ATT 10- Facility-CLIN Assignment Sheet.xlsx
XLSX spreadsheet 21 KB Posted
- Attached to
- Hazardous Waste Removal and Disposal at Camp Pendleton, CA Federal contract opportunity
- Solicitation number
- SP450020R0019
- Issued by
- Defense Logistics Agency
View the file
Other files for this federal contract opportunity
Show all 31
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Facility CLIN Assignment Sheet
| Master Facility - CLIN Assignment Sheet | ||
| Base | ||
| CLIN | Waste Description | Please use these columns to identify the EPA ID # (or Name/City/State for Non-RCRA) of all facility(s) that will (or may) receive wastes associated with these Base CLINs. Includes all interim and downstream facilities. |
| BA01 | Alkaline Batteries, Managed as Universal Waste (UW) for Recycling or Direct Landfill Disposal. |
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002.
BA02 Calcium Chromate (CaCrO4) Thermal Batteries, Deactivated, Managed as UW/HW for Recycling or Destruction & Disposal.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D001 (Oxidizer), D003-11.
BA03 Carbon-Zinc (CZn) Batteries, Managed as UW/HW for Recycling or Disposal.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002, D004-11.
BA04 Lead Acid Batteries, Managed as UW/HW for Recycling/Recovery Only.
● Physical State: Solid
● Permissible Waste Codes: D002, D004-11.
BA05 Lithium Ion (Li-Ion) Batteries, Managed as UW for Recycling/Recovery Only.
● Physical State: Solid
● Permissible Waste Codes: Universal waste, D002-11.
BA06 Lithium Iron Sulfide (Li2FeS2) Thermal Batteries, Deactivated, Managed as UW/HW for Recycling or Destruction & Disposal.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002-11.
BA07 Lithium Manganese (LiMn and Oxides thereof) Batteries, Managed as UW/HW for Recycling or Destruction & Disposal.
● Physical State: Solid
● Permissible Waste Codes: D002-11.
BA08 Lithium Sulfur Dioxide (LiSO2) Batteries, Managed as UW/HW for Recycling or Destruction & Disposal.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002-11.
BA09 Lithium Thionyl Chloride (LiSCl) Batteries, Managed as UW/HW for Recycling or Destruction & Disposal.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002-11.
BA10 Lithium Batteries, Mixed Types, Deactivated if Applicable, Managed as UW/HW for Recycling or Destruction & Disposal.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002-11.
BA11 Magnesium (Mg) Batteries, Managed as UW/HW for Recycling or Destruction and Disposal.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002, D004-11.
BA12 Mercury (Hg) Batteries, Managed as UW for Recycling/Recovery Only.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002, D004-11.
BA13 Nickel Metal Hydride (NiMh) Batteries, Managed as UW for Recycling/Recovery Only.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002, D004-11.
BA14 Nickel-Cadmium (NiCd) Batteries, Managed as UW for Recycling/Recovery Only.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002, D004-11.
BA15 Silver-Zinc (AgZn) and Zinc Silver Oxidizeride (ZnAgO) Batteries, Managed as UW for Recycling/Recovery Only.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D002, D004-11.
CS01 Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm.
● Physical State: Liquid
● Permissible Waste Codes: D002, D004-11, Listed Inorganics.
CS02 Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, >1% Total Metals, Cr+6 <100 ppm.
● Physical State: Liquid
● Permissible Waste Codes: D002, D004-11, Listed Inorganics.
CS03 Corrosive Acids, Inorganic other than HF and HNO3, Concentrated, <1% Total Metals, Cr+6 <100 ppm.
● Physical State: Liquid
● Permissible Waste Codes: D002, D004-11, Listed Inorganics.
CS04 Corrosive Acids, Chromic (H2Cr04 ), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.
● Physical State: Various
● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11.
CS05 Corrosive Acids, Chromic (H2Cr04 ), 1-10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.
● Physical State: Various
● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11.
CS06 Corrosive Acids, Chromic (H2Cr04), >10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.
● Physical State: Various
● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11.
CS07 Corrosive Acids, Chromic (H2Cr04 ), >100 ppm Cr+6, F-Listed Liquids, Solids, Sludges, Debris.
● Physical State: Various
● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, U032, F-Listed.
