cae-1700951-c003 signed.pdf

PDF 235 KB Posted

Attached to
West Columbia, SC CAE RCAG Tower Replacement Federal contract opportunity
Solicitation number
6973GH-21-R-00072
Issued by
Department of Transportation Federal Aviation Administration Franchise Acquisition Services

About this file

This solicitation seeks proposals for the demolition of four existing 50-foot guyed antenna towers and construction of four new 60-foot free-standing antenna towers at the Columbia Metropolitan Airport in West Columbia, South Carolina. Interested offerors must submit proposals by 5:00pm CST on May 14, 2021 to Michelle Abraham, Contract Specialist at the Federal Aviation Administration. The selected contractor will be responsible for furnishing all necessary materials, equipment, labor, permits, insurance, and supervision to complete the tower replacement project according to the specifications, drawings, and statements of work provided. The FAA intends to award a firm-fixed-price construction contract and encourages any questions about the project scope, drawings or process to be submitted in writing by May 7th to allow responses prior to the proposal deadline. Offerors must register with the System for Award Management and maintain active registration through proposal submission to be eligible for award.

View the file

Other files for this federal contract opportunity

Other files attached to West Columbia, SC CAE RCAG Tower Replacement, newest first.
File Type Posted
cae-1700951-e002 signed.pdf PDF
6973GH-21-R-00072 Amendment 0004.pdf PDF
cae-1700951-c004 signed.pdf PDF
cae-1700951-s001 signed.pdf PDF
cae-1700951-g001 signed.pdf PDF
cae-1700951-e001 signed.pdf PDF
cae-1700951-e007 signed.pdf PDF
Columbia Amendment 00003 - Revised Drawings.pdf PDF
Amendment 00002-extension.pdf PDF
Amendment 00001-revised specs and extension.pdf PDF
13 10 00 Antenna Towers Revision A.pdf PDF
SOW Tower Replacement CAE RCAG Columbia SC.doc DOC document
COVID Special Contract Requirement.pdf PDF
Contractor Release Form DOT F 4220.4.pdf PDF
Drawings to Replace (4) 50ft Guyed Towers with (4) 60ft Free Standing Towers.pdf PDF
Performance Bond.pdf PDF
Wage Determination SC20210028.pdf PDF
6973GH-21-R-00072.pdf PDF
Specifications CAE RCAG Tower Replacement Columbia SC.pdf PDF
Experience Information Form.pdf PDF
Payment Bonds.doc DOC document
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

c a e -1

-c

.d g n

/1

/2

:1

:1

A

M O c ta w n C a rt e r

A

B

C

D

E

F

G

H

8 7 6 5 4 3 2 1

H

G

F

E

D

C

12345678

REVDRAWING NO

DATE JCN

APPROVED BY

ISSUED BY

CHECKED

DRAWN

DESIGNED

SUBMITTED BY

REVIEWED BY

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

REV

DATE

APPROVED

DESCRIPTION JCN

DATE

REDLINE

APVD

A

E D

M

IS

S

U E

D F

O R

ENGINEERING SERVICES

COMMUNICATIONS

RCAG

BUILDING FLOOR PLAN

TOWER REPLACEMENT

SCCOLUMBIA METROPOLITAN AIRPORTCOLUMBIA

Stacey L. RainesFrancisco J. Cortes

RC

FC

PROJECT ENGINEER MGR: ENGINEERING - CENTER A

05/29/2020 1700951

CAE-1700951-C003 A

05/07/20211700951CONSTRUCTION (J.CORTES) DS05/07/2021A

c a e -1

-c

.d g n

THIS DRAWING PRODUCED ON ASO REGION MICROSTATION SYSTEM

ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA

C O

N S

T R

U C

T

IO

N

NOTES

N

SEE NOTE 1

JUNCTION BOX

EXISTING

SEE NOTE 1

JUNCTION BOX

EXISTING

SEE NOTE 2

TELCO BOX

EXISTING

BULK PLATE PLATES

GROUND

BOX

JUNCTION BOX

JUNCTION

TELCO BOX TELCO BOX

ER3

MTDS

269.550

ER2

124.700

319.200

ER1

127.875

335.500

ER4

(UNUSED)134.975

278.300(UNUSED)

ER6

122.650

ER5

BULK PLATE

LB

JUNCTION BOX

PLATES

GROUND

AC AC

PROTECTOR

SURGE

ERMS

E/G

SOL. SW.

METER

MDS

HOOD

HOOD

C003 NOT TO SCALE

BUILDING FLOOR PLAN

HOOD

BENCH

WORK

DESK

PANEL A

POWER

PANEL B

POWER

SW

POWER

GENERATOR

ENGINE

32'-0"

ORIGINAL SIGNED BY: ORIGINAL SIGNED BY:

EXISTING EMPTY TELCO BOX TO BE REMOVED.2.

CONDUITS PER BOX. REUSE EXISTING PENETRATIONS INTO BUILDING.

48"x36"x12" JUNCTION BOXES ONE PER TOWER. INSTALL FOUR 4" PVC

REMOVE CABLES. TRIM CONDUITS 12" BELOW GRADE. INSTALL FOUR NEW

REMOVE EXISTING JUNCTION BOXES CONTAINING OLD SPARE HELIAX CABLES. 1.

2021-05-19T08:29:51-0400
Francisco Javier Cortes

File details come from the government source that posted it. Updated .