ATT 10- Facility-CLIN Assignment Sheet.xlsx

XLSX spreadsheet 21 KB Posted

Attached to
Hazardous Waste Removal and Disposal at Camp Pendleton, CA Federal contract opportunity
Solicitation number
SP450020R0019
Issued by
Defense Logistics Agency

View the file

Other files for this federal contract opportunity

Other files attached to Hazardous Waste Removal and Disposal at Camp Pendleton, CA, newest first.
File Type Posted
ATT 1- Camp Pendleton PS AFFF CLINs 7.9.2020.xlsx XLSX spreadsheet
ATT 1- Camp Pendleton PS AFFF CLINs 7.6.2020.xlsx XLSX spreadsheet
Pendleton Solicitation Questions 07.06.2020.docx DOCX document
ATT 1- Camp Pendleton PS AFFF CLINs 7.6.2020.xlsx XLSX spreadsheet
ATT 1 - Camp Pendleton PS 6.26.20.xlsx XLSX spreadsheet
ATT 1 - Camp Pendleton PS 6.26.20.xlsx XLSX spreadsheet
ATT 16- UPDATED Master CLIN Catalog 6.19.2020.xlsx XLSX spreadsheet
ATT 1- UPDATED Camp Pendleton Price Schedule 6.19.2020.xlsx XLSX spreadsheet
ATT 1- Camp Pendleton PS 6.4.2020.xlsx XLSX spreadsheet
ATT 1- Camp Pendleton PS 6.3.2020.xlsx XLSX spreadsheet
Contractor Questions 6.2.2020.pdf PDF
Responses to Questions 5.22.2020.docx DOCX document
ATT 15- 16D06 ERS EB Waste Disposal Tracking Detail.xls XLS spreadsheet
ATT 1- Camp Pendleton Price Schedule 5.22.20.xlsx XLSX spreadsheet
ATT 16- Master CLIN Catalog 27 Jan 2020.xlsx XLSX spreadsheet
ATT 11- Updated 30 Month Ordering History- SP450016D0006.xls XLS spreadsheet
Responses to Questions 5.12.2020.docx DOCX document
ATT 7- RejectedCylinders.pdf PDF
ATT 6- DISP_CylinderReferenceList_150701.xlsx XLSX spreadsheet
ATT 8- DL2511.pdf PDF
ATT 13- KTR Work Surveillance Checklist - Placement or Removal Empty ROB or Vac Box.pdf PDF
ATT 3- Certificate_of_Recycling.doc DOC document
ATT 1- Camp Pendleton Price Schedule.xlsx XLSX spreadsheet
ATT 4- WD 1996-0223 2.26.2020.pdf PDF
ATT 5- Compressed_Gas_Cylinders.doc DOC document
Solicitation SP450020R0019.pdf PDF
ATT 2-DL2505.pdf PDF
ATT 12- Pendleton Pick up Points.docx DOCX document
ATT 9- PPI Offeror Questionnaire Pendleton.pdf PDF
ATT 11- 30 Month Order Summary Pendleton.rtf RTF text file
ATT 14- KTR Work Surveillance Checklist - ICS Work.pdf PDF
Show all 31

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Facility CLIN Assignment Sheet

Master Facility - CLIN Assignment Sheet
Base
CLINWaste DescriptionPlease use these columns to identify the EPA ID # (or Name/City/State for Non-RCRA) of all facility(s) that will (or may) receive wastes associated with these Base CLINs. Includes all interim and downstream facilities.
BA01Alkaline Batteries, Managed as Universal Waste (UW) for Recycling or Direct Landfill Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002.

BA02 Calcium Chromate (CaCrO4) Thermal Batteries, Deactivated, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D001 (Oxidizer), D003-11.

BA03 Carbon-Zinc (CZn) Batteries, Managed as UW/HW for Recycling or Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

BA04 Lead Acid Batteries, Managed as UW/HW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: D002, D004-11.

BA05 Lithium Ion (Li-Ion) Batteries, Managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: Universal waste, D002-11.

