This Statement of Work details a door and window replacement project for a utility building at the Cape Cod Canal, managed by the U.S. Army Corps of Engineers in Bourne, Massachusetts. The project requires replacing multiple doors and windows across different sides of the building, specifically:
- West side: Replace a double door
- South side: Replace a single door and a window
- East side: Replace two windows
The document includes detailed architectural drawings (Figures 2 and 3) showing existing door and window construction specifications, and multiple photographs (Photos 1-7) documenting the current condition of the doors and windows that need replacement. The technical drawings provide precise measurements and construction details for the new installations, including specifications for concrete lintels, sills, and steel sash components.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment W912WJ25QA087-0001.pdf | ||
| Solicitation - W912WJ25QA087.pdf | ||
| Asbestos Lead PCB Report.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REPLACE DOORS AND WINDOWS OF UTILITY BUILDING
CAPE COD CANAL
U.S. ARMY CORP OF ENGINEERS
BOURNE, MASSACHUSETTS
STATEMENT OF WORK
Figure 1
Figure 1: Shows exterior conditions of the utility building, south and west sides.
Figure 2
Figure 2: Shows existing as-built details of the doors.
Figure 3
Figure 3 Shows existing as-built details of the windows.
Photo 1
Photo 1: Shows existing double door on west side to be replaced.
Photo 2
Photo 2: Shows existing double door on west side to be replaced.
Photos 3 and 4
Photos 3 and 4 Shows existing single door to be replaced.
Photo 5
Photo 5 Shows existing windows on east side to be replaced.
Photo 6
Photo 6 Shows existing windows on east side to be replaced.
Photo 7
Photo 7: Shows the typical existing conditions of two of the three windows to be replaced.