Addendum 1.pdf

PDF 190 KB Posted

Attached to
Invitation to Negotiate for Leased Space
Solicitation number
ITN-16259
Issued by
Hillsborough County, Florida

About this file

This Addendum 1 document modifies the Invitation to Negotiate for Leased Space issued by the Florida Department of Financial Services for office and warehouse space in Fort Myers to house the Division of Criminal Investigations and State Fire Marshal. Addendum 1, posted on June 26, 2026, increases the required space from between 9,681 and 10,674 usable square feet to between 14,188 and 15,682 usable square feet of contiguous space. The space must accommodate specialized areas including three enclosed offices at 225 square feet, twenty enclosed offices at 150 square feet, seven enclosed offices at 100 square feet, a LAN room, storage and file rooms, pantry and breakroom, copy room, conference room, open team work areas, reception and waiting areas, interview rooms, two secured evidence rooms at 400 square feet each, two secured equipment rooms at 400 square feet each, records storage, supply room, training center at 750 square feet, locker room with shower facilities for decontamination, laundry facility with washer and dryer hookups, IT storage/receiving/workroom, and critically, two open bay warehouse areas (modified from two to one area at 5,000 square feet). Complete written replies are due by August 20, 2026 at 1:00 p.m. ET, with evaluation anticipated August 20 through September 3, 2026, negotiations September 3 through September 30, and Notice of Intent to Award anticipated October 6, 2026.

All space must be measured in usable square feet in accordance with Florida Administrative Code 60H-2.003 and be delivered in turn-key condition with ADA compliance prior to occupancy. The lease structure must be full-service on a gross basis with all operating expenses included in the rental rate and no additional pass-through expenses permitted. Offerors must propose either a seven-year base term with two seven-year renewal options or a ten-year base term with two seven-year renewal options, with annual rental rates per square foot provided for each year. The anticipated lease commencement date is April 1, 2028, and liquidated damages of $492.39 per day apply if the space is not available by that date. Offerors must demonstrate clear title or control through deed, lease agreement, power of attorney, or purchase option documentation and are responsible for all construction costs, permits, inspections, and professional cleaning services. The Agency has authorized Savills, Inc. as its exclusive representative, with inquiries directed to Michael Messina or Chris Brown. Protests must be filed within 72 hours of posting in accordance with Florida Statutes and Administrative Code.

View the file

Other files

File Type Posted
ITN for Leased Space 430.0233-Fort Myers.pdf PDF
Addendum 2.pdf PDF
Addendum 3.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ITN for Leased Space #430:0233 – Fort Myers Addendum 1

Florida Department of Financial Services

ITN 430:0233 – Fort Myers

Any protest concerning this solicitation shall be made in accordance with Sections 120.57(3) and 255.25(3)(d) of the Florida Statutes and Rule 28-110 of the Florida Administrative Code. It is the Agency’s intent to ensure that specifications are written to obtain the best value for the State and that specifications are written to ensure competitiveness and fairness in the solicitation process.

NOTICE OF PROTEST OF THE SOLICITATION DOCUMENTS SHALL BE MADE WITHIN SEVENTY-TWO

HOURS AFTER POSTING OF THE SOLICITATION. Questions to the Official Contact Person shall not constitute formal notice. Failure to file a protest within the time prescribed in Section 120.57(3), Florida Statutes, or failure to file a bond or other security within the time allowed for filing a bond shall constitute a waiver of proceedings under Chapter 120, Florida Statutes.

-REMAINDER OF PAGE INTENTIONALLY LEFT BLANK

Modifications Insertions to the ITN are indicated by an underscore, deletions are indicated by a strikethrough.

1. Section IV, Lease Terms and Conditions, of the ITN is hereby modified as follows:

IV. LEASE TERMS AND CONDITIONS

Responses to all the “Terms and Conditions” should be clearly delineated and specific to Article IV questions, terms, and requirements. Where appropriate, use an “X” to indicate Yes or No.

Certification Regarding Article IV, Lease Terms and Conditions to this ITN. I hereby certify that if the Proposed Space is selected by the Agency, I acknowledge and agree to abide to all requirements and conditions contained therein.

1. Description and Measurement of Proposed Space

The Agency is seeking between 9,681 14,188 and 10,674 15,682 usable square feet of contiguous space.

Type of space required is Office and Warehouse. Space use is for Department of Financial Services’ Division of Criminal Investigations and State Fire Marshal

All references to square feet of the Proposed Space contained in the Reply must be “usable square feet” in accordance with the Department of Management Services Standard Method for Measuring Floor Area in Office Buildings (Florida Administrative Code 60H-2.003). The Agency and DMS reserve the right to independently verify the space measurement.

ADA Requirements - Space must be renovated prior to Lessee’s occupancy, to conform with the requirements of the Americans with Disabilities Accessibility Implementation Act, Section 553.501 ‐ 553.514, Florida Statutes.

The Offeror/Lessor shall be responsible for build-out and clean up and shall provide the Agency with a clean and ready to operate space.

Offeror agrees to deliver an ADA compliant space and has listed the complete address and the proposed usable square feet (as defined in above) on the Submittal Cover Page:

Yes No

2. Attachment A, Agency Specifications, is hereby modified as follows:

ATTACHMENT A

AGENCY SPECIFICATIONS

Please see below for the Agency’s general specifications. During the evaluation and test fit period, the Agency will evaluate on a case-by-case basis whether any of these space requirements will be adjusted based on reviewing the conditions of the Proposed Space. Space typically must be designed to accommodate the approximate number and proposed sizes of workspaces listed below:

Quantity Type of space & size needed Standard

SF SF Voice Data Total Voice

Total Data Personnel and Standard Support Areas

A. 3 Enclosed Office(s) @ 225 SF each 225 675 1 1 6 6 B. 20 Enclosed Office(s) @ 150 SF each 150 3,000 1 1 4 4 C. 7 Enclosed Office(s) @ 100 SF each 100 700 1 1 22 22 D. 1 LAN Room @ 75 SF 75 75 2 2 2 2 E. 2 Storage/File Room @ 100 SF each 100 200 1 1 3 3 F. 1 Pantry/Breakroom @ 200 SF 200 200 1 1 1 1 G. 1 Copy Room @ 150 SF 150 150 1 1 1 1 H. 1 Conference Room for 10-12 people @ 350 SF 350 350 2 2 2 2

I. 1 Open Team Work Area 500 500 1 1 1 1

K. 2 Workstation (s) @ 80 SF each 80 160

Sub Total – Personnel & Standard Support Areas

Circulation space (35%) for items A through J

Total Usable Personnel & Standard Support Area Required:

Public Space Use

L. 1 Main Reception Area 200 200 1 1 1 1

M. 1 Service Counter/Waiting Area 150 150 1 1 1 1

N. 2 Interview Rooms @ 150 SF each 150 300 1 1 2 2

1 Waiting Room 200 200

Special Use Areas

O. 2 Evidence Room (Secured) @ 400 SF 400 800 1 1 2 2 P. 2 Equipment Room (Secured) @ 400 SF 400 800 1 1 2 2 Q. 1 Records Storage (Secured) @ 225 SF 225 225 1 1 2 2 R. 1 Supply Room (Secured) @ 100 SF 100 100 1 1 1 1 S. 1 Training Center @ 750 SF 750 750 2 2 2 2 T. 1 Locker Room / Shower for Decontamination 100 100 U. 1 Laundry Facility w/ Washer and Dryer Hookups 100 100 V. 1 IT Storage/Receiving/Workroom @ 200 SF 200 200 W. 2 1 Open Bay Warehouse @ 5,000 SF 5,000 105,000 2 1 2 1 4 2 4 2

X. Secured Parking (10-15 secured parking spaces) *Voice and data needed for installation of cameras/ - -emergency phone line

Y. WIFI – Wireless Access Points (6) / IP Cameras (4)

Sub Total – Special Support Areas

Circulation space (30%) for items K through WW

Total Usable Special Support Area Required:

Grand Total – Usable Area Required:

File details come from the government source that posted it. Updated .