B2604Plans.pdf
PDF 33 MB Posted
- Attached to
- Jackson-Lane Memorial Park Pavilion
- Solicitation number
- B-26-04
- Issued by
- Volusia County, Florida
About this file
This document is a 100% Construction Documents set of architectural and engineering plans for the City of DeLand's Jackson Lane Park Pavilion project located at 720 N. Frankfort Avenue, DeLand, Florida 32724. The project comprises a small outdoor restroom facility classified as Business Group B occupancy with a total building area of 327 gross square feet, featuring separate men's and women's restroom facilities of 130 square feet each, plus a 102-square-foot vestibule. The structure is designed as Type III B non-sprinklered construction with a maximum allowable height of 55 feet and is 14 feet 4 inches in height as designed. The construction documents are complete and include comprehensive architectural, structural, mechanical, electrical, plumbing, fire protection, and civil engineering drawings with detailed specifications, schedules, site plans, and technical details prepared by JL2 Architecture with consultation from TLC Engineering Solutions for mechanical, electrical, and plumbing systems, and BBM Structural for structural engineering.
The documents indicate this is a fully developed design package dated November 14, 2025, issued at 100% Construction Document phase, ready for permitting and bidding purposes. The project appears to be a straightforward municipal restroom facility renovation or new construction at a public park, with standard fire-safety classifications showing 0-hour fire resistance ratings as applicable to the outdoor building type. No pricing, contract award dates, bidding timelines, or funding source information is contained within this architectural plan document; additional procurement documents would be required to identify bid submission deadlines, pricing requirements, and contract terms.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B2604Tabulation.pdf | ||
| B2604ADD3.pdf | ||
| B2604ADD3Attachment.pdf | ||
| B2604ADD2.pdf | ||
| B2604ADD1.pdf | ||
| B2604Plans.pdf | ||
| B2604Specs.pdf | ||
| B2604Specs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A R C H I T E C T U R E
F
E
D
C
B
A
F
E
D
C
B
A sh ee t t itl e:
sheet number:
IF THIS SHEET MEASURES LESS THAN 42" x 30", IT HAS BEEN REDUCED scale:
drawn by:
designed by:
project no.:
issue date:
professional license no.:
name:
pr oj ec t a dd re ss cl ie nt n am e:
pr oj ec t s ta tu s:
pr oj ec t n am e:
AR96099
JOHNNIE LOHRUM, JR.
consultant:
client:
/1
7/
:1 4:
P
M
G000
C O
V E
R S
H E
E T
M.T. & J. F
J. F.
2025-P004
11/14/2025
C ity o f D el a nd
N . F ra nk fo rt
A ve
. A ve
. D e
La nd
, F L
C ity o f D el a nd
Ja ck so n
La ne
P ar k P av ill on
0%
C D
City of Deland - Jackson Lane Park Pavillon PROJECT ADDRESS: 720 N Frankfort Ave. Ave. DeLand, FL 32724
INDEX OF DRAWINGS
100% CONSTRUCTION DOCUMENTS
PLUMBING
P001 PLUMBING SYMBOLS, LEGEND, NOTES AND INDEX
P100 PLUMBING PLAN
MECHANICAL
M001 MECHANICAL SYMBOLS, LEGEND, NOTES AND INDEX
M100 MECHANICAL FLOOR PLAN
ELECTRICAL
E-001 ELECTRICAL SYMBOLS, LEGEND, NOTES AND INDEX
E-002 ELECTRICAL GENERAL NOTES
E-003 ELECTRICAL SPECIFICATIONS
E-101 ELECTRICAL PLANS AND LIGHT FIXTURE SCHEDULE
E-102 ELECTRICAL SITE PLAN
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL ONE-LINE DIAGRAM & DETAILS
CIVIL ENGINEERING
CITY OF DELAND
MECHANICAL, ELECTRICAL, PLUMBING & FIRE
PROTECTION ENGINEERING
TLC ENGINEERING SOLUTIONS
STRUCTURAL ENGINEERING
BBM STRUCTURAL
PROJECT SITE
N
PROJECT SITE
N
LOCATION MAP, NTSVICINITY MAP, NTS
ARCHITECT
JL2 ARCHITECTURE
STRUCTURAL
S001 STRUCTURAL GENERAL NOTES
S002 STRUCTURAL GENERAL NOTES
S101 FOUNDATION PLAN
S102 ROOF FRAMING PLAN
S201 FOUNDATION SECTIONS AND DETAILS
S301 ROOF FRAMING SECTIONS AND DETAILS
S401 SCHEDULES
ARCHITECTURAL
A001 GENERAL INFORMATION, SYMBOLS, & ABBREVIATIONS
A002 GENERAL SPECIFICATIONS
A003 GENERAL SPECIFICATIONS
A004 GENERAL SPECIFICATIONS
A005 GENERAL SPECIFICATIONS
A006 GENERAL SPECIFICATIONS
A007 GENERAL SPECIFICATIONS
A008 GENERAL SPECIFICATIONS
A009 GENERAL SPECIFICATIONS
A010 GENERAL SPECIFICATIONS
A011 GENERAL SPECIFICATIONS
A012 GENERAL SPECIFICATIONS
A013 FLOOR PLAN, EXTERIOR ELEVATIONS
A014 RCP PLAN, BUILDING SECTIONS, INTERIOR ELEVATIONS, DETAILS
A015 DETAILS
NOTE: THE ABOVE RENDERING IS FOR REFERENCE ONLY AND DOES NOT NECESSARILY REPRESENT THE FINAL DESIGN.
INDEX OF GENERAL DRAWINGS
SHEET
NO. SHEET NAME REV. DATE
G000 COVER SHEET
G001 LIFE SAFETY
CIVIL
C1 COVER SHEET
C2 GENERAL NOTES
C3 PAY ITEMS
C4 EXISTING CONDITIONS AND DEMOLITION PLAN
C5 GRADING AND DRAINAGE PLAN
C6 SITE, LANDSCAPE, & UTILITY
C7 DETAILS
C8 UTILITY MARKER BALL LOCATERS
C9 MOT / TTC PLAN
N O
D
E S
C R
IP
T
IO
N
D A
T E
C
D
34"
19'-6"
19'-6"
34"
130 SF
MEN
130 SF
WOMEN
OCCUPANCY CLASSIFICATION (FBC, CHAPTER 3)
FBC, BUILDING, 8TH EDITION, CHAPTER 3 - USE & OCCUPANCY CLASSIFICATION
BUSINESS - PRIMARY FUNCTION: SECTION 303.1.1 (SMALL BUILDING) & 304.1, BUSINESS
GROUP B - OCCUPANCY / : BUSINESS (B)
OCCUPANCY LOAD FACTORS
OCCUPANCY USE / SF PER OCCUPANT FBC (SF) NFPA (SF)
OCCUPANCY CLASSIFICATION
CONSTRUCTION TYPE
B (BUSINESS),(FBC, CHAPTER 3, SECTION 302.1)
TYPE III B CONSTRUCTION (NON-SPRINKLERED)
ALLOWABLE BUILDING HEIGHT*
(FBC, TABLE 504.3)NON-SPRINKLERED
55'
ALLOWABLE STORIES*
(FBC TABLE 504.4)
ALLOWABLE BUILDING AREA*
(FBC, TABLE 506.2)
19,000 SF
BUILDING SPECIFIC INFORMATION (OUTDOOR RESTROOM)
FBC ALLOWABLE BUILDING REQUIREMENTS
AS REQUIRED AS DESIGNED
14'-4"
327 GSF
PRIMARY STRUCTURAL FRAME
BEARING WALLS, EXTERIOR 2 HOURS
FIRE RESISTANCE BY CONSTRUCTION TYPE (FBC, TABLE 601)
0 HOURS (NOT APPLICABLE)
BEARING WALLS, INTERIOR 0 HOURS (NOT APPLICABLE)
NONBEARING WALLS, EXTERIOR 0 HOURS (NOT APPLICABLE)
NONBEARING WALLS, EXTERIOR 0 HOURS (PER TABLE 705.5, 10 < X < 30)
FLOOR CONSTRUCTION 0 HOURS (NOT APPLICABLE)
ROOF CONSTRUCTION 0 HOURS
CORRIDORS 0 HOURS (NOT APPLICABLE)
EXIT STAIRS 0 HOURS (NOT APPLICABLE)
FLOOR OPENINGS / SHAFTS 0 HOURS (NOT APPLICABLE)
CONSTRUCTION TYPE
1-HOUR FIRE BARRIER 3/4 HOUR
OPENING PROTECTIVES IN FIRE RESISTANT CONSTRUCTION
FIRE RESISTANCE RATING
2-HOUR FIRE BARRIER 1-1/2 HOUR
1-HOUR EXIT ENCLOSURE 1 HOUR
SMOKE PARTITION 1/3 HOUR
ROOM & FINISH TYPE
EXITS CLASS A
INTERIOR FINISHES (FBC, TABLE 803.11)
FIRE RESISTANCE RATING
EXIT ACCESS CORRIDORS
OTHER THAN EXITS
CLASS B
CLASS C
INTERIOR FLOOR FINISHES PER FBC, SECTION 804
GENERAL ASSEMBLY AREAS (>300) N/A
N/AGENERAL ASSEMBLY AREAS (<300)
OCCUPANCY LOAD
BUSINESS (150 GSF) 4 OCCUPANTS
TOTAL OCCUPANCY = 2 OCCUPANTS
EGRESS CAPACITY
LEVEL EXIT WIDTH REQUIRED
4 PERSON x 0.2" = 0.8 INCHESFIRST FLOOR
EXIT WIDTH AS DESIGNED
34 INCHES
EGRESS COMPONENTS
MIN. NUMBER OF EXITS 2 (PER FBC, TABLE 1006.3.2)
MAX. TRAVEL DISTANCE 200 FEET,WITHOUT SPRINKLER (PER FBC, TABLE 1017.2)
MAX. COMMON PATH OF TRAVEL 30 FEET
MAX. DEAD END CORRIDOR NOT APPLICABLE
MIN. CORRIDOR WIDTH NOT APPLICABLE
MIN. STAIR WIDTH NOT APPLICABLE
MIN. DOOR WIDTH 0.2 INCHES PER PERSON (PER FBC, TABLE 1005.1)
BUSINESS (B) 150 GSF 150 GSF
NOT APPLICABLE
PROJECT SUMMARY
THE PROJECT DESIGNED IS A NEW 327 SF PAVILION FOR THE CITY OF DELAND AT JACKSON
LANE MEMORIAL PARK. THE PAVILION WILL INCLUDE RESTROOMS AS WELL AS SPACE FOR
OUTDOOR SEATING. THE PAVILION WILL CONSIST OF WOOD FRAME CONSTRUCTION FOR ITS
POST AND ROOF AND WILL UTILIZE CMU FOR THE RESTROOM CONTRUCTION.
