A00001 Attachment 2-RFC-001 Work Item 78 SW Control Valves Controllers OH.pdf
PDF 841 KB Posted
- Attached to
- FY2021 Dry-Dock Repairs for USCGC SEQUIOA
- Solicitation number
- 70Z085-21-Q-P4504700
About this file
This request for quotation solicits commercial ship repair services for the USCGC SEQUOIA. The Coast Guard requires dry-dock repairs including overhauling two seawater control valves and controllers. The performance period is 23 February through 1 May 2021 at the contractor's dry-dock facility. Quotations are due by 9:00 AM PST on 23 December 2020 and shall include completed attachments with pricing for each contract line item, past performance documentation, certifications, and representations. Award will be a firm-fixed price contract set aside for small businesses with a NAICS code of 336611 and size standard of 1,250 employees.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 4
REQUEST FOR CLARIFICATION
SUBMIT REQUESTS NO LATER THAN: TUESDAY, FEB 26, 2018 @ 012:00 PM NOON PST
CUTTER & HULL NUMBER: USCGC SEQUOIA WLB-215
USCG RFQ Number: 70Z085-21-Q-P4504700
QUESTION NO: 1 OF 1
OFFEROR’S NAME: JAG Alaska, Inc.
SUBMITTAL DATE: 12.02.20
SOLICITATION SECTION NO
AND/OR PAGE NO:
D-078 PARAGRAPH NO: 1.1,1.2, 4.0
DEFINITE/OPTION ITEM NO: Definitive PARAGRAPH NO:
TITLE (DESCRIPTION):
Seawater Control Valves and Controllers, Overhaul
QUESTION:
In 1.1 Intent: “Contractor is to overhaul two Leslie Valves. One automated temperature control 8”, air operated 3-way rotary valves for sea bay.
The second is pressure control valve for ASW system (4” Class DDL-3X)”.
1.2 list ASW Pressure regulating valve (4”0 class DDL -3X) however, under GFP a 6” RVP 3-way control valve is listed
In 4.0 NOTES we have a 6” valve listed and a 4” 3X.
The spec is not clear as to what the sizes and types of valves are to be overhauled or renewed. Also, the
OEM stated that any time an “X” follows a number it designates a special designation for something in the manufacturing of the particular valve. Without the serial number from the specific valve the factory cannot identify the valve.
Please provide serial number from each valve to be overhauled/renewed to clarify what the government is requesting.
4.0 Notes
USCG Answer. Thank you for your question, you have identified an inadvertent error in 1.1. scope, the temperature control valve is 6” (as cited elsewhere in specification) and not 8”. USCG currently does not have the serial numbers of the two valves, identifying them on an operating Cutter is impractical at this stage. USCG has successfully exercised this baseline Leslie Valve specification without serial numbers in past. The 4” Pressure control valve has a NSN/NIIN of 01-533-6679 (GFP in spec contingency in the event the valves was discovered to be unrepairable). Since Leslie themselves supplies USCG this valve they should have all the identifying criteria. In the interest of timely submittal of bids, Contractor shall bid on a generic bid of valves as described. In the event upon contract award when the exact valve is in hand at the factory, any cost differences in the repair between the generic valve and the delivered valves subject to overhaul shall be documented by submittal of a CFR noting the specific cost differences. The CFR would then be subject to contract negotiations, only on subcontractor additional repair cost based on documentation presented.
File details come from the government source that posted it. Updated .