Attachment 1 CYQL 152003 B3 Combined Drawings11.19.21.pdf
PDF 37 MB Posted
- Attached to
- Repair BE Admin and Shops B4210-4211
- Solicitation number
- W50S6Y24B0003
About this file
This document provides details for a federal contract solicitation for repair services. The Florida National Guard is seeking a single firm fixed-price contract for repair work at BE Admin Shop B4210-4211, including all labor, materials, equipment, and supervision. The contract duration is 300 calendar days from notice to proceed and includes an inspection and punch list period. The NAICS code is 236220 for commercial and institutional building construction, and the small business size standard is $45,000,000. The estimated value of the construction is between $5,000,000 to $10,000,000. A pre-bid conference will be held on January 26, 2024 at 0930 with site visit to follow, and interested contractors should register and follow base access requirements in the solicitation. The solicitation and attachments will be available only through SAM.gov. The opportunity is set aside 100% for small businesses.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT No.:
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
XHEA172010
CONTRACT No.: W9133L-16-D-2007
1005 River Street Port Huron, MI 48060 phone: 810-956-9300 fax: 810-956-9281
REPAIR BASE ENGINEERING ADMIN &
SHOPS, BLDG 4210 & 4211
5269 SR 16 W. STARKE, FL 32091
FLORIDA AIR NATIONAL GUARD
F L O
R
ID
A A
IR
N
A T
IO
N
A L G
U A
R D
S R
W
S
T A
R K
E F
L
R E
P A
IR
B
A S
E E
N G
IN
E
E R
IN
G
A D
M
IN
S
H O
P S
B
L D
G
G-001
COVER SHEET
4363500-171034.01
ATM
PC
November 19, 2021
ATM
11/19/21 B-3 SUBMITTAL
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.:
1005 River Street Port Huron, MI 48060 phone: 810-956-9300 fax: 810-956-9281
ANG NO.: CYQL152003
/1 /2
:4
:2
P M
C R e v it L o c a l\
.0
-A
-R a n d y .m a la n o w s k i.
rv t
F L
O R
ID
A
A
IR
N A
T
IO
N A
L G
U A
R D
S R
W
S
T A
R K
E
F L
G-002
4363500-171034.01
ATM
PC
INDEX
R E
P A
IR
B
A S
E E
N G
IN
E
E R
IN
G
A D
M
IN
S
H O
P S
B
L D
G
November 19, 2021
ATM
CIVIL ENGINEER
STRUCTURAL ENGINEER
ARCHITECT FIRE PROTECTION ENGINEER
PLUMBING ENGINEER ELECTRICAL ENGINEER
MECHANICAL ENGINEER
TECHNOLOGY ENGINEER
SHEET INDEX - VOLUME 1
GENERAL
G-002 INDEX
CIVIL
CD-100 CIVIL DEMOLITION PLAN
CS-100 UTILITY SITE PLAN
STRUCTURAL
S-001 STRUCTURAL NOTES
S-002 STRUCTURAL NOTES
S-005 STATEMENT OF SPECIAL INSPECTIONS AND NOTES
S-006 STRUCTURAL STEEL SPECIAL INSPECTIONS AND NOTES
S-007 STATEMENT OF SPECIAL INSPECTIONS AND NOTES
S-101A FOUNDATION PLAN - BLDG 4210
S-111A FLATWORK PLAN - BLDG 4210
S-111B FLATWORK PLAN - BLDG 4211
S-131A STRUCTURAL FLOOR PLAN - BLDG 4210
S-131B STRUCTURAL FLOOR PLAN - BLDG 4211
S-151A LOW ROOF FRAMING PLAN - BLDG 4210
S-151B LOW ROOF FRAMING PLAN - BLDG 4211
S-152A HIGH ROOF FRAMING PLAN - BLDG 4210
S-501 FOUNDATION DETAILS
S-511 FLATWORK DETAILS
S-531 WALL DETAILS
S-532 WALL DETAILS
S-551 FRAMING DETAILS
S-601 SCHEDULES
ARCHITECTURAL
A-001 NOTES & SYMBOLS
A-002 BUILDING SYSTEMS, INTERIOR PARTITIONS AND NOTES
A-003 INTERIOR PARTITION NOTES AND DETAILS
A-004 ARCHITECTURAL KEYED NOTES
AD100 OVERALL DEMOLITION PLAN
AD101A DEMOLITION FLOOR PLAN - BLDG 4210
AD101B DEMOLITION FLOOR PLAN - BLDG 4211
AD102 OVERALL ROOF DEMOLITION PLAN
AD102A ROOF DEMOLITION PLAN - BLDG 4210
AD102B ROOF DEMOLITION PLAN - BLDG 4211
AD121 OVERALL DEMOLITION CEILING PLAN
AD121A CEILING DEMOLITION PLAN - BLDG 4210
AD121B CEILING DEMOLITION PLAN - BLDG 4211
AD201 BUILDING DEMO ELEVATIONS
AD202 BUILDING DEMO ELEVATIONS
AD311 DEMO WALL SECTIONS
A-100 OVERALL PLAN BUILDING B4210-4211
A-101A FLOOR PLAN - BLDG 4210
A-101B FLOOR PLAN - BLDG 4211
A-102A ATTIC PLAN - BLDG 4210
A-102B UPPER LEVEL PLAN - BLDG 4211
A-104 OVERALL ROOF PLAN
A-104A ROOF PLAN - BLDG 4210
A-104B ROOF PLAN - BLDG 4211
A-104C ROOF PLAN - ALLEY
A-121 OVERALL CEILING PLAN
A-121A CEILING PLAN - BLDG 4210
A-121B CEILING PLAN - BLDG 4211
A-131B EQUIPMENT PLAN - BLDG 4211
A-201 BUILDING ELEVATIONS
A-202 BUILDING ELEVATIONS
A-203 BUILDING REPAIR ELEVATIONS
A-204 BUILDING REPAIR ELEVATIONS
A-211 INTERIOR ELEVATIONS - BLDG 4210
A-212 INTERIOR ELEVATIONS - BLDG 4211
A-213 INTERIOR ELEVATIONS - BLDG 4211
A-214 INTERIOR ELEVATIONS - BLDG 4211
A-301 BUILDING SECTIONS - BLDG 4210
A-302 BUILDING SECTIONS - BLDG 4211
A-305 INTERIOR SECTIONS
A-311 WALL SECTIONS - BLDG 4210
A-312 WALL SECTIONS - BLDG 4210
A-313 WALL SECTIONS - BLDG 4211
A-314 WALL SECTIONS - BLDG 4211
A-321A AIR BARRIER PLAN - BLDG 4211
A-400 ENLARGED PLANS & INTERIOR ELEVATIONS - BLDG 4210
A-401 ENLARGED PLANS & INTERIOR ELEVATIONS - BLDG 4210
A-402 ENLARGED PLANS & INTERIOR ELEVATIONS - BLDG 4211
A-501 EXTERIOR SECTION DETAILS
A-502 EXTERIOR SECTION DETAILS
A-503 INTERIOR SECTION DETAILS
A-504 PLAN DETAILS
A-505 PLAN DETAILS
A-510 CASEWORK & TOILET ACCESSORY DETAILS
A-600 DOOR AND FRAME SCHEDULE
A-601 DOOR AND FRAME DETAILS
A-700 FINISH SCHEDULE
A-701A FINISH PLAN - BLDG 4210
A-701B FINISH PLAN - BLDG 4211
A-801A SIGNAGE PLAN - BLDG 4210
A-801B SIGNAGE PLAN - BLDG 4211
A-802 SIGNAGE SCHEDULE
A-803 SIGNAGE DETAILS
SHEET INDEX - VOLUME 2
FIRE PROTECTION
F-001 FIRE PROTECTION LEGEND & ABBREVIATIONS
F-002 FIRE PROTECTION GENERAL NOTES
F-003 CODE SUMMARY
F-101 LIFE SAFETY PLAN
F-102 FIRE PROTECTION HAZARD CLASSIFICATION PLAN
F-103 FIRE ALARM PLAN - 4210
F-104 FIRE ALARM PLAN - 4211
F-401 FIRE PROTECTION RISER ENLARGED FLOOR PLAN
F-501 FIRE PROTECTION DETAILS
F-601 FIRE ALARM FUNCTIONAL MATRIX
F-602 FIRE ALARM SYSTEM RISER DIAGRAM
PLUMBING
P-001 ABBREVIATIONS, LEGENDS AND GENERAL NOTES
PD101 B4210 PRESSURE PIPING DEMO PLAN
PD102 B4210 DRAINAGE DEMO PLAN
PD103 B4211 PRESSURE PIPING DEMO PLAN
PD104 B4211 DRAINAGE DEMO PLAN
P-101 B4210 PLUMBING PRESS. PIPING PLAN
P-102 B4211 PLUMBING PRESS. PIPING PLAN
P-131 B4210 PLUMBING WASTE PIPING PLAN
P-132 B4120 PLUMBING ABOVE SLAB WASTE AND VENT PIPING PLAN
P-133 B4211 PLUMBING WASTE PIPING PLAN
P-134 B4211 PLUMBING ABOVE SLAB WASTE AND VENT PIPING PLAN
P-401 ENLARGED PRESSURE PIPING PLANS
P-431 ENLARGED SANITARY SEWER PLANS
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-901 PLUMBING RISER DIAGRAM
P-902 PLUMBING RISER DIAGRAM
P-903 PLUMBING RISER DIAGRAM
P-904 PLUMBING RISER DIAGRAM
P-905 PLUMBING RISER DIAGRAM
MECHANICAL
M-001 ABBREVIATIONS, LEGENDS AND GENERAL NOTES
MD101 B4210 MECHANICAL DEMO PLAN
MD102 B4211 MECHANICAL DEMO PLAN
M-100 MECHANICAL ZONING PLAN
M-101 B4210 MECHANICAL FLOOR PLAN
M-102 B4211 MECHANICAL FLOOR PLAN
M-103 B4210 MECHANICAL ROOF PLAN
M-104 B4211 MECHANICAL FLOOR PLAN
M-401 MECHANICAL ENLARGED PLANS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL ISOMETRIC
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-603 MECHANICAL SCHEDULES
M-701 MECHANICAL CONTROLS LEGEND AND ABBREVIATIONS
M-702 MECHANICAL CONTROLS INSTRUCTIONS
M-703 MECHANICAL CONTROLS ELECTRIC UNIT HEATER
M-704 MECHANICAL CONTROLS UTILITY METER
M-705 MECHANICAL CONTROLS DUCTLESS SPLIT SYSTEM
M-706 MECHANICAL CONTROLS VAV AHU
M-707 MECHANICAL CONTROLS VAV AHU (CONT.)
