Attachment No. 02 Plans_Drawings.pdf
PDF 4 MB Posted
- Attached to
- Boiler and Chiller Replacement at Lame Deer, MT
- Solicitation number
- 75H701-20-R-00060
About this file
This solicitation requests proposals for a boiler and chiller replacement project at the Northern Cheyenne Service Unit Health Center in Lame Deer, Montana. The project magnitude is estimated between $500,000 to $1,000,000. The solicitation is a 100% small business set-aside issued by the Indian Health Service Division of Engineering Services in Seattle. The NAICS code is 238220 for plumbing, heating, and air conditioning contractors with a size standard of $16.5 million. Proposals are due by November 12, 2020 at 2:00 PM Mountain Time. A non-mandatory site visit will be held. All questions must be submitted in writing to the contract specialist by October 29.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A00001_Boiler-Chiller Site Visit Agenda and Sign-in.docx | DOCX document | |
| A00001_Pre-Proposal Inquiries.xlsx | XLSX spreadsheet | |
| A00001_Page 108 from NCSU - SOW Boiler-Chiller - FINAL.pdf.docx | DOCX document | |
| Amendment 00001 RFP 75H701-20-R-00060.pdf | ||
| RFP-75H701-20-R-00060.pdf | ||
| Attachment No. 05 Company Specialized Experience Form.docx | DOCX document | |
| Attachment No. 06 Past Performance Questionnaire (PPQ) Form PPQ-0.docx | DOCX document | |
| Attachment No. 04 Self-Performed Calculation Sheet.docx | DOCX document | |
| Attachment No. 01 Scope of Work_Specifications.pdf | ||
| Attachment No. 03 Wage Determination MT20200057 08282020.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INDIAN HEALTH SERVICE
NORTHERN CHEYENNE SERVICE UNIT
BILLINGS AREA INDIAN HEALTH SERVICE
LAME DEER, MONTANA
A P
P R
O V
E D
A R
C H
I T
E C
T U
R A
L M
E C
H A
N I C
A L
E L
E C
T R
I C
A L
P L
U M
B I N
G
R E
V D
A T
E B
Y D
E S
C R
I P
T I O
N
D E
P A
R T
M E
N T
O
F
H
E A
L T
H
A
D
H
U M
A
S
E R
V I C
E S
I N
D I A
N
H
E A
L T
H
S
E R
V I C
E
D I V
I S
I O
N
O
F
E
N G
I N
E E
R I N
G
S
E R
V I C
E S
D A
L L
A S
Y
U
G
R
E E
T
S
U I T
E a l l a s
T e x s
DWN BY
CKD BY
SCALE
DATE
SHEET OF
PROJECT NUMBER
I N D
AI
N
H
EALTH
S
E R
V I C
E
P H
S
A
B
M I T
T A
L
P
A C
K A
G E
B
B
M I T
T A
L
P
A C
K A
G E
I S
S U
R
C
N
S T
R U
C T
I O
N
NCSU
PROJECT LOCATION
BOILER & CHILLER REPLACEMENT DESIGN
ISSUED FOR CONSTRUCTION DECEMBER 13, 2019
02 DM-1 MECHANICAL DEMO PLAN
03 DM-2 MECHANICAL DEMO PLAN
04 M-1 SYMBOL LEGEND & GENERAL PROJECT NOTES
05 M-2 MECHANICAL NEW WORK PLAN
06 M-3 MECHANICAL NEW WORK PLAN
07 M-4 MECHANICAL DETAILS
08 M-5 MECHANICAL EQUIPMENT SCHEDULE
09 P-1 PLUMBING NEW WORK PLAN
INDEX OF DRAWINGS
01 G-1 COVER SHEET
GENERAL MECHANICAL & PLUMBING
ELECTRICAL
SEQ. DRAWING NO. SHEET
SEQ. DRAWING NO. SHEET
Contract No. HHSI102201800008I Task No. 75H70119F30001T
SCALE:
VICINITY MAP
N.T.S.
NORTH
SCALE:
LOCATION MAP
N.T.S.
LAME DEER,
MONTANA
10 DE-1 ELECTRICAL POWER DEMO PLAN
11 DE-2 ELECTRICAL POWER DEMO PLAN
12 E-1 ELECTRICAL SYMBOL LEGEND & GENERAL NOTES
13 E-2 ELECTRICAL POWER NEW WORK PLAN
14 E-3 ELECTRICAL POWER NEW WORK PLAN
15 E-4 ELECTRICAL ONE-LINE DIAGRAM
16 E-5 ELECTRICAL PANEL SCHEDULE
17 ES-1 ELECTRICAL SITE PLAN - NEW WORK PLAN
SEQ. DRAWING NO. SHEET
NORTH
AutoCAD SHX Text G-1
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
N.MUUS
AutoCAD SHX Text
P.SWIDERSKI
AutoCAD SHX Text
NONE
AutoCAD SHX Text
AutoCAD SHX Text
NORTHERN CHEYENNE SERVICE UNIT
AutoCAD SHX Text
BILLINGS AREA INDIAN HEALTH SERVICE
AutoCAD SHX Text
NCSU BOILER & CHILLER REPLACEMENT DESIGN
AutoCAD SHX Text 12-13-2019
AutoCAD SHX Text
HHSI102201800008I
AutoCAD SHX Text
P
P R
O V
E D
A R
C H
I T
E C
T U
R A
L M
E C
H A
N I C
A L
E L
E C
T R
I C
A L
P L
U M
B I N
G
R E
V D
A T
E B
Y D
E S
C R
I P
T I O
N
D E
P A
R T
M E
H
E A
L T
H
A
M
R
V I C
E S
I N
D I A
N
H
E A
L T
H
S
E R
V I C
E
D I V
I S
I O
N
O
F
E
N G
I N
E E
R I N
G
S
E R
V I C
E S
D A
L L
A S
U
R
E E
T
S
U I T
E l l a s
T e x
DWN BY
CKD BY
SCALE
DATE
SHEET OF
PROJECT NUMBER
I N D
AI
N
H
EALTH
S
E R
V I C
E
P H
S
A
B
M I T
T A
L
P
A C
K A
G E
KEY PLAN
N.T.S.
B
B
M I T
T A
L
P
A C
K A
G E
I S
S U
N
S T
R U
C T
I O
N
MECHANICAL ROOM
NORTH
MECHANICAL YARD
AutoCAD SHX Text H
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text
SHOP
AutoCAD SHX Text
AutoCAD SHX Text
MONITOR
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
TELECOM.
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
ROOM #1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text D.9
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text D.9
AutoCAD SHX Text
NORTHERN CHEYENNE SERVICE UNIT
AutoCAD SHX Text
BILLINGS AREA INDIAN HEALTH SERVICE
AutoCAD SHX Text
NCSU BOILER & CHILLER REPLACEMENT DESIGN
AutoCAD SHX Text 12-13-2019
AutoCAD SHX Text
HHSI102201800008I
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text
1. REMOVE EXISTING BOILER & DRAIN LINE. DISCONNECT VENT, LPG LINE, CONTROLS, REMOVE EXISTING BOILER & DRAIN LINE. DISCONNECT VENT, LPG LINE, CONTROLS, HWS/R PIPING. SEE SHEET M-2 FOR NEW WORK. 2. REMOVE BLOWER AND FLOOR SUPPORT COMPLETE. REMOVE BLOWER AND FLOOR SUPPORT COMPLETE. 3. PATCH AND REPAIR CONCRETE FLOOR AT BASE. PATCH AND REPAIR CONCRETE FLOOR AT BASE. 4. REMOVE BOILER CIRCULATOR PUMP LOCATED BELOW ROOF STRUCTURE. REMOVE BOILER CIRCULATOR PUMP LOCATED BELOW ROOF STRUCTURE. 5. REMOVE BOILER CIRCULATOR PUMP LOCATED ON HOUSEKEEPING PAD. REMOVE BOILER CIRCULATOR PUMP LOCATED ON HOUSEKEEPING PAD. 6. REMOVE BASE MOUNTED END SUCTION CHILLED WATER PUMP, INSULATION, SUCTION REMOVE BASE MOUNTED END SUCTION CHILLED WATER PUMP, INSULATION, SUCTION DIFFUSERS, REDUCERS, VIBRATION ISOLATION PADS, AND FLEXIBLE CONNECTORS. DISCONNECT DRAIN LINE AND PRESSURE GAUGE PIPING AT PUMP. 7. DISCONNECT CHEMICAL POT FEEDER AT PUMP. POT FEEDER AND PIPING TO DISCONNECT CHEMICAL POT FEEDER AT PUMP. POT FEEDER AND PIPING TO REMAIN.
AutoCAD SHX Text A. REFER TO SHEET M-1 FOR GENERAL PROJECT NOTES. REFER TO SHEET M-1 FOR GENERAL PROJECT NOTES. B. NEW BUILDING AUTOMATED SYSTEM (BAS) SHALL BE INTEGRATED AND MATCH NEW BUILDING AUTOMATED SYSTEM (BAS) SHALL BE INTEGRATED AND MATCH EXISTING BAS/LOGIC SYSTEM.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
MECHANICAL DEMO PLAN
AutoCAD SHX Text
B.MARTIN
AutoCAD SHX Text
P.SWIDERSKI
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
DM-1
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
REF.
AutoCAD SHX Text
MECHANICAL DEMO PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B-3
AutoCAD SHX Text B-2
AutoCAD SHX Text B-1
NerissaM
PS
P R
O V
E D
A R
C H
I T
E C
T U
R A
L M
E C
H A
N I C
A L
E L
E C
T R
I C
A L
P L
U M
B I N
G
R E
V D
A T
E B
Y D
E S
C R
I P
T I O
N
D E
P A
R T
M E
H
E A
L T
H
A
M
R
V I C
E S
I N
D I A
N
H
E A
L T
H
S
E R
V I C
E
D I V
I S
I O
N
O
F
E
N G
I N
E E
R I N
G
S
E R
V I C
E S
D A
L L
A S
U
R
E E
T
S
U I T
E l l a s
T e x
DWN BY
CKD BY
SCALE
DATE
SHEET OF
PROJECT NUMBER
I N D
AI
N
H
EALTH
S
E R
V I C
E
P H
S
A
B
M I T
T A
L
P
A C
K A
G E
KEY PLAN
N.T.S.