BA06 Lithium Iron Sulfide (Li2FeS2) Thermal Batteries, Deactivated, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002-11.

BA07 Lithium Manganese (LiMn and Oxides thereof) Batteries, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: D002-11.

BA08 Lithium Sulfur Dioxide (LiSO2) Batteries, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002-11.

BA09 Lithium Thionyl Chloride (LiSCl) Batteries, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002-11.

BA10 Lithium Batteries, Mixed Types, Deactivated if Applicable, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002-11.

BA11 Magnesium (Mg) Batteries, Managed as UW/HW for Recycling or Destruction and Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

BA12 Mercury (Hg) Batteries, Managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

BA13 Nickel Metal Hydride (NiMh) Batteries, Managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

BA14 Nickel-Cadmium (NiCd) Batteries, Managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

BA15 Silver-Zinc (AgZn) and Zinc Silver Oxidizeride (ZnAgO) Batteries, Managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

CS01 Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.

CS02 Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, >1% Total Metals, Cr+6 <100 ppm.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.

CS03 Corrosive Acids, Inorganic other than HF and HNO3, Concentrated, <1% Total Metals, Cr+6 <100 ppm.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.

CS04 Corrosive Acids, Chromic (H2Cr04 ), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11.

CS05 Corrosive Acids, Chromic (H2Cr04 ), 1-10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11.

CS06 Corrosive Acids, Chromic (H2Cr04), >10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11.

CS07 Corrosive Acids, Chromic (H2Cr04 ), >100 ppm Cr+6, F-Listed Liquids, Solids, Sludges, Debris.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, U032, F-Listed.

CS08 Corrosive Acids, Hydrofluoric (HF) and Nitric (HNO3), <50% in Water, <1% Total Metals, Cr+6 <100 ppm.

● Physical State: Liquid

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, Listed Inorganics.

CS09 Corrosive Acids, Hydrofluoric (HF) and Nitric (HNO3), >50% in Water, <1% Total Metals, Cr+6 <100 ppm.

● Physical State: Liquid

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, Listed Inorganics.

CS10 Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.

CS11 Corrosive Alkalines, Inorganic, <50% in Water, >1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.

CS12 Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/ Sludges/Solids/Debris, Non-Flammable.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, Listed.

CS13 Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, Non-Flammable.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, Listed.

CS14 Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, Listed.

CS15 Corrosive Aerosols, Non-Flammable.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, Listed.

CS99 Military Items for Demil, Corrosive, Inorganic Acids or Bases with Debris and possible Free Liquids, Non-Flammable, i.e. CDE kits, loosepacks. Certificate of Disposal/Destruction Required.

● Permissible Waste Codes: D002, D004-11, Listed.

CY01 Cylinders, Category 1, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY02 Cylinders, Category 2, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY03 Cylinders, Category 3, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY04 Cylinders, Category 4, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY05 Cylinders, Category 5, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY06 Cylinders, Category 6, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY07 Cylinders, Category 7, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY08 Cylinders, Category 8, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY09 Cylinders, Acetylene, Contains Asbestos, for Purge and Landfill. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.

CY10 Cylinders, Acetylene, for Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.

CY11 Cylinders, Propane, 20-Lb "Grill Size", for Disposal/Recycle/Reuse. Typically 13" x 17". "ME" = 1 EA Grill-Size Cylinder.

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.

CY12 Cartridges, Flammable Gas, AVGAS, Gas/Diesel Starting, for Disposal/Recycle. Diameter up to 3", Length up to 10".

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.

CY13 Cartridges, Inert Gas, for Disposal/Recycle/Reuse. Diameter up to 1", Length up to 6". "ME" = 1 EA Cartridge.

● Physical State: Comp. Gas

● Permissible Waste Codes: N/A.

FL01 Flammable Aerosols, Non-Foaming, No Isocyanates.

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL02 Flammable Debris, Contaminated with Common Solvents, Shreddable, No Free Liquids, No large metal, rock, or masonry components.

