657-19-117JB - Bid Documents - Part 1.pdf
PDF 8 MB Posted
- Attached to
- Implement Sterile Processing Service Ventilation Requirements PN:657-19-117JB Federal contract opportunity
- Solicitation number
- 36C25520R0082
About this file
This federal contract opportunity notice seeks proposals for a project to implement sterile processing service ventilation requirements at a Veterans Health Administration facility. The project scope includes demolishing existing structures, installing new ventilation systems, and performing related construction work. The cost is estimated between $500,000 to $1,000,000, and the work must be completed within 365 calendar days of the notice to proceed. The North American Industry Classification code is 238220 with a small business size standard of $16.5 million. As a total small business set-aside, at least 25% of the general construction labor must be performed by a service-disabled veteran-owned small business. Proposals are due by June 2020 and award will be made using the best value tradeoff source selection process.
View the file
Other files for this federal contract opportunity
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4 160 VO LTS
D UST CO LLECTO R
LIQ
UEFIED PETRO
LEUM
G
AS
FLAM
M
ABLE G
AS 2
TRASH CO M PACTO R
P S
ILVER
B
UILDING
1 23
B UILDING 23
VA PO LICE
E LECTR IC AC CESS
TRANSFO RM ER
TRANSFO RM ER
TRANSFO RM ER
H VAC UNIT
E LECTRI C PANEL
H VAC UNIT
S&C PAD M O UNTED G EAR
CATALO G # 55152-C3DG IG 2P1V M O DEL# PM H-9E E13299 SG -52
13278
1CC
56G
3T 183
1CC
321G
1CC
5 4
4T
60G
51T
60T
52SG
52G
53G
53T
1CC
104T
102T
101T
1CC 55G
AREA OF WORK
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
657-19-117JB
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM VEG 19.23
100% BID DOCUMENTS
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
/2
/2
:2 :0
A
M
01-GI-001
COVER SHEET
01 35
IMPLEMENT STERILE PROCESSING
SERVICE VENTILATION REQUIREMENTS
MVP SB03/26/2020
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA ST. LOUIS HEALTHCARE SYSTEM
VA PROJECT NUMBER: 657-19-117JB
##-XX-###
DISCIPLINE DESIGNATORS EXAMPLES
GI = GENERAL INFORMATION
GC = GENERAL CONTRACT
CS = CIVIL SITE
AD = ARCHITECTURAL DEMOLITION
AS = ARCHITECTURAL SITE
AE = ARCHITECTURAL ELEMENTS
FLOOR PLANS, ELEVATIONS, DETAILS
AI = ARCHITECTURAL INTERIORS
AG = ARCHITECTURAL GRAPHICS
AF = ARCHITECTURAL FINISHES
AC = ARCHITECTURAL CEILING PLAN
AW = ARCHITECTURAL WAYFINDING
AP = ARCHITECTURAL SPACE PLANNING
FLOOR PLANS & SCHEDULES
AL = ARCHITECTURAL LIFE SAFETY
DRAWINGS
SG = STRUCTURAL GENERAL
SF = STRUCTURAL FRAMING
MG = MECHANICAL GENERAL
MP = MECHANICAL PIPING
MH = MECHANICAL HVAC
PG = PLUMBING MEDICAL GAS
PL = PLUMBING FIXTURES
EG = ELECTRICAL GENERAL
EL = ELECTRICAL LIGHTING
DRAWING INDEX LEGEND
SHEET TYPE DESIGNATORS
0 = GENERAL
1 = PLANS
2 = ELEVATIONS
3 = SECTIONS
4 = LARGE-SCALE VIEWS
5 = DETAILS
6 = SCHEDULES & DIAGRAMS
7 = USER DEFINED
8 = USER DEFINED
9 = 3D REPRESENTATIONS
BUILDING NUMBER
FLOOR NUMBER ON PLAN SHEETS
SHEET NUMBER
JEFFERSON BARRACKS
IMPLEMENT STERILE PROCESSING
SERVICE VENTILATION
REQUIREMENTS
OVERALL CAMPUS SITE PLAN, BUILDING NUMBER, AND PROJECT LOCATOR
Plan North
True North
SHEET LIST
Sheet Number Sheet Name
01-GI-001 COVER SHEET
01-GI-002 GENERAL INFORMATION AND SYMBOLS
01-AD-100 ARCHITECTURAL DEMOLITION PLAN - FLOOR 00
01-AE-100 ARCHITECTURAL FLOOR PLAN - FLOOR 00
01-AE-501 ARCHITECTURAL WALL TYPES AND DETAILS
01-MG-001 MECHANICAL ABBREVIATIONS AND GENERAL NOTES
01-MG-002 MECHANICAL SYMBOLS
01-MG-501 MECHANICAL DETAILS
01-MG-502 MECHANICAL DETAILS
01-MG-503 MECHANICAL DETAILS
01-MG-504 MECHANICAL DETAILS
01-MG-505 MECHANICAL DETAILS
01-MG-506 MECHANICAL DETAILS
01-MG-507 MECHANICAL DETAILS
01-MG-601 MECHANICAL SCHEDULES
01-MG-701 MECHANICAL CONTROLS
01-MG-702 MECHANICAL CONTROLS
01-MD-100 MECHANICAL DEMO HVAC PLAN - FLOOR 00
01-MD-101 MECHANICAL PIPING DEMO PLAN - FLOOR 00
01-MH-100 MECHANICAL HVAC PLAN - FLOOR 00
01-MP-100 MECHANICAL PIPING PLAN - FLOOR 00
01-MP-300 MECHANICAL ROOM SECTIONS
01-MP-301 MECHANICAL ROOM SECTIONS
01-EG-001 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES
01-EG-002 ELECTRICAL SYMBOLS
01-EP-100 ELECTRICAL POWER PLAN - FLOOR 00
01-EI-100 ELECTRICAL INSTRUMENTATION PLAN - FLOOR 00
01-ET-100 ELECTRICAL TELECOMMUNICATIONS PLAN - FLOOR 00
01-EG-601 ONE-LINE DIAGRAM & FEEDER SCHEDULE
01-EG-501 ELECTRICAL DETAILS
01-EG-502 ELECTRICAL DETAILS
01-EG-503 ELECTRICAL DETAILS
01-EG-504 ELECTRICAL SEISMIC DETAILS
01-EG-505 MECHANICAL EQUIPMENT SCHEDULE
01-EG-506 PANEL SCHEDULES
Valhalla Engineer Image th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
657-19-117JB
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM VEG 19.23
100% BID DOCUMENTS
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
/2
/2
:2 :0
A
M
01-GI-002
GENERAL INFORMATION AND SYMBOLS
02 35
IMPLEMENT STERILE PROCESSING
SERVICE VENTILATION REQUIREMENTS
MVP SB03/26/2020
GENERAL NOTESABBREVIATIONS SYMBOLS LEGEND
ACCESSIBILITY GUIDELINES
CODE DATA
SECTION, DETAIL, OR ELEVATION TITLE EXAMPLE
ELEVATION CALLOUT EXAMPLE
DETAIL CALLOUT EXAMPLE
SECTION CALLOUT EXAMPLE
SECTION, DETAIL, OR ELEVATION
SYMBOL IDENTIFIERS
DETAIL NAME
LETTER OR NUMBER DESIGNATOR
DRAWING SEQUENCE
NUMBER INDICATES WHERE
TITLE IS LOCATED
ONE OR TWO CHARACTER
DISCIPLINE DESIGNATOR
(MAY NOT BE PRESENT IF
CALLOUT AND TITLE ARE ON
DRAWINGS WITHIN THE SAME
DISCIPLINE)
A
A101
AE101
AE101
AE101
DOOR NUMBER TAG
WALL TYPE TAG
WINDOW TYPE TAG
CENTER LINE
WALL FINISH TAG
COLUMN BUBBLE
ROOM TAG
WALL COLOR
BASE TYPE /
COLOR
MATCH LINE
DETAIL
NUMBER
ON SHEET
SHEET NUMBER
DETAIL
NUMBER
ON SHEET
SHEET NUMBER
NEW LINE TYPE.
EXISTING LINE TYPE.
DEMO LINE TYPE.
DEMO HATCH TYPE.
FIRE RESISTIVE RATED WALL, 1 HOUR
FIRE RESISTIVE RATED WALL, 2 HOUR
FIRE RESISTIVE RATED WALL, 3 HOUR
FIRE RESISTIVE RATED WALL, 4 HOUR
S
S
S
S
FIRE RATED, SMOKE BARRIER WALL, 1 HOUR
FIRE RATED, SMOKE BARRIER WALL, 1 HOUR
FIRE RATED, SMOKE BARRIER WALL, 1 HOUR
FIRE RATED, SMOKE BARRIER WALL, 1 HOUR
A
ROOM NAME
P2
RB3
W-3
View Name 1/8" = 1'-0"1
MIRROR
CLEAR
FLOOR
SPACE
MIRROR
TOILET PAPER
(H) ACCESSIBLE TOILET WITH GRAB BAR (I) ACCESSIBLE TOILET WITH GRAB BAR
PULL SIDE PUSH SIDE
(D) FRONT APPROACHES - SWING DOORS
4'-0" MIN. IF
DOOR HAS
BOTH LATCH
AND CLOSER
* IF DOOR HAS BOTH A
CLOSER AND LATCH
IF WIDTH IS 5', CLR. LENGTH IS 3'-0" MIN.
