Asbestos Lead PCB Report.pdf

PDF 3 MB Posted

Attached to
Door and Window Replacement, Utility Building, Cape Cod Canal, Bourne, MA
Solicitation number
W912WJ25QA087
Issued by

About this file

This document is a comprehensive hazardous materials sampling report prepared by Environmental Consulting and Management (ECM) for the US Army Corps of Engineers regarding the Railroad Bridge Generator Building located at 90 Main Street in Buzzards Bay, Massachusetts. The report details the results of asbestos, lead paint, and polychlorinated biphenyl (PCB) sampling conducted on various building materials in preparation for upcoming renovations.

Key findings include the detection of asbestos in multiple materials such as window glazing, Transite ceiling panels, interior and exterior door caulking, and window caulking, with percentages ranging from <1% to 15% chrysotile. Lead paint sampling revealed varying concentrations across different surfaces, with the highest levels found on the white/grey door exterior trim (3.285%) and white exterior paint on the generator building (1.043%). PCB testing showed one sample of window glazing contained Aroclor-1254 (0.58 ppm) and Aroclor-1260 (0.43 ppm), while other samples tested negative. The report recommends following specific handling, disposal, and worker protection guidelines from OSHA, Massachusetts Department of Labor Standards, and EPA regulations when managing these hazardous materials during renovation work.

View the file

Other files

File Type Posted
Amendment W912WJ25QA087-0001.pdf PDF
Solicitation - W912WJ25QA087.pdf PDF
Attachments.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Septemeber 29, 2023

US Army Corps of Engineers Attn: Mr. Travis Germano 40 Academy Drive Buzzards Bay, MA 02532

Re: Railroad Bridge Generator Building – Asbestos Bulk, Lead Paint Chip, and PCBs Sampling Report

Mr. Germano:

Enclosed are the analytical results of the suspect asbestos bulk, lead paint chip, and polychlorinated biphenyls (PCBs) samples collected by Environmental Consulting and Management (ECM) from the Railroad Bridge Generator Building located at 90 Main Street, Buzzards Bay, MA. The inspection consisted of collecting suspect hazardous materials that will be impacted during the upcoming renovations.

Asbestos Report:

Suspect materials were analyzed for asbestos content utilizing Polarized Light Microscopy (PLM) in accordance with Environmental Protection Agency (EPA) method 600/R-93/116. In addition to collection, location and quantity of identified asbestos containing materials have also been denoted within this report. Please refer to Attachment 1 for the analytical results and Attachment 2 for the building drawing(s). Below is a chart of the samples collected.

Railroad Bridge Generator Building – Asbestos Bulk Sample Results ID# 23050607 Sample # Material Location Asbestos % Quantity

1A Double Door Window Glazing

Generator Building

<1% Chrysotile ~2 sf

(1 Unit)

2A-C Interior Window Glazing 2% Chrysotile ~4 sf

(2 Units)

3A Insulation

Generator Exhaust Line None Detected –

Sealant None Detected –

4A End Cap On Generator None Detected –

5A Generator Generator None Detected –

6A Transite Ceiling Panel Interior 15% Chrysotile ~700 sf

7A Silicone Caulking Around Louver None Detected –

8A Foam Backer Under Louver Caulking None Detected –

9A-B CMU Mortar Interior & Exterior None Detected –

181 Amaral Street O: 401.438.1360 Riverside, RI 02915 F: 401.438.1316 www.ecmne.com http://www.ecmne.com/

Railroad Bridge Generator Building – Asbestos Bulk Sample Results ID# 23050607 Continued Sample # Material Location Asbestos % Quantity

10A-B Door Caulking Interior & Exterior 3% Chrysotile ~2 sf

(1 Unit)

11A-B Window Caulking Exterior 4% Chrysotile ~2 sf

(2 Units)

12A-B Door Caulking Exterior Double Door 4% Chrysotile ~2 sf

(1 Unit)

13A Caulking Exterior Alum Louver None Detected –

14A Floor Paint Epoxy Floor None Detected –

15A CMU Paint Exterior None Detected --

Asbestos Conclusion:

The interior window glazing, Transite ceiling panels, interior and exterior door caulking, exterior window caulking, and exterior door caulking were found to be positive for asbestos content. The double door window glazing was found to be less than 1% asbestos containing. The Massachusetts Department of Environmental Protection (MassDEP) considers any amount of asbestos within a building material to be an asbestos containing waste material (ACWM). Removal of asbestos containing materials (ACM) and ACWM will require notification and will need to be removed by an accredited Massachusetts asbestos abatement contractor if the material is to be impacted in any way.

All other materials were found to be none detected for asbestos content. Any suspect materials not sampled within this report should be tested before being impacted.

Once abated, a visual inspection and clearance air sampling is required to reoccupy the building. The inspection and air sampling must be performed by a Massachusetts licensed Project Monitor and samples must be analyzed by a Massachusetts licensed asbestos air laboratory.

