B08_Attachment_13_-_Project_Design_-_Combined.pdf

PDF 6 MB Posted

Attached to
Replace HVAC at Maintenance & Curatorial Bldgs - S Federal contract opportunity
Solicitation number
140P9724R0010
Issued by
Department of the Interior National Park Service Alaska Region

About this file

This document appears to be an attachment related to a federal contract opportunity. The attachment contains a project design drawing for the replacement of HVAC systems at Maintenance and Curatorial Buildings in Skagway, Alaska. The related federal contract opportunity is Solicitation Number 140P9724R0010 to "Replace HVAC at Maintenance & Curatorial Bldgs - Skagway AK", issued by the Department of the Interior National Park Service Alaska Region. The drawing shows the layout and specifications for the HVAC system replacement, including the types of heating, gypsum, and wood components to be used. No additional details about the contract requirements, pricing, or response/award dates are provided in this specific document.

View the file

Other files for this federal contract opportunity

Other files attached to Replace HVAC at Maintenance & Curatorial Bldgs - S, newest first.
File Type Posted
B08_Attachment_2_-_Calculations.pdf PDF
B08_Attachment_10_Payment_Bond.pdf PDF
Sol_140P9724R0010.pdf PDF
B08_Attachment_5_-_CloseoutandOM_KLGO_Mech_and_Elect_10_12.xls XLS spreadsheet
B08_Attachment_11_Performance_Bond.pdf PDF
B08_Attachmen_12_-_Subcontracting___Worksheet.xlsx XLSX spreadsheet
B08_Attachmen_12_-_Subcontracting___Worksheet_1.xlsx XLSX spreadsheet
B08_Attachment_3_-_Curatorial_Photos.pdf PDF
B08_Attachment_4__KLGO_248830_CM-16_Submittal_Form.doc DOC document
B08_Attachment_1_Combo_Div_1___Specs.pdf PDF
B08_Attachment_7__ITM_Hot_Work_Permit.pdf PDF
B08_Attachment_6_-_SubmittalList-KLGO_Mech_and_Elect_3_14_24.xls XLS spreadsheet
B08_Attachment_9_Past_Performance_Questionnaire_Aug_2021.doc DOC document
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0-----------------------------------------------------------------------------------------------------------

N

- 1" FOS/R

- I

CT: J:>

PAINT

� (f S� p> E

":l Bil CT: 2" HGR ,b [ --- CT:

�- r:1 ,-./

�HGS ;_

(T) ! rl I-

-HGR :- '

2" HGR 2" HGS WOOD 1" HGS l

I 3/4" HGR-I ,.-,-{'T

�FINSIH

Jl �

�1" HW

1-1/2" cw

: II

S�E L

� BATH

CD, �,.

,.1fa � Mfi LY V)O".

GG

:r::r:

n �( )� C

-- u --- ,CD ·-i--L--: �

" HGR

� HGS / I

_j__l_ /( _j__j_

(T) 00 _oo -- C) �-l's

HGS ;_

HGR :-

I

I w:

I I

I I

I L I

HGR-

HGS-

- 2" HGR - 2" HGR

� 1" HGS/R

1" HGS 1-1/4" HGS

DEMOLISH

THERMOSTATS ATTIC ACCESS HATCH

(TYP) OPEN OFFICE

[IIl]

2" HGS

1-1/4" HGR l

,.Ll_' '

�<1'�, )�

_,. - l":l

I

CARPENTRY

SHOP

[II[]

1,100 GALLON FUEL

TANK TO REMAIN,

DEMOLISH FUEL TANK

ALARM

HGS ;_

HGR :-

,.Ll_' ' eft' •• 0,:V) ('.>C) c:r:

1-1/4" HGR

1-1/2" HGS �

µ [ill]

1-1/2" HGR - 3/4" HGS/R

1-1/2" HGS _ CT:

CD

J

CD

n ---------

HGR � ,_

HGS _j__j_ � i:::

00 - --

-� 1" HGR 1-1/4" HGS

I

, ... 1" HGS 1-1/4" HGR

CCt1 GG 3/4" cw I

I :- HGS�- 4 IIGR l --- ---

I

L __

��--. HGR .

