays, wash bay, power washer room, offices, restrooms, mechanical spaces, and storage areas, with additional bid alternates for a salt/sand storage building and cold storage building expansion. The primary Building 8 measures approximately 240 feet in length and 100 feet in width with a finished floor elevation of 1,186.50 feet, featuring a pre-engineered metal building (PEMB) structural system with metal wall and roof panels, split-face concrete masonry unit (CMU) walls, and a 3-hour fire-rated barrier. The document set includes detailed floor plans, exterior elevations, building sections, wall details, reflected ceiling plans, site utility layouts, grading plans, and comprehensive specifications for structural, mechanical, plumbing, electrical, and fire protection systems. Three bid alternates are presented: Alternate #1 for vehicle service equipment (post lift, oil dispenser, tire machine), Alternate #2 for a concrete and asphalt apron expansion with additional mechanical equipment building, and Alternate #3 for a separate salt/sand storage building with approximately 63 feet by 34 feet dimensions.
The project was issued for bids and construction with a document date of July 22, 2026, prepared by Paradigm Design Architects in Grand Rapids, Michigan, with supporting engineering services provided by Matrix Consulting Engineers, Classic Engineering, Soils and Structures, and DCM Consulting. Site preparation involves demolition of existing asphalt, removal of gravel areas, and relocation of utilities including water, sanitary sewer, storm sewer, and gas service connections. The construction sequence indicates anticipated activity from January through December 2026, with rough grading, foundation work, building construction, and final landscaping phases. Significant site utility infrastructure improvements include a 262 linear foot 6-inch water line connection, 73-96 linear feet of 4-inch sanitary sewer installation with multiple cleanouts, and provision for tracer wire and warning tape above all subsurface utilities. The contractor assumes full responsibility for utility location verification, demolition permitting, soil erosion control compliance, and coordination with local utility companies and the Michigan EGLE requirements. Project management contact is Jon Jorgensen (DMVA Milcon Programming Manager) at 503-351-0830, with construction observations by Melissa Mead at 989-390-0763.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HELIPORT
W I L S O N
H
IL
L
P A R K
IN
G
A R E A
W I L S O N
H
IL
L
P A R K
IN
G
A R E A
PA
PA
PA
PA
PA
PA
PA
PA
W I L S
O N
H
IL
L
R
O A
D
REVIEW STAND
PA
PA
PA
PA
PA
PA
10/05
14"
4"
H
M
A
X-X-XX
MOST RECENT ISSUE DATE
MOST RECENT REVISION NUMBER
FILLED IN SQUARE INDICATES DRAWING
INCLUDED WITH THIS SET
SITE
LOCATION
M A
N
EO
M A
M A
L U
S N
I N
E P
S I
E R
E U
Q I
S
E C
I P
S M
U C
R I
C
M U
N U
S E
U B
I R
U L
P
SH
EE
T
SI
ZE
x
415 Leonard Street NW, Suite 200 Grand Rapids, MI 49504
(616) 785-5656 www.paradigmae.com
Grand Rapids | Phoenix
ARCHITECTS
PARADIGM DESIGN
ENGINEERS|
INTERIOR DESIGN
PROJECT DIRECTORY PROJECT LOCATION
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
S T
A T
E O
F M
IC
H
IG
A
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
D M
V A
P R
O
JE
C T
D
TM
B P
R O
JE
C
T
A R
C H
P R
O
JE
C T
R E
V
IS
IO
N
D E
S C
D
A
TE
D e p a rt m e n t o f
M ili ta ry a n d V e te ra n s A ff a ir s
C H
E C
K E
D
D R
A W
N
P .M
S
H E
E T
ID
E
N
TI
FI
C
A
TI
O N
N O
IS
S U
E D
F O
R D
A
TE
:1 :0
A M
BUILDING 8
CAMP GRAYLING, GRAYLING, MI
D M
V A
C A
M P
G R
A Y
L
IN
G B
U
IL
D
IN
G
COVER SHEET
C A
M P
G R
A Y
L
IN
G
G R
A Y
L
IN
G
M I
G -0
1/
1.
C
A K
0G
R
A ut ho r
C he ck er
PARADIGM DESIGN
ARCHITECT
415 LEONARD STREET NW, SUITE 200
GRAND RAPIDS, MI 49504
PHONE: 616-915-0724
EMAIL: TOCKASKIS@PARADIGMAE.COM
CONTACT: TODD OCKASKIS
MATRIX CONSULTING ENGINEERS
1601 E. CESAR E. CHAVEZ AVE.
LANSING, MI 48906
MECH/PLUMB ENGINEER
PHONE: 517-487-2511
CONTACT: ROSS WOLNIAKOWSKI, P.E.
EMAIL: RWOLNIAKOWSKI@MATRIXCEINC.COM
MATRIX CONSULTING ENGINEERS
1601 E. CESAR E. CHAVEZ AVE.
LANSING, MI 48906
ELECTRICAL ENGINEER
PHONE: 517-487-2511
CONTACT: MASON CORDES, P.E.
EMAIL: MCORDESI@MATRIXCEINC.COM
DCM CONSULTING
41000 WOODWARD AVE.
SUITE 350 EAST
BLOOMFIELD, MI 48304
COST ESTIMATING
PHONE: 248-933-6304
CONTACT: CHRIS TOMA
EMAIL: CHRIS.TOMA@DCMEST.COM
SOILS AND STRUCTURES
6480 GRAND HAVEN RD.
MUSKEGON, MI 49441
GEOTECH ENGINEER
PHONE: 248-568-8841
CONTACT: HANNA BARTON
EMAIL: HBARTON@SOILSANDSTRUCTURES.COM
CLASSIC ENGINEERING
100 CESAR E. CHAVEZ AVE. SW
SUITE 400
GRAND RAPIDS, MI 49503
STRUCTURAL ENGINEER
PHONE: 616-403-1433
CONTACT: KARIN KAPTEYN., P.E.
EMAIL: KKAPTEYN@CLASSICENGINEERING.COM
PARADIGM DESIGN
415 LEONARD ST. N.W. SUITE 200
GRAND RAPIDS, MI 49504
CIVIL ENGINEER
PHONE: 616-785-5656
CONTACT: ANA PELHANK, P.E.
EMAIL: APELHANK@PARADIGMAE.COM
NOT TO SCALE
LOCATION MAP
GENERAL
7-22-26 G-001 COVER SHEET
7-22-26 G-101 CODE DATA & LIFE SAFETY PLAN
CIVIL
7-22-26 C-101 EXISTING / DEMO SITE PLAN
7-22-26 C-102 LAYOUT AND UTILITY SITE PLAN
7-22-26 C-103 GRADING PLAN
7-22-26 C-501 SITE DETAILS
LANDSCAPE
7-22-26 L-101 LANDSCAPE PLAN
ARCHITECTURAL GENERAL INFORMATION
7-22-26 A-001 GENERAL INFORMATION
ARCHITECTURAL
7-22-26 A-101 OVERALL FLOOR PLAN
7-22-26 A-102 BID ALTERNATE PLANS
7-22-26 A-103 PEMB PLAN
7-22-26 A-161 FIRST FLOOR REFLECTED CEILING PLAN
7-22-26 A-201 EXTERIOR ELEVATIONS
7-22-26 A-202 BID ALTERNATE #3 EXTERIOR ELEVATIONS
7-22-26 A-301 BUILDING SECTIONS
7-22-26 A-302 EXTERIOR WALL SECTIONS
7-22-26 A-303 INTERIOR SECTIONS AND DETAILS
7-22-26 A-304 BID ALTERNATE #3 SALT/ SAND STORAGE BUILDING WALL
SECTIONS
STRUCTURAL GENERAL INFORMATION
7-22-26 S-001 STRUCTURAL NOTES
STRUCTURAL
7-22-26 S-101 FOUNDATION PLAN - BLDG 8
7-22-26 S-102 BLDG 8 FRAMING PLANS / SALT STORAGE STRUCTURAL PLANS
7-22-26 S-201 FOUNDATION DETAILS
7-22-26 S-202 FOUNDATION DETAILS
7-22-26 S-301 STRUCTURAL DETAILS
FIRE PROTECTION GENERAL INFORMATION
7-22-26 F-001 FIRE PROTECTION GENERAL INFORMATION
FIRE PROTECTION
7-22-26 F-101 FIRE PROTECTION FLOOR PLAN
PLUMBING GENERAL INFORMATION
7-22-26 P-001 PLUMBING GENERAL INFORMATION
PLUMBING
7-22-26 P-101 PLUMBING BELOW FLOOR PLAN
7-22-26 P-102 PLUMBING FLOOR PLAN
7-22-26 P-401 PLUMBING ENLARGED PLANS
7-22-26 P-601 PLUMBING DETAILS
7-22-26 P-602 PLUMBING SCHEDULES
CLIENT
DEPARTMENT OF MILITARY AND VETERANS AFFAIRS
CAMP GRAYLING, GRAYLING MI
PHONE: 503-351-0830
CONTACT: JON JORGENSEN
EMAIL: JORGENSENJ@MICHIGAN.GOV
MILCON PROGRAMMING MANAGER
DMVA CONSTRUCTION OBSERVATIONS
PHONE: 989-390-0763
CONTACT: MELISSA MEAD
EMAIL: MEADM4@MICHIGAN.GOV
MECHANICAL GENERAL INFORMATION
7-22-26 M-001 MECHANICAL GENERAL INFORMATION
MECHANICAL
7-22-26 M-101 MECHANICAL FLOOR PLAN
7-22-26 M-102 BID ALTERNATE #3 STORAGE BUILDING
7-22-26 M-401 MECHANICAL ENLARGED PLAN
7-22-26 M-601 MECHANICAL DETAILS
7-22-26 M-602 MECHANICAL SCHEDULES
ELECTRICAL GENERAL INFO
7-22-26 E-001 ELECTRICAL GENERAL INFORMATION
ELECTRICAL SITE
7-22-26 ES101 ELECTRICAL SITE PLAN - LIGHTING
ELECTRICAL LIGHTING
7-22-26 EL101 ELECTRICAL FLOOR PLAN - LIGHTING
7-22-26 EL102 BID ALTERNATE #2 & #3 STORAGE BUILDING
ELECTRICAL POWER
7-22-26 EP101 ELECTRICAL FLOOR PLAN - POWER
ELECTRICAL
7-22-26 E-501 ELECTRICAL RISER DIAGRAM
7-22-26 E-502 ELECTRICAL SCHEDULES
7-22-26 E-601 ELECTRICAL DETAILS
SHEET INDEX
B
ID
S
C O
N S
T R
U C
T
IO
N
-2
-2
EXIT SEPARATION = 128' - 0" > 102' MIN.
116' M
AX. D
IA
GONAL x
1/2 =
58' M
IN
. E
XIT S
EPARATIO
N D
ISTANCE
139' M
AX. D
IAGONAL x 1/3 =
46' M
IN. E
XIT SEPARATION DISTANCE
EXIT SEPARATION = 109' - 6" > 58' MIN.
EXIT NO.
DOOR NO.
ALLOWED:
ACTUAL:
CLR WIDTH:
101E
32.5"
TRAVEL DISTANCE = 84'-6"
EXIT NO.