B
B
M I T
T A
L
P
A C
K A
G E
I S
S U
N
S T
R U
C T
I O
N
MECHANICAL ROOM
NORTH
MECHANICAL YARD
UNDERGROUND
AutoCAD SHX Text
EXISTING AIR COOLED PACKAGED CHILLER
AutoCAD SHX Text
(E) CH-1
AutoCAD SHX Text
EXISTING AIR COOLED PACKAGED CHILLER
AutoCAD SHX Text
(E) CH-2
AutoCAD SHX Text
(E) CHWS
AutoCAD SHX Text
(E) CHWR
AutoCAD SHX Text 6"
AutoCAD SHX Text
MECHANICAL YARD
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text D.9
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text D.9
AutoCAD SHX Text
NORTHERN CHEYENNE SERVICE UNIT
AutoCAD SHX Text
BILLINGS AREA INDIAN HEALTH SERVICE
AutoCAD SHX Text
NCSU BOILER & CHILLER REPLACEMENT DESIGN
AutoCAD SHX Text 12-13-2019
AutoCAD SHX Text
HHSI102201800008I
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text
1. REMOVE EXISTING AIR COOLED PACKAGED CHILLER COMPLETE. REMOVE EXISTING AIR COOLED PACKAGED CHILLER COMPLETE. 2. DISCONNECT CONTROLS, CHILLED WATER SUPPLY & RETURN PIPING. SEE SHEET DISCONNECT CONTROLS, CHILLED WATER SUPPLY & RETURN PIPING. SEE SHEET M-3 FOR NEW WORK. 3. ELECTRICAL EQUIPMENT - BACK-UP GENERATOR, ATS, SWITCHGEAR AND ELECTRICAL EQUIPMENT - BACK-UP GENERATOR, ATS, SWITCHGEAR AND TRANSFORMER. REFER TO ELECTRICAL DRAWINGS.
AutoCAD SHX Text A. REFER TO SHEET M-1 FOR GENERAL PROJECT NOTES. REFER TO SHEET M-1 FOR GENERAL PROJECT NOTES. B. NEW BUILDING AUTOMATED SYSTEM (BAS) SHALL BE INTEGRATED AND MATCH NEW BUILDING AUTOMATED SYSTEM (BAS) SHALL BE INTEGRATED AND MATCH EXISTING BAS/LOGIC SYSTEM.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
MECHANICAL DEMO PLAN
AutoCAD SHX Text
DM-2
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
REF.
AutoCAD SHX Text
MECHANICAL DEMO PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
B.MARTIN
AutoCAD SHX Text
P.SWIDERSKI
AutoCAD SHX Text 1/4"=1'-0"
A P
P R
O V
E D
A R
C H
I T
E C
T U
R A
L M
E C
H A
N I C
A L
E L
E C
T R
I C
A L
P L
U M
B I N
G
R E
V D
A T
E B
Y D
E S
C R
I P
T I O
N
D E
P A
R T
M E
H
E A
L T
H
A
M
R
V I C
E S
I N
D I A
N
H
E A
L T
H
S
E R
V I C
E
D I V
I S
I O
N
O
F
E
N G
I N
E E
R I N
G
S
E R
V I C
E S
D A
L L
A S
U
R
E E
T
S
U I T
E l l a s
T e x
DWN BY
CKD BY
SCALE
DATE
SHEET OF
PROJECT NUMBER
I N D
AI
N
H
EALTH
S
E R
V I C
E
P H
S
A
B
M I T
T A
L
P
A C
K A
G E
B
B
M I T
T A
L
P
A C
K A
G E
I S
S U
N
S T
R U
C T
I O
N
AutoCAD SHX Text
SYMBOL LEGEND
AutoCAD SHX Text
GENERAL
AutoCAD SHX Text
KEYED NOTE IDENTIFIER
AutoCAD SHX Text
(SOME SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT)
AutoCAD SHX Text
WORK AND EXISTING
AutoCAD SHX Text
EXISTING EQUIPMENT TO BE REMOVED
AutoCAD SHX Text
POINT OF CONNECTION BETWEEN CURRENT
AutoCAD SHX Text
EXISTING PIPING TO BE REMOVED
AutoCAD SHX Text
POINT OF REMOVAL BETWEEN CURRENT
AutoCAD SHX Text
WORK AND EXISTING
AutoCAD SHX Text
PIPING SYMBOLS
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text T
AutoCAD SHX Text
GF/CI
AutoCAD SHX Text
GOVERNMENT FURNISHED,
AutoCAD SHX Text
HZ
AutoCAD SHX Text
HYD
AutoCAD SHX Text
HERTZ
AutoCAD SHX Text
HYDRANT
AutoCAD SHX Text
GOVERNMENT INSTALLED
AutoCAD SHX Text
CONTRACTOR INSTALLED
AutoCAD SHX Text
GOVERNMENT FURNISHED,
AutoCAD SHX Text
AND AIR CONDITIONING
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
PARTICULATE AIR
AutoCAD SHX Text
HEATING COIL
AutoCAD SHX Text
HORSEPOWER
AutoCAD SHX Text
HUMIDISTAT
AutoCAD SHX Text
HEAD, HUB DRAIN,
AutoCAD SHX Text
HAND-OFF-AUTOMATIC
AutoCAD SHX Text
HEATING, VENTILATING
AutoCAD SHX Text
HIGH EFFICIENCY
AutoCAD SHX Text
HW
AutoCAD SHX Text
HP
AutoCAD SHX Text
HTR
AutoCAD SHX Text
HTG
AutoCAD SHX Text
HOA
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
HSTAT
AutoCAD SHX Text
HC
AutoCAD SHX Text
HEATING
AutoCAD SHX Text
HEATER
AutoCAD SHX Text
GF/GI
AutoCAD SHX Text
HEPA
AutoCAD SHX Text
HD
AutoCAD SHX Text
HT
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
VTR
AutoCAD SHX Text
VD
AutoCAD SHX Text V
AutoCAD SHX Text H
AutoCAD SHX Text
VAV
AutoCAD SHX Text
VEL
AutoCAD SHX Text
VAC
AutoCAD SHX Text
TYP
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text
VOLUME DAMPER
AutoCAD SHX Text
VOLTS
AutoCAD SHX Text
VACUUM
AutoCAD SHX Text
VARIABLE AIR VOLUME
AutoCAD SHX Text V
AutoCAD SHX Text
VELOCITY
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
LABORATORY EXHAUST AIR
AutoCAD SHX Text
KILOWATT HOUR
AutoCAD SHX Text
KILOWATT
AutoCAD SHX Text
INCHES
AutoCAD SHX Text
NUMBER (QUANTITY)
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
NOT APPLICABLE
AutoCAD SHX Text
MIXED AIR
AutoCAD SHX Text
GALLONS PER MINUTE
AutoCAD SHX Text
GALLONS PER HOUR
AutoCAD SHX Text
FUME HOOD
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
DEGREES FAHRENHEIT
AutoCAD SHX Text
FEET PER MINUTE
AutoCAD SHX Text
FLEXIBLE CONNECTOR
AutoCAD SHX Text
GPM
AutoCAD SHX Text
GPH
AutoCAD SHX Text
FLEX
AutoCAD SHX Text
FD
AutoCAD SHX Text
FLEX CONN
AutoCAD SHX Text
FLEXIBLE
AutoCAD SHX Text
FH
AutoCAD SHX Text
EXH
AutoCAD SHX Text
FT
AutoCAD SHX Text
FPM
AutoCAD SHX Text
%%DF
AutoCAD SHX Text
FEET
AutoCAD SHX Text
EXHAUST
AutoCAD SHX Text G
AutoCAD SHX Text
SA
AutoCAD SHX Text
ST PR
AutoCAD SHX Text
RPM
AutoCAD SHX Text
RA
AutoCAD SHX Text F
AutoCAD SHX Text
RLA
AutoCAD SHX Text
QTY
AutoCAD SHX Text
PRV
AutoCAD SHX Text
ELECTRIC-PNEUMATIC
AutoCAD SHX Text
CONTROL SYSTEM
AutoCAD SHX Text
BUILDING MANAGEMENT
AutoCAD SHX Text
BUILDING PRESSURE
AutoCAD SHX Text
CLEANOUT
AutoCAD SHX Text
CONSTANT AIR VOLUME
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
DIRECT EXPANSION
AutoCAD SHX Text
CONTINUATION
AutoCAD SHX Text
EP
AutoCAD SHX Text
CFM
AutoCAD SHX Text
DX
AutoCAD SHX Text
DR
AutoCAD SHX Text
DRAIN
AutoCAD SHX Text
CO
AutoCAD SHX Text
CAM
AutoCAD SHX Text
CONT.