- -- -HGS---1.----- ----tl

MAINT ENANCE BUI LDING D EMO LITION PLAN

1/8" = 1 '-0"

- FINNED TUBE TO

REMAIN (TYP)

GENERAL...SIORAGE

W2J

GENERAL NOTES:

A. THE INFORMATION SHOWN ON THIS DRAWING IS TAKEN FROM AS-BUILT

DRAWINGS AND A NON-DESTRUCTIVE WALK THROUGH OF THE FACILITY. THE

CONTRACTOR SHALL FIELD VERIFY ALL ITIEMS SCHEDULED FOR DEMOLITION

PRIOR TO START OF WORK.

B. DASHED OR DOTTED LINES INDICATE ITEMS BEING REMOVED. SOLID LINES

INDICATE EXISTING ITEMS TO REMAIN.

C. DEMOLITION WORK ON THIS PAGE IS ONLY IN REGARDS TO SYSTEMS BEING

WORKED ON. IF ADJACENT SYSTEMS REQUIRE MODIFICATIONS FOR WORK TO

BE COMPLETE, CONTRACTOR TO COORDINATE CHANGES WITH NPS COR.

D. CONTRACTOR TO CLEAN ALL DUCTWORK IN ACCORDANCE WITH SPECIFICATION

23 45 50. CONTRACTOR TO REFER TO EXHIBIT DRAWINGS FOR EXTENT OF

DUCTWORK, INCLUDING BUT NOT LIMITED TO ROUTING, SIZING, AND

QUANTITIES.

E. CONTRACTOR MAY PROPOSE VALUE ENGINEERING DEMOLITION MOD IF

APPLICABLE.

F. DEMOLISH UNIONS, ISOLATING VALVES, BALANCE VALVES, AND CONTROL

VALVES ON ANY EXISTING TERMINAL HEATING UNIT TO REMAIN.

SHEET NOTES: <1]

1. FOR ENLARGED VIEW, SEE - ���

2. FOR ENLARGED VIEW, SEE - ½l o

3. ADDITIVE OPTION #1: DEMOLISH MECHANICAL EQUIPMENT AND ASSOCIATED

APPURTENANCES BACK TO UPSTREAM OF ISOLATING VALVES. DEMOLISH

BRACING AND SUPPORTS, UNLESS OTHERWISE ALLOWED TO REMAIN FROM

VALUE ENGINEERING MOD.

AREA OF WORK

_K_E _Y_P_LA_N ____ flv{{

NO SCALE

z 0-z w a::

_J z :r:

w

:r:

en a::

_J

(.9

REVISIONS:

DRAWN BY: ARN/PDQ

CHECKED BY: AWW

DATE 3/14/24

JOB NUMBER: M2182

DWG FILE: MSERIES

DRAWING TITLE:

FIRST FLOOR

MAINTENANCE BUILDING

MECHANICAL DEMOLITION

SHEET:

M101

AT

IO

N

AL

P

AR

K

SE

R

VI

C

E

W

ES

T

5T H

A

VE

N U

E, AN

C H

O R

AG

E, A K

G O

LD

R

U

SH

M

EC

H

AN

IC

AL

R

EN

O

VA

TI

O

N

3/14/24

M2182

An ch or ag e, A

K

Ph on e (9

) 2

-0

C or po ra te N o.

: A

EC

C

W es t F ire we ed

L an e, S ui te

S

ME

CH

AN

ICA

L A

ND

EL

EC

TR

ICA

L C

ON

SU

LT

ING

EN

GI

NE

ER

S E ng in ee rin g, In c.

R

A

3/14/24

LEGEND

1 MAIN BUILDING - ONE-LINE DIAGRAM

NO SCALE

2 GARAGE - ONE-LINE DIAGRAM

NO SCALE 3 CURATORIAL - ONE-LINE DIAGRAM

NO SCALE

E001

ELECTRICAL PLANS

CSZ

SB

ESERIES

IO

N

AL

P

AR

K

SE

R

VI

C

E

W

ES

T

5T H

A

VE

N U

E, AN

C H

O R

AG

E, A K

G O

LD

R

U

SH

M

EC

H

AN

IC

AL

R

EN

O

VA

TI

O

N

3/14/24

M2182

An ch or ag e, A

K

Ph on e (9

) 2

-0

C or po ra te N o.