M-708 MECHANICAL CONTROLS EXHAUST FAN OCCUPIED COOLING
M-709 MECHANICAL CONTROLS EXHAUST FAN CONT. OVERRIDE
M-710 MECHANICAL CONTROLS VAV ELEC REHEAT
M-711 MECHANICAL CONTROLS VAV ELEC REHEAT (CONT.)
M-712 MECHANICAL CONTROLS DEDICATED OUTSIDE AIR UNIT
M-713 MECHANICAL CONTROLS DEDICATED OUTSIDE AIR UNIT (CONT.)
M-714 MECHANICAL CONTROLS MAU
M-715 MECHANICAL CONTROLS MAU (CONT.)
M-716 MECHANICAL CONTROLS EXHAUST FAN VEF
ELECTRICAL
E-001 LEGEND, ABBREVIATIONS AND NOTES
ED101 BUILDING 4210 ELECTRICAL LIGHTING DEMOLITION PLAN
ED102 BUILDING 4211 ELECTRICAL LIGHTING DEMOLITION PLAN
ED103 BUILDING 4210 ELECTRICAL POWER & EQUIPMENT DEMOLITION PLAN
ED104 BUILDING 4211 ELECTRICAL POWER & EQUIPMENT DEMOLITION PLAN
ED601 ELECTRICAL DEMOLITION ONE-LINE
ES101 ELECTRICAL SITE PLAN
E-101 BUILDING 4210 ELECTRICAL LIGHTING PLAN
E-102 BUILDING 4211 ELECTRICAL LIGHTING PLAN
E-103 BUILDING 4210 ELECTRICAL POWER PLAN
E-104 BUILDING 4211 ELECTRICAL POWER PLAN
E-105 BUILDING 4210 ELECTRICAL EQUIPMENT PLAN
E-106 BUILDING 4211 ELECTRICAL EQUIPMENT PLAN
E-107 BUILDING 4210 & 4211 ELECTRICAL GROUNDING PLAN
E-108 BUILDING 4210 & 4211 ELECTRICAL LIGHTNING PLAN
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL DETAILS
E-503 ELECTRICAL DETAILS
E-504 ELECTRICAL DETAILS
E-505 ELECTRICAL DETAILS
E-601 ELECTRICAL ONE-LINE
E-602 ELECTRICAL PANEL SCHEDULES
E-603 ELECTRICAL PANEL SCHEDULES
E-604 ELECTRICAL PANEL SCHEDULES
E-605 ELECTRICAL PANEL SCHEDULES
E-606 ELECTRICAL PANEL SCHEDULES
TELECOMMUNICATIONS
T-001 LEGEND, ABBREVIATIONS AND NOTES
TD101 BUILDING 4210 ELECTRICAL TELECOMMUNICATIONS DEMOLITION PLAN
TD102 BUILDING 4211 ELECTRICAL TELECOMMUNICATIONS DEMOLITION PLAN
T-101 BUILDING 4210 ELECTRICAL TELECOMMUNICATIONS PLAN
T-102 BUILDING 4211 ELECTRICAL TELECOMMUNICATIONS PLAN
T-501 TELECOMMUNICATIONS DETAILS
T-502 TELECOMMUNICATIONS DETAILS
BLDG 4210
BLDG 4211
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
DRIVEWAY
EXISTING
DRIVEWAY
EXISTING
GRASSED
AREA
EXISTING
GRASSED
AREA
EXISTING SIDEWALK
EXISTING SIDEWALK
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING SEWER
MANHOLD WITH TRAFFIC
RATED COVER
EXISTING 2" WATER LINE
EXISTING 4" SS
LINE
EXISTING 2.5" W LINE
EXISTING 4"
WATER LINE
EXISTING 6"X4"
TEE WITH 6"
PLUG AND CAP
EXISTING 6"
BACKFLOW
PREVENTER
EXISTING 6"
WATERLINE
EXISTING
4" SS LINE
26 FT
114.6 FT
53 FT
7 FT
MAX
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
SHEET CONTENTS
DO NOT SCALE DRAW INGS
M&H NO.:
DATE:
DESIGNED BY:
DRAW N BY:
CHECKED BY:
ISSUED
SHEET NO.:
1005 River Street Port Huron, MI 48060 phone: 810-956-9300 fax: 810-956-9281
ANG NO.: CYQL152003
11/19/21 B-3 SUBMITTAL
/1 /2
:3
:3
P M
C U s e rs \T
A N
N E
R .A
L L E
N \D o c u m e n ts \1
.0 -M
P -R ta n n e r.
a lle n F
S H
U
.r v t
F L
O R
ID
A
A
IR
N A
T
IO
N A
L G
U A
R D
S R
W
S T
A R
K E
F
L
CD-100
4363500-171034.01
VBD
RC
CIVIL DEMOLITION
PLAN
R E
P A
IR
B
A S
E E
N G
IN
E
E R
IN
G
A D
M
IN
S
H O
P S
B
L D
G
November 19, 2021
JW
NOT FOR CONSTRUCTION
PLAN
NORTH
TRUE
NORTH
1/16" = 1'-0"1
CIVIL DEMOLITION PLAN
EXISTING FIRE HYDRANT TO REMAIN
EXISTING 6" WATER MAIN
SEE PAVEMENT
REPAIR DETAIL ON
1/CD-100
EXISTING FENCE LINE
SCALE: N.T.S.
2 PAVEMENT REPAIR DETAIL
SAW CUT AND PATCH AREA FOR GENERATOR
INSTALLATION (BID OPTION 2). REFER TO E-107
FOR EXTENT AND DETAIL 1/CD-100 FOR REPAIR.
UTILITY TRENCH FOR LIGHTNING PROTECTION
SYSTEM. REFER TO E-107 FOR EXTENT AND DETAIL
1/CD-100 FOR REPAIR. TYPICAL.
SAW CUT SIDEW ALK FOR
INSTALLATION OF LIGHTNING
PROTECTION SYSTEM. SW W 1/CD-100
FOR REPAIR.
UTILITY TRENCH FOR
LIGHTNING PROTECTION
UTILITY TRENCH FOR
LIGHTNING PROTECTION
FIN GRADE
3,000 PSI CONCRETE
2'-0"
6"
COLOR OF FINISH COAT
SHALL BE OSHA SAFETY
FILLED WITH CONCRETE
6" SCHED 40 STEEL PIPE
9" (TYP)
YELLOW
BLDG 4210
BLDG 4211
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
DRIVEWAY
EXISTING
DRIVEWAY
EXISTING
GRASSED
AREA
EXISTING
GRASSED
AREA
EXISTING SIDEWALK
EXISTING SIDEWALK
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING
PARKING
EXISTING SEWER
MANHOLD WITH TRAFFIC
RATED COVER
EXISTING 2" WATER LINE
EXISTING 4" SS
LINE
EXISTING 2.5" W LINE
EXISTING 4"
WATER LINE
EXISTING 6"X4"
TEE WITH 6"
PLUG AND CAP
EXISTING 6"
BACKFLOW
PREVENTER
EXISTING 6"
WATERLINE
EXISTING 4" SS
LINE
26 FT
F T
114.6 FT
F F F
53 FT
F
7 FT
MAX
GENERATOR
4210-HP-1
4210-CU-1
4210-CU-2
4210-CU-3
DCS-1
4211-CU-3
4211-HP-1
4211-CU-1
4211-CU-2
4' - 4"
2'X3'X3' 3000 PSI CONCRETE
THRUST BLOCK
6"X8" TEE
3'
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
SHEET CONTENTS
DO NOT SCALE DRAW INGS
M&H NO.:
DATE:
DESIGNED BY:
DRAW N BY:
CHECKED BY:
ISSUED
SHEET NO.:
1005 River Street Port Huron, MI 48060 phone: 810-956-9300 fax: 810-956-9281
ANG NO.: CYQL152003
11/19/21 B-3 SUBMITTAL
/1 /2
:3
:3
P M
C U s e rs \T
A N
N E
R .A
L L E
N \D o c u m e n ts \1
.0 -M
P -R ta n n e r.
a lle n F
S H
U
.r v t
F L
O R
ID
A
A
IR
N A
T
IO
N A
L G
U A
R D
S R
W
S T
A R
K E
F
L
CS-100
4363500-171034.01
VBD
RC
UTILITY SITE PLAN
R E
P A
IR
B
A S
E E
N G
IN
E
E R
IN
G
A D
M
IN
S
H O
P S
B
L D
G
November 19, 2021
JW
NOT FOR CONSTRUCTION
NEW 6" WET TAP
FOR FIRE WATER
SERVICE.
EXISTING FIRE HYDRANT TO REMAIN
EXISTING 6" WATER MAIN
PLAN
NORTH
TRUE
NORTH
1/16" = 1'-0"1
UTILITIES SITE PLAN
CONNECT TO FIRE RISER
PER FP DRAW INGS
8" X 6"
REDUCER
EXISTING FENCE LINE
NEW 6" DOUBLE DETECTOR BFP
ASSEMBLY IN INSULATED
ENCLOSURE.
8" PVC
REMOTE
FDC
NEW BOLLARD
(TYP 6)
SCALE: N.T.S.
2 BOLLARD DETAIL
NEW BOLLARD
(TYP 6)
SCALE: N.T.S.
3 FIRE DEPARTMENT CONNECTION DETAIL
SCALE: N.T.S.
4 RESTRAINED PIPE TABLE
FOUNDATION NOTES
F-1. FOOTING SUBGRADES SHALL BE CLEAN AND FREE OF DEBRIS, STANDING
WATER, AND LOOSE SOIL.
F-2. ALL COLUMN FOOTINGS ARE TO BE CENTERED UNDER COLUMN
CENTERLINES, UNLESS INDICATED OTHERWISE.
F-3. THE FOUNDATION CONTRACTOR SHALL FULLY REVIEW UNDER-GROUND
PLUMBING DRAWINGS AND SHALL COORDINATE WITH THE UNDER-GROUND
PLUMBING CONTRACTOR TO DEPRESS FOOTINGS AND PROVIDE PIPE
SLEEVES THROUGH FOUNDATION WALLS AS NECESSARY TO ACCOMMODATE
PLUMBING LINES OR TRAPS WHICH PENETRATE CONCRETE FOOTINGS OR
FOUNDATIONS.