● Physical State: Solid

● Permissible Waste Codes: D001, D004-43, Listed.

FL03 Flammable Liquids/Solids/Sludges/Debris, i.e. tank sludge, lubricants, paint-related waste, adhesives, rags, filters, PPE.

● Physical State: Various

● Permissible Waste Codes: D001-2, D004-43, Listed.

FL04 Flammable Corrosive Liquids/Solids/Sludges/Debris/Aerosols.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed.

FL05 Flammable Liquids, Pumpable, Rich, >7,000 BTU/Lb, <5% Total Chlorine.

● Physical State: Liquid

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL06 Flammable Liquids, Pumpable, Lean, 2,500-7,000 BTU/Lb, <5% Total Chlorine.

● Physical State: Liquid

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL07 Flammable Liquids, Pumpable, Lean to Rich, >2,500 BTU/Lb, 5-10% Total Chlorine.

● Physical State: Liquid

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL08 Flammable Resuspendable Solids/Sludges, Rich, >7,000 BTU/Lb, <5% Total Chlorine.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL09 Flammable Resuspendable Solids/Sludges, Lean, 2,500-7,000 BTU/Lb, <5% Total Chlorine.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL10 Flammable Resuspendable Solids/Sludges, Lean to Rich, >2,500 BTU/Lb, 5-10% Total Chlorine.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL11 Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.

● Physical State: Liquid

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL12 Flammable Solids/Sludges, Highly Chlorinated (>10%), Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL13 Oxidizers, Non-Reactive, other than chromic acid (see Corrosives), Liquids/Sludges/Solids/Debris.

● Physical State: Various

● Permissible Waste Codes: D001(Oxidizer), D002, D004-43, Listed.

FL14 Paints, Loose-Packed, Latex and/or Oil-Based, and Paint-Related Materials, >2,500 BTU/Lb (See Base CLIN NR06 for 100% Latex).

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL15 Water Contaminated with Solvents, Pumpable, <2,500 BTU/Lb.

● Physical State: Liquid

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL99 Military Items, Demil-Required Flammable Solids/Liquids/Debris, i.e. CDE Kits, Vials, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed.

LP01 Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, Listed Corrosives.

LP02 Lab Packs/Loose Packs, Mercury, Elemental Liquid.

● Physical State: Various

● Permissible Waste Codes: D004-11, Listed Inorganics.

LP03 Lap Packs/Loose Packs, Flammables other than Paints.

● Physical State: Various

● Permissible Waste Codes: D001-2, D004-43, Listed Flammables.

LP04 Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, other than paints, including pharmaceuticals.

● Physical State: Various

● Permissible Waste Codes: N/A.

LP05 Lab Packs/Loose Packs, Non-Reactive Oxidizers.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D004-11, Listed.

LP06 Lab Packs/Loose Packs, Reactive Oxidizers, Includes Organic Peroxides, Special Packaging Required.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D003-11, Listed.

LP07 Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, Includes Broken Sodium Lamps, Special Packaging Required.

● Physical State: Various

● Permissible Waste Codes: D001, D003-11, Listed.

LP08 Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, Special Packaging Required.

● Physical State: Various

● Permissible Waste Codes: D001-43, Listed.

LP09 Lab Packs/Loose Packs, Toxic Metals.

● Physical State: Various

● Permissible Waste Codes: D004-11, Listed Inorganics.

LP10 Lab Packs/Loose Packs, Toxic Organics.

● Physical State: Various

● Permissible Waste Codes: D004-43, Listed.

LP11 Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, including pharmaceuticals.

● Physical State: Various

● Permissible Waste Codes: D004-43, Listed.

LP12 Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals.

● Physical State: Various

● Permissible Waste Codes: D004-43, U-Listed Codes.

LP79 Lab Packs/Loose Packs, Flammables,Human Waste.

● Physical State: Various

● Permissible Waste Codes: D001-2, D004-43, Listed Flammables.

NR01 Non-RCRA Solids, Direct Landfill Ready (Subtitle D or Equivalent). No Free Liquids. Includes Non-PCB Drained/Dry Transformers, Ballasts, Capacitors, and Related Equipment.

● Physical State: Solid

● Permissible Waste Codes: N/A.

NR02 Non-RCRA Solids with Asbestos, Direct Landfill Ready (Subtitle D or Equivalent). Special Packaging Required. No Free Liquids.

● Physical State: Solid

● Permissible Waste Codes: N/A.

NR03 Non-RCRA Liquids, Pumpable, Aqueous (Water-Based).

● Physical State: Liquid

● Permissible Waste Codes: N/A.

NR04 Non-RCRA Liquids, Pumpable, Organic-Based.

● Physical State: Liquid

● Permissible Waste Codes: N/A.

NR05 Non-RCRA Liquids, Sludges, Solids and Debris with Free Liquids requiring solidification prior to landfill (subtitle D or equivalent). Includes Non-PCB Oil-Filled Transformers, Ballasts, Capacitors and Related Equipment.

● Physical State: Various

● Permissible Waste Codes: N/A.

NR06 Non-RCRA Loose-Packed Paints, 100% Water-Based (Latex).

● Physical State: Various

● Permissible Waste Codes: N/A.

NR07 Non-RCRA Pharmaceuticals for Thermal Destruction, Prescription and Non-Prescription. No DEA Restricted Meds. Certificate of Destruction Required.

● Physical State: Various

● Permissible Waste Codes: N/A.

NR08 Non-RCRA (RCRA-Empty) Containers, Metal & Plastic/Poly, Crushed, Recycle or Disposal.

● Physical State: Solid

● Permissible Waste Codes: N/A.

NR09 Non-RCRA (RCRA-Empty) Containers, Metal, Intact, Recycle or Disposal.

● Physical State: Solid

● Permissible Waste Codes: N/A.

NR10 Non-RCRA (RCRA-Empty) Containers, Plastic/Poly, Intact, Recycle or Disposal.

● Physical State: Solid

● Permissible Waste Codes: N/A.

NR11 Non-RCRA Combustible Solids for Waste-To-Energy (WTE) Disposal. May contain some free liquids.

● Physical State: Various

● Permissible Waste Codes: N/A.

NR12 Non-RCRA Solids containing DOE-Exempt NORM with radioactivity <2,000 pCi/g. ● Physical State: Solid

● Permissible Waste Codes: N/A.

NR91 Non-RCRA AFFF-Contaminated Solids/Sludges/Debris for RCRA Incineration, e.g., Soil, PPE, Filter Media. May contain some free liquids. Certificate of Disposal/ Destruction Required ● Physical State: Various

● Permissible Waste Codes: N/A.

NR92 Non-RCRA Liquids for RCRA Incineration, Pumpable, Unused AFFF. Certificate of Disposal/Destruction Required.

***Specifically for Navy added to Air Force AFFF contracts*** ● Physical State: Liquid

● Permissible Waste Codes: N/A.

NR93 Non-RCRA AFFF Concentrate Liquid for RCRA Incineration, Unused or >10% AFFF Product, Pumpable. Certificate of Disposal/Destruction Required. ● Physical State: Liquid

● Permissible Waste Codes: N/A.

NR94 Non-RCRA AFFF Rinsate/Water-Diluted Liquid for RCRA Incineration, Used or >90% Water, Pumpable. Certificate of Disposal/Destruction Required. ● Physical State: Liquid

● Permissible Waste Codes: N/A.

NR96 Non-RCRA Liquids, Pumpable, for RCRA Incineration. Certificate of Disposal/Destruction Required.

● Physical State: Liquid

● Permissible Waste Codes: N/A.

NR97 Non-RCRA Solids/Sludges/Debris, for RCRA Incineration. Certificate of Disposal/Destruction Required.

● Physical State: Various

● Permissible Waste Codes: N/A.

PC01 PCB and PCB/RCRA-Mixed Waste Contaminated with or Containing >5ppm Source, i.e. Debris, Sludge, Water, Leaking Capacitors, Fluids other than Transformer Mineral Oil. Certificate of Destruction Required. (2.1)

● Physical State: Various

● Permissible Waste Codes: Characteristic, Listed.