AutoCAD SHX Text
BP
AutoCAD SHX Text
BMCS
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text
PSIG
AutoCAD SHX Text
POR
AutoCAD SHX Text
PCM
AutoCAD SHX Text
POC
AutoCAD SHX Text C
AutoCAD SHX Text
OBD
AutoCAD SHX Text
OA
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NA
AutoCAD SHX Text
BRAKE HORSEPOWER
AutoCAD SHX Text
BTU PER HOUR
AutoCAD SHX Text
BOTTOM OF DUCT
AutoCAD SHX Text
BOTTOM OF PIPE
AutoCAD SHX Text
AIR HANDLING UNIT
AutoCAD SHX Text
ACOUSTIC LINING
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
AIR CONDITIONING
AutoCAD SHX Text
ACCESS DOOR
AutoCAD SHX Text
ABOVE FINISHED GRADE
AutoCAD SHX Text A/C
AutoCAD SHX Text
BOD
AutoCAD SHX Text
BHP
AutoCAD SHX Text
BTUH
AutoCAD SHX Text
BOP
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AFF
AutoCAD SHX Text
AFG
AutoCAD SHX Text
ACS DR
AutoCAD SHX Text
ACOUS LN
AutoCAD SHX Text B
AutoCAD SHX Text
MA
AutoCAD SHX Text
LX
AutoCAD SHX Text
KWH
AutoCAD SHX Text A
AutoCAD SHX Text
KW
AutoCAD SHX Text
IN
AutoCAD SHX Text N
AutoCAD SHX Text
(INCHES OF WATER)
AutoCAD SHX Text
REVOLUTIONS PER MINUTE
AutoCAD SHX Text
STATIC PRESSURE
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
RETURN AIR
AutoCAD SHX Text S
AutoCAD SHX Text Q
AutoCAD SHX Text
PRESSURE REDUCING VALVE
AutoCAD SHX Text
RELIEF AIR
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text R
AutoCAD SHX Text
INCH GAGE
AutoCAD SHX Text
PROGRAMMABLE CONTROL
AutoCAD SHX Text
POINT OF CONNECTION
AutoCAD SHX Text
POUNDS PER SQUARE
AutoCAD SHX Text
POINT OF REMOVAL
AutoCAD SHX Text
FROM EXISTING
AutoCAD SHX Text
TO EXISTING
AutoCAD SHX Text
MODULE
AutoCAD SHX Text P
AutoCAD SHX Text O
AutoCAD SHX Text
OPPOSED BLADE DAMPER
AutoCAD SHX Text
OUTSIDE AIR
AutoCAD SHX Text M
AutoCAD SHX Text L
AutoCAD SHX Text K
AutoCAD SHX Text I
AutoCAD SHX Text
CF/CI
AutoCAD SHX Text
CONTRACTOR FURNISHED,
AutoCAD SHX Text
CONTRACTOR INSTALLED
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
SD
AutoCAD SHX Text
INNER DIAMETER
AutoCAD SHX Text
ID
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
MIN
AutoCAD SHX Text
ON CENTER
AutoCAD SHX Text
OC
AutoCAD SHX Text
OUTSIDE DIAMETER
AutoCAD SHX Text
OD
AutoCAD SHX Text U
AutoCAD SHX Text
UNLESS NOTED OTHERWISE
AutoCAD SHX Text
UNO
AutoCAD SHX Text
TBD
AutoCAD SHX Text
TO BE DETERMINED
AutoCAD SHX Text
PH
AutoCAD SHX Text
MEASURE OF ACIDITY OR
AutoCAD SHX Text
ALKALINITY
AutoCAD SHX Text
GA
AutoCAD SHX Text
GAGE
AutoCAD SHX Text
GALVANIZED
AutoCAD SHX Text
GALV
AutoCAD SHX Text
GLOVEBOX EXHAUST VALVE
AutoCAD SHX Text
GEV
AutoCAD SHX Text
EXHAUST VENT
AutoCAD SHX Text
EXV
AutoCAD SHX Text
NPW
AutoCAD SHX Text
NON-POTABLE WATER
AutoCAD SHX Text
DEMOLISH, DEMOLITION
AutoCAD SHX Text
DEMO
AutoCAD SHX Text
TA
AutoCAD SHX Text
TRANSFER AIR
AutoCAD SHX Text
GL
AutoCAD SHX Text
GLYCOL
AutoCAD SHX Text
CAV
AutoCAD SHX Text
CONTINUOUS AIR MONITORING
AutoCAD SHX Text
3WAY CV
AutoCAD SHX Text
THREE WAY CONTROL VALVE
AutoCAD SHX Text
HEAT DETECTOR
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
SST
AutoCAD SHX Text
CLEANOUT TO GRADE
AutoCAD SHX Text
COTG
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
EF
AutoCAD SHX Text
FLOOR CLEANOUT
AutoCAD SHX Text
FCO
AutoCAD SHX Text
OWNER FURNISHED,
AutoCAD SHX Text
OF/CI
AutoCAD SHX Text
CONTRACTOR INSTALLED
AutoCAD SHX Text
OWNER FURNISHED,
AutoCAD SHX Text
OF/OI
AutoCAD SHX Text
OWNER INSTALLED
AutoCAD SHX Text
VFD
AutoCAD SHX Text
VARIABLE FREQUENCY DRIVE
AutoCAD SHX Text
WCO
AutoCAD SHX Text
WALL CLEANOUT
AutoCAD SHX Text W
AutoCAD SHX Text
COTF
AutoCAD SHX Text
CLEANOUT TO FLOOR
AutoCAD SHX Text
CLEANOUT TO WALL
AutoCAD SHX Text
COTW
AutoCAD SHX Text
1. PROVIDE ALL NECESSARY FITTINGS FOR RISES AND OFFSETS IN PIPING REQUIRED PROVIDE ALL NECESSARY FITTINGS FOR RISES AND OFFSETS IN PIPING REQUIRED FOR PROPER INSTALLATION WHETHER OR NOT SHOWN ON DRAWINGS. 2. PROVIDE ALL EQUIPMENT WITH ALL REQUIRED SERVICE AND OPERATIONAL PROVIDE ALL EQUIPMENT WITH ALL REQUIRED SERVICE AND OPERATIONAL CLEARANCES, INCLUDING ALL REQUIRED CLEARANCES TO COMBUSTIBLES (WHERE APPLICABLE) AND ALL CLEARANCES REQUIRED BY NEC ARTICLE 110. 3. COORDINATE WORK WITH OTHER TRADES TO MINIMIZE CONFLICTS. COORDINATE WORK WITH OTHER TRADES TO MINIMIZE CONFLICTS. 4. MECHANICAL CONTRACTOR SHALL KEEP UPDATED AS-BUILT DRAWINGS ON SITE MECHANICAL CONTRACTOR SHALL KEEP UPDATED AS-BUILT DRAWINGS ON SITE FOR REVIEW DURING CONSTRUCTION. PROVIDE AS-BUILT DRAWINGS TO OWNER AFTER CONSTRUCTION HAS BEEN COMPLETED. 5. ALL PIPE PENETRATIONS THRU FIRE-RATED ASSEMBLIES SHALL BE SLEEVED AND ALL PIPE PENETRATIONS THRU FIRE-RATED ASSEMBLIES SHALL BE SLEEVED AND SEALED WITH CODE-APPROVED FIRE BARRIER MATERIALS. 6. SECURE ALL PIPING TO WALLS FOR A RIGID INSTALLATION WITH UNISTRUT SECURE ALL PIPING TO WALLS FOR A RIGID INSTALLATION WITH UNISTRUT BRACKETS AND GASKETED PIPE CLAMPS. 7. ADVISE OWNER REGARDING DAMAGE TO EXISTING ASPHALT, FLOORS, WALLS AND ADVISE OWNER REGARDING DAMAGE TO EXISTING ASPHALT, FLOORS, WALLS AND CEILINGS NECESSARY TO ACCOMPLISH PROPOSED WORK AND PROPOSE REPAIRS TO RETURN DISTURBED SURFACE TO MATCH EXISTING FINISHES. 8. ALL PIPING SHALL BE CONCEALED WHERE POSSIBLE. ALL EXPOSED PIPING, ALL PIPING SHALL BE CONCEALED WHERE POSSIBLE. ALL EXPOSED PIPING, WHERE CONCEALMENT IS NOT POSSIBLE SHALL BE INSTALLED AND PAINTED AS DIRECTED BY IHS REPRESENTATIVE. 9. ALL BRANCHES SHALL BE VALVED AND ALL VALVES SHALL HAVE UNIONS ALL BRANCHES SHALL BE VALVED AND ALL VALVES SHALL HAVE UNIONS ADJACENT. ACCESS PANELS AND DOORS SHALL BE FURNISHED TO GENERAL CONTRACTOR FOR INSTALLATION AND ACCESS TO VALVES WHERE REQUIRED. LOCATE ADDITIONAL VALVES AS SHOWN ON DRAWINGS. 10. ALL PIPING SHALL PITCH TO DRAIN AND CONTRACTOR SHALL PROVIDE VALVING ALL PIPING SHALL PITCH TO DRAIN AND CONTRACTOR SHALL PROVIDE VALVING FOR SYSTEM DRAINAGE. CONTRACTOR SHALL DELIVER A MARKED-UP SET OF PLANS TO THE OWNER (PRIOR TO FINAL PAYMENT) SHOWING ALL BRANCH VALVES AND ALL DRAINAGE POINTS. 11. CARE SHALL BE TAKEN TO AVOID MECHANICAL DUCTWORK, ELECTRICAL EQUIPMENT CARE SHALL BE TAKEN TO AVOID MECHANICAL DUCTWORK, ELECTRICAL EQUIPMENT AND AIR HANDLING EQUIPMENT ABOVE CEILING. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ROUTING WITH OTHER DISCIPLINES, RELOCATION OF PIPING DUE TO CONFLICTS SHALL BE AT THE EXPENSE OF THIS CONTRACTOR.
AutoCAD SHX Text
GENERAL PROJECT NOTES
AutoCAD SHX Text
PIPING DEMOLITION NOTES
AutoCAD SHX Text A. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING AND FINISHING SURFACES CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING AND FINISHING SURFACES (WALLS, FLOORS, CEILINGS) DAMAGED DURING REMOVAL OF EQUIPMENT AND PIPING TO MATCH EXISTING SURFACES UNLESS REMOVAL OR RENOVATION OF SURFACE IS COVERED UNDER ANOTHER SECTION OF THIS CONTRACT. B. CONTRACTOR SHALL RETURN ALL MECHANICAL EQUIPMENT, PIPING, ETC. TO CONTRACTOR SHALL RETURN ALL MECHANICAL EQUIPMENT, PIPING, ETC. TO OWNER OR FACILITIES MAINTENANCE PERSONNEL. IF OWNER OR FACILITIES MAINTENANCE PERSONNEL DO NOT WANT THESE ITEMS, THEN CONTRACTOR SHALL DISPOSE OF ITEMS PROPERLY. C. EXISTING PIPE ROUTING AND EQUIPMENT LOCATIONS ARE APPROXIMATE ONLY. EXISTING PIPE ROUTING AND EQUIPMENT LOCATIONS ARE APPROXIMATE ONLY. EACH BIDDER SHALL SATISFY THEMSELVES AS TO EXISTING BUILDING CONDITIONS BEFORE SUBMITTING HIS/HER BID. NO ALLOWANCE SHALL BE MADE AFTER CONTRACT IS AWARDED TO ALLOW FOR LACK OF PRE-BID INSPECTION OF BUILDING BY SUCCESSFUL BIDDER. D. COORDINATE WORK WITH OTHER TRADES TO MINIMIZE CONFLICTS AND "DOWN COORDINATE WORK WITH OTHER TRADES TO MINIMIZE CONFLICTS AND "DOWN TIME". E. ALL EQUIPMENT AND PIPING NOT INDICATED TO BE REMOVED WITH HATCHING ALL EQUIPMENT AND PIPING NOT INDICATED TO BE REMOVED WITH HATCHING SHALL REMAIN. F. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO COMMENCEMENT OF FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO COMMENCEMENT OF WORK. SHOULD ANY DISCREPANCIES BE DISCOVERED, VERIFY INTENT WITH THE ENGINEER BEFORE PROCEEDING. G. MAINTAIN ALL MECHANICAL, ELECTRICAL, PLUMBING AND COMMUNICATION SERVICES MAINTAIN ALL MECHANICAL, ELECTRICAL, PLUMBING AND COMMUNICATION SERVICES TO OWNER'S OPERATIONAL AREAS WHILE PERFORMING WORK. PROVIDE ALL BYPASS, CROSS CONNECTS AND/OR TEMPORARY ROUTINGS AND CONNECTIONS AS REQUIRED TO ENSURE FULL OPERATION OF ALL SERVICES TO ALL AREAS NOT UNDER CONSTRUCTION AT NO ADDITIONAL COST.
