Attachment J03 - Opt Remodel Combined Drawings.pdf
PDF 23 MB Posted
- Attached to
- Fort Washakie Optometry & HIM Remodel
- Solicitation number
- 75H70123R00061
About this file
This solicitation notice is for construction services for the renovation of the optometry and medical records departments at the Fort Washakie Health Center in Fort Washakie, Wyoming. The Indian Health Service seeks to award a firm fixed price contract for a period of 300 calendar days from notice to proceed. The project scope involves renovating approximately 3,661 total square feet including the optometry, medical records, and office spaces. The construction magnitude is estimated between $1,000,000 to $5,000,000. A mandatory site visit will be held on June 14, 2023 at 10:00 AM local time. Interested parties should monitor the System for Award Management for solicitation amendments. The North American Industry Classification System code is 236220 and the size standard is $45 million in average annual revenue for the last three years.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
261 North Court Avenue
Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
ARCHITECTSCONSULTANTSOWNER
IHS Project No: 75H70121F30009 Fort Washakie, WY
INDIAN HEALTH SERVICE
FACILITIES DESIGN & CONSTRUCTION
Two Renaissance Square
40 N Central Ave
Phoenix, AZ 85004
Phone: (602) 364-5300
Strike Consulting Group LLC
205 S. 3rd Street
Lander, WY 82520
Phone: (307) 335-8466
Turner Structural Eng.
2806 N Alvernon Way, Suite 400
Tucson, AZ 85712
Phone: (520) 323-3422
Adams & Associates
6422 E. Speedway Blvd., Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
Adams & Associates
6422 E. Speedway Blvd. Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
CIVIL STRUCTURAL MECHANICAL ELECTRICAL
INDIAN HEALTH SERVICE
WRSU OPTOMETRY BUILDING &
OFFICE SPACE DESIGN
May 5, 2022
100% CD
C D
M ay
, 2
W R
S U
O P
T O
M E T R
Y B
U
IL
D
IN
G
O F F
IC
E S
P A
C E D
E S
IG
N
B W
S P ro je ct N o.
.7
IN
D
IA
N
H E A
LT
H
S E R
V
IC
E
Attachment J03 - Optometry Remodel Combined Drawings Solicitation Number 75H701-23-R-00061
EARTH
POROUS FILL, STONE, OR GRAVEL
CONCRETE
CONCRETE MASONRY UNIT
STEEL
ALUMINUM
PLYWOOD
CONCRETE,
PLASTER, OR GWB
WOOD GLASS
MASONRY
GYPSUM WALL BOARD
MEMBRANE
ROUGH WOOD, NONCONTINUOUS
ROUGH WOOD, CONTINUOUS
PLASTER, SAND, CEMENT, OR GROUT
RIGID INSULATION
INSULATION BLANKET, BATTS
SECTION
ELEVATION
2 4
2 4
ROOFING OR FLASHING
DRAWING TITLE WITH DETAIL
NUMBER AND SCALE
COLUMN GRID
WALL TAG
GRAPHIC SCALE
EQUIPMENT TAG
REVISION CLOUD
E1
ELEVATION INDICATOR
NORTH ARROW
N
BUILDING SECTION
WALL SECTION
ENLARGED AREA OR DETAIL CALLOUT
EXTERIOR ELEVATION
INTERIOR ELEVATION
DOOR TAG
WINDOW TAG
KEYNOTE
SAFETY GLASS INDICATOR
ROOM TAG
Room name
A101
A101
A101
A101
A101
0' 2' 4' 8'
F
16'- 0" A.F.F.
FF ELEV
DOOR NUMBER
DOOR MARK
DRAWING
NUMBER
View Name
SCALE: 1/8" = 1'-0"
SECTION LETTER
SHEET WHERE DRAWN
ELEVATION REFERENCE NO
SHEET WHERE DRAWN
ELEVATION REFERENCE NO
SHEET WHERE DRAWN
DETAIL NUMBER
SHEET WHERE DRAWN
REVISION NUMBER
CLOUD ENCLOSES REVISION
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
E
H
N M
E
A R
P
T O F
T
C D
SU
S
A
E
TAE L
&H
N V I
S E R
U M A
H
BILLINGS AREA
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S i g n e d . . .
CE
R T
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2022
ARCHITECTS
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
IHS PROJECT NO.
C
B
A
C
B
A
SHEET TITLE
G1.0
ABBREVIATIONS &
SYMBOLS
May 5, 2022 - 100% CD 1818.700
RL
INDIAN HEALTH
SERVICE
WRSU OPTOMETRY
BUILDING & OFFICE
SPACE DESIGN
Fort Washakie, WY
75H70121F30009
04/
/2
CIVIL
Strike Consulting Group LLC
205 S. 3rd Street
Lander, WY 82520
Phone: (307) 335-8466
STRUCTURAL
Turner Structural Eng.
2806 N Alvernon Way, Suite 400
Tucson, AZ 85712
Phone: (520) 323-3422
MECHANICAL
Adams & Associates
6422 E. Speedway Blvd., Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
ELECTRICAL
Adams & Associates
6422 E. Speedway Blvd.
Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
ABBREVIATIONSSYMBOLS
MATERIALS
@ AT
A/C AIR CONDITIONING
AB ANCHOR BOLT
ABC AGGREGATE BASE COURSE
AC ACOUSTICAL CEILING
ADA AMERICAN WITH DISABILITIES
ACT
ADJ ADJACENT
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
AFF ABOVE FINISH FLOOR
AGG AGGREGATE
ALT ALTERNATE
ALUM ALUMINUM
ANCH ANCHOR, ANCHORAGE
ANOD ANODIZED
BD BOARD
BEDRM BEDROOM
BFF BELOW FINISH FLOOR
BLDG BUILDING
BLK(G) BLOCK(ING)
BM BENCH MARK
BO BOTTOM OF
BOT BOTTOM
BRG BEARING
BRK BRICK
BSMT BASEMENT
BUR BUILT UP ROOFING
C CHANNEL
C/C CENTER TO CENTER
CAB CABINET
CB CHALKBOARD, CATCH BASIN
CEM CEMENT
CFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CFOI CONTRACTOR FURNISHED,
OWNER INSTALLED
CG CORNER GUARD
CI CAST IRON
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLR CLEAR(ANCE)
CMP CORRUGATED METAL PIPE
CMTS COMMENTS
CMU CONCRETE MASONRY UNITS
CMWP COMPOSITE METAL WALL
PANEL
CNPY CANOPY
CO CLEAN OUT
COL COLUMN
COMB COMBINATION
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUE (OUS)
CORR CORRIDOR, CORRUGATED
CPT CARPET
CSK COUNTERSINK
CT CERAMIC TILE
CU CUBIC
CU FT CUBIC FOOT
CW COLD WATER
D DEPTH
DEMO DEMOLISH
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DP DAMPPROOFING
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DWC DRYWALL CHANNELS (HAT)
DWG DRAWING
E EAST
EA EACH
EF EACH FACE
EFS EXTERIOR FINISH SYSTEM
EIFS EXT. INSULATION FINISH
SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRIC(AL)
ELEV ELEVATION, ELEVATOR
EMER EMERGENCY
EP EPOXY PAINT
EQ EQUAL
EQUIP EQUIPMENT
ES EXPOSED STRUCTURE
EST ESTIMATE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWWM ELECTRICALLY WELDED WIRE
MESH
EXC EXCAVAT(E) (ION)
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
F FAHRENHEIT
F/ FROM
FA FIRE ALARM
FAB FABRICATE
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FIN FINISH(ED)
FLA FLASHING
FLEX FLEXIBLE
FLUOR FLUORESCENT
FO FACE OF
FP FIREPROOF
FR FIRE RETARDANT
FRP FIBER REINFORCED PLASTIC
FS FLOOR SINK
FT FOOT, FEET
FTG FOOTING
FUR FURRED(ING)
FUT FUTURE
FV FIELD VERIFY
GA GAGE, (GAUGE)
GALV GALVANIZED
GC GENERAL CONTRACT(OR)
GD GRADE
GL GLASS, GLAZING
GWB GYPSYUM WALLBOARD
GYP GYPSUM
HB HOSE BIBB
HC HOLLOW CORE
HDBD HARDBOARD
HDWD HARDWOOD
HDWR HARDWARE
HIW HIGH IMPACT WOOD
FIBER BOARD
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HT HEIGHT
HVAC HEATING VENTILATING
AIR CONDITIONING
HW HOT WATER
ICF INSULATED CONCRETE FORM
ICMWP INSULATED COMPOSITE
METAL WALL PANEL
ID INSIDE DIAMETER
IE INVERT ELEVATION
IN INCH(ES)
INCL INCLUDING
INS INSULATION
INT INTERIOR
JC JANITORS CLOSET
JST JOIST
JT JOINT
KD KNOCKED DOWN
KIT KITCHEN
KO KNOCK OUT
KP KICK PLATE
L LENGTH, LONG
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LF LINEAR FEET
LH LEFT HAND
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LP LOW POINT
LT LIGHT
LTWT LIGHTWEIGHT
LVR LOUVER
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDIUM
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODULAR
MOV MOVABLE
MTD MOUNTED
MTL METAL
MWP METAL WALL PANEL (SYSTEM)
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT, (OFOI)
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION
COEFFICIENTS
NTS NOT TO SCALE
O/ OVER
OA OVERALL
OC ON CENTER(S)
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED,
CONTRACTOR INSTALLED
OFF OFFICE
OFOI OWNER FURNISHED,
OWNER INSTALLED
OH OVERHEAD, OPPOSITE HAND
OPG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
OSB ORIENTED STRAND BOARD
P PAINT(ED)
PAR PARALLEL
PART PARTITION
PART BD PARTICLE BOARD
PC PIECE
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PERF PERFORATE(D)
PERIM PERIMETER
PERP PERPENDICULAR
PF PREFABRICATES
PJ PANEL JOINT
PL PLASTER, PLATE,
PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PNL PANEL
PO POWER OPERATED
PR PAIR
PREFAB PREFABRICATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PTD PAPER TOWEL DISPENSER
PTR PAPER TOWEL RECEPTOR
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
PWD PLYWOOD
QT QUARRY TILE
QTR QUARTER
QTY QUANTITY
(R) RECESSED
R RADIUS, RISER ROUND
RA RETURN AIR
RB RESILIENT BASE
RCP REINFORCED CONCRETE PIPE,
REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
RELO RELOCATION
REPL REPLACE
REQ'D REQUIRED
RES RESILIENT
REV REVISION(S), REVISED
RF RIGID FIBERGLASS
RFG ROOFING
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RWL RAINWATER LEADER
(S) SURFACE MOUNTED
S SEALED, SOUTH
SC SOLID CORE
SCHED SCHEDULE
SD STORM DRAIN
SDG SIDING
SECT SECTION
SF SQUARE FEET
SHEET SHEET
SHWR SHOWER
SIM SIMILAR
SIP STRUCTURAL INSULATED
PANEL
SM SHEET METAL
SP SOUNDPROOF
SPECS SPECIFICATIONS
SPKR SPEAKER
SPL SPECIAL
SQ SQUARE
SS SERVICE SINK,
STAINLESS STEEL
ST STREET
STC SOUND TRANSMISSION
COEFFCIENT
STD STANDARD
STL STEEL
STOR STORAGE
STRUC STRUCTURAL
SUSP SUSPENDED
SV SEAMLESS VINYL
SW SWITCH
SWR SEWER
SYM SYMMETRY(ICAL)
T THICKNESS, TEE
T&G TONGUE & GROOVE
TB TACKBOARD
TBD TO BE DETERMINED
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPERATURE, TEMPORARY
TERR TERRAZZO
THK THICK(NESS)
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOIL TOILET
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TV TELEVISION
TYP TYPICAL
U URINAL
UG UNDERGROUND
UL UNDERWRITERS LABORATORY
UNF UNFINISHED
UNO UNLESS NOTED OTHERWISE
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VNR VENEER
VPL VENEER PLATER
VWC VINYL WALL COVERING
W WIDTH, WIDE, WEST
W/ WITH
W/O WITHOUT
W/W WALL TO WALL
WC WATER CLOSET
WD WOOD
WDW WINDOW
WH WALL HUNG, WATER HEATER
WI WROUGHT IRON
WM WIRE MESH
WP WATERPROOFING
WR WATER REPELLENT
WS WEATHERSTRIP
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
YD YARD
SEWER LINE
SEWER LINE
SEWER LINE
N
N FORK RD
H W
Y 287
H W
Y 287
PROJECT LOCATION BLAC
K C
O
AL D
R
N O
R K
O K
S T
1ST ST
2ND ST
HEREFORD LN
SOUTH FORK LITTLE
WIND RIVER
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
E
H
N M
E
A R
P
T O F
T
C D
SU
S
A
E
TAE L
&H
N V I
S E R
U M A
H
BILLINGS AREA
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S i g n e d . . .
CE
R T
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2022
ARCHITECTS
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
IHS PROJECT NO.
C
B
A
C
B
A
SHEET TITLE
G2.0
PROJECT INFORMATION
& SHEET INDEX
May 5, 2022 - 100% CD 1818.700
RL
INDIAN HEALTH
SERVICE
WRSU OPTOMETRY
BUILDING & OFFICE
SPACE DESIGN
Fort Washakie, WY
75H70121F30009
04/
/2
CIVIL
Strike Consulting Group LLC
205 S. 3rd Street
Lander, WY 82520
Phone: (307) 335-8466
STRUCTURAL
Turner Structural Eng.
2806 N Alvernon Way, Suite 400
Tucson, AZ 85712
Phone: (520) 323-3422
MECHANICAL
Adams & Associates
6422 E. Speedway Blvd., Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
ELECTRICAL
Adams & Associates
6422 E. Speedway Blvd.
Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
GENERAL NOTES
1. ALL CONSTRUCTION TO CONFORM TO THE LATEST PUBLISHED EDITION OF NATIONALLY RECOGNIZED CODES, STANDARDS AND GUIDELINES, INCLUDING THE
FOLLOWING: NATIONAL FIRE CODES; INTERNATIONAL BUILDING CODE (IBC); INTERNATIONAL RESIDENTIAL CODE (IRC); ARCHITECTURAL BARRIERS ACT (ABA);
INTERNATIONAL ENERGY CONSERVATION CODE (IECC); ASHRAE 62.1 – VENTILATION AND ACCEPTABLE INDOOR AIR QUALITY.
2. THE CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL
PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT,ETC. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES FOR PROCEDURE OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERETO (NOR SHALL OBSERVATION
VISITS TO THE SITE INCLUDE INSPECTION OF THESE ITEMS).
3. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT.
4. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDA.
5. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS, AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF HE CHOOSES AN OPTION, CONTRACTOR SHALL BE
RESPONSIBLE FOR ALL NECESSARY CHANGES AND SHALL COORDINATE ALL DETAILS.
6. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT.
7. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN.
8. CONTRACTOR SHALL VERIFY THE ADEQUACY AND LOCATION OF EXISTING UTILITIES. VERIFY INVERTS TO ASSURE THAT PROPER SLOPES CAN BE OBTAINED.
PROJECT DESCRIPTION
THIS PROJECT CONSISTS OF RENOVATING THE HIM DEPARTMENT WITHIN THE MAIN CLINIC, COMPLETE INTERIOR
RENOVATION OF BUILDING 74, AND COMPLETE INTERIOR RENOVATION OF BUILDING 76. NEW PARKING SPACES
INFRONT OF BUILDING 74 AND BUILDING 76 WILL ALSO BE INCLUDED IN THIS PROJECT.
LOCATION
OWNERS:
INDIAN HEALTH SERVICE
WINDRIVER SERVICE UNIT
ADDRESS:
29 BLACK COAL DR.
FORT WASHAKIE, WY
DRAWING INDEX
PROJECT LOCATION,
BUILDING 76
N
N.T.S.
GENERAL
G0.0 COVER SHEET
G1.0 ABBREVIATION & SYMBOLS
G2.0 PROJECT INFORMATION & SHEET INDEX
ARCHITECTURAL SITE
A0.1 ARCHITECTURAL SITE PLAN
A0.2 ARCHITECTURAL SITE DETAILS
CIVIL
C1.0 CIVIL SITE EXISTING CONDITIONS
C2.0 UNIT 74 PARKING SITE PLAN
C3.0 UNIT 76 PARKING SITE PLAN
STRUCTURAL
S1.1 STANDARD STRUCTURAL NOTES AND DETAILS
S1.2 BLDG 74 - FOUNDATION AND FRAMING PLANS
S1.3 BLDG 76 - FOUNDATION AND FRAMING PLANS
ARCHITECTURAL
A1.0 HIM DEPARTMENT - CODE REVIEW
A1.1 HIM DEPARTMENT - FLOOR PLAN
A1.2 HIM DEPARTMENT - REFLECTED CEILING PLAN
A1.3 HIM DEPARTMENT - FINISH & DOOR SCHEDULE
A2.0 BLDG 74 - CODE REVIEW
A2.1 BLDG 74 - FLOOR PLAN
A2.2 BLDG 74 - REFLECTED CEILING PLAN
A2.3 BLDG 74 - ROOF PLAN
A2.4 BLDG 74 - FINISH & DOOR SCHEDULE
A3.0 BLDG 76 - CODE REVIEW
A3.1 BLDG 76 - FLOOR PLAN
A3.2 BLDG 76 - REFLECTED CEILING PLAN
A3.3 BLDG 76 - ROOF PLAN
A3.4 BLDG 76 - FINISH & DOOR SCHEDULE
A4.0 STANDARD WALL TYPES & DETAILS
A4.1 STANDARD INTERIOR ELEVATIONS & MILLWORK
MECHANICAL
M0.1 STANDARD MECHANICAL DETAILS
M1.1 HIM DEPT - MECHANICAL FLOOR PLANS
M2.1 BLDG 74 - MECHANICAL FLOOR PLANS
M2.2 BLDG 74 - MECHANICAL SCHEDULE
M3.1 BLDG 76 - MECHANICAL FLOOR PLANS
M3.2 BLDG 76 - MECHANICAL SCHEDULES
FIRE PROTECTION
FP1.1 FIRE PROTECTION FLOOR PLANS
PLUMBING
P.01 PLUMBING NOTES AND INFORMATION
P1.1 PLUMBING FLOOR PLANS - HIM DEPARTMENT
P1.2 PLUMBING NOTES, SCHEDULES AND DETAILS - HIM DEPT.
