About this file
This document contains architectural drawings for the fit-up of Building 1217 at Joint Base Andrews, MD, under the 668th Alteration & Installations Squadron of the Department of the Air Force's Sixteenth Air Force. The drawings provide details on the construction of perimeter walls, partitions, doors, and other interior features to meet security requirements for a Sensitive Compartmented Information Facility (SCIF).
The related federal contract opportunity is for the installation of an Access Control System (ACS) and Intrusion Detection System (IDS) for the 113th Operations Support Squadron at Building 1217, to be compatible with the existing Honeywell Vindicator security infrastructure. This is a 100% Small Business Set-Aside solicitation under NAICS code 561621 with a $25M size standard. The solicitation number is W50S6W-24-Q-0005, with a response due date of September 20, 2024 and an anticipated award date of September 24, 2024. The contracting office is the 113 MSG/MSC, and the government points of contract are SMSgt Stacey Little and MSgt Bo Im.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| IDS Site Visit Attendance.pdf | ||
| W50S6W-24-Q-0005_113OG_IDS_ SCIF_COMBO Updated 19 September 2024.pdf | ||
| Attch_05_Questions and Answers--B1217 SCIF.pdf | ||
| Attch_01_SOW_B1217 IDS Updated 23 August 2024.pdf | ||
| Final Sole Source-Name Brand Only Determination Under SAT FAR Part 13 Procedures _COMBO.pdf | ||
| Attch_03_ WD-SCA 2015-4281REV30 22 Jul 2024.pdf | ||
| Attch_04_IC-Tech-Specs-for-Const-and-Mgmt-of-SCIFs-v15.pdf | ||
| W50S6W-24-Q-0001_113OG_IDS_ SCIF_COMBO Updated 29 August 2024 (1).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J O
IN
T
B A
S E
S A
N A
N T
O N
IO
-L
A C
K L A
N D
T
X
T
H A
L T
E R
A T
IO
N
I
N S
T A
L L A
T
IO
N S
Q
D E
P A
R T
M E
N T
O F T
H E
A
IR
F O
R C
E
S
IX
T E
E N
T H
A
IR
F O
R C
E S
U B
M
IT
T A
L
O
S S
F A
C
IL
IT
Y
-F
IT
U P
B L D
G
A N
D R
E W
S A
F B
M
D
668-19281-J1
LS-1010 2' 4'0 6'
J O
IN
T
B A
S E
S A
N A
N T
O N
IO
-L
A C
K L A
N D
T
X
T
H A
L T
E R
A T
IO
N
I
N S
T A
L L A
T
IO
N S
Q
D E
P A
R T
M E
N T
O F T
H E
A
IR
F O
R C
E
S
IX
T E
E N
T H
A
IR
F O
R C
E S
U B
M
IT
T A
L
O
S S
F A
C
IL
IT
Y
-F
IT
U P
B L D
G
A N
D R
E W
S A
F B
M
D
668-19281-J1
A-10300 2' 4' 8'
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text O:\16AF_I\70 ISRW\543ISRG\668ALIS\CE\CEPD-DRAFTING\DRAWINGS\PROJECTS\CONUS\ANDREWS\BOB\668-19281-J1\668-19281-J1 95% JUNE2023.DWG
AutoCAD SHX Text
DRAWING LOCATION:
AutoCAD SHX Text
PLOT DATE:
AutoCAD SHX Text 17-Jul-23
AutoCAD SHX Text
PLOT SCALE:
AutoCAD SHX Text
1:1 @ ARCH_D
AutoCAD SHX Text
CUI
AutoCAD SHX Text
CUI
AutoCAD SHX Text
SUBMITTAL DATE:
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text
DRAFTED BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CEN APPROVED
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
SUBMITTAL_DATE