CS08 Corrosive Acids, Hydrofluoric (HF) and Nitric (HNO3), <50% in Water, <1% Total Metals, Cr+6 <100 ppm.
● Physical State: Liquid
● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, Listed Inorganics.
CS09 Corrosive Acids, Hydrofluoric (HF) and Nitric (HNO3), >50% in Water, <1% Total Metals, Cr+6 <100 ppm.
● Physical State: Liquid
● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, Listed Inorganics.
CS10 Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.
● Physical State: Liquid
● Permissible Waste Codes: D002, D004-11, Listed Inorganics.
CS11 Corrosive Alkalines, Inorganic, <50% in Water, >1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.
● Physical State: Liquid
● Permissible Waste Codes: D002, D004-11, Listed Inorganics.
CS12 Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/ Sludges/Solids/Debris, Non-Flammable.
● Physical State: Various
● Permissible Waste Codes: D002, D004-11, Listed.
CS13 Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, Non-Flammable.
● Physical State: Various
● Permissible Waste Codes: D002, D004-11, Listed.
CS14 Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.
● Physical State: Various
● Permissible Waste Codes: D002, D004-11, Listed.
CS15 Corrosive Aerosols, Non-Flammable.
● Physical State: Various
● Permissible Waste Codes: D002, D004-11, Listed.
CS99 Military Items for Demil, Corrosive, Inorganic Acids or Bases with Debris and possible Free Liquids, Non-Flammable, i.e. CDE kits, loosepacks. Certificate of Disposal/Destruction Required.
● Permissible Waste Codes: D002, D004-11, Listed.
CY01 Cylinders, Category 1, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".
● Physical State: Comp. Gas
● Permissible Waste Codes: As Appropriate to Each Gas.
CY02 Cylinders, Category 2, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".
● Physical State: Comp. Gas
● Permissible Waste Codes: As Appropriate to Each Gas.
CY03 Cylinders, Category 3, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".
● Physical State: Comp. Gas
● Permissible Waste Codes: As Appropriate to Each Gas.
CY04 Cylinders, Category 4, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".
● Physical State: Comp. Gas
● Permissible Waste Codes: As Appropriate to Each Gas.
CY05 Cylinders, Category 5, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".
● Physical State: Comp. Gas
● Permissible Waste Codes: As Appropriate to Each Gas.
CY06 Cylinders, Category 6, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".
● Physical State: Comp. Gas
● Permissible Waste Codes: As Appropriate to Each Gas.
CY07 Cylinders, Category 7, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".
● Physical State: Comp. Gas
● Permissible Waste Codes: As Appropriate to Each Gas.
CY08 Cylinders, Category 8, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".
● Physical State: Comp. Gas
● Permissible Waste Codes: As Appropriate to Each Gas.
CY09 Cylinders, Acetylene, Contains Asbestos, for Purge and Landfill. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".
● Physical State: Comp. Gas
● Permissible Waste Codes: D001.
CY10 Cylinders, Acetylene, for Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".
● Physical State: Comp. Gas
● Permissible Waste Codes: D001.
CY11 Cylinders, Propane, 20-Lb "Grill Size", for Disposal/Recycle/Reuse. Typically 13" x 17". "ME" = 1 EA Grill-Size Cylinder.
● Physical State: Comp. Gas
● Permissible Waste Codes: D001.
CY12 Cartridges, Flammable Gas, AVGAS, Gas/Diesel Starting, for Disposal/Recycle. Diameter up to 3", Length up to 10".
● Physical State: Comp. Gas
● Permissible Waste Codes: D001.
CY13 Cartridges, Inert Gas, for Disposal/Recycle/Reuse. Diameter up to 1", Length up to 6". "ME" = 1 EA Cartridge.
● Physical State: Comp. Gas
● Permissible Waste Codes: N/A.
FL01 Flammable Aerosols, Non-Foaming, No Isocyanates.
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL02 Flammable Debris, Contaminated with Common Solvents, Shreddable, No Free Liquids, No large metal, rock, or masonry components.
● Physical State: Solid
● Permissible Waste Codes: D001, D004-43, Listed.
FL03 Flammable Liquids/Solids/Sludges/Debris, i.e. tank sludge, lubricants, paint-related waste, adhesives, rags, filters, PPE.