PC02 PCB Mineral Oil from Transformers, <5 ppm PCBs, Non-RCRA. (2.1)

● Physical State: Liquid

● Permissible Waste Codes: N/A.

PC03 PCB Mineral Oil from Transformers, 5-4,000 ppm PCBs. Non-RCRA, Certificate of Recycling or Destruction Required. (2.1)

● Physical State: Liquid

● Permissible Waste Codes: N/A.

PC04 PCB Mineral Oil , Water, Other Fluids, >4,000 ppm PCBs. Certificate of Destruction Required. (2.1)

● Physical State: Liquid

● Permissible Waste Codes: Characteristic, Listed.

PC05 PCB Oil-Filled Capacitors/Equipment other than Transformers, 1-49 ppm PCBs, Non-RCRA. (2.1)

● Physical State: Various

● Permissible Waste Codes: N/A.

PC06 PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, >5 ppm PCBs, Non-RCRA, Certificate of Recycling or Destruction Required. (2.1)

● Physical State: Various

● Permissible Waste Codes: N/A.

PC07 PCB Oil-Filled Transformers, <5 ppm PCBs, Non-RCRA. (2.1)

● Physical State: Various

● Permissible Waste Codes: N/A.

PC08 PCB Oil-Filled Transformers, >5 ppm PCBs. Certificate of Recycling or Destruction Required. (2.1)

● Physical State: Various

● Permissible Waste Codes: N/A.

PC09 PCB Solids/Debris Contaminated with <5 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-RCRA. (2.1)

● Physical State: Solid

● Permissible Waste Codes: N/A.

PC10 PCB Solids/Debris Contaminated with >5 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-RCRA. Certificate of Disposal, Recycling or Destruction Required. (2.1)

● Physical State: Solid

● Permissible Waste Codes: N/A.

PC11 PCB and Non-PCB Related ballast and other devices containing <5 ppm for Mandatory Recycling of recycable components. Certificate of Recycling Required. (See 2.1). ● Physical State: Solid

● Permissible Waste Codes: N/A.

PC12 PCB Related ballast and other devices containing ≥ 5 ppm for Mandatory Recycling of recycable components. Certificate of Recycling Required. (See 2.1). ● Physical State: Solid

● Permissible Waste Codes: N/A.

RE01 Lamps, Fluorescent, Intact, CFLs and <4 ft = Each (ME), U-Bent, Circulars and 4-6 ft Linears = Small (M1), 6-8 ft = Medium (M2), >8 ft = Large (M3).

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D004-11.

RE02 Lamps, Fluorescent, Crushed/Broken, with Filters.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D004-11.

RE03 Lamps, Halogen.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D004-11.

RE04 Lamps, High Intensity Discharge (HID).

● Physical State: Solid

● Permissible Waste Codes: Universal Waste D004-11.

RE05 Lamps, Mercury/Mercury Vapor.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste D004-11.

RE06 Lamps, Metal Halide and Metal Hydride, including Sodium.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste D003-11.

RE07 Mercury, High, COD Vials, Nessler's Reagent, Chemicals and Residues, Hg >260 mg/Kg.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, UW some states.

RE08 Mercury, High, Dental Amalgams & Residues, Hg >260 mg/Kg.

● Physical State: Various

● Permissible Waste Codes: D004-11, UW in some states.

RE09 Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >260 mg/Kg.

● Physical State: Various

● Permissible Waste Codes: Universal Waste, D004-11.

RE10 Antifreeze, Used and Unused for Recycling or Fuels Blending. RE10ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, UW in some states.

RE11 Used Oil, <10% Water, <1,000 ppm Total Organic Halides. RE11ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, UW in some states.

RE12 Used Oil, >10% Water, <1,000 ppm Total Organic Halides. RE12ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, UW in some states.

RE13 Used Oil Filters, Drained and Undrained, and/Fully Drained Fuel Filters

● Physical State: Various

● Permissible Waste Codes: D004-11, UW in some states.

