Att 10 Heeling Moment Calculation 17Sep2020.xlsx
XLSX spreadsheet 83 KB Posted
- Attached to
- Workboat Docking
- Solicitation number
- N00024-21-R-2250
About this file
This document contains a draft solicitation from the Naval Sea Systems Command for workboat docking services. The solicitation is identified as N00024-21-R-2250 and seeks to procure docking services for the U.S. Navy Harbor Security Boat. The draft solicitation and accompanying attachments are being shared with industry to allow for review, questions, and feedback prior to a formal RFP being issued. Feedback may be directed to the contracting officer and specialist listed. This draft is for informational planning purposes only and does not represent a final procurement commitment by the government.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Att 1 WBD CNRNW Spec 10Dec2020.pdf | ||
| Att 3 - WBD Vendor Provided Spare Parts List.xlsx | XLSX spreadsheet | |
| Att_4_-_Delivery Schedule.XLS | XLS spreadsheet | |
| Att_8_-_CLIN Pricing Chart.xls | XLS spreadsheet | |
| Att_6_-_Unique_Item_Identification_(UID).doc | DOC document | |
| Att_5_- Technical Data Rights Assertion.doc | DOC document | |
| DRAFT N0002421R2250 Workboat Docking.pdf | ||
| Att 2 WBD Specification Response Matrix 7Dec2020.xlsx | XLSX spreadsheet | |
| Ref e_Att_1_WBD_CNRNW_Spec_DRAFT_for TWH review_12Nov2020.docx | DOCX document | |
| Att_7_-_Warranty Terms.doc | DOC document | |
| Att 11 - Past_Performance_Questionnaire.doc | DOC document | |
| Attachment Index.docx | DOCX document | |
| Att_9_-_Past_Performance_Information.doc | DOC document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FBD Force Calc
| Heeling Moment Calculation for Intact Stabiliy Guidelines for Towing Vessels [ABS Part 5, Chapter 11, Appendix 1 ] | ||||
| Inputs | Value | Unit | Notes | |
| T | 6000 | lbs | ||
| Tf | 80% | Thrust factor from Specification (Section 079) | ||
| F | 4800 | lbs | = T * F | |
| theta | deg | Angle of Towline from H-Bitt to Deck Chock | ||
| H | ft | Distance from LCB to top of H-Bitt | ||
| V | ft | Transverse Distance from CL to H-Bitt | ||
| Hd | ft | Height of Towline from LCB after Deck Chock | ||
| Vd | ft | Transverse Distance from CL to Deck Chock |
| Force Calcs | |||
| F' | 4,800 | lbs | = F / COS (ϴ) |
| F'h | 4,800 | lbs | = F * COS (ϴ) |
| F'v | 0 | lbs | = F * SIN (ϴ) |
| Mv | 0 | ft-lbs | = (F'v * V) - (F'v *Vd) |
| Mh | 0 | ft-lbs | = (F'h * H) + (F'h * Vd) - (F'h * Vd) |
HMMT 0 ft-lbs = Mv + Mh image1.png