Attachment (A) Statement of Work.pdf

PDF 309 KB Posted

Attached to
Twinax Cables for Data Transmission in Cryogenic Temperatures of DUNE
Solicitation number
RFQ_455376
Issued by

About this file

This Statement of Work from Brookhaven National Laboratory (BNL) outlines requirements for twinax cables needed for the Deep Underground Neutrino Experiment (DUNE) project. The document specifies the procurement of two types of specialized cables designed for cryogenic temperature operations at 77K.

The required cables must use THV (Tetrafluoroethylene, Hexafluoropropylene, Vinylidene Flouride) material for cable extrusion, which BNL testing has determined is the only acceptable material for the extreme temperature conditions. The order quantities are precisely defined: 1,750 pieces of 22-meter cables (part number HDR-223199-02-ECDP) and 2,200 pieces of 27-meter cables (part number HDR-227794-03-ECDP), to be procured in that specific order. The document is dated October 18, 2024.

View the file

Other files

File Type Posted
RFQ No. 455376.pdf PDF
Enclosure (4) W-9 Form.pdf PDF
Enclosure (3) Vendor ACH Authorization Form.pdf PDF
Attachment (B) BNL-QA-101.pdf PDF
Enclosure (2) Pricing Sheet 455376.docx DOCX document
Enclosure (1) Draft Contract 455376.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P.O. Box 5000 Upton, NY 11973-5000 managed by Brookhaven Science Associates for the U.S. Department of Energy

Subject: Statement of Work for Twinax Cables for Data Transmission in Cryogenic Temperatures of DUNE

Background:

Brookhaven National Labs (BNL) requires the purchase and delivery of twinax cables for data transmission in cryogenic temperatures associated with the DUNE (Deep Underground Neutrino Experiment) project. These cables are required to utilize THV (Tetrafluoroethylene, Hexafluoropropylene, Vinylidene Flouride) material for cable extrusion in the construction of these cables. Extensive tests carried out by BNL have shown that only this type of material is acceptable given the cryogenic temperature utilized (77K).

Schedule:

Two types of cables will be procured in the order stated in the contract:

1) 1,750 pieces of 22 m cables with part number of HDR-223199-02-ECDP

2) 2,200 pieces of 27 m cables with part number of HDR-227794-03-ECDP.

Signature: ___ ___Hucheng Chen___________ Of Requestor 10/18/2024

File details come from the government source that posted it. Updated .