F-4. PROVIDE PVC SLEEVES THROUGH FOUNDATION WALLS FOR PIPE,
CONDUIT, AND CABLE PENETRATIONS, INCLUDING ELECTRICAL GROUNDING
SYSTEM CABLES. SEE APPROPRIATE DRAWINGS FOR LOCATIONS/SIZES.
PLACE SLEEVES IN LOCATIONS TO AVOID DISPLACING REINFORCING STEEL.
F-5. COORDINATE WITH ARCHITECTURAL AND CIVIL DRAWINGS FOR
MISCELLANEOUS FOUNDATIONS NOT SHOWN ON STRUCTURAL DRAWINGS.
F-6. CONTROL JOINTS IN THE CAST-IN-PLACE CONCRETE FOUNDATION WALLS
SHALL BE PLACED AT SPACING NOT TO EXCEED 20' O.C. OR AS LOCATED PER
DRAWINGS AND SHOULD ALIGN WITH MASONRY CONTROL JOINTS WHERE
APPLICABLE. SEE DETAIL SHEETS FOR CONTROL JOINT DETAILS. PROVIDE
VERTICAL "V" GROOVE AT ALL CONSTRUCTION AND CONTROL JOINTS.
CONTRACTOR SHALL SUBMIT PLANS OF JOINT LOCATIONS FOR APPROVAL.
F-7. A LEAN CONCRETE MUD SLAB 2" TO 3" THICK SHALL BE USED IN THE FOOTING
EXCAVATION IF THE BOTTOM OF THE EXCAVATION TENDS TO BECOME
MUDDY AND SOFT DUE TO CONSTRUCTION ACTIVITY. LEAN CONCRETE
SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2000 PSI.
F-8. COORDINATE GROUNDING REQUIREMENTS FOR FOUNDATION/FOOTING
REINFORCING STEEL WITH ELECTRICAL DRAWINGS. COORDINATE
INSTALLATION OF GROUNDING WIRES/EQUIPMENT WITH ELECTRICAL
CONTRACTOR PRIOR TO CASTING CONCRETE. REFER TO NOTE CR-11 FOR
ADDITIONAL INFORMATION.
F-9. SEE TYPICAL SLAB-ON-GRADE DETAILS FOR SLAB AND SUB-BASE
REQUIREMENTS. THESE WILL BE TYPICAL THROUGHOUT UNLESS NOTED
OTHERWISE.
CONCRETE & REINFORCING STEEL NOTES
MATERIAL PROPERTIES (U.N.O.)
COMPRESSIVE STRENGTH - F'c = 4 KSI CONCRETE REINFORCEMENT - Fy = 60 KSI (A615 GR 60)
CR-1. PROVIDE HOT/COLD WEATHER PROCEDURES AND PROTECTION IN
ACCORDANCE WITH ACI RECOMMENDATIONS AND PROJECT
SPECIFICATIONS.
CR-2. ALL CONCRETE DESIGN AND CONSTRUCTION SHALL CONFORM WITH THE
LOCAL BUILDING CODE REQUIREMENTS AND THOSE OF THE FOLLOWING
STANDARDS (LATEST EDITION):
"ACI 318, BUILDING CODE REQUIREMENTS FOR REINFORCED CONC."
"ACI 315, DETAILS AND DETAILING OF CONCRETE REINFORCEMENT"
"ACI 301, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BLDGS."
"ACI 307, RECOMMENDED PRACTICE FOR CONCRETE FORM WORK"
CR-3. REINFORCING SHALL BE DETAILED IN ACCORDANCE WITH ACI 315.
CR-4. ALL REINFORCEMENT BARS SHALL BE FABRICATED IN ACCORDANCE WITH
THE LATEST CRSI MANUAL OF STANDARD PRACTICE AND SHALL BE CLEAN
AND FREE OF GREASE AND SCALING RUST.
CR-5. SEE SECTION 033000 OF SPECIFICATIONS FOR INFORMATION REGARDING
CONCRETE MIX DESIGN, TESTING, MATERIALS, AND ADMIXTURES.
CR-6. CONCRETE REINFORCEMENT PROTECTION/CLEAR COVER, U.N.O.:
FOOTINGS:
BOTTOM & SIDES 3"
TOP 2"
WALLS:
EXTERIOR EXPOSURE 2"
INTERIOR EXPOSURE 1"
BEAMS/COLUMNS:
OVER TIES OR STIRRUPS 1 1/2"
CR-7. ALL BAR LAPS SHALL CONFORM TO ACI 318-14, PARAGRAPH 25.5.1, CLASS
"B" SPLICE CRITERIA. USE TOP BAR LAP LENGTHS FOR TOP BARS IN SLABS
AND BEAMS OVER 12" DEEP.
CR-8. LAP LENGTH SHALL BE SPECIFICALLY NOTED ON SHOP DRAWINGS WHERE
MORE THAN ONE BAR MAKES UP A CONTINUOUS STRING.
CR-9. HORIZONTAL BARS SHALL BE DETAILED TO SHOW THE DISTANCE FROM AT
LEAST ONE END OF THE BAR TO THE NEAREST BUILDING GRID LINE OR
WALL.
CR-10. CONTINUOUS TOP AND BOTTOM BARS, WHEN SHOWN IN TRANSVERSE
SECTION ONLY, SHALL BE LAPPED AS FOLLOWS:
TOP BARS NEAR MID-SPANS; BOTTOM BARS DIRECTLY OVER SUPPORTS,
U.N.O.
CR-11. PROVIDE ONE (1) HOOKED REINFORCING BAR IN CONCRETE FOOTING
TO SERVE AS A “CONCRETE ENCASED ELECTRODE” IN ACCORDANCE WITH
THE NATIONAL ELECTRIC CODE. COORDINATE WITH ELECTRICAL
CONTRACTOR FOR EXACT LOCATION. HOOKED REINFORCING BAR SHALL
CONFORM TO THE FOLLOWING:
A. UNCOATED, LOW-ALLOY STEEL, CONFORMING TO ASTM A706.
B. BAR SIZE NUMBER 4 HOOKED AT ONE END ONLY.
C. MINIMUM HORIZONTAL LENGTH OF REINFORCING BAR ENCASED IN
CONCRETE FOOTING SHALL BE 20’-0” AS DEFINED IN NEC, ARTICLE 250.
D. MINIMUM VERTICAL PROJECTION OF REINFORCING BAR ABOVE
CONCRETE SLAB SHALL BE 0’-6”.
E. MINIMUM COVER ALL AROUND REINFORCING BAR SHALL BE 2”.
CR-12. HOOK HORIZONTAL WALL AND BEAM REINFORCING BARS AT
DISCONTINUOUS ENDS, TYPICAL UNLESS INDICATED OTHERWISE. EXTEND
REINFORCEMENT TO FAR FACE OF PIERS/PEDESTALS AND/OR COLUMNS
UNLESS INDICATED OTHERWISE.
CR-13. WATER STOPS SHALL BE PROVIDED IN HORIZONTAL AND VERTICAL
CONSTRUCTION JOINTS WHERE FINISHED FLOOR IS BELOW EXTERIOR
GRADE UNLESS OMISSION IS APPROVED BY THE ENGINEER.
CR-14. PROVIDE ADDITIONAL #4 BARS AT 4'-0" LONG 1" BELOW TOP OF SLAB AT
45° TO ALL RE-ENTRANT CORNERS,OPENINGS IN CONCRETE SLABS AND
AS INDICATED ON DRAWINGS.
CR-15. REFER TO FLATWORK DRAWINGS AND/OR SPECIFICATIONS FOR
SLAB-ON-GRADE FINISH TYPES AND DEPRESSIONS REQUIRED FOR MATS,
TILE, AND OTHER FINISH MATERIALS.
CR-16. THICKEN THE SLAB-ON-GRADE BENEATH INTERIOR MASONRY PARTITIONS
8 INCHES BELOW BOTTOM OF SLAB ON GRADE. THICKENED PORTION TO
EXTEND 8 INCHES BEYOND THE FACE OF THE WALL ON EACH SIDE.
REINFORCE THE THICKENED PORTION WITH (3) #3CONTINUOUS,
LONGITUDINAL REINFORCING BARS AND #5 TRANSVERSE BARS AT 16" O.C.,
UNLESS INDICATED OTHERWISE.
CR-17. PITCH CONCRETE TO FLOOR DRAINS. COORDINATE WITH PLUMBING AND
ARCHITECTURAL DRAWINGS.
CR-18. PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS-ON-GRADE
AT 15 FOOT MAXIMUM CENTERS EACH DIRECTION, UNLESS INDICATED
OTHERWISE. CONTRACTOR SHALL SUBMIT PLANS OF JOINT LOCATIONS TO
THE ARCHITECT/ENGINEER FOR APPROVAL PRIOR TO CASTING SLABS-ON
GRADE. COORDINATE WITH ARCHITECTURAL DRAWINGS AND FLOOR
FINISHES SUCH AS TILE AND TERRAZZO.
CR-19. ALL DOWELS INTO EXISTING CONCRETE OR SOLID MASONRY TO BE EPOXY
ADHESIVE ANCHORS.
CR-20. ALUMINUM CONDUIT IS NOT PERMITTED TO BE EMBEDDED IN CONCRETE.
GENERAL NOTES
G-1. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO START
OF CONSTRUCTION - RESOLVE ANY DISCREPANCY WITH ARCHITECT/ENGINEER.
G-2. FOR CLARITY, ALL EXTERIOR SLABS AND SIDEWALKS MAY NOT BE SHOWN.
FOR EXACT DIMENSIONS, LOCATIONS, JOINTS AND SCORE LINES, SEE
ARCHITECTURAL AND/OR CIVIL DRAWINGS.
G-3. VERIFY ALL SIZES, WEIGHTS AND LOCATIONS OF MECHANICAL AND
ELECTRICAL EQUIPMENT, ROOF PENETRATIONS, DUCTS, ETC. WITH
MECHANICAL AND ELECTRICAL CONTRACTORS AND FIELD CONDITIONS.
G-4. DETAILS MARKED "TYPICAL" MAY OR MAY NOT BE CUT ON PLANS, BUT
SHALL APPLY UNLESS NOTED OTHERWISE.