AutoCAD SHX Text M-1
AutoCAD SHX Text
AutoCAD SHX Text
EQUIPMENT IDENTIFIER
AutoCAD SHX Text
CAP OR PLUG
AutoCAD SHX Text
ELBOW - TURNED UP
AutoCAD SHX Text
ELBOW - TURNED DOWN
AutoCAD SHX Text
FLANGE CONNECTION
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
DIAPHRAGM VALVE
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text
GLOBE VALVE
AutoCAD SHX Text
NEEDLE VALVE
AutoCAD SHX Text
GATE VALVE (0S & Y)
AutoCAD SHX Text
UNION
AutoCAD SHX Text
DIRECTION OF FLOW
AutoCAD SHX Text
TEE - OUTLET UP
AutoCAD SHX Text
TEE - OUTLET DOWN
AutoCAD SHX Text
CIRCUIT SETTER
AutoCAD SHX Text
SOLENOID VALVE
AutoCAD SHX Text
EXPANSION LOOP
AutoCAD SHX Text
STRAINER
AutoCAD SHX Text
PRESSURE REDUCING VALVE
AutoCAD SHX Text
RELIEF OR SAFETY VALVE
AutoCAD SHX Text
THERMOMETER
AutoCAD SHX Text
STRAINER W/BLOW-OFF VALVE
AutoCAD SHX Text
PRESSURE GAUGE
AutoCAD SHX Text
BALANCING VALVE
AutoCAD SHX Text
VALVE IN RISE
AutoCAD SHX Text
GAS PRESSURE REGULATOR
AutoCAD SHX Text
WALL CLEAN OUT
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
DOUBLE CLEAN OUT
AutoCAD SHX Text
TRAP PRIMER
AutoCAD SHX Text
WASHER BOX
AutoCAD SHX Text
XXX-X
AutoCAD SHX Text
BUTTERFLY VALVE
AutoCAD SHX Text
PUMP
AutoCAD SHX Text
BACK WATER VALVE
AutoCAD SHX Text
PITCH PIPING DOWN
AutoCAD SHX Text
DIFFERENTIAL PRESSURE SENSOR
AutoCAD SHX Text
VALVE ACTUATOR
AutoCAD SHX Text
DP
AutoCAD SHX Text
SYMBOL, LEGEND & GENERAL PROJECT NOTES
AutoCAD SHX Text
NORTHERN CHEYENNE SERVICE UNIT
AutoCAD SHX Text
BILLINGS AREA INDIAN HEALTH SERVICE
AutoCAD SHX Text
NCSU BOILER & CHILLER REPLACEMENT DESIGN
AutoCAD SHX Text 12-13-2019
AutoCAD SHX Text
HHSI102201800008I
AutoCAD SHX Text
AutoCAD SHX Text
B.MARTIN
AutoCAD SHX Text
P.SWIDERSKI
AutoCAD SHX Text
NONE
P R
O V
E D
A R
C H
I T
E C
T U
R A
L M
E C
H A
N I C
A L
E L
E C
T R
I C
A L
P L
U M
B I N
G
R E
V D
A T
E B
Y D
E S
C R
I P
T I O
N
D E
P A
R T
M E
H
E A
L T
H
A
M
R
V I C
E S
I N
D I A
N
H
E A
L T
H
S
E R
V I C
E
D I V
I S
I O
N
O
F
E
N G
I N
E E
R I N
G
S
E R
V I C
E S
D A
L L
A S
U
R
E E
T
S
U I T
E l l a s
T e x
DWN BY
CKD BY
SCALE
DATE
SHEET OF
PROJECT NUMBER
I N D
AI
N
H
EALTH
S
E R
V I C
E
P H
S
A
B
M I T
T A
L
P
A C
K A
G E
KEY PLAN
N.T.S.
B
B
M I T
T A
L
P
A C
K A
G E
I S
S U
N
S T
R U
C T
I O
N
MECHANICAL ROOM
SHOP
AutoCAD SHX Text
AutoCAD SHX Text
MONITOR
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
TELECOM.
AutoCAD SHX Text
AutoCAD SHX Text H
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
ELECTRICAL ROOM #1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text D.9
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text D.9
AutoCAD SHX Text
NORTHERN CHEYENNE SERVICE UNIT
AutoCAD SHX Text
BILLINGS AREA INDIAN HEALTH SERVICE
AutoCAD SHX Text
NCSU BOILER & CHILLER REPLACEMENT DESIGN
AutoCAD SHX Text 12-13-2019
AutoCAD SHX Text
HHSI102201800008I
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text
1. PROVIDE AND INSTALL NEW HIGH EFFICIENCY CONDENSING BOILER ON EXISTING PROVIDE AND INSTALL NEW HIGH EFFICIENCY CONDENSING BOILER ON EXISTING HOUSEKEEPING PAD. RECONNECT & PROGRAM CONTROLS TO BAS. 2. EXTEND FLUE FROM NEW BOILER AND CONNECT TO EXISTING TYPE "B" FLUE EXTEND FLUE FROM NEW BOILER AND CONNECT TO EXISTING TYPE "B" FLUE ABOVE. NECESSARY OFFSETS NOT TO EXCEED 45 DEGREES. 3. EXTEND LPG LINE AND CONNECT TO NEW BOILER PER DETAIL. EXTEND LPG LINE AND CONNECT TO NEW BOILER PER DETAIL. 4. EXTEND HEATING WATER SUPPLY & RETURN PIPING TO NEW BOILER AND CONNECT. EXTEND HEATING WATER SUPPLY & RETURN PIPING TO NEW BOILER AND CONNECT. 5. CONNECT 8-INCH AIR INTAKE DUCT TO BOILER. EXTEND DUCT UP TO 12'-0" A.F.F CONNECT 8-INCH AIR INTAKE DUCT TO BOILER. EXTEND DUCT UP TO 12'-0" A.F.F AND TERMINATE AT SOUTH EXTERIOR WALL WITH CAP. 6. CONNECT 12-INCH AIR INTAKE DUCT TO BOILER. EXTEND DUCT UP TO 12'-0" CONNECT 12-INCH AIR INTAKE DUCT TO BOILER. EXTEND DUCT UP TO 12'-0" A.F.F. AND TERMINATE AT SOUTH EXTERIOR WALL WITH CAP. 7. EXISTING ATS CONTROL PANEL ON WALL. EXISTING ATS CONTROL PANEL ON WALL. 8. PROVIDE NEW BOILER CIRCULATOR PUMP AND INSTALL IN HEATING RETURN LINE PROVIDE NEW BOILER CIRCULATOR PUMP AND INSTALL IN HEATING RETURN LINE BELOW ROOF STRUCTURE AT LOCATION OF REMOVED PUMP. 9. PROVIDE NEW BOILER CIRCULATOR PUMP AND INSTALL IN HEATING RETURN LINE PROVIDE NEW BOILER CIRCULATOR PUMP AND INSTALL IN HEATING RETURN LINE LOCATED ON HOUSEKEEPING PAD. 10. EXISTING BAS PANEL AND USER WORKSTATION. EXISTING BAS PANEL AND USER WORKSTATION. 11. PROVIDE NEW BASE MOUNTED END SUCTION CHILLED WATER PUMP, SUCTION PROVIDE NEW BASE MOUNTED END SUCTION CHILLED WATER PUMP, SUCTION DIFFUSER, REDUCERS, VIBRATION ISOLATION BODY GASKET, AND FLEXIBLE PIPE CONNECTORS. RECONNECT DRAIN LINE AND PRESSURE GAUGE PIPING TO NEW PUMP. 12. RECONNECT CHEMICAL POT FEEDER PIPING TO NEW PUMP.RECONNECT CHEMICAL POT FEEDER PIPING TO NEW PUMP.
AutoCAD SHX Text A. REFER TO SHEET M-1 FOR GENERAL PROJECT NOTES. REFER TO SHEET M-1 FOR GENERAL PROJECT NOTES. B. REFER TO SHEET M-4 FOR DETAILS. REFER TO SHEET M-4 FOR DETAILS. C. REFER TO SHEET M-5 FOR SCHEDULES. REFER TO SHEET M-5 FOR SCHEDULES. C. NEW BUILDING AUTOMATED SYSTEM (BAS) SHALL BE INTEGRATED AND MATCH NEW BUILDING AUTOMATED SYSTEM (BAS) SHALL BE INTEGRATED AND MATCH EXISTING BAS/LOGIC SYSTEM. D. PROVIDE PIPING, REDUCERS, AND OFFSETS AS REQUIRED FOR A COMPLETE PROVIDE PIPING, REDUCERS, AND OFFSETS AS REQUIRED FOR A COMPLETE INSTALLATION TO EXISTING PIPING SYSTEMS.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
MECHANICAL NEW WORK PLAN
AutoCAD SHX Text M-2
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
REF.