The owner/operator of the facility or facility component shall maintain a copy of the written asbestos sampling report available at the facility for review by or submittal to the MassDEP upon request at all times and shall preserve and maintain such report at the facility for at least two years following the completion of any asbestos abatement activities. If the facility is unstaffed, or in the event that the facility is demolished, the owner/operator shall preserve and maintain the written asbestos survey report at its regular place of business.

Lead Paint Chip Sampling Report:

Paint chip samples were collected from the Railroad Bridge Generator Building to establish the lead concentration of painted surfaces that may be impacted. The lead paint chip samples were analyzed utilizing EPA test method SW846/3050B/7000B. The results can be found in the chart on the following page. Please refer to Attachment 3 for the laboratory results.

181 Amaral Street O: 401.438.1360 Riverside, RI 02915 F: 401.438.1316

Railroad Bridge Generator Building – Lead Paint Chip Sample Results ID# 23050407

Sample ID Material Location Lead Results

(ppm) Lead Results

1 White Paint Generator Building Exterior 10,430 ppm 1.043 %

2 Grey Paint Exterior Alum Lead Bank <87.1 ppm <0.009 %

3 Grey Paint Exterior Fuel Tank <96.1 ppm <0.010 %

4 Grey Epoxy Floor Interior 1,556 ppm 0.156 %

5 Red Paint Interior CMU Wall 4,017 ppm 0.402 %

6 White Paint Interior Wall 317.9 ppm 0.032 %

7 White/Grey Door Exterior Door Trim 32,850 ppm 3.285 %

8 Grey Paint Window Frames 22,020 ppm 2.202 %

9 Black Paint Exterior Electrical Conduit 100.6 ppm 0.010 %

10 Grey Paint Interior Wall/Sill 3,389 ppm 0.339 %

Lead Paint Chip Conclusion:

Including worker protection, disposal, and childhood lead poisoning prevention, several factors may apply when considering a lead hazard.

The State of Massachusetts Childhood Lead Poisoning Prevention Program (CLPPP) and the United States Department of Housing and Urban Development (HUD) considers a dried paint with a lead level of 5,000 parts per million to be lead containing. All surfaces sampled were found to be below the HUD standard. Please follow the recommendations below for handling of these painted items.

ECM recommends utilizing Occupational Safety and Health Administration (OSHA) standards when impacting the lead based paint. OSHA’s lead in construction standard applies to all construction, modification, or repair where workers may be exposed to lead. OSHA's Lead Standard for the Construction Industry, Title 29 Code of Federal Regulations 1926.62, establishes maximum limits of exposure to lead for all workers. The permissible exposure limit (PEL) sets the maximum worker exposure to lead at 50 micrograms per cubic meter (µg/m3) of air averaged over an eight-hour period.

The action level (AL), regardless of respirator use, is an airborne concentration of 30 µg/m3 averaged over an eight-hour period. The AL is the level at which an employer must begin specific compliance activities.

In addition, Per the MA Department of Labor and Standards requires all contractors be licensed as a Lead Safe Renovation Contractor and have at least one certified Lead Safe Renovation Supervisor on the job site at all times when disturbing painted surfaces on pre-1978 housing and child occupied facilities.

Until an exposure assessment is performed, and documentation showing that workers are not exposed above the PEL, OSHA requires that personal protective equipment (PPE) must be utilized.

Prior to disposal, construction waste suspected to contain lead must undergo Toxic Characteristic Leaching Procedure (TCLP) sampling for lead. The EPA specifies that waste containing greater than

5.0 mg/l of lead be disposed of as lead waste.

181 Amaral Street O: 401.438.1360 Riverside, RI 02915 F: 401.438.1316

PCB Report :

ECM collected suspect PCB materials that may require special handling/disposal. The samples were analyzed utilizing EPA method 8082A. The chart below represents the PCB samples collected from the Railroad Bridge Generator Building. Analytical results can be found in Attachment 4.

Railroad Bridge Generator Building – PCB Sample Results WO# 3I11024

Sample ID Description Compound Result

(1 ug/kg = 0.001 ppm)

1 Window Glazing Aroclor-1254 580 ug/kg = 0.58 ppm

Aroclor-1260 434 ug/kg = 0.43 ppm

2 Window Caulking – None Detected

3 Door Caulking – None Detected

PCB Conclusion:

Materials less than 50 ppm are determined to be non-PCB waste in accordance with 40 CFR 761.3.

Sample 1 was found to be 1.1 ppm, and Samples 2 and 3 were found to none detected.

When dealing with PCB waste, site preparation and controls should established and implemented within a work plan prior to removal activities. Removal activities will need to be conducted under a performance-based disposal plan in accordance with 40 CFR 761.62(a). Performance based PCB removal may not require EPA notification.

