Addendum 3.pdf

PDF 1 MB Posted

Attached to
Camp Dawson Building 244 Renovations (Construction)
Solicitation number
CRFQ 0603 ADJ2700000012 4
Issued by
Kanawha County, West Virginia

About this file

This is Addendum No. 3 to a Centralized Request for Quote (CRFQ) issued by the West Virginia Department of Administration Purchasing Division for construction renovations at Camp Dawson Building 244, managed by the West Virginia Army National Guard. The addendum modifies the original solicitation (CRFQ ADJ2700000012) by revising project specifications and drawings, with the bid opening date and time remaining September 8, 2026, at 1:30 p.m. EST. Key modifications include revisions to door hardware specifications (Section 087100), replacements of sheets A101, A302, and A601, and additions to the general notes regarding kitchen equipment relocation and HVAC emergency shutdown pushbuttons. The mandatory pre-bid meeting was held on August 18, 2026, at 1:00 p.m. EST, and vendor technical questions were due by August 27, 2026, at 11:00 a.m. EST. The project scope encompasses labor, materials, and associated costs to complete renovations to Building 244, with two add alternate line items for replacement of kitchen hoods (Item 2) and replacement of a walk-in cooler/freezer with foundations, slab, and vestibule (Item 3).

The solicitation requires vendors to acknowledge receipt of all addenda and submit acknowledgment forms with their bids, with failure to do so potentially resulting in bid disqualification. Door hardware specifications are detailed extensively, including requirements for hinges, locks, exit devices, closers, cylinders, and keying systems from scheduled manufacturers such as Schlage, Von Duprin, Ives, LCN, and Zero International. The project involves coordination with multiple trades, including electrical systems for electrified hardware, and compliance with fire-rated door assembly standards, accessibility requirements, and various national standards (NFPA, ANSI, UL). Bidders must be qualified architectural hardware suppliers with minimum five years of experience and must employ or engage certified Architectural Hardware Consultants. All bid submissions should be directed to the Department of Administration Purchasing Division at 2019 Washington Street East, Charleston, WV 25305, with inquiries directed to buyer David H. Pauline at 304-558-0067 or david.h.pauline@wv.gov.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date Printed: Aug 24, 2026 Page: 1 FORM ID: WV-PRC-CRFQ-002 2020/05

Department of Administration Purchasing Division 2019 Washington Street East Post Office Box 50130 Charleston, WV 25305-0130

State of West Virginia Centralized Request for Quote

Construction

Proc Folder: 2040316 Reason for Modification:

Doc Description: Camp Dawson Building 244 Renovations (Construction) Addendum No. 3

Proc Type: Central Purchase Order

Date Issued Solicitation Closes Solicitation No Version

2026-08-24 2026-09-08 13:30 CRFQ 0603 ADJ2700000012 4

BID RECEIVING LOCATION

BID CLERK

DEPARTMENT OF ADMINISTRATION

PURCHASING DIVISION

2019 WASHINGTON ST E

CHARLESTON WV 25305

US

VENDOR

Vendor Customer Code:

Vendor Name :

Address :

Street :

City :

State : Country : Zip :

Principal Contact :

Vendor Contact Phone: Extension:

FOR INFORMATION CONTACT THE BUYER

David H Pauline 304-558-0067 david.h.pauline@wv.gov

Vendor Signature X FEIN# DATE

All offers subject to all terms and conditions contained in this solicitation

Date Printed: Aug 24, 2026 Page: 2 FORM ID: WV-PRC-CRFQ-002 2020/05

ADDITIONAL INFORMATION

Addendum No. 3

To revise the Specifications of the project, see attached.

To revise the Drawings of the project, see attached.

The Bid Opening date & time remains September 8, 2026, at 1:30 pm EST.

No other changes.

INVOICE TO SHIP TO

ADJUTANT GENERALS

OFFICE

CAMP DAWSON ARMY

TRAINING SITE

1707 COONSKIN DR 240 ARMY RD

CHARLESTON WV KINGWOOD WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 1 Building 244 Renovations (Construction)

Comm Code Manufacturer Specification Model #

72000000

Extended Description:

To provide Labor, materials and all associated costs to complete renovations to Building 244 at Camp Dawson per the attached specifications and drawings.

INVOICE TO SHIP TO

ADJUTANT GENERALS

OFFICE

CAMP DAWSON ARMY

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 2 ADD Alternate # 1- Replacement of Kitchen

Hoods

Comm Code Manufacturer Specification Model #

72000000

Extended Description:

BID Item #2- ADD Alternate # 1- Replacement of Kitchen Hoods as described in the project drawings and specifications.

Date Printed: Aug 24, 2026 Page: 3 FORM ID: WV-PRC-CRFQ-002 2020/05

INVOICE TO SHIP TO

ADJUTANT GENERALS

OFFICE

CAMP DAWSON ARMY

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 3 ADD Alternate # 2- Replacement of Walk-In cooler/freezer

Comm Code Manufacturer Specification Model #

72000000

Extended Description:

BID Item #3- ADD Alternate # 2- Replacement of the walk-in cooler/freezer with foundations, slab, and vestibule as described in the project drawings and specifications.

SCHEDULE OF EVENTS

Line Event Event Date 1 Mandatory Pre-bid Meeting At 1:00 pm EST. 2026-08-18 2 Vendor Technical Questions Due By 11:00 am EST. 2026-08-27

SOLICITATION NUMBER: CRFQ ADJ2700000012

Addendum Number: 3

The purpose of this addendum is to modify the solicitation identified as (“ADJ2700000012”) to reflect the change(s) identified and described below.

Applicable Addendum Category:

☐ Modify bid opening date and time.

☒ Modify specifications of product or service being sought.

☐ Attachment of vendor questions and responses.

☐ Attachment of pre-bid sign-in sheet.

☐ Correction of error.

☒ Other.

Description of Modification to Solicitation:

To revise the Specifications of the project, see attached.

To revise the Drawings of the project, see attached

The Bid Opening date & time remains September 8, 2026, at 1:30 pm EST.

No other changes.

Additional Documentation: Documentation related to this Addendum (if any) has been included herewith as Attachment A and is specifically incorporated herein by reference.