IF WIDTH IS 4'-6", CLR. LENGTH IS 3'-6" MIN.
4'-0" MAX. IF DOOR
HAS BOTH A CLOSER
AND LATCH.
(G) HINGE-SIDE APPROACHES - SWING DOORS
4'-6" MIN. IF DOOR HAS CLOSER
(K) LATCH-SIDE APPROACHES - SWING DOORS
4'-0" MIN. IF
DOOR HAS
BOTH A LATCH
AND CLOSER
(A) CLEAR FLOOR SPACE, PARALLEL APPROACH (B) HIGH AND LOW SIDE REACH
(C) MAXIMUM SIDE REACH
OVER OBSTRUCTIONS
(E) LAVATORY CLEARANCES (F) DRINKING FOUNTAIN SPOUT HEIGHT
AND KNEE CLEARANCES
(J) ROLL-IN SHOWER WITH FOLDING SEAT
DRAIN
NAPKIN DISPOSAL
2'-0" 2'-2"
M A
X
0'-10"
MAX.
2'-6"
M A
X
M
IN
M
IN
M
IN
.3
M A
X
1'-5"
MIN.
M
IN
4'-0"
MIN.
19"
MAX.
0'-6"
MAX.
0'-8"
MIN.
1'-5"
MIN.
M A
X
M
IN
M
IN
0'-6"
MAX.
0'-8"
MIN.
T O
1'-0"
MAX.
T O
3'-6"
MIN.
3'-0" 1'-6"
TYP.
1'-0"1'-0"
3'-0"
MIN.
T O
T O
1'-6" MIN.
2'-0" PREFERRED.
M
IN
M
IN
1'-0"
MIN.
W
ID
T H
CLR. LENGTH
M
IN
4'-6"
MIN.
M
IN
2'-0"
MIN.
2'-0"
MIN.
M
IN
2'-0"
MIN.
3'-0"
MIN.
& AND
@ AT
AB ANCHOR BOLT
ACFL ACCESS FLOOR
ACT ACOUSTIC CEILING TILE
AD AREA DRAIN
ADJ ADJUSTABLE
ADJT ADJACENT
ADMIN ADMINISTRATION
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
AP ACCESS PANEL
APROX APPROXIMATE
ARCH ARCHITECTURAL
AT ACOUSTICAL CEILING TILE
AUTO AUTOMATIC
AWT ACOUSTICAL WALL TREATMENT
BD BOARD
BFE BOTTOM FOOTING ELEVATION
BG BUMPER GUARD
BKT BRACKET
BLDG BUILDING
BM BEAM
BOT BOTTOM
BP BRICK PAVING
BR BRICK
BRG BEARING
BSMT BASEMENT
C CHANNEL
CAB CABINET
CANTL CANTILEVER
CAP CAPACITY
CAT CATEGORY
CIP CAST-IN-PLACE
CCTV CLOSED CIRCUIT TELEVISION
CG COILING GRILLE
CGD CORNER GUARD
CH COAT HOOK
CJT CONTROL JOINT
CL CENTER LINE
CLS CLASS
CLG CEILING
CLR CLEAR
CM CONSTRUCTION MANAGER
CMU CONCRETE MASONRY UNIT
CO CASED OPENING
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CONN CONNECT/-ED/-ION
CONST CONSTRUCTION
CONT CONTINUE/CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CP CARPET
CPT CARPET MODULE TILE
CR-1 CHAIR RAIL
CR-2 CRASH RAIL
CT CERAMIC TILE
CTR CENTER
CW CURTAIN WALL
CWR COLD WATER
CYL CYLINDER
D DEPTH OR DEEP
DEMO DEMOLITION
DEPR DEPRESSION
DBL DOUBLE
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DIST DISTRIBUTION
DIV DIVISION
DN DOWN
DP DATA PROCESSING
DR DOOR
DS DOWNSPOUT
DWG DRAWING
ELC ELECTRICAL CABINET
EC EPOXY COATING
EF EXHAUST FAN
EFTR EXISTING FINISH TO REMAIN
EJT EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EMERG EMERGENCY
EO ELECTRICAL OUTLET
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXH EXHAUST HOOD
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
EXT-P EXTERIOR PAINT
EXT-ST EXTERIOR STAIN
FA FIRE ALARM
FAP FIRE ALARM PANEL
FB FIRE BLANKET
FD FLOOR DRAIN
FDN FOUNDATION
FDV FIRE DEPARTMENT VALVE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FGS FOAM GASKET SEAL
FH FIRE HOSE
FHV FIRE HOSE VALVE
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FL FLOW LINE
FP FIRE PROOFING
H HIGH
HB HOSE BIB
HD HAND DRYER
HDCP HANDICAP
HDR HEADER
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HPT HIGH POINT
HR HANDRAIL
HT HEIGHT
HTR HEATER
HVAC HEATING, VENTILATING,
AIR CONDITIONING
HW HOT WATER
HWD HARDWOOD
IB INTEGRATED BASE
ID INSIDE DIAMETER
IN INCH
INSUL INSULATION
INT INTERIOR
ISO ISOLATION
JAN JANITOR
JB JUNCTION BOX
JST JOIST
JT JOINT
KO KNOCK OUT
L LAVATORY
LB POUND
LCD LINEAR CEILING DIFFUSER
LF LINE FIGURED
LIN LINEAR
LKR LOCKER
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMC LINEAR METAL CEILING
LOC LOCATION OR LOCATE
LPT LOW POINT
LS LAWN SPRINKLING
LT LIGHT
LTG LIGHTING
LVR LOUVER
LWC LINEAR WOOD CEILING
MAT MATERIAL
MAX MAXIMUM
MBD MARKER BOARD
MC MEDICINE CABINET
MCU MODULAR COOLING UNIT
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MRF MANUFACTURER
MH MANHOLE
MIL MILLIMETER
MN MINIMUM
MR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MONO MONOLITHIC
MPU MULTI- PURPOSE UNIT
MTD MOUNTED
MTL METAL
MTR MOTOR
MULL MULLION
PNL PANEL
PNT PAINT
PRELIM PRELIMINARY
PRES PLASTIC RESIN
PRESS PRESSURE
PRIM PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PTC PAPER TOWEL CABINET
PTR PRINTER
PVC POLYVINYL CHLORIDE
R RADIUS
RI RISER
RA RETURN AIR
RB RESILIENT BASE/RUBBER BASE
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REIN REINFORCE/-ED/-ING
REM REMOVE
REQD REQUIRED
RET RETAINING
REVS REVERSE
REV REVISE
RF RESILIENT FLOOR
RFI REQUEST FOR INFORMATION
RH ROOF HATCH
RM ROOM
RO ROUGH OPENING
RS ROUGH SLAB
RSF RESILIENT SHEET FLOOR
RWC RAIN WATER CONDUCTOR
SI SINK
SCHED SCHEDULE
SD SHOWER DRAIN
SDR SMOKE DAMPER
SDISP SOAP DISPENSER
STF STORE FRONT
SF SQUARE FOOT
SH SHOWER
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SM SURFACE MOUNTED
SNC SANITARY NAPKIN CABINET
SND SANITARY NAPKIN DISPOSER
SP STANDPIPE
SPEC SPECIFICATIONS
SPR SINGLE PLY ROOF
SQ SQUARE
SQ YD SQUARE YARD
SR SERVICE RECEPTOR
SS SERVICE SINK
SST STAINLESS STEEL
STR STREET
ST STONE TILE
STC SOUND TRANSMISSION
STD STANDARD
STL STEEL
STOR STORAGE
STRUC STRUCTURAL
T TOP
TAN TANGENT
TCAB TOWEL CABINET
TDR TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TG TONGUE & GROVE
THRES THRESHOLD
TOIL TOILET
TPH TOILET PAPER HOLDER
TR TREAD
TRANSF TRANSFORMER
TS TUBE SECTION
TV TELEVISION
TYP TYPICAL
U URINAL
UCT UNDERCUT
UCR UNDERCOUNTER
UFD UNDER FLOOR DUCT
UG UNDERGROUND
UH UNIT HEATER
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
US UTILITY SHELF
UTIL UTILITY
VIF VERIFY IN FIELD
VC VALVE CABINET
VCT VINYL COMPOSITION TILE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
WCV WALL COVERING
W WIDTH/WIDE
WF WIDE FLANGE
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDW WINDOW
WG WALL GUARD
WH WALL HYDRANT
WHCH WHEELCHAIR
WHTR WATER HEATER
WPL WALL PANEL
WP WATERPROOF
WR WASTE RECEPTACLE
WS WEATHERSTRIP
WSCT WAINSCOT
WSF WELDED SEAM-RESILIENT
SHEET FLOORING
WDT WINDOW TREATMENT
WT WEIGHT
WW WOOD WINDOW
WWF WELD WIRE FABRIC
NA NOT APPLICABLE
NC NURSE CALL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NT NOTE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OVERHEAD
OP OPERABLE PARTITION
OPER OPERATOR
OPNG OPENING
OPP OPPOSITE
OFD OVERFLOW ROOF DRAIN
FRMG FRAMING
FSTOP FIRE STOPPING
FT FOOT/FEET
FTG FOOTING
FURR FURRING
GA GAUGE
GAL GALLONS
GALV GALVANIZED
GB GRAB BAR
GBM GRADE BEAM
GC GENERAL CONTRACTOR
GENL GENERAL
GENR GENERATOR
GL GLASS
GR GRADE
GRT GROUT
GWB GYPSUM WALLBOARD
GYP GYPSUM
PART PARTITION
PB PORCELAIN BASE
PC PRECAST CONCRETE
PCD PAPER CUP DISPENSER
PED PEDESTAL
PLT PLATE
PROP PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLS PLASTER
PLW PLYWOOD
COR CONTRACTING OFFICER'S
REPRESENTATIVE
1. ALL CONTRACTORS AND THEIR SUPERVISORY PERSONNEL MUST REVIEW THE GENERAL AND
SUPPLEMENTARY CONDITIONS TO THE CONTRACT.