APPLICABLE CODES
BUILDING:
FIRE / LIFE SAFETY:
FLORIDA BUILDING CODE, BUILDING - 8TH EDITION
FLORIDA FIRE PREVENTION CODE, 8TH EDITION
NFPA 1 FIRE CODE, 2021 EDITION
NFPA 101 LIFE SAFETY CODE, 2021 EDITION
PLUMBING: FLORIDA BUILDING CODE, PLUMBING, 8TH EDITION
FLORIDA BUILDING CODE, FUEL GAS, 8TH EDITION
MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL, 8TH EDITION
ELECTRICAL: FLORIDA BUILDING CODE, CHAPTER 27, 8TH EDITION
NFPA 70, NATIONAL ELECTRICAL CODE, 2020 EDITION
NFPA 72, NATIONAL FIRE ALARM CODE, 2019 EDITION
ACCESSIBILITY: FLORIDA BUILDING CODE, ACCESSIBILITY, 8TH EDITION
AGENCIES HAVING JURISDICTION
BUILDING: CITY OF DELAND, FL (AHJ)
THE APPLICABLE CODES AS REQUIRED BY THE CODE OF ORDINANCE CITY OF DELAND,
FLORIDA. PERTINENT SECTION ARE, BUT NOT LIMITED TO,
CHAPTER 6 - BUILDINGS AND BUILDING REGULATIONS.
CHAPTER 7 - BUILDING AND HOUSING CODES
CHAPTER 9 - CONSTRUCTION INDUSTRY LICENSING
CHAPTER 10 - ELECTRICITY
CHAPTER 10B - EMERGENCY MANAGEMENT
CHAPTER 12 - FIRE PREVENTION
CHAPTER 15 - SOLID WASTE
CHAPTER 16 - HEALTH AND SANITATION
CHAPTER 20 - NOISE
CHAPTER 25 - PLUMBING
CHAPTER 26 - STREET AND SIDEWALKS
CHAPTER 28 - TRAFFIC AND PARKING
CHAPTER 30 - UTILITIES
CHAPTER 33 - LAND DEVELOPMENT
FIRE / LIFE SAFETY: CITY OF DELAND FIRE CHIEF AND DEPUTY CHIEF OF FIRE
OPERATIONS
TEST PROTOCOLS: FLORIDA BUILDING CODE, TEST PROTOCOLS FOR HIGH-VELOCITY
HURRICANE ZONE, 8TH EDITION
ENERGY: FLORIDA BUILDING CODE, ENERGY CONSERVATION, 8TH EDITION
GENERAL INFORMATION
SITE: DELAND, FL (VOLUSIA COUNTY)
NOTES:
1. PARTITIONS NOT EXCEEDING 60 INCHES AND IN LOCATIONS OTHER THAN EXITS
LOW HEIGHT PARTITIONS CLASS C
ACTUAL (327 GSF) / BUSINESS (150 GSF) =
TRAVEL DISTANCE TO EXIT, COMMON PATH
LIFE SAFETY SYMBOLS
FIRE EXTINGUISHER, CABINET
1 HOUR FIRE BARRIER
NON-RATED PARTITION
FEC
FIRE EXTINGUISHER, WALL MOUNTEDFE
WIDTH OF EGRESS UNITS (IN)36"
WALL SPEAKER / STROBE
FIRE STROBE ONLY
WALL MOUNTED EXIT LIGHT
CEILING MOUNTED EXIT LIGHT
CEILING MOUNTED SMOKE DETECTOR
MANUAL PULL STATIONP
SPEAKER
CEILING SPEAKER STROBE
1000 SF
100 SF 10
BUSINESS OCCUPANCY GROUP
TOTAL ROOM AREA
ALLOWABLE TOTAL
OCCUPANCY (MAX)
MAX FLOOR AREA
ALLOANCE PER
OCCUPANT
NOTE: NOT ALL ITEMS IN THIS LEGEND MAY BE USED.
2 HOUR FIRE BARRIER
SECURE SPACE PERIMETER
A R C H I T E C T U R E
F
E
D
C
B
A
F
E
D
C
B
A sh ee t t itl e:
sheet number:
IF THIS SHEET MEASURES LESS THAN 42" x 30", IT HAS BEEN REDUCED scale:
drawn by:
designed by:
project no.:
issue date:
professional license no.:
name:
pr oj ec t a dd re ss cl ie nt n am e:
pr oj ec t s ta tu s:
pr oj ec t n am e:
consultant:
client:
/1
4/
:1 9:
P
M
As indicated
G001
LI
FE
S A
FE
TY
M.T. & J. F
J.F.
2025-P004
11/14/2025
C ity o f D el a nd
N . F ra nk fo rt
A ve
. A ve
. D e
La nd
, F L
C ity o f D el a nd
Ja ck so n
La ne
P ar k P av ill on
0%
C D
1/4" = 1'-0"
FIRST FLOOR - LIFE SAFETY PLAN
N O
D
E S
C R
IP
T
IO
N
D A
DESIGN CRITERIA
ALL WORK SHALL CONFORM TO AT LEAST THE MINIMUM STANDARDS OF
THE FLORIDA BUILDING CODE (FBC), EIGHTH EDITION (2023).
D1
DESIGN LOAD VALUES ARE INDICATED ON THE APPROPRIATE SHEETS
AS FOLLOWS:
FOUNDATION DESIGN - SEE FOUNDATION NOTE F2 ON THIS SHEET
ROOF FRAMING DESIGN - SHEET S102.
WIND DESIGN - SHEET S401.
RAIN DESIGN:
15 MINUTE RAINFALL INTENSITY: 7.46 IN/H.
60 MINUTE RAINFALL INTENSITY: 4.12 IN/H.
D2
TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE
STRUCTURAL PLANS AND SPECIFICATIONS HAVE BEEN
DESIGNED IN ACCORDANCE WITH THE BUILDING CODE.
D3
EVERY REASONABLE EFFORT HAS BEEN MADE TO
ENSURE COORDINATION BETWEEN THESE DRAWINGS AND
THE BOUND STRUCTURAL SPECIFICATIONS. SHOULD
THERE BE ANY DISCREPANCIES, THE CONTRACTOR SHALL
THEN REQUEST A CLARIFICATION IN WRITING.
D4
GENERAL
THE GENERAL CONTRACTOR SHALL REVIEW AND DETERMINE THAT
DIMENSIONS ARE COORDINATED BETWEEN ARCHITECTURAL AND
STRUCTURAL DRAWINGS PRIOR TO FABRICATION OR START OF
CONSTRUCTION.
G1
THE GENERAL CONTRACTOR SHALL PROVIDE ALL MEASURES
NECESSARY TO PROTECT THE STRUCTURE, THE WORK PERSONNEL AND
OTHER PEOPLE DURING CONSTRUCTION. HE SHALL SUPERVISE AND
DIRECT THE WORK AND BE RESPONSIBLE FOR ALL CONSTRUCTION.
G2
NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED OR OTHERWISE
REDUCED IN STRENGTH.
G3
THE GENERAL CONTRACTOR SHALL COORDINATE ARCHITECTURAL
MECHANICAL AND ELECTRICAL DRAWINGS FOR ANCHORED,
EMBEDDED AND SUPPORTED ITEMS WHICH AFFECT THE STRUCTURAL
DRAWINGS AND NOTIFY THE ARCHITECT/ENGINEER OF ANY
DISCREPANCIES.
G4
ALL SHOP DRAWING SUBMITTALS SHALL BE SUBMITTED VIA
ELECTRONIC MEDIA (i.e. PDF OR DWF FORMAT). HARD COPY
SUBMITTALS WILL NOT BE ACCEPTED.
SUBMITTALS SHALL NOT BE SECURED IN ANY FORMAT
THAT WILL PREVENT COMMENTS FROM BEING ADDED.
SUBMITTALS THAT ARE REQUIRED TO BE SIGNED AND
SEALED SHALL BE SUBMITTED WITH A CERTIFIED DIGITAL
SIGNATURE CONSISTENT WITH REQUIREMENTS OF STATE
LAW WHERE THE PROJECT IS LOCATED. INVALID OR
BLANK SIGNATURE FIELDS WILL NOT BE ACCEPTED.
SUBMITTALS THAT ARE MARKED PRELIMINARY OR ARE
OTHERWISE INCOMPLETE WILL BE RETURNED REJECTED
AND OR NOT REVIEWED. SUBMITTALS SHALL BE IN FINAL
OR COMPLETED STATE PRIOR TO SUBMISSION TO BBM.
G5
1.
2.
ANY SUBMITTALS RECEIVED BY ARCH/ENG THAT HAVE NOT BEEN
CHECKED BY THE GC AND HIS SUB-CONTRACTOR SHALL BE RETURNED
WITHOUT REVIEW.
G6
ALL SECTIONS AND DETAILS SHALL BE CONSTRUED TO BE TYPICAL OR
SIMILAR UNLESS ANOTHER SECTION OR DETAIL IS NOTED.
G7
ANY CONFLICTS NOTICED, OR OBSERVED, BETWEEN THE WRITTEN
SPECIFICATIONS AND THE CONSTRUCTION DOCUMENTS DURING PROJECT
BIDDING OR PROJECT CONSTRUCTION SHALL BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE STRUCTURAL ENGINEER-OF-RECORD. IF
SUCH DISCREPANCY IS NOT NOTICED OR BROUGHT TO THE ATTENTION
OF THE STRUCTURAL ENGINEER-OF-RECORD FOR WRITTEN
CLARIFICATION, THE CONTRACTOR/SUB-CONTRACTOR SHALL PROVIDE,
AT PROJECT BID OR DURING PROJECT CONSTRUCTION, THE MORE
STRINGENT AND/OR MORE COSTLY OF THE TWO ITEMS IN THE BID
AND/OR FINAL INSTALLATION.
G8
"BBM STRUCTURAL ENGINEERS" ASSUMES NO RISK OR LIABILITY FOR
THE SITE SAFETY OR WELL-BEING OF ANY CONTRACTOR, SUB-
CONTRACTOR NOR THEIR EMPLOYEES DURING THE CONSTRUCTION OF
THE PROJECT CONTAINED IN THESE DOCUMENTS.
G9
GENERAL CONTRACTOR/CONSTRUCTION MANAGER SHALL SUPPLY ALL
SUB-CONTRACTORS WITH THE STRUCTURAL GENERAL NOTE SHEETS AS
WELL AS THE STRUCTURAL DRAWINGS.
G10
G11 THE CONTRACTOR'S MEANS AND METHODS SHALL FULLY CONFORM TO
THE REQUIREMENTS OF SEI/ASCE 37 (DESIGN LOADS ON STRUCTURES
DURING CONSTRUCTION) UNTIL ALL OF THE STRUCTURAL ELEMENTS ARE
IN PLACE AND HAVE RECEIVED THE INSPECTOR'S APPROVAL.
REFER TO ARCHITECTURAL DRAWINGS FOR ROOF COVERINGS. ROOFS
SHALL BE INSPECTED BY A LICENSED ENGINEER/ARCHITECT AND A
REPRESENTATIVE OF THE ROOFING MANUFACTURER AND REPORTS
SHALL BE SUBMITTED TO THE OWNER AND ARCHITECT.
G12
3.
SPECIALTY ENGINEERING REQUIREMENTS
SE2
SE1 GUARDRAILS, HANDRAILS, POSTS AND SUPPORT CONNECTIONS SHALL
BE DESIGNED BY THE FABRICATOR'S SPECIALTY ENGINEER. SHOP
DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED FOR REVIEW
AND MUST BE SIGNED, DATED AND SEALED BY A ENGINEER
REGISTERED IN THE SAME STATE AS THE PROJECT LOCATION. DUE
CONSIDERATION SHALL BE GIVEN TO EXPANSION & CONTRACTION BY
PROVIDING SLIP JOINTS AS REQUIRED. DESIGN LOADING(S) SHALL
CONFORM TO ALL REQUIREMENTS OF THE BUILDING CODE (SEE
DESIGN CRITERIA FOR THE APPLICABLE BUILDING CODE).
