cae-1700951-e002 signed.pdf

PDF 409 KB Posted

Attached to
West Columbia, SC CAE RCAG Tower Replacement Federal contract opportunity
Solicitation number
6973GH-21-R-00072
Issued by
Department of Transportation Federal Aviation Administration Franchise Acquisition Services

About this file

This solicitation is seeking proposals for the demolition of four existing 50-foot guyed antenna towers and construction of four new 60-foot free-standing antenna towers at the Columbia Metropolitan Airport in West Columbia, South Carolina. Contractors must furnish all necessary materials, equipment, labor, insurance, permits and supervision to complete the work in accordance with the specifications, drawings and other attachments. A firm-fixed price construction contract will be awarded. Proposals are due no later than May 14, 2021. All questions must be submitted in writing by May 7, 2021. Contractors must be registered in the System for Award Management to be eligible for award. The Federal Aviation Administration will administer the contract in accordance with the Acquisition Management System in place of the Federal Acquisition Regulation.

View the file

Other files for this federal contract opportunity

Other files attached to West Columbia, SC CAE RCAG Tower Replacement, newest first.
File Type Posted
6973GH-21-R-00072 Amendment 0004.pdf PDF
cae-1700951-c004 signed.pdf PDF
cae-1700951-c003 signed.pdf PDF
cae-1700951-s001 signed.pdf PDF
cae-1700951-g001 signed.pdf PDF
cae-1700951-e001 signed.pdf PDF
cae-1700951-e007 signed.pdf PDF
Columbia Amendment 00003 - Revised Drawings.pdf PDF
Amendment 00002-extension.pdf PDF
Amendment 00001-revised specs and extension.pdf PDF
13 10 00 Antenna Towers Revision A.pdf PDF
SOW Tower Replacement CAE RCAG Columbia SC.doc DOC document
COVID Special Contract Requirement.pdf PDF
Contractor Release Form DOT F 4220.4.pdf PDF
Drawings to Replace (4) 50ft Guyed Towers with (4) 60ft Free Standing Towers.pdf PDF
Performance Bond.pdf PDF
Wage Determination SC20210028.pdf PDF
6973GH-21-R-00072.pdf PDF
Specifications CAE RCAG Tower Replacement Columbia SC.pdf PDF
Experience Information Form.pdf PDF
Payment Bonds.doc DOC document
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

c a e -1

-e

.d g n

/1

/2

:4

:3

A

M O c ta w n C a rt e r

A

B

C

D

E

F

G

H

8 7 6 5 4 3 2 1

H

G

F

E

D

C

12345678

REVDRAWING NO

DATE JCN

APPROVED BY

ISSUED BY

CHECKED

DRAWN

DESIGNED

SUBMITTED BY

REVIEWED BY

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

REV

DATE

APPROVED

DESCRIPTION JCN

DATE

REDLINE

APVD

A

INSIDE JUNCTION BOX

LEAVE 3' COILED

4/0 BARE IN 1-1/4" PVC

(TYP)

LADDER RUNG

TO TOWER

LADDER ATTACHED

FOUNDATION

TOWER

LEGEND

4/0

6 4 5

TOWER WITH BEAM CLAMPS

1 5/8"x 1 5/8" ATTACH TO

STAINLESS STEEL STRUT

CORNERS

TYPICAL OPPOSITE

TO COUNTERPOISE

2 22

J-BOX

CONDUIT, PVC 4"

CONDUIT, PVC 1-1/4"

A

E002

28R EVERY 3 FT)

CABLE CLAMP, THOMPSON #142 OR EQUAL (SUPPORT THOMPSON

NOTES

4/0 AWG BARE COPPER, 28 STRANDS, WT 660 LBS/1000 FT

PIPE CLAMP, THOMPSON #240X OR EQUAL

PARALLEL CLAMP, THOMPSON #4248 OR EQUAL

GROUND ROD, COPPER CLAD 3/4" DIA x 10'

STANDARD STEEL PIPE, GALV 2"x 21 FEET LONG (WATER PIPE)

AIR TERMINAL, 5/8"x 3', THOMPSON #667 OR EQUAL

VERTICAL CONNECTOR, THOMPSON #690 OR EQUAL10

U-BOLT, 2" WITH SELF LOCKING NUTS, SS

28 STRANDS,

WT 375 LBS/1000'. THOMPSON 28R OR EQUAL DOWN CONDUCTOR,

M A

X

OR EQUAL

THOMPSON NO 690

ELECT CONNECTOR

GALV WATER PIPE

2"x 21'

SEE DRAWING E003

COUNTERPOISE

TIE TO BUILDING

SEE DRAWING E003

COUNTERPOISE

TIE TO BUILDING

SEE NOTE 7

G R

A T

IN

G

H A

T C

H A

C C

E S

S

L A

D D

E R

5 6

THE J-BOX

COILED INSIDE

3'THOMPSON 28R

LEAVE 2 EACH

NOT TO SCALEE002

PLATFORM PLAN VIEW 4

NOT TO SCALEE002

TOWER CONDUIT SECTION 5

NOT TO SCALEE002

AIR TEMINAL ASSEMBLY

NOT TO SCALEE002

TOP OF TOWER JUNCTION BOX ELEVATION 2

NOT TO SCALEE002

TOWER CONDUIT ELEVATION

A

NOT TO SCALEE002

LADDER GROUNDING SECTION

TOWER LEGS

ON OPPOSITE

EACH INSTALLED

(TYP OF 2)

SEE NOTE 8

OF LADDER

4/0 TO BACK

JUNCTION BOX

GROUNDING INTO

CONDUIT FOR

PURPOSES.

INSTALL 4-4 IN PVC CONDUITS, NUMBER OF CONDUITS SHOWN HERE ARE FOR ILUSTRATION 9.

HAZARD.

4/0 AWG EXOTHERMICALLY BOND TO BACK OF LADDER NEAR ITS BASE TO AVOID TRIPPING 8.

THOMPSON 28R CADWELDED TO TOWER FRAME.7.

AND BURIED 2 FT DEEP.

ALL COUNTERPOISE SHALL BE PLACED 2 TO 6 FT AWAY FROM CONCRETE FOUNDATIONS 6.

SECURE DOWN CONDUCTOR T0 4/0, A MINIMUM OF 6" BELOW THE EXOTHERMIC WELD.

EACH,(TYPICALLY OPPOSING LEGS). USE PARALELL CLAMP THOMPSON #4248 OR EQUAL TO

EXOTHERMIC WELD 4/0 AWG TO TOWER LEG A MINIMUM OF 18" ABOVE FOUNDATION, 2 5.

INSTALL LADDER ON OPPOSITE SIDE OF JUNCTION BOX.4.

ALL GROUNDING CONNECTIONS BELOW GRADE BY EXOTHERMIC WELD.3.

THAN 12".

INSTALL DOWN CONDUCTOR WITH A MINIMUM OF BENDS AND NO SHARP BENDS OF LESS 2.

APPROVED EQUAL. CONDUCTOR SHALL REMAIN TIGHT BETWEEN CLAMPS

OF THE PLATFORM, AND DOWN THE TOWER LEG WITH THOMPSON CABLE CLAMP #142 OR

SUPPORT THE DOWN CONDUCTOR AT A MINIMUM OF 3'-0" SPACING AROUND THE PERIMETER 1.

WELD

EXOTHERMIC

TOWER LEGS

ON OPPOSITE

EACH INSTALLED

(TYP OF 2)

SEE NOTE 5

TO COUNTERPOISE

SEE NOTE 9

STRUCTURE (TYP)

CADWELD TO

FIBERGLASS J-BOX

36"x 30"x 10"

SS UNISTRUT FRAME

CAP

PIPE

SEE NOTE 4

JUNCTION BOX,

SEE NOTE 9

E D

M

IS

S

U E

D F

O R

ENGINEERING SERVICES

COMMUNICATIONS

RCAG

ANTENNA TOWER LIGHTNING PROTECTION

TOWER REPLACEMENT

SCCOLUMBIA METROPOLITAN AIRPORTCOLUMBIA

Stacey L. RainesFrancisco J. Cortes

RC

FC

PROJECT ENGINEER MGR: ENGINEERING - CENTER A

05/29/2020 1700951

CAE-1700951-E002 A

05/07/20211700951CONSTRUCTION (J.CORTES) DS05/07/2021A

c a e -1

-e

.d g n

THIS DRAWING PRODUCED ON ASO REGION MICROSTATION SYSTEM

ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA

C O

N S

T R

U C

T

IO

N

ORIGINAL SIGNED BY: ORIGINAL SIGNED BY:

SEE NOTE 9

BOX ON BUILDING

CONDUIT TO JUNCTION

2021-05-19T08:35:59-0400
Francisco Javier Cortes