DOOR NO.
ALLOWED:
ACTUAL:
CLR WIDTH:
103H
32.5"
EXIT NO.
DOOR NO.
ALLOWED:
ACTUAL:
CLR WIDTH:
103A
32.5"
EXIT NO.
DOOR NO.
ALLOWED:
ACTUAL:
CLR WIDTH:
103E
32.5"
EXIT NO.
DOOR NO.
ALLOWED:
ACTUAL:
CLR WIDTH:
101D
32.5"
3-HR FIRE BARRIER
PER UL U907
FIRE
AREA 1
FIRE
AREA 2
FEFE
FE
FEFE
FIRE EXTINGUISHER
LEGEND AND NOTES
NOTES:
1. CONTRACTOR TO VERIFY FINAL TYPES, SIZES, AND
LOCATIONS OF FIRE EXTINGUISHERS WITH LOCAL
FIRE AUTHORITIES.
2. TOP OF FIRE EXTINGUISHER MOUNTING BRACKET TO
BE 3'-6" A.F.F.
3. CONTRACTOR TO PROVIDE ALL FIRE EXTINGUISHERS
AND RELATED SIGNAGE.
4. REFER TO FLOOR PLAN FOR FIRE EXTINGUISHER
LOCATIONS.
SYMBOL DESCRIPTION
FE FIRE EXTINGUISHER - ON WALL MOUNTING
BRACKET WITH RETAINING STRAP
M A
N
EO
M A
M A
L U
S N
I N
E P
S I
E R
E U
Q I
S
E C
I P
S M
U C
R I
C
M U
N U
S E
U B
I R
U L
P
SH
EE
T
SI
ZE
x
415 Leonard Street NW, Suite 200 Grand Rapids, MI 49504
(616) 785-5656 www.paradigmae.com
Grand Rapids | Phoenix
ARCHITECTS
PARADIGM DESIGN
ENGINEERS|
INTERIOR DESIGN
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
S T
A T
E O
F M
IC
H
IG
A
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
D M
V A
P R
O
JE
C T
D
TM
B P
R O
JE
C
T
A R
C H
P R
O
JE
C T
R E
V
IS
IO
N
D E
S C
D
A
TE
D e p a rt m e n t o f
M ili ta ry a n d V e te ra n s A ff a ir s
C H
E C
K E
D
D R
A W
N
P .M
S
H E
E T
ID
E
N
TI
FI
C
A
TI
O N
N O
IS
S U
E D
F O
R D
A
TE
TODD OCKASKIS
MI - REGISTRATION # 1301051301
EXP. DATE - 4/30/2027
:4 :4
P M
D M
V A
C A
M P
G R
A Y
L
IN
G B
U
IL
D
IN
G
CODE DATA & LIFE SAFETY PLAN
C A
M P
G R
A Y
L
IN
G
G R
A Y
L
IN
G
M I
G -1
1/
1.
C
A K
0G
R
A ut ho r
C he ck er
N
SCALE: 1/16" = 1'-0"
LIFE SAFETY PLAN
B
ID
S
C O
N S
T R
U C
T
IO
N
-2
-2
STM
WTR
WTR
WTR
WTR
WTR
WTR WTR WTR WTR
WTR
SANSAN
STM
STM
STM
STM
STM
STM
ST
M
ST
M
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
ST
M
ST
M
ST
M
ST
M
STM
ST
M
G
G
G
G G G
G G
G G
G G
G
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
WTR WTR
WTR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
WTR
WTR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
G
G
G
G
G
G
G G
G
G
G
G
G
G G
G G
G G
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
UG-E
U G
-E U
G -E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E U
G -E
U G
-E U
G -E
U G
-E
UG-E
U G
-E
U G
-E
U G
-E
UG-E
UG-E
UG-E
UG-E
UG-E
UG-E
U G
-E
UG
-E
UG
-E
U G
-E
U G
-E
UG-EUG-EUG-EUG-EUG-E
UG-E
UG-E
UG-E
UG-E
UG-E UG-E
UG
-E
U G
-E
U G
-E U
G -E
U G
-E U
G -E
U G
-E U
G -E
U G
-E
UG-E
UG-E
UG-E
G G
G
G
G
G G
GENERAL KEYNOTES:
FV FIELD VERIFY SIZE, LOCATION, AND DEPTH OF UTILITY.
XP EXISTING ITEM TO REMAIN. PROTECT FROM
CONSTRUCTION ACTIVITIES.
DEMOLITION LEGEND
REMOVE EXISTING ASPHALT
APPROXIMATELY 70' OF EX. FOUNDATION
WALL AND FOOTINGS BURIED 2' +- BELOW
EXISTING GRADE TO REMAIN.
DEMO FOUNDATION AS REQUIRED.
APPROXIMATELY 50' OF EX. FOUNDATION
WALL AND FOOTINGS BURIED 2' +- BELOW
EXISTING GRADE TO REMAIN.
DEMO FOUNDATION AS REQUIRED.
EX. ROUND CATCH BASIN
EX. 15' x 30' GRAVEL AREA.
REMOVE EX. GRAVEL AS REQUIRED
TO PROVIDE THE PROPOSED BASE AND
ASPHALT. (DETAIL 1/C-102)
EX. TRENCH DRAIN TO REMAIN
ASPHALT TO BE REMOVED. GC TO VERIFY
EXTENT OF REMOVAL TO BUILD LOW
ASPHALT HUMP TO FLOW WATER TO EX.
TRENCH DRAIN.
10' x 60' DAMAGED ASPHALT AND SOIL. FIELD VERIFY
EXTENT OF DAMAGED ASPHALT AREA.
EX. SAN MH
TO REMAIN
PARADIGM DESIGN
415 Leonard Street NW, Suite 200 Grand Rapids, MI 49504
(616) 785-5656
ENGINEERSARCHITECTS
JOB #2603020 GR
SH
EE
T
SI
ZE
x
MA
N
EO
MA
MA
L
US
N
I N
EP
S
IERE
U
Q
IS
E C
I P
S M
U C
R I
C
MUN
U
S E
UB I R U L P
0G R
1/
1.
C
AK
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
ST
A
TE
O
F M
IC
H
IG
A
N D
EP
A
R
TM
EN
T
O F
TE
C
H N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
DM
VA
P
RO
JE
C T
DT
M B P
RO
JE
C T
AR
C H P
RO
JE
C T
RE
VI
SI
ON
D
ES
C
DA
TE
D e p a rt m e n t o f M ili ta ry a n d
V e te ra n s A ff a ir s
AP
PR
OV
ED
SH
EE
T
C H
EC
KE
D
ID
EN
TI
FI
C
AT
IO
N
NO
DR
AW
N
IS
SU
ED
F
OR
P.
M
DA
TE
D M V A
C A M P
G R A Y
LI
N G
B U
IL
D
IN
G
C A M P
G R A Y
LI
N G G R A Y
LI
N G M I
B
ID
S C
ON
ST
RU
C
TI
ON
T.
O.
C
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY
PIPES, CONDUITS OR STRUCTURES SHOWN ON THESE PLANS WAS
OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY
AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE
CONTRACTOR SHALL POTHOLE ALL EXISTING UTILITIES TO VERIFY
THE LOCATION AND ANY DISCREPANCY BETWEEN THE PLANS
SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER.
C .N
XP
XP
XP
XP
XP
XP
XP
XP XP
XP
XP
FV
FV
XP
EX. RETAINING WALL
TO REMAIN.
XP
EX. TRENCH DRAIN
TO REMAIN.
XP
ASPHALT TO BE REMOVED.
XP
XP
EX. RETAINING WALL
TO REMAIN.
XP
EX. SIDEWALK TO
REMAIN.
EX. COMMUNICATION
STRUCTURE TO
REMAIN.
XP
EX. ELECTRICAL
BOXES TO REMAIN
XP
EX. ELECTRICAL BOXES
TO REMAIN
EX. CATCH BASIN
TO REMAIN
REMOVE BROKEN CONCRETE
BLOCKS AT END OF CONCRETE WALL
EXISTING BUILDING #7
CONCRETE TO
BE REMOVED
BID ALTERNATE 3: ASPHALT
TO BE REMOVED.
EX. EDGE OF ASPHALT
EXISTING CONDITIONS AND
DEMOLITION PLAN
0 30' 60'
N
GRAVEL
DEMOLITION NOTES:
GENERAL: REFERENCE SECTION 31 1000-SITE CLEARING AND SECTION 31 2000-EARTHWORK OF PROJECT MANUAL.
ALL MATERIAL THAT IS NOT SUITABLE AS BACKFILL AND MATERIALS THAT ARE EXCESS SHALL BE SPREAD AND UTILIZED
WITHIN THE SITE. NO SOIL CAN LEAVE THE SITE.
ALL AREAS OF UNDERGROUND DEMOLITION; UTILITY LINE REMOVAL; AND UNDERGROUND TREE, STUMP, AND VEGETATION
REMOVAL SHALL BE BACKFILLED.
BACKFILLING SHALL PROMPTLY FOLLOW UNDERGROUND DEMOLITION OR REMOVAL WORK AND SHALL CONTINUE AS THE
DEMOLITION PROGRESSES.
CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING FOR AND OBTAINING ALL NECESSARY DEMOLITION PERMITS AND
PAYING FOR ANY ASSOCIATED PERMIT FEES.
CONTRACTOR TO CONTACT MIKE HALCOMB (DMVA) AT (989) 344-6184 AND MISS DIG FOR LOCATING EXISTING
UNDERGROUND UTILITIES.
NOTIFY ARCHITECT/ENGINEER OF ANY OTHER UNDERGROUND MATERIALS OR EQUIPMENT ENCOUNTERED DURING
EXCAVATION NOT SPECIFICALLY NOTED ON THE DRAWING(S).
PRIVATE UTILITY REMOVAL - CONTRACTOR TO COORDINATE PRIVATE UTILITY (GAS, ELECTRIC, PHONE, CABLE, ETC.)
REMOVAL WITH DMVA. ALTHOUGH ALL PRIVATE UTILITY SERVICES MAY NOT BE SHOWN ON THIS DRAWING, CONTRACTOR
IS RESPONSIBLE FOR REMOVAL OF SERVICE AS NECESSARY.
WHERE CURBING OR PAVEMENT IS INDICATED TO BE REMOVED, IT SHALL BE SAWCUT FULL DEPTH. REMOVE TO THE NEAREST JOINT, IF THE JOINT IS WITHIN 3 FEET OF THE REMOVAL LINE. VERIFY REMOVAL LIMITS WITH ENGINEER PRIOR
TO BEGINNING WORK.
