Attachment_10_-_BuildingDescs_PineKnot-FireAlarm.pdf
PDF 97 KB Posted
- Attached to
- Multiple Construction Projects - Pine Knot Job Corps Center Federal contract opportunity
- Solicitation number
- AG-82A7-S-17-0051
About this file
Attachment 10
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF-30_Amend_000002_-_AG-82A7-S-17-0051.pdf | ||
| A13_Q&A_5.22.2017.pdf | ||
| A13_Q&A_4.28.2017.docx | DOCX document | |
| SF-30_Amendment_000001_-_AG-82A7-S-17-0051.pdf | ||
| Attachment_9_-_Proposal_Submission_Package.pdf | ||
| Attachment_3_-_Project_Specifications_-_Misc._Building_Exterior_Repairs.pdf | ||
| Attachment_2_-_Drawings_-_Culinary_Arts_Buildout.pdf | ||
| Attachment_5_-_Project_Specifications_and_Drawing_-_Fire_Detection_System.pdf | ||
| Attachment_1_-_Project_Specifications_-_Culinary_Arts_Buildout.pdf | ||
| Attachment_8_-_DB_-_Pine_Knot_-_Building.pdf | ||
| Attachment_6_-_Walkin_Refrigerator_and_Freezer_Specifications.pdf | ||
| Solicitation_-_AG-82A7-S-17-0051.pdf | ||
| Attachment_4_-_Drawing_-_Misc._Building_Exterior_Repairs.pdf | ||
| Attachment_7_-_DB_-_Pine_Knot_-_Residential.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building Descriptions Date: 05/18/2016Center : Pine Knot (00320) Page: 12 of 114
Building: 0009 - CENTER MAINTENANCE
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
Drywall Wood Paneling
Wood Unit - Wood Frame
Mechanical Restroom
Ventilation Area Served
VERTICAL CIRCULATION
None
Double Hung - Vinyl Frame; Double Glazing;
Acoustical Tile Gypsum Board Plywood
Exhaust Ventilation
Windows6.
Floors1. Asbestos: Yes
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Two Goodman gas fired packaged units heat and cool the entire building. One unit is model GPG 12240701a, with a gas heat input of 69,000 BTUH. The other is Goodman PGB 0361001B, with a rated gas heat input of 92,000 BTUH.
Comments:
HVAC
Heat1.
Gas-Fired Furnace
Single Duct None Electric Mechanical None Entire Building
Ventilation2.
Ceilings
Page: 13 of 114
Building: 0009 - CENTER MAINTENANCE
There is a 30 gallon electric water heater, Richmond model 6K30-2.Comments:
Cast-Iron None None
Electric Water Cooler Lavatory Sink Urinal Water Closet (Tank)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank located at the northwest side of the building via underground cable and terminated in the 200A main branch panelboard with 200A main circuit breaker (MCB).
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Packaged Direct
Expansion (Air Source)
Single Duct None Electric Mechanical None Entire Building
Incandescent Comments: The exterior building-mounted light fixtures are controlled by a photocell.
Main Branch Panel 120/208V, 1-Phase, 3 Wire Branch Panel Only Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Cooling is provided by the same units that provide heating. The model numbers are given under heating.
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES
Exterior Lighting1.
3. Air Conditioning
LIGHTING
Page: 14 of 114
Building: 0009 - CENTER MAINTENANCE
FIRE ALARM
Comments: The fire alarm control panel is by Cerberus-Pyrotronics. This panel is located in the maintenance office.
Comments: The building is connected to the LAN. The public address system is not connected and therefore is not operational.
Audible Alarm Control Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None None
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Conference Rooms
Toilets
Storage Rooms
Area Recommended Recorded Light Type
Battery Backup Battery Backup
Emergency Exit
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 2
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoNo
BUILDING UTILITY METERING
Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good
Type Location N/A N/A
CARBON MONOXIDE DETECTION
Detection Required No
Number of Deficiencies = 0
IMPAIRMENT
Potentially Impaired
DOL Responded
DOL Determination
Potential Impaired Comments DOL Determination Discussion/Comments
Page: 31 of 114
Building: 0014 - GYMNASIUM/RECREATION HALL
INTERIOR FINISH
Carpet Ceramic Tile Concrete Rubberized Athletic Flooring Vinyl Tile
Drywall Wood Paneling
Metal Unit - Metal Frame Wood Unit - Wood Frame
VERTICAL CIRCULATION
Metal Stairs Wood Stairs (2 Interior) Comments: The building has two interior wood stairs and one exterior metal fire escape stair.
Sliding - Aluminum Frame; Double Glazing;
Acoustical Tile Exposed Structure Gypsum Board
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4. Number of Deficiencies = 2
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The gym is served by two Trane packaged units located in the rear of the gym. One unit is Trane model YCH180B3LOHB and the other unit is Trane model YCH240BBLOJB.
First floor recreation areas are served by two Trane gas fired furnaces. One is model number TXC049C4HPD0 and one is model number TXC037C4HPC0.
Second floor recreation areas are served by two electric furnaces. One unit is a Trane model TWE120A300 and the other unit is a Maytag model B5BMX60K-C.
Comments:
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Packaged
Gas-Fired Furnace
Electric Resistance
Single Duct
Single Duct
Single Duct
None
None
None
Electric
Electric
Electric
Mechanical
Mechanical
Mechanical
None
None
None
Gymnasium
Recreation Area
Recreation Area
Page: 32 of 114
Building: 0014 - GYMNASIUM/RECREATION HALL
Mechanical
Mechanical
Restroom
Kiln Area
Comments: The kilns are served by a dedicated exhaust hood.
Domestic hot water is provided by a Richmond model 6E30-2 electric water heater.Comments:
Cast Iron None None
Electric Water Cooler Lavatory Shower Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Ventilation Area Served
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Split Direct Expansion (Air
Source)
Packaged Direct
Expansion (Air Source)
Single Duct
Single Duct
Refrigerant
None
Electric
Electric
Mechanical
Mechanical
None
None
Recreation Area
Gymnasium
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Exhaust Ventilation
The four furnaces are paired with outdoor air cooled condensing units. The condensing units are as follows: Trane 2TTA0036A300A, Trane TTA120A300FA, Trane TTA090A300FA and Maytag
MSH4BD060K.
The gym is served by two packaged units located outside. Data on the units is listed under heating.
Comments:
Comments:
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
Page: 33 of 114
Building: 0014 - GYMNASIUM/RECREATION HALL
Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank located at the northeast side of the building via overhead cable to an 800A main distribution panelboard (MDP) with 800A main circuit breaker (MCB) located in the electrical room.
FIRE ALARM
Comments: The fire alarm control panel is a Cerberus-Pyrotronics. This panel is located in the main lobby.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Control Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Comments: Recorded footcandle levels include natural light contribution.
High Intensity Discharge (HID) Comments: Building-mounted light fixtures are controlled by astronomical time clock located in the electrical room.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
High Intensity Discharge (HID)
T8 - Fluorescent
T8 - Fluorescent
Offices
Equipment Rooms (Elec/Mech)
Toilets
Storage Rooms
Vocational
Gymnasium
Locker Room
Recreation
Area Recommended Recorded Light Type
Battery Backup Battery Backup
Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
Number of Deficiencies = 1
ELECTRICAL SERVICES Number of Deficiencies = 6
Exterior Lighting1.