2. ALL WORK MUST CONFORM WITH APPLICABLE BUILDING CODES, REGULATIONS AND ORDINANCES.
3. CONTRACTOR MUST OBTAIN ALL REQUIRED BUILDING AND OCCUPANCY PERMITS, WHEN APPLICABLE.
4. CONTRACTOR MUST BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE WORK.
5. CONTRACTOR MUST BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION AND THE SAFETY OF ALL CONSTRUCTION PERSONNEL AND VISITORS.
6. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE CONTRACTOR.
7. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE WORK WILL BE INSTALLED AND REPORT TO THE COR IN WRITING ANY CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THAT INSTALLER'S WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. COMMENCING WITH INSTALLATION WILL CONSTITUTE ACCEPTANCE OF THE
SUBSTRATE AND/OR CONDITIONS.
8. DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS AND NOTES. CONTACT COR FOR CLARIFICATIONS, IF REQUIRED.
9. DIMENSIONS SHOWN ON THE FLOOR PLAN ARE TO THE FACE OF GYP. BOARD/ WALL (FOG), FACE OF MASONRY (FOM), FACE OF CONCRETE WALLS (FOC) AND COLUMN GRID LINES, UNLESS OTHERWISE NOTED OR
INDICATED.
10. WALL THICKNESSES ARE NOMINAL DIMENSIONS, NOT ACTUAL DIMENSIONS. ALL STUD WALL THICKNESSES
ARE 5 INCHES, UNLESS DIMENSIONED OTHERWISE.
11. ALL MASONRY WALL THICKNESSES ARE 8 INCHES, UNLESS DIMENSIONED OTHERWISE.
12. "TYPICAL", AS USED IN THESE DOCUMENTS, MEANS THAT THE CONDITION OR DIMENSION IS REPRESENTATIVE
OF, OR THE SAME AS, FOR SIMILAR CONDITIONS THROUGHOUT.
13. IF THERE IS A DISCREPANCY BETWEEN SMALL SCALE AND LARGE SCALE DRAWINGS, (PLAN, SECTION, & DETAIL DRAWINGS, ETC.), CONTACT COR FOR CLARIFICATION. FOR BIDDING PURPOSES, THE MOST EXPENSIVE AND/OR STRICTEST REQUIREMENTS MUST GOVERN. FOR CLARIFICATIONS DURING CONSTRUCTION, THE MOST
EXPENSIVE AND/OR STRICTEST REQUIREMENTS, AS INDICATED BY THE COR, MUST GOVERN.
14. IF THERE ARE ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT COR FOR CLARIFICATION. FOR BIDDING PURPOSES, THE MOST EXPENSIVE AND/OR STRICTEST REQUIREMENTS MUST GOVERN. FOR CLARIFICATIONS DURING CONSTRUCTION, THE MOST EXPENSIVE AND/OR STRICTEST
REQUIREMENTS, AS INDICATED BY THE COR, MUST GOVERN.
15. ANY AND ALL DISCREPANCIES MUST BE REPORTED TO THE COR IN WRITING FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK. IN THESE INSTANCES, NO CHANGE ORDERS OR EXTENSIONS OF TIME WILL BE ALLOWED OR ACCEPTED FOR PROCEEDING WITH THE WORK WITHOUT THE COR'S WRITTEN DIRECTION AND APPROVAL. ALSO, CONTRACTOR MUST REPAIR AND/OR REPLACE ANY UNAUTHORIZED WORK, AS INDICATED
BY THE COR, AT NO ADDITIONAL COST TO THE OWNER.
16. ALL DISSIMILAR METAL MATERIALS MUST BE ISOLATED WITH AN APPROVED NONMETAL ISOLATION MATERIAL.
17. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALL PANELS AND AT PENETRATIONS OF UTILITIES THROUGH THE BUILDING ENVELOPE, ETC, MUST BE SEALED, CAULKED, FLASHED OR WEATHER-STRIPPED, AS REQUIRED, FOR COMPATIBILITY WITH ADJACENT
MATERIALS AND TO ELIMINATE AIR LEAKAGE AND WATER ENTRY.
18. PROVIDE SEALANT AND/OR CAULKING BETWEEN DISSIMILAR ADJOINING INTERIOR MATERIALS. (I.E. WINDOW
SILLS TO GYP. BD., ACT CEILINGS TO MASONRY WALLS, ETC.)
19. DOOR OPENINGS NOT LOCATED BY DIMENSION MUST BE CENTERED IN WALL SHOWN OR LOCATED 2 INCHES FROM FINISH WALL TO FINISH JAMB, ALWAYS ALLOWING A MINIMUM OF 18" FROM THE PULL SIDE OF THE DOOR
TO THE INTERSECTING WALL.
20. CONTRACTOR MUST VERIFY THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES AND THEIR SERVICE
CONNECTIONS WITH THE PROPER UTILITY COMPANY.
21. CONTRACTOR MUST COORDINATE SIZE, LOCATIONS AND NUMBER OF ALL ROOF OPENINGS AND ROOF ACCESSORIES WITH ALL OTHER TRADES. REFER TO THE ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS.
22. LOCATIONS AND SIZES OF ALL CONCRETE MECHANICAL AND ELECTRICAL PADS MUST BE COORDINATED BY
THE MECHANICAL AND ELECTRICAL CONTRACTORS WITH THE SELECTED EQUIPMENT
MANUFACTURER/SUPPLIER AND ARE TO BE APPROVED BY THE COR PRIOR TO PROCEEDING WITH THE WORK.
23. EXCEPT AT FIRE-RATED PARTITIONS, ALL WALL AND COLUMN GYPSUM BOARD FACING MUST BE HELD AT 5/8
INCH BELOW STRUCTURE, UNLESS DETAILED OR NOTED OTHERWISE.
24. AT ALL TELECOMMUNICATION ROOMS: PROVIDE 3/4" X 8'-0" HIGH FIRE-RETARDANT-TREATED WOOD SHEATHING OR PROVIDE PLYWOOD OVER NON-COMBUSTIBLE SHEATHING. BOTTOM TO BE LOCATED AT 4"
A.F.F. VERIFY LENGTHS AND LOCATIONS WITH ELECTRICAL DRAWINGS.
25. GLASS DOORS, ADJACENT PANELS AND ALL GLAZED OPENINGS WITHIN 1'-6" OF THE FLOOR AND WITHIN A 24- INCH ARC OF EITHER VERTICAL EDGE OF A DOOR, ETC., MUST BE SAFETY GLAZING AS APPROVED FOR IMPACT
BY APPLICABLE BUILDING CODES, AND MUST BE LABELED AS SUCH.
26. ALL CEILING HEIGHTS AS SHOWN ON PLANS AND DETAILS ARE FROM SLAB OR TILE FLOOR (FINISHED FLOOR)
TO FINISHED CEILING.
27. PROVIDE INDEPENDENT FRAMING AND ATTACHMENTS TO THE STRUCTURE, ADEQUATE TO SUPPORT THE CEILING SYSTEM, LIGHT FIXTURES, DUCTS, DIFFUSERS, SPRINKLER PIPING AND BUS DUCTS.
28. ALL CLOSETS AND ALCOVES WITHOUT A SPACE IDENTIFICATION NUMBER MUST HAVE THE SAME FINISHES AS
ADJOINING SPACES.
29. CONTRACTOR TO INSTALL WOOD BLOCKING AND PLYWOOD, AS REQUIRED, FOR THE MOUNTING OF ALL TOILET ACCESSORIES, MILLWORK/ CASEWORK, AV EQUIPMENT, MEP ITEMS AND RADIOLOGY EQUIPMENT, ETC.
30. REFER TO SPECIFICATIONS FOR ALL REQUIRED TESTING AND INSPECTIONS.
31. ANY/ ALL PROPRIETARY PRODUCTS DESCRIBED AND/OR DRAWN IN THE DOCUMENTS (BUT NOT SPECIFIED) ARE TO MEET THE MANUFACTURER'S STANDARD CRITERIA WHICH IS NOT LIMITED TO THE FOLLOWING:
PERFORMANCE REQUIREMENTS, QUALITY ASSURANCE REQUIREMENTS, APPLICABLE CODES AND INDUSTRY STANDARDS, FABRICATION, ASSEMBLY, HANDLING, DELIVERY, STORAGE, INSTALLATION, OPERATION, ADJUSTMENTS, ETC. PROVIDE THE MANUFACTURER'S STANDARD WARRANTY AND STANDARD FINISH WARRANTY. PROVIDE PRODUCT DATA, SHOP DRAWINGS, SAMPLES AND MAINTENANCE DATA, AS REQUIRED.
REFER TO DIVISION 01 SPECIFICATION SECTIONS WHICH ALSO APPLY, SUCH AS SUBSTITUTION PROCEDURES, SUBMITTAL PROCEDURES, QUALITY REQUIREMENTS, REFERENCES, EXECUTION AND CLOSEOUT PROCEDURE.
ANY SUBSTITUTIONS MUST MEET THE DESIGN INTENT, AS WELL AS THE CRITERIA DESCRIBED ABOVE.
AE101
DETAIL
NUMBER
ON SHEET
SHEET NUMBER
INTERIOR EXTERIOR
PT PORCELAIN TILE
STN STAIN
PR PAIR
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD
APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL)
(WWW.CFM.VA.GOV/TIL/)
• INTERNATIONAL BUILDING CODE (IBC)
(ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• NFPA NATIONAL FIRE CODES, WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
• VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• NATIONAL ELECTRICAL CODE (NEC)
• INTERNATIONAL PLUMBING CODE
• ASME CODE FOR PRESSURE PIPING
• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE (PG-18-13)
• ENERGY POLICY ACT OF 2005 (EPAct)
• EXECUTIVE ORDER13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND
TRANSPORTATION MANAGEMENT
• THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS
SECTION 01 00 00 OF THE VA MASTER CONSTRUCTION SPECIFICATION
• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY -- ASHRAE STANDARD 62.1-2004
LOCAL CODES:
AS AN AGENCY OF THE FEDERAL GOVERNMENT, THE VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES.
HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN
OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT THE VA DOES NOT PAY FOR REVIEW OR
INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY
CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS
REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED IN THE PROGRAM GUIDE PG-18-3.
FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A
DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT
REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC
REQUIREMENTS ARE DIFFERENT).
2. SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED
CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE VA.
THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR
THE VA TO ENSURE CONSISTENCY SYSTEM WIDE.
APPLICABLE CODES AND STANDARDS
BUILDING CONSTRUCTION: TYPE I-B
BUILDING OCCUPANCY: B - BUISINESS
BUILDING IS FULLY SPRINKLERED
PROJECT DESCRIPTION: RENOVATION OF MULTIPLE SPACES, HOWEVER THERE ARE NO CHANGES TO
OCCUPANCY TYPE OR OCCUPANCY LOAD.
CODE INFORMATION
R.3
R.1
R.2
S
U
V.3
T
V.2
V
V.1
1 2 3 4 5 7 9 10
RECEIVING
GE17
STORAGE
GE19
OFFICE
GE20
OFFICE
GE21
PREP. RM.
GE32
DECONTAMINATION
AREA
GE29
STEAM
RM.
GE28
R.3
R.1
R.2
S
U
V.3
T
V.2
V
V.1
1 2 3 4 5 7 9 10
CORRIDOR
H003
ELEVATOR
#2 E2
HAC
GE35
HAC
GE34
CORRIDOR
H004
TOILET
GE22
TOILET
GE23
CORRIDOR
GE31
CORRIDOR
H005
MECH.
RM.
GE26
MEDICAL
RECORDS
GC09
STORAGE
GE32A
HAC
GE24
D.W.
E3
CHASE
CH-C-1
FE
1 DEMOLISH EXISTING DOOR AND HOLLOW
METAL FRAME.
DEMOLISH A PORTION OF THE EXISTING
CONCRETE MASONRY WALL AND
ASSOCIATED CONSTRUCTION TO
FACILITATE INSTALLATION OF NEW DOOR
OPENING. PREP SUBFLOOR FOR NEW
FLOORING.
REMOVE EXISTING FLOORING AND PREP
SUBFLOOR FOR NEW FLOORING.
DEMOLISH TWO EXISTING GLASS BLOCKS IN
UPPER ROW TO FACILITATE INSTALLATION
OF NEW 16" X 8" EXHAUST LOUVER.
DEMOLISH EXISTING LOUVER AND
ASSOCIATED CONSTRUCTION TO
FACILITATE INSTALLATION OF NEW LOUVER
IN EXISTING OPENING.
DEMOLITION KEYNOTES
1. EXISTING FLOOR PLAN AND LAYOUT IS PER VA
JOB # 657-19-JBAB DATED 03/19/2019.
DIMENSIONS FOR ROOM GE17 - RECEIVING
HAVE BEEN VERIFIED AND UPDATED. OTHER
DIMENSIONS SHOULD BE FIELD VERIFIED BY
GC, AS REQUIRED. REPORT ANY
DISCREPENCIES FROM THE DRAWINGS TO COR
BEFORE PROCEEDING WITH WORK.
2. REFER TO ELECTRICAL AND MECHANICAL
PLANS FOR ADDITIONAL INFORMATION AND
EXTENT OF ELECTRICAL AND MECHANICAL
DEMOLITION
GENERAL NOTES
P la n N o rt h
T ru e N o rt h
BLDG 1
KEYPLAN
WEST
WING
CENTER
WING
EAST
WING
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
657-19-117JB
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM VEG 19.23
100% BID DOCUMENTS
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
/2
/2
:2 :0
A
M
01-AD-100
ARCHITECTURAL DEMOLITION PLAN -
FLOOR 00
03 35
IMPLEMENT STERILE PROCESSING
SERVICE VENTILATION REQUIREMENTS
MVP SB03/26/2020
1/4" = 1'-0"
ARCHITECTURAL DEMOLITION PLAN - FLOOR 00
1 Plan North
True North
R.3
R.1
R.2
S
U
V.3
T
V.2
V
V.1
1 2 3 4 5 7 9 10
CORRIDOR
H003
ELEVATOR
#2 E2
HAC
GE35
HAC
GE34
OFFICE
GE17
MEDICAL
RECORDS
GE19
CORRIDOR
H004
MEDICAL
RECORDS
GE21
MEDICAL
RECORDS
GE20
MEDICAL
RECORDS
GE32
TOILET
GE22
TOILET
GE23
CORRIDOR
GE31
CORRIDOR
H005
MEDICAL
RECORDS
GE29
MECH.
RM.
GE26
MEDICAL
RECORDS
GC09
STORAGE
GE32A
MEDICAL
RECORDS
GE28
HAC
GE24
D.W.
E3
CHASE
CH-C-1
FE
A
A
A
A
8 EXISTING FLOORNEW FLOOR
1. EXISTING FLOOR PLAN AND LAYOUT IS PER VA
JOB # 657-19-JBAB DATED 03/19/2019.
DIMENSIONS FOR ROOM GE17 - RECEIVING
HAVE BEEN VERIFIED AND UPDATED. OTHER
DIMENSIONS SHOULD BE FIELD VERIFIED BY
GC, AS REQUIRED. REPORT ANY
DISCREPENCIES FROM THE DRAWINGS TO COR
BEFORE PROCEEDING WITH WORK.
GENERAL NOTES
1 INFILL WITH NEW CONCRETE MASONRY
UNITS IN ACCORDANCE WITH
SPECIFICATION SECTION 04 20 00. PAINT TO
MATCH EXISTING. MATCH EXISTING BOND
PATTERN.
PROVIDE NEW (PR) 3'-0" X 7'-0" WOOD DOOR
AND HM FRAME. INSTALL NEW 9" ALUMINUM
DOOR THRESHOLD PER SPECIFICATION
SECTION 08 71 00 SECTION 2.23. BASIS OF
DESIGN: NGP 913 UTILITY THRESHOLD, MILL
FINISH ALUMINUM.
UPDATE FINISHES PER FINISH SCHEDULE.
REFER TO SHEET 01-AE-501.
EXISTING FURNITURE PROVIDED BY THE VA
TO BE RELOCATED FROM THE EXISTING
DECONTAMINATION AREA.
INSTALL NEW 16" X 8" EXHAUST LOUVER.
INSTALL PER MANUFACTURER'S
RECOMMENDATIONS AND SEAL ALL
AROUND TO PREVENT WATER
INFILTRATION. REPLACE IN KIND ANY
GLASS BLOCK DAMAGED DURING
INSTALLATION. SEE MECHANICAL
DRAWINGS FOR MORE INFORMATION.
INSTALL NEW LOUVER IN EXISTING
OPENING. INSTALL PER MANUFACTURER'S
RECOMMENDATIONS AND SEAL ALL
AROUND TO PREVENT WATER
INFILTRATION. SEE MECHANICAL
DRAWINGS FOR MORE INFORMATION.
INSTALL NEW STEEL ANGLE LOOSE LINTEL
IN ACCORDANCE WITH SPECIFICATION
SECTION 05 50 00. IF EXISTING
REINFORCEMENT IS CUT DURING
INSTALLATION, INSTALL #4 VERTICAL REBAR
ON EITHER SIDE OF OPENING IN
ACCORDANCE WITH SPECIFICATION
SECTION 04 20 00. THE GENERAL
CONTRACTOR SHALL PROVIDE SHORING,
AS REQUIRED, DURING INSTALLATION.
CONSTRUCT NEW RATED WALL ON TOP OF
EXISTING CMU WALL. REFER TO EALL TYPE
SCHEDULE ON SHEET 01-AE-501.
KEYNOTES
P la n N o rt h
T ru e N o rt h
BLDG 1
KEYPLAN
WEST
WING
CENTER
WING
EAST
WING
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
657-19-117JB
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM VEG 19.23
100% BID DOCUMENTS
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
/2
/2
:2 :0
A
M
01-AE-100
ARCHITECTURAL FLOOR PLAN - FLOOR
04 35
IMPLEMENT STERILE PROCESSING
SERVICE VENTILATION REQUIREMENTS
MVP SB03/26/2020
1/4" = 1'-0"
ARCHITECTURAL FLOOR PLAN - FLOOR 00
1 Plan North
True North
(2) LAYERS 5/8" TYPE X GYP.
BD. EACH SIDE. FINISH WITH
TAPE AND JOINT COMPOUND
ONLY
4" METAL STUD @ 24" O.C. W/
HORIZ. BRACING AS REQ'D
3 1/2" SOUND BATT INSULATION
METAL RUNNERS TOP AND
BOTTOM
BOTTOM OF DECK
CEILING HEIGHT
VIF
FLOOR
DEEP LEG DEFLECTION/ SLIP
TRACK
INSTALL FIRESAFING SEALANT
TO SEAL TOP & BOTTOM OF
NEW WALL
EXISTING CMU WALL
ANCHOR NEW WALL TO EXISTING
WITH POWER ACTUATED
FASTENERS @ 16" OC INTO CMU
HEAD JOINT
SUSPENDED CEILING (WHERE
APPLIES)
MECHANICAL ROOM
LVT / VCT
WSF
B.O.D. SCHLUTER-
RENO-T
CAPPING STRIP
SHEET VINYL FLOORING WITH INTEGRAL
COVE BASE AS SCH.
MANUF. STANDARD COVE FILLER
EXISTING CMU WALL
PROVIDE NEW STEEL ANGLE
LINTEL PER SPECIFICATION
SECTION 05 50 00
ELASTORMERIC SEALANT
(ALL AROUND, BOTH SIDES)
6" HM RENOVATION FRAME
(PAINTED)
COUNTERSUNK FASTENER
INTO STEEL LINTEL @ 24" OC
SCHEDULED DOOR
SCHEDULED DOOR
6" HM RENOVATION
FRAME (PAINTED
EXISTING CMU WALL
COUNTERSUNK FASTENER INTO
MORTAR BED JOINT AT 24" OC
VERT
ELASTORMERIC SEALANT (ALL
AROUND, BOTH SIDES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
657-19-117JB
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM VEG 19.23
100% BID DOCUMENTS
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
/2
/2
:2 :0
A
M
01-AE-501
ARCHITECTURAL WALL TYPES AND
DETAILS
05 35
IMPLEMENT STERILE PROCESSING
SERVICE VENTILATION REQUIREMENTS
MVP SB03/26/2020
WALL TYPE A
WALL DESCRIPTIONTYPE
A
• UL-U403
• (2) LAYERS 5/8" TYPE X GYPSUM BOARD
• 3 5/8" 25 GA. STEEL STUDS @ 16" O.C.
• 3 1/2" GLASS FIBER INSULATION
• (2) LAYERS 5/8" TYPE X GYPSUM BOARD
FINISH LEGEND
SYMBOL MATERIAL MANUFACTURER TYPE COLOR TYP. AREA / REMARKS
FLOOR FINISH
WSF WELDED SEAM SHEET FLOORING ARMSTRONG MEDINTECH - -
WALL BASE
IB INTEGRAL SHEET VINYL COVE BASE W/ METAL
TERMINATION STRIP - 4" H. COVE
ARMSTRONG MEDINTECH -
WALL FINISH
PNT PAINT SHERWIN WILLIAMS EPOXY - -
CEILING FINISH
ACT 24" X 48" ACOUSTIC CEILING TILE ARMSTRONG DUNE: 1851 WHITE MINERAL FIBER, SMOOTH
6" = 1'-0"
WSF TO VINYL / VCT
3" = 1'-0"
INTEGRAL COVE BASE DETAIL
1 1/2" = 1'-0"
TYP. INTERIOR DOOR HEAD DETAIL
1 1/2" = 1'-0"
TYP. INTERIOR DOOR JAMB DETAIL
GENERAL NOTES
1. CONTRACTOR SHALL PROVIDE AN INFECTION CONTROL RISK ASSESSMENT
BARRIER AROUND THE PROJECT AREA CONSISTENT WITH THE CONTRACTOR'S
PHASING PLAN AS APPROVED BY THE VA.
HVAC GENERAL NOTES
1. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN
A FURRED CHASE OR ABOVE THE HARD SUSPENDED CEILING.
2. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR
INDICATED. DUCT SIZES ARE NET INSIDE DIMENSIONS.
3. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES,
TRAPS, DAMPERS, CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL BE
FURNISHED AND INSTALLED UNDER THE ARCHITECTURAL SPECIFICATIONS.
4. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES INCLUDES DUCT SYSTEM,
TERMINAL UNITS, FILTERS, COILS, ETC.
5. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS TO EQUIPMENT, SEE
EQUIPMENT DETAILS.
6. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR PLANS ARE NECK
SIZES.
7. WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING COILS SHALL BE MADE
TO PROVIDE COUNTER FLOW BETWEEN WATER AND AIR.
8. WALL TYPE EXHAUST REGISTERS NOTED AS "BR" ON DRAWINGS ARE TO BE
INSTALLED WITH BOTTOM ELEVATION OF REGISTER AT 7" ABOVE FINISHED FLOOR.
9. ALL PRESSURES LISTED ARE GAGE PRESSURE UNLESS NOTED OTHERWISE.
10. ALL CONTROL SYSTEM EQUIPMENT SHALL BE COMPATIBLE WITH EXISTING
BUILDING MANAGEMENT SYSTEM CONTROLS. EXTEND EXISTING CONTROL
SYSTEM TO INCLUDE ALL OF THE CONTROLS AND SEQUENCES SHOWN.
11. COORDINATE EXISTING FIRE SPRINKLER HEADS AND LIGHTS WITH DIFFUSERS.
MECHANICAL ASCE 7 NONSTRUCTURAL
SEISMIC RESTRAINT AND ANCHORAGE NOTES:
REFERENCE SPECIFICATION: SECTION 13 05 41
SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS
SEISMIC DESIGN DATA FOR ANALYSIS AND DESIGN
SEISMIC RISK CATEGORY = IV
COMPONENT IMPORTANCE FACTOR IP = 1.5
MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS:
SS = 0.475G S1 = 0.166G
SITE CLASS D (ASSUMED)
DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS:
SDS = 0.449G SD1 = 0.253G
SEISMIC DESIGN CATEGORY D BASED UPON SD1 > 0.20G
CLARIFICATION OF ASCE 7 "12 INCH RULE" SUSPENDED SEISMIC BRACING CODE
EXCEPTION FOR PIPING AND HVAC DUCTWORK:
ALL PIPING SUSPENDED BY INDIVIDUAL HANGER RODS 12" OR LESS AS MEASURED
FROM THE TOP OF THE PIPE TO THE BOTTOM OF THE SUPPORT WHERE THE HANGER
IS ATTACHED. IF THE 12" LIMIT IS EXCEEDED BY ANY HANGER IN THE RUN, SEISMIC
BRACING IS REQUIRED FOR THE RUN. NOTE: A SINGLE SUPPORT LOCATION THAT
MEETS THE REQUIREMENT OF THIS EXCEPTION DOES NOT CONSTITUTE A SEISMIC
SWAY BRACE LOCATION.
THE EXCEPTION ALSO APPLIES FOR TRAPEZE SUPPORTED SYSTEMS IF THE DISTANCE
AS MEASURED FROM THE POINT OF ATTACHMENT TO THE TRAPEZE TO THE POINT OF
ATTACHMENT TO THE STRUCTURE IS LESS THAN 12". NOTE: IF DIRECTIONAL CHANGES
OR OFFSETS TO EQUIPMENT CONNECTIONS DO NOT ALLOW FOR FLEXIBILITY OF THE
TRAPEZED SYSTEM (E.G. LONG OFFSETS OR FLEXIBLE CONNECTORS) THEN THE
SYSTEM MUST BE BRACED REGARDLESS OF PIPE DIAMETER OR DISTANCE TO THE
STRUCTURE IF THE COMBINED WEIGHT PER FOOT (METER) OF ALL ITEMS IS GREATER
THAN 10 LBS/FT.
IN ADDITION, TO MEET THE CODE REQUIREMENTS, ALL OF THE FOLLOWING
CONDITIONS MUST ALSO BE SATISFIED:
1. LATERAL MOTION OF PIPING OR DUCTWORK WILL NOT CAUSE DAMAGING IMPACT
WITH SURROUNDING SYSTEMS (E.G. OTHER PIPE, DUCT, EQUIPMENT, SPRINKLER
HEADS ETC.) OR CAUSE LOSS OF SYSTEM VERTICAL SUPPORT.
2. PIPING MUST BE MADE OF DUCTILE MATERIAL WITH DUCTILE CONNECTIONS (E.G.
WELDED STEEL PIPE, BRAZED COPPER PIPE, ETC.)
3. VERTICAL SUPPORT CONNECTIONS CANNOT DEVELOP MOMENTS (E.G. SWIVEL
JOINTS, EYE BOLTS, VIBRATION ISOLATION HANGERS, ETC.)
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
657-19-117JB
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM VEG 19.23
100% BID DOCUMENTS
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
/2
/2
:2 :4
P
M
01-MG-001
MECHANICAL ABBREVIATIONS AND
GENERAL NOTES
06 35
IMPLEMENT STERILE PROCESSING
SERVICE VENTILATION REQUIREMENTS
DD ZM03/26/2020
MECHANICAL ABBREVIATIONS
RAHX ROTARY AIR HEAT EXCHANGER
RAT RETURN AIR TEMPERATURE
RCCH REMOTE CONDENSER CHILLER
RCU RECIPROCATING CHILLER UNIT
RD REFRIGERANT DISCHARGE
RDS ROOM DATA SHEETS
REA RELIEF AIR
RF RADIO FREQUENCY
RF RETURN FAN
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID LINE
RLA RUN LOAD AMPERE
RO REVERSE OSMOSIS
RPM REVOLUTIONS PER MINUTE
RR RETURN REGISTER
RS REFRIGERANT SUCTION
RTU ROOFTOP UNIT
RV RELIEF VALVE
SA SUPPLY AIR
SAD SOUND ATTENUATING DEVICE
SAT SUPPLY AIR TEMPERATURE
SC SHADING COEFFICIENT
SCFM STANDARD CUBIC FEET PER MINUTE
SCR SILICON CONTROLLED RECTIFIER
SD SMOKE DETECTOR
SD SUPPLY AIR DIFFUSER
SD-1 SCHEMATIC DESIGN SUBMISSION 1
SD-2 SCHEMATIC DESIGN SUBMISSION 2
SDPR SMOKE DAMPER
SDR SMOKE DAMPER (RETURN)
SDS SMOKE DAMPER (SUPPLY)
SEN SENSIBLE HEAT
SF SUPPLY FAN
SG SUPPLY AIR GRILLE
SH STEAM HUMIDIFIER
SHC STEAM HEATING COIL
SI SQUARE INCHES
SP STATIC PRESSURE
SP GR SPECIFIC GRAVITY
SPD SUPPLY PROCESS AND DISTRIBUTION
SPRV STEAM PRESSURE REDUCING VALVE
SPS STATIC PRESSURE SENSOR
SQ FT SQUARE FOOT
SR SUPPLY AIR REGISTER
SS STAINLESS STEEL
SSHX STEAM TO STEAM HEAT EXCHANGER
SSR SOLID SEPARATOR
ST STEAM TRAP
SUH STEAM UNIT HEATER
SV STEAM PRESSURE REDUCING VALVE
SVS STEAM VENT SILENCER
SWHX STEAM TO WATER HEAT EXCHANGER
T&PCV TEMPERATURE AND PRESSURE CONTROL VALVE
TAB TESTING, ADJUSTING, AND BALANCING
TD TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TDS TOTAL DISSOLVED SOLIDS
TG TRANSFER GRILLE
TP TRAP
TR TOP REGISTER
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TU TERMINAL UNIT
TWU THRU-WALL UNIT
UC UNIT COOLER
UCT UNDERCUT
UH UNIT HEATER
UL UNDERWRITER'S LABORATORY
URV UPBLAST UNIT VENTILATOR
V VALVE
VAF VANE-AXIAL FAN
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL OPPOSED BLADE)
VFD VARIABLE FREQUENCY DRIVE
VHA VETERANS HEALTH ADMINISTRATION
VI VIBRATION ISOLATOR
VIV VARIABLE INLET VANES
VP VACUUM PUMP
VPS VARIABLE PRIMARY SYSTEM
VR VACUUM (STEAM CONDENSATE) RETURN
VSD VARIABLE SPEED DRIVE
VUH VERTICAL UNIT HEATER
W WASTE
WAG WASTE ANESTHESIA GAS
WB WET BULB
WC WATER COOLED
WCCH WATER COOLED CHILLER
WCCU WATER COOLED CONDENSING UNIT
WCPU WATER COOLED HEAT PUMPS
WEF WATER COOLED PACKAGED UNIT
WF WATER FILTER
WFCV WATER FLOW CONTROL VALVE
WFM WATER FLOWMETER
WFMD WATER FLOW MEASURING DEVICE
WG WATER GAGE
WPD WATER SIDE PRESSURE DROP
YR YEAR
MECHANICAL ABBREVIATIONS
ID INSIDE DIAMETER
IFB INTEGRAL FACE AND BYPASS
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCHES OF WATER COLUMN
IN WG INCHES OF WATER, GAUGE
IN-LB INCH-POUND
IPLV INTEGRATED PART LOAD VALUE
IRH INFRARED HEATER
IS INSECT SCREEN
IU INDUCTION UNIT
IV INLET VANES
KG KILOGRAM
KG/H KILOGRAMS PER HOUR
KPA KILOPASCAL
KW KILOWATT
KWH KILOWATT HOURS
L LITER
L/H LITERS PER HOUR
L/M LITERS PER MINUTE
L/S LITERS PER SECOND
LAT LEAVING AIR TEMPERATURE
LB/H POUND PER HOUR
LF LINEAR FOOT (FEET)
LGT LEAVING GLYCOL TEMPERATURE
LH LATENT HEAT
LLHX LIQUID TO LIQUID HEAT EXCHANGER
LPG LIQUID PROPANE GAS
LPR LOW PRESSURE RETURN (STEAM CONDENSATE)
LPRC LOW PRESSURE STEAM RETURN (CLEAN)
LPS LOW PRESSURE STEAM
LPSC LOW PRESSURE STEAM (CLEAN)
LSD LINEAR SLOT DIFFUSER
LTCP LOCAL TEMPERATURE CONTROL PANEL
LVG LEAVING
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
M METER
M/S METERS PER SECOND
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAU MAKE-UP AIR UNIT
MAV MANUAL AIR VENT
MAX MAXIMUM
MB MIXING BOX
MBH 1000 BTUH
MCA MINIMUM BRANCH CIRCUIT AMPACITY
MER MECHANICAL EQUIPMENT ROOM
MERV MINIMUM EFFICIENCY REPORTING VALUE
MH MANHOLE
MHP MOTOR HORSEPOWER
MIN MINIMUM
MM MILLIMETER
MOV MOTOR OPERATED VALVE
MPR MEDIUM PRESSURE RETURN (STEAM CONDENSATE)
MPS MEDIUM PRESSURE STEAM
MRI MAGNETIC RESONANCE IMAGING UNIT
MTD MEAN TEMPERATURE DIFFERENCE
MVD MANUAL VOLUME DAMPER
MZ MULTI-ZONE
NA NOT APPLICABLE
NC NOISE CRITERIA
NC NORMALLY CLOSED
NG NATURAL GAS
NGFM NATURAL GAS FLOW METER
NO NORMALLY OPEN
NOAA NATIONAL OCEANIC & ATMOSPHERIC ADMINISTRATION
NOM NOMINAL
NPLV NON-STANDARD PART LOAD VALUE
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OAG OUTSIDE AIR GRILLE
OAI OUTSIDE AIR INTAKE
OD OUTER DIAMETER
OFM OIL FLOWMETER
OR OPERATING ROOM
P PUMP
PA PASCAL
PC PUMPED CONDENSATE
PCF POUNDS PER CUBIC FOOT
PD PRESSURE DROP
PEF PROPELLER TYPE EXHAUST FAN
PF PRE-FILTER
PG PRESSURE GAUGE
PGW PROPYLENE GLYCOL-WATER SOLUTION
PHC PREHEAT COIL
PPM PARTS PER MILLION
PRS PRESSURE REGULATING VALVE STATION
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH, ABSOLUTE
PSIG POUNDS PER SQUARE INCH, GAGE
PSS PRIMARY SECONDARY SYSTEM
PSV PRESSURE SAFETY VALVE
PTAC PACKAGED TERMINAL AIR CONDITIONER
R/E RETURN OR EXHAUST
RA RETURN AIR
RAD REFRIGERANT AIR DRYER
MECHANICAL ABBREVIATIONS
DX DIRECT EXPANSION
DXCC DIRECT EXPANSION COOLING COIL
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC EVAPORATIVE COOLER
ECC ENGINEERING CONTROL CENTER
ECU EVAPORATIVE CONDENSER UNIT
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EG EXHAUST GRILLE
EGS EMERGENCY GAS SHUTOFF
EGT ENTERING GLYCOL TEMPERATURE
EH EXHAUST HOOD
EJ EXPANSION JOINT
EMD END OF MAIN DRIP (STEAM)
ENT ENTERING
ER EXHAUST REGISTER
ERC ELECTRIC REHEAT COIL
ERP ELECTRIC RADIANT PANEL
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
ETO ETHYLENE OXIDE
EUH ELECTRIC UNIT HEATER
EWC EVAPORATIVE WATER COOLER
EWT ENTERING WATER TEMPERATURE
EX EXISTING
F FAHRENHEIT
F&T FLOAT AND THERMOSTATIC
F/SDPR COMBINATION FIRE SMOKE DAMPER
FA FREE AREA
FC FLEXIBLE CONNECTION
FCU FAN COIL UNIT (4 PIPE)
FCUC FAN COIL UNIT COOLING ONLY
FCUH FAN COIL UNIT HEATING ONLY
FCW FORWARD CURVED WHEEL (FAN)
FD FLOOR DRAIN
FD FIRE DAMPER
FF FINAL FILTER
FHX FLUE GAS/FEEDWATER HEAT EXCHANGER
FM FLOW METER
FOHX FUEL OIL HEAT EXCHANGER
FOP FUEL OIL PUMP
FOT FUEL OIL TANK
FPM FEET PER MINUTE
FPS FEET PER SECOND
FPTU FAN POWERED TERMINAL UNIT
FR FLOOR REGISTER
FRP FIBER REINFORCED POLYESTER
FS FLOW SWITCH
FSTAT FREEZESTAT
FT FEET
FT-LB FOOT-POUND
FTR FINNED TUBE RADIATION
FV FACE VELOCITY
GA GAUGE
GAL GALLONS
GH GRAVITY HOOD
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GS GALVANIZED STEEL
H HUMIDIFIER
H&CW HOT & COLD WATER
HAC HOUSEKEEPING AID CLOSET
HB HOSE BIBB
HC HEATING COIL
HD HEAD
HD HOOD
HOA HAND/OFF/AUTOMATIC
HP HEAT PUMP
HP HORSEPOWER
HPDT HIGH PRESSURE DRIP TRAP
HPR HIGH PRESSURE RETURN (STEAM CONDENSATE)
HPS HIGH PRESSURE SUPPLY (STEAM)
HRC HEAT RECOVERY COIL
HRD HEAT RECOVERY DEVICE
HRP HYDRONIC RADIANT (CEILING) PANEL
HRW HEAT RECOVERY WHEEL
HSTAT HUMIDISTAT
HTM HUMIDIFIER TERMINAL
HUM HUMIDIFIER UNIT MOUNTED
HVD HOISTWAY VENT DAMPER
HVU HEATING AND VENTILATING UNIT
HW HOT WATER
HWC HOT WATER COIL
HWHC HOT WATER HEATING COIL
HWP HEATING WATER PUMP
HWR HEATING WATER RETURN
HWS HEATING WATER SUPPLY
HWUH HOT WATER UNIT HEATER
HX HEAT EXCHANGER
HZ HERTZ
I/O INPUT/OUTPUT
IAQ INDOOR AIR QUALITY
IBT INVERTED BUCKET TRAP
ICF IN-LINE CENTRIFUGAL FAN
ICU INTENSIVE CARE UNIT
MECHANICAL ABBREVIATIONS
A/E ARCHITECT/ENGINEER
AAHX AIR TO AIR HEAT EXCHANGER
AAV AUTOMATIC AIR VENT
AB AIR BLENDER
ACC AIR COOLED CONDENSER
ACCH AIR COOLED CHILLER
ACCU AIR-COOLED CONDENSING UNIT
ACD AUTOMATIC CONTROL DAMPER, MODULATING
ACD-TP AUTOMATIC CONTROL DAMPER, TWO POSITION
ACFM ACTUAL CUBIC FEET PER MINUTE
ACU AIR CONDITIONING UNIT
AD ACCESS DOOR
AF AFTER FILTER
AFCV AIR FLOW CONTROL VALVE
AFF ABOVE FINISHED FLOOR
AFMD AIR FLOW MEASURING DEVICE
AFW AIR FOIL WHEEL (FAN)
AHU AIR HANDLING UNIT
AMP AMPERE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE
AS AIR SEPARATOR
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
AW AIR WASHER
AXF AXIAL FLOW
B BOILER
BAS BUILDING AUTOMATION SYSTEMS
BD BUTTERFLY DAMPER
BDD BACKDRAFT DAMPER
BDR BASE BOARD RADIATOR
BFP BACKFLOW PREVENTER
BFT BOILER PLANT FIRE TUBE
BG BOTTOM GRILLE
BHP BRAKE HORSEPOWER
BHW HOT WATER HEATING BOILER
BHX BOILER BLOWDOWN HEAT EXCHANGER
BIW BACKWARD INCLINED WHEEL (FAN)
BR BOTTOM REGISTER
BSC BIOLOGICAL SAFETY CABINETS
BT BLOWOFF TANK
BTC BLOWOFF TANK CONTROL VALVE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
BWT BOILER PLANT WATER TUBE
C CENTIGRADE (CELSIUS)
CC COOLING COIL
CCD COOLING COIL CONDENSATE DRAIN
CD CEILING DIFFUSER
CD-1 CONSTRUCTION DOCUMENTS (SUBMISSION 1)
CD-2 CONSTRUCTION DOCUMENTS (SUBMISSION 2)
CENT CENTRIFUGAL
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFP CHEMICAL FEED PUMP
CFT CUBIC FEET
CG CEILING GRILLE
CH CHILLER
CHP CHILLED WATER PUMP
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CHW CHILLED WATER
CI CAST IRON
CM CARBON MONOXIDE
CM CUBIC METER
CO2 CARBON DIOXIDE
COMP COMPRESSOR UNIT
COP COEFFICIENT OF PERFORMANCE
CP CONDENSATE PUMP
CR CEILING REGISTER
CS CONDENSATE STORAGE TANK
CSG CLEAN STEAM GENERATOR
CT COOLING TOWER
CTR CONTRACTOR
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CWCC CHILLED WATER COOLING COIL
CWP CONDENSER WATER PUMP
CWR CONDENSER WATER RETURN (TO COOLING TOWER)
CWS CONDENSER WATER SUPPLY (FROM COOLING TOWER)
D DAMPER -AUTOMATIC
D-1 OUTDOOR AIR DAMPER
D-2 RETURN AIR DAMPER
D-3 RELIEF AIR DAMPER
Db DRY BULB TEMPERATURE dB DECIBEL
DD-1 DESIGN DEVELOPMENT SUBMISSION 1
DD-2 DESIGN DEVELOPMENT SUBMISSION 2
DDC DIRECT DIGITAL CONTROLS
DEG DEGREES
DF DIFFUSER
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
DP DIFFUSER PLATE
DPA DIFFERENTIAL PRESSURE ASSEMBLY
DPS DIFFERENTIAL PRESSURE SENSOR
e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
657-19-117JB
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM VEG 19.23
100% BID DOCUMENTS
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
/2
/2
:2 :4
P
M
01-MG-002
MECHANICAL SYMBOLS
07 35
IMPLEMENT STERILE PROCESSING
SERVICE VENTILATION REQUIREMENTS
DD ZM03/26/2020
T
TT
M
MT
PT
TT
FT
IT
CT
SPS
SD
PDT
KR
TSL
HS
ZC
LC
LT
PDS
TSH
EPT
AT
CO2
AT
CO
AT
OC
LTCP
HVAC
ECC
TC
VSMC
PC
SC
FC
PSH
FSH
PSL
26-SF 3
26-TU-I-I
H4
H7
A
BDD
FD
VD
SUPPLY
RETURN45°
45°
N
2 1
1/24
F/S DPR
FE
AV
MV
RH
SCH
SH
TH
PS
RC
WB
CSH
SS
VR
CTPS
CTPD
FWPS
FWPD
CF
FWS
BWS
CBD
BO
TC
A
OFL
HW
SW
CW
FOR
FOS
LPG(I)
G(I)
G
HPS
HPR
MPS
MPR
LPS
LPR
PC
HWS
HWR
GHS
GHR
V
SWS
SWR
CWR
CHR
GCR
RL
RS
RHG
CWS
CHS
GCS
MW
D
GRR
GRS
X
A
PTAC
A TWU
A
FCU
FCU
A
PTACA
MB
KC
FSL
A
M
BAS
DN
DN
UP
UP
D
R
DNUP
FC
10x8
LC
M
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
SECTION LETTER
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT IS LOCATED.
SUPPLY FAN NO. 3 IN BUILDING NO. 26
EQUIPMENT ABBREVIATION (SUPPLY FAN)
ITEM NUMBER (TERMINAL UNIT NO. 1)
ITEM (TERMINAL UNIT SHOWN)
SERVED BY AIR HANDLER UNIT NO. 1
DRAWING NUMBER WHERE DRAWN
BUILDING NO. WHERE EQUIPMENT IS LOCATED
* TYPE NUMBERS REFER TO MANUFACTURER'S STANDARDIZATION SOCIETY STANDARD
PRACTICE SP-58
TEST PLUG (PRESSURE/TEMPERATURE)
AUTOMATIC AIR VENT
MANUAL AIR VENT
QUICK-COUPLE HOSE CONNECTOR
CONNECT TO EXISTING
LIMIT OF DEMOLITION
AIR SEPERATOR
TERMINAL UNIT WITH REHEAT COIL
DOUBLE DUCT MIXING BOX.
FAN POWERED VARIABLE VOLUME
TERMINAL UNIT WITH HEATING COIL.
EXISTING DUCT TO BE REMOVED
LOUVER (LOUVER SPECIFIED IN ARCHITECTURAL
SECTION.)
FLEXIBLE DUCTWORK (INSULATED)
DUCT WITH SOUND LINING
MANUAL VOLUME DAMPER
FIRE DAMPER
BACK DRAFT DAMPER
COMBINATION FIRE/SMOKE DAMPER
POINT OF CHANGE IN DUCT CONSTRUCTION BY
STATIC PRESSURE CLASS. THE NUMBER ASSIGNS
PRESSURE CLASS (IN. OF WATER) WHICH WILL
ACCOMMODATE MAXIMUM OPERATING PRESSURE
IN THE DUCT SUBSECTION. THE SYMBOL CONTINUES
THE ASSIGNMENT UNTIL THE DUCT TERMINATES OR
ANOTHER SYMBOL APPEARS. AN "N" SUPERSCRIPT
INDICATES NEGATIVE PRESSURE.
AUTOMATIC CONTROL DAMPER MODULATING
AUTOMATIC CONTROL DAMPER TWO POSITION
MANUAL SPLITTER DAMPER
STANDARD BRANCH SUPPLY OR RETURN, NO
SPLITTER (45° TAP)
DUCT MOUNTED COIL (HOT WATER OR STEAM
COIL)
DUCT MOUNTED COIL (ELECTRIC)
CONVECTOR OR RADIATOR (RECESSED)
CONVECTOR OR RADIATOR (WALL HUNG)
FLOOR MOUNTED VERTICAL RECESSED FAN COIL UNIT.
LETTER INDICATES UNIT SIZE.
FLOOR MOUNTED VERTICAL CABINET FAN
COIL UNIT. LETTER INDICATES UNIT SIZE.
THRU WALL AIR CONDITIONING UNIT.
LETTER INDICATES UNIT SIZE.
WINDOW TYPE AIR CONDITIONING UNIT.
LETTER INDICATES UNIT SIZE.
FLOOR MOUNTED HEAT PUMP. LETTER
INDICATES UNIT SIZE.
AIR CURTAIN
UNIT HEATER (HORIZONTAL)
UNIT HEATER (VERTICAL)
2'x2' RADIANT CEILING PANEL
2'x4' RADIANT CEILING PANEL
SUPPLY DUCT (UP & DOWN)
EXHAUST DUCT (UP & DOWN)
RETURN DUCT (UP & DOWN)
ROUND AND SQUARE 4-WAY CEILING DIFFUSERS
SQUARE 3-WAY CEILING DIFFUSERS
SQUARE 2-WAY CEILING DIFFUSERS
SQUARE 1-WAY CEILING DIFFUSERS
LINEAR SLOT DIFFUSER
SUPPLY TOP REGISTER OR GRILLE (WALL TYPE)
EXHAUST OR RETURN CEILING
REGISTER OR GRILLE
EXHAUST OR RETURN BOTTOM
REGISTER OR GRILLE (WALL TYPE)
EXHAUST OR RETURN REGISTER OR TOP GRILLE
(WALL TYPE)
VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFF
CONNECT NEW DUCT TO EXISTING DUCT
INCLINED RISE, IN DIRECTION OF AIR FLOW
INCLINED DROP, IN DIRECTION OF AIR FLOW
LIMIT OF DEMOLITION
FLEXIBLE CONNECTION, EQUIPMENT, VIBRATION,
OR SEISMIC
VANED ELBOW (PROVIDE ALL SQUARE OR
RECTANGULAR ELBOWS WITH VANES EVEN IF
SYMBOL IS MISSING)
VANED ELBOW (SHORT RADIUS)
STANDARD RADIUS ELBOW (LONG RADIUS)
NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)
EXISTING DUCT TO REMAIN
GATE VALVE - THREADED/FLANGED
GLOBE VALVE - THREADED/FLANGED
GATE VALVE WITH 3/4" HOSE ADAPTER
CHECK VALVE
WYE STRAINER (WITH BALL VALVE & HOSE CONNECTION)
WYE STRAINER WITH VALVED DRAIN AND QUICK-COUPLE
FLEXIBLE CONNECTION
ANGLE GLOBE VALVE
BUTTERFLY VALVE
BALL VALVE
MODULATING CONTROL VALVE
MODULATING CONTROL BUTTERFLY VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
THREE-WAY TWO POSITION CONTROL VALVE
PRESSURE REGULATING VALVE
PRESSURE SAFETY VALVE
AUTOMATIC BALANCING CONTROL VALVE
WATER BALANCE DEVICE
CIRCUIT SETTER VALVE
GATE VALVE WITH GLOBE-VALVED BYPASS
PLUG VALVE
CONTROL VALVE (CV) - FLOAT-OPERATED
PRESSURE REDUCING VALVE (PRV)
WATER LEVEL CONTROLLER
FLOW METER
ROOM THERMOSTAT/TRANSMITTER - WALL MOUNT
ROOM HUMIDISTAT (MOISTURE)/TRANSMITTER - WALL
MOUNT
TEMPERATURE TRANSMITTER
TEMPERATURE TRANSMITTER, AVERAGING ELEMENT
MOISTURE (HUMIDITY) TRANSMITTER
PRESSURE TRANSMITTER
STATIC PRESSURE SENSOR
FLOW TRANSMITTER
CURRENT TRANSMITTER
CONDUCTIVITY TRANSMITTER
SMOKE DETECTOR
PRESSURE DIFFERENTIAL TRANSMITTER
PRESSURE DIFFERENTIAL SWITCH
HAND SWITCH (HAND-OFF-AUTO SWITCH)
VALVE OR DAMPER POSITION CONTROLLER
LOCAL RECORDING TIME CLOCK (RUNTIME)
TEMPERATURE SWITCH, LOW (FREEZESTAT)
TEMPERATURE SWITCH, HIGH (FREEZESTAT)
LEVEL CONTROLLER
LEVEL TRANSMITTER
PRESSURE SWITCH HIGH
PRESSURE SWITCH LOW
ELECTRONIC TO PNEUMATIC TRANSDUCER
CARBON DIOXIDE TRANSMITTER
CARBON MONOXIDE TRANSMITTER
OCCUPANCY SENSOR
LOCAL TEMPERATURE CONTROL PANEL
HVAC CONTROL PANEL
VARIABLE SPEED MOTOR CONTROLLER
INTEGRATE CONTROL POINT ON REMOTE
GRAPHICS WORKSTATION AT ENERGY
CONTROL CENTER
TEMPERATURE CONTROLLER. SEE
SEQUENCE OF OPERATION
PRESSURE CONTROLLER. SEE SEQUENCE
OF OPERATION
SPEED CONTROLLER. SEE SEQUENCE OF
OPERATION
FLOW CONTROLLER. SEE SEQUENCE OF
OPERATION
FLOW SWITCH HIGH
FLOW SWITCH LOW
TIME CLOCK CONTROLLING EQUIPMENT ON
A SCHEDULE
TEMPERATURE SENSING ELEMENT FOR
TRANSMITTING TEMPERATURE TO EMCS
(PROVIDE 12 INCHES MINIMUM
LENGTH IN DUCT WHEN SPACE PERMITS.)
SENSOR WITH AVERAGING ELEMENT
TO TRANSMIT TEMPERATURE TO EMCS
MOTOR STARTER
ELECTRIC OPERATED CONTROL
DAMPER/OR VALVE
BUILDING AUTOMATION SYSTEM
CONTROLS SYMBOLS
DRAWING SYMBOLS
DUCTWORK SYMBOLS GENERAL PIPING SYMBOLSHVAC PIPING SYMBOLS
TERMINAL UNIT SYMBOLS
AIR TERMINAL SYMBOLS
VALVE SYMBOLS
FLOOR-SUPPORTED PIPE STAND
RISER CLAMP (TYPE 42)*
WALL BRACKET (TYPE 31, 32, 33)*
CONSTANT SUPPORT HANGER (TYPE 54, 55, 56)*
SLIDING SUPPORTS (TYPE 35)*
TRAPEZE HANGER (PROVIDE U-BOLT PIPE ATTACHMENT
TO TRAPEZE EXCEPT WHERE RH ARE INDICATED)
HOT WATER
ROLLER-TYPE HANGER
VARIABLE SPRING-TYPE HANGER (TYPE 51)*
SPRING CUSHION-TYPE HANGER (TYPE 48 OR 49)*
CLEVIS-TYPE HANGER
HIGH PRESSURE STEAM (60 PSIG AND ABOVE)
HIGH PRESSURE STEAM CONDENSATE RETURN
MEDIUM PRESSURE STEAM (16 PSIG THRU 59 PSIG)
MEDIUM PRESSURE STEAM CONDENSATE RETURN
LOW PRESSURE STEAM (15 PSIG AND BELOW)
LOW PRESSURE STEAM CONDENSATE RETURN
CONDENSATE PUMP DISCHARGE
HEATING WATER SUPPLY
HEATING WATER RETURN
GLYCOL-WATER HEATING SUPPLY
GLYCOL-WATER HEATING RETURN
SOLAR WATER SUPPLY
SOLAR WATER RETURN
REFRIGERANT LIQUID
REFRIGERANT SUCTION
REFRIGERANT HOT GAS
CONDENSER WATER SUPPLY (FROM TOWER)
CONDENSER WATER RETURN (TO TOWER)
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CHILLED GLYCOL-WATER SUPPLY
CHILLED GLYCOL-WATER RETURN
MAKE-UP WATER
DRAIN LINE
VENT LINE
GLYCOL-WATER RUN AROUND SUPPLY
GLYCOL-WATER RUN…