XP
XP
EX.GRASS
EXISTING
BUILDING #30
SAW CUT & REMOVE ASPHALT FOR
NEW WATER CONNECTION
106.41'
85.83'
64.77'
69.09' 76.48'
XP
XP
REMOVE EXISTING GRAVEL
JON W. LEDY
MI - REGISTRATION #6201038734
EXP. DATE 03/12/2028
AutoCAD SHX Text www.paradigmae.com
AutoCAD SHX Text Grand Rapids | Phoenix
AutoCAD SHX Text C-101 apelhank Jon's Seal
WTR
WTR
WTR
WTR
WTR WTR WTR WTR
WTR
SANSANSANSANSAN
STM
STM
STM
STM
STM
STM
ST
M
ST
M
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
ST
M
ST
M
ST
M
ST
M
STM
ST
M
G G
G G
M
G
G
G
G G G
G G
G G
G G
G G
M
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
CO
WTR WTR
WTR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
WTR
WTR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
G
G
G
G
G
G
G G
G
G
G
G
G
G G
G G
G
G
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
UG-E
U G
-E U
G -E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E U
G -E
U G
-E U
G -E
U G
-E
UG-E
U G
-E
U G
-E
U G
-E
UG-E
UG-E
UG-E
UG-E
UG-E
U G
-E
UG
-E
UG
-E
U G
-E
U G
-E
UG-EUG-EUG-EUG-EUG-E
UG-E
UG-E
UG-E
UG-E
UG-E
UG-E UG-E
UG
-E
U G
-E U
G -E
U G
-E U
G -E
U G
-E U
G -E
U G
-E U
G -E
U G
-E
UG-E
UG-E
UG-E
UG-E
UG-E
UG-E
CO
CO
CO
CO
G G
G
G
G
COCO
SANSAN
CO
CO
CO
CO
CO
G
G G
0 20' 40'
PARADIGM DESIGN
415 Leonard Street NW, Suite 200 Grand Rapids, MI 49504
(616) 785-5656
ENGINEERSARCHITECTS
JOB #2603020 GR
M A
N E O
MA
MA
L U S
N
IN
E P
S
IERE
U Q
IS
E C
I P
S M
U C
R I
C
MUN
U
S E
UB I R U L P
0G R
1/
1.
C
AK
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
ST
A
TE
O
F M
IC
H
IG
A
N D
EP
A
R
TM
EN
T
O F
TE
C
H N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
DM
VA
P
RO
JE
C T
DT
M B P
RO
JE
C T
AR
C H P
RO
JE
C T
RE
VI
SI
ON
D
ES
C
DA
TE
D e p a rt m e n t o f M ili ta ry a n d
V e te ra n s
A ff a ir s
AP
PR
OV
ED
SH
EE
T
C H
EC
KE
D
ID
EN
TI
FI
C
AT
IO
N
NO
DR
AW
N
IS
SU
ED
F
OR
P.
M
DA
TE
D M V A
C A M P
G R A Y
LI
N G
B U
IL
D
IN
G
C A M P
G R A Y
LI
N G G R A Y
LI
N G M I
B
ID
S C
ON
ST
RU
C
TI
ON
T.
O.
C
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY
PIPES, CONDUITS OR STRUCTURES SHOWN ON THESE PLANS WAS
OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY
AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE
CONTRACTOR SHALL POTHOLE ALL EXISTING UTILITIES TO VERIFY
THE LOCATION AND ANY DISCREPANCY BETWEEN THE PLANS
SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER.
C .N
PROPOSED LEGEND
PROPOSED LANDSCAPE
PROPOSED
LANDSCAPE AREA.
SEE LANDSCAPE PLAN.
HO
W
E
RD
BEAVER CREEK RD
BEAVER CREEK RD
HO
W
E
RD
EXISTING WATERWTR
PROPOSED GRAVEL PARKING AREA
EX. ELECTRICAL BOXES
EX. ELECTRICAL BOXES
BID ALTERNATE 2: CONCRETE
AND ASPHALT
EX. SAN. MANHOLE
CONNECT EX.
SIDEWALK TO
GRAVEL PATH
APROX. 10' x 60' NEW ASPHALT AREA. FIELD
VERIFY EXTENT OF DAMAGED ASPHALT.
SEE DETAIL 1/C-501.
APROX. 15' x 30' NEW ASPHALT AREA. FIELD
VERIFY EXTENT OF GRAVEL AREA. SEE
DETAIL 1/C-501.
ASPHALT TO BE REMOVED. GC TO
VERIFY EXTENT OF REMOVAL TO
BUILD ASPHALT HUMP TO DIRECT
WATER TO EX. TRENCH DRAIN.
EX. TRENCH DRAIN
UNCOVER EXISTING CATCH BASIN.
GRADE BACK ON 1:4 TO EXISTING
GRADE. REPLACE FRAME & GRATE
WITH MDOT 1020 COVER, TYPE 2.
34'
PROPOSED
BUILDING 8SS
F.F. = 1191.90
EX. TRENCH DRAIN
R75'
R50'
R40'
R20'
BID ALTERNATE 2: COLD STORAGE
BUILDING ADDITION
EXISTING BUILDING #7
GENERAL NOTES:
REFER TO ARCHITECTURAL PLANS FOR DETAILS OF CONCRETE DOOR STOOPS, AND WALLS.
REFER TO ARCHITECTURAL PLAN FOR DETAILING OF BUILDING AND EXACT BUILDING DIMENSIONS.
REFER TO LANDSCAPE PLAN FOR RESTORATION OF ALL NON PAVED SURFACES.
REFER TO SECTION 311000 OF THE PROJECT MANUAL FOR SITE CLEARING WORK.
REFER TO SECTION 312000 FOR EARTH MOVING.
REFER TO SECTION 315000 OF THE PROJECT MANUAL FOR EXCAVATION SUPPORT AND PROTECTION OF EXISTING
UTILITIES AND STRUCTURES.
REFER TO PROJECT MANUAL FOR SITE "RECORD DRAWING" SUBMITTAL REQUIREMENTS.
IF FILL IS REQUIRED, CONTRACTOR CAN OBTAIN FILL FROM SITE IN AREA 600. REFER TO FILL LOCATION MAP THIS SHEET.
PROVIDE POSITIVE DRAINAGE AT ALL TIMES TO ENSURE NO STANDING WATER WITHIN PAVEMENT, BUILDING PAD, OR
GREEN AREAS.
RESTORE ALL STREETS, SURFACES, DRIVEWAYS, CULVERTS, ROADSIDE DITCHES, AND OTHER STRUCTURES THAT ARE DISTURBED OR DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITIES TO MATCH EXISTING CONDITIONS AT A MINIMUM.
CONTRACTOR IS RESPONSIBLE TO OBTAIN ALL SITE RELATED PERMITS. CONTRACTOR IS REQUIRED TO COMPLETE THE APPLICATION, AND SUBMIT NECESSARY DRAWINGS, FEES, ETC. TO THE APPROPRIATE JURISDICTION. CONTRACTOR SHALL
PAY ALL FEES RELATED TO PERMIT(S) AND SECURE PERMIT(S) IN HIS NAME.
CONTRACTOR TO CONTACT MIKE HALCOMB (DMVA) AT (989) 344-6184 AND MISS DIG FOR LOCATING EXISTING
UNDERGROUND UTILITIES.
CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL SITE UTILITY CONNECTIONS AND INSPECTIONS WITH THE PROPER
JURISDICTION AND PAY ALL ASSOCIATED FEES.
THE CONTRACTOR SHALL FIELD VERIFY LOCATION AND ELEVATION OF EXISTING WATER, SANITARY SEWER, AND STORM SEWER CROSSINGS AND CONNECTION POINTS PRIOR TO CONSTRUCTION. CONTACT ENGINEER WITH ANY
DISCREPANCIES.
REFERENCE SOILS REPORT FOR BORING LOGS AND PREPARATION AND CONSTRUCTION PROCEDURES FOR SUBBASE AND
DESIGN SECTION OF ALL PAVED AREAS.
GENERAL PRIVATE UTILITY NOTES:
PROPOSED PRIVATE UTILITY SERVICE AS SHOWN IS SCHEMATIC ONLY. ACTUAL LOCATION TO BE COORDINATED WITH
INDIVIDUAL UTILITY COMPANY AND APPROVED BY OWNER.
CONTRACTOR SHALL COORDINATE LOCATION OF ALL PRIVATE UTILITIES (GAS, ELECTRIC, PHONE, CABLE, ETC.) WITH THE LOCAL UTILITY COMPANIES AND THE MECHANICAL DRAWINGS. COORDINATE ALL PRIVATE UTILITY LOCATIONS WITH ALL
SUB-SURFACE SITE UTILITIES SHOWN ON THIS PLAN.
CONTRACTOR TO PROVIDE TRACER WIRE AND WARNING TAPE ABOVE ALL SITE
UTILITIES. REFER TO ELECTRICAL SHEET FOR EXTENT OF ELECTRICAL UTILITIES
NOT SHOW ON THIS SHEET.
BID ALTERNATE 3: SALT/SAND
STORAGE BUILDING
SITE AND UTILITY
LAYOUT PLAN
EXTEND CONCRETE TO BE
LEVEL WITH FIRST TREAD
OF EXISTING STEPS
EXISTING SANITARY SEWERSAN
EXISTING STORM SEWERSTM
ROUND CATCH BASIN
EXISTING GASG
EX. COMMUNICATION
STRUCTURE TO REMAIN.
CONNECT NEW GAS SERVICE TO
EXISTING GAS MAIN. COORDINATE
FINAL LOCATION AND INSTALLATION
REQUIREMENTS WITH GAS UTILITY.
APPROXIMATE LOCATION OF
EX. SANITARY SEWER STUB.
CONTRACTOR TO FIELD VERIFY
PRIOR TO CONSTRUCTION.
EX. CB REPLACE FRAME & GRATE
WITH MDOT 1020 COVER, TYPE 2.
GENERAL SANITARY SEWER NOTES:
SITE CONTRACTOR TO END SANITARY LATERAL 5' FROM BUILDING WITH A CLEAN-OUT AND TEMPORARY CAP.
COORDINATE CONNECTION WITH BUILDING PLUMBING CONTRACTOR.
REFER TO SECTION 333100 FOR FACILITY SANITARY SEWERS.
SANITARY SEWER LATERALS AND FITTINGS SHALL BE PVC PER ASTM D3034, SDR26. JOINTS TO BE ELASTOMERIC
SEALS IN ACCORDANCE WITH ASTM F477.
MATERIALS, INSTALLATION, AND TESTING OF SANITARY SEWER SHALL CONFORM TO COUNTY STANDARDS.
ALL SANITARY SEWER WORK SHALL COMPLY WITH THE MICHIGAN PLUMBING CODE, EGLE REQUIREMENTS, LOCAL UTILITY STANDARDS, AND DMVA PROJECT REQUIREMENTS. CONTRACTOR SHALL PROVIDE TESTING DOCUMENTATION INCLUDING LEAKAGE TESTING, DEFLECTION TESTING, AND INSPECTION REPORTS PRIOR TO
ACCEPTANCE.
ALL UTILITY TRENCHING SHALL BE AS PER DETAIL #5/C-501.
GENERAL WATER SERVICE NOTES:
SITE CONTRACTOR TO END WATER & FIRE SERVICES 12" ABOVE FINISHED FLOOR INSIDE BUILDING WITH A TEMPORARY CAP.
COORDINATE CONNECTION WITH BUILDING PLUMBING CONTRACTOR.
MINIMUM DEPTH OF BURY SHALL BE 5.5'.
MATERIALS, INSTALLATION, AND TESTING OF WATER SERVICE LINES SHALL CONFORM WITH CAMP GRAYLING STANDARDS
AND THE STATE PLUMBING CODE.
