Attch10_ AF_66 Submittal-FXSB 21-1077 X.xlsx.pdf

PDF 62 KB Posted

Attached to
FXSB 21-1077, Bunkroom Hallway Rpr Federal contract opportunity
Solicitation number
fa500021R0080
Issued by
Department of the Air Force Pacific Air Forces

View the file

Other files for this federal contract opportunity

Other files attached to FXSB 21-1077, Bunkroom Hallway Rpr, newest first.
File Type Posted
Solicitation Amendment_FA500021R00800001 (Summary of Changes).pdf PDF
Attch5_JBER Lock Standards.pdf PDF
Attch11_Q and A.docx DOCX document
Solicitation - FA500021R0080.pdf PDF
Attch3_Drawing Set.pdf PDF
Attch9_Asbestos Abated Areas Test Results.pdf PDF
Attch8_Environmental Protection Specs on JBER (28 Oct 2020 Rev 3).pdf PDF
Attch7_ JBER Telecom Criteria Requirements.pdf PDF
Attch6_Contractors Fire Safety Guide.pdf PDF
Attch2_ Price Schedule.pdf PDF
Attch1_FXSB 21-1077 SOW.pdf PDF
Attch4_Revised JBER CAD.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LI

N

E N

U M

B

ER

C

ER

TI

F.

O F

C O

M

PL

IA

N

C E

SH

O

P D

R

AW

IN

G

S

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

TU

R

U R

'S R

EC

O

M M

EN

D

AT

IO

N

C

AT

AL

O

G D

AT

A

O &M

R

EC

O M

M

EN

D

AT

IO

N

S

C

AL

C U

LA

TI

O N

S

W

AR

R

AN

TY

D R

AW

IN

G S

R

EP

O R

T

TE

ST

R

ES

U

LT

S

R

EQ

U

IR

ED

S

U

BM

IS

SI

O N

D

AT

E

D

AT

E

TO

C O

N

TR

AC

TI

N G

D

AT

E

TO

C

IV

IL

E

N G

IN

EE

R

IN

G

R

ET

U R

N S

U

SP

EN

SE

D

AT

E

SU

BM

IT

TA

L N

U M

BE

R

S

AP

PR

O

VE

D

D

IS

AP

PR

O

VE

D

C O

N

TR

AC

TO

R S

U

BM

IT

TA

L

FI

N

AL

A

PP

R

O

VA

L

GENERAL

Project Specific Form 66 X NTP + 30 Construction Schedule X NTP + 30 TCN Schedule (electronic required, hard copy optional) NTP + 30

Contractor's Health, Safety, and Environment Plan X NTP + 30 Contractor's QA/QC Plan X NTP + 30

DESIGN

All submissions to be provided in hard copy and electronically (The electronic submission will include the *.CTB file and any other supporting file required to print the drawing correctly) 95%, and 100% Design Drawings to include:

X

NTP + 60

(65%) NTP +

75 (95%)

NTP + 90

(100%)

Floor Plan, Elevations, Sections, Schedules, and Details X NTP + 60

Electrical Layout X X NTP + 60

DEMOLITION/ASBESTOES

Demolition Plan X NTP + 60 Asbestoes Plan X NTP + 60

ARCHITECTURAL

Doors and Frames X X X X X Door Hardware X X X X Interior Painting X X Wood Studs X Gypsum Board-Type X X Rubber Cove Base X X Laminate flooring X X Interior Paint X X

ELECTRICAL

Provide electrical one-line dragram X NTP+45 Provide comm's one-line diagram X NTP+45 Cables(electrical,comm,fire alarm) X NTP+45 Swtches X NTP+45 Receptacles X NTP+45 Breakers X NTP+45 Conduits X NTP+45 Communication System Outlets(incl jacks) X NTP+45

CLOSEOUT

As Builts (electronic in AutoCAD 2018 or newer and hard copies) X Final + 7

SCHEDULE OF MATERIAL SUBMITTALS

TO BE COMPLETED BY PROJECT ENGINEER

PROJECT NUMBER PROJECT NAME SOLICITATION /CONTRACT NUMBER

FXSB 21-1077 Repair Bunkroom and Hallways

AF FORM 66, OCT 99 Previous Edition Will Be Used

File details come from the government source that posted it. Updated .