G-5. STRUCTURAL SYSTEM IS DESIGNED TO WORK AS A COMPLETED SYSTEM,
ANY SHORING OR BRACING NECESSARY DURING CONSTRUCTION SHALL
BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
G-6. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING PLANS
FOR SLEEVES, INSERTS, ETC. NOT SHOWN ON STRUCTURAL PLANS.
G-7. NO PIPES OR SLEEVES FOR MECHANICAL TRADES SHALL PASS THROUGH
STRUCTURAL MEMBERS WITHOUT APPROVAL OF THE STRUCTURAL
ENGINEER.
G-8. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL SITE SAFETY AND ALL
ACCIDENTS WHICH RESULT IN DEATH, PERSONAL INJURY, OR DAMAGE TO
PROPERTY ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE
OF THE WORK.
G-9. CONTRACTOR SHALL POST LIVE LOADS PER SECTION 106.1 OF THE
GOVERNING CODE.
G-10. SECTIONS, DETAILS, AND NOTES SHOWN ON THE DRAWINGS ARE INTENDED
TO BE TYPICAL AND SHALL APPLY TO SIMILAR CONDITIONS ELSEWHERE,
UNLESS OTHERWISE SHOWN.
DO NOT SCALE DRAWINGS!!!!
EARTHWORK NOTES
EW-1. REFERENCE SECTION 312000 - EARTH MOVING FOR DEFINITION OF
MATERIALS AND COMPACTION REQUIREMENTS.
EW-2. REFERENCE SECTION 312000 - EARTH MOVING FOR REQUIREMENTS FOR
EXCAVATION AND CONTROL OF SURFACE WATER AND GROUND WATER.
EW-3. UNLESS NOTED OTHERWISE, THE CONTRACTOR SHALL RETAIN AN
INDEPENDENT, QUALIFIED GEOTECHNICAL ENGINEERING FIRM/TESTING
AGENCY TO IDENTIFY AREAS OF POOR SOILS, TO MONITOR PROPER
SUBGRADE PREPARATIONS AND TO OVERSEE AND TEST THE PLACEMENT
OF COMPACTED FILL MATERIAL.
EW-4. ALL SUBTERRANEAN STRUCTURES, UTILITIES, PIPING, ETC. IN THE AREA
OF EXCAVATIONS SHALL BE LOCATED AND MARKED BY CONTRACTOR
PRIOR TO EARTH REMOVAL WORK. CONTRACTOR SHALL MAINTAIN
MARKERS UNTIL EXCAVATION ACTIVITIES HAVE CEASED.
IF UNDERGROUND UTILITY CONFLICTS ARE DISCOVERED BEFORE OR
ENCOUNTERED DURING EXCAVATION, NOTIFY THE ARCHITECT/ENGINEER
IMMEDIATELY.
EW-5. BEFORE PLACING FOOTINGS, FOUNDATIONS OR SLAB-ON-GRADE, THE
SUB-GRADE SHALL BE PREPARED AND INSPECTED AS REQUIRED BY THE
SPECIFICATIONS.
EW-6. DO NOT BACKFILL OR FILL SOIL MATERIAL ON SURFACES THAT ARE
MUDDY, FROZEN, OR CONTAIN FROST AND/OR ICE.
EW-7. PLACE BACKFILL AND FILL SOIL MATERIALS EVENLY ON ALL SIDES OF
STRUCTURES TO REQUIRED ELEVATIONS AND UNIFORMLY ALONG
THE FULL LENGTH OF EACH STRUCTURE.
ABBREVIATIONS
B.O.
GENERAL SYMBOLS
KEYED NOTE
STRUCTURAL WALL TYPE
ELEVATION
DECK SPAN
STRUCTURAL SLAB TYPE
STRUCTURAL ELEVATION
DETAIL OR SECTION
LINTEL DESIGNATION
SLAB X
S-201 #
S-501
SW#
STRUCTURAL SYMBOLOGY
MASONRY (CMU) WALL
ON CONCRETE FOOTING
CONCRETE FOOTING
CONCRETE FOUNDATION WALL
ON CONCRETE FOOTING
TOP OF FOOTING ELEVATION
TOP OF WALL ELEVATION
FOOTING STEP
STRIP FOOTING DESIGNATION
DENOTES DEPRESSION FOR
WALL/DOOR OPENING (-8" U.N.O.)
INDICATES PIER MARK
INDICATES PIER
INDICATES COLUMN
INDICATES CONCRETE FOOTING
INDICATES SPREAD FOOTING MARK
INDICATES NEW GRID DESIGNATION
(HEXAGON SHAPE AT EXISTING GRID)
TOF
96'-0"
TOW
100'-0"
SF1
A
F1 P1
FOUNDATION PLAN
FRAMING PLAN
INDICATES BEAM FRAMING OVER HOLLOW
STRUCTURAL SECTION (HSS) COLUMN
INDICATES BEAM FRAMING
OVER WIDE FLANGE (WF) COLUMN
INDICATES BRACING CONNECTED TO BEAM
(BELOW FRAMING MEMBER)
INDICATES BEAM FRAMING
INTO SIDE OF COLUMN
INDICATES MOMENT CONNECTION
W x
(0
[1 k
(0 .7
INDICATES REQUIRED UPWARD CAMBER
IN BEAM (INCHES)
INDICATES BEAM SIZE
INDICATES TOP OF STEEL ELEVATION
INDICATES NUMBER OF 3/4" x 5" SHEAR STUDS
FULLY WELDED TO TOP OF BEAM PER 1/2-SPAN
INDICATES CONNECTION DESIGNED BY FABRICATOR
TO DELIVER 46k VERTICAL LOAD TO CENTERLINE
OF COLUMN OR CONNECTION MEMBER
INDICATES TYPICAL BEAM SHEAR SPLICE
INDICATES BEAM FRAMING INTO SIDE OF BEAM
INDICATES BEAM FRAMING OVER BEAM
MASONRY NOTES
MATERIAL PROPERTIES (U.N.O.)
COMPRESSIVE STRENGTH - F'm = 2000 PSI
- F'cu = 2000 PSI MASONRY REINFORCEMENT - Fy = 60 KSI (A615 GR 60)
MORTAR - TYPE S (ASTM C270)
GROUT @ 28-DAYS - 2500 PSI (ASTM C476)
M-1. PROVIDE HOT AND COLD WEATHER PROCEDURES AND TEMPORARY
MOISTURE PROTECTION IN ACCORDANCE WITH ACI RECOMMENDATIONS AND
PROJECT SPECIFICATIONS.
M-2. MASONRY SHALL BE PLACED IN ONE-HALF RUNNING BOND U.N.O.
M-3. HOLLOW MASONRY UNITS SHALL BE LAID WITH FULL HEAD JOINTS AND FULL
BED JOINTS OF THE FACE SHELLS AND UNDER WEBS WHERE THE ADJACENT
CELLS ARE TO BE FILLED WITH GROUT AND AT THE BOTTOM COURSE.
M-4. WHERE MASONRY IS APPLIED ADJACENT TO STEEL MEMBERS (BEAMS AND
COLUMNS) PROVIDE ANCHORING DEVICES PER SPECIFICATIONS.
M-5. REFER TO ARCHITECTURAL PLANS AND DOOR/FRAME SCHEDULES FOR
LINTEL ROUGH OPENING LOCATIONS, SIZES, AND ELEVATIONS.
M-6. ALL MASONRY WALLS ARE TO HAVE 9 GAUGE HORIZONTAL JOINT
REINFORCEMENT WHICH DOES NOT EXCEED 16 INCHES ON CENTER
VERTICALLY.
M-7. ALL LAPS SHALL BE 48 BAR DIAMETERS UNLESS INDICATED OTHERWISE.
M-8. GROUT SOLID ALL JAMBS IN ALL MASONRY WALLS FULL HEIGHT TO
UNDERSIDE OF LINTEL. EXTEND GROUTED JAMB FROM FACE OF MASONRY
OPENING AT LEAST 24" (A MINIMUM OF 3 CELLS). AT OTHER BEAM BEARING
LOCATIONS, GROUT SOLID A MINIMUM 24"x24" AREA BENEATH THE BEARING
PLATE, UNLESS INDICATED OTHERWISE.
M-9. PROVIDE CORNER SPLICE BARS FOR ALL BOND BEAMS OCCURRING AT
CORNERS OR WALL INTERSECTIONS. SPLICE BAR TO BE THE SAME SIZE AS
BARS IN THE BOND BEAM.
M10. ALL NON-STRUCTURAL MASONRY WALLS SHALL BE REINFORCED WITH A
MINIMUM #5 VERTICAL BARS AT 48" O.C. WITH THAT CORE GROUTED AND
HORIZONTAL JOINT REINFORCEMENT AT 16" O.C. THE BOTTOM TWO
COURSES SHALL BE GROUTED SOLID. PROVIDE A CONTINUOUS BOND BEAM
AT TOP OF WALL WITH (2) #5 BARS CONTINUOUS, GROUT BOND BEAM SOLID.
PROVIDE #5 DOWEL AT 48" O.C., INTO FOOTINGS.
M-11. USE SLEEVE ANCHORS IN NON-STRUCTURAL MASONRY WALL PARTITIONS,
UNLESS INDICATED OTHERWISE.
M-12. REFER TO STRUCTURAL AND/OR ARCHITECTURAL DRAWINGS FOR CONTROL
JOINT LOCATIONS. WHERE MASONRY CONTROL JOINT LOCATIONS ARE NOT
INDICATED, PROVIDE THEM AT 25' MAXIMUM CENTERS; SUBMIT MASONRY
CONTROL JOINT LAYOUT TO THE ENGINEER FOR APPROVAL.
M-13. PROVIDE HORIZONTAL BOND BEAMS (DIAPHRAGM CHORDS) WITH (2) #5 BARS
CONTINUOUS, BENEATH FLOOR/ROOF MEMBER BEARING ELEVATIONS AND AT
DECK EDGE.
M-14. PROVIDE 10 GAGE BENT SLIP JOINT PLATES 4" x 4" x 1'-0" LONG AT 3'-0" O.C.
EACH SIDE OF THE TOP OF ALL NON- STRUCTURAL MASONRY WALLS.