● Physical State: Various
● Permissible Waste Codes: D001-2, D004-43, Listed.
FL04 Flammable Corrosive Liquids/Solids/Sludges/Debris/Aerosols.
● Physical State: Various
● Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed.
FL05 Flammable Liquids, Pumpable, Rich, >7,000 BTU/Lb, <5% Total Chlorine.
● Physical State: Liquid
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL06 Flammable Liquids, Pumpable, Lean, 2,500-7,000 BTU/Lb, <5% Total Chlorine.
● Physical State: Liquid
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL07 Flammable Liquids, Pumpable, Lean to Rich, >2,500 BTU/Lb, 5-10% Total Chlorine.
● Physical State: Liquid
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL08 Flammable Resuspendable Solids/Sludges, Rich, >7,000 BTU/Lb, <5% Total Chlorine.
● Physical State: Various
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL09 Flammable Resuspendable Solids/Sludges, Lean, 2,500-7,000 BTU/Lb, <5% Total Chlorine.
● Physical State: Various
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL10 Flammable Resuspendable Solids/Sludges, Lean to Rich, >2,500 BTU/Lb, 5-10% Total Chlorine.
● Physical State: Various
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL11 Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.
● Physical State: Liquid
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL12 Flammable Solids/Sludges, Highly Chlorinated (>10%), Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.
● Physical State: Various
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL13 Oxidizers, Non-Reactive, other than chromic acid (see Corrosives), Liquids/Sludges/Solids/Debris.
● Physical State: Various
● Permissible Waste Codes: D001(Oxidizer), D002, D004-43, Listed.
FL14 Paints, Loose-Packed, Latex and/or Oil-Based, and Paint-Related Materials, >2,500 BTU/Lb (See Base CLIN NR06 for 100% Latex).
● Physical State: Various
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL15 Water Contaminated with Solvents, Pumpable, <2,500 BTU/Lb.
● Physical State: Liquid
● Permissible Waste Codes: D001 (IGN), D004-43, Listed.
FL99 Military Items, Demil-Required Flammable Solids/Liquids/Debris, i.e. CDE Kits, Vials, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.
● Physical State: Various
● Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed.
LP01 Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.
● Physical State: Various
● Permissible Waste Codes: D002, D004-11, Listed Corrosives.
LP02 Lab Packs/Loose Packs, Mercury, Elemental Liquid.
● Physical State: Various
● Permissible Waste Codes: D004-11, Listed Inorganics.
LP03 Lap Packs/Loose Packs, Flammables other than Paints.
● Physical State: Various
● Permissible Waste Codes: D001-2, D004-43, Listed Flammables.
LP04 Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, other than paints, including pharmaceuticals.
● Physical State: Various
● Permissible Waste Codes: N/A.
LP05 Lab Packs/Loose Packs, Non-Reactive Oxidizers.
● Physical State: Various
● Permissible Waste Codes: D001 (Oxidizer), D004-11, Listed.
LP06 Lab Packs/Loose Packs, Reactive Oxidizers, Includes Organic Peroxides, Special Packaging Required.
● Physical State: Various
● Permissible Waste Codes: D001 (Oxidizer), D003-11, Listed.
LP07 Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, Includes Broken Sodium Lamps, Special Packaging Required.
● Physical State: Various
● Permissible Waste Codes: D001, D003-11, Listed.
LP08 Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, Special Packaging Required.
● Physical State: Various
● Permissible Waste Codes: D001-43, Listed.
LP09 Lab Packs/Loose Packs, Toxic Metals.
● Physical State: Various
● Permissible Waste Codes: D004-11, Listed Inorganics.
LP10 Lab Packs/Loose Packs, Toxic Organics.
● Physical State: Various
● Permissible Waste Codes: D004-43, Listed.
LP11 Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, including pharmaceuticals.
● Physical State: Various
● Permissible Waste Codes: D004-43, Listed.
LP12 Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals.
● Physical State: Various
● Permissible Waste Codes: D004-43, U-Listed Codes.
LP79 Lab Packs/Loose Packs, Flammables,Human Waste.
● Physical State: Various
● Permissible Waste Codes: D001-2, D004-43, Listed Flammables.
NR01 Non-RCRA Solids, Direct Landfill Ready (Subtitle D or Equivalent). No Free Liquids. Includes Non-PCB Drained/Dry Transformers, Ballasts, Capacitors, and Related Equipment.