FLAGPOLES AND SITE LIGHTING POLES SHALL BE DESIGNED BY THE
POLE VENDOR'S SPECIALTY ENGINEER AND SHALL INCLUDE POLES,
FOUNDATIONS AND CONNECTIONS. SHOP DRAWINGS AND CALCULATIONS
SHALL BE SUBMITTED FOR REVIEW AND MUST BE SIGNED, DATED AND
SEALED BY A STRUCTURAL ENGINEER REGISTERED IN THE SAME STATE
AS THE PROJECT LOCATION. MINIMUM DESIGN LOADS SHALL CONFORM
TO NAAMM FP1001-17 "SPECIFICATIONS FOR DESIGN LOADS OF METAL
FLAGPOLES".
CONTRACTOR SHALL SUBMIT FOR ENGINEER'S APPROVAL A SHORING/RE-
SHORING PLAN WITH SECTIONS AND CALCULATIONS, SIGNED, DATED AND
SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE SAME STATE AS
PROJECT LOCATION.
SE3
TRUSSES AND THEIR CONNECTIONS SHALL BE DESIGNED BY A SPECIALTY
ENGINEER. SHOP DWGS AND CALCULATIONS SHALL BE SUBMITTED FOR REVIEW
AND MUST BE SIGNED, DATED AND SEALED BY AN ENGINEER REGISTERED IN
THE SAME STATE AS THE PROJECT LOCATION.
SE4
REFER TO STRUCTURAL STEEL NOTES FOR CONNECTION ENGINEERING.SE5
SLAB ON GRADE
SOG1
MAXIMUM SPACING OF CONTROL JOINTS (i.e. SAWCUT JOINT OR
CONSTRUCTION JOINT) SHALL BE AS SET IN THE TABLE BELOW, OR AS
NOTED ON PLANS. THE MORE STRINGENT SHALL APPLY. PATTERNS SHALL
BE APPROXIMATELY SQUARE WITH A RATIO OF LONG SIDE TO SHORT SIDE
NOT EXCEEDING 1.5 TO 1. SEE SLAB-ON-GRADE DETAILS FOR ADDITIONAL
INFORMATION.
SOG2
(IN)
SLAB
THICKNESS
3/4" OR LARGER
AGGREGATE SPACING
(FT)
7 AND
GREATER
MIX DESIGNS CONTAINING
AGGREGATE LESS THAN 3/4"
ARE NOT ACCEPTABLE.
GENERAL CONTRACTOR SHALL COORDINATE EXACT LOCATION OF SJ'S AND
CJ'S WITH ARCHITECTURAL FLOOR FINISHES TO ENSURE SLAB JOINTS DO
NOT READ THROUGH.
SOG3
SLAB THICKNESS SHALL BE INCREASED AS REQUIRED TO PROVIDE
ADEQUATE SUPPORT FOR CRANE LOADS WITHOUT CRACKING SLAB.
SOG4
UNLESS NOTED OTHERWISE IN THE GEOTECHNICAL REPORT, COMPACT
INTERIOR FILL TO 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY
(ASTM D1557). SOIL COMPACTION SHALL BE FIELD-CONTROLLED BY A
REPRESENTATIVE TECHNICIAN OF A QUALIFIED LABORATORY. EACH LAYER
OF FILL SHALL NOT EXCEED 12" THICK AND SHALL BE COMPACTED PRIOR
TO PLACEMENT OF NEXT LAYER.
FOUNDATIONS
A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY-
STANDARD SOIL DENSITY TESTS TO ENSURE CONFORMANCE WITH GEOTECHNICAL
SOILS REPORT. SUBMIT REPORTS TO ARCHITECT AND ENGINEER.
F3
CONTRACTOR, IN CONJUNCTION WITH GEOTECHNICAL FIELD REPRESENTATIVE,
SHALL DETERMINE IF ANY UNSUITABLE CONDITIONS ARE DISCOVERED DURING
EXCAVATION WHICH WOULD PREVENT ATTAINMENT OF THE DESIGN SOIL
PRESSURE RECOMMENDED BY THE SOILS REPORT.
F4
FOOTINGS SHALL BE CAST TO THE SCHEDULED SIZE AND SHALL NOT BE
OVERSIZED BY MORE THAN 6" ON ANY SIDE FOR FOOTING WIDTH OF AT
LEAST 6'-0". FOR FOOTINGS LESS THAN 6'-0" IN WIDTH THE MAXIMUM
OVERSIZING SHALL BE 3".
F5
CONTRACTOR SHALL BE PREPARED FOR AND SHALL INCLUDE COST OF FORMING
FOUNDATIONS SHOULD THE EARTH NOT PROVIDE ADEQUATE BANK STABILITY.
F6
SUBSURFACE INVESTIGATION HAS NOT BEEN PERFORMED AND GEOTECHNICAL
ENGINEERING REPORT WAS NOT AVAILABLE FOR FOUNDATION DESIGN. PRIOR
TO CONSTRUCTION, THE OWNER SHALL RETAIN THE SERVICES OF A QUALIFIED
GEOTECHNICAL ENGINEER TO PERFORM SOIL TEST BORINGS, PROVIDE
RECOMMENDATIONS FOR FOUNDATION DESIGN (INCLUDING NET ALLOWABLE
SOIL BEARING PRESSURE), PROVIDE EARTHWORK COMPACTION CRITERIA, AND
PERFORM SOIL TESTING DURING CONSTRUCTION. THE CONTRACTOR IS
RESPONSIBLE FOR PERFORMING ALL EARTHWORK OPERATIONS IN STRICT
ACCORDANCE WITH THIS REPORT. IF THE FOUNDATION RECOMMENDATIONS AND
NET ALLOWABLE SOIL BEARING CAPACITY DIFFER FROM THE ASSUMED VALUE,
THEN MODIFICATIONS TO THE DRAWINGS WILL BE REQUIRED. SHOULD THIS
OCCUR, THE CONTRACTOR SHALL STOP CONSTRUCTION AND NOTIFY
ARCHITECT/ ENGINEER IMMEDIATELY.
F1
FOUNDATION DESIGN IS BASED ON AN ASSUMED NET ALLOWABLE SOIL
BEARING PRESSURE OF 2,000 PSF. COMPACTION UNDER ALL
FOUNDATIONS SHALL ALSO BE AS STATED IN NOTE SOG1.
F2
POST-INSTALLED ANCHORS
PIA1
PIA3
POWDER-ACTUATED FASTENERS (PAF) SHALL BE BY SIMPSON STRONG-TIE
(ICC-ES ESR-2138), HILTI (ICC-ES ESR-1663 AND ESR-2269), DEWALT "POWER
DRIVEN FASTENERS" (ICC-ES ESR-2024) OR ENGINEER-APPROVED EQUAL.
REFER TO LIGHT-GAGE FRAMING NOTES (IF APPLICABLE) FOR
ADDITIONAL INFORMATION.
ANCHORAGE TO SOLID-GROUTED CONCRETE MASONRY
POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE
CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM
THE STRUCTURAL ENGINEER-OF-RECORD (SEOR) PRIOR TO INSTALLING POST-
INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACE
ANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID
CONFLICTS WITH EXISTING REBAR. HOLES SHALL BE DRILLED AND CLEANED AND
PRODUCT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED
INSTALLATION INSTRUCTIONS (MPII). SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER
THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE
STRUCTURAL ENGINEER-OF-RECORD ALONG WITH CALCULATIONS THAT ARE
PREPARED & SEALED BY A REGISTERED PROFESSIONAL ENGINEER IN THE SAME
STATE AS PROJECT LOCATION. THE CALCULATIONS SHALL DEMONSTRATE THAT THE
SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT OR BETTER
PERFORMANCE VALUES OF THE SPECIFIED PRODUCT USING THE APPROPRIATE
DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE BUILDING CODE.
CONCRETE ANCHORS:
MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE
SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH
ACI 355.2 AND ICC-ES AC193. PRE-APPROVED MECHANICAL ANCHORS
INCLUDE:
HILTI KWIK BOLT-TZ2 EXPANSION ANCHOR SAFE SET SYSTEM WITH AT
MODULE FOR APPLICABLE SIZES (ICC-ES ESR-4266)
HILTI KWIK BOLT 1 EXPANSION ANCHOR SAFE SET SYSTEM WITH
HOLLOW DRILL BIT AND VACUUM AND AT MODULE FOR APPLICABLE
SIZES PER IAPMO UES ER-678
SIMPSON STRONG-TIE "STRONG-BOLT 2" (ICC-ES ESR-3037)
SIMPSON STRONG-TIE "TITEN-HD" (ICC-ES ESR-2713)
DEWALT "POWER-STUD+ SD1" (ICC-ES ESR-2818)
DEWALT "POWER-STUD SD2, SD4 (304SS) AND SD6 (316SS)"
(ICC-ES ESR-2502)
DEWALT "SCREW-BOLT+" (ICC-ES ESR-3889)
DEWALT "SNAKE+" (ICC-ES ESR-2272)
A.
B.
PIA4 MASONRY ANCHORS:
A.
MECHANICAL AND CONCRETE SCREW ANCHORS FOR USE IN SOLID-
GROUTED CONCRETE MASONRY SHALL HAVE BEEN TESTED AND
QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC01 OR AC106,
RESPECTIVELY. PRE-APPROVED MECHANICAL AND CONCRETE
SCREW ANCHORS INCLUDE:
HILTI KWIK BOLT-TZ2 EXPANSION ANCHOR PER ICC-ES ESR-4561
SIMPSON STRONG-TIE "STRONG-BOLT 2" (IAPMO UES ER-240)
DEWALT "POWER-STUD+ SD1" (ICC-ES ESR-2966)
DEWALT "SCREW-BOLT+" (ICC-ES ESR-4042)
ADHESIVE ANCHORS FOR USE IN SOLID-GROUTED CONCRETE
MASONRY SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE
IN ACCORDANCE WITH ICC-ES AC58. PRE-APPROVED ADHESIVE
ANCHORS INCLUDE:
HILTI HIT-HY 270 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL
BIT AND VACUUM PER ICC-ES ESR-4143
SIMPSON STRONG-TIE "SET-XP" (IAPMO UES ER-265)
SIMPSON STRONG-TIE "AT-XP" (IAPMO UES ER-281)
DEWALT AC100+ GOLD (ICC-ES ISR-3200)
B. ANCHORAGE TO HOLLOW CONCRETE MASONRY / UNREINFORCED
CLAY BRICK MASONRY
SCREW ANCHORS FOR USE IN HOLLOW CONCRETE MASONRY
SHALL HAVE BEEN TESTED AND QUALIFIED IN ACCORDANCE
WITH ICC-ES AC106. PRE-APPROVED SCREW ANCHORS
INCLUDE:
SIMPSON STRONG-TIE "TITEN-HD" (ICC-ES ESR-1056)
ADHESIVE ANCHORS WITH SCREEN TUBES FOR USE IN HOLLOW
CONCRETE MASONRY / UNREINFORCED CLAY BRICK MASONRY
SHALL BE TESTED AND QUALIFIED IN ACCORDANCE WITH ICC-ES
AC58 OR AC60, AS APPROPRIATE. THE APPROPRIATE SCREEN
TUBE SHALL BE USED AS RECOMMENDED BY THE ADHESIVE
MANUFACTURER. PRE-APPROVED ADHESIVE ANCHORS WITH
SCREEN TUBES INCLUDE:
HILTI HY 270 ADHESIVE ANCHOR (ICC-ES ESR-4143)
SIMPSON STRONG-TIE "SET-XP" (IAPMO UES ER-265)
SIMPSON STRONG-TIE "ACRYLIC-TIE" (ICC-ES ER-5791)
DEWALT AC100+ GOLD (ICC-ES ISR-3200)-HOLLOW CONCRETE MASONRY
PIA5
PIA7
1.