Terms and Conditions:

1. All provisions of the Solicitation and other addenda not modified herein shall remain in full force and effect.

2. Vendor should acknowledge receipt of all addenda issued for this Solicitation by completing an Addendum Acknowledgment, a copy of which is included herewith. Failure to acknowledge addenda may result in bid disqualification. The addendum acknowledgement should be submitted with the bid to expedite document processing.

DEPARTMENT OF THE ARMY

CONSTRUCTION AND FACILITIES MANAGEMENT OFFICE

JOINT FORCES HEADQUARTERS WEST VIRGINIA

1707 COONSKIN DRIVE

CHARLESTON, WEST VIRGINIA 25311-1026

8/21/26

ADDENDUM NO. 3 CRFQ- ADJ2700000012

RE: Construction: WVANG Camp Dawson Building 244 Renovation

TO: Prospective Bidders

FROM: West Virginia Army National Guard

NOTE: This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents.

PART 1 - INFORMATION FOR BIDDERS

To revise the Specifications of the project.

To revise the Drawings of the project.

WVANG Camp Dawson

Building 244 Renovation

Addendum 03

Montum Architecture, LLC

55 ER Path, Keyser, WV 26726 304-276-7151 tom@montumarch.com montumarch.com

DATE: August 18, 2026

TO: ALL BIDDERS

GENERAL NOTES:

1. This Addendum shall be incorporated as a part of the Request For Bid Solicitation describing the services for the above referenced project.

2. All Bidders shall acknowledge receipt of this Addendum on the Bid Form of Proposal. Failure to do so may be cause for rejection of Bid.

3. This Addendum supersedes and supplements all portions of the proposal documents with which it conflicts. These Revisions supersede all previous instructions pertaining to these items.

I. Revisions to the Specifications:

087100 – Door Hardware: Replace section 087100 with the attached 087100.

II. Revisions to the Drawings:

Sheet A001 - General Notes: Add note 4: Contractor to disconnect and relocate all kitchen equipment during renovations. Storage location will either be within the dining area or a location designated at Camp Dawson. Some kitchen equipment will be replaced in-kind under separate contract. Contractor will install reused and new in-kind kitchen equipment.

Sheet A101: Replace sheet A101 with the attached A101.

Sheet A302: Replace sheet A302 with the attached A302.

Sheet A601: Replace sheet A601 with the attached A601.

Sheet M101 - General Notes: Add note 22: Install (2) emergency shutdown pushbuttons w/ hinged cover. Pushbuttons are to shut down all HVAC equipment. Install placard over pushbutton stating “HVAC Emergency

Shutdown”. One pushbutton will be placed in room 101 – Dining and one will be in 103 – Kitchen with the final locations to be determined by the Owner. Provide relays, and dedicated control power source, as necessary to break the control

WVANG Camp Dawson

Addendum 03

55 ER Path, Keyser, WV 26726 304-276-7151 tom@montumarch.com montumarch.com power circuits on RTU-1, MAU-1, ODU-1, & all exhaust fan motor starters, causing all to shut down.

III. Questions:

None.

IV. Substitution Requests

None.

Issued August 18, 2026

Tom Pritts, AIA

WV Army National Guard

Camp Dawson

DOOR HARDWARE 087100-1

08/14/2026

SECTION 087100 - DOOR HARDWARE

PART 1 - GENERAL

1.01 SUMMARY

A. Section includes:

1. Mechanical and electrified door hardware

B. Section excludes:

1. Windows

2. Cabinets (casework), including locks in cabinets

3. Signage

4. Toilet accessories

5. Overhead doors

C. Related Sections:

1. Division 01 "General Requirements" sections for Allowances, Alternates, Owner

Furnished Contractor Installed, Project Management and Coordination.

2. Division 06 Section ''Rough Carpentry''

3. Division 06 Section ''Finish Carpentry''

4. Division 07 Section ''Joint Sealants'' for sealant requirements applicable to threshold installation specified in this section.

5. Division 08 Sections:

a. ''Metal Doors and Frames''

b. ''Flush Wood Doors''

c. ''Stile and Rail Wood Doors''

d. ''Interior Aluminum Doors and Frames''

e. ''Aluminum-Framed Entrances and Storefronts''

f. ''Stainless Steel Doors and Frames''

g. ''Special Function Doors''

h. ''Entrances''

1.02 REFERENCES

A. UL LLC

1. UL 10B - Fire Test of Door Assemblies

2. UL 10C - Positive Pressure Test of Fire Door Assemblies

3. UL 1784 - Air Leakage Tests of Door Assemblies

4. UL 305 - Panic Hardware

B. DHI - Door and Hardware Institute

1. Sequence and Format for the Hardware Schedule

2. Recommended Locations for Builders Hardware

3. Keying Systems and Nomenclature

4. Installation Guide for Doors and Hardware

DOOR HARDWARE 087100-2

C. NFPA – National Fire Protection Association

1. NFPA 70 – National Electric Code

2. NFPA 80 – Standard for Fire Doors and Other Opening Protectives

3. NFPA 101 – Life Safety Code

4. NFPA 105 – Smoke and Draft Control Door Assemblies

5. NFPA 252 – Fire Tests of Door Assemblies

D. ANSI - American National Standards Institute

1. ANSI A117.1 – 2017 Edition – Accessible and Usable Buildings and Facilities

2. ANSI/BHMA A156.1 - A156.29, and ANSI/BHMA A156.31 - Standards for Hardware and Specialties

3. ANSI/BHMA A156.28 - Recommended Practices for Keying Systems

4. ANSI/WDMA I.S. 1A - Interior Architectural Wood Flush Doors

5. ANSI/SDI A250.8 - Standard Steel Doors and Frames

1.03 SUBMITTALS

A. General:

1. Submit in accordance with Conditions of Contract and Division 01 Submittal Procedures.

2. Prior to forwarding submittal:

a. Review drawings and Sections from related trades to verify compatibility with specified hardware.

b. Highlight, encircle, or otherwise specifically identify on submittals: deviations from

Contract Documents, issues of incompatibility or other issues which may detrimentally affect the Work.

B. Action Submittals:

1. Product Data: Submit technical product data for each item of door hardware, installation instructions, maintenance of operating parts and finish, and other information necessary to show compliance with requirements.

2. Samples for Verification: If requested by Architect, submit production sample of requested door hardware unit in finish indicated and tagged with full description for coordination with schedule.

a. Samples will be returned to supplier. Units that are acceptable to Architect may, after final check of operations, be incorporated into Work, within limitations of key coordination requirements.

3. Door Hardware Schedule:

a. Submit concurrent with submissions of Product Data, Samples, and Shop Drawings.

Coordinate submission of door hardware schedule with scheduling requirements of other work to facilitate fabrication of other work critical in Project construction schedule.

b. Submit under direct supervision of a Door Hardware Institute (DHI) certified Architectural Hardware Consultant (AHC) or Door Hardware Consultant (DHC) with hardware sets in vertical format as illustrated by Sequence of Format for the Hardware Schedule published by DHI.

c. Indicate complete designations of each item required for each opening, include:

1) Door Index: door number, heading number, and Architect's hardware set number.

2) Quantity, type, style, function, size, and finish of each hardware item.

DOOR HARDWARE 087100-3

3) Name and manufacturer of each item.

4) Fastenings and other pertinent information.

5) Location of each hardware set cross-referenced to indications on Drawings.

6) Explanation of all abbreviations, symbols, and codes contained in schedule.

7) Mounting locations for hardware.

8) Door and frame sizes and materials.

9) Degree of door swing and handing.

10) Operational Description of openings with electrified hardware covering egress, ingress (access), and fire/smoke alarm connections.

4. Key Schedule:

a. After Keying Conference, provide keying schedule that includes levels of keying, explanations of key system's function, key symbols used, and door numbers controlled.

b. Use ANSI/BHMA A156.28 ''Recommended Practices for Keying Systems'' as guideline for nomenclature, definitions, and approach for selecting optimal keying system.

c. Provide 3 copies of keying schedule for review prepared and detailed in accordance with referenced DHI publication. Include schematic keying diagram and index each key to unique door designations.

d. Index keying schedule by door number, keyset, hardware heading number, cross keying instructions, and special key stamping instructions.

e. Provide one complete bitting list of key cuts and one key system schematic illustrating system usage and expansion. Forward bitting list, key cuts and key system schematic directly to Owner, by means as directed by Owner.

f. Prepare key schedule by or under supervision of supplier, detailing Owner's final keying instructions for locks.

C. Informational Submittals:

1. Provide Qualification Data for Supplier, Installer and Architectural Hardware Consultant.

2. Provide Product Data:

a. Certify that door hardware approved for use on types and sizes of labeled fire-rated doors complies with listed fire-rated door assemblies.

b. Include warranties for specified door hardware.

D. Closeout Submittals:

1. Operations and Maintenance Data: Provide in accordance with Division 01 and include:

a. Complete information on care, maintenance, and adjustment; data on repair and replacement parts, and information on preservation of finishes.

b. Catalog pages for each product.

c. Final approved hardware schedule edited to reflect conditions as installed.

d. Final keying schedule

e. Copy of warranties including appropriate reference numbers for manufacturers to identify project.

f. As-installed wiring diagrams for each opening connected to power, both low voltage and 110 volts.

E. Inspection and Testing:

1. Submit written reports to the Owner and Authority Having Jurisdiction (AHJ) of the results of functional testing and inspection for:

a. Fire door assemblies, in compliance with NFPA 80.

DOOR HARDWARE 087100-4

b. Required egress door assemblies, in compliance with NFPA 101.

1.04 QUALITY ASSURANCE

A. Qualifications and Responsibilities:

1. Supplier: Recognized architectural hardware supplier with a minimum of 5 years documented experience supplying both mechanical and electromechanical door hardware similar in quantity, type, and quality to that indicated for this Project. Supplier to be recognized as a factory direct distributor by the manufacturer of the primary materials with a warehousing facility in the Project’s vicinity. Supplier to have on staff, a certified

Architectural Hardware Consultant (AHC) or Door Hardware Consultant (DHC) available to Owner, Architect, and Contractor, at reasonable times during the Work for consultation.

2. Installer: Qualified tradesperson skilled in the application of commercial grade hardware with experience installing door hardware similar in quantity, type, and quality as indicated for this Project.

3. Architectural Hardware Consultant: Person who is experienced in providing consulting services for door hardware installations that are comparable in material, design, and extent to that indicated for this Project and meets these requirements:

a. For door hardware: DHI certified AHC or DHC.

b. Can provide installation and technical data to Architect and other related subcontractors.

c. Can inspect and verify components are in working order upon completion of installation.

d. Capable of producing wiring diagram and coordinating installation of electrified hardware with Architect and electrical engineers.

4. Single Source Responsibility: Obtain each type of door hardware from single manufacturer.

B. Certifications:

1. Fire-Rated Door Openings:

a. Provide door hardware for fire-rated openings that complies with NFPA 80 and requirements of authorities having jurisdiction.

b. Provide only items of door hardware that are listed products tested by UL LLC, Intertek Testing Services, or other testing and inspecting organizations acceptable to authorities having jurisdiction for use on types and sizes of doors indicated, based on testing at positive pressure and according to NFPA 252 or UL 10C and in compliance with requirements of fire-rated door and door frame labels.

2. Smoke and Draft Control Door Assemblies:

a. Provide door hardware that meets requirements of assemblies tested according to

UL 1784 and installed in compliance with NFPA 105

b. Comply with the maximum air leakage of 0.3 cfm/sq. ft. (3 cu. m per minute/sq. m) at tested pressure differential of 0.3-inch wg (75 Pa) of water.

3. Electrified Door Hardware

a. Listed and labeled as defined in NFPA 70, Article 100, by testing agency acceptable to authorities having jurisdiction.

4. Accessibility Requirements:

DOOR HARDWARE 087100-5

a. Comply with governing accessibility regulations cited in ''REFERENCES'' article 087100, 1.02.D3 herein for door hardware on doors in an accessible route. This project must comply with all Federal Americans with Disability Act regulations and all Local Accessibility Regulations.

C. Pre-Installation Meetings

1. Keying Conference

a. Incorporate keying conference decisions into final keying schedule after reviewing door hardware keying system including:

1) Function of building, flow of traffic, purpose of each area, degree of security required, and plans for future expansion.

2) Preliminary key system schematic diagram.

3) Requirements for key control system.

4) Requirements for access control.

5) Address for delivery of keys.

2. Pre-installation Conference

a. Review and finalize construction schedule and verify availability of materials, Installer's personnel, equipment, and facilities needed to make progress and avoid delays.

b. Inspect and discuss preparatory work performed by other trades.

c. Inspect and discuss electrical roughing-in for electrified door hardware.

d. Review sequence of operation for each type of electrified door hardware.

e. Review required testing, inspecting, and certifying procedures.

f. Review questions or concerns related to proper installation and adjustment of door hardware.

3. Electrified Hardware Coordination Conference:

a. Prior to ordering electrified hardware, schedule and hold meeting to coordinate door hardware with security, electrical, doors and frames, and other related suppliers.

1.05 DELIVERY, STORAGE, AND HANDLING

A. Inventory door hardware on receipt and provide secure lock-up for hardware delivered to Project site. Promptly replace products damaged during shipping

B. Tag each item or package separately with identification coordinated with final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item or package. Deliver each article of hardware in manufacturer's original packaging.

C. Maintain manufacturer-recommended environmental conditions throughout storage and installation periods.

D. Provide secure lock-up for door hardware delivered to Project. Control handling and installation of hardware items so that completion of Work will not be delayed by hardware losses both before and after installation.

E. Handle hardware in manner to avoid damage, marring, or scratching. Correct, replace or repair products damaged during Work. Protect products against malfunction due to paint, solvent, cleanser, or any chemical agent.

F. Deliver keys to manufacturer of key control system for subsequent delivery to Owner.

DOOR HARDWARE 087100-6

1.06 COORDINATION

A. Coordinate layout and installation of floor-recessed door hardware with floor construction.

Cast anchoring inserts into concrete.

B. Installation Templates: Distribute for doors, frames, and other work specified to be factory or shop prepared. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.

C. Security: Coordinate installation of door hardware, keying, and access control with Owner's security consultant.

D. Electrical System Roughing-In: Coordinate layout and installation of electrified door hardware with connections to power supplies and building safety and security systems.

1.07 WARRANTY

A. Manufacturer's standard form in which manufacturer agrees to repair or replace components of door hardware that fail in materials or workmanship within published warranty period.

1. Warranty does not cover damage or faulty operation due to improper installation, improper use or abuse.

2. Warranty Period: Beginning from date of Substantial Completion, for durations indicated in manufacturer's published listings.

a. Mechanical Warranty

1) Locks 10 years

2) Exit Devices 10 years

3) Closers 30 years

1.08 MAINTENANCE

A. Furnish complete set of special tools required for maintenance and adjustment of hardware, including changing of cylinders.

B. Turn over unused materials to Owner for maintenance purposes.

PART 2 - PRODUCTS

2.01 MANUFACTURERS

A. The Owner requires use of certain products for their unique characteristics and project suitability to ensure continuity of existing and future performance and maintenance standards. After investigating available product offerings, the Awarding Authority has elected to prepare proprietary specifications. These products are specified with the notation: ''No Substitute.''

1. Where ''No Substitute'' is noted, submittals and substitution requests for other products will not be considered.

DOOR HARDWARE 087100-7

B. Approval of alternate manufacturers and/or products other than those listed as ''Scheduled Manufacturer'' or ''Acceptable Manufacturers'' in the individual article for the product category are only to be considered by official substitution request in accordance with section 01 25 00.

C. Approval of products from manufacturers indicated in ''Acceptable Manufacturers'' is contingent upon those products providing all functions and features and meeting all requirements of scheduled manufacturer's product.

D. Where specified hardware is not adaptable to finished shape or size of members requiring hardware, furnish suitable types having same operation and quality as type specified, subject to Architect's approval.

2.02 MATERIALS

A. Fabrication

1. Provide door hardware manufactured to comply with published templates generally prepared for machine, wood, and sheet metal screws. provide screws according to manufacturer’s recognized installation standards for application intended.

2. Finish exposed screws to match hardware finish, or, if exposed in surfaces of other work, to match finish of this other work including prepared for paint surfaces to receive painted finish.

3. Provide concealed fasteners wherever possible for hardware units exposed when door is closed. Coordinate with “Metal Doors and Frames”, “Flush Wood Doors”, “Stile and Rail

Wood Doors” to ensure proper reinforcements. Advise the Architect where visible fasteners, such as thru bolts, are required.

B. Provide screws, bolts, expansion shields, drop plates and other devices necessary for hardware installation.

1. Where fasteners are exposed to view: Finish to match adjacent door hardware material.

2.03 CONTINUOUS HINGES

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Select

b. Best

B. Requirements:

1. Provide aluminum geared continuous hinges conforming to ANSI/BHMA A156.26, Grade 1.

2. Provide aluminum geared continuous hinges, where specified in the hardware sets, fabricated from 6063-T6 aluminum.

3. Provide split nylon bearings at each hinge knuckle for quiet, smooth, self-lubricating operation.

DOOR HARDWARE 087100-8

4. Provide hinges capable of supporting door weights up to 450 pounds, and successfully tested for 1,500,000 cycles.

5. On fire-rated doors, provide aluminum geared continuous hinges classified for use on rated doors by testing agency acceptable to authority having jurisdiction.

6. Provide aluminum geared continuous hinges with electrified option scheduled in the hardware sets. Provide with number and gage of wires enough to accommodate electric function of specified hardware.

7. Provide hinges 1 inch (25 mm) shorter in length than nominal height of door, unless otherwise noted or door details require shorter length and with symmetrical hole pattern.

2.04 FLUSH BOLTS

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Requirements:

1. Provide automatic, constant latching, and manual flush bolts with forged bronze or stainless-steel face plates, extruded brass levers, and with wrought brass guides and strikes. Provide 12 inch (305 mm) steel or brass rods at doors up to 90 inches (2286 mm) in height. For doors over 90 inches (2286 mm) in height increase top rods by 6 inches (152 mm) for each additional 6 inches (152 mm) of door height. Provide dust-proof strikes at each bottom flush bolt.