Limitations:

Environmental Consulting and Management cannot be held responsible for the identification of materials that are hidden, concealed or otherwise inaccessible. Components that could affect building operation and endanger the safety of the inspector such as active mechanical or electrical systems were not scrutinized during this inspection unless otherwise noted. Any suspect materials not sampled and tested for the presence of asbestos must be handled and disposed of as if it were unless analytical data can prove otherwise.

This report was prepared under the request of US Army Corps of Engineers. This report should not be represented, reproduced, or disseminated without the written approval of Environmental Consulting and Management or US Army Corps of Engineers. No warranties other than those stated in the contract for this project are expressed or implied.

A hard copy of this report can be provided for your records via mail upon request. If you have any further questions please contact Daniel Simas at 401-304-6612.

Sincerely, Environmental Consulting & Management

Charles E. Prescott III Project Manager

181 Amaral Street O: 401.438.1360 Riverside, RI 02915 F: 401.438.1316

Attachment 1 Asbestos Bulk Sample Results

181 Amaral Street O: 401.438.1360 Riverside, RI 02915 F: 401.438.1316

SanAir ID#: 23050607

Project #: 230551 Project Name: Railroad Bridge Gen Bldg Report Date: 9/26/2023

Analysis Report prepared for Environmental Consulting & Management Inc

Dear Daniel J. Simas, We at SanAir would like to thank you for the work you recently submitted. The 21 sample(s) were received on Tuesday, September 12, 2023 via UPS. The final report(s) is enclosed for the following sample(s): 1A, 2A, 2B, 2C, 3A, 4A, 5A, 6A, 7A, 8A, 9A, 9B, 10A, 10B, 11A, 11B, 12A, 12B, 13A, 14A, 15A.

These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information

Sample conditions:

- 21 samples in Good condition.

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

230551Project Number:

Army Corp Of Eng Buzzard BayP.O. Number:

Project Name: Railroad Bridge Gen Bldg

9/7/2023Collected Date:

9/12/2023 10:50:00 AMReceived Date:

9/26/2023 9:55:32 AM

23050607 SanAir ID Number

FINAL REPORT

Environmental Consulting & Management IncName:

Address: 50 Kickemuit Ave

Bristol, RI 02809

401-438-1360Phone:

Analyst: Magalis, Lane

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 1A / 23050607-001 Double Door Window Glazing

White Non-Fibrous

Homogeneous

100% Other < 1% Chrysotile

2A / 23050607-002 Int Window Glazing

Grey Non-Fibrous

Homogeneous

98% Other 2% Chrysotile

2B / 23050607-003 Int Window Glazing

Not Analyzed

2C / 23050607-004 Ext Window Glazing

Not Analyzed

3A / 23050607-005 Generator Exhaust Line, Insulation

Grey Non-Fibrous

Heterogeneous

15% Glass 85% Other None Detected

3A / 23050607-005 Generator Exhaust Line, Sealant

White Non-Fibrous

Heterogeneous

30% Glass 70% Other None Detected

4A / 23050607-006 Generator End Cap

Grey Non-Fibrous

Heterogeneous

15% Glass 85% Other None Detected

5A / 23050607-007 Generator

Grey Non-Fibrous

Heterogeneous

15% Glass 85% Other None Detected

6A / 23050607-008 Transite Ceiling Panel

White Non-Fibrous

Heterogeneous

85% Other 15% Chrysotile

7A / 23050607-009 Silicon Caulking Around Louver

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 9/26/2023 Date: 9/26/2023

Approved Signatory:

230551Project Number:

Army Corp Of Eng Buzzard BayP.O. Number:

Project Name: Railroad Bridge Gen Bldg

9/7/2023Collected Date:

9/12/2023 10:50:00 AMReceived Date:

9/26/2023 9:55:32 AM

23050607 SanAir ID Number

FINAL REPORT

Environmental Consulting & Management IncName:

Address: 50 Kickemuit Ave

Bristol, RI 02809

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 8A / 23050607-010 Foam Backer Under 7A

White Non-Fibrous

Homogeneous

100% Other None Detected

9A / 23050607-011 CMU Mortar Int

White Non-Fibrous

Heterogeneous

100% Other None Detected

9B / 23050607-012 CMU Mortar Ext

White Non-Fibrous

Heterogeneous

100% Other None Detected

10A / 23050607-013 Int Door Caulking

Tan Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

10B / 23050607-014 Ext Door Caulking

Not Analyzed

11A / 23050607-015 Ext Window Caulking

White Non-Fibrous

Homogeneous

96% Other 4% Chrysotile

11B / 23050607-016 Ext Window Caulking

Not Analyzed

12A / 23050607-017 Ext Double Door Caulking

Various Non-Fibrous

Heterogeneous

96% Other 4% Chrysotile

12B / 23050607-018 Int Double Door Caulking

Not Analyzed

13A / 23050607-019 Ext Alum Louver Caulking

Clear Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 9/26/2023 Date: 9/26/2023

