This document provides details on a federal solicitation for exhibit fabrication services. The solicitation number 140P2121R0054 was issued by the Department of the Interior National Park Service seeking exhibit fabrication for Hot Springs National Park. Responses are due by the date listed on SAM.gov. Interested parties should review the attached exhibit drawing package for specifications and deliverables required. The opportunity is set aside for small businesses. The final award will be a fixed-price contract for all labor, materials, equipment, and travel necessary to fabricate and install the exhibits defined in the drawings by the required completion date.
View the file
Other files for this federal contract opportunity
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HOT SPRINGS
NATIONAL PARK
Fordyce Bathhouse Exhibits Hot Springs, Arkansas
Exhibit Drawing Package Production Documents II (Revised) November 12, 2016
Attachment 11 HOSP Exhibit Fabrication
Element Identification # Type Case Width Case Depth Case Height Conservation Grade Status Vitrine Form Vitrine Material Ancillary Case Equipment Internal Lighting System Notes
CA-01.02-310 Wall-Mounted 7 3/4 5 1/2 7 3/4 Yes 5 Sides Non-glare Acrylic N/A No
CA.01-02-311 Wall-Mounted 7 3/4 5 1/2 7 3/4 Yes 5 Sides Non-glare Acrylic N/A No
CA-01.04-312 Freestanding 34 1/2 25 1/2 22 1/2 Yes 3 Sides Non-glare Acrylic N/A No
CA-02.02-320 Freestanding 46 1/2 16 1/2 25 3/8 Yes 3 Sides Non-glare Acrylic N/A No
CA-02.03-321 Rail Case 53 7 3/8 8 Yes 1 Side Tempered Glass N/A Yes Diode LED DI-12VBL30-80 Tape
Light w/ Chromopath Square Aluminum Channel
CA-03.02-330 Table Case 55 20 18 Yes 4 Sides Non-glare Acrylic N/A No
CA-03.02-331 Pedestal 19 19 62 Yes 4 Sides Non-glare Acrylic N/A No
CA-03.03-332 Table Case 64 16 18 Yes 4 Sides Non-glare Acrylic N/A No
CA-03.05.333 Table Case 64 16 18 Yes 4 Sides Non-glare Acrylic N/A No
CA-03.06-334 Table Case 55 20 18 Yes 4 Sides Non-glare Acrylic N/A No
CA-04.02-340 Freestanding 34 1/2 25 1/2 22 1/2 Yes 3 Sides Non-glare Acrylic N/A No
NPS
Text Box 44'
Existing Fixture
Existing Fixture
Scene 1- Reflected Ceiling Plan
Scale: 1/4" = 1'-0"
Fordyce Bathhouse Exhibits
NOTES:
PULL CONDUIT FROM EXISTING CEILING
FIXTURES TO TRACK LOCATIONS
SCENE 1 ESTIMATED QTY:
- Track:
(44') LSI two-circut track, white, surface mounted.
- Fixtures:
(22) LSI SSL230-00-White
- Lamps:
(22) PAR 30 LEDs Warm White, Narrow Flood, 120Volt.
SCALE OF FEET
Reflected Ceiling Plan: Scene 1
Fordyce Bathhouse Exhibits
Hot Springs National Park, Arkansas
PHASE
POii (Revised)
SCALE
Noted
Note: Sheet is full-size at 11" x 17"
ISSUE DATE
11.12.2016
REVISION DATE
KEY PLAN
1.11
NPS
The contractor shall revise the fabrication drawings to modify the installation of the murals GL-01.05-100 and Gl-02.02-120. The murals shall be modified from applied graphics (wallpaper) to graphic panels supported by a display system in a style with the exhibit’s typical display system. The contractor shall submit proposed modifications to the COR for review and approval prior to implementing changes.
This structure is identified as a mockup in the SOW so that the fabricator can improve the visibility of the topographic model for children and visitors in wheelchairs.
The contractor shall revise the fabrication drawings to modify the installation of the murals GL-01.05-100 and Gl-02.02-120. The murals shall be modified from applied graphics (wallpaper) to graphic panels supported by a display system in a style with the exhibit’s typical display system. The contractor shall submit proposed modifications to the COR for review and approval prior to implementing changes.
41" 38"
37"
18 3/8"
�- - - - - - - - - - -- 63" - - - - - - - - - -- -�
�- - - - - - - - - -- 60" -- - - - - - - - - - -�
� -- - - - - - -- 52 3/4" -- - - - - - - -� Model
□□□oooo□□
Plan - Bathhouse Row Display
Scale A: 3/4" = 1 '-0"
Front Elevation - Bathhouse Row Display
Scale A: 3/4" = 1 '-0"
II
Side Elevation - Bathhouse Row Display
Scale A: 3/4" = 1'-0"
Scale A
SCALE OF FEET
Fordyce Bathhouse Exhibits
29"
2 3
Isometric View Scale: 3/4" = 1 '-0"
PT 02
WD 01
MTL 01
Framing, Typ.