ATTACH TO UNDERSIDE OF METAL ROOF DECK OR STRUCTURAL STEEL WITH
3 (MIN.) SELF-DRILLING, SELF-THREADING SCREWS (#12) AS REQUIRED BY
THICKNESS OF BASE METAL. ATTACH TO UNDERSIDE OF CONCRETE DECK
WITH 3 (MIN.) SELF-TAPPING CONCRETE SCREWS 3/16" DIA. SEE
ARCHITECTURAL DRAWINGS FOR NON-STRUCTURAL MASONRY WALL
LOCATIONS. MAINTAIN 1" (MIN.) GAP BETWEEN TOP OF MASONRY WALL AND
BOTTOM OF STRUCTURE. DO NOT ATTACH PLATES TO MASONRY WALL,
UNLESS INDICATED OTHERWISE.
L#
FOUNDATION WALL DESIGNATIONFW08
INDICATES KNEE BRACING CONNECTED TO BEAM
(BELOW FRAMING MEMBER)
INDICATES COLLECTOR CONNECTION
STRUCTURAL DESIGN CRITERIA
1. GOVERNING CODE: UFC 1-200-01 WITH CHANGE 1, DATED 10-01-2020 (IBC 2018)
2. RISK CATEGORY: II
3. FLOOR LIVE LOAD (1603.1.1) 100 PSF
4. ROOF LIVE LOAD (1603.1.2)
MINIMUM ROOF LIVE LOAD: 20 PSF
5. ROOF SNOW LOAD (1603.1.3)
GROUND SNOW LOAD: PG = 0 PSF
FLAT-ROOF SNOW LOAD: PF = NA
SNOW EXPOSURE FACTOR: CE = NA
SNOW LOAD IMPORTANCE FACTOR: IS = NA
THERMAL FACTOR: CT = NA
6. WIND DESIGN DATA (1603.1.4)
ULTIMATE WIND SPEED (3-SECOND GUST): VULT = 123 MPH
NOMINAL WIND SPEED (3-SECOND GUST) VASD = 96 MPH
WIND EXPOSURE: C
INTERNAL PRESSURE COEFFICIENT: GCPI = +/- 0.18
7. EARTHQUAKE DESIGN DATA (1603.1.5)
IMPORTANCE FACTOR: IE = 1.0
MAPPED, MCE, 5% DAMPED, SPECTRAL ACCELERATIONS:
AT SHORT PERIODS: SS = 0.087 G
AT A PERIOD OF 1 SECOND: S1 = 0.049 G
SITE CLASS: D (ASSUMED)
DESIGN EARTHQUAKE SPECTRAL ACCELERATIONS
AT SHORT PERIODS: SDS = 0.093 G
AT A PERIOD OF 1 SECOND: SD1 = 0.078 G
SEISMIC DESIGN CATEGORY: SDC = B
BASIC SEISMIC-FORCE-RESISTING-SYSTEM: SFRS = A.9 ORDINARY REINFORCED
MASONRY SHEAR WALLS.
(TABLE 12.2-1)
DESIGN BASE SHEAR: VS = 34.3 KIPS (B4210)
= 46.4 KIPS (B4211)
SEISMIC RESPONSE COEFFICIENTS: CS = 0.047
RESPONSE MODIFICATION FACTOR: R = 2
ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
8. GEOTECHNICAL DESIGN DATA (1603.1.6)
NET ALLOWABLE SOIL BEARING PRESSURE 2500 PSF PER ORIGINAL DESIGN
DOCUMENTS DATED 09/16/1991
9. FLOOD DESIGN DATA (1603.1.7)
BUILDING IS NOT LOCATED IN FLOOD HAZARD AREA; THEREFORE FLOOD
DESIGN DATA IS NOT REQUIRED
10. SPECIAL LOADS (1603.1.8)
COLD FORMED METAL TRUSS TYPICAL DEAD LOAD (U.N.O.)
TOP CHORD: 10 PSF + 5 PSF COLLATERAL
BOTTOM CHORD: 5 PSF COLLATERAL
SEE SHEET S-152A ROOF FRAMING PLAN GENERAL NOTE #5 FOR ADDITIONAL
BOTTOM CHORD LOADING REQUIREMENTS.
11. PHOTOVOLTAIC PANEL SYSTEM LOADS (1603.1.8.1)
PANEL SYSTEM: N/A
SUPPORT SYSTEM: N/A
12. ROOF RAIN LOAD DATA (1603.1.9)
RAIN INTENSITY: i = 4.5 IN/HR
13. STRUCTURAL OBSERVATIONS FOR SEISMIC AND/OR WIND RESISTANCE
STRUCTURAL OBSERVATIONS FOR WIND AND SEISMIC RESISTANCE ARE NOT
REQUIRED.
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.:
1005 River Street Port Huron, MI 48060 phone: 810-956-9300 fax: 810-956-9281
/1 /2
:0
:1
P M
C R e v it L o c a l\
.0
-S
-R
D e v ik a .D e M a ri o n
.r v t
F L
O R
ID
A
A
IR
N A
T
IO
N A
L G
U A
R D
S R
W
S
T A
R K
E
F L
S-001
4363500-171034.01
DND
JAL
STRUCTURAL NOTES
R E
P A
IR
B
A S
E E
N G
IN
E
E R
IN
G
A D
M
IN
S
H O
P S
B
L D
G
November 19, 2021
DRM
B.O. = BOTTOM OF ________
BP# = BASE PLATE TYPE
BRG = BEARING
C TO C = CENTER TO CENTER
CCJ = CONSTRUCTION CONTROL JOINT
CJ = CONTROL JOINT
CLSM = CONTROLLED LOW STRENGTH MATERIAL ("FLOWABLE FILL")
CONT = CONTINUOUS
DBLT = DOUBLE-TEE
DIA = DIAMETER
DTB = DOUBLE-TEE BEARING
EF = EACH FACE
EL = ELEVATION
EW = EACH WAY
F# = SPREAD FOOTING TYPE
FDTN = FOUNDATION
FV = FIELD VERIFY
GALV = GALVANIZED
HPC = HIGH PERFORMANCE COATING
JB = JOIST BEARING
LLH = LONG LEG HORIZONTAL
LLV = LONG LEG VERTICAL
NIC = NOT IN CONTRACT
NTS = NOT TO SCALE
OC = ON CENTER
P# = PIER TYPE
PCB = PRECAST BEARING (ELEVATION)
PRCST = PRECAST
Rxn = REACTION
SF# = STRIP FOOTING TYPE
SIM = SIMILAR
SST = STAINLESS STEEL
STL = STEEL
T.O. = TOP OF ________
TBD = TO BE DETERMINED
TOC = TOP OF COLUMN
TOF = TOP OF FOOTING
TOL = TOP OF LEDGE
TOP = TOP OF PIER
TOS = TOP OF STEEL
TOW = TOP OF WALL
TPC = TOP OF PRECAST
TSL = TOP OF SLAB
TYP = TYPICAL
UNO = UNLESS NOTED OTHERWISE
WWF = WELDED WIRE FABRIC/REINFORCEMENT
STRUCTURAL STEEL NOTES
MATERIAL PROPERTIES (U.N.O.)
W-SHAPES - Fy = 50 KSI (A992 OR A572 Gr 50) C-SHAPES & ANGLES - Fy = 36 KSI (A36) PLATES & BARS - Fy = 36 KSI (A36) RECTANGULAR HSS - Fy = 46 KSI (A500 Gr B) ROUND HSS - Fy = 42 KSI (A500 Gr B) PIPE - Fy = 35 KSI (A53 Gr B) RODS - Fy = 36 KSI (A36)
S-1. STEEL BEAMS WITH RESIDUAL CAMBER RESULTING FROM MILL FABRICATION
OR ROLLING SHALL BE SHOP FABRICATED AND ERECTED SUCH THAT THIS
RESIDUAL CAMBER COUNTERACTS GRAVITY LOAD DEFLECTION.
S-2. ALL BOLTED CONNECTIONS SHALL UTILIZE 3/4 INCH DIAMETER A325
BOLTS TIGHTENED TO THE SNUG-TIGHT CONDITION. THE SNUG-TIGHT
CONDITION IS DEFINED BY THE RCSC'S "SPECIFICATION FOR STRUCTURAL
JOINTS USING ASTM A325 OR A490 BOLTS", UNLESS INDICATED OTHERWISE.
S-3. STEEL CONNECTIONS NOT DETAILED ON THE PLANS ARE TO BE THE
FABRICATOR'S STANDARD AND ARE TO BE SELECTED AND DESIGNED IN
ACCORDANCE WITH AISC ASD SPECIFICATIONS, TYPE 2 FRAMING
CONNECTIONS, FOR THE REACTIONS INDICATED.
MINIMUM NO. BOLTS PER CONNECTION
n = 2 FOR MEMBERS 10 INCHES DEEP OR LESS n = 3 FOR MEMBERS 12 TO 15 INCHES DEEP n = 4 FOR MEMBERS 16 INCHES DEEP n = 5 FOR MEMBERS 18 INCHES DEEP n = 6 FOR MEMBERS 21 INCHES DEEP n = 7 FOR MEMBERS 24 TO 27 INCHES DEEP n = 8 FOR MEMBERS 30 INCHES DEEP n = 9 FOR MEMBERS 33 INCHES DEEP n = 10 FOR MEMBERS 36 INCHES DEEP
S-4. THE MINIMUM CONNECTION PLATE/ANGLE THICKNESS SHALL BE 5/16", THE
MINIMUM WELD 1/4", AND THE MINIMUM DESIGN LOAD ON ANY CONNECTION
10 KIPS, UNLESS INDICATED OTHERWISE.
S-5. ALL ANCHOR BOLTS ARE TO BE 3/4" INCH DIAMETER F1554 Gr. 36 THREADED
RODS UNLESS INDICATED OTHERWISE. (2)-1/2 INCH DIAMETER ANCHOR BOLTS
SHALL BE PROVIDED AT ALL BEAM AND LINTEL BEARINGS ON CONCRETE
OR MASONRY, UNLESS INDICATED OTHERWISE.
S-6. POST INSTALLED ANCHORS ARE TO BE ADHESIVE ANCHORS. INSTALL
ANCHORS WITH EMBEDMENT DEPTHS INDICATED, UNLESS INDICATED
OTHERWISE.
S-7. STUD ANCHORS ARE TO BE NELSON STUDS OR EQUAL (ASTM A108).
S-8. BEAM AND LINTEL PLATES SHALL BE FULLY GROUTED WITH A MINIMUM
1/2" NON-SHRINK GROUT.
S-9. ALL WELDING OF NEW STEEL IS TO BE WITH E70XX ELECTRODES, U.N.O.