WATER MAIN SHALL BE AWWA C900 OR C909 PVC, DR18, EXCEPT AS OTHERWISE REQUIRED BY AHJ.
IRRIGATION WATER SERVICE TO BE SOURCED OFF WATER SERVICE INSIDE BUILDING, COORDINATE WITH LANDSCAPER AND
PLUMBING ENGINEER.
SITE
SOURCE LOCATION OF FILL
FOR BLDG 8 PROJECT
FILL LOCATION MAP
EXISTING GRASS AREA
PROPOSED WATER
PROPOSED SANITARY SEWER
PROPOSED GASG
30' 34'
EXISTING
BUILDING #30
PROPOSED BUILDING 8X
F.F. = 1186.50
±262 L.F. 6" WATER LINE
REFER TO DETAIL 5/C-501.
CONTRACTOR TO PROVIDE 2' WIDE X 2"
RIGID POLYSTYRENE INSULATION
ABOVE PIPE AT DRIVE.
4" WYE
EL: ±1182.78
IE: ±1177.78
30° BEND &
CLEAN OUT
IE: ±1182.50
CLEAN OUT
IE: 1182.45
96 LF 4" SANITARY SEWER @ 4.18%
CONTRACTOR TO PROVIDE 2' WIDE X 2" RIGID
POLYSTYRENE INSULATION ABOVE PIPE AT DRIVE.
EXISTING STORM SYSTEM
EX. CO.
EL: 1182.02
IE: ±1177.02
22'
90 L.F. GAS
SERVICE
PROPOSED 6" WATER LINE CONNECTION TO EXISTING 6" WATER MAIN BY TAPPING
SLEEVE AND VALVE. CONTRACTOR SHALL FIELD VERIFY THE EXISTING WATER
MAIN LOCATION, SIZE, MATERIAL, AND CONDITION PRIOR TO CONSTRUCTION.
MAINTAIN EXISTING WATER SERVICE AND COORDINATE THE TAP AND ANY
REQUIRED SHUTDOWN WITH THE UTILITY OWNER.
139'
76'
170.6'
63'
5'
5'
PARKING BOLLARD (REFER TO DETAIL 4/A-302)
SANITARY CLEAN OUT (REFER TO DETAIL 13/C-501)CO
SEE PLUMBING PLAN
FOR CONTINUATION
39.27'
REFER TO SHEET A-101 FOR
CONCRETE DIMENSIONS
PROPOSED CONCRETE SIDEWALK (REFER TO DETAIL 3/C-501)
PROPOSED HEAVY DUTY BITUMINOUS (REFER TO DETAIL 1/C-501)
PROPOSED LANDSCAPE STONE BED (REFER TO DETAIL 11/C-501)
PROPOSED HEAVY DUTY CONCRETE APRON
(REFER TO DETAIL 2/C-501)
BID ALTERNATE 2: LANDSCAPE
STONE AND BORDER REFER
TO DETAIL 11/C-501
C-501
C-501
C-501
30° BEND &
CLEAN OUT
EL: ±1183.30
IE: ±1177.50
IE IN: 1182.40
30° BEND &
CLEANOUT
IE: 1182.18
73 LF 4" SANITARY
SEWER @ ±6.02%
IE OUT: 1182.23
5'
±5'5'
15 LF 4" SANITARY
SEWER @ 1.00%
DETAILED SANITARY SEWER SERVICE INSET
0 30' 60'
N
SEE PLUMBING PLANS
FOR CONTINUATION
IE: 1182.50
OIL / WATER SEPARATOR
REFER TO DETAIL 11/C-502
5 LF 4" SANITARY SEWER @ 4.18%
SEE PLUMBING PLANS
FOR CONTINUATION
IE: 1182.50
EXISTING END
OF LINE
LANDSCAPE STONE AREA.
REFER TO DETAIL 11/C-501.
SEE INSET BELOW
LANDSCAPE STONE AREA.
REFER TO DETAIL 4/C-501.
PROPOSED GRAVEL PAVEMENT (REFER TO DETAIL 4/C-501)
APPROXIMATELY 70' OF EX.
FOUNDATION
WALL AND FOOTINGS BURIED 2' +-
BELOW EXISTING GRADE TO REMAIN.
DEMO FOUNDATION AS REQUIRED.
APPROXIMATELY 50' OF EX. FOUNDATION
WALL AND FOOTINGS BURIED 2' +- BELOW
EXISTING GRADE TO REMAIN.
DEMO FOUNDATION AS REQUIRED.
6" - 90° BEND
JON W. LEDY
MI - REGISTRATION #6201038734
EXP. DATE 03/12/2028
AutoCAD SHX Text www.paradigmae.com
AutoCAD SHX Text Grand Rapids | Phoenix
AutoCAD SHX Text C-102
WTR
WTR
WTR
WTR
WTR WTR WTR WTR
WTR
SANSANSANSANSAN
STM
STM
STM
STM
STM
STM
ST
M
ST
M
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
ST
M
ST
M
ST
M
ST
M
STM
ST
M
G G
G G
M
G
G
G
G
G G G
G G
G G
G G
G G
G
M
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SA
N
SA
N
SA
N
CO
WTR WTR
WTR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
WTR
WTR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
G
G
G
G
G
G
G G
G
G
G
G
G G
G G
G
G
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
STM
UG-E
U G
-E U
G -E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E
U G
-E U
G -E
U G
-E U
G -E
U G
-E
UG-E
U G
-E
U G
-E
U G
-E
UG-E
UG-E UG-E
UG-E
UG-E
UG-E
UG-E
UG-E
UG-E
U G
-E
UG
-E
UG
-E
UG
-E
UG-E
U G
-E
UG-EUG-EUG-EUG-EUG-E
UG-E
UG-E
UG-E
UG-E
UG-E
UG-E UG-E
UG
-E
U G
-E U
G -E
U G
-E U
G -E
U G
-E U
G -E
U G
-E U
G -E
U G
-E
UG-E
UG-E
UG-E
UG-E
UG-E
CO
CO
CO
CO
G G
G
G
G
G G
G
G
G
1182.41 MX
1182.50 MX
1181.69 MX
1184.53 MX
1187.46 MX
1184.98 MX
1185.31 MX
1184.89 MX
1190.62 MX1190.43 MX
1190.63 MX
1192.03 MX
1190.69 CON/BIT 1191.12 CON/BIT
1191.49 MX
2.77%
4.99%
5.86%
2.16%
0.75% 2.38%
2.55%
0.50%
6.0 0%
0.64%
1.5 0%
1191.81 BIT-BW
1193.37 TW
1192.87 FG
1191.90 CON-BW
1194.30 TW
1193.80 FG
1186.50 CON
1186.31 CON
1186.36 CON
1186.45 CON1186.35 CON
1186.40 FG
1186.26 CON
1186.26 CON
1186.26 CON
1185.54 CON
1185.66 CON
1185.79 CON
1185.07 MX
1185.42 CON/BIT
1185.34 MX
1186.35 CON
1186.45 CON
1186.48 CON
1186.45 CON
1186.45 CON
1186.13 CON
1186.00 FG
1185.02 RIM
1184.60 RIM
2.0 4%
98 1199
82 11 83 118
86 1187
1186.40 CON
1186.00 FG
1186.00 FG
1186.45 CON
4.84%
4:1
4:1
1186.00 FG
1186.31 CON
1186.31 CON
1186.31 CON
1186.51 CON
1186.48 CON
1186.48 CON
1186.48 CON
1186.48 CON
1186.50 CON
1186.50 CON
1186.50 CON
1186.31 CON
1186.31 CON
3:1
1191.80 FG
1194 1195 1196
1191.38 FL
1194.29 FL
1195.41 FG
1192.48 FL
1186.31 CON
0 30' 60'
N
PARADIGM DESIGN
415 Leonard Street NW, Suite 200 Grand Rapids, MI 49504
(616) 785-5656
ENGINEERSARCHITECTS
JOB #2603020 GR
M A
N E O
MA
MA
L U S
N
IN
E P
S
IERE
U Q
IS
E C
I P
S M
U C
R I
C
MUN
U
S E
UB I R U L P
0G R
1/
1.
C
AK
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
ST
A
TE
O
F M
IC
H
IG
A
N D
EP
A
R
TM
EN
T
O F
TE
C
H N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
DM
VA
P
RO
JE
C T
DT
M B P
RO
JE
C T
AR
C H P
RO
JE
C T
RE
VI
SI
ON
D
ES
C
DA
TE
D e p a rt m e n t o f M ili ta ry a n d
V e te ra n s
A ff a ir s
AP
PR
OV
ED
SH
EE
T
C H
EC
KE
D
ID
EN
TI
FI
C
AT
IO
N
NO
DR
AW
N
IS
SU
ED
F
OR
P.
M
DA
TE
D M V A
C A M P
G R A Y
LI
N G
B U
IL
D
IN
G
C A M P
G R A Y
LI
N G G R A Y
LI
N G M I
B
ID
S C
ON
ST
RU
C
TI
ON
T.
O.
C
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY
PIPES, CONDUITS OR STRUCTURES SHOWN ON THESE PLANS WAS
OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY
AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE
CONTRACTOR SHALL POTHOLE ALL EXISTING UTILITIES TO VERIFY
THE LOCATION AND ANY DISCREPANCY BETWEEN THE PLANS
SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER.
C .N
SF SF
SF
SF
SF
SFSFSFSFSFSFSFSF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
HYDRO-SEED UNDER EROSION
6 CONTROL BLANKET
PAVING
GEOTEXTILE INLET FILTER
GEOTEXTILE SILT FENCE
UNIFIED KEYING SYSTEM
SOIL EROSION AND SEDIMENTATION CONTROL MEASURES
GENERAL CONTRACTOR SHALL COMPLETE CONSTRUCTION SEQUENCE SCHEDULE
WHEN MAKING APPLICATION FOR SOIL EROSION CONTROL PERMIT.
YEAR: 2026
LANDSCAPING
FINISH GRADING
SITE CONSTRUCTION
FOUNDATION / BUILDING CONSTRUCTION
PERMANENT CONTROL MEASURES
TEMPORARY CONSTRUCTION ROADS
STORM UTILITIES
TEMPORARY CONTROL MEASURES
ROUGH GRADING SEDIMENT CONTROL
STRIPPING & STOCKPILING TOPSOIL
JA
N
FE
B.
M
AR
AP
R
M
AY
JU
N
E
JU
LY
AU
G
SE
P.
O C
T.
N O
V.
D
EC
.CONSTRUCTION SEQUENCE
NOTE: CONTRACTOR IS TO SWEEP STREET IMMEDIATELY
SHOULD SEDIMENT FROM SITE BE TRACKED ONTO
STREET. PROVIDE CATCH BASIN INLET FILTERS AS
NECESSARY WITHIN STREET AND DOWNSTREAM OF SITE.
CAUTION GAS LINE
FLAMMABLE MATERIAL
NOTE: ALL UTILITIES SHOWN ARE APPROXIMATE
LOCATIONS FROM FIELD DATA AND AVAILABLE
INFORMATION. THEY SHOULD NOT BE INTERPRETED
AS EXACT LOCATIONS NOR SHOULD THEY BE
ASSUMED TO BE THE ONLY UTILITIES IN THE AREA.