Approved Signatory:

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

230551Project Number:

Army Corp Of Eng Buzzard BayP.O. Number:

Project Name: Railroad Bridge Gen Bldg

9/7/2023Collected Date:

9/12/2023 10:50:00 AMReceived Date:

9/26/2023 9:55:32 AM

23050607 SanAir ID Number

FINAL REPORT

Environmental Consulting & Management IncName:

Address: 50 Kickemuit Ave

Bristol, RI 02809

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 14A / 23050607-020 Epoxy Floor Paint

Grey Non-Fibrous

Homogeneous

100% Other None Detected

15A / 23050607-021 Ext CMU Paint

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 9/26/2023 Date: 9/26/2023

Approved Signatory:

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

230551Project Number:

Army Corp Of Eng Buzzard BayP.O. Number:

Project Name: Railroad Bridge Gen Bldg

9/7/2023Collected Date:

9/12/2023 10:50:00 AMReceived Date:

9/26/2023 9:55:32 AM

23050607 SanAir ID Number

FINAL REPORT

Environmental Consulting & Management IncName:

Address: 50 Kickemuit Ave

Bristol, RI 02809

Disclaimer

This report is the sole property of the client named on the SanAir Technologies Laboratory chain-of-custody (COC). Results in the report are confidential information intended only for the use by the customer listed on the COC. Neither results nor reports will be discussed with or released to any third party without our client's written permission. The final report shall not be reproduced except in full without written approval of the laboratory to assure that parts of the report are not taken out of context. This report and any information contained within shall not be edited, altered, or modified in any way by any persons or agencies receiving, viewing, distributing, or otherwise possessing a copy of this final report. The laboratory reserves the right to perform amendments to any finalized report, of which shall supersede and make obsolete any previous editions. Such changes, modifications, additions, or deletions shall be effective immediately upon notice thereof, which may be given by means including but not limited to posting on the SanAir client portal website, electronic or conventional mail, or by any other means. The information provided in this report applies only to the samples submitted and is relevant only for the date, time, and location of sampling. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client on the COC. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample(s) in the condition in which they arrived at the laboratory and information provided by the client on the COC, such as: project number, project name, collection dates, po number, special instructions, samples collected by, sample numbers, sample identifications, sample type, selected analysis type, flow rate, total volume or area, and start stop times that may affect the validity of the results in this report. Samples were received in good condition unless otherwise noted on the report.

SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. This report does not constitute nor shall not be used by the client to claim product, process, system, or person certification, approval, or endorsement by NVLAP, NIST, NELAC, AIHA LAP, LLC or any other U.S. governmental agencies and may not be accredited by every local, state, and federal regulatory agencies. Samples are held for a period of 60 days. Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. For NY state samples, method EPA 600/M4-82-020 is performed.

NYELAP Disclaimer:

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

Asbestos Accreditations National Voluntary Laboratory Accreditation Program (NVLAP) Lab Code 200870-0 City of Philadelphia Department of Public Health Air Management Services, Certification#ALL-460 Commonwealth of Pennsylvania Department of Environmental Protection Number 68-05397 California State Environmental Laboratory Accreditation Program Certificate Number 2915 Colorado Department of Public Health and Environment Registration Number AL-23143 Connecticut Department of Public Health Environmental Laboratory Registration Number PH-0105 Massachusetts Department of Labor Standards Asbestos Analytical Services License Number:

AA000222

State of Maine Department of Environmental Protection License Number: LB-0075, LA-0084 New York State Department of Health Laboratory ID: 11983 State of Rhode Island Department of Health Certification No.: PCM00126, PLM00126, TEM00126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia Department of Professional and Occupational Regulation Number:

3333000323 State of Washington Department of Ecology Laboratory ID: C989 State of West Virginia Bureau for Public Health Analytical Laboratory Number: LT000616 Vermont Department of Health License Number: Asb-Co-An-000006 Louisiana Department of Environmental Quality AI Number 212253, Certificate #05088

Revision Date: 4/18/2023 Page 6 of 8

Attachment 2 Building Photos

181 Amaral Street O: 401.438.1360 Riverside, RI 02915 F: 401.438.1316

181 Amaral Street O: 401.438.1360 Riverside, RI 02915 F: 401.438.1316

181 Amaral Street O: 401.438.1360 Riverside, RI 02915 F: 401.438.1316

Attachment 3 Lead Paint Chip Sample Results

181 Amaral Street O: 401.438.1360 Riverside, RI 02915 F: 401.438.1316

SanAir ID#: 23050407

Project #: 230551 Project Name: Railroad Bridge - Gen Bldg Report Date: 9/19/2023

Analysis Report prepared for Environmental Consulting & Management Inc

Dear Daniel Simas, We at SanAir would like to thank you for the work you recently submitted. The 10 sample(s) were received on Tuesday, September 12, 2023 via UPS. The final report(s) is enclosed for the following sample(s): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10.