AutoCAD SHX Text
MECHANICAL NEW WORK PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
B.MARTIN
AutoCAD SHX Text
P.SWIDERSKI
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text B-3
AutoCAD SHX Text B-2
AutoCAD SHX Text B-1
AutoCAD SHX Text
CP-2
AutoCAD SHX Text
CP-3
AutoCAD SHX Text
CP-1
AutoCAD SHX Text P-2
AutoCAD SHX Text P-1
P R
O V
E D
A R
C H
I T
E C
T U
R A
L M
E C
H A
N I C
A L
E L
E C
T R
I C
A L
P L
U M
B I N
G
R E
V D
A T
E B
Y D
E S
C R
I P
T I O
N
D E
P A
R T
M E
H
E A
L T
H
A
M
R
V I C
E S
I N
D I A
N
H
E A
L T
H
S
E R
V I C
E
D I V
I S
I O
N
O
F
E
N G
I N
E E
R I N
G
S
E R
V I C
E S
D A
L L
A S
Y
O U
R
E E
T
S
U I T
E l l a s
T e x
DWN BY
CKD BY
SCALE
DATE
SHEET OF
PROJECT NUMBER
I N D
AI
N
H
EALTH
S
E R
V I C
E
P H
S
A
B
M I T
T A
L
P
A C
K A
G E
KEY PLAN
N.T.S.
B
B
M I T
T A
L
P
A C
K A
G E
I S
S U
N
S T
R U
C T
I O
N
MECHANICAL ROOM
NORTH
MECHANICAL YARD
AutoCAD SHX Text
(E) CHWS
AutoCAD SHX Text
(E) CHWR
AutoCAD SHX Text
MECHANICAL YARD
AutoCAD SHX Text
CH-2
AutoCAD SHX Text
CH-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text D.9
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text D.9
AutoCAD SHX Text
NORTHERN CHEYENNE SERVICE UNIT
AutoCAD SHX Text
BILLINGS AREA INDIAN HEALTH SERVICE
AutoCAD SHX Text
NCSU BOILER & CHILLER REPLACEMENT DESIGN
AutoCAD SHX Text 12-13-2019
AutoCAD SHX Text
HHSI102201800008I
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text
1. PROVIDE NEW AIR COOLED PACKAGED CHILLER. PROVIDE NEW AIR COOLED PACKAGED CHILLER. 2. LOCATION OF CONTROL PANEL. LOCATION OF CONTROL PANEL. 3. EXTEND CHILLED WATER SUPPLY & RETURN LINES AND CONNECT TO NEW CHILLER. EXTEND CHILLED WATER SUPPLY & RETURN LINES AND CONNECT TO NEW CHILLER. PROVIDE ALL APPURTENANCES FOR CONNECTIONS TO NEW UNIT PER MANUFACTURER'S REQUIREMENTS. INSULATE NEW PIPING.
AutoCAD SHX Text A. REFER TO SHEET M-1 FOR GENERAL PROJECT NOTES. REFER TO SHEET M-1 FOR GENERAL PROJECT NOTES. B. REFER TO SHEET M-4 FOR DETAILS. REFER TO SHEET M-4 FOR DETAILS. C. REFER TO SHEET M-5 FOR SCHEDULES. REFER TO SHEET M-5 FOR SCHEDULES. D. NEW BUILDING AUTOMATED SYSTEM (BAS) SHALL BE INTEGRATED AND MATCH NEW BUILDING AUTOMATED SYSTEM (BAS) SHALL BE INTEGRATED AND MATCH EXISTING BAS/LOGIC SYSTEM. E. PROVIDE PIPING, REDUCERS, AND OFFSETS AS REQUIRED FOR A COMPLETE PROVIDE PIPING, REDUCERS, AND OFFSETS AS REQUIRED FOR A COMPLETE INSTALLATION TO EXISTING PIPING SYSTEMS.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
MECHANICAL NEW WORK PLAN
AutoCAD SHX Text M-3
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
REF.
AutoCAD SHX Text
MECHANICAL NEW WORK PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
B.MARTIN
AutoCAD SHX Text
P.SWIDERSKI
AutoCAD SHX Text 1/4"=1'-0"
SCALE:
SCALE:
SCALE:
SCALE:
A P
P R
O V
E D
A R
C H
I T
E C
T U
R A
L M
E C
H A
N I C
A L
E L
E C
T R
I C
A L
P L
U M
B I N
G
R E
V D
A T
E B
Y D
E S
C R
I P
T I O
N
D E
P A
R T
M E
H
E A
L T
H
A
M
R
V I C
E S
I N
D I A
N
H
E A
L T
H
S
E R
V I C
E
D I V
I S
I O
N
O
F
E
N G
I N
E E
R I N
G
S
E R
V I C
E S
D A
L L
A S
U
R
E E
T
S
U I T
E l l a s
T e x
DWN BY
CKD BY
SCALE
DATE
SHEET OF
PROJECT NUMBER
I N D
AI
N
H
EALTH
S
E R
V I C
E
P H
S
A
B
M I T
T A
L
P
A C
K A
G E
B
B
M I T
T A
L
P
A C
K A
G E
I S
S U
N
S T
R U
C T
I O
N
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
5" MIN.
AutoCAD SHX Text M-4
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
BOILER DRAIN DETAIL
AutoCAD SHX Text
BOILER DRAIN
AutoCAD SHX Text
TO FLOOR SINK
AutoCAD SHX Text
TERMINATE WITH AIR GAP
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
PITCH DOWN TOWARD DRAIN
AutoCAD SHX Text
CONDENSATE NEUTRALIZATION KIT
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN
AutoCAD SHX Text M-4
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
HEATING WATER PIPING DIAGRAM
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
HWR
AutoCAD SHX Text
HWS
AutoCAD SHX Text
AHU-2
AutoCAD SHX Text
AHU-4
AutoCAD SHX Text
AHU-3
AutoCAD SHX Text
AHU-5
AutoCAD SHX Text
AHU-6
AutoCAD SHX Text
TYPICAL AIR-HANDLING UNIT
AutoCAD SHX Text
AIR VENT
AutoCAD SHX Text
BALANCE VALVE
AutoCAD SHX Text
TYPICAL FAN COIL UNIT
AutoCAD SHX Text
TYPICAL UNIT HEATER
AutoCAD SHX Text
HWR
AutoCAD SHX Text
HWS
AutoCAD SHX Text
AIR SEPARATOR
AutoCAD SHX Text P-3
AutoCAD SHX Text P-4
AutoCAD SHX Text
EXPANSION TANK
AutoCAD SHX Text B-1
AutoCAD SHX Text B-2
AutoCAD SHX Text B-3
AutoCAD SHX Text
NEW HIGH-EFFICIENCY BOILER. TYPICAL OF (3)
AutoCAD SHX Text M-4
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
CHILLED WATER PIPING DIAGRAM
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
AHU-2
AutoCAD SHX Text
AHU-4
AutoCAD SHX Text
AHU-3
AutoCAD SHX Text
AHU-5
AutoCAD SHX Text
AHU-6
AutoCAD SHX Text
AIR VENT (AT HIGHEST POINT)
AutoCAD SHX Text
BALANCE VALVE
AutoCAD SHX Text
TYPICAL FAN COIL UNIT
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
TYPICAL AIR-HANDLING UNIT
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
AIR SEPARATOR
AutoCAD SHX Text
EXPANSION TANK
AutoCAD SHX Text
CH-1
AutoCAD SHX Text
CH-2
AutoCAD SHX Text
NEW AIR-COOLED CHILLER. TYPICAL OF (2)
AutoCAD SHX Text
CP-1
AutoCAD SHX Text
CP-2
AutoCAD SHX Text
CP-3
AutoCAD SHX Text
NEW BOILER CIRCULATOR PUMP. TYPICAL OF (3)
AutoCAD SHX Text P-1
AutoCAD SHX Text P-2
AutoCAD SHX Text
TO FLOOR DRAIN
AutoCAD SHX Text M-4
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
PUMP AND BASE DETAIL - TYPICAL FOR P-1 AND P-2
AutoCAD SHX Text SUCTION SIDE. EXISTING CHILLED WATER PIPES. REFER TO PLANS FOR PIPE SIZES, TYPICAL.
AutoCAD SHX Text
BUTTERFLY VALVE, TYPICAL
AutoCAD SHX Text
ADJUSTABLE SUPPORT
AutoCAD SHX Text
2-1/2" SUCTION FLANGE
AutoCAD SHX Text
FLANGED CONNECTIONS TYPICAL
AutoCAD SHX Text
DRAIN VALVE, TYPICAL
AutoCAD SHX Text
SUCTION DIFFUSER
AutoCAD SHX Text
DISCHARGE SIDE SEE PLANS FOR PIPE SIZE
AutoCAD SHX Text
VERTICAL NON-SLAM CHECK VALVE
AutoCAD SHX Text
FLEXIBLE CONNECTORS
AutoCAD SHX Text
COMPOUND PRESSURE GAUGE W/GAUGE COCK
AutoCAD SHX Text
REDUCER (AS REQ'D)
AutoCAD SHX Text
GAUGE COCK (TYP.)
AutoCAD SHX Text
2" DISCHARGE FLANGE
AutoCAD SHX Text
MOTOR
AutoCAD SHX Text
EXISTING CONCRETE PAD WITH STEEL REINFORCING
AutoCAD SHX Text
VIBRATION ISOLATION BODY GASKET
AutoCAD SHX Text
ANSI/OSHA COUPLING GUARD
AutoCAD SHX Text
NORTHERN CHEYENNE SERVICE UNIT
AutoCAD SHX Text
BILLINGS AREA INDIAN HEALTH SERVICE
AutoCAD SHX Text
NCSU BOILER & CHILLER REPLACEMENT DESIGN
AutoCAD SHX Text 12-13-2019
AutoCAD SHX Text
HHSI102201800008I
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL DETAILS
AutoCAD SHX Text M-4
AutoCAD SHX Text
AutoCAD SHX Text
B.MARTIN
AutoCAD SHX Text
P.SWIDERSKI
AutoCAD SHX Text
NONE
AIR-COOLED CHILLER SCHEDULE
BOILER SCHEDULE
CIRCULATOR PUMP SCHEDULE
CHILLED WATER PUMP SCHEDULE
A P
P R
O V
E D
A R
C H
I T
E C
T U
R A
L M
E C
H A
N I C
A L
E L
E C
T R
I C
A L
P L
U M
B I N
G
R E
V D
A T
E B
Y D
E S
C R
I P
T I O
N
D E
P A
R T
M E
H
E A
L T
H
A
M
R
V I C
E S
I N
D I A
N
H
E A
L T
H
S
E R
V I C
E
D I V
I S
I O
N
O
F
E
N G
I N
E E
R I N
G
S
E R
V I C
E S
D A
L L
A S
Y
O U
R
E E
T
S
U I T
E l l a s
T e x
DWN BY
CKD BY
SCALE
DATE
SHEET OF
PROJECT NUMBER
I N D
AI
N
H
EALTH
S
E R
V I C
E
P H
S
A
B
M I T
T A
L
P
A C
K A
G E
B
B
M I T
T A
L
P
A C
K A
G E
I S
S U
N
S T
R U
C T
I O
N
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MFR.
