P1451546584-9913-PID000A.pdf

PDF 331 KB Posted

Attached to
DAUNTLESS DOCKSIDE REPAIRS FY19
Solicitation number
70Z080-19-Q-P4571000
Issued by

About this file

DAUNTLESS DRAWING/REFERENCE - SEE FILE NAME

View the file

Other files

Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

M

09-7-003 1/2''

09-7-004 1/2''

10-7-001 1''

G 1/2'' 10-7-005

Subject to technical modifications

09-7-002 3/4''

09-8-001 3/4''

10-7-007 1/4''

13-7-002 1/2''

PAL/PAH

11-9-001

PI

12-7-001 G1/2''

1/2'' 10-7-006

1/4'' 08-7-004

1 1/4'' / RP 1/4''

10-3-001

10-7-002 G1''

10-9-003

PDSH

09-7-008 G1/4''

92-7-003 G 3/4''

1/4'' 08-7-006

08-7-005 1/4''

09-7-006 1/4''

3/4''/1/4''

13-7-001 1/2''

11-5-001 1/2"

1/4''/1/2''

1/2''/1/4'' 09-7-011 G1/4''

1/ 2' 1/

4'

1/ 4' 1/

2'

09-7-010 1/4''

11-7-003 G1/4''

1/4''/1/2''

11-7-001 1/2''

95-7-001 1/2''

1/2'' 11-7-005

11-7-006 1/4''

1/4'' 08-7-007

10-9-001

PI

10-9-002

PI

06-7-001

DN25

10-9-006

TE

TAL

TAH

09-7-005 G1/2''

09-8-002

13-9-001

PI

10-9-007

TE

10-9-008

IAL

93.2

1/8'' / 1/4'' 08-7-002

92-7-001 1/2''

1/2'' FNPT / 1/2''BSP / 1/4'' FNPT

92-3-001

90-9-001

LSHH

LAHH

92-7-002 1/2''

93.1

1/ 4' 1/

2' m m

11-9-005

OSH

11 95

10-8-001 13-8-001 Sl op e

11-8-001

10-7-003 1/4''

10-7-004 1/4''

INLET09 EN 102423/4'' PN25

INLET10 DIN1'' PN64

OUTLET11 DIN1/2'' PN64

INLET06 DN25 PN16

OUTLET STU91 ---DN50 ---

OUTLET STU92 EN 102421/2'' PN16

DRAIN93.1 EN 102421/2'' PN25

DRAIN STU93.2 EN 102421/2'' PN25

RETURN TO BILGE TANK95 DIN1/2'' PN64BILGE WATER

LEAK OIL

SLUDGE

SLUDGE TANK AIR VENT

HOTWATER

HOTWATER

BILGE WATER

LIGHT PHASE

CLEAN WATER

BILGE WATER

WATER

F4

F1

F2

F3

SMALL SLUDGE TANK

VOLUME APPROX.

0,06m³

OUTLET13 DIN1/2'' PN64

1/2'' 11-7-002

WSE 5-01-037

10-1-001 10-1-001/M1

M

50 20

HOTWATER

HOTWATER

COMPRESSED AIR

WATER

BILGE WATER FEED

CLEAN WATER OUTLET

BILGE WATER RETURN

OUTLET OF LIGHT PHASE

SLUDGE DISCHARGE

LEAKOIL DRAIN

BILGE WATER

MEDIUMNO.

POS. DESCRIPTION

CONNECTIONTABLE

INLET08 DIN 23531/4'' PN25

10-9-009

SC

12-7-002 1/2''

10-5-001

09-7-001

1/4''/1/2''

09-9-001

PI

DN20

09-7-013

TE

11-7-009 G1/4''

11-7-008 1/2''

DN25/DN32

DN32/DN25

1/ 2' 1/

4'

1/

4' 5/

07-7-001

DN25

2F 1F

3F 4F

3F

4F

2F

1F to B ilg e

1/4'' 08-7-013

PI

1/4''

PCV

08-7-001

M

L

K

I

H

G

F

E

D

C

B

M

L

K

I

H

G

F

E

D

C

B

AA

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

CAD-Drawingon this drawing We reserve all rights

Description of Revision

Location is electronically stored

Approved

Checked

Created

Revision proof

Date Name

Revision

Client

Copyright reserved

Description

Last modified by

Rev.-Date

Country

Last modified on

Drawing-No.

Scale Size

Rev.-Name

Sheet / Sheets

D-59302 Oelde

GEA Westfalia Separator

WMEC-901 - 913

2211Ka

19.10.2015

06.10.2015

2321CE

US Coast Guard

P&ID

BM_E500 cleandesign

WSE5-01-037

MA_1_546584

2321CE

USA

27.10.2015

C E

SV42080OEL0038\Order Processing - OP\Kundenauftraege\BL_MARINE\USA\US Coast Gurad\Proj. 30033289 - Kom. 1451546584\MA_1_546584.prj@SV42080OEL0038\Projekt/Dokumentablage\Basic and Process Engineering\Zeichnungen\P1451546584-9913-PID000A pr in te d on .1 0.

fo r

P1451546584-9913-PID000A

A001 01

11-9-011

ZS

09-7-014 1/4''

11-7-010 1/4''

D N

D N

OUTLET07 DN25 DIN 2633

Ablauf12 DIN1/2'' PN64

1''/1/2''

1' 1/

2' '1' 1/

2'

3/ 4' 1/

4'

1" 10-4-001

1''/1/2''

1/ 2' 1/

4'

1/2''/1''

3/ 4' 1'

In case of excessive contamination of the product, (particle size >3 mm, fiber length >42 mm) it is recommended to install a basket type pre-strainer with an absolute filter rate of 3 mm.

11-9-002

PT

10-9-018

SIS

LEAK OIL

Preheater Unit Volume 13m³

Assembly: highest place loose supply

Assembly example for customer all dashed lines have to be installed by customer max. Volume complete

Vordruck am Gasventil 1 bar loose supply

Assembly:

loose supply the lowest pointsetting pre-pressure 1 bar

25-30 l

3/4'' 06-7-003

DN40

06-3-001 M

06-7-004

DN40

06-9-001

TC

06-5-001

06-9-002

TAHH

06-9-003

PI

06-9-004

PI

06-9-005

TI

06-9-006

TI

06-7-006 1/2''

06-7-005 1/2''

06-9-008

PI

06-2-001

Sample point

Connection point for presentation of OMD- monitor

Next outlet also the advice to transfer this to sludge or dirty oil tank Next to outlet also overboard valve

Pumping device for test 15ppm alarm

Ø1 mm

COMPRESSED AIR

The counter pressure** must beadjusted with valve 11-7-005

Insulation: Thickness 12mm Material: Mineral woolmatting, Aluminium luminated, WSN76-0210-00

Heater for Pos.: 10-5-001 Position of heater connections

All pipes shown by dashed lines have to be installed by yard

Installation instructions No.: 2058-9601-020 have to be observed

For symbols refer to: DIN 28004, DIN 2429; DIN 2481, DIN 30600

Do not discharge the oily sludge into the public sewage system!

with GEA in advance.

If other materials shall be used, this must be clarified

11-7-020 G1/2''

2321CE19.10.2015A ISSUED FOR INSTALLATION

Model
Layout1