55 T
55 T
55 T
55 T
55 T
55 T
55 T
54 T
54 T
54 T
54 T
54 T
WTR
SAN
STM
G
G
HYDRO-SEEDING
6 P
6 P
6 P
7 P
7 P
55 T
55 T
55 T
7 P
7 P
15 P
7 P
15 P
15 P
15 P
55 T
7 P
15 T
HO
W
E
RD
BEAVER CREEK RD
BEAVER CREEK RD
HO
W
E
RD
PROPOSED ASPHALT HUMP
CONTRACTOR TO FIELD VERIFY EXTENT
REQUIRED TO DIRECT WATER TOWARD
TRENCH DRAIN WEST OF THIS LOCATION
EXISTING BUILDING #7
EXISTING INLET
RIM EL. 1184.20
PROPOSED GRAVEL PARKING AREA
PROPOSED SWALE
PROPOSED SWALE
PROPOSED RETAINING WALL
SEE STRUCTURAL PLANS
EXISTING INLET
RIM EL. 1183.47
RAISE FINISH GRADE
TO TOP OF EXISTING
BOTTOM TREAD
EX. COMMUNICATION
STRUCTURE TO REMAIN.
MEET & MATCH EX. GRADE
PROPOSED LEGEND
ROUND CATCH BASIN
SILT FENCE (REFER TO DETAIL 8/C-501)
GRADING PLAN
EXISTING
BUILDING #30
PROPOSED
BUILDING 8SS
F.F. = 1191.90
PROPOSED BUILDING 8X
F.F. = 1186.50
EXISTING STORM
GENERAL SOIL EROSION AND SEDIMENTATION CONTROL NOTES:
IT IS THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN THE SOIL EROSION PERMIT FROM THE PROPER GOVERNING
AUTHORITY.
A CONTRACTOR / INSPECTOR SHALL INSPECT THE SOIL EROSION/SEDIMENT CONTROL DEVICES ONCE EACH WEEK AND/OR WITHIN 24 HOURS OF A PRECIPITATION EVENT WHICH RESULTS IN A STORM DISCHARGE FROM THE SITE.
ALL DISTURBED NON-PAVEMENT AREAS MUST BE RESTORED WITH TOPSOIL, SEED, FERTILIZER, AND MULCH UNLESS
SODDED.
ALL SLOPES STEEPER THAN 1V:3H SHALL USE AN EROSION CONTROL BLANKET (NORTH AMERICAN GREEN S150BN OR EQUAL). ALL SLOPES BETWEEN 1V:4H AND 1V:3H SHALL USE AN EROSION CONTROL BLANKET (NORTH AMERICAN GREEN
DS75 OR EQUAL). UNLESS INDICATED OTHERWISE ON PLANS.
SEEDING SHOULD BE PREPARED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. THE CONTRACTOR / INSPECTOR SHALL INSPECT THE AREA AFTER SEEDING IS COMPLETED. AREAS THAT ARE BARE OR NOT MULCHED
PROPERLY WILL NEED TO BE SPOT SEEDED AND/OR RE-MULCHED.
SILT FENCE SHOULD BE TRENCHED IN, BACKFILLED, AND STAPLED OR STAKED ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS. MAINTENANCE INCLUDES THE REMOVAL OF BUILT-UP SEDIMENT WHEN THE SEDIMENT ACCUMULATES TO 1/3 TO 1/2 THE HEIGHT OF THE FENCE. CONTRACTOR SHALL REMOVE, REPLACE, RETRENCH, OR REBACKFILL THE FENCE IF IT FAILS. CONTRACTOR SHALL REINSTALL IF ANY PORTION OF THE FENCING IS DAMAGED BY CONSTRUCTION
MACHINERY.
INLET FILTERS SHALL BE SILT SACKS, DANDY BAGS, OR APPROVED EQUAL. INLET FILTERS SHALL BE INSPECTED FOR BUILDUP OF SILT AND OTHER DEBRIS. THIS IS EVIDENT IF STRUCTURE IS CAUSING FLOODING. MAINTENANCE SHALL
CONSIST OF REMOVING OF SEDIMENTS OR REPLACING FILTER AS NECESSARY.
SOIL EROSION CONTROL METHODS SHOWN ARE A GUIDELINE AND DO NOT RELIEVE THE CONTRACTOR FROM ADDITIONAL
METHODS THAT MAY BE REQUIRED BY THE SOIL EROSION CONTROL PERMIT.
THE CONTRACTOR WILL ENGAGE A CERTIFIED STORM WATER OPERATOR IN ACCORDANCE WITH EPA PHASE II RULES TO MEET REQUIREMENTS OF THE PERMIT. THIS OPERATOR WILL INSPECT THE JOB SITE AS REQUIRED BY RULE, NOTIFY JOB SITE SUPERINTENDENT OF ANY DEFICIENCIES, AND ENTER FINDINGS IN THE JOB SITE INSPECTION JOB BOOK.
SITE SOILS CONSIST OF FINE TO COURSE GRAINED SAND WITH VARYING AMOUNT OF SILT AND GRAVEL PER SITE
GEO-TECHNICAL REPORT COMPLETED BY SOIL & STRUCTURES DATED MAY 13, 2026.
TOTAL DISTURBED AREA = 1.21 ACRES.
SURFACE FLOW ARROW PROPOSED SPOT GRADE675.00 FG
BITUMINOUS GRADE
CONCRETE GRADE
SIDEWALK GRADE
STRUCTURE RIM ELEVATION
MATCH EXISTING ELEVATION
TOP OF CURB GRADE
FLOW LINE GRADEFL
TC
CON
MX
SW
BIT
RIM
FINISHED GROUNDFG
SILT FENCE @ TOE OF SLOPE
REFER TO DETAIL 8/C-501.
SILT FENCE @ TOE OF SLOPE
INLET PROTECTION
INLET
PROTECTION CAUTION - CRITICAL
UTILITY
CAUTION - CRITICAL
UTILITY
BID ALTERNATE 3: SALT/SAND
STORAGE BUILDING
EXISTING WATER
EXISTING SANITARY SEWER
EXISTING STORM SEWER
EXISTING GAS
PROPOSED WATER
PROPOSED SANITARY SEWER
PROPOSED GAS
PROPOSED CONCRETE SIDEWALK (REFER TO DETAIL 3/C-501)
PROPOSED HEAVY DUTY BITUMINOUS (REFER TO DETAIL 1/C-501)
PROPOSED LANDSCAPE STONE BED (REFER TO DETAIL 11/C-501)
PROPOSED HEAVY DUTY CONCRETE APRON (REFER TO
DETAIL 2/C-501)
CONC. WASH OUT AREA
SEE DETAIL 6/C-501
MAINTENANCE AND INSPECTIONS:
A. AT A MINIMUM, PROCEDURES IN A SWP3 SHALL PROVIDE THAT CONTROLS ON THE SITE ARE INSPECTED AT LEAST ONCE EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS AFTER ANY STORM EVENT GREATER THAN ONE-HALF INCH OF RAIN PER 24-HOUR PERIOD. AN INSPECTOR CHECKLIST MUST BE COMPLETED AND SIGNED BY THE INSPECTOR AFTER EVERY SWP3 INSPECTION. THE INSPECTION CHECKLIST FREQUENCY MAY BE REDUCED TO AT LEAST ONCE EVERY MONTH FOR DORMANT SITES IF THE ENTIRE SITE IS TEMPORARILY STABILIZED OR RUNOFF IS UNLIKELY DUE TO WEATHER CONDITIONS FOR EXTENDED PERIODS OF TIME (E.G., SITE IS COVERED WITH SNOW, ICE, OR THE GROUND IS FROZEN).
THE BEGINNING AND ENDING DATES OF ANY REDUCED INSPECTION FREQUENCY SHALL BE MARKED ON THE SWP3 AND NO FURTHER INSPECTION REQUIREMENTS SHALL APPLY TO THAT PORTION OF THE SITE.
B. IF THE INSPECTION REVEALS THAT A CONTROL PRACTICE IS IN NEED OR REPAIR OR MAINTENANCE, WITH THE EXCEPTION OF A SEDIMENT SETTLING POND, IT MUST BE REPAIRED OR MAINTAINED WITHIN THREE DAYS OF THE INSPECTION. SEDIMENT SETTLING PONDS MUST BE REPAIRED OR MAINTAINED WITHIN 10
DAYS OF THE INSPECTION.
C. IF THE INSPECTION REVEALS THAT A CONTROL PRACTICE FAILS TO PERFORM ITS INTENDED FUNCTION AND THAT ANOTHER, MORE APPROPRIATE CONTROL PRACTICE IS REQUIRED, THE SWP3 MUST BE AMENDED AND THE NEW CONTROL PRACTICE MUST BE INSTALLED WITHIN 10 DAYS OF INSPECTION
D. IF THE INSPECTION REVEALS THAT A CONTROL PRACTICE HAS NOT YET BEEN IMPLEMENTED IN ACCORDANCE WITH THE SWP3 SCHEDULE, THE CONTROL PRACTICE MUST BE IMPLEMENTED WITHIN 10 DAYS FROM THE DATE OF INSPECTION. IF THE INSPECTION REVEALS THAT THE PLANNED CONTROL PRACTICE IS NOT NEEDED, THE RECORD MUST CONTAIN A STATEMENT OF EXPLANATION AS TO WHY THE
CONTROL PRACTICE IS NOT NEEDED.
E. INSPECTION RECORDS NEED TO BE KEPT FOR 3 YEARS AFTER TERMINATION OF THE CONSTRUCTION
ACTIVITIES.
* (SEE DETAIL #9/C-501)
OIL/WATER SEPARATOR. REFER TO
DETAIL 11/C-502. GC TO USE GRADE
ADJUSTED RINGS AS NEEDED.
REFER TO DETAIL 12/C-502.
GRADE TO PROVIDE POSITIVE
DRAINAGE TOWARD CATCH BASIN
PROPOSED GRAVEL PAVEMENT (REFER TO DETAIL 4/C-501)
JON W. LEDY
MI - REGISTRATION #6201038734
EXP. DATE 03/12/2028
AutoCAD SHX Text www.paradigmae.com
AutoCAD SHX Text Grand Rapids | Phoenix
AutoCAD SHX Text C-103
PARADIGM DESIGN
415 Leonard Street NW, Suite 200 Grand Rapids, MI 49504
(616) 785-5656
ENGINEERSARCHITECTS
JOB #2603020 GR
M A
N E O
MA
MA
L U S
N
IN
E P
S
IERE
U Q
IS
E C
I P
S M
U C
R I
C
MUN
U
S E
UB I R U L P
0G R
1/
1.
C
AK
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
ST
A
TE
O
F M
IC
H
IG
A
N D
EP
A
R
TM
EN
T
O F
TE
C
H N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
DM
VA
P
RO
JE
C T
DT
M B P
RO
JE
C T
AR
C H P
RO
JE
C T
RE
VI
SI
ON
D
ES
C
DA
TE
D e p a rt m e n t o f M ili ta ry a n d
V e te ra n s
A ff a ir s
AP
PR
OV
ED
SH
EE
T
C H
EC
KE
D
ID
EN
TI
FI
C
AT
IO
N
NO
DR
AW
N
IS
SU
ED
F
OR
P.