These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Abisola Kasali Metals Laboratory Director SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis on Test Family AA

- Disclaimers and Additional Information

Sample conditions:

- 10 samples in Good condition.

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

230551Project Number:

Army Corp Of EngP.O. Number:

Project Name: Railroad Bridge - Gen Bldg

9/7/2023Collected Date:

9/12/2023 10:50:00 AMReceived Date:

9/19/2023 9:29:48 AM

23050407 SanAir ID Number

FINAL REPORT

Environmental Consulting & Management IncName:

Address: 50 Kickemuit Ave

Bristol, RI 02809

Analyst: Rivera, Shirley

Test Method: SW846/M3050B/7000B

Lead Paint Analysis PAINT µg Pb Sample Size Calculated Sample Sample

Sample Description In Sample (grams) RL Results Results

23050407 - 1 1 1283 0.123 81.3 10430 1.043 % White Ext Paint On Generator Bldg µg/g (ppm) By Weight

23050407 - 2 2 < 10 0.1148 87.1 <87.1 <0.009 % Grey Paint On Alum Ext Lead Bank µg/g (ppm) By Weight

23050407 - 3 3 < 10 0.1041 96.1 <96.1 <0.010 % Grey Paint On Fuel Tank (Outside) µg/g (ppm) By Weight

23050407 - 4 4 157 0.1007 99.3 1556 0.156 % Grey Epoxy Floor µg/g (ppm) By Weight

23050407 - 5 5 431 0.1072 93.3 4017 0.402 % Red Paint On Int CMU Wall (Fire Extinguisher Loc) µg/g (ppm) By Weight

23050407 - 6 6 33 0.1037 96.4 317.9 0.032 % White Interior Wall Paint µg/g (ppm) By Weight

23050407 - 7 7 3565 0.1085 92.2 32850 3.285 % White/Grey Door Ext Trim µg/g (ppm) By Weight

23050407 - 8 8 2319 0.1053 95 22020 2.202 % Grey Paint On Window Frames µg/g (ppm) By Weight

23050407 - 9 9 12 0.1155 86.6 100.6 0.010 % Black Paint On Ext Elec Conduit µg/g (ppm) By Weight

23050407 - 10 10 350 0.1033 96.8 3389 0.339 % Grey Paint On Int Wall/Sill µg/g (ppm) By Weight

Method Reporting Limit <10 µg/0.1 g paint

Signature:

Date: 9/13/2023 Date: 9/13/2023

Reviewed:

230551Project Number:

Army Corp Of EngP.O. Number:

Project Name: Railroad Bridge - Gen Bldg

9/7/2023Collected Date:

9/12/2023 10:50:00 AMReceived Date:

9/19/2023 9:29:48 AM

23050407 SanAir ID Number

FINAL REPORT

Environmental Consulting & Management IncName:

Address: 50 Kickemuit Ave

Bristol, RI 02809

Disclaimer

SanAir Technologies Laboratory, Inc. participates in the Environmental Lead Accreditation Program (ELAP) administered by AIHA LAP, LLC (Laboratory ID LAP-162952). Refer to our accreditation certificate and scope on our website or www.aihaaccreditedlabs.org for an up to date list of the Fields of Testing for which we are accredited.

SanAir also participates in the State of New York’s DOH-ELAP (Lab Id 11983), and has met the EPA's NLLAP program standards. This report does not constitute nor shall be used by the client to claim product, process, system, or person certification, approval, or endorsement by AIHA LAP, LLC, NELAC, NIST, and/or any other U.S.

governmental agencies; and test results in this report may not be accredited by every local, state or federal regulatory agency.

This report is the sole property of the client named on the SanAir Technologies Laboratory chain-of-custody (COC).

Results in the report are confidential information intended only for the use by the customer listed on the chain of custody. Neither results nor reports will be discussed with or released to any third party without our client’s written permission. Final reports cannot be reproduced, except in full, without written authorization from SanAir

Technologies Laboratory, Inc. This report and any information contained within shall not be edited, altered, or modified in any way by any persons or agencies receiving, viewing, distributing, or otherwise possessing a copy of this final report. The laboratory reserves the right to perform amendments to any finalized report, of which shall supersede and make obsolete any previous editions. Such changes, modifications, additions, or deletions shall be effective immediately upon notice thereof, which may be given by means including but not limited to posting on the SanAir client portal website, electronic or conventional mail, or by any other means. The information provided in this report applies only to the samples submitted and is relevant only for the date, time, and location of sampling. The accuracy of the results of the analysis is dependent upon the method of sample procurement and information provided by the client on the COC. SanAir is not responsible for the method of sample procurement. SanAir assumes no responsibility for information provided by the client on the COC such as project number, project name, collection dates, po number, special instructions, samples collected by, sample numbers, sample identifications, sample type, selected analysis type, flow rate, total volume or area, and start stop times that may affect the validity of the results in this report. SanAir Technologies Laboratory, Inc only assures the precision and accuracy of the data it generates and assumes no responsibility for errors or biasing that occur during collection prior to SanAir’s receipt of the sample(s).

Evaluation reports are based solely on the sample(s) in the condition in which they arrived at the laboratory and on the information provided by the client on the COC. Sample(s) were received in good condition unless otherwise noted on the report. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. SanAir’s Method Detection Limits (MDL) and Reporting Limits (RL) have been derived using various materials meeting each accrediting agencies’ standards. All quality control results are acceptable unless otherwise noted. SanAir does not make contamination corrections to reports based upon analysis of laboratory and/or field blanks. All samples are disposed of after 90 days unless otherwise requested by the client. For Lead Exposure

Limits, refer to HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards and State and Federal

Regulations, where applicable. For Lead Exposure Limits in Air, refer to EPA National Ambient Air Quality Standards, OSHA Action Levels & Permissible Exposure Limits (General Industry & Construction), and relative state or federal requirements where applicable.

AIHA LAP, LLC Lab ID: LAP-162952 Commonwealth of VA Department of General Services DCLS, VELAP Laboratory ID#460251 New York State Department of Health Laboratory ID No: 11983 California State Environmental Laboratory Accreditation Program Certificate No: 2915 State of Connecticut Department of Public Health Environmental Laboratory Registration Number: PH-0105 New Jersey Department of Environment Protection Environmental Laboratory Certification ID# VA014 Ohio Department of Health Environmental Lead Laboratory Approval Number E10049 State of Rhode Island Department of Health Environmental Lead Laboratory No LAO00371

Revision Date 4/18/2023

Attachment 4 PCBs Sample Results

181 Amaral Street O: 401.438.1360 Riverside, RI 02915 F: 401.438.1316

[TOC_1]Cover Letter[

New England Testing Laboratory, Inc.

(401) 353-3420

REPORT OF ANALYTICAL RESULTS

NETLAB Work Order Number: 3I11024

Client Project: 230551 - US Army, Buzzard's Bay

Report Date: 18-September-2023

Richard Warila, Laboratory Director

New England Testing Laboratory, Inc.

59 Greenhill Street

West Warwick, RI 02893 rich.warila@newenglandtesting.com

Dan Simas

Environmental Consulting & Management

81 Amaral Street

Riverside, RI 02915

Prepared for:

NETLAB Case Number: 3I11024

Sample Lab ID Matrix Date Sampled Date Received

Samples Submitted :

The samples listed below were submitted to New England Testing Laboratory on 09/11/23. The group of samples appearing in this report was assigned an internal identification number (case number) for laboratory information management purposes. The client�s designations for the individual samples, along with our case numbers, are used to identify the samples in this report. This report of analytical results pertains only to the sample(s) provided to us by the client which are indicated on the custody record. The case number for this sample submission is 3I11024. Custody records are included in this report.

PCB 1 - Window Glazing Solid (Misc)3I11024-01 09/11/202309/07/2023

PCB 2 - Window Caulking Solid (Misc)3I11024-02 09/11/202309/07/2023

PCB 3 - Door Caulking Solid (Misc)3I11024-03 09/11/202309/07/2023

Request for Analysis

At the client's request, the analyses presented in the following table were performed on the samples submitted.

Analysis Method

PCB 1 - Window Glazing (Lab Number: 3I11024-01)

EPA 8082APCBs (Soxhlet)

Analysis Method

PCB 2 - Window Caulking (Lab Number: 3I11024-02)

EPA 8082APCBs (Soxhlet)

Analysis Method

PCB 3 - Door Caulking (Lab Number: 3I11024-03)

EPA 8082APCBs (Soxhlet)

Method References

Test Methods for Evaluating Solid Waste, Physical/Chemical Methods, SW846, USEPA

Case Narrative

Sample Receipt:

The samples associated with this work order were received in appropriately cooled and preserved containers. The chain of custody was adequately completed and corresponded to the samples submitted.

Exceptions: None

Analysis:

All samples were prepared and analyzed within method specified holding times and according to NETLAB�s documented standard operating procedures. The results for the associated calibration, method blank and laboratory control sample (LCS) were within method specified quality control requirements and allowances. Results for all soil samples, unless otherwise indicated, are reported on a dry weight basis.

Exceptions: None

Results: Polychlorinated Biphenyls (PCBs)

ResultAnalyte

Reporting

Limit Date AnalyzedQual Units

Lab Number: 3I11024-01 (Non-soil solid, as received basis)

Sample: PCB 1 - Window Glazing

Date Prepared

Aroclor-1016 ug/kg 09/14/2309/12/23ND 169

Aroclor-1221 ug/kg 09/14/2309/12/23ND 169

Aroclor-1232 ug/kg 09/14/2309/12/23ND 169

Aroclor-1242 ug/kg 09/14/2309/12/23ND 169

Aroclor-1248 ug/kg 09/14/2309/12/23ND 169

Aroclor-1254 ug/kg 09/14/2309/12/23580 169

Aroclor-1260 ug/kg 09/14/2309/12/23434 169

Aroclor-1262 ug/kg 09/14/2309/12/23ND 169

Aroclor-1268 ug/kg 09/14/2309/12/23ND 169

PCBs (Total) ug/kg 09/14/2309/12/231010 169

Surrogate(s) Recovery% Limits

2,4,5,6-Tetrachloro-m-xylene (TCMX ) 30-10083.7% 09/14/2309/12/23

Decachlorobiphenyl (DCBP) 30-10581.5% 09/14/2309/12/23

ResultAnalyte

Reporting

Limit Date AnalyzedQual Units

Lab Number: 3I11024-02 (Non-soil solid, as received basis)

Sample: PCB 2 - Window Caulking

Date Prepared

Aroclor-1016 ug/kg 09/14/2309/12/23ND 333

Aroclor-1221 ug/kg 09/14/2309/12/23ND 333

Aroclor-1232 ug/kg 09/14/2309/12/23ND 333

Aroclor-1242 ug/kg 09/14/2309/12/23ND 333

Aroclor-1248 ug/kg 09/14/2309/12/23ND 333

Aroclor-1254 ug/kg 09/14/2309/12/23ND 333

Aroclor-1260 ug/kg 09/14/2309/12/23ND 333

Aroclor-1262 ug/kg 09/14/2309/12/23ND 333

Aroclor-1268 ug/kg 09/14/2309/12/23ND 333

PCBs (Total) ug/kg 09/14/2309/12/23ND 333

Surrogate(s) Recovery% Limits

2,4,5,6-Tetrachloro-m-xylene (TCMX ) 30-10076.5% 09/14/2309/12/23

Decachlorobiphenyl (DCBP) 30-10572.7% 09/14/2309/12/23

ResultAnalyte

Reporting

Limit Date AnalyzedQual Units

Lab Number: 3I11024-03 (Non-soil solid, as received basis)

Sample: PCB 3 - Door Caulking

Date Prepared

Aroclor-1016 ug/kg 09/14/2309/12/23ND 172

Aroclor-1221 ug/kg 09/14/2309/12/23ND 172

Aroclor-1232 ug/kg 09/14/2309/12/23ND 172

Aroclor-1242 ug/kg 09/14/2309/12/23ND 172

Aroclor-1248 ug/kg 09/14/2309/12/23ND 172

Aroclor-1254 ug/kg 09/14/2309/12/23ND 172

Aroclor-1260 ug/kg 09/14/2309/12/23ND 172

Aroclor-1262 ug/kg 09/14/2309/12/23ND 172

Aroclor-1268 ug/kg 09/14/2309/12/23ND 172

PCBs (Total) ug/kg 09/14/2309/12/23ND 172

Surrogate(s) Recovery% Limits

2,4,5,6-Tetrachloro-m-xylene (TCMX ) 30-10053.5% 09/14/2309/12/23

Decachlorobiphenyl (DCBP) 30-10599.6% 09/14/2309/12/23

Result

Reporting

Limit Units

Spike

Level

Source

Result %REC

%REC

Limits RPD

RPD

LimitQual Analyte

Quality Control

Polychlorinated Biphenyls (PCBs)

Batch: B3I0410 - 1_Semivolatiles Extractions Prepared: 09/12/23 Analyzed: 09/14/23 Blank (B3I0410-BLK1)

Aroclor-1016 ND 200 ug/kg

Aroclor-1221 ND 200 ug/kg

Aroclor-1232 ND 200 ug/kg

Aroclor-1242 ND 200 ug/kg

Aroclor-1248 ND 200 ug/kg

Aroclor-1254 ND 200 ug/kg

Aroclor-1260 ND 200 ug/kg

Aroclor-1262 ND 200 ug/kg

Aroclor-1268 ND 200 ug/kg

PCBs (Total) ND 200 ug/kg

200 30-100Surrogate: 2,4,5,6-Tetrachloro-m-xylene

(TCMX )

31.262.4 ug/kg

200 30-105Surrogate: Decachlorobiphenyl (DCBP) 54.2108 ug/kg

Prepared: 09/12/23 Analyzed: 09/14/23 LCS (B3I0410-BS1)

Aroclor-1016 941 200 1000 64-11294.1ug/kg

Aroclor-1260 1140 200 1000 59.4-124114ug/kg

200 30-100Surrogate: 2,4,5,6-Tetrachloro-m-xylene

(TCMX )

34.869.5 ug/kg

200 30-105Surrogate: Decachlorobiphenyl (DCBP) 60.8122 ug/kg

Prepared: 09/12/23 Analyzed: 09/14/23 LCS Dup (B3I0410-BSD1)

Aroclor-1016 884 200 1000 2064-11288.4 6.28ug/kg

Aroclor-1260 1090 200 1000 2059.4-124109 4.40ug/kg

200 30-100Surrogate: 2,4,5,6-Tetrachloro-m-xylene

(TCMX )

31.863.5 ug/kg

200 30-105Surrogate: Decachlorobiphenyl (DCBP) 59.3119 ug/kg

Notes and Definitions

Item Definition

Wet Sample results reported on a wet weight basis.

ND Analyte NOT DETECTED at or above the reporting limit.

[TOC_1]Qualifiers and

Definitions[TOC]

9/18/2023

Laboratory Director

MassDEP Analytical Protocol Certification Form

Laboratory Name: New England Testing Laboratory, Inc. Project #: 230551

Project Location: Buzzard¶s Bay RTN:

This Form provides certifications for the following data set: list Laboratory Sample ID Number(s):

3I11024

Matrices: � Groundwater/Surface Water � Soil/Sediment � Drinking Water � Air _ Other: Caulk CAM Protocol (check all that apply below):

8260 VOC

CAM II A �

7470/7471 Hg

CAM III B �

MassDEP VPH

(GC/PID/FID)

CAM IV A �

8082 PCB

CAM V A _

9014 Total Cyanide/PAC

CAM VI A �

6860 Perchlorate

CAM VIII B �

8270 SVOC

CAM II B �

7010 Metals

CAM III C �

MassDEP VPH

(GC/MS)

CAM IV C �

8081 Pesticides

CAM V B �

7196 Hex Cr

CAM VI B �

MassDEP APH

CAM IX A �

6010 Metals

CAM III A �

6020 Metals

CAM III D �

MassDEP EPH

CAM IV B �

8151 Herbicides

CAM V C �

8330 Explosives

CAM VIII A �

TO-15 VOC

CAM IX B �

Affirmative Responses to Questions A through F are UHTXLUHG�IRU�³3Uesumptive &HUWDLQW\´ status

A Were all samples received in a condition consistent with those described on the Chain-of- Custody, properly preserved (including temperature) in the field or laboratory, and prepared/analyzed within method holding times?

_ Yes � No

B Were the analytical method(s) and all associated QC requirements specified in the selected CAM protocol(s) followed?

_ Yes � No

C Were all required corrective actions and analytical response actions specified in the selected CAM protocol(s) implemented for all identified performance standard non-conformances?

_ Yes � No

D Does the laboratory report comply with all the reporting requirements specified in CAM VII A, ³4XDOLW\� $VVXUDQFH� DQG� 4XDOLW\� &RQWURO� *XLGHOLQHV� IRU� WKH� $FTXLVLWLRQ� DQG Reporting of AnalytLFDO�'DWD´"

_ Yes � No

E

VPH, EPH, APH, and TO-15 only

a. VPH, EPH, and APH Methods only: Was each method conducted without significant modification(s)? (Refer to the individual method(s) for a list of significant modifications).

b. APH and TO-15 Methods only: Was the complete analyte list reported for each method?

� Yes � No

� Yes � No

F Were all applicable CAM protocol QC and performance standard non-conformances identified and evaluated in a laboratory narrative (including DOO�³1R´�UHVSRQVHV�Wo Questions A through E)?

_ Yes � No

Responses to Questions G, H and I below are UHTXLUHG�IRU�³3UHVXPSWLYH�&HUWDLQW\´�VWDWXV�

G Were the reporting limits at or below all CAM reporting limits specified in the selected CAM protocol(s)?

_ Yes � No1

Data User Note���'DWD�WKDW�DFKLHYH�³3UHVXPSWLYH�&HUWDLQW\´�VWDWXV�PD\�QRW�QHFHVVDULO\�PHHW�WKH�GDWD�XVDELOLW\�DQG� representativeness requirements described in 310 CMR 40. 1056 (2)(k) and WSC-07-350.

H Were all QC performance standards specified in the CAM protocol(s) achieved? _ Yes � No1

I Were results reported for the complete analyte list specified in the selected CAM protocol(s)? _ Yes � No1 1All negative responses must be addressed in an attached laboratory narrative.

I, the undersigned, attest under the pains and penalties of perjury that, based upon my personal inquiry of those responsible for obtaining the information, the material contained in this analytical report is, to the best of my knowledge and belief, is accurate and complete.

Signature:___________________________________ Position:__________________________

Printed Name:_______________________________ Date:_______________________________ Richard Warila

3H31077 1A_RCRA_Combo_v27_Full FINAL 09 11 23 1122.pdf
Qualifiers and Definitions
Chain of Custody PDF
3I11024 1A_RCRA_Combo_v27_Full FINAL 09 18 23 1317.pdf
Qualifiers and Definitions
Chain of Custody PDF
Work Document PDF

File details come from the government source that posted it. Updated .