3.
4.
6.
7.
2.
1.
2.
GAS-ACTUATED FASTENERS (GAF) SHALL BE BY SIMPSON STRONG-TIE
(ICC-ES ESR-2811), HILTI (ICC-ES ESR-1752), DEWALT "TRAK-IT C5
FASTENERS" (ICC-ES ESR-3275) OR ENGINEER-APPROVED EQUAL.
PIA6
9.
10.
1.
2.
3.
PIA2 THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER'S REPRESENTATIVE
TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING
PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD MUST RECEIVE
DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S PERSONNEL WHO
INSTALL ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING
ANCHORS. ADDITIONALLY, INSTALLATION OF ADHESIVE ANCHORS IN HORIZONTAL TO
VERTICALLY OVERHEAD ORIENTATION SHALL BE DONE BY CERTIFIED ADHESIVE
ANCHOR INSTALLER (AAI) AS CERTIFIED THROUGH ACI AND IN ACCORDANCE WITH
ACI 318-19 (SECTION 17.2.3). PROOF OF CURRENT CERTIFICATION SHALL BE SUBMITTED
PRIOR TO COMMENCEMENT OF INSTALLATION.
4.
HILTI
HILTI HIT-HY 200 V3 SAFE SET SYSTEM WITH THE HILTI HIT-Z ROD
PER ICC ESR-4868.
HILTI HIT-HY 200 V3 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT
(TE-CD OR TE-YD) AND VACUUM WITH HAS-E THREADED ROD PER
ICC ESR-4868.
HILTI HY 200 V3 ADHESIVE ANCHOR USING TRADITIONAL CLEANING
METHOD, 2 BLOWS OF COMPRESSED AIR (90 PSI MINIMUM, OIL FREE
COMPRESSOR), 2 BRUSHES WITH SAME SIZE AS HOLE WIRE BRUSH
AND 2 MORE BLOWS, (2x2x2 CLEANING METHOD) PER ICC ESR-4868.
a.
b.
c.
HILTI HIT-RE 500-V3 EPOXY ADHESIVE ANCHORING SYSTEM WITH
HAS-E THREADED ROD PER ICC ESR-3814 FOR SLOW CURE
APPLICATIONS.
d.
SIMPSON STRONG-TIE "ET-3G" (ICC-ES ESR-5334)5.
SIMPSON STRONG-TIE "AT-XP" (IAPMO UES ER-263)
1. DEWALT
2. DEWALT AC200+ GOLD (ICC-ES ESR-4027)
c.
f.
SIMPSON STRONG-TIE "TITEN-HD" (ICC-ES ESR-1056)g.
a.
b.
b.
d.
e.
a.
a.
c.
d.
e.
a.
ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL
BE INSPECTED AS FOLLOWS: AT THE ONSET OF EACH APPLICATION, A
MANUFACTURER'S REPRESENTATIVE MUST BE PRESENT TO WITNESS AT LEAST
FIVE COMPLETE INSTALLATIONS. INSTALLERS MUST BE TRAINED BY THE
MANUFACTURER AND MANUFACTURER SHALL SUBMIT DOCUMENTATION TO THE
CONTRACTOR INDICATING TRAINING HAS TAKEN PLACE. TRAINED INSTALLERS
SHALL PROVIDE WRITTEN DOCUMENTATION TO THE CONTRACTOR THAT ALL
ANCHORS HAVE BEEN INSTALLED PER THE MPII. CONTRACTOR SHALL SUBMIT
THIS DOCUMENTATION TO THE SEOR. ADHESIVE ANCHORS SHALL BE INSTALLED
IN CONCRETE HAVING MINIMUM AGE OF 21 DAYS. HOLES SHALL BE DRY AT THE
TIME OF INSTALLATION. ADHESIVES SHALL HAVE MAX IN-SERVICE SHORT-TERM
TEMPERATURE OF 150˚F, AND MAX IN-SERVICE LONG-TERM TEMPERATURE OF
110˚F. PRIOR TO INSTALLATION OF ADHESIVE ANCHORS IN HORIZONTAL OR
UPWARDLY INCLINED ORIENTATIONS RESISTING SUSTAINED TENSION LOADS,
INSTALLERS ARE REQUIRED TO BE CERTIFIED IN ACCORDANCE WITH THE ACI /
CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM AND MUST BE
CONTINUOUSLY INSPECTED. ANCHORS SHALL ALSO HAVE BEEN TESTED AND
QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC308. PRE-APPROVED
ADHESIVE ANCHORS INCLUDE THE FOLLOWING PRODUCTS:
6.
SIMPSON STRONG-TIE "ET-HP" (ICC-ES ESR-3372)
SIMPSON STRONG-TIE "ET-HP" (IAPMO UES ER-241)f.
DEWALT "MINI-UNDERCUT+" (ICC-ES ESR-3912)5.
DEWALT AC100+ GOLD (ICC-ES ISR-4105)-CLAY BRICK MASONRYb.
SIMPSON STRONG-TIE "STAINLESS STEEL TITEN HD" (IAPMO UES ER-493)
(316 OR 304 STAINLESS STEEL)
11.
7.
SIMPSON STRONG-TIE "SET-3G" (ICC-ES ESR-4057)
CORDLESS DIRECT FASTENERS (CDF) SHALL BE BY DEWALT (ICC-ES ESR-4076)
OR ENGINEER-APPROVED EQUAL.
PIA8
"PURE 220+" WITH DUSTX+ HOLLOW DRILL BIT SYSTEM OR USING
TRADITIONAL BLOW OUT METHOD PER ICC-ES ESR-5144.
AC200+ WITH DUSTX+ HOLLOW DRILL BIT SYSTEM OR USING
TRADITIONAL BLOW OUT METHOD PER ICC-ES ESR-4027.
a.
b.
HILTI KWIK-X DUAL ACTION ANCHOR SAFESET SYSTEM WITH KHC
CAPSULE ADHESIVE AND KWIK-HUS EZ PER ICC ESR-5065.
e.
HILTI KWIK BOLT-1 EXPANSION ANCHOR PER IAPMO UES ER-677d.
HILTI KH-EZ, KH-EZ CRC, KH-EZ SS316, KH-EZ C, AND KH-EZ P
SCREW ANCHORS PER ICC-ES ESR-3056
e.
HILTI HIT-HY 200 V3 SAFE SET SYSTEM WITH HILTI HOLLOW
DRILL BIT AND VACUUM PER ICC ESR-4878
c.
HILTI KWIK HUS-EZ (KH-EZ), KH-EZ CRC, KH-EZ SS316, KH-EZ C,
KH-EZ E, KH-EZ I, AND KH-EZ P SCREW ANCHOR SAFE SET SYSTEM
WITH HOLLOW DRILL BIT AND VACUUM PER ICC-ES ESR-3027
8.
POST-INSTALLED ANCHORS (cont).
FLORIDA PRODUCT APPROVAL / NOTICE OF ACCEPTANCE
THE STRUCTURAL ROOF DECK(S) FOR THIS PROJECT HAVE BEEN
DESIGNED TO BE COMPLIANT WITH THE CODES AND PRESSURES LISTED
HEREIN. ANY PRODUCTS INSTALLED OVER THE STRUCTURAL DECK(S)
SHALL HAVE BEEN TESTED AS AN ASSEMBLY, INCLUSIVE OF THE
STRUCTURAL DECK, AND SHALL BE SUBMITTED FOR APPROVAL WITH
THE FPA/NOA CLEARLY IDENTIFIED. FAILURE TO PROVIDE THIS
INFORMATION SHALL BE CAUSE FOR REJECTION BY THE ARCHITECT
AND BBM STRUCTURAL ENGINEERS, INC. ALL WARRANTIES MUST BE
PART OF THE ROOFING SUBMITTAL. ANY WARRANTY CONTAINING
LANGUAGE WHICH "EXCLUDES GALE AND/OR HURRICANE FORCE WIND
DAMAGE", OR "EXCLUDES DAMAGE FROM GALE AND/OR HURRICANE
FORCE WINDS", OR ANY OTHER SIMILAR VERBIAGE, SHALL BE
REJECTED AND THE ENTIRE PRODUCT ASSEMBLY SHALL NOT BE
PERMITTED FOR USAGE ON THE PROJECT.
FPA1
RATIONAL ANALYSIS OF THE ROOF SYSTEM SHALL NOT BE
PERMITTED WITHOUT THE WRITTEN CONSENT OF THE OWNER,
ARCHITECT AND ENGINEER, AND THEN, ONLY WHERE PERMITTED
BY THE LOCAL JURISDICTION HAVING DIRECT AUTHORITY.
FPA2
2x4 & 2x6 2x8 & 2x10 2x12
WOOD
Fb (PSI)
WD11
WD9
WD10
WD8
WD5
WD6
WD7
2 TO 4
WD3
WD2
WD1
Fv (PSI)
Fc (PSI)
NO. 2 SYP
NO. 2 SYP
NO. 2 SYP
NO. 2 SYP
NO. 2 SYP
1"
EDGE 2" END
WD12
DIST
DIST
2" END
DIST
(4 NAILS/ft) (5 NAILS/ft) (6 NAILS/ft)
DIST
2" END
REVIEW ARCHITECTURAL REFLECTED CEILING PLANS AND SECTIONS FOR
SPECIAL CEILING CONDITIONS INCLUDING CEILING SLOPES, TROFFERS,
COFFERS, TRAYS, STEPS AND OTHER SPECIAL FEATURES.
WOOD CONSTRUCTION SHALL CONFORM TO AITC, NATIONAL DESIGN
SPECIFICATIONS AND THE APPLICABLE CODE. SEE NOTE D1 FOR APPLICABLE
BUILDING CODE.
HURRICANE CLIPS, JOIST HANGERS, POST CAPS AND BASES, BEAM
HANGERS AND OTHER STANDARD CONNECTIONS SHALL BE ADEQUATE
FOR LOADS. METAL CONNECTORS AND FASTENERS SHALL BE G185 HOT-
DIPPED GALVANIZED.
PROVIDE MEMBERS AS SCHEDULED:
WOOD IN CONTACT WITH MASONRY OR CONCRETE
SHALL BE PRESSURE-TREATED.
UNLESS NOTED OTHERWISE, MULTI-MEMBER WOOD RAFTERS, BEAMS AND
LEDGERS SHALL BE FASTENED TOGETHER WITH 10d COMMON NAILS (0.131"x3"
PNEUMATIC FRAMING NAILS ARE AN ACCEPTABLE ALTERNATE) IN EVENLY
SPACED STAGGERED PATTERNS AS SHOWN BELOW:
FOR THREE (OR MORE) PLY MULTI MEMBERS, THE NAILS SHALL BE
INSTALLED SUCCESSIVELY. FOR EXAMPLE, PLACE THE FIRST AND SECOND
MEMBERS TOGETHER AND ATTACH PER THE SPECIFIED NAIL SPACING, THEN
PLACE THE THIRD MEMBER AGAINST THE
SECOND AND REPEAT NAILING, AND SO ON. EXCEPT FOR LEDGERS, EACH
MEMBER SHALL BE FULL LENGTH.
JOISTS OR RAFTERS SHALL BE LATERALLY SUPPORTED AT ENDS BY SOLID
BLOCKING OR OTHER MEANS TO PREVENT ROTATION.
STANDARD WASHERS SHALL BE USED BETWEEN WOOD AND BOLT HEADS AND
NUTS. BOLTS AND SCREWS SHALL BE ASTM A307. ALL FASTENERS IN
CONTACT WITH TREATED WOOD SHALL BE G185 HOT-DIPPED GALVANIZED.
DOUBLE STUDS SHALL BE PROVIDED UNDER EACH END OF BEAMS AND ON EACH
SIDE OF OPENINGS TO 4'-0" IN WIDTH. TRIPLE STUDS SHALL BE PROVIDED EACH
SIDE OF OPENINGS UP TO 7'-0" IN WIDTH, UNLESS NOTED OTHERWISE.
HEADERS SHALL BE (2) 2x10'S FOR SPANS UP TO 4'-0" AND (2) 2x12'S FOR SPANS UP TO 7'-0".
MICROLAM BEAMS SHALL CONFORM TO NER 126 AND SHALL BE 2.0 E S.P. (Fb = 2925 PSI, E=2,000,000 PSI)
1"
EDGE
DIST
1"
EDGE
DIST
VISUALLY GRADED DIMENSION LUMBER
1,400,000
1,400,000
1,400,000
1,400,000
1,400,000
E (PSI)
JOIST, STUD & HEADERS
THICKNESS
(in)
WIDTH
(in)
2 TO 4
2 TO 4
2 TO 4
2 TO 4
(PER SOUTHERN FOREST PRODUCTS ASSOCIATION SUPPLEMENT No. 13)
Fb (PSI)
WD4
Fv (PSI)
Fc (PSI)
NO. 2 SYP
PROVIDE MEMBERS AS SCHEDULED:
VISUALLY GRADED TIMBERS
1,500,000
1,200,000
E (PSI)BEAMS & COLUMNS
5x5 & LARGER SELECT
STRUCTURAL
SYP
* INCLUDES SIZE FACTOR (C )F
(PER SOUTHERN FOREST PRODUCTS ASSOCIATION SUPPLEMENT No. 13)
COMMERCIAL
GRADE AND
SPECIES
COMMERCIAL
GRADE AND
SPECIES
* INCLUDES SIZE FACTOR (C )F
1'-0"
1'-0" 1'-0"
NAILING PATTERN DETAILS
ABBREVIATIONS
EXTERIOREXT
SHORT LEG BACK-TO-BACK
SPACE(S)
SQUARE
STEEL
THICK
TIE BEAM
TOPPING
SHORT WAY
SOUTHERN YELLOW PINE
SYMMETRICAL
STRUCTURAL
STRENGTH
STIFFENER
STANDARD
SHORT SLOTTED
STAINLESS STEEL
SPECIFICATIONS
TIE COLUMN
TEMPERATURE
TOP AND BOTTOM
WITH
UNLESS NOTED OTHERWISE
WORKING POINT
WATERSTOP
WELDED WIRE FABRIC
WALL FOOTING
WINDOW OPENING (MASONRY)
VERIFY IN FIELD
WOOD
TOP OF
TYPICAL
TRANSVERSE
SLAB ON GRADE
INSIDE DIAMETER
JT
K
KO
INT
JST
ID
IF
JOINT
KNOCK-OUT
KIP
JOIST
INSIDE FACE
INTERIOR
WWF
W/
WO
WS
WP
VIF
UNO
WD
WF
GALVANIZE(D)
HOLLOW STRUCTURAL SECTION
GROUT FILLED CELL(S) / COURSE
GENERAL CONTRACTOR
GLU-LAM BEAM
HOLLOW-CORE
FINISHED FLOOR
GAUGE
GALV
GLB
HORIZ
HP
HS
HSS
HC
HK
GC
GFC
GR
ga
GB
HORIZONTAL
HOOK
HEADED STUD
HIGH POINT
GRADE
GRADE BEAM
FLR
FT
FTG
FLG
FS
FMG
FDN
FF
FIN
F/
FBC
FLOOR
FLANGE
FAR SIDE
FRAMING
FOOTING
FOOT
FINISH
FLORIDA BUILDING CODE
FACE OF
FOUNDATION
TEMP
TYP
TRANS
TOPG
THK
T/
SYMM
T&B
SYP
TC
TB
SSL
STIFFR
STRL
STR
STD
SW
STL
SLBB
SPECS
SOG
SS
SQ
SP
STEPPED FOOTING
SLOPE
SIMILAR
SHEET
STEEL JOIST INSTITUTE
SAWCUT JOINT
SCHEDULE
STEEL DECK INSTITUTE
POWDER-ACTUATED
PERPENDICULAR
PRE-ENGINEERED METAL
POUNDS PER LINEAR FOOT
RADIUS POINT
PLYWOOD
PARTITION
REINFORCED CONCRETE
REFERENCE
REINFORCE(D) (ING)
REQUIRED
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
ROOM
RETURN
RADIUS
REQUIRE
ROOF
PANEL
PRECAST
PLATE
PLACES
LONG
POUND(S)
LINTEL
OVERALL
OPENING
LIVE LOAD
LOCATION
LONG WAY
LONG LEG BACK-TO-BACK
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LONG SLOTTED
LONGITUDINAL
LOW POINT
NEAR SIDE
NOT IN CONTRACT
OPPOSITE
OUTSIDE FACE
OUTSIDE DIAMETER
ON CENTER
NOT TO SCALE
OPPOSITE HAND
BELOWBLW
PLYWD
DEFORMED BAR ANCHOR
EDGE OF SLAB
EXPANSION JOINT
EQUAL SPACE(S) (ING)EQ SP
EXP
EOS
EW
ES
EQ
EL
EF
EJ
ENG
EA
EE
EXPANSION
ELEVATION
EQUAL
EACH SIDE
EACH WAY
ENGINEER
EACH
EACH FACE
EACH END
CTRD
DIAG
COORD
DWG
DBA
CSK
DN
DTL
DWL
DIA
DL
CY
CTR
DOWEL
DIAMETER
DIAGONAL
DOWN
DETAIL
DRAWING
DEAD LOAD
COORDINATE
COUNTER SINK
CUBIC YARD
CENTERED
CENTER
RP
SDI
SHT
SIM
SJI
SL
SJ
SF
SCH
RTN
RC
REF
REINF
REQ'D
REQ
RF
RM
PNL
PSF
PTN
R
PSI
CENTER TO CENTER
CONCRETE BEAM
CONCRETE COLUMN
COLD-FORMED STEEL
BOLTED TIE JOIST
CONSTRUCTION JOINT (OR
CONTROL JOINT)
CONSTRUCTION MANAGER
CONCRETE MASONRY UNIT
CAST-IN-PLACE
CC
CONC
CONT
CONN
COL
CLR
CONTR
CM
CMU
CIP
CFS
CJ
CONTRACTOR
CONNECTION
CONTINUOUS
CONCRETE
COLUMN
CLEAR(ANCE)
CENTERLINE
BTWN
BRDG
CANT
BRK
BRG
BOT
BS
C/C
CB
BTJ
BM
BP
BOTH SIDES
BETWEEN
CANTILEVER
BRICK
BEAM
BOTTOM
BASE PLATE
BRIDGING
BEARING
OH
PERP
PLF
PLS
PC
PAF
PEMB
OPNG
OPP
NS
NTS
OF
OD
OC
OA
NIC
ANCHOR BOLT
ARCHITECT(URAL)
ABOVE FINISH FLOOR
AMERICAN CONCRETE INSTITUTE
AUTOCLAVED AERATED CONCRETE
AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
AMERICAN IRON AND STEEL
AMERICAN SOCIETY OF TESTING
MATERIALS
AMERICAN WELDING SOCIETY
BLDG
A.I.S.I.
ARCH
ASTM
A.W.S.
B/
BB
AL
ALT
BUILDING
BOTTOM OF
BOND BEAM
ALUMINUM
ALTERNATE
INSTITUTE
AAC
ABV
A.C.I.
ADDL
AGGR
A.I.S.C.
AB
AFF
ADDITIONAL
AGGREGATE
ABOVE
LONG
LW
LP
LL
LLV
LOC
LNTL
LSL
LLBB
LLH
lb, #
LG
BUILDING
FASTENER(S)
MAS
MATL
MB
MBM
MC
MCJ
MECH
MEZZ
MFR
MIN
MISC
MO
MS
MTL
MASONRY
MATERIAL
MACHINE BOLT
METAL BUILDING MFR
MASONRY COLUMN
MASONRY CONTROL JT
MECHANICAL
MEZZANINE
MANUFACTURE(ER)
MINIMUM
MISCELLANEOUS
MASONRY OPENING
METAL STUD
METAL
MONOLITHIC EDGEME
MONOLITHIC FOOTINGMF
MONOLITHIC WALL FOOTINGMWF
PB PRE-CAST BEAM
VERTICALVERT
FD FLOOR DRAIN
SECTIONSECT
C, CL
P, PL
ANCHOR RODAR
MCN MOMENT CONNECTION
BLKG BLOCKING
ALLOWABLE STRESS DESIGNASD
LRFD LOAD & RESISTANCE FACTOR
DESIGN
HOT DIPPED GALVANIZEDHDG
OVERHEADOHD
SHEAR WALLSHW
MAX MAXIMUM
REINFORCED WITHR/W
L
L
COLD FORMED METAL FRAMINGCFMF
ROUGH OPENINGRO
GT GIRDER TRUSS
EXIST EXISTING
B O
R A ERB ILE
N
L I CENSE
F LO R I DA
P R
O F
E
S S
I O N A L E
N G
I N
E E
R
STATE OF
NO. 55996
2300 Maitland Center Parkway Suite 201 Maitland, FL 32751 p: 407 - 645 - 3423
EB: 5343
ENGINEER HEREBY EXPRESSLY RESERVES HIS COMMON LAW COPYRIGHT AND OTHER
PROPERTY RIGHTS IN THESE PLANS. THIS DESIGN AND DRAWINGS ARE NOT TO BE
REPRODUCED, CHANGED, COPIED OR ELECTRONICALLY DOWNLOADED OR OTHERWISE
DIGITALLY OBTAINED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST SECURING THE
EXPRESSED WRITTEN PERMISSION AND CONSENT OF "BBM STRUCTURAL". NEITHER MAY THESE
DRAWINGS BE ASSIGNED TO ANY PERSON, PERSONS OR COMPANY WITHOUT FIRST OBTAINING
SAID WRITTEN PERMISSION AND CONSENT.
BBM PROJECT #
A R C H I T E C T U R E
F
E
D
C
B
A
F
E
D
C
B
A sh ee t t itl e:
sheet number:
IF THIS SHEET MEASURES LESS THAN 42" x 30", IT HAS BEEN REDUCED scale:
drawn by:
designed by:
project no.:
issue date:
professional license no.:
name:
pr oj ec t a dd re ss cl ie nt n am e:
pr oj ec t s ta tu s:
pr oj ec t n am e:
This item has been digitally signed and sealed by Bora
Erbilen, P.E. per the date provided.
Printed copies of this document are not considered signed and sealed and the signature must be verified on the any electronic copies.
55996
Bora Erbilem P.E.
consultant:
client:
25138
/1
4/
:0 6:
P
M
3/4" = 1'-0"
S001
S
TR
U C
TU
R
A L
G E
N E
R A
L N
O
TE
S
JG
RC
2025-P004
11/14/25
C ity o f D el an d
N . F ra nk fo rt
A ve
. A ve
. D eL an d, F L
C ity o f D el an d
Ja ck so n
La ne
P ar k P av ill on
0%
C D
N O
D
E S
C R
IP
T
IO
N
D A
MASONRY
NOTES:
MASONRY CONSTRUCTION MATERIALS AND INSPECTIONS SHALL CONFORM TO
THE LATEST EDITION OF THE ACI BUILDING CODE REQUIREMENTS FOR
CONCRETE MASONRY STRUCTURES (TMS 402-2016), SPECIFICATIONS FOR
MASONRY STRUCTURES (TMS 602-2016) ASTM C476-19, ASTM C1019-20 AND
NCMA TEK 107.
STOPPING AND RESUMING WORK: RACK BACK 1/2-UNIT LENGTH IN EACH
COURSE. DO NOT TOOTH. CLEAN EXPOSED SURFACES OF SET MASONRY.
REMOVE LOOSE MASONRY UNITS AND MORTAR PRIOR TO LAYING FRESH
MASONRY.
REINFORCE MASONRY OPENINGS LESS THAN 2'-0" WIDE, WITH HORIZ JOINT REINF
PLACED IN (2) HORIZ JOINTS APPROXIMATELY 8" APART, IMMEDIATELY ABOVE
THE GROUT FILLED LINTEL AND IMMEDIATELY BELOW THE GROUT FILLED SILL.
EXTEND REINFORCING A MINIMUM OF 2'-0" BEYOND JAMBS OF THE OPENING
EXCEPT AT CONTROL JOINTS.
DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS.
DO NOT APPLY CONCENTRATED LOADS TO MASONRY WALLS FOR (7)
DAYS.
EXTEND ALL VERTICAL WALL REINFORCEMENT TO WITHIN 2" OF TOP OF WALL
OR BEAM UNLESS NOTED OTHERWISE. TERMINATE REINFORCING WITH
STANDARD ACI 90 DEGREE HOOK IF ROOF JOISTS AND/OR TRUSSES BEAR ON
TOP OF WALL AND THERE IS NO PARAPET. IF PARAPET EXISTS, HOOK IS NOT
REQUIRED.
JOB SITE MIXING OF GROUT SHALL NOT BE PERMITTED. TESTING SHALL
CONFORM TO ASTM C1019. SEE TEST MOLD DETAIL BELOW. SEE SCHEDULE
BELOW FOR COMPRESSIVE STRENGTH AND SLUMP REQUIREMENTS.
M21
M17
M16
M15
M12
CONCRETE BLOCKS SHALL CONFORM TO ASTM C-90. (f'm = 2000 PSI)
(2000 PSI ON THE NET AREA).
BLOCK SHALL NOT BE MOISTENED BEFORE GROUTING.
ALL MASONRY CROSS WEBS SHALL BE FULLY BEDDED IN MORTAR AROUND
CELLS TO BE GROUTED.
REINFORCE WALLS WITH LADDER TYPE (ASTM A-153, #9 GAGE WIRE) DEFORMED
REINFORCEMENT EQUAL TO DUR-O-WAL IN BED JOINTS AT 16" OC UNO, MEASURED
VERTICALLY. PLACE PER MFR'S INSTRUCTIONS. LAP ALL HORIZONTAL JOINT
REINFORCING 6" MIN.
GROUT PLACEMENT STOPPED FOR (1) HOUR OR MORE SHOULD BE STOPPED
1 1/2" BELOW THE TOP OF THE MASONRY UNIT TO PROVIDE A KEY FOR
SUBSEQUENT GROUTING.
TYPICAL VERTICAL REINFORCING SIZE AND SPACING SHALL BE ABOVE AND
BELOW ALL WALL OPENINGS.
TEMPORARY BRACING AND SHORING OF WALLS TO PROVIDE STABILITY DURING
CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
PROVIDE FILLED PRECAST U-LINTELS AS MANUFACTURED BY CAST- CRETE OR
APPROVED EQUAL WITH (2) #5 CONT AT ALL OPENINGS WHERE BEAMS ARE NOT
SHOWN, SCHEDULED OR NOTED 2'-0" WIDE AND GREATER. LINTELS SHALL HAVE
MINIMUM UNFILLED CAPACITY OF 400 lb/LF AND BEAR NOMINAL 8" (MIN 8") EACH
END ON A GROUT FILLED CELL. PROVIDE PRE-CAST LINTEL MFR'S STANDARD
TABULATED LOAD TABLES AS EVIDENCE THAT THE MINIMUM CAPACITIES AS
LISTED IN THE BEAM SCHEDULE ARE SATISFIED. REFER TO MASONRY WALL BEAM
SCHEDULE FOR TYPICAL PRECAST LINTEL SPANS AND DETAILS.
VERTICAL REINFORCING MUST HAVE A MINIMUM CLEARANCE OF 1/2" TO INSIDE
FACE. VERTICAL REINFORCEMENT IN WALLS SHALL BE SECURED AND
LATERALLY SUPPORTED AGAINST DISPLACEMENT AT INTERVALS NOT
EXCEEDING 192 x (BAR DIAMETER) OR 10 FT (WHICHEVER IS LESS) WHENEVER A
CLEANOUT IS REQUIRED. SEE GROUTING DETAIL NOTE FOR CLEANOUT
REQUIREMENTS.
M9
M14
M13
M11
M10
M6
M7
M5
M4
M3
M1
M2
IF WALL IS LAID UP NO GREATER THAN 5'-0" IN
HEIGHT ABOVE THE FOOTING OR PREVIOUS
GROUT POUR(S), A CLEAN-OUT HOLE SHALL NOT
BE REQUIRED. OTHERWISE, PROVIDE CLEAN-OUT
HOLE WITH MINIMUM SIZE OF 3"x3". OVERHANGING
MORTAR AND DEBRIS SHALL BE REMOVED FROM
INSIDE THE CELL WALLS. SEAL PRIOR TO
GROUTING BUT AFTER INSPECTION.
SEE NOTE M21 FOR GROUT PROPERTIES
GROUT FOR FILLED CELLS SHALL BE PLACED IN CONFORMANCE WITH ASTM C476-19
AND AS INDICATED BELOW:
M19
TYPICAL MASONRY DETAILS:M20
MORTAR SHALL COMPLY WITH ASTM C270, TYPE 'M' FOR RETAINING WALLS
AND WALLS BELOW GRADE, TYPE 'S' FOR TYPICAL WALLS. (COMPRESSIVE
STRENGTH = 2500 PSI AND 1800 PSI, RESPECTIVELY. SITE TESTED MORTAR
CUBES SHALL ACHIEVE A MINIMUM OF 80% OF THE DESIGN COMPRESSIVE
STRENGTH)
REFER TO ARCHITECTURAL DRAWINGS FOR WATERPROOFING DETAILS AT
MASONRY CONTROL JOINTS.
M18
M22
(4) 8x8x16 CMU BLOCKS
REQUIRED (FRONT BLOCK
REMOVED FOR CLARITY)3"x3"x1 5/8" WOOD BLOCK
COVER UNITS USING
ABSORPTIVE PAPER
TOWELLING W/ TAPE
GROUT TEST PRISM
MAX HEIGHT OF GROUT LIFT = 5'-0".
CONSOLIDATE BY MECHANICAL VIBRATION
PER ASTM C476-19. ONE OR MORE GROUT
LIFTS CONSTITUTE A GROUT POUR AND A
GROUT POUR EQUALS THE HEIGHT OF BLOCK
LAID UP AT ONE TIME.
STANDARD HOOK
(ALTERNATE SIDES)
DOWELS SAME AS
VERT BARS
VERT BAR CENTERED
IN FILLED CELL
L A P S
P L
IC
E
STOP VERTS 2" FROM TOP OF
WALL. HOOK MAY BE REQ'D,
SEE NOTE M17
JOINT REINF
SHALL BE
CONTINUOUS IN
BOTH DIRECTIONS
FILLED CELL W/ TYP WALL
REINF EACH SIDE OF MCJ
BOND BEAM REINF
CONTINUOUS AT MCJ
INTERSECTING
MASONRY WALLS
INTERSECTING
MASONRY WALLS
1/2" THROUGH-WALL
VERTICAL CONTROL JOINT
PRE-FABRICATED
"T" JOINT REINF
SEALANT - SEE ARCH
DWGS AND OR SPECS
HORIZ JOINT REINF @ 16"
OC VERT SPACING
FILLED CELL WITH TYP WALL
REINF EACH SIDE OF MCJ
3.
NOTES:
2.
1.
1/2" THROUGH-WALL
VERTICAL CONTROL JOINT
SEALANT - SEE ARCH
DWGS AND OR SPECS
MAXIMUM SPACING OF CONTROL JOINTS SHALL BE 1 1/2
x (WALL HEIGHT) OR 25'-0", WHICHEVER IS LESS.
THROUGH-WALL JOINT SHALL BE CONTINUOUS WITHOUT
INTERRUPTION FROM FOUNDATION TO TOP OF WALL.
TERMINATE TYPICAL HORIZONTAL JOINT
REINFORCING 2" FROM JOINT.
MINIMUM LAP SPLICES FOR REINFORCED CMU PER EIGHTH EDITION
(2023) FBC FOR LRFD DESIGNS.
#4 #5 #6 #7 #8
15" 23" 35" 48" 72" 82"
NOTES:
1.
2. #10 BARS SHALL BE SPLICED USING MECHANICAL CONNECTORS
AND SHALL ONLY BE ALLOWED IN 12" CMU.
#9 BARS ARE NOT ALLOWED IN 8" CMU BUT ACCEPTABLE FOR 10"
AND 12" CMU. MAXIMUM BAR DIAMETER SHALL NOT EXCEED ONE-
EIGHTH OF THE NOMINAL WALL THICKNESS.
#9
(NOTE 1)
#10
(NOTE 2)
CMU WALLS WITH CENTERED VERTICAL REINFORCING
#4 #5 #6 #7 #8
23" 36" 54" 63" 72" 82"
#9
(NOTE 1)
#10
(NOTE 2)
CMU WALLS WITH EACH FACE VERTICAL REINFORCING
3. EPOXY COATED BARS SHALL NOT BE USED.
1. BUTTER AROUND ALL CELLS THAT ARE TO BE FILLED WITH GROUT TO
ENSURE GROUT DOES NOT LEAK OUT.
L A P S
P L
IC
E
TEST MOLD (ASTM C-1019)
DETAIL - MASONRY GROUT
TYPICAL FILLED CELL
DETAILS
WALL INTERSECTION
WALL INTERSECTION
MAS CONTROL JOINT
(MCJ)
MCJ @ BOND BEAM
GROUTING DETAIL
DD
CC
BB
AA
2. DO NOT GROUT UNTIL MORTAR HAS SET SUFFICIENTLY TO WITHSTAND
THE PRESSURE OF THE GROUT. WAIT NOT LESS THAN 24 HOURS.
3. PLACE GROUT WITHIN 90 MINUTES FROM INTRODUCING WATER IN THE
MIXTURE AND PRIOR TO INITIAL SET.
4. MAXIMUM WALL HEIGHT FROM TOP OF FOOTING OR PREVIOUS GROUT
POURS LAID UP AT ONE TIME SHALL BE 4'-0".
5. THE MINIMUM CONTINUOUS UNOBSTRUCTED CLEAR AREA IN CELL TO
RECEIVE GROUT MUST BE NOT LESS THAN 3"x3". MORTAR FINS MUST
BE REMOVED AS BLOCK PLACEMENT PROCEEDS. MORTAR
DROPPINGS MUST BE KEPT OUT OF CELLS WHICH ARE TO BE
GROUTED.
D D
NOTES:
REINF IS CONTINUOUS
AT CONTROL JOINT IN
CONC TIE BEAM
ADJUST STIRRUP LOCATION
SLIGHTLY TO CLEAR JOINT
BY MIN 2"
3/8"W x 1"D VERT
(DUMMY) JOINT EACH
SIDE OF TIE BEAM
NTS
M A S O
N R
Y
A L
IG
N W
IT
H
C O
N T R
O L
J
IN
T STIRRUPS - SEE
SCH FOR SIZE
AND SPACING
SEE MASONRY NOTES ON GENERAL NOTE SHEETS FOR
HORIZONTAL JOINT REINFORCING AND OTHER ADDITIONAL
INFORMATION.
SEE FDN PLAN NOTES FOR REINFORCED FILLED CELL
SIZE & SPACING.
MULTIPLE FILLED CELLS MAY BE REQUIRED AT JAMBS.
ADDITIONAL BARS WILL BE SHOWN ON PLAN(S). IF NONE ARE
SHOWN, THEN A SINGLE TYPICAL REINFORCED JAMB CELL IS
SUFFICIENT.
SEE ARCHITECTURAL DRAWINGS FOR OPENING SIZES
AND LOCATIONS.
5.
4.
3.
2.
SPACING
TYPICAL
SPACING
TYPICAL
SEE DETAIL "CC" FOR LOCATING MASONRY CONTROL JOINTS.
CONTRACTOR SHALL SUBMIT MCJ PLAN TO ARCHITECT FOR
APPROVAL.
1.
TYP INTERIOR
NON-LOAD-BEARING
CMU WALL ON
THICKENED SLAB
WINDOW OPNG
(SEE NOTE 4)
TYP INTERIOR LOAD-BEARING
CMU WALL ON FOOTING
DOOR
OPENING
TYP EXTERIOR
LOAD-BEARING CMU
WALL ON FOOTING
S P A C
IN
G T Y P
IC
A L
SEE PLANS FOR ADD'L
FILLED CELLS REQ'D
AT OPENINGS (VARIES)
C WALL
PROVIDE ADD'L
REINFORCED
FILLED CELL
/8
INTERIOR NON-LOAD-
BEARING WALL ON
THICKENED SLAB
SEALANT - SEE
ARCH DWGS AND
OR SPECS EXTERIOR LOAD-
BEARING WALL
(3) REINF CELLS
AT CORNERS, TYP
(SEE
NOTE 4)
ILLUSTRATIVE PLAN OF VARIOUS
CMU WALL CONDITIONS
MCJ @ TIE BEAM
& NON-LOAD-BRG WALLS
INTERSECTION OF LOAD-BRG
EE BB
AA
CC
EE
L
ANY MASONRY THAT IS BELOW GRADE SHALL BE FULLY GROUTED UP TO
FINISHED FLOOR.
M8
MCJ SEE DETAIL CC NOTE 4
4. MASONRY CONTROL JOINTS IN CMU WALLS SHALL
NOT BE LOCATED WITHIN 16" OF ANY JAMB.
FILLED CELL, PRECAST
LINTELS & BOND BEAMS
LOCATION SLUMP
28 DAY
STRENGTH
COARSE
AGGREGATE
HOLLOW METAL FRAMES, 4"
PARTITION BLOCK
2500 PSI 8" TO 11" 3/8"
2500 PSI 8" TO 11" NONE
NOTES:
ALL MASONRY GROUT SHALL CONFORM TO ASTM C 476.
COURSE AGGREGATES SHALL CONFORM TO ASTM C 404.
DO NOT TEST GROUT USING CYLINDERS AS THIS IS CONTRARY
TO ASTM C476-19 AND IS STRICTLY PROHIBITED.
1.
2.
3.
MASONRY GROUT SHALL HAVE THE FOLLOWING PROPERTIES:
GRID LINE
EXISTING
MATCH LINE
HIDDEN
CONTINUOUS
DASHED
TYPICAL LINETYPES
SECTION CUTS
GRID ID
REVISION MARK
TYPICAL PLAN
KEYNOTE SYMBOL
SECTION & DETAIL ID
ELEVATION SYMBOL
MATERIALSCHANGE IN
SLAB ELEVATION
PLAN HATCHES
SECTION HATCHES
SHEET
NUMBER
NUMBER FOR SECTION
LETTER FOR DETAIL
OR DETAIL OCCURS
SHEET ON WHICH SECTION
LETTER FOR DETAIL
NUMBER FOR SECTION
SCALE
CONCRETE
EARTH
STEEL
PRECAST
CONCRETE
GROUT
8" LOAD-BRG
CMU WALLS
NON-LOAD-
BRG CMU
WALLS
SYMBOL LEGEND
TITLE
MOMENT CONNECTION
B O
R A ERB ILE
N
L I CENSE
F LO R I DA
P R
O F
E
S S
I O N A L E
N G
I N
E E
R
STATE OF
NO. 55996
2300 Maitland Center Parkway Suite 201 Maitland, FL 32751 p: 407 - 645 - 3423
EB: 5343
ENGINEER HEREBY EXPRESSLY RESERVES HIS COMMON LAW COPYRIGHT AND OTHER
PROPERTY RIGHTS IN THESE PLANS. THIS DESIGN AND DRAWINGS ARE NOT TO BE
REPRODUCED, CHANGED, COPIED OR ELECTRONICALLY DOWNLOADED OR OTHERWISE
DIGITALLY OBTAINED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST SECURING THE
EXPRESSED WRITTEN PERMISSION AND CONSENT OF "BBM STRUCTURAL". NEITHER MAY THESE
DRAWINGS BE ASSIGNED TO ANY PERSON, PERSONS OR COMPANY WITHOUT FIRST OBTAINING
SAID WRITTEN PERMISSION AND CONSENT.
BBM PROJECT #
A R C H I T E C T U R E
F
E
D
C
B
A
F
E
D
C
B
A sh ee t t itl e:
sheet number:
IF THIS SHEET MEASURES LESS THAN 42" x 30", IT HAS BEEN REDUCED scale:
drawn by:
designed by:
project no.:
issue date:
professional license no.:
name:
pr oj ec t a dd re ss cl ie nt n am e:
pr oj ec t s ta tu s:
pr oj ec t n am e:
This item has been digitally signed and sealed by Bora
Erbilen, P.E. per the date provided.
Printed copies of this document are not considered signed and sealed and the signature must be verified on the any electronic copies.
55996
Bora Erbilem P.E.
consultant:
client:
25138
/1
4/
:0 6:
P
M
3/4" = 1'-0"
S002
S
TR
U C
TU
R
A L
G E
N E
R A
L N
O
TE
S
JG
RC
2025-P004
11/14/25
C ity o f D el an d
N . F ra nk fo rt
A ve
. A ve
. D eL an d, F L
C ity o f D el an d
Ja ck so n
La ne
P ar k P av ill on
0%
C D
N O
D
E S
C R
IP
T
IO
N
D A
MWF20
MWF20
M W
F
M W
F
WC1
MF46 MF46 MF46
MF46 MF46 MF46
MF46 MF46 MF46
WC1 WC1
WC1 WC1 WC1
WC1 WC1 WC1
1 2 3
A
B
E
19' - 4"
9' - 8" 9' - 8"
20' - 0 3/8"
4"
B1
S201
B1
S201
B3
S201
C
D
FOUNDATION PLAN NOTES:
MAINTAIN STRUCTURAL SLAB THICKNESS AT ALL FLOOR SLOPES
AND DEPRESSIONS.
TYP SPACING OF FILLED CELLS SHALL APPLY
ABOVE AND BELOW OPENINGS ALSO.
REINF LOAD-BEARING CMU WALLS WITH #5 VERT BAR
CENTERED IN GROUT-FILLED CELL AT ENDS, CORNERS AND AT
MAX SPACING OF 32" OC. PROVIDE (1) REINF CELLS AT ALL
GIRDER BEARING LOCATIONS WHERE A TIE COLUMN IS NOT
CALLED OUT. ADDITIONAL FILLED CELLS REQUIRED AT JAMBS
ARE SHOWN THUS " " ON EACH STRUCTURAL PLAN. SEE
"ILLUSTRATIVE PLAN OF VARIOUS CMU WALL CONDITIONS" ON
SHEET S002 FOR ADDITIONAL REQUIRED FILLED CELLS AND
OTHER INFORMATION.
ALL FTGS ARE CENTERED BENEATH BEARING
WALLS AND COLUMNS (TYP, UNO).
STEP AND/OR LOWER FOUNDATIONS WHERE SHOWN AND AS
NECESSARY TO AVOID INTERFERENCE WITH OTHER TRADES.
SEE CONCRETE GENERAL NOTES FOR DETAILS AND SECTIONS.
PARTICULAR ATTENTION SHALL BE PAID TO DOWNSPOUTS
ENSURING THAT PROPER ACTIONS HAVE BEEN TAKEN TO
PREVENT PIPES FROM CONFLICTING WITH THE FOUNDATION
SYSTEM.
ALL CMU BEARING WALLS ARE 8" (TYP, UNO).
T/ SLAB EL = 100'-0" (TYP, UNO). REFERENCE ONLY - SEE
CIVIL DWGS FOR ACTUAL ELEVATION.
FLOOR SLAB SHALL BE 4" THICK CONCRETE REINF WITH
6x6-W1.4xW1.4 WWF. UNO IN ARCHITECTURAL
SPECIFICATIONS, PROVIDE CLASS A (MIN 10 MIL) VAPOR
RETARDER (ASTM E 1745-11) ON COMPACTED SUBGRADE.
SEE "SLAB-ON-GRADE DETAILS" ON SHEET S201 FOR
PLACEMENT OF REINF.
LOCATION OF MASONRY CONTROL JOINTS (MCJ) SHALL BE
COORDINATED WITH ARCHITECTURAL DRAWINGS AND
SHALL NOT EXCEED REQUIREMENTS OUTLINED IN NOTE M20
ON SHT S002. FOR ADDITIONAL FILLED CELLS REQUIRED
AT MASONRY CONTROL JOINTS AND NOT SHOWN ON
FOUNDATION PLANS, SEE "ILLUSTRATIVE PLAN OF VARIOUS
CMU WALL CONDITIONS" ON SHT S002. SUBMIT MCJ PLAN
TO ARCHITECT FOR APPROVAL.
NOTE TO GC:
SEE SHEETS S001 AND S002 FOR STRUCTURAL GENERAL NOTES.
12.
11.
9.
8.
7.
6.
5.
4.
3.
2.
1.
T/ WALL FTG EL = 98'-8" (TYP, UNO).
T/ COL FTG EL = 98'-8" (TYP, UNO). 13. THE CONTRACTOR SHALL COORDINATE ALL UNDERGROUND
UTILITIES, PIPES, ETC...WITH THE FOUNDATION PLAN AND
FOUNDATION ELEVATIONS. FOOTING PENETRATION DETAILS
MAY BE FOUND IN THE CONCRETE AND REINFORCING SECTION
OF THE STRUCTURAL GENERAL NOTES.
SEE SHEET S401 FOR SCHEDULED PRECAST BEAMS (PB)
REQUIRED AT ALL MASONRY OPENINGS, UNO. PB'S SHALL BE
PROVIDED FOR ALL OPENINGS BASED ON THE PB SPAN AS
INDICATED IN SCHEDULE.
10.
FOUNDATION PLAN KEY NOTES:
(2) #4x4'-0" LONG @ 3" OC PLACED 2" CLR FROM
CORNER, CENTERED IN SLAB (TYP).
FOUNDATION LEGEND:
INDICATES WOOD COLUMN. SEE B3/S201 FOR INFO.
INDICATES PAD FOOTING. SEE FOUNDATION
SCHEDULE ON SHEET S401 FOR INFO.
INDICATES WALL FOOTING. SEE FOUNDATION
SCHEDULE ON SHEET S401 FOR INFO.
WC
F
WF
INDICATES MASONRY CONTROL JOINT. SEE M20 ON
GENERAL NOTE SHEET S002 FOR INFO.
MCJ-
SLAB DEPRESSION, SEE DETAIL F4/S201. REFERENCE
ARCH DWGS FOR EXACT SIZE, LOCATION AND DEPTH OF
DEPRESSION.
B O
R A ERB ILE
N
L I CENSE
F LO R I DA
P R
O F
E
S S
I O N A L E
N G
I N
E E
R
STATE OF
NO. 55996
2300 Maitland Center Parkway Suite 201 Maitland, FL 32751 p: 407 - 645 - 3423
EB: 5343
ENGINEER HEREBY EXPRESSLY RESERVES HIS COMMON LAW COPYRIGHT AND OTHER
PROPERTY RIGHTS IN THESE PLANS. THIS DESIGN AND DRAWINGS ARE NOT TO BE
REPRODUCED, CHANGED, COPIED OR ELECTRONICALLY DOWNLOADED OR OTHERWISE
DIGITALLY OBTAINED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST SECURING THE
EXPRESSED WRITTEN PERMISSION AND CONSENT OF "BBM STRUCTURAL". NEITHER MAY THESE
DRAWINGS BE ASSIGNED TO ANY PERSON, PERSONS OR COMPANY WITHOUT FIRST OBTAINING
SAID WRITTEN PERMISSION AND CONSENT.
BBM PROJECT #
A R C H I T E C T U R E
0 4'
1/8" = 1'-0" GRAPHIC SCALE
8' 16' 24' 32'
N
F
E
D
C
B
A
F
E
D
C
B
A sh ee t t itl e:
sheet number:
IF THIS SHEET MEASURES LESS THAN 42" x 30", IT HAS BEEN REDUCED scale:
drawn by:
designed by:
project no.:
issue date:
professional license no.:
name:
pr oj ec t a dd re ss cl ie nt n am e:
pr oj ec t s ta tu s:
pr oj ec t n am e:
TRUE
NORTH
This item has been digitally signed and sealed by Bora
Erbilen, P.E. per the date provided.
Printed copies of this document are not considered signed and sealed and the signature must be verified on the any electronic copies.
55996
Bora Erbilem P.E.
consultant:
client:
25138
/1
4/
:0 6:
P
M
As indicated
S101
FO
U
N D
A
TI
O N
P
LA
N
JG
RC
2025-P004
11/14/25
C ity o f D el an d
N . F ra nk fo rt
A ve
. A ve
. D eL an d, F L
C ity o f D el an d
Ja ck so n
La ne
P ar k P av ill on
0%
C D
SCALE: 1/8" = 1'-0"S101
1 FOUNDATION PLAN
N O
D
E S
C R
IP
T
IO
N
D A
1 2 3
A
B
E
19' - 4"
9' - 8" 9' - 8"
TB1 RAKED
@ T/ WALL
TB1 RAKED
@ T/ WALL
B B
T
W
A L L
B B
T
W
A L L
-P
L Y
X S
Y P N o .2
-P
L Y
X
S Y P N o .2
-P
L Y
X
S Y P N o .2
-P
L Y
X
S Y P N o .2
X S
Y P N o .2
C
B1
S301
B3
S301
B4
S301
B3
S301
B1
S301
B4
S301
B8
S301
0"
C
D
C1
S301
C3
S301
2-PLY 2X12 SYP No.2
2-PLY 2X12
SYP No.2
WOOD ROOF FRAMING PLAN NOTES:
WOOD ROOF FRAMING PLAN KEY NOTES:
DIAPHRAGM BLOCKING: UNO ON PLANS, PROVIDE
DIAPHRAGM BLOCKING AT EDGES OF ALL
OPENINGS IN THE DIAPHRAGM.
REFER TO ARCHITECTURAL DRAWINGS FOR FRAMED
DOWN CEILINGS, VOLUME CEILINGS AND OTHER INTERIOR
TREATMENTS.
ROOF DECK SHALL BE 5/8" A.P.A. RATED, EXPOSURE "1" TYPE
PLYWOOD SHEATHING WITH 40/20 (MIN) SPAN RATING
CONNECTED TO WOOD TRUSSES WITH 10d COMMON NAILS
@ 6" OC EVERYWHERE.
SEE ARCHITECTURAL BUILDING SECTIONS, STRUCTURAL
FRAMING PLANS AND TRUSS ELEVATIONS FOR ROOF
PITCHES (TYP).
OVERHANGS MAY VARY. SEE STRUCTURAL FRAMING
PLAN(S) AND ARCHITECTURAL BUILDING SECTIONS AND
WALL SECTIONS.
BEARING PLATE HEIGHTS VARY. SEE ARCHITECTURAL
BUILDING SECTIONS, WALL SECTIONS AND STRUCTURAL
FRAMING PLAN(S) FOR BEARING HEIGHTS.
PROVIDE SHEATHING SUPPORT CLIPS BETWEEN TRUSSES AT
UNBLOCKED PANEL EDGES (SIMPSON PSCL OR EQUAL).
COORDINATE SIZE AND LOCATION OF ROOFTOP
UNITS WITH MECHANICAL DWGS (IF REQUIRED).
9.
8.
7.
5.
4.
3.
2.
1.
SIMPSON CJT3Z EACH LAND OF BEAM UNO.
MASONRY BOND BEAMS AND TIE BEAMS THAT ARE
INDICATED ON THE PLAN SHALL BE CONTINUOUS FOR THE
ENTIRE LENGTH OF THE WALL, UNO.
10.
BLOCKING SHALL BE PROVIDED UNDER ALL HIPS &
VALLEYS WHERE DISCONTINUOUS DECK ENDS ARE NOT
SUPPORTED BY A TRUSS.
6.
ROOF LEGEND:
INDICATES BOND BEAM. SEE SCHEDULE
ON SHEET S401 FOR INFO.
INDICATES TIE BEAM. SEE SCHEDULE ON
SHEET S401 FOR INFO.
BB
TB
ROOF DESIGN LOADS
DEAD LOAD
NOTES:
1.
2.
LIVE LOAD
SEE TABLE ON SHEET S401 FOR GROSS UPLIFT
LOADS.
SEE PLAN FOR CONCENTRATED LOADS.
15 PSF 20 PSF
(UNREDUCIBLE)
2 CONNECT WOOD BEAM TO CMU WALL WITH SIMPSON HU212-2 HANGER.
3 SIMPSON APHH610 AT BEAM END W/ APVA6 AT TOP OF BEAM.
1 2 3
A
B
E
C
D
19' - 4"
9' - 8" 9' - 8"
BB2 @ T/ BEAM EL 109'-4"
TB1 RAKED
@ T/ WALL
B4
S301
B4
S301
B8
S301 6X12 SYP No.2, T/ EL 109'-4"
6X12 SYP No.2, T/ EL 109'-4"
6X12 SYP No.2, T/ EL 109'-0"
C3
S301
1 TYP
1TYP
B O
R A ERB ILE
N
L I CENSE
F LO R I DA
P R
O F
E
S S
I O N A L E
N G
I N
E E
R
STATE OF
NO. 55996
2300 Maitland Center Parkway Suite 201 Maitland, FL 32751 p: 407 - 645 - 3423
EB: 5343
ENGINEER HEREBY EXPRESSLY RESERVES HIS COMMON LAW COPYRIGHT AND OTHER
PROPERTY RIGHTS IN THESE PLANS. THIS DESIGN AND DRAWINGS ARE NOT TO BE
REPRODUCED, CHANGED, COPIED OR ELECTRONICALLY DOWNLOADED OR OTHERWISE
DIGITALLY OBTAINED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST SECURING THE
EXPRESSED WRITTEN PERMISSION AND CONSENT OF "BBM STRUCTURAL". NEITHER MAY THESE
DRAWINGS BE ASSIGNED TO ANY PERSON, PERSONS OR COMPANY WITHOUT FIRST OBTAINING
SAID WRITTEN PERMISSION AND CONSENT.
BBM PROJECT #
A R C H I T E C T U R E
1'-0" = 1'-0" GRAPHIC SCALE
0 3"2"1" 4"½"
F
E
D
C
B
A
F
E
D
C
B
A sh ee t t itl e:
sheet number:
IF THIS SHEET MEASURES LESS THAN 42" x 30", IT HAS BEEN REDUCED scale:
drawn by:
designed by:
project no.:
issue date:
professional license no.:
name:
pr oj ec t a dd re ss cl ie nt n am e:
pr oj ec t s ta tu s:
pr oj ec t n am e:
This item has been digitally signed and sealed by Bora
Erbilen, P.E. per the date provided.
Printed copies of this document are not considered signed and sealed and the signature must be verified on the any electronic copies.
55996
Bora Erbilem P.E.
consultant:
client:
25138
/1
4/
:0 6:
P
M
As indicated
S102
R O
O F
FR
A
M
IN
G P
LA
N
JG
RC
2025-P004
11/14/25
C ity o f D el an d
N . F ra nk fo rt
A ve
. A ve
. D eL an d, F L
C ity o f D el an d
Ja ck so n
La ne
P ar k P av ill on
0%
C D
SCALE: 1/8" = 1'-0"S102
D5 ROOF FRAMING PLAN
SCALE: 1/8" = 1'-0"S102
D2 LOW FRAMING PLAN
N O
D
E S
C R
IP
T
IO
N
D A
8"
NOTE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .