Atch 3_Bldg 520 A 2.0 with Blue Beam Markups.pdf
PDF 268 KB Posted
- Attached to
- Epoxy Floor Coating Repair, Ames Federal contract opportunity
- Solicitation number
- 12639525Q0164
About this file
This document is a floor plan and specification sheet for a floor coating repair project at the USDA-NCAH Building 520 in Ames, Iowa. The project involves removing existing epoxy coating in Rooms 105, 106, 107, and 108, and installing a new 3/4" plywood sub-floor with a 6-inch integral base and floor coating. The total floor area for new coating is approximately 1,016 square feet, with 202 linear feet of integral base to be installed.
Key specifications include maintaining existing door configurations, providing transition strips at door openings and floor drains, and ensuring the new floor coating resists cracking and provides good traction when wet. The project is classified under NAICS code 238330 for Flooring Contractors, with a small business size standard of $19 million. The estimated project magnitude is between $25,000 and $100,000, targeting a modular animal research building constructed in 2008 with a deteriorating floor coating system.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 12639525Q0164-0001.pdf | ||
| Site visit sign-in sheet.pdf | ||
| Atch 1_SOW Building 520 Floor Coating Repair.doc | DOC document | |
| Atch 7_StoncladGS PDS.pdf | ||
| 12639525Q0164.pdf | ||
| Atch 5_Specification Section 096723 Resinous Flooring.docx | DOCX document | |
| Atch 9_ Floor Photos.pdf | ||
| Atch 8_ Stonkote HT4 Product Data.pdf | ||
| Atch 6_Stonchem 441 Product Data.pdf | ||
| Atch 4_G001 Title Page Building 520 Floor Coating Repair.pdf | ||
| Atch 2_Federal Construction Wage Rates_Story Cty.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 3, 12639525Q0164
Michael.Kuennen Rectangle
Michael.Kuennen Rectangle
Michael.Kuennen Arrow
Michael.Kuennen Arrow
Michael.Kuennen Text Box
USDA-NCAH BUILDING 520 FLOOR COATING REPAIR
Text Box Rooms 105 and 106 have existing epoxy still in place on floor and 4 inch integral cove base that needs to be removed to prepare for the new 3/4" plywood sub-floor, 6 inch integral base and floor coating. Existing doors shall not be modified, but door sweeps may be removed and reinstalled by Contractor as required for ease of installation. Contractor shall provide transition strips as needed at door openings and around floor drains as required.
Michael.Kuennen Text Box Rooms 107 and 108 have most of the existing epoxy coating removed on the floor with a peeling epoxy paint coating. The existing 4 inch epoxy integral base will need to be removed to prepare for the new 3/4" plywood sub-floor, 6 inch integral base and floor coating. Existing doors shall not be modified, but door sweeps may be removed and reinstalled by Contractor as required for ease of installation. Contractor shall provide transition strips at door openings and around floor drains as required.
Michael.Kuennen Text Box Total floor area for new coating is approximately 1,016 SF
Total linear feet of integral base is approximately 202 FT
Michael.Kuennen Arrow
Michael.Kuennen Text Box
NORTH
Michael.Kuennen Text Box
DRAWING A2.0
Michael.Kuennen Text Box Note: The floor drains are not shown as constructed, Room 106 and 108 each have four floor drains, one in each corner on the south side of the rooms and two in-between approximately equally space.