This document is an Attachment 5 titled "Bullet-Resistant Panel Feet Examples" that provides details on the required feet or base options for the bullet-resistant panels to be provided under the "Joint Recruiting Facilities Program Bullet-Resisting Panels" solicitation.

The key details include:

  • The panels must have the flexibility to be used up against or adjacent to desks, walls, or in open areas
  • Each foot is to be individually inserted/applied to the panel as necessary
  • A triangle foot option is presented as the preferred option for stability, with other options allowed for approval
  • The feet must match the trim color specified
  • Additional feet beyond those shown may be required, with varying mounting width based on panel length
  • The panels are required to be 2.5 inches thick with a 0.5 inch variance
  • The solicitation is for the manufacture, shipping, delivery, and installation of the bullet-resistant panels for approximately 170 recruiting facilities across CONUS and OCONUS

The overall requirements for the bullet-resistant panels, including measurements, colors, and other specifications, are to be followed per the Statement of Work.

View the file

Other files for this federal contract opportunity

Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bullet-Resistant Panel Feet Example

Foot: Triangle Option – Aerial

View

Foot: Triangle Option – Side View

Attachment 5

The freestanding panels (CLIN 0001 thru 0008) MUST have the flexibility to be used up against or adjacent to desks, walls or in open areas. Each foot to be individually inserted / applied to the panel as necessary.

If a triangle option is necessary for stability, the easiest attachment methods shall be presented to the Government for review, selection and approval.

Other options may be presented for approval.

Left or Right Triangle Option –

Front View Other options may be presented for approval.

Color of feet to match trim color specified.

Color of feet to match trim color specified.12”

4”

1/4” Max 12”

Preferred Option:

48” H

Attachment 5

Other options may be presented for approval.

The portions of the feet shown overlapping the blue panels should be hidden as much as possible once assembled. Or if installed against a wall and the foot is removed from one side, that side shall have a finished look (without the foot installed).

Panel Unit End View: Option B (triangle feet)

Preferred option is also shown at the bottom of Slide #1 above.

Front View Including a Return (with individual panel sections)

28” L 36” L 36” L 48” H

100” L

Attachment 5

2.5” Thick Panels (1/2 inch variance)

R e t u r n

P a n e l

Preferred Foot Option (Triangle

Foot): Front View

100” L

Attachment 5

28” L 36” L 36” L

36” L

Preferred Foot Option: Aerial View 12” H

Additional feet may be required other than those shown and/or in a different configuration. Feet mounting width varies with the length of the panel sections.

Attachment 5

Feet may be required on both sides of the panel to be adequately supported on its own. Or only on one side if installed against a wall (one side would be removed at installation and left at the facility for future use). Or in a different configuration.

5100” L

Attachment 5

Additional feet may be required other than those shown and/or in a different configuration.

Panel shown was for example purposes only.

The SOW requirements for measurements, colors, etc. are to be followed for panel production.