AutoCAD SHX Text
06 DEC 2022
AutoCAD SHX Text
DAG
AutoCAD SHX Text
MJP
AutoCAD SHX Text
JRA
AutoCAD SHX Text
DDF
AutoCAD SHX Text
ARCHITECTURAL FLOOR PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ARCHITECTURAL FLOOR PLAN SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
GRAPHIC SCALE: 1/4" = 1'-0"
AutoCAD SHX Text GENERAL NOTES: 1. CONSTRUCTION OF PERIMETER WALLS SHALL CONFORM TO ICD/ICS 705. ALL OTHER CONSTRUCTION CONSTRUCTION OF PERIMETER WALLS SHALL CONFORM TO ICD/ICS 705. ALL OTHER CONSTRUCTION SHALL CONFORM TO PERTINENT UFC/AFI STANDARDS. 2. CUSTOMER SHALL COORDINATE ACTIVITIES ASSOCIATED WITH REQUIRED INTRUSION DETECTION SYSTEM. CUSTOMER SHALL COORDINATE ACTIVITIES ASSOCIATED WITH REQUIRED INTRUSION DETECTION SYSTEM. 3. ALL EXISTING STRUCTURAL FRAMING AND MASONRY WALLS SHALL REMAIN UNLESS NOTED OTHERWISE. ALL EXISTING STRUCTURAL FRAMING AND MASONRY WALLS SHALL REMAIN UNLESS NOTED OTHERWISE. 4. ALL EXISTING ROOF FRAMING, FLOOR FRAMING, AND COMPOSITE SLAB SHALL REMAIN UNLESS NOTED ALL EXISTING ROOF FRAMING, FLOOR FRAMING, AND COMPOSITE SLAB SHALL REMAIN UNLESS NOTED OTHERWISE. 5. APPLY CONTINUOUS SOUND SEALANT TO ALL PENETRATIONS INTO THE SECURE AREA AND AROUND APPLY CONTINUOUS SOUND SEALANT TO ALL PENETRATIONS INTO THE SECURE AREA AND AROUND ALL PERIMETER WALLS ALONG CORNERS, CONCRETE FLOOR, TRUE CEILING, DOOR FRAMES, WINDOW FILLINGS, ETC. 6. PERIMETER WALLS AND DOORS SHALL BE CONSTRUCTED WITH INDUSTRY STANDARDS TO AN STC PERIMETER WALLS AND DOORS SHALL BE CONSTRUCTED WITH INDUSTRY STANDARDS TO AN STC RATING OF 45. - REFERENCE DETAILS FOR WALL ASSEMBLY. 7. CONFERENCE ROOM WALLS, DOOR, AND CEILING SHALL BE CONSTRUCTED WITH INDUSTRY STANDARDS CONFERENCE ROOM WALLS, DOOR, AND CEILING SHALL BE CONSTRUCTED WITH INDUSTRY STANDARDS TO AN STC RATING OF 50. - REFERENCE DETAILS FOR WALL. 8. FURNISH AND INSTALL COLUMNS, PARTITIONS, AND PONY WALLS - REFERENCE DETAILS FOR FURNISH AND INSTALL COLUMNS, PARTITIONS, AND PONY WALLS - REFERENCE DETAILS FOR ASSEMBLY. 9. INSTALL DOORS, FRAMES, HARDWARE, AND ATTACHEMENTS TO SUBFRAMING -REFERENCE DOOR AND INSTALL DOORS, FRAMES, HARDWARE, AND ATTACHEMENTS TO SUBFRAMING -REFERENCE DOOR AND FRAME SCHEDULE. 10. REFERENCE ROOM FINISH SCHEDULE FOR FINISHES. ALL WALLS SHALL BE UNIFORMLY FINISHED. I.E. REFERENCE ROOM FINISH SCHEDULE FOR FINISHES. ALL WALLS SHALL BE UNIFORMLY FINISHED. I.E. TEXTURED AND PAINT FROM TRUE FLOOR TO TRUE CEILING. 11. PAINT ABOVE DROP CEILING SHALL BE BLACK, TO INCLUDE CMU. PAINT ABOVE DROP CEILING SHALL BE BLACK, TO INCLUDE CMU. 12. ROOM NUMBERS ARE FOR CONSTRUCTION PURPOSES ONLY. BUILDING OWNER IS RESPONSIBLE FOR ROOM NUMBERS ARE FOR CONSTRUCTION PURPOSES ONLY. BUILDING OWNER IS RESPONSIBLE FOR SIGNAGE. 13. COORDINATE ACTIVITIES ASSOCIATED WITH TELECOM, MECHANICAL, AND ELECTRICAL EQUIPMENT.COORDINATE ACTIVITIES ASSOCIATED WITH TELECOM, MECHANICAL, AND ELECTRICAL EQUIPMENT.