RE14 Lead Articles and Spent Ammunitions Meeting Specs for Recovery.

● Physical State: Solid

● Permissible Waste Codes: D004-11, UW in some states.

RE15 Non-PCB Ballasts, Capacitors, Equipment for Recycling. Drained and Undrained. Non-TSCA, Non-RCRA.

● Physical State: Various.

● Permissible Waste Codes: N/A.

RX01 Aerosols, Foaming, Isocyanates or other reactives.

● Permissible Waste Codes: D001, D003, D004-43, Listed.

RX02 Cyanide, >50% Debris, >590 mg/Kg Total CN.

● Permissible Waste Codes: D002-11, Listed.

RX03 Cyanide Liquids, Solids, <50% Debris, 590-10,000 mg/Kg (1%) Total CN.

● Physical State: Various

● Permissible Waste Codes: D002-11, Listed.

RX04 Cyanide Liquids, Solids, <50% Debris, 1%-10% Total CN.

● Physical State: Various

● Permissible Waste Codes: D002-11, Listed.

RX05 Cyanide Liquids, Solids, <50% Debris, >10% Total CN.

● Physical State: Various

● Permissible Waste Codes: D002-11, Listed.

RX06 Oxidizers, i.e. Nitrates, Nitrites, Persulfates, Inorganic Peroxides, No Organic Peroxides.

● Physical State: Various

● Permissible Waste Codes: D001, D003, D004-11, Listed.

RX07 Polymerizing Materials, i.e. Styrene, Isocyanates, Acrylates.

● Physical State: Various

● Permissible Waste Codes: D001, D003, D004-11, Listed.

RX08 Reactive Metals, i.e. Powders, Dusts, Fines. Air/Water Reactive. Shipped Under Oil and/or Special Packaging.

● Physical State: Solid

● Permissible Waste Codes: D001, D003, D004-11, Listed.

RX09 Reactive Metals, Debris. Air/Water Reactive. Shipped Under Oil and/or Special Packaging.

● Physical State: Solid

● Permissible Waste Codes: D001, D003, D004-11, Listed.

RX10 Reactives, Non-Metals, i.e. P-Coded, Temperature Sensitive, PIHs, Air/Water Reactive.

● Physical State: Various

● Permissible Waste Codes: D001, D003, D004-11, Listed.

RX95 Reactive, Ignitable, and Toxic Solids, e.g., tank bottoms, sludge, and/or debris for Thermal Destruction. Contaminated with Mineral Spirits, Motor Oil, Alcohol, Solvents, and Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals. ● Physical State: Solid

● Permissible Waste Codes: D001, D003, D004-11, Listed.

RX96 Reactive Electron Tubes for Demil and Disposal, Water Reactive, Intact, Contains Non-Radioactive Cesium, Certificate of Disposal/Destruction Required.

● Physical State: Solid

● Permissible Waste Codes: D003-11.

RX97 Reactive, Ignitable, and Toxic Liquid for Thermal Destruction. Contains Water, Mineral Spirits, Motor Oil, <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.

● Physical State: Liquid

● Permissible Waste Codes: D001, D003, D004-11, Listed.

RX98 OBA Canisters, Reactive, Spent and/or Unspent. Special packaging may be required.

● Physical State: Solid

● Permissible Waste Codes: D001, D003, D004-11.

RX99 Military Articles for Demil, Reactive, i.e. CDE Kits, Filters, loosepacks, etc. via RCRA Incineration. Does not include OBA/SCBA Canisters. Certificate of Disposal/Destruction Required.

● Physical State: Various

● Permissible Waste Codes: D001-D043, Listed.

TX01 Chromium, Hexavalent, <1% Cr+6, Characteristic Liquids, Solids, Sludges.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D004-11.

TX02 Chromium, Hexavalent, 1-10% Cr+6, Characteristic Liquids, Solids, Sludges.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D004-11.

TX03 Chromium, Hexavalent, >10% Cr+6, Characteristic Liquids, Solids, Sludges.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D004-11.