Interior Lighting2. Number of Deficiencies = 1
Emergency /Exit Lighting3. Number of Deficiencies = 3
Type Location N/A N/A
CARBON MONOXIDE DETECTION
LIGHTING
Detection Required No
Number of Deficiencies = 0
Page: 60 of 114
Building: 0057 - KING HALL DORMITORY (MALE)
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall Painted CMU
Metal Unit - Metal Frame Wood Unit - Metal Frame
Mechanical Toilet/Shower
Comments: The attic houses the following air handlers : Trane TWE030P130B0, mfg 10/2002; International Comfort FSM46000A, mfg date Oct 2010; Goodman ARUF486016CA
Ventilation Area Served
VERTICAL CIRCULATION
Exterior Concrete Stairs Ramp
Double Hung - Wood Frame; Double Glazing;
Acoustical Tile Gypsum Board
Exhaust Ventilation
Windows6.
Floors1. Asbestos: Yes
Interior Walls2.
3.
Interior Doors4. Number of Deficiencies = 1
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Three Trane model TWE series split system heat pumps serve the dorm. A Norodyne model B2BM030K-B heat pump serves the lower level. The three outdoor units for the dorm are as follows:
Trane model 2TWA 0030A300AB, Tappan model N4H360GHB400, and International Comfort Products model X131076544. The outdoor unit for the lower level is a Tempstar E110600250, mfg date Feb 2011.
Comments:
HVAC
Heat1.
Split Heat Pump (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
Ventilation2. Number of Deficiencies = 1
Page: 61 of 114
Building: 0057 - KING HALL DORMITORY (MALE)
There are two 120 gallon each electric hot water heaters. One is a Rheem model EGS18-120-G and the other is a Bradford White model MII120-18-3SF-39.
Comments:
Cast Iron None None
Electric Water Cooler Hose Bibb Lavatory Service Sink Shower Urinal Water Closet (Flush Valve)
None
None None ABC Type Fire Extinguisher
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Split Heat Pump (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Cooling for the dorm is provided by three split system heat pumps. Cooling for the lower level is provided by one split system heat pump. Data on the units is provided under "Heating".
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
Number of Deficiencies = 1FIRE PROTECTION
Page: 62 of 114
Building: 0057 - KING HALL DORMITORY (MALE)
Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the northwest side of the building, via a 600A pole-mounted main circuit breaker. From this circuit breaker the electrical service is routed to the building via underground cable and terminated in the 600A main panelboard with 600A main circuit breaker (MCB). The service equipment is located in the electrical/mechanical room.
FIRE ALARM
Comments: The fire alarm control panel is a Siemens FS-250. This panel is located in the RA office.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Comments: Recorded footcandle levels include natural light contribution.
High Intensity Discharge (HID) Comments: Building-mounted lighting is controlled by photocell and an astronomical time clock located in the electrical/mechanical room.
T8 - Fluorescent
T8 - Fluorescent
Compact Fluorescent
T8 - Fluorescent
Compact Fluorescent
T8 - Fluorescent
T12 - Fluorescent
T8 - Fluorescent
Offices
Corridors & Stairs
Equipment Rooms (Elec/Mech)
Toilets
Storage Rooms
Housing Lounge
Shower
Sleeping Rooms
Area Recommended Recorded Light Type
Battery Backup Battery Backup
Main Panelboard 120/240V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
Number of Deficiencies = 2
ELECTRICAL SERVICES Number of Deficiencies = 1
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 2
Type Location None None
There is no plausible means by which harmful levels of CO could enter sleeping rooms.
CARBON MONOXIDE DETECTION
LIGHTING
Detection Required
Page: 65 of 114
Building: 0059 - PERKINS DORMITORY (MALE)
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall Painted CMU
Metal Unit - Metal Frame Wood Unit - Metal Frame
Mechanical Toilet/Shower
Ventilation Area Served
VERTICAL CIRCULATION
Concrete Stairs Ramp
Double Hung - Wood Frame; Double Glazing;
Gypsum Board Plaster
Exhaust Ventilation
Number of Deficiencies = 1
Number of Deficiencies = 1
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4. Number of Deficiencies = 1
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heating is provided by three split system heat pumps. The indoor units are Trane model
TWEO060A100EL.
Comments:
HVAC
Heat1.
Split Heat Pump (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
Page: 66 of 114
Building: 0059 - PERKINS DORMITORY (MALE)
Domestic hot water is provided by two Bradford White model MII120-183SF39 120 gallon electric water heaters.
Comments:
Cast Iron None None
Electric Water Cooler Hose Bibb Lavatory Shower Sink Urinal Water Closet (Flush Valve)
None
None None ABC Type Fire Extinguisher
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Split Heat Pump (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Outdoor units are Trane model 2TWA0060A3000AB, and Goodman CPLJ48-1B plus International Comfort Product model X12147111, mfg date Aprilo 2012.
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
Page: 67 of 114
Building: 0059 - PERKINS DORMITORY (MALE)
Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the west side of the building, via a 600A pole-mounted main circuit breaker. From this circuit breaker the electrical service is routed to the building via underground cable and terminated in the 600A main panelboard with 600A main circuit breaker (MCB). The service equipment is located in the electrical/mechanical room.
FIRE ALARM
Comments: The fire alarm control panel is a Simens FS-250. This panel is located in the RA office.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Comments: Recorded footcandle levels include natural light contribution.
High Intensity Discharge (HID) Comments: The exterior building-mounted light fixtures are controlled by a photocell.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Compact Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Corridors & Stairs
Equipment Rooms (Elec/Mech)
Toilets
Storage Rooms
Housing Lounge
Shower
Sleeping Rooms
Area Recommended Recorded Light Type
Battery Backup Battery Backup
Main Panelboard 120/240V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
Number of Deficiencies = 2
ELECTRICAL SERVICES Number of Deficiencies = 1
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3.
Type Location None None
There is no plausible means by which harmful levels of CO could enter sleeping rooms.
CARBON MONOXIDE DETECTION
LIGHTING
Detection Required
Page: 70 of 114
Building: 0060 - WASHINGTON DORMITORY (MALE)
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall Painted CMU
Wood Unit - Metal Frame
Mechanical Toilet/Shower
Ventilation Area Served
VERTICAL CIRCULATION
Ramp
Double Hung - Wood Frame; Double Glazing;
Gypsum Board Plaster
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4. Number of Deficiencies = 2
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heating is provided by three split system heat pumps. The outdoor units are two Trane model 2TWA0060A3000AB, and one International Comfort Products model N4H330AHB300. Indoor units are two Trane TWE036PBOBO and one International Comfort Products model FSM4P3000A1.
Comments:
HVAC
Heat1.
Split Heat Pump (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
Page: 71 of 114
Building: 0060 - WASHINGTON DORMITORY (MALE)
Domestic hot water is provided by two 120 gallon electric water heaters. One water heater is a Bradford White model MII120-18-35F-39 and the other is a Richmond Perfect model ES-TES120- 18G.
Comments:
Cast Iron None None
Electric Water Cooler Hose Bibb Lavatory Service Sink Shower Urinal Water Closet (Flush Valve)
None
None None ABC Type Fire Extinguisher
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Split Heat Pump (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Cooling is provided by three split system heat pumps, data for which is provided under heating.Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
Page: 72 of 114
Building: 0060 - WASHINGTON DORMITORY (MALE)
Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the west side of the building, via a 600A pole-mounted main circuit breaker. From this circuit breaker the electrical service is routed to the building via underground cable and terminated in the 600A main panelboard with 600A main lugs only (MLO). The service equipment is located in the electrical/mechanical room.
FIRE ALARM
Comments: The fire alarm control panel is a Siemens FS-250. This panel is located in the RA office.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Comments: Recorded footcandle levels include natural light contribution.
High Intensity Discharge (HID) Comments: The exterior building-mounted light fixtures are controlled by a photocell.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Incandescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Corridors & Stairs
Equipment Rooms (Elec/Mech)
Storage Rooms
Laundry Room
Housing Lounge
Shower
Sleeping Rooms
Area Recommended Recorded Light Type
Battery Backup Battery Backup
Main Panelboard 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
ELECTRICAL SERVICES Number of Deficiencies = 2
Exterior Lighting1. Number of Deficiencies = 2
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 2
Type Location None None
There is no plausible means by which harmful levels of CO could enter sleeping rooms.
CARBON MONOXIDE DETECTION
LIGHTING
Detection Required
Page: 98 of 114
Building: 0074 - FORESTRY
INTERIOR FINISH
Concrete Vinyl Tile
Drywall
Metal Unit - Metal Frame
Mechanical Restroom
Ventilation Area Served
VERTICAL CIRCULATION
Concrete Stairs
Fixed - Aluminum Frame; Double Glazing;
Acoustical Tile Gypsum Board
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The inside unit is a Goodman model A42-15. The unit is located in the attic.Comments:
HVAC
Heat1.
Split Heat Pump (Air
Source)
Electric Resistance
Single Duct
Unit Heater
Refrigerant
None
Electric
Electric
Mechanical
Natural
None
None
Entire Building
Shop Area
Page: 99 of 114
Building: 0074 - FORESTRY
Domestic hot water is provided by a Richmond Perfect model 6E30-2 30-gallon water heater.Comments:
PVC None None
Electric Water Cooler Lavatory Sink Urinal Water Closet (Tank)
None
None None ABC Type Fire Extinguisher
Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the south side of the building, via a 400A pole-mounted disconnect switch. From this distribution panelboard the electrical service is routed to the building via underground cable and terminated in the 400A panelboard with 300A main circuit breaker (MCB).
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Heat Pump (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
High Intensity Discharge (HID) Comments: The exterior building-mounted light fixtures are controlled by a photocell.
Main Branch Panel 120/208V, 1-Phase, 3 Wire Branch Panel Only Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
The outside unit is a Goodman model CPKJ36-1AB.Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
Number of Deficiencies = 1FIRE PROTECTION
ELECTRICAL SERVICES
Exterior Lighting1. Number of Deficiencies = 1
Page: 100 of 114
Building: 0074 - FORESTRY
FIRE ALARM
Comments: The fire alarm control panel is a Simplex DS 9400I. This panel is located in the storage room.
Comments: The building is connected to the LAN.
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
T12 - Fluorescent
T12 - Fluorescent
T12 - Fluorescent
T12 - Fluorescent
Offices
Toilets
Storage Rooms
Vocational
Area Recommended Recorded Light Type
None Battery Backup
Emergency Exit
Number of Deficiencies = 1
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 2
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No N/ANo
BUILDING UTILITY METERING
Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good
Type Location N/A N/A
CARBON MONOXIDE DETECTION
Detection Required No
Number of Deficiencies = 0
IMPAIRMENT
Potentially Impaired
DOL Responded
DOL Determination
Potential Impaired Comments DOL Determination Discussion/Comments
Page: 107 of 114
Building: 0076 - STUDENT ACTIVITY CENTER
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall
Wood Units - Metal Frame
Mechanical Restroom
Ventilation Area Served
VERTICAL CIRCULATION
Concrete Stairs Metal Stairs Ramp Comments: The metal stairs pull down for attic access.
Fixed - Aluminum Frame; Double Glazing; Sliding - Aluminum Frame; Double Glazing;
Acoustical Tile Gypsum Board
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heating is provided by two gas-fired furnaces located in the attic. One serves the common areas, and one serves the offices. The furnaces are Lennox Pulse model CH22-65-1 and model CH23-65-1.
Comments:
HVAC
Heat1.