2.05 MORTISE LOCKS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage L9000 series

2. Acceptable Manufacturers and Products:

a. No Substitute

B. Requirements:

1. Provide mortise locks conforming to ANSI/BHMA A156.13 Series 1000, Grade 1, and UL Listed for 3-hour fire doors.

2. Indicators: Where specified, provide indicator window measuring a minimum 2-inch x 1/2 inch with 180-degree visibility. Provide messages color-coded with full text and/or symbols, as scheduled, for easy visibility.

3. Provide locks manufactured from heavy gauge steel, containing components of steel with a zinc dichromate plating for corrosion resistance.

4. Provide lock case that is multi-function and field reversible for handing without opening case. Cylinders: Refer to “KEYING” article, herein.

DOOR HARDWARE 087100-9

5. Provide locks with standard 2-3/4 inches (70 mm) backset with full 3/4 inch (19 mm) throw stainless steel mechanical anti-friction latchbolt. Provide deadbolt with full 1-inch (25 mm) throw, constructed of stainless steel.

6. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim.

7. Provide electrified options as scheduled in the hardware sets. Where scheduled, provide switches and sensors integrated into the locks and latches. Provide motor based electrified and motor based latch retraction locksets that comply with the following requirements:

a. Universal input voltage – single chassis accepts 12 or 24VDC to allow for changes in the field without changing lock chassis.

b. Fail Safe/Fail Secure – changing mode between electrically locked (fail safe) and electrically unlocked (fail secure) is field selectable without opening the lock case

c. Low maximum current draw – maximum 0.4 amps (Lever control) and maximum 2.0 amps (Latch retraction) to allow for multiple locks on a single power supply.

d. Low holding current (Lever control or latch retraction) – maximum 0.01 amps to produce minimal heat, eliminate “hot levers” in electrically locked applications and motorized latch retraction applications, and to provide reliable operation in wood doors that provide minimal ventilation and air flow.

e. Connections – provide quick-connect Molex system standard.

8. (OPTION Key Override) Provide locks with a key override feature built into the chassis that allows the outside key to retract the deadbolt and/or latchbolt, overriding the inside thumbturn when it is being held in the locked position - where the XL13-439 option is specified in the hardware sets.

9. Lever Trim: Solid brass, bronze, or stainless steel, cast or forged in design specified, with wrought roses and external lever spring cages. Provide thru-bolted levers with 2-piece spindles.

a. Lever Design: 17.

2.06 EXIT DEVICES

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Von Duprin 99/33A series

2. Acceptable Manufacturers and Products:

a. No Substitute

B. Requirements:

1. Provide exit devices tested to ANSI/BHMA A156.3 Grade 1 and UL listed for Panic Exit or Fire Exit Hardware.

2. Cylinders: Refer to ''KEYING'' article, herein.

3. Provide grooved touchpad type exit devices, fabricated from brass, bronze, stainless steel, or aluminum, plated to standard architectural finishes to match the balance of door hardware.

4. Touchpad must extend a minimum of one-half of the door width. No plastic inserts are allowed in touchpads.

5. Provide exit devices with a deadlatching feature for security and for future addition of alarm kits and/or other electrified requirements.

DOOR HARDWARE 087100-10

6. Provide exit devices at pool gates with weather-resistant components that can withstand harsh conditions of various climates and corrosive cleaners used in outdoor pool environments.

7. Provide flush end caps for exit devices.

8. Provide exit devices with manufacturers’ approved strikes.

9. Provide exit devices cut to the door width and height. Install exit devices at a height recommended by the exit device manufacturer, allowable by governing building codes, and approved by the Architect.

10. Mount the mechanism case flush on the face of the doors or provide spacers to fill gaps behind the devices. Where glass trim or molding projects off the face of the door, provide glass bead kits.

11. Provide cylinder or hex-key dogging as specified at non-fire-rated openings.

12. Removable Mullions: 2 inches (51 mm) x 3 inches (76 mm) steel tube. Where scheduled as keyed removable mullion, provide a type that can be removed by use of a keyed cylinder, which is self-locking when reinstalled.

13. Provide factory-drilled weep holes for exit devices used in full exterior applications, highly corrosive areas, and where noted in hardware sets.

14. Provide electrified options as scheduled.

15. Top latch mounting: double- or single-tab mount for steel doors, face mount for aluminum doors, eliminating the requirement of tabs, and double tab mount for wood doors.

16. Accessibility: Require not more than 5 lb. to retract the latchbolt, per CBC 2019 11B-

404.2.7 and 11B-309.4.

a. Mechanical method: Von Duprin AX feature, where touchpad directly retracts the latchbolt with 5 lb. or less of force. Provide testing lab certification confirming that the mechanical device is independent third-party tested to meet this 5 lb. requirement.

b. Electrical method: Von Duprin’s RX-QEL feature, where lightly pressing the touchpad with 5 lb. or less of force closes an electric switch, activating quiet electric latch retraction.

17. Provide exit devices with optional trim designs to match other lever and pull designs used on the project.

a. Provide levers that return to within 1/2 inch (13 mm) of the door face.

2.07 CYLINDERS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage Primus XP

2. Acceptable Manufacturers and Products:

a. No Substitute

B. Requirements:

1. Provide cylinders/cores, compliant with ANSI/BHMA A156.5; latest revision; cylinder face finished to match lockset, manufacturer’s series as indicated. Refer to “KEYING” article, herein.

2. Provide cylinders in the below-listed configuration(s), distributed throughout the Project as indicated.

a. High Security: dual-locking cylinder with permanent core requiring restricted, patented keyway. Dual-locking mechanism with interlocking finger pin(s) to check for patented features on keys.

DOOR HARDWARE 087100-11

3. Patent Protection: Cylinders/cores requiring use of restricted, patented keys, patent protected.

4. Nickel silver bottom pins.

2.08 KEYING

A. Scheduled System:

1. Existing factory registered system:

a. Provide cylinders/cores keyed into Owner’s existing factory registered keying system.

Comply with guidelines in ANSI/BHMA A156.28, incorporating decisions made at keying conference.

B. Requirements:

1. Construction Keying:

a. Replaceable Construction Cores.

1) Provide temporary construction cores replaceable by permanent cores, furnished in accordance with the following requirements.

a) 3 construction control keys

b) 12 construction change (day) keys.

2) Owner or Owner’s Representative will replace temporary construction cores with permanent cores.

2. Permanent Keying:

a. Provide permanent cylinders/cores keyed by the manufacturer according to the following key system.

1) Master Keying system as directed by the Owner.

b. Forward bitting list and keys separately from cylinders, by means as directed by Owner. Failure to comply with forwarding requirements will be cause for replacement of cylinders/cores involved at no additional cost to Owner.

c. Provide keys with the following features:

1) Material: Nickel silver; minimum thickness of .107-inch (2.3mm)

2) Patent Protection: Keys and blanks protected by one or more utility patent(s).

3) Geographically Exclusive: Where High Security or Security cylinders/cores are indicated, provide nationwide, geographically exclusive key system complying with the following restrictions.

d. Identification:

1) Mark permanent cylinders/cores and keys with applicable blind code for identification. Do not provide blind code marks with actual key cuts.

2) Identification stamping provisions must be approved by the Architect and Owner.

3) Stamp cylinders/cores and keys with Owner’s unique key system facility code as established by the manufacturer; key symbol and embossed or stamped with “DO NOT DUPLICATE” along with the “PATENTED” or patent number to enforce the patent protection.

4) Failure to comply with stamping requirements will be cause for replacement of keys involved at no additional cost to Owner.

5) Forward permanent cylinders/cores to Owner, separately from keys, by means as directed by Owner.

e. Quantity: Furnish in the following quantities.

1) Permanent Control Keys: 3.

2) Master Keys: 6.

3) Change (Day) Keys: 3 per cylinder/core that is keyed differently

DOOR HARDWARE 087100-12

4) Key Blanks: Quantity as determined in the keying meeting.

2.09 KEY CONTROL SYSTEM

A. Manufacturers:

1. Scheduled Manufacturer:

a. Telkee

2. Acceptable Manufacturers:

a. HPC

b. Lund

B. Requirements:

1. Provide key control system, including envelopes, labels, tags with self-locking key clips, receipt forms, 3-way visible card index, temporary markers, permanent markers, and standard metal cabinet, all as recommended by system manufacturer, with capacity for 150% of number of locks required for Project.

a. Provide complete cross index system set up by hardware supplier, and place keys on markers and hooks in cabinet as determined by final key schedule.

b. Provide hinged-panel type cabinet for wall mounting.

2.10 DOOR CLOSERS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. LCN 4040XP series

2. Acceptable Manufacturers and Products:

a. No Substitute

B. Requirements:

1. Provide door closers conforming to ANSI/BHMA A156.4 Grade 1 requirements by BHMA certified independent testing laboratory. ISO 9000 certify closers. Stamp units with date of manufacture code.

2. Provide door closers with fully hydraulic, full rack and pinion action with high strength cast iron cylinder, and full complement bearings at shaft.

3. Cylinder Body: 1-1/2-inch (38 mm) diameter piston with 5/8-inch (16 mm) diameter double heat-treated pinion journal. QR code with a direct link to maintenance instructions.

4. Hydraulic Fluid: Fireproof, passing requirements of UL10C, and requiring no seasonal closer adjustment for temperatures ranging from 120 degrees F to -30 degrees F.

5. Spring Power: Continuously adjustable over full range of closer sizes, and providing reduced opening force as required by accessibility codes and standards. Provide snap-on cover clip, with plastic covers, that secures cover to spring tube.

6. Hydraulic Regulation: By tamper-proof, non-critical valves, with separate adjustment for latch speed, general speed, and backcheck. Provide graphically labelled instructions on the closer body adjacent to each adjustment valve. Provide positive stop on reg valve that prevents reg screw from being backed out.

DOOR HARDWARE 087100-13

7. Provide closers with solid forged steel main arms and factory assembled heavy-duty forged forearms for parallel arm closers.

8. Pressure Relief Valve (PRV) Technology: Not permitted.

9. Finish for Closer Cylinders, Arms, Adapter Plates, and Metal Covers: Powder coating finish which has been certified to exceed 100 hours salt spray testing as described in ANSI Standard A156.4 and ASTM B117, or has special rust inhibitor (SRI).

10. Provide special templates, drop plates, mounting brackets, or adapters for arms as required for details, overhead stops, and other door hardware items interfering with closer mounting.

11. Closers shall be capable of being upgraded by adding modular mechanical or electronic components in the field.

2.11 DOOR TRIM

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Requirements:

1. Provide push plates, push bars, pull plates, pulls, and hands-free reversible door pulls with diameter and length as scheduled.

2.12 PROTECTION PLATES

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. No Substitute

b. Burns

c. Trimco

B. Requirements:

1. Provide protection plates with a minimum of 0.050 inch (1 mm) thick, beveled four edges as scheduled. Furnish with sheet metal or wood screws, finished to match plates.

2. Sizes plates 2 inches (51 mm) less width of door on single doors, pairs of doors with a mullion, and doors with edge guards. Size plates 1 inch (25 mm) less width of door on pairs without a mullion or edge guards.

3. At fire rated doors, provide protection plates over 16 inches high with UL label.

2.13 OVERHEAD STOPS AND OVERHEAD STOP/HOLDERS

DOOR HARDWARE 087100-14

A. Manufacturers:

1. Scheduled Manufacturers:

a. Glynn-Johnson

2. Acceptable Manufacturers:

a. Rixson

b. Sargent

B. Requirements:

1. Provide overhead stop at any door where conditions do not allow for a wall stop or floor stop presents tripping hazard.

