This is a Scope of Services document for West Basin Municipal Water District, a California-based municipal water district, soliciting fixed unit rate proposals for on-call pump and motor mechanical and electrical repair, rebuild, and replacement services. The services will support West Basin's recycled water facilities and pumping stations across eight locations in the South Bay region of Los Angeles, including the Hyperion Secondary Effluent Pump Station, Edward C. Little Water Recycling Facility, Chevron Nitrification Treatment Plant, Torrance Refinery Water Recycling Plant, JMM Carson Regional Water Recycling Plant, and three booster pump stations. The anticipated agreement period is two years beginning October 2026, with an initial one-year term and a potential one-year extension. Services will be provided on an as-needed basis with emergency response requirements of one hour during business hours and twelve hours outside business hours. Contractors must submit written quotes within five business days of each service request and provide comprehensive documentation including before-and-after photographs, failure analysis reports, and functionality reports within one week of completion.
The contract carries a total not-to-exceed amount of $1,000,000, with pricing based on actual costs plus a maximum ten percent markup for contractor parts and five percent markup for subcontractor costs. Contractors must provide pick-up and return delivery services, on-site removal and reinstallation, and post-installation pump performance testing. All equipment repairs require OEM parts unless otherwise approved, and contractors must provide a minimum eighteen-month warranty on all equipment, parts, labor, and materials. Qualified contractors must demonstrate a minimum of five years of experience in electric motor repair for units ranging from 1.5 to 800 horsepower, maintain valid California Department of Industrial Relations Public Works Contractor Registration, provide a minimum of five references, and offer proof of a local repair facility available for inspection. ISO 9001 certification is recommended but not required.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Exhibit A – On-Call Pump and Motor Repairs, Rebuilds, and Replacements
Detailed Scope of Services
Project Description:
West Basin Municipal Water District (West Basin), invites submittal of fixed unit rate proposals in accordance with this Request for Proposal document to provide pump and motor mechanical and electrical repair, rebuild, and replacement services on an “as needed” basis for up to a two (2) year agreement period anticipated to begin October 2026 for a total not to exceed amount of $1,000,000.
Facilities listed below include various water treatment facilities that produce recycled water as well as pumping stations to provide recycled water to roughly 100 miles of purple pipeline for distribution to customer sites located throughout the South Bay region of Los Angeles. Motor and pump repairs, rebuilds, and replacements may be requested from any/all facilities.
Project Locations:
West Basin’s Recycled Water Facilities includes but is not limited to the following facilities:
• Hyperion Secondary Effluent Pump Station (HSEPS) o 12000 Vista Del Mar, Playa Del Rey, CA 90293
• Edward C. Little Water Recycling Facility (ECLWRF) o 1935 S. Hughes Way, El Segundo, CA, 90245
• Chevron Nitrification Treatment Plant (CNTP) o 1617 E El Segundo Blvd, El Segundo, CA 90245
• Torrance Refinery Water Recycling Plant (TRWRP) o 3700 W 190th St, Torrance, CA 90504
• JMM Carson Regional Water Recycling Plant (JMMCRWRP) o 21029 S Wilmington Ave, Carson, CA 90810
• Dominguez Booster Pump Station (DBPS) o 1364 E Victoria St, Carson, CA 90746
• Torrance Booster Pump Station (TBPS) o 5128 Del Amo Blvd, Torrance, CA 90503
• Lago Seco Booster Pump Station (LSBPS) o 23877 Ladeene Ave, Torrance, CA 90505
Scope of Services:
This Scope of Services is intended to support the solicitation of proposals for up to a two (2) year agreement covering repair, replacement, and servicing of West Basin’s pumps and motors. If applicable, a Prime pump contractor shall partner with a local motor subcontractor(s) for this work.
Upon written (e-mail) approval from West Basin’s Project Manager (PM), Contractor(s) will perform the requested work on as-needed basis. The PM will discuss with Contractor(s) the particulars of a given equipment repair project, the cost and not-to-exceed price, and the appropriate level of effort. Urgent or emergency work may be authorized on a time and materials basis with appropriate proof of time and submitted receipts.