P2.1 PLUMBING DEMO FLOOR PLANS - BLDG 74
P2.2 PLUMBING FLOOR PLANS - BLDG 74
P2.3 PLUMBING ISOMETRICS - BLDG 74
P2.4 PLUMBING NOTES, SCHEDULES AND DETAILS - BLDG 74
P3.1 PLUMBING FLOOR PLANS - BLDG 76
P3.2 PLUMBING ISOMETRICS
P3.3 PLUMBING NOTES, SCHEDULES AND DETAILS - BLDG 76
ELECTRICAL
E0.1 ELECTRICAL GENERAL INFORMATION
E1.1 ELECTRICAL SITE PLAN
E2.1 HIM DEPT - ELECTRICAL DEMO FLOOR PLANS
E2.2 HIM DEPT - ELECTRICAL FLOOR PLANS
E3.1 BLDG 74 - ELECTRICAL DEMO FLOOR PLANS
E3.2 BLDG 74 - ELECTRICAL FLOOR PLANS
E4.1 BLDG 76 - ELECTRICAL DEMO FLOOR PLANS
E4.2 BLDG 76 - ELECTRICAL FLOOR PLANS
E5.1 ELECTRICAL ONE-LINES AND SCHEDULES
E5.2 ELECTRICAL SCHEDULES AND DETAILS
PROJECT LOCATION,
BUILDING 74
PROJECT LOCATION,
HIM DEPARTMENT
LOCATION MAP - FORT WASHAKIE HEALTH CENTER
VICINITY MAP - FORT WASHAKIE
N.T.S.
TRUE
N
PROJECT
SEWER LINE
DN
x x x x x x x x x x x x x x x x x x x x x x x x
(E) S
(E) S
(E) S (E) S (E) S
(E
0E
(E
0E
(E
0E
(E
0E
0E
0E
0E
0E
(E ) 0E
(E ) 0E
(E ) 0E
(E ) 0E
(E ) 0E
(E ) O
C
(E ) O
C (E
) O C
(E ) O
C (E
) O C
(E ) S
(E ) S
(E ) S
(E ) S
(E ) S
(E S
(E S
(E S
(E S
(E) OE
(E) OE
(E) OE (E) OE (E) OE (E) OE
(E O
C
(E O
C
(E O
C
BLDG
BLDG
BLDG
BIA
OFFICE
BLDG
BLACKCOLE ST.
A3.1
A2.1
A1.1
HIM DEPT
117117
N
S T
S T.
EXISTING BUILDINGS
CONCRETE SIDEWALKS, PATIO AND DRIVEWAYS
PROPOSED CHAIN LINK FENCE
BUILDING FOOTPRINT
(E) CHAINLINK FENCE
SITE VISIBILITY TRIANGLES
(E) WATER LINEW W
(E) SEWER LINES S
(E) GAS LINESG G
(E) UNDERGROUND ELECTRICAL LINES
CONTOUR LINES
(E) OVERHEAD ELECTRICAL LINESOHE
PROPOSED UNDERGROUND ELECTRICAL LINES
SIDEWALK SCUPPERSC
EXISTING(E)
SEWER MANHOLE
UGE
PROPOSED WATER LINEW W
PROPOSED SEWER LINES S
UGE
PROPOSED GAS LINESG G
ss SEWER CLEANOUT
SITE PLAN LEGEND
x x x x
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
E
H
N M
E
A R
P
T O F
T
C D
SU
S
A
E
TAE L
&H
N V I
S E R
U M A
H
BILLINGS AREA
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S i g n e d . . .
CE
R T
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2022
ARCHITECTS
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
IHS PROJECT NO.
C
B
A
C
B
A
SHEET TITLE
A0.1
ARCHITECTURAL SITE
PLAN
May 5, 2022 - 100% CD 1818.700
RL
INDIAN HEALTH
SERVICE
WRSU OPTOMETRY
BUILDING & OFFICE
SPACE DESIGN
Fort Washakie, WY
75H70121F30009
04/
/2
CIVIL
Strike Consulting Group LLC
205 S. 3rd Street
Lander, WY 82520
Phone: (307) 335-8466
STRUCTURAL
Turner Structural Eng.
2806 N Alvernon Way, Suite 400
Tucson, AZ 85712
Phone: (520) 323-3422
MECHANICAL
Adams & Associates
6422 E. Speedway Blvd., Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
ELECTRICAL
Adams & Associates
6422 E. Speedway Blvd.
Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
N
1" = 20'-0"1
ARCHITECTURAL SITE PLAN
0' 5' 10' 20'
SITE PLAN GENERAL NOTES
A. UNDERGROUND UTILITY LOCATIONS HAVE NOT BEEN VERIFIED FOR LOCATION OR
SIZE. CONTRACTOR TO VERIFY LOCATION AND SIZE OF UNDERGROUND UTILITIES
PRIOR TO BEGINNING CONSTRUCTION.
B. CONTRACTOR IS RESPONSIBLE FOR ALL BARRICADES & SAFETY CONCERNS
WITHINT & ADJACENT TO CONSTRUCTION.
C. FIELD VERIFY ALL EXISTING CONDITIONS & DIMENSIONS PRIOR TO CONSTRUCTION
D. REFER TO CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL & ELECTRICAL
DRAWINGS FOR MORE INFORMATION & UTILITY COORDINATION
E. CONTACTOR SHALL PATH & REPAIR ALL EXISTING FINISHED ADJACENT TO
DEMOLITION AS REQUIRED.
102 (E) DRIVEWAY
103 NEW CONCRETE PARKING, SEE CIVIL
114 NEW 8' WIDE DOUBLE GATE, MODIFY (E) FENE FOR NEW GATE
115 (E) STORAGE STRUCTURE
117 (E) CHAINLINK FENCE
KEY NOTES
1'-0" VERIFY SITE DIMENSION
2'-10"
4"M A
X
LANDING,
SEE STRUCT
HANDRAIL RETURN,
SEE PLAN
4"
RAMP,
SEE STRUCT
1 1/2" DIA TUBE STL,
PAINTED
SIDEWALK,
CIVIL
ALL JOINTS WELDED
AND SANDED SMOOTH
1.5" DIA. TUBE STEEL
RAILING PER CODE
HANDRAIL WELDED
TO EMBED PLATE
SAND
CONCRETE LANDING,
SEE STRUCT
1' - 0" 1' - 0"
VERIFY SITE DIMS
3'
TYP
1"
1' - 0"2" TOOLED GROOVE
SIDEWALK
HANDRAIL WELDED
TO EMBED PLATE
FELT JOINT,
SEE STRUCT
CONCRETE STEPS,
SEE STRUCT
1' - 0" 6" 4 1/4"
3 1/2"
5' - 0"
3 1/2"
EXTERIOR FACE OF BUILDING
(N) SIDEWALK,
SEE CIVIL
ID
3' - 0"
ID
3' - 0"
ID
5'
5'
/2
3'
/2
4'
4'
4'
/4
EQ EQ
(E) ENTRY DOOR
DN
RAMP
DN
RAMP
DN
CONCRETE LANDING,
SEE STRUCT
CONCRETE RAMP,
SEE STRUCT
CONCRETE LANDING,
SEE STRUCT
DRAINAGE
DECOMPOSED GRANITE,
COLOR SELECTED BY OWNER
TYP EMBED BASE PLATE,
SEE STRUCT
1 1/2" ⌀ HANDRAIL,
PAINTED
VIF
11' - 3 1/2"
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
E
H
N M
E
A R
P
T O F
T
C D
SU
S
A
E
TAE L
&H
N V I
S E R
U M A
H
BILLINGS AREA
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S i g n e d . . .
CE
R T
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2022
ARCHITECTS
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
IHS PROJECT NO.
C
B
A
C
B
A
SHEET TITLE
A0.2
ARCHITECTURAL SITE
DETAILS
May 5, 2022 - 100% CD 1818.700
RL
INDIAN HEALTH
SERVICE
WRSU OPTOMETRY
BUILDING & OFFICE
SPACE DESIGN
Fort Washakie, WY
75H70121F30009
04/
/2
CIVIL
Strike Consulting Group LLC
205 S. 3rd Street
Lander, WY 82520
Phone: (307) 335-8466
STRUCTURAL
Turner Structural Eng.
2806 N Alvernon Way, Suite 400
Tucson, AZ 85712
Phone: (520) 323-3422
MECHANICAL
Adams & Associates
6422 E. Speedway Blvd., Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
ELECTRICAL
Adams & Associates
6422 E. Speedway Blvd.
Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
1/2" = 1'-0"1
RAMP HANDRAIL
1/2" = 1'-0"2
EXTERIOR STEPS
1/2" = 1'-0"3
ENLARGE RAMP PLAN
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
IHS PROJECT NO.