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
FAN KW
AutoCAD SHX Text
TOTAL KW
AutoCAD SHX Text
ELECTRICAL (VOLT/PH/HZ)
AutoCAD SHX Text
MCA (AMPS)
AutoCAD SHX Text
MOP (AMPS)
AutoCAD SHX Text
COMPRESSOR DATA
AutoCAD SHX Text
MAX. GPM
AutoCAD SHX Text
REFRIG
AutoCAD SHX Text
MIN IPLV
AutoCAD SHX Text
AMBIENT AIR TEMP. °F
AutoCAD SHX Text
OPERATING WEIGHT (LBS)
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
TONS
AutoCAD SHX Text
KW
AutoCAD SHX Text
VOLT/PH
AutoCAD SHX Text
EWT °F
AutoCAD SHX Text
LWT °F
AutoCAD SHX Text
PRESS. DROP (FT. WC)
AutoCAD SHX Text
CH-1
AutoCAD SHX Text
OUTDOOR AIR COOLED
AutoCAD SHX Text
TRANE
AutoCAD SHX Text
CGAM-100
AutoCAD SHX Text 9.7
AutoCAD SHX Text 113.6
AutoCAD SHX Text
460V/3PH/60
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 103.7
AutoCAD SHX Text 480/3
AutoCAD SHX Text 346.6
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 34.4
AutoCAD SHX Text R-410A
AutoCAD SHX Text 14.4
AutoCAD SHX Text 95.0
AutoCAD SHX Text 6,000
AutoCAD SHX Text OPERATION AT 3,500 FEET ELEVATION. EACH CHILLER IS SIZED TO CARRY APPROXIMATELY 50% OF THE BUILDING LOAD. CHILLERS SHALL OPERATE IN A LEAD/LAG FASHION.
AutoCAD SHX Text
CH-2
AutoCAD SHX Text
OUTDOOR AIR COOLED
AutoCAD SHX Text
TRANE
AutoCAD SHX Text
CGAM-100
AutoCAD SHX Text 9.7
AutoCAD SHX Text 113.6
AutoCAD SHX Text
460V/3PH/60
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 103.7
AutoCAD SHX Text 480/3
AutoCAD SHX Text 346.6
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 34.4
AutoCAD SHX Text R-410A
AutoCAD SHX Text 14.4
AutoCAD SHX Text 95.0
AutoCAD SHX Text 6,000
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL #
AutoCAD SHX Text
S.L INPUT (MBH)
AutoCAD SHX Text
THERMAL EFFICIENCY (%)
AutoCAD SHX Text
WATER °F
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
FLOW (GPM)
AutoCAD SHX Text
POWER VOLTS/PH
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
EWT
AutoCAD SHX Text
LWT
AutoCAD SHX Text B-1
AutoCAD SHX Text
THERMAL SOLUTIONS OR APPROVED EQUAL
AutoCAD SHX Text
AMP-1500
AutoCAD SHX Text 1,500
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HEATING WATER
AutoCAD SHX Text 145.5
AutoCAD SHX Text 115/1
AutoCAD SHX Text
LPG BURNER
AutoCAD SHX Text B-2
AutoCAD SHX Text
THERMAL SOLUTIONS OR APPROVED EQUAL
AutoCAD SHX Text
AMP-1500
AutoCAD SHX Text 1,500
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HEATING WATER
AutoCAD SHX Text 145.5
AutoCAD SHX Text 115/1
AutoCAD SHX Text
LPG BURNER
AutoCAD SHX Text B-3
AutoCAD SHX Text
THERMAL SOLUTIONS OR APPROVED EQUAL
AutoCAD SHX Text
AMP-4000
AutoCAD SHX Text 4,000
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HEATING WATER
AutoCAD SHX Text
AutoCAD SHX Text 480/3
AutoCAD SHX Text
LPG BURNER
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
1. LPG BURNER (4"WC TO 14"WC) LPG BURNER (4"WC TO 14"WC) 2. HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER 3. DIRECT SPARK IGNITION SYSTEM WITH UV SCANNER DIRECT SPARK IGNITION SYSTEM WITH UV SCANNER 4. STAINLESS STEEL PRE-MIX BURNER STAINLESS STEEL PRE-MIX BURNER 5. FULL MODULATION, 5:1 TURNDOWN FULL MODULATION, 5:1 TURNDOWN 6. VARIABLE SPEED COMBUSTION BURNER VARIABLE SPEED COMBUSTION BURNER 7. AIR PROVING SWITCH, WATER FLOW SWITCH AND BLOCKED VENT SWITCH AIR PROVING SWITCH, WATER FLOW SWITCH AND BLOCKED VENT SWITCH 8. 24 VAC BOILER CONTROL 24 VAC BOILER CONTROL 9. AIR VENT VALVE AIR VENT VALVE 10. CONDENSATE TRAP WITH CONDENSATE NEUTRALIZER KIT AND BLOCKED CONDENSATE TRAP WITH CONDENSATE NEUTRALIZER KIT AND BLOCKED CONDENSATE SWITCH 11. AIR VENT VALVE AIR VENT VALVE 12. FLUE GAS TEMPERATURE SENSOR FLUE GAS TEMPERATURE SENSOR 13. SUPPLY AND RETURN WATER TEMPERATURE SENSORS SUPPLY AND RETURN WATER TEMPERATURE SENSORS 14. TEN YEAR LIMITED HEAT EXCHANGER WARRANTY. TEN YEAR LIMITED HEAT EXCHANGER WARRANTY. 15. ASME SECTION IV CERTIFIED PRESSURE VESSEL ASME SECTION IV CERTIFIED PRESSURE VESSEL 16. ASME SAFETY RELIEF VALVE, 50 PSI ASME SAFETY RELIEF VALVE, 50 PSI 17. BACNET COMMUNICATIONS GATEWAY FOR BASBACNET COMMUNICATIONS GATEWAY FOR BAS
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
1. FACTORY INSTALLED FREEZE PROTECTION FACTORY INSTALLED FREEZE PROTECTION 2. FLOW SWITCH FLOW SWITCH 3. FOUR (4) SCROLL COMPRESSORS WITH SIX (6) CONDENSER FANS FOUR (4) SCROLL COMPRESSORS WITH SIX (6) CONDENSER FANS 4. TWO (2) REFRIGERATION CIRCUITS TWO (2) REFRIGERATION CIRCUITS 5. PROVIDE FIVE (5) YEAR WARRANTY PROVIDE FIVE (5) YEAR WARRANTY
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL SIZE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
SYSTEM
AutoCAD SHX Text
FLOWRATE (GPM)
AutoCAD SHX Text
HEAD (FEET WC)
AutoCAD SHX Text
RPM
AutoCAD SHX Text
EFFICIENCY
AutoCAD SHX Text
MOTOR SIZE (HP)
AutoCAD SHX Text
WEIGHT (LBS.)
AutoCAD SHX Text
ELECTRICAL (V/PH/HZ)
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
CP-1
AutoCAD SHX Text
PENTAIR
AutoCAD SHX Text 380-4x4x7B
AutoCAD SHX Text
VERTICAL INLINE
AutoCAD SHX Text
HEATING WATER PRIMARY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 83%
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 208-230/460/3/60
AutoCAD SHX Text PIPE FLANGE SPOOL BASE SUPPORT, FLANGED CONNECTIONS ON SUCTION AND DISCHARGE OF PUMP
AutoCAD SHX Text
CP-2
AutoCAD SHX Text
PENTAIR
AutoCAD SHX Text 380-3x3x7B
AutoCAD SHX Text
VERTICAL INLINE
AutoCAD SHX Text
HEATING WATER PRIMARY
AutoCAD SHX Text 145.5
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 71%
AutoCAD SHX Text 1.5
AutoCAD SHX Text
AutoCAD SHX Text 208-230/460/3/60
AutoCAD SHX Text
FLANGED CONNECTIONS ON SUCTION AND DISCHARGE OF PUMP
AutoCAD SHX Text
CP-3
AutoCAD SHX Text
PENTAIR
AutoCAD SHX Text 380-3x3x7B
AutoCAD SHX Text
VERTICAL INLINE
AutoCAD SHX Text
HEATING WATER PRIMARY
AutoCAD SHX Text 145.5
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 71%
AutoCAD SHX Text 1.5
AutoCAD SHX Text
AutoCAD SHX Text 208-230/460/3/60
AutoCAD SHX Text
FLANGED CONNECTIONS ON SUCTION AND DISCHARGE OF PUMP
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
1. CAST IRON CASING PER ASTM A48 CAST IRON CASING PER ASTM A48 2. BRONZE IMPELLER BRONZE IMPELLER 3. CARBON STEEL SHAFT CARBON STEEL SHAFT 4. BRONZE CASE WEAR RING BRONZE CASE WEAR RING 5. CAST IRON MOTOR BRACKET CAST IRON MOTOR BRACKET 6. MECHANICAL SEAL RATED FOR 225°F MECHANICAL SEAL RATED FOR 225°F 7. BRONZE SLEEVE BRONZE SLEEVE 8. ODP MOTOR ENCLOSED ODP MOTOR ENCLOSED
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL SIZE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
SYSTEM
AutoCAD SHX Text
FLOWRATE (GPM)
AutoCAD SHX Text
HEAD (FEET WC)
AutoCAD SHX Text
RPM
AutoCAD SHX Text
EFFICIENCY
AutoCAD SHX Text
MOTOR SIZE (HP)
AutoCAD SHX Text
WEIGHT (LBS.)