Once written approval is given by the PM, the selected Contractor will travel to the appropriate West Basin location, pick-up and/or remove the designated equipment in need of repair, and proceed with the agreed-upon repair, rebuild, or replacement task(s). Contractor(s) shall be responsible for disconnecting, removing, and palletizing (if feasible) the designated equipment, as well as the re-installation of the repaired and/or replaced equipment. Contractor(s) must be able to provide on-site pick-up and/or removal service (e.g. crane service) and subsequent return delivery service plus disconnection, removal, and reinstallation/reconnection of repaired equipment to any of West Basin’s wastewater treatment facilities and/or other equipment locations.
To verify pump efficiency, a post‐installation pump test may be required as part of the post-overhaul pump commissioning process. The selected Contractor(s) must be capable of measuring and recording pump operational parameters after equipment reinstallation, such as pump flow capacity, total head, discharge pressure, and kW input to motor. Pump performance criteria, such as system flow and pressure requirements, may also be required by West Basin during a post-installation pump test verification.
Non-emergency work will be scheduled in advance. Contractor(s) shall be able to meet the emergency response times described below:
During West Basin business hours (7:30am – 5:00pm, M-F)
• Respond to request for services within 1 hours from receipt of notification.
• For onsite required support: dispatch to site within 4 hours from receipt of notification.
Outside of West Basin business hours, holidays, and weekends
• For onsite required support: respond to site within 12 hours from receipt of notification.
• The Contractor’s proposal should describe their approach for responding to unscheduled emergencies and after-hours support response.
West Basin’s e-mail approval authorization(s) shall convey a separate and discrete billing task order number which is to be referenced on the Contractor’s associated invoice. Note: West Basin reserves the right to send staff to Contractor's facility in order to witness final inspection/test of the repaired equipment prior to return shipment to West Basin. Contractor(s) services and responsibilities shall include and be in accordance with Scope of Services established below. The selected contractor(s) shall be capable of providing the following services:
1. Must be capable of machining and/or fabricating parts if required.
2. For pump repair projects:
a. Repair or replacement of the pump bowls/volutes and/or impellers.
b. Machine work (e.g., facing, pit, and hole filling, replacing wear rings) to return pump bowl(s) or impeller(s) to original condition (or better).
c. Trimming of impellers
i. Impellers shall be at the trim needed to optimize the pump performance. The design should be such that at design load the motor will not be loaded beyond the nameplate rating and at no place on the pump curve shall the loading exceed the service factor.
d. Addition or removal of pump stage(s)
e. Post-installation pump performance testing services, including measurement or verification of:
i. Individual pump flow capacity
ii. Total head
iii. Discharge pressure
iv. kW input to motor
3. The following are the different types of motorized equipment West Basin uses and that the selected contractor may be asked to provide repair and/or replacement services for:
• Centrifugal pumps
• Vertical turbine pumps
• Horizontal split case pumps
• Trash pumps
• Multi-stage pumps
• Positive displacement pumps
• Lobe pumps
• Gear pumps
• Progressive cavity pumps
• Piston pumps
• Blowers
• Compressors
• Gearboxes
• Mixers
• Conveyor systems (Screw & Belt types)
• Grinders (i.e. Muffin Monsters)
• Submersible pumps
• Ventilation fans
3. Below is a list of manufacturers that are commonly used throughout West Basin facilities, but may not be all inclusive. Contractor(s) may be asked to provide like-for-like replacements, service, support, repair labor, and/or OEM parts. Exhibit “B” includes additional examples of critical equipment installed at West Basin’s treatment facilities:
• Fairbanks Morse
• Flo-way
• Moyno
• Allweiler
• ABS
• Peabody
• Vaughn
• Leeson
• Wemco
• Gorman-Rupp
• Aurora
• Peerless
• Paco
• Myers
• Netzxch
• Monoflo
• Seepex
• Gould
• Aerzen
• SEW Eurodrive
• Clearstream
• Johnston
• Emerson
• US Motors
• General Electric
• Teco
• GE
• Marathon
• Nidec
• US Electric
• Emerson
• WEG
• Baldor
• Reliance
• Siemens
• Sew
• Alconza
Project Schedule:
All services to be provided on an “as needed basis” as requested by West Basin throughout the duration of the anticipated two (2) year agreement, consisting of an initial 1-year term (anticipated to begin October 2026) and a potential one (1) year extension, to be determined by West Basin.