M
DA
TE
D M V A
C A M P
G R A Y
LI
N G
B U
IL
D
IN
G
C A M P
G R A Y
LI
N G G R A Y
LI
N G M I
B
ID
S C
ON
ST
RU
C
TI
ON
T.
O.
C
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY
PIPES, CONDUITS OR STRUCTURES SHOWN ON THESE PLANS WAS
OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY
AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE
CONTRACTOR SHALL POTHOLE ALL EXISTING UTILITIES TO VERIFY
THE LOCATION AND ANY DISCREPANCY BETWEEN THE PLANS
SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER.
C .N
NOT TO SCALE
UTILITY TRENCH5
TR
EN
CH
A
RE
A
(D
EP
TH
V
AR
IE
S)
SP
EC
IA
L
FO
UN
DA
TI
ON
AR
EA
BE
DD
IN
G
AR
EA
TRENCH WIDTH
AT UTILITY PIPE CROWN
PER SPECIFICATIONS
CROWN
UTILITY PIPE
SPRING LINE
INVERT
UNDISTURBED
GROUND
SITE DETAILS
NOT TO SCALE
CONCRETE SIDEWALK3
1V:48H CROSS-SLOPE (OR FLATTER)
6" AGGREGATE (21AA) OR
6" CLEAN SAND (MDOT CLASS II)
REFER TO THE GEOTECHNICAL ENGINEERING REPORT PREPARED BY SOILS &
STRUCTURES DATED MAY 13, 2026
NOT TO SCALE
HEAVY DUTY CONCRETE
PAVEMENT SECTION2
GRANULAR FILL OR
SUITABLE SUBGRADE
12" AGGREGATE (21AA) OR
12" CLEAN SAND (MDOT CLASS II)
REFER TO STRUCTURAL PLANS FOR
CONCRETE SLAB DESIGN
REFER TO THE GEOTECHNICAL ENGINEERING REPORT PREPARED BY SOILS &
STRUCTURES DATED MAY 13, 2026
NOT TO SCALE
HEAVY DUTY BITUMINOUS
PAVEMENT SECTION1
12" SAND SUB BASE
(MDOT CLASS II)
2.5 " HMA WEARING COURSE - 4EML
10" 21 AA CRUSHED LIME STONE
2.5 " HMA BASE COURSE - 4EML
COMPACTED
SUBGRADE TO 95%
RELATIVE
COMPACTION
PAVEMENT SECTION PER SOILS AND STRUCTURES GEOTECHNICAL
REPORT FOR CAMP GRAYLING MISSION TRAINING CENTER DATED
MAY 13, 2026
8'
MI
N
8' MIN
STAKE (TYP)
10 MIL PLASTIC LINING
STRAW BALE (TYP)
INSPECTION & MAINTENANCE:
1. CLEAN OUT WASHOUT AREA WHEN IT IS 75% FULL
2. REPLACE ANY DAMAGED OR MISSING HAY BALES OR OTHER FILTERING DEVICES
3. PROPERLY DISPOSE OF ANY HARDENED CONCRETE
" M
IN
A A
SECTION A-A
NOT TO SCALE
CONCRETE WASHOUT AREA6
PLAN VIEW
UNDISTURBED VEGETATION
SPACING 6' MAX.
SECTION A-A
SECTION B-B
SILT FENCE B
SILT FENCE JOINT
SILT FENCE A
1'- 0"
M
IN
FRONT VIEW
A
A
SHEET FLOW
SILT FENCE
B
SILT FENCE
A
GEOTEXTILE FILTER FABRIC
2'- 0"
M
IN
NOT TO SCALE
SILT FENCE8
6" ANCHOR TRENCH
1'- 0"
M
IN
GEOTEXTILE FILTER FABRIC
FASTENED ON UPHILL SIDE,
TOWARDS EARTH DISRUPTION
RIDGE COMPACTED EARTH ON
UPHILL SIDE OF FILTER FABRIC
6" x 6" ANCHOR TRENCH
UNDISTURBED
VEGETATION
COUPLER
FABRIC TO BE WRAPPED
AROUND FENCE POST
SUPPORT
FENCE
FENCE POSTS DRIVEN INTO
GROUND 1' MIN.
GEOTEXTILE FILTER
FABRICSUPPORT FENCE
SILT FENCE JOINT
SECTION B-B
SHEET
FLOW
SHEET
FLOW
COMPACTED EARTH
FENCE POSTS
NOT TO SCALE
INLET FILTER9
SUPPORT SYSTEM
WITH LIFT HANDLES
OVERFLOW AREA
FINISHED GRADE
GRATECASTING
SEDIMENT
BAG / FILTER
INLET STRUCTURE
6"
1'- 6"
NOT TO SCALE
DELIVERY SLAB EDGE7
8" CONC. SLAB EDGE
PAVING PER DRAWING
NOT TO SCALE
STONE BED11
FINISHED FLOOR = 1186.50
BUILDING WALL
12" WIDE CORRUGATED
METAL LANDSCAPE EDGING.
1" REVEAL OVER STONE
6" U
NO
GEO TEXTILE
5'-0"
6" THICK - 3/4" - 1/2"
LANDSCAPE STONE
4" CONC. SLAB INTEGRAL POUR
W/ 6x6, W1.4xW1.4 WWM
NOT TO SCALE
GRAVITY SEWER CLEAN-OUT10
12"
PAVED AREASIN LAWN AREAS
GRADE
6" THREADED CAP
WITH 1" SQUARE
OPERATING NUT
EJIW 1575 CASTING
24" DIA. CONCRETE
COLLAR 8" THICK
6" THREADED CAP WITH 1" SQUARE
OPERATING NUT OR 6" RUBBER
SPIGOT PLUG WITH WING NUT.
PEA STONE
6" RISER PIPE
6" 45° BEND
D" GRAVITY SEWER
D" X 6" WYE IF REQ'D
6" 45° BEND OR D" X 6" WYE
D"
12" AGGREGATE (21AA) OR
12" CLEAN SAND (MDOT CLASS II)
REFER TO STRUCTURAL
FOR CONCRETE APRON
CONSTRUCTION
NOT TO SCALE
GRAVEL SECTION4
12" OF GRANULAR FILL OR
SUITABLE SUBGRADE
10" AGGREGATE BASE MDOT 22A
PROVIDE CONTINUOUS TRACER WIRE
DIRECTLY ABOVE AND SECURED TO
PIPE. PROVIDE WARNING TAPE 12" TO
18" ABOVE THE PIPE.
PLACE 2' x 2" RIGID POLYSTYRENE
INSULATION 6" ABOVE UTILITY WHERE
NOTED ON PLANS
AutoCAD SHX Text www.paradigmae.com
AutoCAD SHX Text Grand Rapids | Phoenix
AutoCAD SHX Text C-501
MARCH 2016
020C - 104 SITE DETAILS.DWG
www.oldcastleprecast.com ©
24"Ø, 30"Ø & 36"Ø (I.D.)
GRADE RINGS
MANHOLES
GRADE RINGS
NOT TO SCALE
GRADE ADJUSTMENT RINGS12
PARADIGM DESIGN
415 Leonard Street NW, Suite 200 Grand Rapids, MI 49504
(616) 785-5656
ENGINEERSARCHITECTS
JOB #2603020 GR
M A
N
EO
MA
MA
L
US
N
IN
E P
S
IERE
U Q
IS
E C
I P
S M
U C
R I
C
MUN
U
S E
UB I R U L P
0G R
1/
1.
C
AK
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
ST
A
TE
O
F M
IC
H
IG
A
N D
EP
A
R
TM
EN
T
O F
TE
C
H N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
DM
VA
P
RO
JE
C T
DT
M B P
RO
JE
C T
AR
C H P
RO
JE
C T
RE
VI
SI
ON
D
ES
C
DA
TE
D e p a rt m e n t o f M ili ta ry a n d
V e te ra n s A ff a ir s
AP
PR
OV
ED
SH
EE
T
C H
EC
KE
D
ID
EN
TI
FI
C
AT
IO
N
NO
DR
AW
N
IS
SU
ED
F
OR
P.
M
DA
TE
D M V A
C A M P
G R A Y
LI
N G
B U
IL
D
IN
G
C A M P
G R A Y
LI
N G G R A Y
LI
N G M I
B
ID
S C
ON
ST
RU
C
TI
ON
T.
O.
C
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY
PIPES, CONDUITS OR STRUCTURES SHOWN ON THESE PLANS WAS
OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY
AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE
CONTRACTOR SHALL POTHOLE ALL EXISTING UTILITIES TO VERIFY
THE LOCATION AND ANY DISCREPANCY BETWEEN THE PLANS
SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER.
C .N
SITE DETAILS
NOT TO SCALE
WATER / OIL SEPARATOR11
AutoCAD SHX Text
FILE NAME:
AutoCAD SHX Text
REVISED:
AutoCAD SHX Text Copyright
AutoCAD SHX Text Northern California Madera Morgan Hill Pleasanton Santa Rosa Stockton Tulare Phone: 925-750-6650 Fax: 925-750-6660
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING MAY NOT CONFORM TO THE MOST CURRENT SPECIFICATION
AutoCAD SHX Text
36" GRADE RING3603 GRADE RING WEIGHT: 210 LBS 3606 GRADE RING WEIGHT: 420 LBS
AutoCAD SHX Text
30" GRADE RING3003 GRADE RING WEIGHT: 180 LBS 3006 GRADE RING WEIGHT: 360 LBS
AutoCAD SHX Text
24" GRADE RING2403 GRADE RING WEIGHT: 120 LBS 2406 GRADE RING WEIGHT: 240 LBS
AutoCAD SHX Text
3" OR 6"
AutoCAD SHX Text
3" OR 6"
AutoCAD SHX Text
3" OR 6"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 5"
AutoCAD SHX Text 3'-6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 3'-6"
AutoCAD SHX Text www.paradigmae.com
AutoCAD SHX Text Grand Rapids | Phoenix
AutoCAD SHX Text C-502
DETAIL / SECTION TITLE
PLAN TITLE
LEVEL / ELEVATION INDICATOR
ROOM NAME TAG
DOOR TAG
GLAZING TAG
CEILING TYPE & ELEVATION
ELEVATION A.F.F.