C
B
A
C
B
A
SHEET TITLE
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
E
H
N
ME
AR P
T
OF
T
C D
SU
S
A
E
TAE L &H
N
VI
SER
UMA
H
BILLINGS AREA
ARCHITECTS
C1.0
CIVIL SITE
EXISTING CONDITIONS
April 8, 2022 - 100% CD 1818.700
RL
INDIAN HEALTH
SERVICE
WRSU OPTOMETRY
BUILDING & OFFICE
SPACE DESIGN
Fort Washakie, WY
75H70121F30009
CIVIL
Strike Consulting Group LLC 205 S. 3rd Street Lander, WY 82520 Phone: (307) 335-8466
STRUCTURAL
Turner Structural Eng.
3026 N Country Club Tucson, AZ 85716 Phone: (520) 323-3422
MECHANICAL
Adams & Associates 6422 E. Speedway Blvd., Unit 130 Tucson, AZ 85710 Phone: (520) 323-3858
ELECTRICAL
Adams & Associates 6422 E. Speedway Blvd.
Unit 130 Tucson, AZ 85710 Phone: (520) 323-3858
Attachment J03 - Optometry Remodel Combined Drawings Solicitation Number 75H701-23-R-00061
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
UNIT 74 FFE= 5581.42
AutoCAD SHX Text
UNIT 75 FFE= 5581.35
AutoCAD SHX Text
UNIT 76 FFE= 5580.53
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
UPSTREAM M.H. NOT FOUND
AutoCAD SHX Text B.M. 1
AutoCAD SHX Text
N=912614.96 E=1933353.24 EL=5576.52
AutoCAD SHX Text B.M. 2
AutoCAD SHX Text
N=912670.73 E=1933121.96 EL=5578.29
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
OVERHEAD POWER
AutoCAD SHX Text
GAS SERVICE
AutoCAD SHX Text
SEWER LINE
AutoCAD SHX Text
FIRE HYDRANT
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
UTILITY POLE
AutoCAD SHX Text G
AutoCAD SHX Text
GAS METER
AutoCAD SHX Text S
AutoCAD SHX Text
SEWER MANHOLE
AutoCAD SHX Text
OVERHEAD COMM
AutoCAD SHX Text
CHAINLINK FENCE
AutoCAD SHX Text NOTE: SANITARY SEWER INFORMATION SHOWN HEREON IS A COMPILATION OF SURVEY DATA AND SANITARY SEWER INFORMATION SHOWN HEREON IS A COMPILATION OF SURVEY DATA AND AS-BUILT INFORMATION PROVIDED BY IHS. BENCHMARK COORDINATES SHOWN HERON ARE BASED ON SPC83 AND NAD88 GRID READINGS AVERAGED OBSERVATION USING DUAL FREQUENCY TRIMBLE R10 RECEIVER AND TRIBLE R8s BASE STATION. CONTRACTOR TO VERIFY ALL EXISTING UTILITIES.
AutoCAD SHX Text
BLACK COAL DRIVE
AutoCAD SHX Text 1st STREET
AutoCAD SHX Text
WASHAKIE STREET
RETURN CURB
NOT TO SCALE
RESERVED
PARKING
VAN
ACCESSIBLE
ADA PARKING SIGN
NOT TO SCALE
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
PREL
IM
IN
AR
Y - N
OT F
OR C
ONST
RUCTIO
N
FO
R R
EV
IEW
PURPOSE
S O
NLY
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
IHS PROJECT NO.
C
B
A
C
B
A
SHEET TITLE
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
E
H
N
ME
AR P
T
OF
T
C D
SU
S
A
E
TAE L &H
N
VI
SER
UMA
H
BILLINGS AREA
ARCHITECTS
C2.0
UNIT 74 PARKING SITE
PLAN
April 8, 2022 - 100% CD 1818.700
RL
INDIAN HEALTH
SERVICE
WRSU OPTOMETRY
BUILDING & OFFICE
SPACE DESIGN
Fort Washakie, WY
75H70121F30009
CIVIL
Strike Consulting Group LLC 205 S. 3rd Street Lander, WY 82520 Phone: (307) 335-8466
STRUCTURAL
Turner Structural Eng.
3026 N Country Club Tucson, AZ 85716 Phone: (520) 323-3422
MECHANICAL
Adams & Associates 6422 E. Speedway Blvd., Unit 130 Tucson, AZ 85710 Phone: (520) 323-3858
ELECTRICAL
Adams & Associates 6422 E. Speedway Blvd.
Unit 130 Tucson, AZ 85710 Phone: (520) 323-3858
Attachment J03 - Optometry Remodel Combined Drawings Solicitation Number 75H701-23-R-00061
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
9.0' (TYP)
AutoCAD SHX Text NOTES: 1. ADA PARKING SHALL BE IN COMPLIANCE WITH THE MOST ADA PARKING SHALL BE IN COMPLIANCE WITH THE MOST CURRENT WYDOT ADA STANDARDS. 2. ALL ADA PARKING STALLS MUST HAVE PROPER SIGNS INSTALLED. ALL ADA PARKING STALLS MUST HAVE PROPER SIGNS INSTALLED. 3. ALL PARKING SPACE MARKINGS SHALL BE SOLID YELLOW 4" ALL PARKING SPACE MARKINGS SHALL BE SOLID YELLOW 4" LINES. 4. REPAVE ASPHALT THROUGH APPROACH AS NECESSARY. REPAVE ASPHALT THROUGH APPROACH AS NECESSARY. 5. REPLACE REMOVED CONCRETE GUTTER TO MATCH EXISTING. REPLACE REMOVED CONCRETE GUTTER TO MATCH EXISTING. 6. CONTOURS SHOWN IN PROPOSED GRADING ARE 0.1' MINOR AND CONTOURS SHOWN IN PROPOSED GRADING ARE 0.1' MINOR AND 0.5' MAJOR.
AutoCAD SHX Text
RUBBER WHEEL STOP (TYP) SEE DT1/C3.0
AutoCAD SHX Text
CONCRETE PAVING SEE DT2/C3.0
AutoCAD SHX Text
VISITOR PARKING SIGN (TYP) SEE DT3/C3.0
AutoCAD SHX Text
RETURN CURB SEE DT2/C2.0
AutoCAD SHX Text
REMOVE EXISTING FENCE BEYOND THIS POINT
AutoCAD SHX Text
SAW CUT AND REMOVE EXISTING CURB AND GUTTER
AutoCAD SHX Text
CONCRETE WALKWAY
AutoCAD SHX Text 1st STREET
AutoCAD SHX Text
UNIT 74
AutoCAD SHX Text
CONCRETE DRIVE
AutoCAD SHX Text
RETURN CURB
AutoCAD SHX Text
DT2
AutoCAD SHX Text C2.0
AutoCAD SHX Text
CONCRETE GUTTER
AutoCAD SHX Text
FLOW LINE TO MATCH EXISTING
AutoCAD SHX Text
GROUND SURFACE
AutoCAD SHX Text
"VAN-ACCESSIBLE" DESIGNATION WHERE APPLICABLE
AutoCAD SHX Text
DT1
AutoCAD SHX Text C2.0
AutoCAD SHX Text
ADA PARKING SIGN SEE DT1/C2.0
AutoCAD SHX Text A'
AutoCAD SHX Text A
AutoCAD SHX Text
(FLOWLINE)
AutoCAD SHX Text
(FLOWLINE)
AutoCAD SHX Text
A-A' SECTION VIEW N.T.S.
AutoCAD SHX Text
TYPICAL ASPHALT SECTION
AutoCAD SHX Text
FLOWLINE TO MATCH EXISTING
AutoCAD SHX Text
TYPICAL CONCRETE SECTION
AutoCAD SHX Text
UNDISTURBED SOIL
GRADING W CRUSHED BASE (8" MIN)
RUBBER WHEEL STOP
NOT TO SCALE
TYPICAL CONCRETE SECTION
NOT TO SCALE
VISITOR
PARKING
VISITOR PARKING SIGN
NOT TO SCALE
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
PREL
IM
IN
AR
Y - N
OT F
OR C
ONST
RUCTIO
N
FO
R R
EV
IEW
PURPOSE
S O
NLY
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
IHS PROJECT NO.
C
B
A
C
B
A
SHEET TITLE
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
E
H
N
ME
AR P
T
OF
T
C D
SU
S
A
E
TAE L &H
N
VI
SER
UMA
H
BILLINGS AREA
ARCHITECTS
C3.0
UNIT 76 PARKING SITE
PLAN
April 8, 2022 - 100% CD 1818.700
RL
INDIAN HEALTH
SERVICE
WRSU OPTOMETRY
BUILDING & OFFICE
SPACE DESIGN
Fort Washakie, WY
75H70121F30009
CIVIL
Strike Consulting Group LLC 205 S. 3rd Street Lander, WY 82520 Phone: (307) 335-8466
STRUCTURAL
Turner Structural Eng.
3026 N Country Club Tucson, AZ 85716 Phone: (520) 323-3422
MECHANICAL
Adams & Associates 6422 E. Speedway Blvd., Unit 130 Tucson, AZ 85710 Phone: (520) 323-3858
ELECTRICAL
Adams & Associates 6422 E. Speedway Blvd.
Unit 130 Tucson, AZ 85710 Phone: (520) 323-3858
Attachment J03 - Optometry Remodel Combined Drawings Solicitation Number 75H701-23-R-00061
AutoCAD SHX Text
DO NOT ENTER
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
9.0' (TYP)
AutoCAD SHX Text
DT1
AutoCAD SHX Text C3.0
AutoCAD SHX Text
12" LAG BOLT OR REBAR SPIKE (TYP)
AutoCAD SHX Text
SAW CUT AND REMOVE ASPHALT
AutoCAD SHX Text
SCARIFY AND RECOMPACT SUBGRADE
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
GRADING W CRUSHED BASE (8" MIN)
AutoCAD SHX Text
ASPHALT FLUSH WITH CONCRETE
AutoCAD SHX Text
DT2
AutoCAD SHX Text C3.0
AutoCAD SHX Text NOTES: 1. ADA PARKING SHALL BE IN COMPLIANCE WITH THE MOST ADA PARKING SHALL BE IN COMPLIANCE WITH THE MOST CURRENT WYDOT ADA STANDARDS. 2. ALL ADA PARKING STALLS MUST HAVE PROPER SIGNS INSTALLED. ALL ADA PARKING STALLS MUST HAVE PROPER SIGNS INSTALLED. 3. ALL PARKING SPACE MARKINGS SHALL BE SOLID YELLOW 4" ALL PARKING SPACE MARKINGS SHALL BE SOLID YELLOW 4" LINES.
AutoCAD SHX Text
RUBBER WHEEL STOP (TYP) SEE DT1/C3.0
AutoCAD SHX Text
CONCRETE PAVING SEE DT2/C3.0
AutoCAD SHX Text
VISITOR PARKING SIGN BEHIND EXISTING FENCE (TYP) SEE DT3/C3.0
AutoCAD SHX Text
CONCRETE WALKWAY
AutoCAD SHX Text
BLACK COAL DRIVE
AutoCAD SHX Text
BLACK COAL DRIVE
AutoCAD SHX Text
ADA PARKING SIGN SEE DT1/C2.0
AutoCAD SHX Text
GROUND SURFACE
AutoCAD SHX Text
DT3
AutoCAD SHX Text C3.0
UNIT 76
B. FORMED CONCRETE 1 1/2 INCHES
ACCORDANCE WITH ACI 318, AND NOT LESS THAN 48 BAR DIAMETERS.
5. ALL REINFORCING BARS, ANCHOR BOLTS, AND CONCRETE INSERTS SHALL
6. PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN CONCRETE
7. NO CONSTRUCTION JOINTS (OTHER THAN THOSE SHOWN ON DRAWINGS) SHALL
B. ALL REINFORCING IN CONCRETE SHALL BE CONTINUOUS OR LAPPED IN
A. ALL REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO
1/4" BULLNOSE AT SLAB JOINTS. CHAMFER CORNER ON VERTICAL ONLY.
BE SECURED IN POSITION PRIOR TO PLACING CONCRETE.
BEFORE PLACING CONCRETE. DO NOT CUT ANY REINFORCING WHICH MAY
CONFLICT. CONSULT ARCHITECT/ENGINEER OF SUCH CONFLICTS.
BE INSTALLED WITHOUT APPROVAL OF THE ARCHITECT/ENGINEER. PROVIDE
ASTM A-615 GRADE 60.
8. REINFORCING STEEL:
1. ALL CONCRETE SHALL CONFORM WITH ASTM C-94 AND ATTAIN THE
2. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE PROVISIONS FOR
3. CONCRETE FOOTINGS AND PADS MAY BE POURED AGAINST NEAT
4. MINIMUM CONCRETE COVER OVER REINFORCING BARS SHALL BE AS
A. ACI 301 - SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS
B. ACI 318 - BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE
EXCAVATIONS, PROVIDED PLAN DIMENSIONS ARE ADHERED TO.
A. CONCRETE POURED DIRECTLY AGAINST EARTH 3 INCHES
A. FOOTINGS, SLAB ON GRADE 3,000 PSI
FOLLOWING MINIMUM STRENGTHS AT 28 DAYS:
THE FOLLOWING LATEST ACI STANDARDS.
FOLLOWS:
III. CONCRETE:
B. ROOF DEAD LOAD: 20 PSF
A. ROOF LIVE LOAD: 46 PSF (SNOW)
D. EARTHQUAKE DESIGN DATA:
1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL
C. WIND LOAD: BASIC WIND SPEED = 115 MPH
BUILDING CODE, 2018 EDITION WITH LOCAL MODIFICATIONS.
2. DESIGN LOADS:
I. GENERAL:
S
WIND IMPORTANCE FACTOR:
SEISMIC DESIGN CATEGORY B
OCCUPANCY CATEGORY II
DS
I = 1.00W
EXPOSURE C
= 0.28 0.12=D1S
SITE CLASS: D
LATERAL SYSTEM:
LATERAL METHOD:
EQUIVALENT LATERAL
FORCE PROCEDURE
E.
5. ALL DETAILS SHOWN APPLY WHETHER SPECIFICALLY REFERENCED OR NOT.
6. ALL STRUCTURAL CALCULATIONS SUBMITTED TO THE ARCHITECT/ENGINEER
CONSTRUCTION. THE ARCHITECT/ENGINEER SHALL BE NOTIFIED OF ANY
3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING
FOR REVIEW, SHALL BEAR THE SEAL OF A PROFESSIONAL ENGINEER
(STRUCTURAL) REGISTERED IN THE STATE OF ARIZONA.
4. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON
DISCREPANCIES OR INCONSISTENCIES.
DRAWINGS.
WOOD SHEAR PANELS
LIGHT FRAME WALLS W/
SOIL PRESSURE: 1,500 PSF, NO SOILS REPORT
II. FOUNDATION AND EARTHWORK
FIXTURES, PIPING, AND CONDUIT INCLUDING SLEEVES, CONCRETE INSERTS,
ALL DIMENSIONS OF EXISTING CONSTRUCTION HAVE BEEN TAKEN FROM AS-BUILT
THREADED RODS AND HANGERS.
THIS PROJECT INVOLVES ADDITIONS AND ALTERATIONS TO EXISTING
CONFORM WITH EXISTING CONSTRUCTION IN ACCORDANCE WITH THE AS-BUILT
DRAWINGS. IF CONDITIONS ARE UNCOVERED WHICH DIFFER FROM WHAT IS
SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT
AND STRUCTURAL ENGINEER FOR RECOMMENDATIONS PRIOR TO PROCEEDING
DRAWINGS AND SITE SURVEY INFORMATION. THE CONTRACTOR IS RESPONSIBLE
FOR VERIFYING ALL DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK.
CONSTRUCTION, EVERY EFFORT HAS BEEN MADE TO DETAIL THE DRAWINGS TO
WITH THE WORK.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CUTTING OF ALL REQUIRED
OPENINGS THROUGH BUILDING FLOORS, WALLS, ROOFS, AND FOR THE
INSTALLATION OF WALL STRUCTURAL SUPPORT MEMBERS. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR THE COMPLETE INSTALLATION OF ALL EQUIPMENT,
ANY EXISTING CONSTRUCTION OCCURS.
THAT MAY BE REQUIRED TO INSURE THAT NO SETTLEMENT OR MOVEMENT OF
MAINTENANCE OF ALL SHORING AND BRACING OF EXISTING CONSTRUCTION
THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN, PLACEMENT, AND
THIS NOTE APPLIES TO ALL EXISTING BUILDING AREAS:
1.
2.
3.
4.
IV. CARPENTRY:
1. ALL FOOTINGS SHALL BE FOUNDED AT THE DEPTHS INDICATED ON CONSTRUCTION
DRAWINGS, OR 24 INCHES MINIMUM BELOW LOWEST ADJACENT GRADE.
2. EXTERIOR FINISHED GRADES SHALL SLOPE TO DRAIN AWAY FROM BUILDING WALLS
TO ELIMINATE WATER POCKETS ADJACENT TO BUILDING FOUNDATIONS.
3. PROVIDE 4" THICK GRANULAR BASE COURSE BELOW ALL SLABS ON GRADE UNLESS
NOTED OTHERWISE.
1. ROUGH CARPENTRY:
A. ALL LUMBER SHALL BE DOUGLAS FIR-LARCH OF THE FOLLOWING GRADE:
STUDS & BLOCKING. . . . . . . Fb = 900 PSI. . . . . . . E = 1,600,000 PSI
B. ROOF AND WALL SHEATHING SHALL BE APA RATED SHEATHING PLYWOOD
EXPOSURE I.
C. ALL NAILING SHALL CONFORM TO THE LATEST IBC TABLE NO. 2304.10.1
AND AS NOTED ON DRAWINGS.
D. ALL LUMBER SHALL BEAR THE STAMP OF AN APPROVED GRADING AGENCY.
2. GLU-LAM BEAMS:
A. ALL LAMINATED BEAMS SHALL CONFORM TO AITC 117 "STANDARD
SPECIFICATIONS FOR STRUCTURAL GLUED LAMINATED TIMBER"
B. PROVIDE GLU-LAM BEAMS OF AITC COMBINATION SYMBOL 24F-V4 UNLESS
NOTED OTHERWISE.
C. PROVIDE STANDARD CAMBER OF GLU-LAM BEAMS UNLESS NOTED
OTHERWISE ON DRAWINGS.
1/2" = 1'-0" TYPICAL UNLESS NOTED OTHERWISE
2 - #4 CONT.
1 - #4 CONT.
NOSE BAR
FIN. GRADE
TOOLED EDGE
8"
V
AR
IE
S 2'
-6 " M
AX
#4 AT 16" O.C.
1'-6"
GUARDRAIL, SEE
ARCH. DRAWINGS
8"
4" CONC. SLAB REINFORCED
W/ 6 x 6 - W1.4xW1.4 W.W.M
ON 4" GRANULAR BASE
COURSE
1 - #4 CONT.
30# FELT JOINT
1" TYP.
8"
SEE ARCH. DRWGS.
FOR SIZE & NUMBER
#4 NOSE BAR,
TYP.
#4 AT 16" O.C. EA. DIR.
IN CONCRETE CHEEK
WALL BEYOND, U.N.O.
SEE ARCH. FOR
EXTENTS OF CURB
VA
RI
ES
VARIES, SEE PLAN
#4 AT 16" O.C.
P 1/4" x 5" x 5" WITH
(4) - 1/2"Ø x 5" HSA L
3/16
3/16
3/4"=1'-0"
EXISTING
WOOD TRUSS
CEILING
WOOD BLOCKING
FOLDING DOOR
PER MFR.
2x4 AT 24" O.C. W/
SIMPSON "U" SERIES
JOIST HANGER EA END
2 x 6 CONT. BLOCKING
WITH 2 - #10 SCREWS
EA JOIST
3/4"=1'-0"
EXISTING TRUSS
EXISTING 2X STUD WALL
NEW GLB, SEE PLAN
SIMPSON A34
FRAMING ANCHOR
EA. STUD
EXISTING TRUSS
3/4"=1'-0"
NEW GLB, SEE PLAN
EXISTING 2X
STUD WALL
SIMPSON H2.5
FRAMING ANCHOR
EA. SIDE OF BEAM
DOUBLE 2x TOP
PLATE
2 - 2x6 STUDS
BELOW BEAM
BEARING
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
C
B
A
C
B
A
SHEET TITLE
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
PHOENIX AREA
R
VI
H
P
S
NI
D
C E
I
A
A N
HE TL H
SE
E
H
N M E
AR P
T
OF
T
C D
SU
S
A
E
TAE L &H
N
VI
S E R
UM
A
H
ARCHITECTS
S1.1
STANDARD STRUCTURAL
NOTES AND DETAILS
April 08, 2022 - 100% CD 1818.900
C.A.T.
INDIAN HEALTH
SERVICE
CIVIL
EEC
462 E Fort Lowell Road Tucson, AZ 85712 Phone: (520) 321-4625
STRUCTURAL
MECHANICAL
Adams & Associates 4067 E Grante Rd, Suite 200 Tucson, AZ 85712 Phone: (520) 323-3858
ELECTRICAL
M3 Engineering 2051 W Sunset Rd Tucson, AZ 85704 Phone: (520) 293-1488
Parker, AZ
IHS PROJECT NO.PH16CR07Q3
WRSU OPTOMETRY BUILDING &
OFFICE SPACE DESIGN
Turner Structural Eng.
2806 N Alvernon Way, Suite 400 Tucson, AZ 85712 Phone: (520) 323-3422
04/08/22
Attachment J03 - Optometry Remodel Combined Drawings Solicitation Number 75H701-23-R-00061
AutoCAD SHX Text
STANDARD STRUCTURAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text
CONCRETE RAMP
AutoCAD SHX Text
AutoCAD SHX Text
CONCRETE STAIR
AutoCAD SHX Text
AutoCAD SHX Text
FOLDING PARTITION SUPPORT
AutoCAD SHX Text
AutoCAD SHX Text
WALL SUPPORT BEAM
AutoCAD SHX Text
AutoCAD SHX Text
BEAM BEARING AT EXISTING WALL
AutoCAD SHX Text
PLATE
AutoCAD SHX Text
LINE
AutoCAD SHX Text
PLATE
AutoCAD SHX Text
LINE
AutoCAD SHX Text e
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text Z
AutoCAD SHX Text n
AutoCAD SHX Text I
AutoCAD SHX Text g
AutoCAD SHX Text i
AutoCAD SHX Text S
AutoCAD SHX Text d
AutoCAD SHX Text e
AutoCAD SHX Text e
AutoCAD SHX Text R
AutoCAD SHX Text a
AutoCAD SHX Text D
AutoCAD SHX Text t
AutoCAD SHX Text s
AutoCAD SHX Text i
AutoCAD SHX Text g
AutoCAD SHX Text e
AutoCAD SHX Text U.
AutoCAD SHX Text S.
AutoCAD SHX Text A.
AutoCAD SHX Text a
AutoCAD SHX Text l
AutoCAD SHX Text
AutoCAD SHX Text c
AutoCAD SHX Text t
AutoCAD SHX Text u
AutoCAD SHX Text r
AutoCAD SHX Text u
AutoCAD SHX Text e
AutoCAD SHX Text P
AutoCAD SHX Text r
AutoCAD SHX Text o
AutoCAD SHX Text f
AutoCAD SHX Text E
AutoCAD SHX Text x
AutoCAD SHX Text p
AutoCAD SHX Text i
AutoCAD SHX Text r
AutoCAD SHX Text e
AutoCAD SHX Text s
AutoCAD SHX Text 09/
AutoCAD SHX Text 30/
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HART
AutoCAD SHX Text
JAMES D.
AutoCAD SHX Text 27343
AutoCAD SHX Text t
AutoCAD SHX Text e
AutoCAD SHX Text t
AutoCAD SHX Text r
AutoCAD SHX Text r
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text d
AutoCAD SHX Text l
AutoCAD SHX Text a
AutoCAD SHX Text n
AutoCAD SHX Text o
AutoCAD SHX Text i
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text s
AutoCAD SHX Text s
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text O.
AutoCAD SHX Text n
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text g
AutoCAD SHX Text n
AutoCAD SHX Text i
AutoCAD SHX Text e
AutoCAD SHX Text r e
S1.1
S1.1
S1.1
S1.1
C.J.C.J.
DN
DN
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
C
B
A
C
B
A
SHEET TITLE
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
PHOENIX AREA
R
VI
H
P
S
NI
D
C E
I
A
A N
HE TL H
SE
E
H
N M E
AR P
T
OF
T
C D
SU
S
A
E
TAE L &H
N
VI
S E R
UM
A
H
ARCHITECTS
S1.2
BLDG 74 - FOUNDATION
AND FRAMING PLANS
1818.900
C.A.T.
INDIAN HEALTH
SERVICE
CIVIL
EEC
462 E Fort Lowell Road Tucson, AZ 85712 Phone: (520) 321-4625
STRUCTURAL
Turner Structural Eng.
MECHANICAL
Adams & Associates 4067 E Grante Rd, Suite 200 Tucson, AZ 85712 Phone: (520) 323-3858
ELECTRICAL
M3 Engineering 2051 W Sunset Rd Tucson, AZ 85704 Phone: (520) 293-1488
Parker, AZ
IHS PROJECT NO.PH16CR07Q3
WRSU OPTOMETRY BUILDING &
OFFICE SPACE DESIGN
N
0' 2' 4' 8'
1/4" = 1'-0"1 FOUNDATION PLAN
1/4" = 1'-0"2 ROOF FRAMING PLAN
1. EXISTING BUILDING.
2. EXISTING CONCRETE SLAB.
3. NEW CONCRETE SLAB, SEE ARCHITECTURAL.
4. INFILL EXISTING OPENING. SEE ARCHITECTURAL DRAWINGS.
EX
IS
TI
NG
IN
TE
RM
ED
IA
TE
B
EA
M
EX
IS
TI
NG
IN
TE
RM
ED
IA
TE
B
EA
M
EX
IS
TI
NG
R
ID
GE
EXISTING WOOD
BRACE AT 4'-10" O.C.
EXISTING WOOD
BRACE AT 4'-10" O.C.
EX
IS
TI
NG
W
OO
D
TR
US
SE
S
AT
4"
O .C
April 08, 2022 - 100% CD
Turner Structural Eng.
2806 N Alvernon Way, Suite 400 Tucson, AZ 85712 Phone: (520) 323-3422
04/08/22
Attachment J03 - Optometry Remodel Combined Drawings Solicitation Number 75H701-23-R-00061
AutoCAD SHX Text
FOUNDATION KEYNOTES:
AutoCAD SHX Text
FRAMING KEYNOTES:
AutoCAD SHX Text e
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text Z
AutoCAD SHX Text n
AutoCAD SHX Text I
AutoCAD SHX Text g
AutoCAD SHX Text i
AutoCAD SHX Text S
AutoCAD SHX Text d
AutoCAD SHX Text e
AutoCAD SHX Text e
AutoCAD SHX Text R
AutoCAD SHX Text a
AutoCAD SHX Text D
AutoCAD SHX Text t
AutoCAD SHX Text s
AutoCAD SHX Text i
AutoCAD SHX Text g
AutoCAD SHX Text e
AutoCAD SHX Text U.
AutoCAD SHX Text S.
AutoCAD SHX Text A.
AutoCAD SHX Text a
AutoCAD SHX Text l
AutoCAD SHX Text
AutoCAD SHX Text c
AutoCAD SHX Text t
AutoCAD SHX Text u
AutoCAD SHX Text r
AutoCAD SHX Text u
AutoCAD SHX Text e
AutoCAD SHX Text P
AutoCAD SHX Text r
AutoCAD SHX Text o
AutoCAD SHX Text f
AutoCAD SHX Text E
AutoCAD SHX Text x
AutoCAD SHX Text p
AutoCAD SHX Text i
AutoCAD SHX Text r
AutoCAD SHX Text e
AutoCAD SHX Text s
AutoCAD SHX Text 09/
AutoCAD SHX Text 30/
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HART
AutoCAD SHX Text
JAMES D.
AutoCAD SHX Text 27343
AutoCAD SHX Text t
AutoCAD SHX Text e
AutoCAD SHX Text t
AutoCAD SHX Text r
AutoCAD SHX Text r
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text d
AutoCAD SHX Text l
AutoCAD SHX Text a
AutoCAD SHX Text n
AutoCAD SHX Text o
AutoCAD SHX Text i
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text s
AutoCAD SHX Text s
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text O.
AutoCAD SHX Text n
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text g
AutoCAD SHX Text n
AutoCAD SHX Text i
AutoCAD SHX Text e
AutoCAD SHX Text r
EXISTING WOOD TRUSSES AT 24" O.C. (HIGH)EXISTING WOOD TRUSSES AT 24" O.C. (LOW)
NEW GLB 5 1/8" x 12"
NE
W
G
LB
/8 " x
2"
S1.1
S1.1
S1.1
TY
P.
S1.1
S1.1
S1.1
S1.1
DN
DN
C.
J.
C.
J.
C.
J.
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
C
B
A
C
B
A
SHEET TITLE
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
PHOENIX AREA
R
VI
H
P
S
NI
D
C E
I
A
A N
HE TL H
SE
E
H
N M E
AR P
T
OF
T
C D
SU
S
A
E
TAE L &H
N
VI
S E R
UM
A
H
ARCHITECTS
S1.3
BLDG 76 - FOUNDATION
AND FRAMING PLANS
1818.900
C.A.T.
INDIAN HEALTH
SERVICE
CIVIL
EEC
462 E Fort Lowell Road Tucson, AZ 85712 Phone: (520) 321-4625
STRUCTURAL
MECHANICAL
Adams & Associates 4067 E Grante Rd, Suite 200 Tucson, AZ 85712 Phone: (520) 323-3858
ELECTRICAL
M3 Engineering 2051 W Sunset Rd Tucson, AZ 85704 Phone: (520) 293-1488
Parker, AZ
IHS PROJECT NO.PH16CR07Q3
WRSU OPTOMETRY BUILDING &
OFFICE SPACE DESIGN
N
0' 2' 4' 8'
1/4" = 1'-0"1 FOUNDATION PLAN
1/4" = 1'-0"2 ROOF FRAMING PLAN
1. EXISTING BUILDING.
2. EXISTING CONCRETE SLAB.
3. NEW CONCRETE SLAB, SEE ARCHITECTURAL.
1. INDICATES FOLDING PARTITION SUPPORTED FROM
ROOF FRAMING. SEE ARCHITECTURAL DRAWINGS.
April 08, 2022 - 100% CD
Turner Structural Eng.
2806 N Alvernon Way, Suite 400 Tucson, AZ 85712 Phone: (520) 323-3422
04/08/22
Attachment J03 - Optometry Remodel Combined Drawings Solicitation Number 75H701-23-R-00061
AutoCAD SHX Text
FOUNDATION KEYNOTES:
AutoCAD SHX Text
FRAMING KEYNOTES:
AutoCAD SHX Text e
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text Z
AutoCAD SHX Text n
AutoCAD SHX Text I
AutoCAD SHX Text g
AutoCAD SHX Text i
AutoCAD SHX Text S
AutoCAD SHX Text d
AutoCAD SHX Text e
AutoCAD SHX Text e
AutoCAD SHX Text R
AutoCAD SHX Text a
AutoCAD SHX Text D
AutoCAD SHX Text t
AutoCAD SHX Text s
AutoCAD SHX Text i
AutoCAD SHX Text g
AutoCAD SHX Text e
AutoCAD SHX Text U.
AutoCAD SHX Text S.
AutoCAD SHX Text A.
AutoCAD SHX Text a
AutoCAD SHX Text l
AutoCAD SHX Text
AutoCAD SHX Text c
AutoCAD SHX Text t
AutoCAD SHX Text u
AutoCAD SHX Text r
AutoCAD SHX Text u
AutoCAD SHX Text e
AutoCAD SHX Text P
AutoCAD SHX Text r
AutoCAD SHX Text o
AutoCAD SHX Text f
AutoCAD SHX Text E
AutoCAD SHX Text x
AutoCAD SHX Text p
AutoCAD SHX Text i
AutoCAD SHX Text r
AutoCAD SHX Text e
AutoCAD SHX Text s
AutoCAD SHX Text 09/
AutoCAD SHX Text 30/
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HART
AutoCAD SHX Text
JAMES D.
AutoCAD SHX Text 27343
AutoCAD SHX Text t
AutoCAD SHX Text e
AutoCAD SHX Text t
AutoCAD SHX Text r
AutoCAD SHX Text r
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text d
AutoCAD SHX Text l
AutoCAD SHX Text a
AutoCAD SHX Text n
AutoCAD SHX Text o
AutoCAD SHX Text i
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text s
AutoCAD SHX Text s
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text O.
AutoCAD SHX Text n
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text g
AutoCAD SHX Text n
AutoCAD SHX Text i
AutoCAD SHX Text e
AutoCAD SHX Text r
EMERGENCY EGRESS
EXITING ROUTE STARTING POINT
EXITING ROUTE
PROVIDE PORTABLE FIRE EXTINGUISHER UNDER
KITCHEN SINK, CFCI, MAX 75' TRAVEL DISTANCE
PER 2015 IBC TABLE 906.3 (1), REF SPECS
FE
EXIT
FIRE / EXITING LEGEND
1 HR RATED WALL
(E) ENTRY
EXTERIOR(E) CONFERENCE ROOM
(E) WAITING AREA
(E) CORRIDOR
115' TRAVEL 96' TRAVEL
EXIT
(E) WALL
PROJECT INFORMATION
Scope of work: RENOVATE APPROX. 750 SQ. FT. OF EXISTING OFFICE SPACES WITHIN FORT WASHAKIE
HEALTH CENTER. THREE NEW OFFICE SPACES TO BE OCCUPIED BY HIM DEPARTMENT
Existing Building Description
Number of Stories:
Construction Type:
Fire Protection System:
Occupancy Type:
Use:
1 (Unchanged)
Type: VB
Fully Sprinklered (Unchanged)
Business & Healthcare(Unchanged)
Unchanged
Building Area:
Level 1: Unchanged
Corridors:
Exit Corridors : Walls and Doors: Unchanged
Roof:
Existing to remain unchanged (Unchanged) -
Plumbing Fixtures:
UnchangedWater Closet / Lavatories:
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
E
H
N M
E
A R
P
T O F
T
C D
SU
S
A
E
TAE L
&H
N V I
S E R
U M A
H
BILLINGS AREA
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S i g n e d . . .
CE
R T
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2022
ARCHITECTS
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
IHS PROJECT NO.
C
B
A
C
B
A
SHEET TITLE
A1.0
HIM DEPARTMENT -
CODE REVIEW
May 5, 2022 - 100% CD 1818.700
CEM
INDIAN HEALTH
SERVICE
WRSU OPTOMETRY
BUILDING & OFFICE
SPACE DESIGN
Fort Washakie, WY
75H70121F30009
04/
/2
CIVIL
Strike Consulting Group LLC
205 S. 3rd Street
Lander, WY 82520
Phone: (307) 335-8466
STRUCTURAL
Turner Structural Eng.
2806 N Alvernon Way, Suite 400
Tucson, AZ 85712
Phone: (520) 323-3422
MECHANICAL
Adams & Associates
6422 E. Speedway Blvd., Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
ELECTRICAL
Adams & Associates
6422 E. Speedway Blvd.
Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
APPLICABLE CODES
INTERNATIONAL BUILDING CODE 2021 EDITION
INTERNATIONAL PLUMBING CODE 2021 EDITION
INTERNATIONAL MECHANICAL CODE 2021 EDITION
INTERNATIONAL FIRE CODE 2021 EDITION
NATIONAL ELECTRIC CODE 2020 EDITION
SPRINKLER CODE 2022 NFPA 13
INTERNATIONAL ENERGY CONSERVATION CODE 2021 EDITION
ANSI A117.1 ACCESIBILITY CODE 2017 EDITION
* AND ALL OTHER CODES AND ORDINANCES AS ADOPTED BY THE GOVERNING AGENCIES HAVING
JURISDICTION
N
FIRE PROTECTION NOTES
1. FINAL FIRE SPRINKLER DESIGN TO BE PROVIDED BY THE CONTRACTOR AS A SEPARATE
SUBMITTAL PER FIRE PROTECTION DRAWINGS AND SPECIFICATIONS
1/4" = 1'-0"1
HIM DEPT - FLOOR PLAN
PATIENT REGISTRATION
MANAGER / BENEF
COORD
CODERS
V
IF
9"
(E) ENTRY
A1.31
EXTERIOR
21'-5 1/2" 23'-8 1/2" 12'-0" 6'-0"
5' -1
1/
2" 5'
-1
1/ 2"
(E) CONFERENCE ROOM
(E) RESTROOM
LINE INDICATES ALIGNMENT OF
END OF NEW WALLS WITH
(E) RESTROOM WALL
(E) RESTROOM
(E) WAITING AREA
(E) CORRIDOR
(E) AUDIOLOGY(E) FIELD NURSE(E) PHN DIRECTOR(E) WAITING AREA
216 213
D1
D1
D1
2'-0" 2'-0" 2'-0"
225225
225225
225225
A. DIMENSIONS ARE TO FACE OF STUD, U.N.O.
B. GENERAL CONTRACTOR TO CONFIRM ALL EXISTING CONDITIONS PRIOR TO START OF
CONSTRUCTION.
FLOOR PLAN GENERAL NOTES
3'-8 1/2"
005005
N
1/4" = 1'-0"1
HIM DEPT - FLOOR PLAN
0' 2' 4' 8'
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
E
H
N M
E
A R
P
T O F
T
C D
SU
S
A
E
TAE L
&H
N V I
S E R
U M A
H
BILLINGS AREA
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S i g n e d . . .
CE
R T
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2022
ARCHITECTS
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
IHS PROJECT NO.
C
B
A
C
B
A
SHEET TITLE
A1.1
HIM DEPARTMENT -
FLOOR PLAN
May 5, 2022 - 100% CD 1818.700
RL
INDIAN HEALTH
SERVICE
WRSU OPTOMETRY
BUILDING & OFFICE
SPACE DESIGN
Fort Washakie, WY
75H70121F30009
04/
/2
CIVIL
Strike Consulting Group LLC
205 S. 3rd Street
Lander, WY 82520
Phone: (307) 335-8466
STRUCTURAL
Turner Structural Eng.
2806 N Alvernon Way, Suite 400
Tucson, AZ 85712
Phone: (520) 323-3422
MECHANICAL
Adams & Associates
6422 E. Speedway Blvd., Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
ELECTRICAL
Adams & Associates
6422 E. Speedway Blvd.
Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
001 REMOVE WALL
005 REMOVE DOOR AND FRAME
006 REMOVE PLUMBING FIXUTURE, SEE PLUMB
010 REMOVE CASEWORK
213 FILL IN WALL, MATCH EXISTING FINSIH
216 (E) WALL
217 NEW TRANSACTION COUNTER
224 CAP END OF WALL AND APPLY CORNER GUARDS TO MATCH EXISTING CLINIC
225 NEW FLOORING, SEE ROOM SCHEDULE
226 CONFIRM WALL LOCATION WITH (E) WINDOW
KEYNOTES
N
0' 2' 4' 8'
1/4" = 1'-0"2
HIM DEPT - DEMO FLOOR PLAN
WALL MOUNTED LIGHT SUPPLY GRILLE
RETURN GRILLE
EXHAUST GRILLE
GWB
RCP LEGEND
RECESSED LIGHT
DECORATIVE LIGHT
2' STRIP LIGHT
SIDEWALL SUPPLY GRILLE
TUBULAR SKYLIGHT
2x2 LIGHT FIXTURE
2x4 LIGHT FIXTURE
2X4 ACOUSTIC CEILING TILE
(2) SCREWS @ 16" O.C. TO
STRUC. ABOVE
2X4 WD STUDS @ 16" O.C.,
TYP
(2) SCREWS @ 16" O.C.
GWB CLG - REFER TO RCP
(E) STRUCTURE ABOVE
GWB CORNER BEAD
GWB - REFER TO ROOM
FINISH SCHEDULE
CLG - REFER TO RCP
CARRY GWB TO 6" ABOVE
CLG AS OCCURS
9' - 0"
(E) VIF
8' - 0"
9' - 0"9' - 0"9' - 0"
5' -7
/2
5'
-7
/2
304304
304304
310310 310310 310310
2' -1
0" 2'
-1 0"
2' -1
0" 2'
-1 0"
3' - 0" 4' - 0" 3' - 0"
10' - 0"
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
DIVISION OF FACILITIES ENGINEERING
E
H
N M
E
A R
P
T O F
T
C D
SU
S
A
E
TAE L
&H
N V I
S E R
U M A
H
BILLINGS AREA
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S i g n e d . . .
CE
R T
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2022
ARCHITECTS
261 North Court Avenue
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
DRAWN BY:
CONSULTANTS
Tucson, Arizona 85701
CHECKED BY:
CAD DWG FILE:
PROJECT NO:
ISSUE:
REVIEWED:
DFE ENGINEER/PROJECT MANAGER
APPROVED:
DFE BRANCH CHIEF
CONCURRENCE:
DFE CHIEF
DATE
DATE
DATE
REV DATE DESCRIPTION
IHS PROJECT NO.
C
B
A
C
B
A
SHEET TITLE
A1.2
HIM DEPARTMENT -
REFLECTED CEILING PLAN
May 5, 2022 - 100% CD 1818.700
RL
INDIAN HEALTH
SERVICE
WRSU OPTOMETRY
BUILDING & OFFICE
SPACE DESIGN
Fort Washakie, WY
75H70121F30009
04/
/2
CIVIL
Strike Consulting Group LLC
205 S. 3rd Street
Lander, WY 82520
Phone: (307) 335-8466
STRUCTURAL
Turner Structural Eng.
2806 N Alvernon Way, Suite 400
Tucson, AZ 85712
Phone: (520) 323-3422
MECHANICAL
Adams & Associates
6422 E. Speedway Blvd., Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
ELECTRICAL
Adams & Associates
6422 E. Speedway Blvd.
Unit 130
Tucson, AZ 85710
Phone: (520) 323-3858
N
0' 2' 4' 8'
1. SEE FLOOR PLAN FOR PARTITION TYPES.
2. COORDINATE CEILING PLANS WITH MECHANICAL, FIRE
PROTECTION AND ELECTRICAL PLANS.
3. ALL GWB CEILINGS AND SOFFITS SHALL BE TEXTURED AND
PAINTED.
4. ACCESS PANELS IN FIRE RATED CEILINGS SHALL MATCH THE
FIRE RATING OF THE CEILING.
5. CENTER LIGHT FIXTURES IN CEILING, U.N.O.
GENERAL NOTES
302 NEW DROPPED GYPSUM SOFFIT
304 (E) CEILING TO REMAIN
310 NEW ACOUSTIC CEILING TILE
1 1/2" = 1'-0"2
GWB SOFFIT
KEYNOTES
1/4" = 1'-0"1
HIM DEPARTMENT RCP
A. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS AND EXTENT OF
SOFFITS
B. SEE PLANS AND INTERIOR ELEVATIONS FOR LOCATIONS AND EXTENTS OF VARIOUS
FINISH MATERIALS
FINISH SCHEDULE GENERAL NOTES
ACT ACOUSTIC CEILING TILE
CPT CARPET TILE
CONC CONCRETE
CLR CLEAR SEALER
FF FACTORY FINISH
FRP FIBERGLASS REINFORCED PANEL
GWB GYPSUM WALL BOARD
HM HOLLOW METAL
HW HOLLOW WOOD
MGWB MOISTURE RESISTANT
GYPSUM WALL BOARD
ABBREVIATIONS
P PAINT
PCT PORCELAIN TILE
RB RUBBER BASE
SGL SAFETY GLASS
SCW SOLID CORE WOOD
TB COVED TILE BASE
VCT VINYL COMPOSITION TILE
WD WOOD
MATERIAL TYPE/COLOR APPLICATION
MATERIALS & FINISHES LEGEND
CARPET TILE
CPT-1 SEE SPECS 24"X24"
CERAMIC TILE
CT-1 DALTILE/LINEAR 4"X12" WALL TILE
PORCELAIN TILE
PCT-1 DALTILE/NEOSPEC 24" x 24" FLOOR TILE
FIBER CEMENT
FC-1 DUNN…