Gas-Fired Furnace
Single Duct None Electric Mechanical None Entire Building
Page: 108 of 114
Building: 0076 - STUDENT ACTIVITY CENTER
Domestic hot water is provided by a 20-gallon electric water heater.Comments:
PVC None None
Electric Water Cooler Lavatory Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the south side of the building, via a 400A pole-mounted disconnect switch. From this distribution panelboard the electrical service is routed to the building via underground cable and terminated in the 400A panelboard with 300A main circuit breaker (MCB).
Copper Copper Electric Building Water Softener No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Direct Expansion (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
Incandescent Comments: The exterior building-mounted light fixtures are controlled by a photocell.
Main Branch Panel 120/208V, 1-Phase, 3 Wire Branch Panel Only Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
The furnaces are provided with evaporator coils matched to Lennox outdoor air cooled condensing units. One is a model HS26-060-2P and and one is a model HS26-048-2P.
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
Number of Deficiencies = 1FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 1
Exterior Lighting1.
Page: 109 of 114
Building: 0076 - STUDENT ACTIVITY CENTER
FIRE ALARM
Comments: The fire alarm control panel is a Tyco-Maxis PS 2040FC. This panel is located in the residential manager's office.
Comments: The building is connected to the LAN.
Audible Alarm Control/Annunciator Panel Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None None
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
High Intensity Discharge (HID)
Offices
Corridors & Stairs
Lounges
Storage Rooms
Study Room
Area Recommended Recorded Light Type
None Battery Backup
Emergency Exit
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Interior Lighting2.
Emergency /Exit Lighting3.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoNo
BUILDING UTILITY METERING
Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good
Type Location N/A N/A
CARBON MONOXIDE DETECTION
Detection Required No
IMPAIRMENT
Page: 102 of 114
Building: 0075 - DISPENSARY
INTERIOR FINISH
Ceramic Tile Concrete Vinyl Tile
Drywall
Wood Unit - Metal Frame
Mechanical Restroom
Ventilation Area Served
VERTICAL CIRCULATION
Metal Stairs Ramp Comments: The metal stairs pull down for attic access.
Fixed - Wood Frame; Double Glazing; Sliding - Wood Frame; Double Glazing;
Acoustical Tile Gypsum Board
Exhaust Ventilation
Number of Deficiencies = 1
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The building is heated by three high efficiency gas furnaces located in the attic. All three furnaces are Trane model TXCO42HPCO.
Comments:
HVAC
Heat1.
Gas-Fired Furnace
Single Duct None Electric Mechanical None Entire Building
Ventilation2. Number of Deficiencies = 2
Page: 103 of 114
Building: 0075 - DISPENSARY
Domestic hot water is provided by a Richmond model TES85-18-G 80 gallon electric water heater.Comments:
Cast Iron None None
Electric Water Cooler Lavatory Shower/Bathtub Sink Water Closet (Flush Valve)
Gas (Natural)
Wet None ABC Type Fire Extinguisher
Comments: There is a sprinkler system in the attic of the building where the mechanical equipment is located.
Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the north side of the building, via a 400A pole-mounted disconnect switch. From this distribution panelboard the electrical service is routed to the building via underground cable and terminated in the 400A panelboard with 400A main circuit breaker (MCB).
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Direct Expansion (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
High Intensity Discharge (HID) Comments: Building-mounted lighting are controlled by astronomical time clock located in the electrical room.
Main Distribution Panel 120/208V, 1-Phase, 3 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
The three outside condensing units are Trane model TTB042D.Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 2
Exterior Lighting1.
Page: 104 of 114
Building: 0075 - DISPENSARY
FIRE ALARM
Comments: The fire alarm control panel is a Fire Lite MS 2410B. This panel is located in the lobby.
Comments: The building is connected to the LAN. The public address system is not connected and therefore not operational.
Audible Alarm Control Panel Flow Switch Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Corridors & Stairs
Equipment Rooms (Elec/Mech)
Reception
Toilets
Storage Rooms
Housing Lounge
Medical/Dental
Wards (Patient)
Area Recommended Recorded Light Type
Selected Lighting w/ Battery Battery Backup
Emergency Exit
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 1
COMMUNICATION
Electric Water Gas No NoNo
BUILDING UTILITY METERING
Type Location None None
There is no plausible means by which harmful levels of CO could enter sleeping rooms.