WELDING SHALL BE IN ACCORDANCE WITH THE LATEST AWS SPECIFICATIONS
BY CERTIFIED WELDERS.
S-10. WHEN FIELD WELDING TO EXISTING STEEL, ADJUST WELDING PROCEDURES
AS REQUIRED TO BE COMPATIBLE WITH THE NEW AND EXISTING STEEL.
S-11. THE CONTRACTOR SHALL FURNISH AND INSTALL MISCELLANEOUS STEEL
(CURBS, HANGERS, BRACING, ETC.) AS INDICATED AND AS NECESSARY
PER ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS.
S-12. ALL EXTERIOR STEEL SUCH AS, MASONRY SHELF ANGLES, ANCHOR BOLTS,
LINTEL BEAMS, AND LINTEL PLATES SHALL BE HOT DIPPED GALVANIZED
ACCORDING TO ASTM A123.
METAL DECK
MATERIAL PROPERTIES (U.N.O)
ROOF DECK: GALVANIZED, Fy = 50 KSI
MD-1.SEE PLAN FOR DEPTH AND GAUGE.
MD-2.METAL DECKING SHALL BE CONTINUOUS OVER 3 SPANS AND HAVE JOINTS
OVER SUPPORTING MEMBERS, UNLESS INDICATED OTHERWISE.
MD-3.BUTTON PUNCHING ROOF DECK IS NOT PERMITTED. REFERENCE
DRAWINGS FOR ROOF DECK ATTACHMENT REQUIREMENTS. STRUCTURAL
DIAPHRAGM ACTION IS PROVIDED BY THE ROOF DECK AND ITS ATTACHMENT.
MD-4.ALL MISCELLANEOUS OPENINGS IN METAL ROOF DECK ARE TO BE FRAMED
BY L5x3x3/8 ANGLES. LONG LEG OF ANGLES SHALL BE VERTICAL. ANGLES
SHALL BE WELDED TO THE TOP CHORD/FLANGE OF ROOF FRAMING AND
EACH OTHER, UNLESS INDICATED OTHERWISE.
MD-5.CONTRACTOR IS RESPONSIBLE FOR PROVIDING COLUMN CLOSURES AND ALL
OTHER RELATED ACCESSORIES REQUIRED FOR A COMPLETE DECK
INSTALLATION AT ROOFS AND FLOORS.
SHOP DRAWINGS
SD-1. SHOP DRAWINGS SHALL BE SUBMITTED FOR STRUCTURAL ITEMS AS
REQUIRED BY THE SPECIFICATIONS. CONSTRUCTION DOCUMENTS SHALL
NOT BE REPRODUCED FOR USE AS SHOP DRAWINGS.
SD-2. THE GENERAL CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS AND
PRODUCT DATA FOR CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS
PRIOR TO SUBMITTAL. REVIEWED SUBMITTALS SHALL BE STAMPED BY THE
CONTRACTOR. ANY SHOP DRAWING OR PRODUCT DATA NOT REVIEWED AND
STAMPED BY THE GENERAL CONTRACTOR WILL BE REJECTED. GENERAL
CONTRACTOR SHALL CLOUD OR FLAG ALL ITEMS NOT IN ACCORDANCE WITH
THE CONTRACT DOCUMENTS AND SHALL VERIFY ALL DIMENSIONS.
SD-3. ANY CHANGES, SUBSTITUTIONS OR DEVIATIONS FROM THE ORIGINAL
CONTRACT DRAWINGS SHALL BE CLOUDED BY THE MANUFACTURER OR
FABRICATOR. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS WHICH ARE
CLOUDED OR FLAGGED BY SUBMITTING PARTIES SHALL NOT BE CONSIDERED
APPROVED AFTER THE ENGINEER'S REVIEW, UNLESS SPECIFICALLY NOTED
ACCORDINGLY BY THE ENGINEER.
SD-4. THE APPROVED SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL
CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY ARE NOT
TO BE CONSIDERED CHANGES TO THE ORIGINAL CONTRACT DRAWINGS. IT IS
THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ITEMS OMITTED OR
SHOWN INCORRECTLY ARE CONSTRUCTED IN ACCORDANCE WITH THE
CONTRACT DRAWINGS.
SD-5. SHOP DRAWING REVIEW IS INTENDED ONLY FOR GENERAL CONFORMANCE
TO THE DESIGN CONCEPT AND CONSTRUCTION DOCUMENTS.
SD-6. SHOP DRAWINGS WILL BE RETURNED FOR RESUBMITTAL IF MAJOR ERRORS
ARE FOUND DURING REVIEW.
SD-7. ALLOW A MINIMUM OF (10) WORKING DAYS FOR REVIEW OF SHOP DRAWINGS
BY THE STRUCTURAL ENGINEER.
COLD FORMED STEEL FRAMING NOTES
CF-1. COLD FORMED STEEL WORK SHALL CONFORM TO THE 2015 OR LATER
ADDITION AS REFERENCED BY THE 2018 IBC (INCLUDING ALL APPLICABLE
SUPPLEMENTS AND STANDARDS) OF AISI'S "NORTH AMERICAN SPECIFICATION
OF FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS"
CF-2. REFER TO SPECIFICATIONS FOR COLD FORMED METAL FRAMING MATERIAL
PROPERTIES AND OTHER GENERAL REQUIREMENTS. COLD FORMED STEEL
SHALL BE GALVANIZED G-60 U.N.O.
CF-3. STUD, TRACK, AND OTHER APPLICABLE ROLLED SHAPES SHALL CONFORM
TO THE NOMENCLATURE AND DIMENSIONS SET FORTH BY THE STEEL STUD
MANUFACTURER'S ASSOCIATION (SSMA). REFER TO SSMA'S "PRODUCT
TECHNICAL INFORMATION" CATALOG AND ICC ER 4943P FOR MINIMUM
SECTION PROPERTIES AND DIMENSIONS.
CF-4. SCREWS FOR ATTACHING COLD FORMED STEEL TO COLD FORMED STEEL
SHALL BE CORROSION RESISTANT, SELF DRILLING, SELF TAPPING, #8 OR
#10 AS INDICATED, PAN OR HEX HEAD, WITH LENGTH, POINT STYLE AND
INSTALLATION METHOD IN ACCORDANCE WITH MANUFACTURERS
INSTRUCTIONS. PROVIDE 3/4" MINIMUM SPACING BETWEEN SCREWS AND
3/4" MINIMUM EDGE DISTANCE U.N.O.
CF-5. ALL CONNECTIONS SHALL HAVE AT LEAST (2) #8 SCREWS U.N.O.
CF-6. FASTENERS FROM COLD FORMED STEEL TO STRUCTURAL STEEL OR
CONCRETE SHALL BE 0.157" DIAMETER POWDER DRIVEN FASTENERS "SHOT
PINS" UNLESS OTHERWISE NOTED. PROVIDE 1" MINIMUM EMBEDMENT INTO
CONCRETE WITH WASHERS PER MANUFACTURER, U.N.O. SIZE LENGTH OF
SHOT PINS AS REQUIRED BY MANUFACTURER'S ICC ES REPORT FOR
ATTACHMENT TO STRUCTURAL STEEL. MANUFACTURER'S EDGE DISTANCE
AND SPACING REQUIREMENTS SHALL BE MET AND VERIFIED BY THE
CONTRACTOR IN THE FIELD.
CF-7. WALL TRACKS AND ACCESSORIES SHALL BE THE SAME GAUGE AND WIDTH
AS THE STUDS, U.N.O.
CF-8. PROVIDE SUFFICIENT STUDS AND BLOCKING/BACKING AT ALL GRAB BARS
AND WALL HUNG EQUIPMENT, MONITORS, CABINETS, TOILET ACCESSORIES,
ETC.
DELEGATED DESIGN SUBMITTALS
DOCUMENTS FOR DELEGATED DESIGN SUBMITTAL ITEMS SHALL BE REVIEWED BY
THE ENGINEER OF RECORD IN RESPONSIBLE CHARGE WHO SHALL FORWARD
THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THEY HAVE
BEEN REVIEWED AND ARE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE
BUILDING.
DS-1. ANCHORAGE AND BRACING REQUIREMENTS FOR MECHANICAL, HVAC,
PLUMBING, PROCESS AND ELECTRICAL EQUIPMENT INCLUDING FLOOR
AND ROOF SUPPORTED EQUIPMENT.
DS-2. COLD FORMED STEEL FRAMING - SPECIFICATION SECTION 054000
COLD FORMED TRUSS FRAMING
CT-1. PROVIDE BLOCKING BETWEEN TRUSSES LOCATED OVER MASONRY
SHEAR WALLS TO RESIST THE LOADS SHOWN ON ROOF FRAMING PLANS
AND S-001, DESIGN OF STRAP BLOCKING PER TRUSS MANUFACTURER,
REFER TO ROOF FRAMING DETAILS FOR CHORD / COLLECTOR REQUIRED
OVER ALL EXTERIOR WALLS.
CT-2. ALL COLD FORMED STEEL TRUSS AND FRAMING SHALL BE DESIGNED BY THE
MANUFACTURER. SEE MANUFACTURER'S CALCULATIONS FOR
INFORMATION NOT INCLUDED IN THESE DRAWINGS.
CT-3. TRUSS MANUFACTURER TO VERIFY ALL DIMENSIONS FROM FLOOR
PLANS AND FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION
OF TRUSSES.
CT-4. TRUSS MANUFACTURER SHALL PROVIDE A COMPLETE SYSTEM,
INCLUDING ALL MISCELLANEOUS ITEMS REQUIRED TO COMPLETE
THE SYSTEM. THIS INCLUDES PROVIDING DOUBLE, TRIPLE, OR
GREATER NUMBER OF COMBINED TRUSSES AS REQUIRED TO
SUPPORT ALL REQUIRED LOADING.
CT-5. TRUSS MANUFACTURER TO PROVIDE ALL TEMPORARY AND PERMANENT
BRIDGING, BRACING, SPECIAL TRUSS CLIPS, ALL TRUSS TO BEARING
CONNECTIONS, AND ALL TRUSS TO TRUSS/GIRDER CONNECTIONS.
CT-6. PERMANENT BRACING AND TEMPORARY INSTALLATION RESTRAINT/BRACING
ARE TO BE DESIGNED BY TRUSS MANUFACTURER.