2.14 DOOR STOPS AND HOLDERS

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Provide door stops at each door leaf:

1. Provide wall stops wherever possible. Provide concave type where lockset has a push button of thumbturn.

2. Where a wall stop cannot be used, provide universal floor stops.

3. Where wall or floor stop cannot be used, provide overhead stop.

4. Provide roller bumper where doors open into each other and overhead stop cannot be used.

2.15 SILENCERS

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Requirements:

1. Provide ''push-in'' type silencers for hollow metal or wood frames.

2. Provide one silencer per 30 inches (762 mm) of height on each single frame, and two for each pair frame.

3. Omit where gasketing is specified.

DOOR HARDWARE 087100-15

2.16 THRESHOLDS, SEALS, DOOR SWEEPS, AUTOMATIC DOOR BOTTOMS, AND

GASKETING

A. Scheduled Manufacturer:

1. Zero International

B. Acceptable Manufacturers:

1. Reese

2. Pemko

C. Seals and Gasketing: Provide continuous gasketing on exterior openings, to the head and jambs, forming a continuous seal between the door and the frame. Provide smoke, light, or sound gasketing on interior doors where indicated.

1. Provide self-tapping fasteners for aluminum extruded gasketing being applied to hollow metal frames.

a. Provide non-corrosive fasteners for all exterior applications.

b. Provide security fasteners where indicated.

2. Provide neoprene, EPDM, silicone, or nylon brush inserts as specified in hardware sets.

Provide non brush inserts of solid or sponge cell, as specified in hardware sets. Vinyl inserts are not allowed except where specified in hardware sets.

D. Smoke Labeled Gasketing: At all smoke labeled openings, provide smoke listed perimeter gasketing assemblies complying with NFPA 105 listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction for smoke control ratings indicated based on testing according to UL 1784.

E. Fire Listed Gasketing: Assemblies complying with NFPA 80 that are listed by a testing and inspecting agency acceptable to authorities having jurisdiction for fire ratings indicated based on testing according to UL-10C.

1. Where frame-applied intumescent seals are required by the manufacturer, provide gaskets that comply with UL10C Standard for Positive Pressure Fire Tests of Door Assemblies and UBC 7-2, Fire Tests of Door Assemblies.

F. Sound-Rated Gasketing: Provide acoustic gasketing to meet Sound Transmission Class (STC) rating required.

G. Meeting-Stile Gasketing: Provide meeting-stile gasketing that fastens to the meeting stiles forming a continuous seal when doors are closed.

H. Door Sweeps or Shoes: Apply to the bottom of the door to close the gap between the door bottom and finished floor or saddle threshold.

1. Provide solid neoprene, EPDM, silicone, or nylon brush type of seal as specified in hardware sets. Vinyl inserts are not allowed except where specified in hardware sets.

I. Automatic Door Bottoms:

1. Provide closed cell sponge, bulb neoprene. or EPDM type of seal as specified in hardware sets.

DOOR HARDWARE 087100-16

2. Door bottom to be mortised, semi mortised, or surface mount as with a minimum thickness as specified in hardware sets.

J. Rain Drips:

1. Provide overhead rain drips for out-swinging hollow metal doors that are not covered against 45 degree blowing rain. Aluminum extrusion to be a minimum of .088 inches thick and extend 2.50 inches from the face of the frame, in anodized finish to match door.

2. Door sweeps or shoes with integral rain drip must meet ADA requirements

K. Thresholds: Provide threshold units not less than 4 inches wide, formed to accommodate change in floor elevation where indicated, and fabricated to accommodate door hardware and fit door frames.

1. Threshold extrusion to be a minimum thickness as specified in hardware sets.

2.17 FINISHES as listed in hardware sets.

PART 3 - EXECUTION

3.01 EXAMINATION

A. Prior to installation of hardware, examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance. Verify doors, frames, and walls have been properly reinforced for hardware installation.

B. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation.

C. Submit a list of deficiencies in writing and proceed with installation only after unsatisfactory conditions have been corrected.

3.02 INSTALLATION

A. Mount door hardware units at heights to comply with the following, unless otherwise indicated or required to comply with governing regulations.

1. Standard Steel Doors and Frames: ANSI/SDI A250.8.

2. Custom Steel Doors and Frames: HMMA 831.

3. Interior Architectural Wood Flush Doors: ANSI/WDMA I.S. 1A

4. Installation Guide for Doors and Hardware: DHI TDH-007-20

B. Install door hardware in accordance with NFPA 80, NFPA 101 and provide post-install inspection, testing as specified in section 1.03.E unless otherwise required to comply with governing regulations.

C. Install each hardware item in compliance with manufacturer's instructions and recommendations, using only fasteners provided by manufacturer.

DOOR HARDWARE 087100-17

D. Do not install surface mounted items until finishes have been completed on substrate. Protect all installed hardware during painting.

E. Set units level, plumb and true to line and location. Adjust and reinforce attachment substrate as necessary for proper installation and operation.

F. Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners and anchors according to industry standards.

G. Install operating parts so they move freely and smoothly without binding, sticking, or excessive clearance.

H. Hinges: Install types and in quantities indicated in door hardware schedule but not fewer than quantity recommended by manufacturer for application indicated.

I. Lock Cylinders:

1. Install construction cores to secure building and areas during construction period.

2. Replace construction cores with permanent cores as indicated in keying section.

3. Furnish permanent cores to Owner for installation.

J. Wiring: Coordinate with Division 26, ELECTRICAL and Division 28 ELECTRONIC SAFETY AND SECURITY sections for:

1. Conduit, junction boxes and wire pulls.

2. Connections to and from power supplies to electrified hardware.

3. Connections to fire/smoke alarm system and smoke evacuation system.

4. Connection of wire to door position switches and wire runs to central room or area, as directed by Architect.

5. Connections to panel interface modules, controllers, and gateways.

6. Testing and labeling wires with Architect's opening number.

K. Key Control System: Tag keys and place them on markers and hooks in key control system cabinet, as determined by final keying schedule.

L. Continuous Hinges: Re-locate the door and frame fire rating labels where they will remain visible so that the hinge does not cover the label once installed.

M. Door Closers & Auto Operators: Mount closers/operators on room side of corridor doors, inside of exterior doors, and stair side of stairway doors from corridors. Mount closers/operators so they are not visible in corridors, lobbies and other public spaces unless approved by Architect.

N. Overhead Stops/Holders: Mount overhead stops/holders on room side of corridor doors, inside of exterior doors, and stair side of stairway doors.