_.--- -- - - - Diode LED Dl-12VBL30-80 Tape Light w/ Chromopath Square Aluminum Channel
;\" tk. Tempered Glass
...,.,,�- �" tk. Aluminum Fascia
,----tt---t------t- Hardwood Blocking, Painted Black r,-- -----1- Desiccant Chamber 1" sq. Steel Angle Frame w/ ro" tk. Steel Skin
Detail Section - Bathhouse Row Case Scale B: 3" = 1'-0"
Scale B
6 3 0 6
SCALE OF INCHES
Details: Scene 2, CG 3
Fordyce Bathhouse Exhibits
Hot Springs National Park, Arkansas
PHASE
PDII (Revised)
SCALE
Noted
Note: Sheet is full-size at 11" x 17"
ISSUE DATE
11.12.2016
REVISION DATE
2.30 and BrightSign Standard I/O Player XD234
NPS
Revise drawing for the addition of the BrightSign XD234.
Interior Case
Dimensions
Height 8"
Width 53"
Depth 7-3/8"
I 73 /8"
I l 8 " j
I I
I
H ,-, 53"
I I I I I I
------- I-------- -----
I I I I
I I I
I--------
,�, I-
E&J JQJ ,0, [�] [!] I�J I�1 I�]
I ( AO-02.03-010)
Attendant Tags
Plan Scale: 1" = 1'-0"
I I
1� � I
( AO-02.03-011)
Alarm Clock
( AO-02.03-012)
Ticket Booklet Maurice
L _J
( AO-02.03-053)
Fordyce Stamp
I I c=i
( AO-02.03-014) ( AO-02.03-068) ( A0-02.03-016) ( AO-02.03-017)
Push Button Ozark Ashtray Paper Cup Inkwell
I
I I I
-= I I I '
L_J mm L _J L _J
I
I
I L-------------------------------------------------�
Elevation Scale: 1" = 1'-0"
Fordyce Bathhouse Exhibits
Section
NOTES:
1. One case with 8 separate viewing windows
2. Artifacts dashed to show them hidden in elevation view
Scale: 1" = 1 '-0" a
SCALE OF FEET
Case Layout: CA-02.02-321
Fordyce Bathhouse Exhibits
Hot Springs National Park, Arkansas
PHASE
POii (Revised)
SCALE
Noted
Note: Sheet is full-size at 11" x 17"
ISSUE DATE
11.12.2016
REVISION DATE
2.41
Please ensure that accessibility guidelines are followed in the revised exhibit drawings. Scene 4 appears to be missing bars for 27" cane detectability along the sides of its reader rails.
| 00_index (1) |
| 01_schedules (1) |
| 0-10 (1) |
| 0-11 (1) |
| 0-20 (1) |
| 0-21 (1) |
| 0-22 (1) |
| 0-23 (1) |
| 0-40 (1) |
| 1-10 (1) |
| 1-11 (1) |
| 1-20 (1) |
| 1-21 (1) |
| 1-22 (1) |
| 1-23 (1) |
| 1-30 (1) |
| 1-30b (1) |
| 1-31a (1) |
| 1-31b (1) |
| 1-32 (1) |
| 1-40 (1) |
| 2-10 (1) |
| 2-11 (1) |
| 2-20 (1) |
| 2-21 (1) |
| 2-22 (1) |
| 2-23 (1) |
| 2-24 (1) |
| 2-30 (1) |
| 2-31 (1) |
| 2-32 (1) |
| 2-40 (1) |
| 2-41 (1) |
| 3-10 (1) |
| 3-11 (1) |
| 3-20 (1) |
| 3-21 (1) |
| 3-22 (1) |
| 3-23 (1) |
| 3-30 (1) |
| 3-31 (1) |
| 3-32 (1) |
| 3-32a (1) |
| 3-32b (1) |
| 3-32c (1) |
| 3-32d (1) |
| 3-32e (1) |
| 3-33 (1) |
| 3-33a (1) |
| 3-34 (1) |
| 3-35 (1) |
| 3-35a (1) |
| 3-40 (1) |
| 3-41 (1) |
| 3-42 (1) |
| 3-43 (1) |
| 4-10 (1) |
| 4-11 (1) |
| 4-20 (1) |
| 4-21 (1) |
| 4-22 (1) |
| 4-23 (1) |
| 4-30a (1) |
| 4-30b (1) |
| 4-30c (1) |
| 4-40 (1) |
File details come from the government source that posted it. Updated .