● Physical State: Solid
● Permissible Waste Codes: N/A.
NR02 Non-RCRA Solids with Asbestos, Direct Landfill Ready (Subtitle D or Equivalent). Special Packaging Required. No Free Liquids.
● Physical State: Solid
● Permissible Waste Codes: N/A.
NR03 Non-RCRA Liquids, Pumpable, Aqueous (Water-Based).
● Physical State: Liquid
● Permissible Waste Codes: N/A.
NR04 Non-RCRA Liquids, Pumpable, Organic-Based.
● Physical State: Liquid
● Permissible Waste Codes: N/A.
NR05 Non-RCRA Liquids, Sludges, Solids and Debris with Free Liquids requiring solidification prior to landfill (subtitle D or equivalent). Includes Non-PCB Oil-Filled Transformers, Ballasts, Capacitors and Related Equipment.
● Physical State: Various
● Permissible Waste Codes: N/A.
NR06 Non-RCRA Loose-Packed Paints, 100% Water-Based (Latex).
● Physical State: Various
● Permissible Waste Codes: N/A.
NR07 Non-RCRA Pharmaceuticals for Thermal Destruction, Prescription and Non-Prescription. No DEA Restricted Meds. Certificate of Destruction Required.
● Physical State: Various
● Permissible Waste Codes: N/A.
NR08 Non-RCRA (RCRA-Empty) Containers, Metal & Plastic/Poly, Crushed, Recycle or Disposal.
● Physical State: Solid
● Permissible Waste Codes: N/A.
NR09 Non-RCRA (RCRA-Empty) Containers, Metal, Intact, Recycle or Disposal.
● Physical State: Solid
● Permissible Waste Codes: N/A.
NR10 Non-RCRA (RCRA-Empty) Containers, Plastic/Poly, Intact, Recycle or Disposal.
● Physical State: Solid
● Permissible Waste Codes: N/A.
NR11 Non-RCRA Combustible Solids for Waste-To-Energy (WTE) Disposal. May contain some free liquids.
● Physical State: Various
● Permissible Waste Codes: N/A.
NR12 Non-RCRA Solids containing DOE-Exempt NORM with radioactivity <2,000 pCi/g. ● Physical State: Solid
● Permissible Waste Codes: N/A.
NR91 Non-RCRA AFFF-Contaminated Solids/Sludges/Debris for RCRA Incineration, e.g., Soil, PPE, Filter Media. May contain some free liquids. Certificate of Disposal/ Destruction Required ● Physical State: Various
● Permissible Waste Codes: N/A.
NR92 Non-RCRA Liquids for RCRA Incineration, Pumpable, Unused AFFF. Certificate of Disposal/Destruction Required.
***Specifically for Navy added to Air Force AFFF contracts*** ● Physical State: Liquid
● Permissible Waste Codes: N/A.
NR93 Non-RCRA AFFF Concentrate Liquid for RCRA Incineration, Unused or >10% AFFF Product, Pumpable. Certificate of Disposal/Destruction Required. ● Physical State: Liquid
● Permissible Waste Codes: N/A.
NR94 Non-RCRA AFFF Rinsate/Water-Diluted Liquid for RCRA Incineration, Used or >90% Water, Pumpable. Certificate of Disposal/Destruction Required. ● Physical State: Liquid
● Permissible Waste Codes: N/A.
NR96 Non-RCRA Liquids, Pumpable, for RCRA Incineration. Certificate of Disposal/Destruction Required.
● Physical State: Liquid
● Permissible Waste Codes: N/A.
NR97 Non-RCRA Solids/Sludges/Debris, for RCRA Incineration. Certificate of Disposal/Destruction Required.
● Physical State: Various
● Permissible Waste Codes: N/A.
PC01 PCB and PCB/RCRA-Mixed Waste Contaminated with or Containing >5ppm Source, i.e. Debris, Sludge, Water, Leaking Capacitors, Fluids other than Transformer Mineral Oil. Certificate of Destruction Required. (2.1)
● Physical State: Various
● Permissible Waste Codes: Characteristic, Listed.
PC02 PCB Mineral Oil from Transformers, <5 ppm PCBs, Non-RCRA. (2.1)
● Physical State: Liquid
● Permissible Waste Codes: N/A.