TX04 Chromium, Hexavalent, <1% Cr+6, Listed Liquids, Solids, Sludges.

● Physical State: Various

● Permissible Waste Codes: D004-11, F006-12, F019.

TX05 Chromium, Hexavalent, Wastewater, Pumpable, <1% Total Metals.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, Listed Inorganics.

TX06 Debris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. No free liquids unless incidental rainwater/condensation (See TX20).

● Physical State: Debris

● Permissible Waste Codes: D004-11, Listed Inorganics.

TX07 Debris, Organic and/or Inorganic Constituents. >50% Debris by volume, >60 mm (~2.5") Particle size. VOSs< 500 ppm. No free liquids unless incidental rainwater/condensation (See TX20).

● Physical State: Debris

● Permissible Waste Codes: D004-43, Listed, but no F020-32.

TX08 Dioxins, Furans, and Precursors. Liquids, Solids, Sludges, Debris.

● Physical State: Various

● Permissible Waste Codes: D004-43, Listed.

TX09 High Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides, Characteristic/Listed.

● Physical State: Various

● Permissible Waste Codes: D004-43, Listed.

TX10 Metals in Wastewater, <5% Suspended Solids, <1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, Listed Inorganics.

TX11 Metals in Wastewater, <5% Suspended Solids, >1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, Listed Inorganics.

TX12 Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Characteristic.

● Physical State: Liquid

● Permissible Waste Codes: D004-11.

TX13 Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Listed.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, Listed.

TX14 Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Characteristic.

● Physical State: Liquid

● Permissible Waste Codes: D004-11.

TX15 Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Listed.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, Listed.

TX16 Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic.

● Physical State: Various

● Permissible Waste Codes: D004-11.

TX17 Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Listed.

● Physical State: Various

● Permissible Waste Codes: D004-11, Listed.

TX18 Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic.

● Physical State: Various

● Permissible Waste Codes: D004-11.

TX19 Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Listed.

● Physical State: Various

● Permissible Waste Codes: D004-11, Listed.

TX20 Metals-Bearing Debris/Solids/Sludges with Free Liquids, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed.

● Physical State: Various

● Permissible Waste Codes: D004-11, Listed.

TX21 Organics in Water, Pumpable, <10% Suspended Solids, <10% Organics, i.e. Toluene, Phenol in water. Not more toxic than common solvents.

● Physical State: Liquid

● Permissible Waste Codes: D004-43, Listed.

TX22 Organics in Solids/Sludges/Debris, i.e. Soil, Tank & Still Bottoms, Adhesives, Filtercake. Not more toxic than common solvents.

● Physical State: Various

● Permissible Waste Codes: D004-43, Listed.

TX23 Toxic/Hazardous Solids and Debris Meeting Universal Treatment Standards (UTS). Subtitle C Landfill Ready. No Free Liquids or PCBs.

● Physical State: Solid

● Permissible Waste Codes: Listed.

TX24 Organic Solvents, Technical Grade Pure or Mixed Solutions, With or Without Water and/or Metals, Pumpable, Flashpoint ≥140°F. ● Physical State: Solid

● Permissible Waste Codes: Listed.

TX25 Blast Media Debris containing DOE-Exempt NORM with radioactivity <2,000 pCi/g. ● Physical State: Solid

● Permissible Waste Codes: Listed.

TX97 Toxic Electron Tubes for Demil and Disposal, Intact, Certificate of Disposal/Destruction Required.

● Physical State: Solid

● Permissible Waste Codes: D004-11.

TX98 Military Items, Demil-required, RCRA Toxic, i.e. CDE Kits, Tents, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.

● Physical State: Various

● Permissible Waste Codes: D004-43, Listed.

TX99 Military Submarine Tiles for Demil via RCRA Incinerator. Use this CLIN even when no toxic Waste Codes apply. Certificate of Destruction Required.

● Physical State: Solid

● Permissible Waste Codes: D004-11.

Sheet1

File details come from the government source that posted it. Updated .