WALL CONSTRUCTION TAG
LEVEL NAME
X' - X"
A 0'-0"
COLUMN LABEL (NEW)
TYPE
ELEVATION TAG
BUILDING SECTION
ENLARGED PLAN / DETAIL CALLOUT
MATCH LINE
COLUMN LABEL (EXISTING)
MATCH LINE - SEE SHEET XXXX
POINT ELEVATION (PLAN)
POINT ELEVATION
(ELEVATION / SECTION)
SPOT COORDINATE
N X' - X" E X' - X"
REVISION TAG
INTERIOR FINISH TAG
TRANSITION IDENTIFICATION
ELEVATION TAG
X' - X"
WALL SECTION
DETAIL SECTION
TEMPERED GLASS
ARCHITECTURAL SYMBOLS
TOILET ACCESSORY TAG
T
# EXITING OCCUPANCY#
NUMBER OF
OCCUPANTS FOR EXIT
ARROW SHOWING
DIRECTION OF
EGRESS
N
SCALE: 1/8" = 1'-0"
VIEW TITLE
SCALE: 1/8" = 1'-0"
VIEW TITLE#
SHEET
SHEET
SIM
SIM
SIM
SIM
SHEET
DET #
DET #
DET #
SHEET
DET #
SHEET
DET #
SHEET
DET #
SHEET
X' - X"
X' - X"
ROOM
NAME
COLUMN LABEL (FUTURE)# #
TYPE
NUMBER
# DEMOLITION TAG
3.02 SECTION & DETAIL TAG
# FLOOR PLAN TAG & EXTERIOR
MATERIAL TAG
TA-#
ARCHITECTURAL ABBREVIATIONS
A M
ADJ ADJUSTABLE
ADD ADDENDUM
AFF ABOVE FINISHED FLOOR
ALUM ALUMINUM
APPROX APPROXIMATE
MFR MANUFACTURER
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOLDING
MO MASONRY OPENING
B
BD BOARD
BF BARRIER FREE
BLK BLOCK
BLKG BLOCKING
BLDG BUILDING
BO BOTTOM OF
BP BUMP POST
BRG BEARING
BULL BULLETIN
C
CAB CABINET
CLG CEILING
CL CENTERLINE
CT CERAMIC TILE
CLR CLEAR
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CJ CONTROL JOINT
CORR CORRIDOR
CMU CONCRETE MASONRY UNIT
CSMU CONCRETE SILICATE MASONRY UNIT
EA EACH
EIFS EXTERIOR INSULATING FINISH SYSTEM
ELEC ELECTRICAL
EL ELEVATION (GRADE)
ENCL ENCLOSURE
EQ EQUAL
EQUIP EQUIPMENT
EPS EXPANDED POLYSTYRENE
EXH EXHAUST
EXIST EXISTING
EXT EXTERIOR
EJ EXPANSION JOINT
EWC ELECTRIC WATER COOLER
E
FIN FINISH
FF FINISH FLOOR
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHC FIRE HOSE CABINET
FLR FLOOR
FD FLOOR DRAIN
FS FLOOR SINK
FTG FOOTING
FDN FOUNDATION
FP FIRE PROTECTION
FRT FIRE RETARDANT TREATED
FV FIELD VERIFY
F
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERAL
GPRFS GEOFOAM PERMANENT RISER
FORMING SYSTEM
GYP GYPSUM BOARD
G
HD HUB DRAIN
HT HEIGHT
HORIZ HORIZONTAL
HVAC HEATING-VENTILATION-AIR CONDITIONING
HSS HOLLOW STEEL SECTION
H
INSUL INSULATION
INT INTERIOR
I
JB JUNCTION BOX
J
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
O
OC ON CENTER
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
OH OVERHEAD
P
PR PAIR
PEMB PRE-ENGINEERED METAL BUILDING
PART PARTITION
PLYWD PLYWOOD
PLAM PLASTIC LAMINATE
PROP PROPERTY
PL PLATE
PVC POLYVINYL CHLORIDE
PT POINT
PVT PAVEMENT
Q
QTY QUANTITY
R
R RISER
RAD RADIUS
REF REFERENCE
REFR REFRIGERATOR
REINF REINFORCE
REQD REQUIRED
RET RETURN
REV REVISION
RA RETURN AIR
RD ROOF DRAIN
RM ROOM
RO ROUGH OPENING
S
SECT SECTION
SHT SHEET
SIM SIMILAR
SPECS SPECIFICATIONS
STD STANDARD
STL STEEL
STOR STORAGE
SS STAINLESS STEEL
ST STREET
STRUCT STRUCTURAL
SYS SYSTEM
T
TEL TELEPHONE
TEMP TEMPORARY
THRU THROUGH
THK THICK, THICKNESS
T TREAD
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PRECAST
TOS TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
U
UNO UNLESS NOTED OTHERWISE
V
VERT VERTICAL
VEST VESTIBULE
VCT VINYL COMPOSITION TILE
VT VINYL TILE
W
WC WATER CLOSET
W/ WITH
W/O WITHOUT
WD WOOD
X
XPS EXTRUDED POLYSTYRENE
D
DBL DOUBLE
DEMO DEMOLITION
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DIST DISTANCE
DN DOWN
DWG DRAWING
BRICK
MATERIAL DESIGNATIONS
NOTE: ALL MATERIALS SHOWN MAY NOT BE USED IN THIS PROJECT
PATTERN IN PLAN MATERIAL PATTERN IN SECTION MATERIAL
CMU
CONCRETE
EARTH
GRAVEL
SAND
BRICK
CMU
CONCRETE
WOOD
STEEL
KNAUF
INSULATION
ALUMINUM
CEILING TILE
GYPSUM
WALL BOARD
PLYWOOD
BATT
INSULATION
RIGID
INSULATION
SPRAY
INSULATION
WALL CARPET
MIRROR
ELECTRIC
WATER
COOLER
WASTE
RECEPTACLE
HAND DRYER
WITH RECESS KIT
R E
F
LE
C T
IN
G
/4
M A
X T
O
S U
R F
A C
E
2' -1
1/
4"
T O
C O
N T
R O
LS
/4
M A
X
NOTE:
SPOUT OUTLET LOCATED 5" MAX
FROM FRONT EDGE AND 15" MIN
FROM VERTICAL SUPPORT
SOAP
DISPENSER
M
A X
R E
F S
U R
F A
C E
M A
X T
O
W
IT
H O
U T
L A
V
M A
X T
O
M
IN
T O
S P
O U
T O
U T
LE
T
M A
X
M
IN
M A
X
COAT HOOK
SHELF
SANITARY
NAPKIN
RECEPTACLE
PAPER
TOWEL
DISPENSER
TOWEL
DISPENSER
AND WASTE
RECEPTACLE
2' -6
"4' -0
SANITARY
NAPKIN
DISPENSERIDENTIFICATION
PLAQUE
TOILET ROOM SIGNAGE
EXIT PLAQUE
EXIT DISCHARGE DOOR SIGNAGE
9"
CL
9"
CL
TOE AND KNEE
CLEARANCE
8" MIN
1' -0
/4
M
IN
MIN
11"
MIN
17"
M
IN
/4
M A
X
M
IN
M A
X
M
IN
BRACKET
MOUNTED FIRE
EXTINGUISHER
3' -6
1. CONTRACTOR SHALL NOTIFY PROJECT ARCHITECT IN WRITING WHEN WATER DAMAGED DRYWALL, TRIM, ETC. IS FOUND IN PROJECT BEYOND NORMAL PATCH AND REPAIR. CONTRACTOR SHALL REPLACE WATER DAMAGED DRYWALL AREAS, TRIM, ETC. AFTER ARCHITECT EXAMINATION OF CONDITION AND REPLACEMENT APPROVAL. CONTRACTOR SHALL PROVIDE UNIT COST PROPOSAL IN BID FORM BASED ON QUANTITIES INDICATED. CONTRACTOR IS TO NOTIFY ARCHITECT WHEN BLACK MOLD FOUND IN DRYWALL IN WRITING. CONTRACTOR SHALL PROVIDE COST PROPOSAL TO RE-MEDIATE THE MOLD BY A
THIRD PARTY SPECIALIZING IN MOLD REMOVAL.
2. DO NOT SCALE DRAWINGS. IF DIMENSIONS CANNOT BE OBTAINED BASED UPON DRAWING
INFORMATION, CONSULT THE ARCHITECT. ALTERATIONS TO WORK PUT IN PLACE AS A RESULT OF
SCALING DRAWINGS WILL NOT BE REIMBURSED.
3. PROMPTLY REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCE OR OMISSIONS DISCOVERED BY OR MADE KNOWN TO THE CONTRACTOR, INCLUDING DISCREPANCIES BETWEEN FIELD CONDITIONS
AND DRAWINGS, BEFORE PROCEEDING WITH THE WORK.
4. DIMENSIONS ON PLANS ARE TO FACE OF SHEATHING UNLESS NOTED OTHERWISE.
5. PERFORM ALL WORK IN STRICT COMPLIANCE WITH ALL GOVERNING CODES AND STANDARDS.
6. PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2-A OR 2-A/IOBC AS
REQUIRED BY THE FIRE DEPARTMENT DURING ALL PHASES OF CONSTRUCTION.
7. SEPARATE DISSIMILAR METALS TO PREVENT CORROSION AS RECOMMENDED BY THE RESPECTIVE
PRODUCT MANUFACTURER.
8. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING ANY
WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS U.N.O.
9. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE BIDDING DOCUMENTS AND EXAMINE
THE CONSTRUCTION SITE. BIDS SHALL INCLUDE ALL COST REQUIRED TO EXECUTE THE WORK UNDER
EXISTING CONDITIONS. EXTRA PAYMENT WILL NOT BE MADE FOR CONDITIONS WHICH CAN BE
DETERMINED BY STUDYING DRAWINGS AND THE EXISTING CONDITIONS OF THE CONSTRUCTION SITE.
10. GENERAL CONTRACTOR SHALL REMOVE ALL CONSTRUCTION DEBRIS FROM JOB SITE.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SEQUENCING THE INSTALLATION OF NEW AND THE
RELOCATION OF EXISTING PIPES, DUCTWORK, EQUIPMENT, DIFFUSERS, ELECTRICAL, AND SIMILAR
ITEMS REQUIRED TO COMPLETE WORK.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SEQUENCING OF SUBCONTRACTORS WORK AND SHALL ASSUME RESPONSIBILITY FOR ALL COMPLETED AND WORK IN PROGRESS INCLUDING REPAIR OF
DAMAGES TO WORK WHICH OCCUR PRIOR TO ACCEPTANCE BY THE OWNER.
13. PATCH AND REPAIR EXISTING CONSTRUCTION AS REQUIRED BY INSTALLATION OF AND TRANSITION TO
NEW WORK.
14. WORK PERFORMED SHALL BE IN FULL AND COMPLETE COMPLIANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTR. AND
HIS SUBCONTR'S. TO ESTABLISH AND COMPLY WITH SAID CODES AND REGULATIONS.
15. THE CONTRACTOR SHALL EMPLOY ONLY EXPERT TRADESMEN OR CRAFTSMEN WHO ARE THOROUGHLY EXPERIENCED AND CAPABLE OF PRODUCING WORK OF THE QUALITY DESIRED. THE WORK SHALL BE SUPERVISED BY A SUBCONTR. WHO IS KNOWN TO BE EXPERT IN ALL ASPECTS OF THE REQUIRED
WORK.
16. CLEANUP. THE CONTRACTOR SHALL AT ALL TIMES KEEP PUBLIC, OCCUPANT ACCESS, ENTRANCES AND THE WORK FREE FROM ACCUMULATION OF WASTE MATERIALS, RUBBISH AND DIRT CAUSED BY THE WORK. AT THE COMPLETION OF THE WORK REMOVE ALL WASTE AND RUBBISH FROM AND ABOUT THE
PROJECT. AS WELL AS TOOLS, EQUIPMENT AND SURPLUS MATERIALS. CLEAN ALL SURFACES,
WINDOWS AND FLOORS PER SPECIFICATIONS PRIOR TO ACCEPTANCE BY THE OWNER.