CARBON MONOXIDE DETECTION
Detection Required
Page: 80 of 114
Building: 0066 - VOCATIONAL SHOPS
INTERIOR FINISH
Carpet Concrete Vinyl Tile
Drywall Painted CMU Wood Paneling
Metal Unit - Metal Frame
VERTICAL CIRCULATION
Concrete Stairs Wood Stairs Comments: There are two sets of wood stairs and one of them is walled off and is unusable. This was done to eliminate unauthorized entry. The lower floor has its own entrance and exit doors as does the upper floor. Currently there is no interface between the functions of the upper and lower floors that requires interior circulation.
Fixed - Aluminum Frame; Double Glazing;
Exposed Structure Gypsum Board Plaster
Number of Deficiencies = 2
Windows6.
Floors1. Asbestos: Yes
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heating and cooling for the first floor is provided by through the wall heat pumps.
Offices and shop areas are heated by unit heaters.
Comments:
Comments:
HVAC
Heat1.
Packaged Heat Pump (Air
Source)
Electric Resistance
Through-The- Wall Unit
Unit Heater
None
None
Electric
Electric
Mechanical
Natural
None
None
Classrooms
Entire Building
Page: 81 of 114
Building: 0066 - VOCATIONAL SHOPS
Mechanical Restroom
Domestic hot water is provided by a Bradford White model M120V6S513 water heater.Comments:
PVC None None
Electric Water Cooler Fixed Emergency Eyewash Lavatory Urinal Water Closet (Flush Valve)
None
None None ABC Type Fire Extinguisher
Ventilation Area Served
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Packaged Direct
Expansion (Air Cooled)
Split Heat Pump (Air
Cooled)
Window Unit
Through-The- Wall Unit
None
None
Electric
Electric
Mechanical
Mechanical
None
None
Offices
Classrooms
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Exhaust Ventilation
Ventilation2.
System Type
Number of Deficiencies = 2
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
Page: 82 of 114
Building: 0066 - VOCATIONAL SHOPS
Comments: Electrical service of 120/240V to the building is provided from a pole-mounted utility-owned transformer bank, located at the north side of the building, via a 600A pole-mounted main distribution panel. From this distribution panelboard the electrical service is routed to the building via underground cable and terminated in the two 225A panelboard with 225A main circuit breaker (MCB0, and two 150A main lugs only panelboards.
FIRE ALARM
Comments: The fire alarm control panel is a Cerberus-Prytronics. This panel is located in the first-floor instructor office.
Comments: The public address system is not connected and therefore is not operational.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Control Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
High Intensity Discharge (HID) Comments: The exterior building-mounted light fixtures are controlled by a photocell.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Toilets
Storage Rooms
Classrooms
Vocational
Area Recommended Recorded Light Type
Battery Backup Battery Backup
Main Distribution Panel 120/240V, 1-Phase, 3 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
ELECTRICAL SERVICES Number of Deficiencies = 4
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 1
COMMUNICATION
Type Location N/A N/A
CARBON MONOXIDE DETECTION
LIGHTING
Detection Required
| Pages from 2015_00320_Final_Vol2_Part1 |
| Pages from 2015_00320_Final_Vol2_Part1-2 |
| Pages from 2015_00320_Final_Vol2_Part1-3 |
| Pages from 2015_00320_Final_Vol2_Part1-4 |
| Pages from 2015_00320_Final_Vol2_Part1-5 |
| Pages from 2015_00320_Final_Vol2_Part1-6 |
| Pages from 2015_00320_Final_Vol2_Part1-7 |
| Pages from 2015_00320_Final_Vol2_Part1-8 |
File details come from the government source that posted it. Updated .