O. Thresholds:

1. Set thresholds in full bed of sealant complying with requirements specified in Division 07 Section ''Joint Sealants.''

2. Aluminum thresholds to be cut-in, and scribed around mullions, frame members, and stops. Do not butt to thresholds. Provide a continuous surface across full width of opening from jamb to jamb.

DOOR HARDWARE 087100-18

3. Where aluminum panic-type (rabbeted) thresholds with neoprene inserts are specified, undercut doors as required to properly mate with seal in threshold.

P. Stops: Provide floor stops for doors unless wall or other type stops are indicated in door hardware schedule. Do not mount floor stops where they may impede traffic or present tripping hazard.

Q. Perimeter Gasketing:

1. Apply to head and jamb, forming seal between door and frame.

2. Install gasketing in a manner eliminating need to cut any seal to install surface mounted hardware. Install compatible mounting bracket for surface mounted hardware unless minimum 1/4 inch thick solid aluminum seals are provided for mounting of surface applied hardware.

R. Meeting Stile Gasketing: Fasten to meeting stiles, forming seal when doors are closed.

S. Door Bottoms and Sweeps: Apply to bottom of door, forming seal with threshold when door is closed.

3.03 ADJUSTING

A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.

1. Spring Hinges: Adjust to achieve positive latching when door can close freely from an open position of 30 degrees.

2. Electric Strikes: Adjust horizontal and vertical alignment of keeper to properly engage lock bolt.

3. Door Closers: Adjust sweep period to comply with accessibility requirements and requirements of authorities having jurisdiction.

B. Occupancy Adjustment: Approximately three to six months after date of Substantial Completion, examine and readjust each item of door hardware, including adjusting operating forces, as necessary to ensure function of doors and door hardware.

3.04 CLEANING AND PROTECTION

A. Clean adjacent surfaces soiled by door hardware installation.

B. Clean operating items per manufacturer's instructions to restore proper function and finish.

C. Provide final protection and maintain conditions that ensure door hardware is without damage or deterioration at time of Substantial Completion.

3.05 DOOR HARDWARE SCHEDULE

DOOR HARDWARE 087100-19

A. The intent of the hardware specification is to specify the hardware for interior and exterior doors, and to establish a type, continuity, and standard of quality. However, it is the door hardware supplier's responsibility to thoroughly review existing conditions, schedules, specifications, drawings, and other Contract Documents to verify the suitability of the hardware specified.

B. Discrepancies, conflicting hardware, and missing items are to be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application.

C. Hardware items are referenced in the following hardware schedule. Refer to the above specifications for special features, options, cylinders/keying, and other requirements.

D. Hardware Sets:

157875 OPT0504718 Version 1

Hardware Group No. 01

Provide each PR door(s) with the following:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

2 EA CONT. HINGE 224XY 628 IVE

2 EA DUMMY PUSH BAR 330 626 VON

2 EA TRIM 550-DT 626 VON

2 EA OH STOP 100S 630 GLY

2 EA SURFACE CLOSER 4040XP EDA TBSRT 689 LCN

1 SET GASKETING 429AA-S AA ZER

2 EA DOOR SWEEP 8192AA AA ZER

2 EA MEETING STILE 8192AA AA ZER

1 EA THRESHOLD 655A-223 A ZER

DOOR HARDWARE 087100-20

Hardware Group No. 02

Provide each PR door(s) with the following:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

2 EA CONT. HINGE 224XY 628 IVE

1 EA REMOVABLE MULLION KR4954 STAB 689 VON

1 EA PANIC HARDWARE CD-99-EO 626 VON

1 EA PANIC HARDWARE CD-99-NL-OP-110MD 626 VON

2 EA TRIM 550-DT 626 VON

1 EA RIM CYLINDER 20-057 ICX 626 SCH

3 EA MORTISE CYLINDER 20-061 ICX (CAM AND COLLAR AS

REQUIRED)

626 SCH

4 EA PRIMUS CORE 20-740-XP 626 SCH

2 EA SURFACE CLOSER 4040XP SCUSH 689 LCN

1 EA RAIN DRIP 142AA AA ZER

1 SET GASKETING 429AA-S AA ZER

2 EA DOOR SWEEP 8198AA AA ZER

1 EA THRESHOLD 65A-223 A ZER

Hardware Group No. 03

Provide each SGL door(s) with the following:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

1 EA CONT. HINGE 224XY 628 IVE

1 EA PRIVACY LOCK W/

OUTSIDE INDICATOR W/

INSIDE INDICATOR

L9040 17N L583-363 OS-OCC IS-

LOC BAA

626 SCH

1 EA SURFACE CLOSER 4040XP REG OR PA AS REQ 689 LCN

1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE

1 EA MOP PLATE 8400 4" X 1" LDW B-CS 630 IVE

1 EA WALL STOP WS406/407CCV 630 IVE

1 EA GASKETING 488SBK PSA BK ZER

DOOR HARDWARE 087100-21

Hardware Group No. 04

Provide each PR door(s) with the following:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

2 EA CONT. HINGE 224XY 628 IVE

2 EA MANUAL FLUSH BOLT FB458 626 IVE

1 EA CYL X TURN DEAD LOCK L460T L583-363 626 SCH

1 EA PRIMUS CORE 20-740-XP 626 SCH

2 EA PUSH PLATE 8200 4" X 16" 630 IVE

2 EA PULL PLATE 8303 10" 4" X 16" 630 IVE

2 EA SURFACE CLOSER 4040XP EDA TBSRT 689 LCN

2 EA ARMOR PLATE 8400 34" X 1" LDW B-CS 630 IVE

2 EA MOP PLATE 8400 4" X 1" LDW B-CS 630 IVE

2 EA WALL STOP/HOLDER WS45 626 IVE

1 EA GASKETING 488SBK PSA BK ZER

1 EA ASTRAGAL Z TYPE ASTRAGAL BY HM DR

SUPPLIER

B/O

Hardware Group No. 05

QTY DESCRIPTION CATALOG NUMBER FINISH MFR

1 EA CONT. HINGE 224XY 628 IVE

1 EA CLASSROOM LOCK…