17. UNLESS NOTED OTHERWISE ALL WORK IS BY THE CONTRACTOR. CONTRACTOR SHALL PROVIDE ALL MATERIALS, PARTS AND LABOR NECESSARY FOR THE COMPLETION OF SCOPE OF RENOVATION WORK
SHOWN ON THE DRAWINGS AND SPECIFICATIONS IN BUILDING.
18. CONTRACTOR SHALL PROVIDE SEPARATE CONSTRUCTION DUMPSTER AND DO NOT USE COMPLEX
DUMPSTER.
19. THE OWNER WILL NOT BE HELD RESPONSIBLE FOR DAMAGED, LOST OR STOLEN MATERIALS AND
CONTRACTOR'S TOOLS.
20. RENOVATION WORK WILL OCCUR WHILE THE OWNER OR TENANT OF THE OWNER IS OCCUPYING PORTIONS OF THE BUILDING. CONTRACTOR SHALL TAKE CARE OF THE WORK AREA TO PREVENT ANY
DAMAGE OR INJURY TO THE OWNER, ADJACENT TENANT, OR OWNERS EQUIPMENT.
21. CONTRACTOR SHALL PROVIDE ALL MATERIALS AND LABOR FOR PATCHING, REPAIRING, REPLACEMENT, REFINISHING AND PAINTING INTERIOR DRYWALL AS NOTED AND AS REQUIRED.
22. CONTRACTOR SHALL HAVE OWNER AND ARCHITECT WRITTEN APPROVAL FOR PLACEMENT OF SITE STORAGE TRAILER. THE PROPERTY OWNER WILL NOT BE HELD RESPONSIBLE FOR DAMAGED, LOST OR
STOLEN MATERIALS AND CONTRACTORS TOOLS.
23. ALL GENERAL NOTES LISTED ON ALL DRAWINGS APPLY TO ALL DRAWINGS LISTED OR NOT.
24. INSTALL ALL PRODUCTS BY MANUFACTURERS RECOMMENDED INSTALLATION INSTRUCTIONS.
GENERAL NOTES:
THE GENERAL CONTRACTOR AND ALL CONTRACTORS BIDDING ON THIS PROJECT
SHALL VISIT THE SPACE TO FAMILIARIZE THEMSELVES WITH THE ACTUAL JOB
CONDITIONS AND TO CHECK FOR ANY INTERFERENCES BETWEEN THEIR WORK
AND THAT OF OTHER TRADES AND/OR APPARENT EXISTING VIOLATIONS OF LOCAL,
STATE, OR FEDERAL CODES, LAWS, ORDINANCES, AND REGULATIONS BEFORE
ENTERING INTO A CONTRACT WITH EITHER THE GENERAL CONTRACTOR AND/OR
SUBCONTRACTORS
UNFORESEEN CONDITIONS. IF ANY INTERFERENCES OR VIOLATIONS APPEAR AND
DEPARTURE FROM THE DESIGN INTENT OF THE CONTRACT DOCUMENTS IS
REQUIRED, THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND
PROJECT MANAGER IMMEDIATELY, IN WRITING, BEFORE ENTERING INTO A
CONTRACT WITH THE CLIENT. FAILURE TO PROVIDE ARCHITECT AND
CONSTRUCTION MANAGER WITH AFOREMENTIONED NOTIFICATION SHALL RESULT
IN THE SPECIFIC CONTRACTOR BEING HELD RESPONSIBLE TO COMPLETE ALL
WORK REQUIRED TO MEET THE DESIGN INTENT OF THE CONTRACT DOCUMENTS AT
HIS/HER OWN COSTS WITH NO ADDITIONAL EXPENSES (EXTRAS) BEING INCURRED.
NOTE TO ALL CONTRACTORS:
"FURNISH": THE TERM "FURNISH" MEANS TO SUPPLY AND DELIVER TO PROJECT
SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR
OPERATIONS.
"INSTALL": THE TERM "INSTALL" DESCRIBES OPERATIONS AT PROJECT SITE
INCLUDING UNLOADING, TEMPORARY STORING, UNPACKING, ASSEMBLING,
ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSIONS, FINISHING,
CURING, PROTECTING, CLEANED, AND SIMILAR OPERATIONS.
"PROVIDE": THE TERM "PROVIDE" MEANS TO FURNISH AND INSTALL, COMPLETE AND
READY FOR THE INTENDED USE.
STANDARD DEFINITIONS:
M A
N
EO
M A
M A
L U
S N
I N
E P
S I
E R
E U
Q I
S
E C
I P
S M
U C
R I
C
M U
N U
S E
U B
I R
U L
P
SH
EE
T
SI
ZE
x
415 Leonard Street NW, Suite 200 Grand Rapids, MI 49504
(616) 785-5656 www.paradigmae.com
Grand Rapids | Phoenix
ARCHITECTS
PARADIGM DESIGN
ENGINEERS|
INTERIOR DESIGN
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
S T
A T
E O
F M
IC
H
IG
A
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
D M
V A
P R
O
JE
C T
D
TM
B P
R O
JE
C
T
A R
C H
P R
O
JE
C T
R E
V
IS
IO
N
D E
S C
D
A
TE
D e p a rt m e n t o f
M ili ta ry a n d V e te ra n s A ff a ir s
C H
E C
K E
D
D R
A W
N
P .M
S
H E
E T
ID
E
N
TI
FI
C
A
TI
O N
N O
IS
S U
E D
F O
R D
A
TE
TODD OCKASKIS
MI - REGISTRATION # 1301051301
EXP. DATE - 4/30/2027
:3 :1
A M
D M
V A
C A
M P
G R
A Y
L
IN
G B
U
IL
D
IN
G
GENERAL INFORMATION
C A
M P
G R
A Y
L
IN
G
G R
A Y
L
IN
G
M I
A -0
1/
1.
C
A K
0G
R
A ut ho r
C he ck er
SCALE: 1/4" = 1'-0"
ACCESSORY HEIGHTS
B
ID
S
C O
N S
T R
U C
T
IO
N
-2
-2
A-201
A-201
A-201
A-201
C C
D D
B B
A A
1'-6"
3'-4" 5'-8" 18'-0" 18'-6" 18'-0" 18'-0" 18'-0" 3'-0" 3'-4" 6'-8" 18'-0" 12'-0" 18'-0" 12'-0" 18'-0" 12'-0" 18'-0" 7'-8"
'-0
'-0
'-0
11'-6" 3'-4" 5'-8" 18'-0" 18'-6" 18'-0" 76'-0" 3'-4"
1'-6" 2'-0"
6'-0" 6'-0"
6" 1'-2" 17'-10" 21'-0" 15'-0" 31'-0" 32'-0" 1'-0" 27'-0" 32'-0" 30'-0" 30'-0" 1'-2"
11'-0" 7'-0"2'-0"1'-6" 15'-0" 6'-0" 6'-0"
A-301
. .1
A-301
A-301
A-301
3'-4" 4'-0" 4'-8"
COLD
STORAGE104
WORK
BAY
OFFICE
UNISEX
JANITOR
MECHANICAL
STORAGE
STORAGE
2' -8
6'
-4
'-8
3'
-4
9' -4
3'
-4
4' -0
3'
-4
8' -0
3'
-4
1' -4
3'
-4
'-8
"16 '-0
7/ 8"
3' -1
1" 3'
-0
7/
8"
8' -1
/8
7/ 8"
'-5
7/ 8"
'-5
7/ 8"
'-1
99'-8 3/4"
99'-9 3/4"
100'-0"
100'-0"
100'-0"
99'-8 3/4"
1'-6"
100'-0"
B U
IL
D
IN
G
L
IN
E
B U
IL
D
IN
G
L
IN
E
BUILDING LINE
BUILDING LINE
100'-0"
99'-9 3/4"
6' -0
'-8
CRANE RAIL
CRANE RAIL
CRANE RAIL
99'-0"
100'-0"
100'-0"
11'-0" 10'-6"
(4) FLOOR TIE DOWNS
EQUAL TO CHAMP FLOOR
ANCHOR POT 1600 TO
RESIST 10,000 LBS
EXPANDABLE END WALL
PW
WELD TABLE
SHR
LBS
BBS LATHE
WLD
PLZ
MWLD
TWLD
BDP
LDP
5' -7
/8
2'
-6
10"
8" CMU WALL - 3-HR
FIRE BARRIER
6"
'-0
6"
1'-0"
2'-10"
WASH
BAY
'-0
8'-0"
239'-2"
9'-5 5/8"
A-101
A-101
'-0
2'-10"
9'-2" 135'-4" 95'-8" 5'-0"
1' -0
3'
-4
6' -8
3' -6
6'
-6
10'-4" 58'-0"
6' -0
6' -6
9'-0"
2'-10"
5' -0
8" 6'-0"
1'-4"
8'-0"
6' -0
POWER
WASHER
99'-10 1/2"
100'-0"
100'-0" 100'-0"
14'-7"
100'-0"
2'-10"
5' -0
TYP.
2'-0"2'-0"
4' -8
4'
-8
'-0
240'-2"
6"
'-0
6' -8
104H
104G 104F
110A
109A
108A
107A
106A
105A
104A 104B 104C 104D
104E
TYP.
102A
102B
102C
103A
101A 101B 101C
101D
101E
A-303
A-303
TYP.
A -2
-A
A -2
-A A
-2 -A
Z-1-Z
Z-1-Z
Z-1-Z
Z-1-Z
Z-1-Z
A-303
A-303
Z-2-A
Z-2-A
Z-2-A
Z-2-A
E-3-C
C -3
-E
84'-10"
TYP.
Z-4-A
Z-2-A
Z-4-A
TYP
3' -4
8'
-0
3' -4
8'
-0
WALL MOUNTED EYE /
FACE WASH - REFER
TO PLUMBING
BID ALTERNATE #1:
(2) POST LIFT:
CHALLENGER LIFTS E15
OIL
DISPENSER
BID
ALTERNATE #1:
OILSAFE
11W0400
BID
ALTERNATE #1:
COATS
CHD9041
TIRE
MACHINE
SHELF
BID
ALTERNATE #1:
(4) HALLOWELL
F7510-24HG
EDGE OF CONCRETE REFER
TO CIVIL AND STRUCTURAL
EDGE OF CONCRETE REFER
TO CIVIL AND STRUCTURAL
VERIFY WITH
SHOWER
MANUFACTURER
SOAP AND PAPER
TOWEL DISPENSER
AT SINK
SHELF
SHELF SHELF
A
IR
C
O M
P
WALL TYPE KEYNOTES
SHEATHING TYPE
NEW CONSTRUCTION
EXISTING TO REMAIN
THIS NUMBER
CORRESPONDS TO
THE FRAMING TYPE
THIS LETTER
CORRESPONDS TO
THIS SHEATHING
TYPE ON THIS SIDE
OF THE WALL
WALL
THIS LETTER
CORRESPONDS TO
THIS SHEATHING
TYP…