PC03 PCB Mineral Oil from Transformers, 5-4,000 ppm PCBs. Non-RCRA, Certificate of Recycling or Destruction Required. (2.1)
● Physical State: Liquid
● Permissible Waste Codes: N/A.
PC04 PCB Mineral Oil , Water, Other Fluids, >4,000 ppm PCBs. Certificate of Destruction Required. (2.1)
● Physical State: Liquid
● Permissible Waste Codes: Characteristic, Listed.
PC05 PCB Oil-Filled Capacitors/Equipment other than Transformers, 1-49 ppm PCBs, Non-RCRA. (2.1)
● Physical State: Various
● Permissible Waste Codes: N/A.
PC06 PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, >5 ppm PCBs, Non-RCRA, Certificate of Recycling or Destruction Required. (2.1)
● Physical State: Various
● Permissible Waste Codes: N/A.
PC07 PCB Oil-Filled Transformers, <5 ppm PCBs, Non-RCRA. (2.1)
● Physical State: Various
● Permissible Waste Codes: N/A.
PC08 PCB Oil-Filled Transformers, >5 ppm PCBs. Certificate of Recycling or Destruction Required. (2.1)
● Physical State: Various
● Permissible Waste Codes: N/A.
PC09 PCB Solids/Debris Contaminated with <5 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-RCRA. (2.1)
● Physical State: Solid
● Permissible Waste Codes: N/A.
PC10 PCB Solids/Debris Contaminated with >5 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-RCRA. Certificate of Disposal, Recycling or Destruction Required. (2.1)
● Physical State: Solid
● Permissible Waste Codes: N/A.
PC11 PCB and Non-PCB Related ballast and other devices containing <5 ppm for Mandatory Recycling of recycable components. Certificate of Recycling Required. (See 2.1). ● Physical State: Solid
● Permissible Waste Codes: N/A.
PC12 PCB Related ballast and other devices containing ≥ 5 ppm for Mandatory Recycling of recycable components. Certificate of Recycling Required. (See 2.1). ● Physical State: Solid
● Permissible Waste Codes: N/A.
RE01 Lamps, Fluorescent, Intact, CFLs and <4 ft = Each (ME), U-Bent, Circulars and 4-6 ft Linears = Small (M1), 6-8 ft = Medium (M2), >8 ft = Large (M3).
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D004-11.
RE02 Lamps, Fluorescent, Crushed/Broken, with Filters.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D004-11.
RE03 Lamps, Halogen.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste, D004-11.
RE04 Lamps, High Intensity Discharge (HID).
● Physical State: Solid
● Permissible Waste Codes: Universal Waste D004-11.
RE05 Lamps, Mercury/Mercury Vapor.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste D004-11.
RE06 Lamps, Metal Halide and Metal Hydride, including Sodium.
● Physical State: Solid
● Permissible Waste Codes: Universal Waste D003-11.
RE07 Mercury, High, COD Vials, Nessler's Reagent, Chemicals and Residues, Hg >260 mg/Kg.
● Physical State: Various
● Permissible Waste Codes: D002, D004-11, UW some states.
RE08 Mercury, High, Dental Amalgams & Residues, Hg >260 mg/Kg.
● Physical State: Various
● Permissible Waste Codes: D004-11, UW in some states.
RE09 Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >260 mg/Kg.
● Physical State: Various
● Permissible Waste Codes: Universal Waste, D004-11.
RE10 Antifreeze, Used and Unused for Recycling or Fuels Blending. RE10ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.
● Physical State: Liquid
● Permissible Waste Codes: D004-11, UW in some states.
RE11 Used Oil, <10% Water, <1,000 ppm Total Organic Halides. RE11ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.
● Physical State: Liquid
● Permissible Waste Codes: D004-11, UW in some states.
RE12 Used Oil, >10% Water, <1,000 ppm Total Organic Halides. RE12ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.
● Physical State: Liquid
● Permissible Waste Codes: D004-11, UW in some states.
RE13 Used Oil Filters, Drained and Undrained, and/Fully Drained Fuel Filters
● Physical State: Various
● Permissible Waste Codes: D004-11, UW in some states.
RE14 Lead Articles and Spent Ammunitions Meeting Specs for Recovery.