AutoCAD SHX Text KEYED NOTES: FILL ALL HOLES/GAPS IN PERIMETER WALLS WITH SOUND ATTENUATED FIRE BATT INSULATION, BATT INSULATION, SOUND SEALANT, AND GYPSUM WALLBOARD WHERE APPLICABLE. PAINT W/ BLACK GLASS SPRAY PAINT FIRST. INSTALL FILLER WALL FOR WINDOW OPENING. SEE DETAIL SHEET A-303. INSTALL FIRE-RATED PLYWOOD, ONE SHEET, 4X8, CENTERED ON THE FACE OF THE WALL. INSTALL BULKHEAD TO EXTEND FROM EXISTING FRAME AND COVER AS NEEDED FOR ELECTRICAL CONDUIT. SOUTH WALL TO MATCH LOCATION OF EXISTING WALL.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RM# 117
AutoCAD SHX Text
RM# 116
AutoCAD SHX Text
RM# 114
AutoCAD SHX Text
RM# 113
AutoCAD SHX Text
RM# 112
AutoCAD SHX Text
RM# 111
AutoCAD SHX Text 111B
AutoCAD SHX Text 111A
AutoCAD SHX Text
RM# 115
AutoCAD SHX Text
RM# 110
AutoCAD SHX Text
435 SQ FT
AutoCAD SHX Text
AutoCAD SHX Text
BLDG KEY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A1
AutoCAD SHX Text A-303
AutoCAD SHX Text A3
AutoCAD SHX Text A-303
AutoCAD SHX Text A2
AutoCAD SHX Text A-303
AutoCAD SHX Text A7
AutoCAD SHX Text A-303
AutoCAD SHX Text A8
AutoCAD SHX Text A-303
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
667 SQ FT
AutoCAD SHX Text
360 SQ FT
AutoCAD SHX Text
100 SQ FT
AutoCAD SHX Text
100 SQ FT
AutoCAD SHX Text
177 SQ FT
AutoCAD SHX Text
148 SQ FT
AutoCAD SHX Text
52 SQ FT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text A-302
AutoCAD SHX Text A3
AutoCAD SHX Text A-303
AutoCAD SHX Text A11
AutoCAD SHX Text A-303
AutoCAD SHX Text A4
AutoCAD SHX Text A-303
AutoCAD SHX Text A6
AutoCAD SHX Text A-303
AutoCAD SHX Text A10
AutoCAD SHX Text A-303
AutoCAD SHX Text
AutoCAD SHX Text A-302
AutoCAD SHX Text
AutoCAD SHX Text A-302
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A9
AutoCAD SHX Text A-303
AutoCAD SHX Text A4
AutoCAD SHX Text A-303
AutoCAD SHX Text A6
AutoCAD SHX Text A-303
AutoCAD SHX Text A1
AutoCAD SHX Text A-303
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A9
AutoCAD SHX Text A-303
AutoCAD SHX Text A6
AutoCAD SHX Text A-303
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A6
AutoCAD SHX Text A-303
AutoCAD SHX Text A4
AutoCAD SHX Text A-303
AutoCAD SHX Text
AutoCAD SHX Text A1
AutoCAD SHX Text A-303
AutoCAD SHX Text A6
AutoCAD SHX Text A-303
AutoCAD SHX Text A5
AutoCAD SHX Text A-303
AutoCAD SHX Text A12
AutoCAD SHX Text A-303
AutoCAD SHX Text A13
AutoCAD SHX Text A-304
File details come from the government source that posted it. Updated .