AutoCAD SHX Text
ELECTRICAL (V/PH/HZ)
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text P-1
AutoCAD SHX Text
BELL & GOSSETT
AutoCAD SHX Text
E-1510 2BD
AutoCAD SHX Text
END SUCTION
AutoCAD SHX Text
CHILLED WATER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 75%
AutoCAD SHX Text 7.5
AutoCAD SHX Text
AutoCAD SHX Text 208-230/460/3/60
AutoCAD SHX Text
BASE MOUNTED PUMP
AutoCAD SHX Text P-2
AutoCAD SHX Text
BELL & GOSSETT
AutoCAD SHX Text
E-1510 2BD
AutoCAD SHX Text
END SUCTION
AutoCAD SHX Text
CHILLED WATER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 75%
AutoCAD SHX Text 7.5
AutoCAD SHX Text
AutoCAD SHX Text 208-230/460/3/60
AutoCAD SHX Text
BASE MOUNTED PUMP
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
1. PROVIDE FLANGED SUCTION DIFFUSER MODEL DC-3X. PROVIDE FLANGED SUCTION DIFFUSER MODEL DC-3X. 2. PROVIDE STAINLESS STEEL FLEX CONNECTORS PROVIDE STAINLESS STEEL FLEX CONNECTORS 3. ANSI/OSHA COUPLING GUARD ANSI/OSHA COUPLING GUARD 4. CENTER DROP OUT SPACER COUPLING CENTER DROP OUT SPACER COUPLING 5. FABRICATED HEAVY DUTY BASEPLATE FABRICATED HEAVY DUTY BASEPLATE 6. INTERNALLY SELF-FLUSHING MECHANICAL SEAL INTERNALLY SELF-FLUSHING MECHANICAL SEAL 7. ASTM 108 GRADE 1144 SHAFT ASTM 108 GRADE 1144 SHAFT 8. 304 STAINLESS STEEL IMPELLER AND SHAFT SLEEVE 304 STAINLESS STEEL IMPELLER AND SHAFT SLEEVE 9. CAST IRON VOLUTE CAST IRON VOLUTE 10. 175 PSI MAX. WORKING PRESSURE175 PSI MAX. WORKING PRESSURE
AutoCAD SHX Text
NORTHERN CHEYENNE SERVICE UNIT
AutoCAD SHX Text
BILLINGS AREA INDIAN HEALTH SERVICE
AutoCAD SHX Text
NCSU BOILER & CHILLER REPLACEMENT DESIGN
AutoCAD SHX Text 12-13-2019
AutoCAD SHX Text
HHSI102201800008I
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL EQUIPMENT SCHEDULE
AutoCAD SHX Text
B.MARTIN
AutoCAD SHX Text
P.SWIDERSKI
AutoCAD SHX Text
NONE
AutoCAD SHX Text M-5
AutoCAD SHX Text
P R
O V
E D
A R
C H
I T
E C
T U
R A
L M
E C
H A
N I C
A L
E L
E C
T R
I C
A L
P L
U M
B I N
G
R E
V D
A T
E B
Y D
E S
C R
I P
T I O
N
D E
P A
R T
M E
H
E A
L T
H
A
M
R
V I C
E S
I N
D I A
N
H
E A
L T
H
S
E R
V I C
E
D I V
I S
I O
N
O
F
E
N G
I N
E E
R I N
G
S
E R
V I C
E S
D A
L L
A S
Y
O U
R
E E
T
S
U I T
E l l a s
T e x
DWN BY
CKD BY
SCALE
DATE
SHEET OF
PROJECT NUMBER
I N D
AI
N
H
EALTH
S
E R
V I C
E
P H
S
A
B
M I T
T A
L
P
A C
K A
G E
KEY PLAN
N.T.S.
B
B
M I T
T A
L
P
A C
K A
G E
I S
S U
N
S T
R U
C T
I O
N
MECHANICAL ROOM
MONITOR
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
TELECOM.
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE #1
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
LPG
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
MECHANICAL YARD
AutoCAD SHX Text
ELECTRICAL ROOM #1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text D.9
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text D.9
AutoCAD SHX Text
NORTHERN CHEYENNE SERVICE UNIT
AutoCAD SHX Text
BILLINGS AREA INDIAN HEALTH SERVICE
AutoCAD SHX Text
NCSU BOILER & CHILLER REPLACEMENT DESIGN
AutoCAD SHX Text 12-13-2019
AutoCAD SHX Text
HHSI102201800008I
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text
1. INSTALL CONDENSATE NEUTRALIZER ON FINISHED FLOOR. CONNECT 3/4" DRAIN LINE INSTALL CONDENSATE NEUTRALIZER ON FINISHED FLOOR. CONNECT 3/4" DRAIN LINE TO BOILER CONDENSATE TRAP. 2. EXTEND 3/4" CONDENSATE DRAIN LINE FROM NEUTRALIZER KIT TO FLOOR SINK EXTEND 3/4" CONDENSATE DRAIN LINE FROM NEUTRALIZER KIT TO FLOOR SINK AND TERMINATE WITH AIR GAP. 3. CONNECT TO EXISTING OVERHEAD LPG MAIN LINE AND EXTEND 1-1/2" LPG LINE CONNECT TO EXISTING OVERHEAD LPG MAIN LINE AND EXTEND 1-1/2" LPG LINE TO NEW BOILER. 4. CONNECT TO EXISTING OVERHEAD LPG MAIN LINE AND EXTEND 2" LPG LINE TO CONNECT TO EXISTING OVERHEAD LPG MAIN LINE AND EXTEND 2" LPG LINE TO NEW BOILER.
AutoCAD SHX Text A. REFER TO SHEET M-1 FOR GENERAL PROJECT NOTES. REFER TO SHEET M-1 FOR GENERAL PROJECT NOTES. B. NEW BUILDING AUTOMATED SYSTEM (BAS) SHALL BE INTEGRATED AND MATCH NEW BUILDING AUTOMATED SYSTEM (BAS) SHALL BE INTEGRATED AND MATCH EXISTING BAS/LOGIC SYSTEM.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
PLUMBING NEW WORK PLAN
AutoCAD SHX Text P-1
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
REF.
AutoCAD SHX Text
PLUMBING NEW WORK PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
B.MARTIN
AutoCAD SHX Text
P.SWIDERSKI
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text B-3
AutoCAD SHX Text B-2
AutoCAD SHX Text B-1
P R
O V
E D
A R
C H
I T
E C
T U
R A
L M
E C
H A
N I C
A L
E L
E C
T R
I C
A L
P L
U M
B I N
G
R E
V D
A T
E B
Y D
E S
C R
I P
T I O
N
D E
P A
R T
M E
H
E A
L T
H
A
M
R
V I C
E S
I N
D I A
N
H
E A
L T
H
S
E R
V I C
E
D I V
I S
I O
N
O
F
E
N G
I N
E E
R I N
G
S
E R
V I C
E S
D A
L L
A S
U
R
E E
T
S
U I T
E l l a s
T e x
DWN BY
CKD BY
SCALE
DATE
SHEET OF
PROJECT NUMBER
I N D
AI
N
H
EALTH
S
E R
V I C
E
P H
S
A
B
M I T
T A
L
P
A C
K A
G E
B
B
M I T
T A
L
P
A C
K A
G E
I S
S U
N
S T
R U
C T
I O
N
AutoCAD SHX Text
ELECTRICAL SYMBOL LEGEND & GENERAL NOTES
AutoCAD SHX Text
D.JARVIS
AutoCAD SHX Text
A.MARTINEZ
AutoCAD SHX Text
NONE
AutoCAD SHX Text E-1
AutoCAD SHX Text
AutoCAD SHX Text
NORTHERN CHEYENNE SERVICE UNIT
AutoCAD SHX Text
BILLINGS AREA INDIAN HEALTH SERVICE
AutoCAD SHX Text
NCSU BOILER & CHILLER REPLACEMENT DESIGN
AutoCAD SHX Text 12-13-2019
AutoCAD SHX Text
HHSI102201800008I
AutoCAD SHX Text
AutoCAD SHX Text
SD
AutoCAD SHX Text
HD
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
FS
AutoCAD SHX Text
TS
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text
FACP
AutoCAD SHX Text
OS
AutoCAD SHX Text
IC
AutoCAD SHX Text
PS
AutoCAD SHX Text
ANN
AutoCAD SHX Text
AutoCAD SHX Text E-100
AutoCAD SHX Text
%%UGENERAL
AutoCAD SHX Text
KEYED NOTE DESIGNATION
AutoCAD SHX Text
MECHANICAL EQUIPMENT DESIGNATION
AutoCAD SHX Text
SHEET DETAIL IS LOCATED
AutoCAD SHX Text
DETAIL NUMBER
AutoCAD SHX Text
%%UDETAIL DESIGNATION:
AutoCAD SHX Text
%%UCIRCUITING / RACEWAYS
AutoCAD SHX Text
%%UPANELBOARDS / EQUIPMENT
AutoCAD SHX Text
SWITCHED CONDUCTOR
AutoCAD SHX Text
GROUND CONDUCTOR
AutoCAD SHX Text
%%UCIRCUIT HOMERUNS:
AutoCAD SHX Text
PHASE CONDUCTOR(S)
AutoCAD SHX Text
NEUTRAL CONDUCTOR
AutoCAD SHX Text
%%UCIRCUIT DESIGNATION:
AutoCAD SHX Text
PP1-2
AutoCAD SHX Text
PANELBOARD NUMBER
AutoCAD SHX Text
CIRCUIT NUMBER(S)
AutoCAD SHX Text T
AutoCAD SHX Text
PAD MOUNTED TRANSFORMER
AutoCAD SHX Text
MDP