CT-7. DIAPHRAGM DESIGN AND DECK UPLIFT CALCULATIONS HAVE ASSUMED 20
GAUGE GRADE 33 TOP CHORDS.
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.:
1005 River Street Port Huron, MI 48060 phone: 810-956-9300 fax: 810-956-9281
/1 /2
:0
:1
P M
C R e v it L o c a l\
.0
-S
-R
D e v ik a .D e M a ri o n
.r v t
F L
O R
ID
A
A
IR
N A
T
IO
N A
L G
U A
R D
S R
W
S
T A
R K
E
F L
S-002
4363500-171034.01
DND
JAL
STRUCTURAL NOTES
R E
P A
IR
B
A S
E E
N G
IN
E
E R
IN
G
A D
M
IN
S
H O
P S
B
L D
G
November 19, 2021
DRM
STATEMENT OF
SPECIAL INSPECTION AND TESTING
TI-1. THE CONTRACTOR SHALL RETAIN THE SERVICES OF ONE OF MORE
APPROVED AGENCIES TO PROVIDE SPECIAL INSPECTIONS AND TESTS DURING
CONSTRUCTION ON THE TYPES OF WORK SPECIFIED IN SECTION 1705 AND
IDENTIFY THE APPROVED AGENCIES TO THE AHJ. THESE SPECIAL
INSPECTIONS AND TESTS ARE IN ADDITION TO THE INSPECTIONS BY THE
CONTRACTOR THAT ARE IDENTIFIED IN SECTION 110.
TI-2. THE SIA SHALL BE INDEPENDENT FROM THE CONTRACTOR RESPONSIBLE
FOR THE WORK BEING INSPECTED. SPECIAL INSPECTION AND TESTING
SHALL BE DONE BY APPROVED, QUALIFIED PERSONNEL SATISFACTORY
TO THE AUTHORITY HAVING JURISDICTION.
TI-3. REFER TO PROJECT SPECIFICATIONS FOR COST RESPONSIBILITY OF SPECIAL
INSPECTION AND TESTING.
TI-4. SPECIAL INSPECTION AND TESTING DOES NOT REPLACE CODE-REQUIRED
INSPECTIONS OR STRUCTURAL OBSERVATIONS.
TI-5. CONTRACTOR’S RESPONSIBILITY:
A. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT ALL STRUCTURAL
WORK FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS.
ANY INSPECTION PROVIDED BY OTHERS DOES NOT RELIEVE THE
CONTRACTOR OF THIS RESPONSIBILITY. ANY DEVIATIONS FROM THE
CONTRACT DOCUMENTS THAT ARE FOUND AT A LATER DATE AND ARE
DECLARED TO BE SIGNIFICANT BY THE STRUCTURAL ENGINEER SHALL
BE CORRECTED BY THE CONTRACTOR WITHOUT COST OR ANY DELAY
TO THE PROJECT SCHEDULE.
B. THE CONTRACTOR SHALL PROVIDE THE SIA ACCESS TO ALL PLACES
WHERE THE WORK IS BEING PERFORMED. A MINIMUM OF 24 HOURS
NOTIFICATION SHALL BE GIVEN TO THE SIA AND DESIGN PROFESSIONAL
PRIOR TO THE COMMENCEMENT OF WORK REQUIRING TESTING OR
INSPECTION. THE WORK FOR WHICH SPECIAL INSPECTION IS REQUIRED
SHALL REMAIN ACCESSIBLE AND EXPOSED FOR SPECIAL INSPECTION
PURPOSES UNTIL COMPLETION OF THE REQUIRED SPECIAL INSPECTIONS.
C. TEMPORARY CONSTRUCTION AND SITE SAFETY ARE THE RESPONSIBILITY
OF THE CONTRACTOR. THE SIA IS NOT INSPECTING FOR O.S.H.A.
COMPLIANCE OR REQUIRED TO INSPECT TEMPORARY CONSTRUCTION,
SUCH AS TEMPORARY BRACING OR SHORING.
D. EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A
MAIN WIND OR SEISMIC FORCE RESISTING SYSTEM OR COMPONENT
LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS SHALL SUBMIT A
WRITTEN STATEMENT OF RESPONSIBILITY TO THE AUTHORITY HAVING
JURISDICTION (BUILDING OFFICIAL) AND THE OWNER PRIOR TO THE
COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE
CONTRACTOR’S STATEMENT OF RESPONSIBILITY SHALL CONTAIN
ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS
CONTAINED IN THE STATEMENT OF SPECIAL INSPECTION.
E. STRUCTURAL STEEL: THE CONTRACTOR AND SUBCONTRACTOR(S)
RESPONSIBLE FOR ERECTION AND FABRICATION SHALL BE RESPONSIBLE
FOR QUALITY CONTROL INSPECTORS (QCI) IN ACCORDANCE WITH AISC
360 AND AISC 341. REFER TO STRUCTURAL STEEL TESTING AND
INSPECTION NOTES.
TI-6. THE SIA IS NOT AUTHORIZED TO DIRECT OR APPROVE ANY CHANGES FROM
THE CONTRACT DOCUMENTS. IF THE CONTRACTOR WISHES TO QUESTION
THE
SIA'S INTERPRETATION OF THE CONTRACT DOCUMENTS, HE MAY DO SO WITH
THE OWNER ASSISTED BY THE DESIGN PROFESSIONAL.
TI-7. THE SIA IS NOT AUTHORIZED TO STOP OR DELAY THE WORK. IF THE
CONTRACTOR ELECTS TO CONTINUE WITH A CERTAIN PORTION OF WORK
AFTER BEING NOTIFIED BY THE SIA THAT SUCH WORK IS NOT IN ACCORDANCE
WITH THE CONSTRUCTION DOCUMENTS, THE CONTRACTOR DOES SO AT
THEIR OWN RISK AND MAY BE REQUIRED TO CORRECT THE WORK AT A
LATER DATE.
TI-8. THESE NOTES AND THE PROJECT SPECIFICATIONS TYPICALLY INDICATE THE
FREQUENCY OF TESTING AND SPECIAL INSPECTIONS. WHERE THE
FREQUENCY IS NOT INDICATED, THE SIA SHALL SUBMIT A PROPOSAL OF
SPECIAL INSPECTION AND TESTING INTERVALS TO THE OWNER.
TI-9. THE SIA SHALL ISSUE ONGOING REPORTS OF INSPECTIONS AND TESTS TO
THE CONTRACTOR AND DESIGN PROFESSIONAL.
TI-10. THE SIA SHALL KEEP REPORTS OF EACH INSPECTION AND TESTING ACTIVITY.
REPORTS SHALL INDICATE WHETHER THE WORK WAS IN COMPLIANCE WITH
THE APPROVED CONSTRUCTION DOCUMENTS. DEFICIENCIES SHALL BE
BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR
CORRECTION. IF THEY ARE NOT CORRECTED, THE DISCREPANCIES SHALL
BE BROUGHT TO THE ATTENTION OF THE AUTHORITY HAVING JURISDICTION
(BUILDING OFFICIAL) AND DESIGN PROFESSIONAL PRIOR TO THE COMPLETION
OF THAT PHASE OF THE WORK.
TI-11. THE SIA SHALL PREPARE AND SUBMIT A FINAL REPORT DOCUMENTING
REQUIRED SPECIAL INSPECTIONS AND CORRECTION OF ANY DISCREPANCIES
NOTED IN THE INSPECTIONS SHALL BE SUBMITTED AT A POINT IN TIME
AGREED UPON PRIOR TO THE START OF WORK BY THE APPLICANT AND THE
BUILDING OFFICIAL.
TI-12. FABRICATOR SPECIAL INSPECTIONS: UNLESS OTHERWISE APPROVED,
SPECIAL INSPECTIONS SHALL BE PERFORMED FOR WORK AT FABRICATION
SHOPS. SPECIAL INSPECTIONS AT THE FABRICATION SHOP BY THE SIA COULD
BE WAIVED BY THE OWNER IF THE FABRICATION SHOP IS REGISTERED AND
APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION IN
ACCORDANCE WITH CODE (1704.2.5.2). APPROVAL SHALL BE EVALUATED
BY THE SIA AND ESTABLISHED WITH THE OWNER PRIOR TO FABRICATION.
THE FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE
OWNER AND BUILDING OFFICIAL IN ACCORDANCE WITH CODE (1704.5.2)
STATING THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH THE
APPROVED CONSTRUCTION DOCUMENTS. THE OWNER AND SIA RESERVE
THE RIGHT TO INSPECT THE WORK AT THE FABRICATION SHOP REGARDLESS
OF FABRICATOR QUALIFICATIONS / CERTIFICATIONS.
TI-13. STRUCTURAL SPECIAL INSPECTION AND TESTING BY THE SIA SHALL INCLUDE
SCOPE LISTED IN TABLE 1. WHERE PROJECT GEOTECHNICAL ENGINEER IS
INDICATED, THE ENGINEER RESPONSIBLE FOR THE SOILS REPORT RELIED
ON FOR DESIGN, OR HIS DESIGNEE, SHALL PERFORM THE INSPECTIONS AND
TESTING.
TI-14. REFER TO STRUCTURAL STEEL SPECIAL INSPECTION NOTES FOR
STRUCTURAL STEEL AND STEEL ELEMENTS SIMILAR TO STRUCTURAL STEEL.
FOR PEMB STRUCTURAL SYSTEM AND OTHER NON-PEMB STEEL
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.:
1005 River Street Port Huron, MI 48060 phone: 810-956-9300 fax: 810-956-9281
/1 /2
:0
:1
P M
C R e v it L o c a l\
.0
-S
-R
D e v ik a .D e M a ri o n
.r v t
F L
O R
ID
A
A
IR
N A
T
IO
N A
L G
U A
R D
S R
W
S
T A
R K
E
F L
S-005
4363500-171034.01
DND
JAL
STATEMENT OF
SPECIAL
INSPECTIONS AND
NOTES
R E
P A
IR
B
A S
E E
N G
IN
E
E R
IN
G
A D
M
IN
S
H O
P S
B
L D
G
November 19, 2021
DRM
11/19/21 B-3 SUBMITTAL
INSPECTION OF POST-INSTALLED ADHESIVE ANCHORS
(INCLUDING ANCHORS W/ SUSTAINED TENSION AND
UPWARDLY INCLINED ANCHORS); VERIFICATION OF
INSTALLER CERTIFICATION; VERIFICATION OF
APPROVED RESEARCH REPORT ACI 355.2
PREQUALIFIED
X
INSPECT IN ACCORDANCE WITH APPROVED
RESEARCH REPORT (CONTINUOUS - DO NOT
LOWER INSPECTION FREQUENCY)
TABLE 1705.3 (4) /
ACI 318 3.2.2, 17.8, 26.7, 26.13
INSPECTION OF POST-INSTALLED MECHANICAL
ANCHORS; VERIFICATION OF APPROVED RESEARCH
REPORT ACI 355.2 PREQUALIFIED
X
INSPECT IN ACCORDANCE WITH APPROVED
RESEARCH REPORT
TABLE 1705.3 (3) /
ACI 318 3.2.2, 17.8, 26.7, 26.13
CONTIN-
UOUS
PERI-
ODIC
(SEE
SPECS)
(IBC 2018 UNO)
CONCRETE POST-INSTALLED ANCHORS
SPECIAL INSPECTION TESTING
COMMENTS
CODE / STANDARD REF.
