B08_Attachment_6_-__Lassen_County_Design_Criteria.pdf

PDF 174 KB Posted

Attached to
ELFO LITCHFIELD MAINTENANCE SHOP NEW
Solicitation number
140L1222R0010
Issued by

About this file

This document provides building codes and design standards for Lassen County, California. It outlines that Lassen County enforces the 2019 versions of the California Building Code, California Residential Code, California Green Building Standards Code, California Mechanical Code, California Electrical Code, California Plumbing Code, and California Energy Code. Snow load requirements and structural design criteria are also provided, including seismic category D, allowable soil bearing pressure of 1,500 psf unless otherwise justified, and minimum footing depth of 18 inches below finished grade. Ice barrier underlayment protection is required countywide per specified codes.

The related federal contract opportunity is for the Eagle Lake Field Office Litchfield Maintenance Shop project. The solicitation number is 140L1222R0010 and is issued by the Department of the Interior Bureau of Land Management California Region. No further details are provided on required products or services, response dates, or other salient information.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Exhibit 4

Lassen County Building Codes and Design Standards

S:\PLA\Forms\BUILDING DIVISION FORMS

Building Codes and Design Criteria

DEPARTMENT OF PLANNING AND BUILDING SERVICES

707 Nevada Street, Suite 5 · Susanville, CA 96130-3912

(530) 251-8269 · (530) 251-8373 (fax) www.co.lassen.ca.us

Effective January 1, 2020 The California Building

Standards Commission adopted the enforcement of the

2019 California Building Standards Code, Title 24 of the

California Code of Regulations.

Building Design Criteria:

Lassen County enforces the following codes:

2019 California Building Code (CBC)

2019 California Residential Code (CRC)

2019 California Green Building Standards Code

(CGBSC)

2019 California Mechanical Code (CMC)

2019 California Electrical Code (CEC)

2019 California Plumbing Code (CPC)

2019 California Energy Code

2019 California Existing Building Code

2019 California Historical Building Code

Lassen County Code is available at:

http://www.qcode.us/codes/lassencounty/

Snow Load Requirements:

Please call or email our office for ROOF* snow load requirements. (530) 251-8269 landuse@co.lassen.ca.us

Please provide the Assessor’s Parcel Number or address.

* This Department only provides roof snow load and does not provide the ground snow load. Roof snow loads can be converted to ground snow loads in accordance with ASCE 7-16 Chapter 7. On a flat roof, roof snow load may be converted to ground snow load by dividing the roof snow load by 0.7. Conversely, ground snow load may be converted to roof snow load by multiplying the ground snow load by 0.7 (again see ASCE 7-16 for specific information).

In accordance with CBC Section 2308.2.3, conventional light frame construction is prohibited in all areas of

Lassen County with a roof snow load of more than 35 lbs/sqft, and CRC section R301.2.3 requires engineering when roof snow load (flat roof) is more than 49 lbs/sqft or more.

Structural Design Criteria:

Commercial

Wind Speed: 75 mph, ASD (3 second gust)

96 mph, Ultimate

Wind Exposure Category: C (unless B can be justified by a recognized engineering study)

Seismic Category: D

Allowable Design Soil Bearing Pressure:

1,500 psf (unless justified by a geotechnical investigation report)

Footing Depth:

Minimum 18” below finished grade.

Residential

Wind Speed: 85 mph, ASD (3 second gust)

110 mph, Ultimate

Wind Exposure Category: C (unless B can be justified by a recognized engineering study)

Seismic Category: D

Allowable Design Soil Bearing Pressure:

1,500 psf (unless justified by a geotechnical investigation report)

Footing Depth:

Minimum 18” below finished grade.

Ice barrier underlayment protection (Ice Dam

Protection) is required in all areas of Lassen County.

See CRC Table R301.2 (1), CRC Section R905.1.2 and CBC Section 1507.1.2. Ice dam protection is not required for metal roofs or unconditioned spaces

(e.g. garages, and shops).

http://www.qcode.us/codes/lassencounty/ jshobe Rectangle

EX4 Cover.pdf
Exhibit 4
Lassen County Building Codes and
Design Standards