Contract Cost:
West Basin may accept and incorporate the submitted Price Proposal as part of the award/agreement process without further negotiation or, alternatively, may use it as the basis for negotiations. Parts for the Contractor(s) and its subcontractor(s) are to be paid on actual costs plus a maximum of 10% markup. Contractor(s) and its subcontractor(s) shall provide all properly signed receipts upon request of the PM, or his/her designee. Subcontractor(s) total costs including the 10% markup on subcontractor(s) parts will be paid plus a maximum of 5% markup.
Assumptions & Applicable Specifications:
1. Contractor(s) must provide a written quote to the PM with particulars of a given equipment repair, replacement, or servicing project, including the cost and not-to-exceed price, and the appropriate level of effort within five (5) business days.
2. For each piece of equipment/repair, contractor must provide a written statement of work, including list of materials, in-shop/field labor, and total cost estimate.
3. Documentation shall include pictures before and after repairs and a description of repairs performed.
4. Report shall include “as-found” conditions and corrective repairs performed.
5. Contractor must have the capability to provide functionality report within one week after repair is complete related the following:
• Pressure testing
• Head Flow profile verification.
• Laser alignments after installation.
• Vibration test (in shop and installed)
• Insulation Resistance (IR)
• Polarization Index (PI)
• Winding Resistance
• Bearing Insulation Resistance
• Shaft Total Indicated Run Out (TIR)
• Inspection of Bearing Journals and
Housing (ED)
• Stator Visual Inspection
• Rotor Shaft Visual Inspection
• Clean Bake Dry and Varnish
• Surge Test
• Rotor Balance
• Core Loss
• Broken Rotor Bar Checks
• No Load Run Test with Vibration
Measurements
6. Contractor(s) shall provide pick-up and return delivery as part of its service plus removal and reinstallation at West Basin locations.
7. Contractor(s) shall lock-out / tag-out related electrical equipment.
8. Contractor(s) shall perform failure analysis and associated report generation for submittal within one week after repair is complete
9. Contractor(s) shall have the experience, knowledge, equipment, tools, and manpower to accomplish the above tasks including but not limited to all necessary cleaning, inspecting, repairing, machining, welding, and performance testing.
10. Contractor(s) shall provide a minimum of an eighteen (18) month warranty on all equipment, parts, labor, material, removal, and reinstallation.
11. Contractor(s) shall restore project site to a clean and safe condition to the satisfaction of the PM upon completion of the project.
12. Contractor(s) shall have a representative present following a repair/replacement to witness any related verification/certification tests (e.g. rotation check, vibration field test).
13. Contractor(s) may be required to drain and replace lubricating oil.
14. Contractor(s) must be able to provide emergency response within a 24-hour notice for expediting option.
15. Contractor(s) shall be able to prove capability in terms of:
a) A local facility available for tour (or through video or photos with physical address) with West Basin’s representatives plus optional interview prior to award.
b) Must be able to provide minimum of five (5) references, including company or agency information.
c) Contractor(s) and its subcontractor(s), if any, must have a minimum of 5 years of experience providing electric motor repair services for units ranging in size from 1.5 horsepower (Hp) to 800 Hp.
d) Contractor(s) and its subcontractors(s), if any, must submit proof of a valid and active state of California Department of Industrial Relations Public Works Contractor Registration pursuant to Labor Code 1725.5. Pending registrations will not be accepted.
16. All repairs shall receive OEM parts only unless otherwise approved by authorized maintenance representatives.
17. ISO 9001 Certification is recommended, but not required.
| Exhibit A – On-Call Pump and Motor Repairs, Rebuilds, and Replacements |
| Detailed Scope of Services |