INSPECTION AND TESTING OF CONCRETE ON
COMPOSITE METAL DECK OR FORM DECK
FOLLOW ALL REQUIREMENTS LISTED FOR CAST-IN-PLACE CONCRETE.
FOR COMPOSITE DECK COORDINATE WITH STEEL SPECIAL INSPECTION
AND TESTING REQUIREMENTS
TABLE 1705.3 /
AISC 360
VERIFICATION OF IN-SITU CONCRETE STRENGTH PRIOR
TO REMOVAL OF SHORES OR FORMS FROM BEAMS
AND STRUCTURAL SLABS.
X
NOT REQUIRED AT FOOTINGS, SLABS ON GRADE
OR OTHER GROUND SUPPORTED CONCRETE
TABLE 1705.3 (11) /
ACI 318 26.11.2
VERIFICATION OF PROTECTION FROM THE ADVERSE
EFFECTS OF WEATHER, HEATING EQUIPMENT,
WELDING AND OTHER POTENTIALLY HARMFUL
CONDITIONS.
X ACI 318, ACI 305, ACI 306
INSPECTION OF FOR MAINTENANCE OF SPECIFIED
CURING TEMPERATURE AND TECHNIQUES
X
TABLE 1705.3 (8), 1908.9 /
ACI 318: 26.5.3-26.5.5
COMPRESSIVE STRENGTH TESTING X
TABLE 1705.3 (6), 1908.10 /
ACI 318: 26.12.1.1
INSPECTION OF CONCRETE PLACEMENT FOR PROPER
APPLICATION / CONSOLIDATION
X
TABLE 1705.3 (7), 1908.6,
1908.7, 1908.8 / ACI 318: 26.5
PLACEMENT -TESTING FOR SLUMP, AIR CONTENT,
TEMPERATURE AT TIME WHEN STRENGTH SAMPLES
ARE MADE
X X
TABLE 1705.3 (6), 1908.10 /
ASTM C172, ASTM C31 /
ACI 318: 26.4, 26.5, 26.12
PLACEMENT – VERIFICATION OF REQUIRED DESIGN MIX X
VERIFY PRIOR TO DEPOSITING. NOTE ADDITIVES
(ADMIXTURES, WATER, ETC) ADDED PRIOR TO
PLACEMENT
TABLE 1705.3 (5), 1904.1,
1904.2, 1908.2, 1908.3 /
ACI 318: CH.19, 26.4.3, 26.4.4
PRE-PLACEMENT INSPECTION OF FORMWORK FOR
SHAPE, LOCATION, DIMENSIONS
X
TABLE 1705.3 (12) /
ACI 318: 26.11.1.2(b)
PRE-PLACEMENT INSPECTION OF CAST-IN-PLACE
ANCHORS AND EMBEDS
X
COORDINATE WITH STEEL INSPECTION
REQUIREMENTS
TABLE 1705.3 (3) / ACI 318:
17.8.2, 20.5, 20.7, 26.7, 26.8
CONTIN-
UOUS
PERI-
ODIC
(SEE
SPECS)
(IBC 2018 UNO)
CONCRETE
SPECIAL INSPECTION TESTING
COMMENTS
CODE / STANDARD REF.
SHEAR REINFORCEMENT (STIRRUPS, TIES, SPIRALS) X ACI 318: CH20, 25.2, 25.3, 25.7
C) INSPECT ALL OTHER WELDS X
B) INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16
IN.
X
A) VERIFY WELDABILITY OF REINFORCING BARS OTHER
THAN ASTM A706
X CONFIRM WITH MILL CERTIFICATE
REINFORCING BAR WELDING:
TABLE 1705.3 (2) / AWS D1.4 /
ACI 318 26.6.4
VERIFICATION OF A706 STEEL FOR WELDED
REINFORCEMENT
X CONFIRM WITH MILL CERTIFICATE
TABLE 1705.3 (2) / AWS D1.4 /
ACI 318 26.6.4
INSPECTION OF REINFORCING STEEL AND PLACEMENT X
TABLE 1705.3 (1), 1908.4 /
ACI 318: CH 20, 25.2-25.3,
26.6.1-26.6.3
CONTIN-
UOUS
PERI-
ODIC
(SEE
SPECS)
(IBC 2018 UNO)
CONCRETE REINFORCEMENT
SPECIAL INSPECTION TESTING
COMMENTS
CODE / STANDARD REF.
VERIFICATION THAT UNDERSLAB BASE MATERIALS
HAVE BEEN PROPERLY PLACED AND COMPACTED
X X TABLE 1705.6 (4)
VERIFICATION THAT FOOTING EXCAVATION EXTENDS
TO PROPER DEPTH AND HAVE REACHED PROPER
MATERIAL
X X TABLE 1705.6 (2)
PRIOR TO PLACEMENT OF COMPACTED FILL,
OBSERVATION OF SUBGRADE AT BOTTOM OF
OVER-EXCAVATION, AND VERIFY THAT SITE HAS BEEN
PREPARED PROPERLY
X X TABLE 1705.6 (5)
VERIFICATION OF USE OF PROPER MATERIALS,
DENSITIES AND LIFT THICKNESSES DURING
PLACEMENT AND COMPACTION OF COMPACTED FILL.
X X TABLE 1705.6 (4)
CLASSIFICATION AND TESTING OF COMPACTED FILL
MATERIALS
X X TABLE 1705.6 (3)
VERIFICATION THAT OVER-EXCAVATION EXTENDS TO
PROPER DEPTH, HAS REACHED PROPER MATERIAL,
AND HAS EXTENDED TO PROPER HORIZONTAL
EXTENTS
X X TABLE 1705.6 (2)
VERIFICATION OF MATERIALS BELOW FOOTINGS ARE
ADEQUATE TO ACHIEVE THE DESIGN BEARING
CAPACITY
X X TABLE 1705.6 (1)
CONTIN-
UOUS
PERI-
ODIC
(SEE
SPECS)
(IBC 2018 UNO)
SOILS
SPECIAL INSPECTION TESTING
COMMENTS
CODE / STANDARD REF.
TABLE 1: SPECIAL INSPECTION AND TESTING
B. WORK PERFORMED ON THE PREMISES OF A FABRICATOR APPROVED BY THE BUILDING OFFICIAL PER SECTION 1704.2.5 OF CHAPTER 17 OF THE 2018 INTERNATIONAL BUILDING CODE NEED NOT BE TESTED AND INSPECTED PER THE TABLE ABOVE. THE FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE THAT THE WORK HAS BEEN PERFORMED IN ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS TO THE BUILDING OFFICIAL AND THE ARCHITECT AND ENGINEER OF RECORD.
A. REFER TO SPECIFICATIONS FOR TESTING REQUIREMENTS AND ADDITIONAL QUALITY ASSURANCE REQUIREMENTS.
TABLE NOTES:
SPRAYED, MASTIC, INTUMESCENT, PENETRATIONS AND
JOINTS
NOT COVERED IN THIS TABLE.
REFER TO FIRE PROTECTION DRAWINGS AND CODE REQUIREMENTS
1705.14, 1705.15, 1705.16, 1705.17
CONTIN-
UOUS
PERI-
ODIC
(SEE
SPECS)
(IBC 2018 UNO)
FIRE PROTECTION
SPECIAL INSPECTION TESTING
COMMENTS
CODE / STANDARD REF.
INSPECTION OF VIBRATION ISOLATION SYSTEMS X 1705.12.6 (5)
INSPECTION AND VERIFICATION OF SUPPORTS,
ATTACHMENTS AND SEISMIC BRACING. VERIFICATION
OF RESTRAINT ELEMENTS MEET PROJECT
REQUIREMENTS.
X
NOT REQUIRED FOR ITEMS UNDER 20 LBS. OR
LESS IN ANY LOCATION; NOT REQUIRED FOR
FLOOR-SUPPORTED ITEMS 400 LBS OR LESS AND
HAVING CENTER OF GRAVITY 4 FT. OR LESS
ABOVE FLOOR.
1705.12.6 (2), 1705.12.6 (3),
1705.12.6 (4) /
ASCE 7-16 13.2.1 /
ASCE 7-16 TABLE 13.2-1
INSPECTION OF SEISMIC ANCHORAGE FOR
EMERGENCY AND STANDBY POWER SYSTEMS
X 1705.12.6 (1)
CONTIN-
UOUS
PERI-
ODIC
(SEE
SPECS)
(IBC 2018 UNO)
MECHANICAL/ ELECTRICAL COMPONENTS
SPECIAL INSPECTION TESTING
COMMENTS
CODE / STANDARD REF.
VERIFICATION OF PROPER ERECTION AND FASTENING
FOR EXTERIOR CLADDING, INTERIOR NON-BEARING
WALLS AND EXTERIOR VENEER
X
NOT REQUIRED FOR WALLS AND VENEER 30 FEET
OR LESS IN HEIGHT ABOVE GRADE OR WALKING
SURFACE; NOTE REQUIRED FOR CLADDING AND
VENEER SYSTEMS 5 PSF OR LESS; NOT
REQUIRED FOR INTERIOR NON-BEARING WALL
SYSTEM 15 PSF OR LESS
1705.12.5 /
ASCE 7-16 13.2.1 /
ASCE 7-16 TABLE 13.2-1
CONTIN-
UOUS
PERI-
ODIC
(SEE
SPECS)
(IBC 2018 UNO)
ARCHITECTURAL ELEMENTS…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .