Data-Sheet-CSM-DS-CSM-E.pdf
PDF 1 MB Posted
- Attached to
- TS FREEDOM STAR FY18 REPAIR PACKAGE
- Solicitation number
- 6933A218Q000020
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Diesel_Oil_Pump_Motor.pdf | ||
| Liferaft_Certificates_2017.pdf | ||
| Jacket_Water_Heaters.docx | DOCX document | |
| Tees_Gill_Parts_List.pdf | ||
| 6933A218Q000020_combined_synp_sol.pdf | ||
| FY_18_TSFS_WD_Pier_Side_Repairs.pdf | ||
| 2017_Annual_Firefighting_Equipment.pdf | ||
| SCBAs_Parts_List.pdf | ||
| Safety_Radio_Parts_List.pdf | ||
| 1427-555,_Rev_-,_TV_FREEDOM_STAR,_FIRE_AND_SAFETY_PLAN.pdf | ||
| Attmt_II_Vendor_Price_Sheet.xls | XLS spreadsheet | |
| Diesel_Oil_Pump.pdf | ||
| Attmt_I_SOW_TSFS_2018_Fall_Items.docx | DOCX document | |
| Mooring_Line_Parts_List.pdf | ||
| Freedom_Star_Imm_Suit_Inv_2018.docx | DOCX document | |
| Tach_Installation_Manual.pdf | ||
| 10-2017_Radio_Survey.pdf |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HOTflow® Heating System
CSM
HOTSTART’s CSM HOTflow® heating system is a coolant preheater, developed to maintain optimal temperatures for diesel and gas engines in stationary land power, marine, construction equipment, and truck applications.
sales@hotstart .com | www.hotstart .com DS-CSM-E 2018-3/rev13
BENEFITS & FEATURES
CONTROLS & AUTOMATIC OPERATION
The CSM's control box allows for easy power connections and enables automatic heater operation, eliminating the need for additional customer-supplied control components.
SINGLE HEATER SOLUTION
The CSM's power and pump-driven forced circulation provides superior heat distribution, making the CSM a viable option to replace paired or multiple convection-based heaters – improving heating performance while reducing maintenance costs.
HEAVY DUTY EFFICIENCY
The CSM features the most powerful pump (10 gpm flow) and most powerful heating element options (up to 12 kW) in the HOTflow lineup. The CSM's heating power in an energy efficient system is ideal for replacing costly convection-based heaters in large-engine installations up to 100 L displacement.
MULTIPLE CONFIGURATIONS
The CSM lineup is equipped to meet a wide array of conditions, including power source requirements and agency certifications. Whatever your power or heating needs, there's a CSM to meet your specific heating system application.
CSM Style A shown with union pump.
CSM Style B shown with flange pump.
GENERATOR HEAVY
EQUIPMENT
TRUCK
& BUS
MARINE
Style A
Height* (HA) Width (WA) Depth (DA) Weight
15.0” 19.4” 9.5” 37 lbs
383 mm 493 mm 242 mm 16.8 kg
Style B
Height* (HB) Width (WB) Depth (DB) Weight
17.0” 19.4” 9.5” 54 lbs
434 mm 493 mm 242 mm 24.5 kg
System
Phase single-phase (1 Ø) three-phase (3 Ø)
Voltage (60 Hz) 120 V 208 V 240 V 440 V 480 V 575 V
Voltage (50 Hz) 230 V 400 V
Control Box Ingress NEMA 4 / IP66
Motor Ingress NEMA 2 (UL-listed) / IP44 (CE-compliant)
Min./Max. Ambient Temp. -4 – 104 °F (-20 – 40 °C)
Certification UL/C-US listed models available (E250789)
CE-compliant models available
Coolant
Fluid Type Water Coolant mix (50% water/50% glycol)
Heat Power 3 kW 6 kW 9 kW 10.5 kW 12 kW
Temp. Control Fixed, 100 – 120 °F (38 – 49 °C)
Pump Power 97 W (60 Hz) / 70 W (50 Hz)
Flow 10 gpm @ 10 ft WC (37.9 L/min @ 3 m WC)
Max. Pressure 125 psi (860 kPa)
Pressure Loss 0.2 psi (1.5 kPa)
Inlet/Outlet 1” NPT
ORDERING INFORMATION
CSM
Engine Displacement
Power Supply Heating System
V Ø Hz kW Amps Style Model Number
1000 – 1500 CID
15 – 25 L
120 1 60 3 26.3 A CSM10301-000
208 1 60 3 15.1 A CSM10308-000
208 3 60 3 8.7 B CSM30308-000
230 1 50 3 13.7 A **CSM1030J-5A0
240 1 60 3 13.1 A CSM10302-000
400 3 50 3 4.9 B **CSM3030A-5A0
480 1 60 3 3.8 B CSM10304-000
480 3 60 3 4.4 B CSM30304-000
1500 – 3000 CID
25 – 50 L
208 1 60 6 29.6 A CSM10608-000
208 3 60 6 17.1 B CSM30608-000
230 1 50 6 26.7 A **CSM1060J-5A0
240 1 60 6 25.6 A CSM10602-000
400 3 50 6 8.9 B **CSM3060A-5A0
440 3 60 6 8.1 B **CSM3060F-5A1
480 1 60 6 12.8 B CSM10604-000
480 3 60 6 7.4 B CSM30604-000
575 3 60 6 6.2 B CSM30605-000
3000 – 4500 CID
50 – 75 L
208 1 60 9 44.0 A CSM10908-000
208 3 60 9 25.4 B CSM30908-000
230 1 50 9 39.8 A **CSM1090J-5A0
240 1 60 9 38.1 A CSM10902-000
400 3 50 9 13.2 B **CSM3090A-5A0
440 3 60 9 12.2 B **CSM3090F-5A1
480 1 60 9 19.1 B CSM10904-000
480 3 60 9 11.0 B CSM30904-000
575 3 60 9 9.2 B CSM30905-000
4500 – 6000 CID
75 – 100 L
208 1 60 10.5 51.2 B CSM11058-000
208 3 60 12 33.7 B CSM31208-000
230 1 50 12 52.8 B **CSM1120J-5A0
240 1 60 12 50.6 B CSM11202-000
400 3 50 12 17.5 B **CSM3120A-5A0
440 3 60 12 15.9 B **CSM3120F-5A2
480 1 60 12 25.3 B CSM11204-000
480 3 60 12 14.6 B CSM31204-000
575 3 60 12 12.2 B CSM31205-000
** – CE-compliant/union pump configuration Other voltages available.
Consult the factory.
* Height values are stated for flange connection pump. If union pump is installed, the model's height will decrease by approximately 1.5” (38 mm).
CSM Style A shown with UL-recognized union pump.
Dimensions may vary.
CSM Style B shown with CE-compliant union pump. Dimensions may vary.
Options shown represent typical tested or certified configurations. Additional options or configurations may be available. For assistance with your heating system application, contact HOTSTART at 509.600.3700 or sales@hotstart.com.
HOTflow® Heating System
CSM
DS-CSM-E
2018-3/rev13sales@hotstart .com | www.hotstart .com
GENERATOR HEAVY
EQUIPMENT
TRUCK
& BUS
MARINE
A
A A
H
W D
B
B B
H
W D
File details come from the government source that posted it.