AutoCAD SHX Text
MAIN DISTRIBUTION PANELBOARD
AutoCAD SHX Text
POWER PANELBOARD
AutoCAD SHX Text
PP1
AutoCAD SHX Text
SPECIAL CABINET (TYPE AS INDICATED)
AutoCAD SHX Text
DISCONNECT / SAFETY SWITCH
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
EWC
AutoCAD SHX Text
AutoCAD SHX Text
MOTOR, NUMBER INDICATES HORSEPOWER RATING
AutoCAD SHX Text
PROVIDE THERMAL O.L. SWITCH ADJACENT TO ALL
AutoCAD SHX Text
MOTORS UNLESS OTHERWISE NOTED
AutoCAD SHX Text
%%URECEPTACLES / JUNCTION BOXES
AutoCAD SHX Text
20A DUPLEX RECEPTACLE, WALL MOUNTED
AutoCAD SHX Text
20A DUPLEX RECEPTACLE, CEILING MOUNTED
AutoCAD SHX Text
20A DUPLEX RECEPTACLE, IN FLOOR BOX
AutoCAD SHX Text
20A FOURPLEX RECEPTACLE, WALL MOUNTED
AutoCAD SHX Text
20A FOURPLEX RECEPTACLE, CEILING MOUNTED
AutoCAD SHX Text
20A FOURPLEX RECEPTACLE, IN FLOOR BOX
AutoCAD SHX Text
20A DUPLEX RECEPTACLE, GROUND FAULT CIRCUIT
AutoCAD SHX Text
INTERRUPTER (GFCI)
AutoCAD SHX Text
SPECIAL PURPOSE RECEPTACLE
AutoCAD SHX Text
(AMP RATING AS INDICATED)
AutoCAD SHX Text
WP/GFCI
AutoCAD SHX Text
GROUND FAULT CIRCUIT INTERRUPTER CONVENIENCE
AutoCAD SHX Text
RECEPTACLE (20A DUPLEX), MOUNTED ON UNISTRUT
AutoCAD SHX Text
ABOVE ROOF. INSTALLED IN A WEATHERPROOF OUTLET
AutoCAD SHX Text
BOX WITH WEATHERPROOF COVER
AutoCAD SHX Text
JUNCTION BOX, RECESSED / CEILING MOUNTED
AutoCAD SHX Text
JUNCTION BOX, WALL MOUNTED
AutoCAD SHX Text
JUNCTION BOX, FLUSH IN FLOOR
AutoCAD SHX Text
%%UGROUNDING / LIGHTNING PROTECTION
AutoCAD SHX Text
AIR TERMINAL
AutoCAD SHX Text
CONNECTION POINT
AutoCAD SHX Text
EXOTHERMIC WELD
AutoCAD SHX Text
GROUND CONNECTION
AutoCAD SHX Text
GROUND ROD, 3/4" X 10' COPPER CLAD STEEL
AutoCAD SHX Text
GROUNDING BUS BAR
AutoCAD SHX Text
LIGHTNING PROTECTION CONDUCTOR
AutoCAD SHX Text
LP
AutoCAD SHX Text
%%ULIGHTING
AutoCAD SHX Text
OS
AutoCAD SHX Text A
AutoCAD SHX Text 1, a
AutoCAD SHX Text 1,a
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
2'X4' LIGHT FIXTURE
AutoCAD SHX Text
A = FIXTURE TYPE
AutoCAD SHX Text
1 = CIRCUIT NUMBER
AutoCAD SHX Text a = SWITCH CONTROLLING FIXTURE
AutoCAD SHX Text 1, a
AutoCAD SHX Text A
AutoCAD SHX Text
1'X4' LIGHT FIXTURE
AutoCAD SHX Text
A = FIXTURE TYPE
AutoCAD SHX Text
1 = CIRCUIT NUMBER
AutoCAD SHX Text a = SWITCH CONTROLLING FIXTURE
AutoCAD SHX Text
2'X2' LIGHT FIXTURE
AutoCAD SHX Text
A = FIXTURE TYPE
AutoCAD SHX Text
1 = CIRCUIT NUMBER
AutoCAD SHX Text a = SWITCH CONTROLLING FIXTURE
AutoCAD SHX Text
2'X4' LIGHT FIXTURE WITH EMERGENCY
AutoCAD SHX Text
BALLAST OR EMERGENCY BATTERY PACK
AutoCAD SHX Text
2'X2' LIGHT FIXTURE WITH EMERGENCY
AutoCAD SHX Text
BALLAST OR EMERGENCY BATTERY PACK
AutoCAD SHX Text
RECESSED OR CEILING MOUNTED LIGHT
AutoCAD SHX Text
FIXTURE; LETTER DENOTES FIXTURE TYPE
AutoCAD SHX Text
WALL MOUNTED LIGHT FIXTURE;
AutoCAD SHX Text
LETTER DENOTES FIXTURE TYPE
AutoCAD SHX Text
CEILING OR PENDANT MOUNTED LIGHT FIXTURE;
AutoCAD SHX Text
LETTER DENOTES FIXTURE TYPE
AutoCAD SHX Text
EXTERIOR LIGHT POLE WITH FIXTURE; LETTER DENOTES
AutoCAD SHX Text
FIXTURE TYPE
AutoCAD SHX Text
CEILING-MOUNTED DOUBLE-FACE EXIT LIGHT FIXTURE;
AutoCAD SHX Text
LETTER DENOTES FIXTURE TYPE, ARROWS INDICATE
AutoCAD SHX Text
DIRECTIONAL ARROWS
AutoCAD SHX Text
CEILING-MOUNTED SINGLE-FACE EXIT LIGHT FIXTURE;
AutoCAD SHX Text
LETTER DENOTES FIXTURE TYPE
AutoCAD SHX Text
WALL-MOUNTED EXIT LIGHT FIXTURE; LETTER DENOTES
AutoCAD SHX Text
FIXTURE TYPE, ARROW INDICATES DIRECTIONAL ARROW
AutoCAD SHX Text
EXTERIOR WALKWAY LIGHT FIXTURE; LETTER DENOTES
AutoCAD SHX Text
FIXTURE TYPE
AutoCAD SHX Text A
AutoCAD SHX Text
%%USWITCHES
AutoCAD SHX Text a
AutoCAD SHX Text 2,a
AutoCAD SHX Text
SINGLE POLE SWITCH, LETTER INDICATES CONTROL
AutoCAD SHX Text
DOUBLE POLE SWITCH, LETTER INDICATES CONTROL
AutoCAD SHX Text 3,a
AutoCAD SHX Text
THREE-WAY SWITCH, LETTER INDICATES CONTROL
AutoCAD SHX Text 4,a
AutoCAD SHX Text
FOUR-WAY SWITCH, LETTER INDICATES CONTROL
AutoCAD SHX Text D
AutoCAD SHX Text
DIMMER SWITCH, LED TYPE UNLESS
AutoCAD SHX Text
OTHERWISE NOTED
AutoCAD SHX Text T
AutoCAD SHX Text
MOTOR RATED SWITCH WITH THERMAL OVERLOAD
AutoCAD SHX Text K
AutoCAD SHX Text
KEY OPERATED WALL SWITCH
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
WP
AutoCAD SHX Text
WEATHERPROOF SWITCH
AutoCAD SHX Text
MOTION DETECTOR, WALL MOUNTED
AutoCAD SHX Text
MD
AutoCAD SHX Text
MD
AutoCAD SHX Text
MOTION DETECTOR, CEILING MOUNTED
AutoCAD SHX Text
OCCUPANCY SENSOR WITH OVERRIDE SWITCH,
AutoCAD SHX Text
WALL MOUNTED
AutoCAD SHX Text
OCCUPANCY SENSOR WITH OVERRIDE SWITCH,
AutoCAD SHX Text
CEILING MOUNTED
AutoCAD SHX Text
%%UFIRE ALARM SYSTEM
AutoCAD SHX Text
FIRE ALARM CONTROL PANEL
AutoCAD SHX Text
FIRE ALARM ANNUNCIATOR PANEL
AutoCAD SHX Text
FIRE ALARM MANUAL PULL STATION, WALL MOUNTED
AutoCAD SHX Text
FIRE ALARM HORN / STROBE, WALL MOUNTED
AutoCAD SHX Text
FIRE ALARM FLASHING STROBE LIGHT, WALL MOUNTED
AutoCAD SHX Text
FIRE ALARM BELL, WALL MOUNTED
AutoCAD SHX Text
HEAT DETECTOR
AutoCAD SHX Text
DUCT DETECTOR
AutoCAD SHX Text
TAMPER SWITCH
AutoCAD SHX Text
FLOW SWITCH
AutoCAD SHX Text
PRESSURE SWITCH
AutoCAD SHX Text
HH
AutoCAD SHX Text
MH
AutoCAD SHX Text
AutoCAD SHX Text
%%UCOMMUNICATIONS / SPECIAL SYSTEMS
AutoCAD SHX Text
TV
AutoCAD SHX Text
COMBINATION TELEPHONE/DATA OUTLET, WALL MOUNTED
AutoCAD SHX Text
COMBINATION TELEPHONE/DATA OUTLET, IN FLOOR BOX
AutoCAD SHX Text
COMPUTER/DATA OUTLET, WALL MOUNTED
AutoCAD SHX Text
COMPUTER/DATA OUTLET, WALL MOUNTED
AutoCAD SHX Text
TELEPHONE OUTLET, WALL MOUNTED
AutoCAD SHX Text
CCTV CAMERA, WALL MOUNTED
AutoCAD SHX Text
WALL MOUNTED SPEAKER
AutoCAD SHX Text
CEILING SPEAKER, FLUSH MOUNTED
AutoCAD SHX Text
INTERCOM OUTLET, WALL MOUNTED
AutoCAD SHX Text
CABLE TV OUTLET, WALL MOUNTED
AutoCAD SHX Text M
AutoCAD SHX Text
%%UDISTRIBUTION
AutoCAD SHX Text
CONDUIT ROUTING DOWNWARD
AutoCAD SHX Text
CONDUIT ROUTING UPWARD
AutoCAD SHX Text
CONDUIT CAPPED END
AutoCAD SHX Text
UTILITY PRIMARY
AutoCAD SHX Text
EXISTING CIRCUIT
AutoCAD SHX Text
UNDERGROUND SECONDARY (ELECTRICAL)
AutoCAD SHX Text
OVERHEAD CIRCUIT
AutoCAD SHX Text
25KV
AutoCAD SHX Text
(EX)
AutoCAD SHX Text E
AutoCAD SHX Text
OH
AutoCAD SHX Text
UNDERGROUND COMMUNICATIONS
AutoCAD SHX Text
UC
AutoCAD SHX Text
UNDERGROUND COMMUNICATIONS AND FIRE ALARM
AutoCAD SHX Text
UC/FA
AutoCAD SHX Text
UTILITY METER
AutoCAD SHX Text
MANHOLE,…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .