This document is a detailed foundation design drawing for a 40 ft. 2400 SWRD S.S. (Self-Supporting) Tower located at Mount Perkins, Arizona, prepared by Sabre Industries for Commdex LLC. The technical drawing provides comprehensive specifications for the tower foundation, including precise dimensions, reinforcing steel schedules, and embedment steel requirements. The plan view and elevation view show a 9'-0" wide foundation with specific anchor bolt placement and alignment details.

Key technical specifications include: 10.5 cubic yards of concrete required, total rebar weight of 908 lbs (454 lbs each for pad top and bottom reinforcing), and 12 anchor bolt assemblies and 2 anchor bolt templates. The drawing includes base reaction calculations for wind/ice and seismic loading scenarios, with specific shear, axial, and moment values for the total foundation and individual footing. General notes specify concrete requirements (4500 PSI compressive strength), rebar cover, and foundation design assumptions based on presumptive clay soil conditions.