● Physical State: Solid
● Permissible Waste Codes: D004-11, UW in some states.
RE15 Non-PCB Ballasts, Capacitors, Equipment for Recycling. Drained and Undrained. Non-TSCA, Non-RCRA.
● Physical State: Various.
● Permissible Waste Codes: N/A.
RX01 Aerosols, Foaming, Isocyanates or other reactives.
● Permissible Waste Codes: D001, D003, D004-43, Listed.
RX02 Cyanide, >50% Debris, >590 mg/Kg Total CN.
● Permissible Waste Codes: D002-11, Listed.
RX03 Cyanide Liquids, Solids, <50% Debris, 590-10,000 mg/Kg (1%) Total CN.
● Physical State: Various
● Permissible Waste Codes: D002-11, Listed.
RX04 Cyanide Liquids, Solids, <50% Debris, 1%-10% Total CN.
● Physical State: Various
● Permissible Waste Codes: D002-11, Listed.
RX05 Cyanide Liquids, Solids, <50% Debris, >10% Total CN.
● Physical State: Various
● Permissible Waste Codes: D002-11, Listed.
RX06 Oxidizers, i.e. Nitrates, Nitrites, Persulfates, Inorganic Peroxides, No Organic Peroxides.
● Physical State: Various
● Permissible Waste Codes: D001, D003, D004-11, Listed.
RX07 Polymerizing Materials, i.e. Styrene, Isocyanates, Acrylates.
● Physical State: Various
● Permissible Waste Codes: D001, D003, D004-11, Listed.
RX08 Reactive Metals, i.e. Powders, Dusts, Fines. Air/Water Reactive. Shipped Under Oil and/or Special Packaging.
● Physical State: Solid
● Permissible Waste Codes: D001, D003, D004-11, Listed.
RX09 Reactive Metals, Debris. Air/Water Reactive. Shipped Under Oil and/or Special Packaging.
● Physical State: Solid
● Permissible Waste Codes: D001, D003, D004-11, Listed.
RX10 Reactives, Non-Metals, i.e. P-Coded, Temperature Sensitive, PIHs, Air/Water Reactive.
● Physical State: Various
● Permissible Waste Codes: D001, D003, D004-11, Listed.
RX95 Reactive, Ignitable, and Toxic Solids, e.g., tank bottoms, sludge, and/or debris for Thermal Destruction. Contaminated with Mineral Spirits, Motor Oil, Alcohol, Solvents, and Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals. ● Physical State: Solid
● Permissible Waste Codes: D001, D003, D004-11, Listed.
RX96 Reactive Electron Tubes for Demil and Disposal, Water Reactive, Intact, Contains Non-Radioactive Cesium, Certificate of Disposal/Destruction Required.
● Physical State: Solid
● Permissible Waste Codes: D003-11.
RX97 Reactive, Ignitable, and Toxic Liquid for Thermal Destruction. Contains Water, Mineral Spirits, Motor Oil, <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.
● Physical State: Liquid
● Permissible Waste Codes: D001, D003, D004-11, Listed.
RX98 OBA Canisters, Reactive, Spent and/or Unspent. Special packaging may be required.
● Physical State: Solid
● Permissible Waste Codes: D001, D003, D004-11.
RX99 Military Articles for Demil, Reactive, i.e. CDE Kits, Filters, loosepacks, etc. via RCRA Incineration. Does not include OBA/SCBA Canisters. Certificate of Disposal/Destruction Required.
● Physical State: Various
● Permissible Waste Codes: D001-D043, Listed.
TX01 Chromium, Hexavalent, <1% Cr+6, Characteristic Liquids, Solids, Sludges.
● Physical State: Various
● Permissible Waste Codes: D001 (Oxidizer), D004-11.
TX02 Chromium, Hexavalent, 1-10% Cr+6, Characteristic Liquids, Solids, Sludges.
● Physical State: Various
● Permissible Waste Codes: D001 (Oxidizer), D004-11.
TX03 Chromium, Hexavalent, >10% Cr+6, Characteristic Liquids, Solids, Sludges.
● Physical State: Various
● Permissible Waste Codes: D001 (Oxidizer), D004-11.
TX04 Chromium, Hexavalent, <1% Cr+6, Listed Liquids, Solids, Sludges.