: A

EC

C

W es t F ire we ed

L an e, S ui te

S

ME

CH

AN

ICA

L A

ND

EL

EC

TR

ICA

L C

ON

SU

LT

ING

EN

GI

NE

ER

S E ng in ee rin g, In c.

R

A

3/14/24

1 DEMOLITION PLAN - BASE BID

1/8" = 1'-0"

GENERAL NOTES

E101

ELECTRICAL DEMOLITION

PLAN - BASE BID

CSZ

SB

SHEET NOTES

IO

N

AL

P

AR

K

SE

R

VI

C

E

W

ES

T

5T H

A

VE

N U

E, AN

C H

O R

AG

E, A K

G O

LD

R

U

SH

M

EC

H

AN

IC

AL

R

EN

O

VA

TI

O

N

3/14/24

M2182

An ch or ag e, A

K

Ph on e (9

) 2

-0

C or po ra te N o.

: A

EC

C

W es t F ire we ed

L an e, S ui te

S

ME

CH

AN

ICA

L A

ND

EL

EC

TR

ICA

L C

ON

SU

LT

ING

EN

GI

NE

ER

S E ng in ee rin g, In c.

R

A

3/14/24

1 1/8" = 1'-0"

DEMOLITION PLAN - ADDITIVE OPTION #1

GENERAL NOTES

E102

ELECTRICAL DEMOLITION

PLAN - ADDITIVE OPTION

#1

CSZ

SB

ESERIES

(ADDITIVE OPTION #1)

E201

GENERAL NOTES

E201

ELECTRICAL REMODEL

PLAN - BASE BID

CSZ

SB

ESERIES

N

AT

IO

N

AL

P

AR

K

SE

R

VI

C

E

W

ES

T

5T H

A

VE

N U

E, AN

C H

O R

AG

E, A K

G O

LD

R

U

SH

M

EC

H

AN

IC

AL

R

EN

O

VA

TI

O

N

3/14/24

M2182

An ch or ag e, A

K

Ph on e (9

) 2

-0

C or po ra te N o.

: A

EC

C

W es t F ire we ed

L an e, S ui te

S

ME

CH

AN

ICA

L A

ND

EL

EC

TR

ICA

L C

ON

SU

LT

ING

EN

GI

NE

ER

S E ng in ee rin g, In c.

R

A

3/14/24

1 REMODEL PLAN - BASE BID

1/8" = 1'-0"

2 ENLARGED POWER PLAN - BASE BID

1/8" = 1'-0"

IO

N

AL

P

AR

K

SE

R

VI

C

E

W

ES

T

5T H

A

VE

N U

E, AN

C H

O R

AG

E, A K

G O

LD

R

U

SH

M

EC

H

AN

IC

AL

R

EN

O

VA

TI

O

N

3/14/24

M2182

An ch or ag e, A

K

Ph on e (9

) 2

-0

C or po ra te N o.

: A

EC

C

W es t F ire we ed

L an e, S ui te

S

ME

CH

AN

ICA

L A

ND

EL

EC

TR

ICA

L C

ON

SU

LT

ING

EN

GI

NE

ER

S E ng in ee rin g, In c.

R

A

3/14/24

1 REMODEL PLAN - ADDITIVE OPTION #1

1/8" = 1'-0"

GENERAL NOTES

E202

ELECTRICAL REMODEL

PLAN - ADDITIVE

OPTION #1

CSZ

SB

ESERIES

(ADDITIVE OPTION #1)

IO

N

AL

P

AR

K

SE

R

VI

C

E

W

ES

T

5T H

A

VE

N U

E, AN

C H

O R

AG

E, A K

G O

LD

R

U

SH

M

EC

H

AN

IC

AL

R

EN

O

VA

TI

O

N

3/14/24

M2182

An ch or ag e, A

K

Ph on e (9

) 2

-0

C or po ra te N o.

: A

EC

C

W es t F ire we ed

L an e, S ui te

S

ME

CH

AN

ICA

L A

ND

EL

EC

TR

ICA

L C

ON

SU

LT

ING

EN

GI

NE

ER

S E ng in ee rin g, In c.

R

A

3/14/24

E301

ELECTRICAL REMODEL

PANEL SCHEDULES

CSZ

SB

M2182 Maintenance Bldg Mseries 100% Signed_3-14-24
M2182 Maintenance Bldg Eseries 100% Signed_3-14-24

File details come from the government source that posted it. Updated .