● Physical State: Various
● Permissible Waste Codes: D004-11, F006-12, F019.
TX05 Chromium, Hexavalent, Wastewater, Pumpable, <1% Total Metals.
● Physical State: Liquid
● Permissible Waste Codes: D004-11, Listed Inorganics.
TX06 Debris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. No free liquids unless incidental rainwater/condensation (See TX20).
● Physical State: Debris
● Permissible Waste Codes: D004-11, Listed Inorganics.
TX07 Debris, Organic and/or Inorganic Constituents. >50% Debris by volume, >60 mm (~2.5") Particle size. VOSs< 500 ppm. No free liquids unless incidental rainwater/condensation (See TX20).
● Physical State: Debris
● Permissible Waste Codes: D004-43, Listed, but no F020-32.
TX08 Dioxins, Furans, and Precursors. Liquids, Solids, Sludges, Debris.
● Physical State: Various
● Permissible Waste Codes: D004-43, Listed.
TX09 High Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides, Characteristic/Listed.
● Physical State: Various
● Permissible Waste Codes: D004-43, Listed.
TX10 Metals in Wastewater, <5% Suspended Solids, <1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed.
● Physical State: Liquid
● Permissible Waste Codes: D004-11, Listed Inorganics.
TX11 Metals in Wastewater, <5% Suspended Solids, >1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed.
● Physical State: Liquid
● Permissible Waste Codes: D004-11, Listed Inorganics.
TX12 Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Characteristic.
● Physical State: Liquid
● Permissible Waste Codes: D004-11.
TX13 Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Listed.
● Physical State: Liquid
● Permissible Waste Codes: D004-11, Listed.
TX14 Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Characteristic.
● Physical State: Liquid
● Permissible Waste Codes: D004-11.
TX15 Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Listed.
● Physical State: Liquid
● Permissible Waste Codes: D004-11, Listed.
TX16 Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic.
● Physical State: Various
● Permissible Waste Codes: D004-11.
TX17 Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Listed.
● Physical State: Various
● Permissible Waste Codes: D004-11, Listed.
TX18 Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic.
● Physical State: Various
● Permissible Waste Codes: D004-11.
TX19 Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Listed.
● Physical State: Various
● Permissible Waste Codes: D004-11, Listed.
TX20 Metals-Bearing Debris/Solids/Sludges with Free Liquids, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed.
● Physical State: Various
● Permissible Waste Codes: D004-11, Listed.
TX21 Organics in Water, Pumpable, <10% Suspended Solids, <10% Organics, i.e. Toluene, Phenol in water. Not more toxic than common solvents.
● Physical State: Liquid
● Permissible Waste Codes: D004-43, Listed.
TX22 Organics in Solids/Sludges/Debris, i.e. Soil, Tank & Still Bottoms, Adhesives, Filtercake. Not more toxic than common solvents.
● Physical State: Various
● Permissible Waste Codes: D004-43, Listed.
TX23 Toxic/Hazardous Solids and Debris Meeting Universal Treatment Standards (UTS). Subtitle C Landfill Ready. No Free Liquids or PCBs.
● Physical State: Solid
● Permissible Waste Codes: Listed.
TX24 Organic Solvents, Technical Grade Pure or Mixed Solutions, With or Without Water and/or Metals, Pumpable, Flashpoint ≥140°F. ● Physical State: Solid
● Permissible Waste Codes: Listed.
TX25 Blast Media Debris containing DOE-Exempt NORM with radioactivity <2,000 pCi/g. ● Physical State: Solid
● Permissible Waste Codes: Listed.
TX97 Toxic Electron Tubes for Demil and Disposal, Intact, Certificate of Disposal/Destruction Required.
● Physical State: Solid
● Permissible Waste Codes: D004-11.
TX98 Military Items, Demil-required, RCRA Toxic, i.e. CDE Kits, Tents, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.
● Physical State: Various
● Permissible Waste Codes: D004-43, Listed.
TX99 Military Submarine Tiles for Demil via RCRA Incinerator. Use this CLIN even when no toxic Waste Codes apply. Certificate of Destruction Required.
● Physical State: Solid
● Permissible Waste Codes: D004-11.
Sheet1
File details come from the government source that posted it. Updated .