657-19-117JB - TES_Limited ACM Re-Inspection Report - Part 3.pdf

PDF 9 MB Posted

Attached to
Implement Sterile Processing Service Ventilation Requirements PN:657-19-117JB Federal contract opportunity
Solicitation number
36C25520R0082
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15

About this file

This notice describes a federal contract opportunity for implementing sterile processing service ventilation requirements at a Veterans Affairs medical center. The project involves demolishing existing structures, installing new ventilation systems, and related construction work with an estimated cost between $500,000 to $1,000,000. The NAICS code is 238220 and it is set aside for Service-Disabled Veteran-Owned Small Businesses. Interested firms must register in SAM and VetBiz databases. The solicitation will be posted on June 5th and site visits are encouraged. Questions must be submitted by email to the points of contact by the response deadline.

View the file

Other files for this federal contract opportunity

Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date

Project No.

DRAWING NO.

Project Title

Building Number

Location

Drawn

Checked

Drawing Title

V.A.M.C. ST. LOUIS, MO.

JEFFERSON BARRACKS DIVISION

ASBESTOS ASSESSMENT &

AREA LOCATION PROGRAM

V e t e r a n s

A d m i n i s t r a t i o n

U.S. GOVERNMENT PRINTING OFFICE: 1983-400-285

DateRevisions

VA FORM 08-6231, FEB. 1983

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A o n e e i g h t i n c h o n e f o t o n e q u a r t e r i n o t t h r e e e i g h t s i n o t t h r e e q u a r t e r s i n o t o n e i n o t o n e a d e h a l f i n c h e s o t t h r e e i n c h e o t o n e h a l f i n o t

F E

D C

B A

ASBESTOS CONTAINING MATERIALS

HMA GUIDE

XX HMA Numbers

XX

Sample Numbers

C.DEY

VA-JB 2018 Asbestos and

Lead Reinspection

SH1476

5-22-2019

NON-ASBESTOS GENERAL HMA GUIDE

13 Plaster

21 Drywall/Joint Compound

22 Concrete

23 Pipe dope

33 White paint on fiberglass

Riverfront Safety & Health

1139 Olive St. Suite 300

St. Louis, MO. 63101

PENTHOUSE - MISCELLANEOUS

HMA LEGEND

MISCELLANEOUS HMA - PENTHOUSE

JB-1-P-misc

J.RHYNEER

ONE

24 Fire door (PACM) - 5 units 41 Flange gasket - throughout

AutoCAD SHX Text 4E01A

AutoCAD SHX Text 4E01

AutoCAD SHX Text

%%UEAST WING PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

%%UCENTER PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

%%UELEVATOR PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text 4W01

AutoCAD SHX Text 4C02B

AutoCAD SHX Text 4C02A

AutoCAD SHX Text 4C01

AutoCAD SHX Text 4C01B

AutoCAD SHX Text 4C01A

AutoCAD SHX Text 4C02

AutoCAD SHX Text 4C03

AutoCAD SHX Text 4C03A

AutoCAD SHX Text 4C03B

DRAWING NO.

Project Title

Building Number

Location

Drawn

Checked

Drawing Title

V.A.M.C. ST. LOUIS, MO.

JEFFERSON BARRACKS DIVISION

ASBESTOS ASSESSMENT &

AREA LOCATION PROGRAM

V e t e r a n s

A d m i n i s t r a t i o n

U.S. GOVERNMENT PRINTING OFFICE: 1983-400-285

DateRevisions

VA FORM 08-6231, FEB. 1983

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A o n e e i g h t i n c e f o o t o n e q u a r t e r i n c e f o o t t h r e e e i g h t s i n c e f o o t t h r e e q u a r t e r s i n c e f o o t o n e i n c e f o o t o n e a n d o n e h a l f i n c h e e f o o t t h r e e i n c h e e f o o t o n e h a l f i n c e f o o t

F E

D C

B A

ASBESTOS CONTAINING MATERIALS

HMA GUIDE

XX HMA Numbers

XX

Sample Numbers

C.DEY

VA-JB 2018 Asbestos and

Lead Reinspection

SH1476

5-21-2019

NON-ASBESTOS GENERAL HMA GUIDE

13 Plaster

Riverfront Safety & Health

1139 Olive St. Suite 300

St. Louis, MO. 63101

PENTHOUSE - SURFACING

HMA LEGEND

SURFACING HMA - PENTHOUSE

JB-1-P-surfacing

J.RHYNEER

ONE

70 Residual exterior surfacing stucco - tan (beneath EIFS layer)

- 5692 ft²

AutoCAD SHX Text 4E01A

AutoCAD SHX Text 4E01

AutoCAD SHX Text

%%UEAST WING PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

%%UCENTER PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

%%UELEVATOR PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text 4W01

AutoCAD SHX Text 4C02B

AutoCAD SHX Text 4C02A

AutoCAD SHX Text 4C01

AutoCAD SHX Text 4C01B

AutoCAD SHX Text 4C01A

AutoCAD SHX Text 4C02

AutoCAD SHX Text 4C03

AutoCAD SHX Text 4C03A

DRAWING NO.

Project Title

Building Number

Location

Drawn

Checked

Drawing Title

V.A.M.C. ST. LOUIS, MO.

JEFFERSON BARRACKS DIVISION

ASBESTOS ASSESSMENT &

AREA LOCATION PROGRAM

V e t e r a n s

A d m i n i s t r a t i o n

U.S. GOVERNMENT PRINTING OFFICE: 1983-400-285

DateRevisions

VA FORM 08-6231, FEB. 1983

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A o n e e i g h t i n c e f o o t o n e q u a r t e r i n c e f o o t t h r e e e i g h t s i n c e f o o t t h r e e q u a r t e r s i n c e f o o t o n e i n c e f o o t o n e a n d o n e h a l f i n c h e e f o o t t h r e e i n c h e e f o o t o n e h a l f i n c e f o o t

F E

D C

B A

ASBESTOS CONTAINING TSI

GUIDE

XX HMA Numbers

XX

Sample Numbers

C.DEY

VA-JB 2018 Asbestos and

Lead Reinspection

SH1476

5-22-2019

Riverfront Safety & Health

1139 Olive St. Suite 300

St. Louis, MO. 63101

PENTHOUSE - TSI LOCATION

LEGEND

TSI LOCATION - PENTHOUSE

JB-1-P-TSI

J.RHYNEER

ONE

19 ACM pipe insulation and mudded fittings - 5 ft, 10 fittings

All asbestos pipe insulation is assumed to be in Good condition unless noted as Damaged (D) or Significantly Damaged (SD)

Unknown amounts of asbestos pipe insulation may be inside all inaccessible wet walls, pipe chases, perimeter steam chases, inside plaster walls, or above plaster ceilings

AutoCAD SHX Text 4E01A

AutoCAD SHX Text 4E01

AutoCAD SHX Text

%%UEAST WING PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

%%UCENTER PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

%%UELEVATOR PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text 4W01

AutoCAD SHX Text 4C02B

AutoCAD SHX Text 4C02A

AutoCAD SHX Text 4C01

AutoCAD SHX Text 4C01B

AutoCAD SHX Text 4C01A

AutoCAD SHX Text 4C02

AutoCAD SHX Text 4C03

AutoCAD SHX Text 4C03A

DRAWING NO.

Project Title

Building Number

Location

Drawn

Checked

Drawing Title

V.A.M.C. ST. LOUIS, MO.

JEFFERSON BARRACKS DIVISION

ASBESTOS ASSESSMENT &

AREA LOCATION PROGRAM

V e t e r a n s

A d m i n i s t r a t i o n

U.S. GOVERNMENT PRINTING OFFICE: 1983-400-285

DateRevisions

VA FORM 08-6231, FEB. 1983

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A o n e e i g h t i n c e f o o t o n e q u a r t e r i n c e f o o t t h r e e e i g h t s i n c e f o o t t h r e e q u a r t e r s i n c e f o o t o n e i n c e f o o t o n e a n d o n e h a l f i n c h e e f o o t t h r e e i n c h e e f o o t o n e h a l f i n c e f o o t

F E

D C

B A

XX HMA Numbers

XX

Sample Numbers

C.DEY

VA-JB 2018 Asbestos and

Lead Reinspection

SH1476

5-21-2019

Riverfront Safety & Health

1139 Olive St. Suite 300

St. Louis, MO. 63101

PENTHOUSE - SAMPLE

LOCATION LEGEND

SAMPLE LOCATION - PENTHOUSE

JB-1-P-sample

J.RHYNEER

ONE

AutoCAD SHX Text 4E01A

AutoCAD SHX Text 4E01

AutoCAD SHX Text

%%UEAST WING PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

%%UCENTER PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

%%UELEVATOR PENTHOUSE

AutoCAD SHX Text

%%UBLDG. 1

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text 4W01

AutoCAD SHX Text 4C02B

AutoCAD SHX Text 4C02A

AutoCAD SHX Text 4C01

AutoCAD SHX Text 4C01B

AutoCAD SHX Text 4C01A

AutoCAD SHX Text 4C02

AutoCAD SHX Text 4C03

AutoCAD SHX Text 4C03A

ST. LOUIS V.A. MEDICAL CENTER

JEFFERSON BARRACKS DIVISION

2018 REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Building 1 - Center - Penthouse

Room # Description Qty S/LF Fittings TH/DI 4C03-01-JB magnesia pipe lag 2 lf 0 4.00 4C03-01-JB mudded joint fittings on cardboard 0 ea 5 4.00

4C03A-01-JB magnesia pipe lag 3 lf 0 4.00 4C03A-01-JB mudded joint fittings on cardboard 0 ea 5 4.00

TOTALS 5 10

2018 Asbestos/Lead Inspection Report St. Louis Jefferson Barracks VAMC – Bldg. 1

SECTION 6.0

ASBESTOS CONTAINING MATERIAL CONDITION & REMOVAL

PRIORITY TABLE

WITH

ABATEMENT COST ESTIMATES

This section provides a table with the current condition, potential for disturbance, and removal priority for each ACM HMA.

Condition and Removal Priority Table

MANAGEMENT PLAN REMOVAL PRIORITY ASSESSMENT CHARTS

Qualitative (Descriptive) Rankings for Current Condition of ACM Qualitative Ranking Example Descriptions of Current Condition

Good (G) Surfacing material has no visible damage; covering on TSI is intact; miscellaneous materials are intact; no visible debris.

Damaged (D) Surfacing material has moderate but not extensive visible damage; covering on TSI is cut or torn, exposing small but not extensive amounts of insulation; miscellaneous materials have moderate but not extensive damage; moderate but not extensive amounts of visible debris

Significantly Damaged (SD) Extensive damage to surfacing material; covering on TSI is cut or torn extensively and insulation itself is damaged; miscellaneous materials such as floor tile is extensively damaged and underlying mastic exposed; extensive amounts of dust and debris.

Note: Damage is considered “extensive” when the total area of distributed damage exceeds 10%, or 25% localized damage.

Qualitative Rankings for Potential for Disturbance of ACM Level of Potential Disturbance Frequency of Potential

Contact (accessibility) Influence of Vibration Potential for Air Erosion or

Water Damage

HIGH (H)

(potential for significant damage) High Any Value Any Value

Any Value High Any Value Any Value Any Value High

MODERATE (M)

(potential for damage)

Moderate Moderate or Low Moderate or Low Moderate or Low Moderate Moderate or Low Moderate or Low Moderate or Low Moderate

LOW (L) Low Low Low Note: Overall rating determined by assigning disturbance probabilities under all 3 categories then adopting highest individual score for each material.

Qualitative Rankings and Numerical Ratings for Removal Priority of ACM Hazard Rank/

Removal Priority ACBM Condition ACBM Disturbance

Potential Recommended Response Actions

1 Significantly Damaged

Any Evacuate or isolate area immediately. Remove ACBM immediately. O&M Required for all friable ACBM.

2 Damaged High Evacuate or isolate area immediately. Remove, enclose, encapsulate or repair ACBM to correct immediately. Reduce potential for disturbance of remaining materials. O&M Required for all friable ACBM.

3 Damaged Moderate Remove, enclose, encapsulate, or repair to correct damage as soon as feasible.

O&M Required for all friable ACBM.

4 Damaged Low Remove, enclose, encapsulate, or repair to correct damage as needed to facilitate future projects. Take steps to reduce potential for disturbance. O&M Required for all friable ACBM.

5 Good High Take steps to reduce potential for disturbance. O&M Required for all friable ACBM.

6 Good Moderate O&M Required for all friable ACBM.

7 Good Low O&M Required for all friable ACBM, but measures need not be as extensive as

Category 6.

VA JEFFERSON BARRACKS CAMPUS

2018 ASBESTOS INSPECTION

CONDITION AND REMOVAL PRIORITY TABLE FOR

BUILDING 1

Homogeneous Area No. Bldg Floor Material Description

Friable Yes/No

Accessibility Yes/No

Restricted

Current Condition Potential for Disturbance Removal Priority

Rating Based On Rating Based On

Building 1 – Basement

HMA-A1 1 B 12"x12" floor tile – gray w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-B1 1 B 9"x9" floor tile - brown w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-C1 1 B 12”x12” floor tile - green w/ black mastic No Yes D Damaged M Floor Maintenance 3

HMA-D1 1 B 12"x12" floor tile - white w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-J1 1 B 9"x9" floor tile - gray w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-K1 1 B 9"x9" floor tile - dark brown w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-L1 1 B 9"x9" floor tile - tan w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-M1 1 B 9”x9” floor tile - dark grey w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-N1 1 B 12"x12" floor tile - brown w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-Q 1 B 12”x12” floor tile – light white No Yes G Intact L Floor Maintenance 7

HMA-1 1 B Black mastic No Yes G Intact L Floor Maintenance 7

HMA-19 1 B

ACM pipe insulation and mudded fittings (see maps for specific locations of severe damage)

Yes Yes SD Significantly Damaged M Access/

Maintenance 1

HMA-19 1 B

ACM pipe insulation and mudded fittings (see maps for locations of damage) Yes Yes D Damaged M Access/

Maintenance 3

HMA-19 1 B ACM pipe insulation and mudded fittings Yes G Intact M Access/Maintenance 6

HMA-24 1 B Fire Door No Restricted G Intact L Maintenance 7

HMA-25 1 B Interior window caulk-gray No Yes G Intact L Maintenance 7

Accessibility Yes/No

Restricted

Current Condition Potential for Disturbance Removal Priority

Rating Based On Rating Based On

HMA-29 1 B Penetration caulk-white No Yes G Intact L Maintenance 7

HMA-31 1 B Wall mounted heater (PACM) No Yes G Intact L Maintenance 7

HMA-41 1 B Flange gasket (PACM) No Yes G Intact L Maintenance 7

HMA-43 1 B Ceiling mounted heater (PACM) No Yes G Intact L Maintenance 7

HMA-46 1 B Thick gray caulk on AHU No No G Intact M Maintenance 6

HMA-71 1 B Transite panels No Yes G Intact L Access/ Maintenance 7

HMA-72 1 B 12”x12” floor tile- green w/ pattern w/black mastic No Yes D Damaged M Floor Maintenance 3

HMA-73 1 B Black mastic under 12”x12” floor tile-green/gray w/ splotches No Yes G Intact L Floor Maintenance 7

HMA-74 1 B Hard gray material on duct Yes No G Intact M Maintenance 6

HMA-75 1 B Felt roofing tar No Yes G Intact L Maintenance 7

Building 1 – 1st Floor

HMA-A1 1 1 12"x12" floor tile – gray w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-B1 1 1 9"x9" floor tile - brown w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-D1 1 1 12"x12" floor tile - white w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-J1 1 1 9"x9" floor tile - gray w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-N1 1 1 12"x12" floor tile - brown w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-Q1 1 1 12"x12" floor tile - light whit w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-R1 1 1 9”x9” floor tile – green w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-T1 1 1 12”x12” floor tile – light brown w/ black mastic No Yes G Intact L Floor Maintenance 7

Accessibility Yes/No

Restricted

Current Condition Potential for Disturbance Removal Priority

Rating Based On Rating Based On

HMA-19 1 1

ACM pipe insulation and mudded fittings (see maps for specific locations of severe damage)

Yes Yes SD Significantly Damaged M Access/

Maintenance 1

HMA-19 1 1

ACM pipe insulation and mudded fittings (see maps for locations of damage) Yes Yes D Damaged M Access/

Maintenance 3

HMA-19 1 1 ACM pipe insulation and mudded fittings Yes G Intact M Access/Maintenance 6

HMA-24 1 1 Fire Door No Restricted G Intact L Maintenance 7

HMA-31 1 1 Wall mounted heater (PACM) No Yes G Intact L Maintenance 7

HMA-41 1 1 Flange gasket (PACM) No Yes G Intact L Maintenance 7

HMA-43 1 1 Ceiling mounted heater (PACM) No Yes G Intact L Maintenance 7

Building 1 – 2nd Floor

HMA-D1 1 2 12"x12" floor tile - white w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-N1 1 2 12"x12" floor tile - brown w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-P1 1 2 Linoleum floor w/ black mastic Yes Yes G Intact L Floor Maintenance 7

HMA-Q1 1 2 12"x12" floor tile - light white w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-T1 1 2 12”x12” floor tile – light brown w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-W1 1 2 12”x12” floor tile – dark white w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-19 1 2

ACM pipe insulation and mudded fittings (see maps for specific locations of severe damage)

Yes Yes SD Significantly Damaged M Access/

Maintenance 1

HMA-19 1 2

ACM pipe insulation and mudded fittings (see maps for locations of damage) Yes Yes D Damaged M Access/

Maintenance 3

HMA-19 1 2 ACM pipe insulation and mudded fittings Yes G Intact M Access/Maintenance 6

HMA-24 1 2 Fire Door No Restricted G Intact L Maintenance 7

HMA-31 1 2 Wall mounted heater (PACM) No Yes G Intact L Maintenance 7

Accessibility Yes/No

Restricted

Current Condition Potential for Disturbance Removal Priority

Rating Based On Rating Based On

HMA-41 1 2 Flange gasket (PACM) No Yes G Intact L Maintenance 7

HMA-43 1 2 Ceiling mounted heater (PACM) No Yes G Intact L Maintenance 7

HMA-62 1 2 Black lab countertop No Yes G Intact L Maintenance 7

HMA-65 1 2 Transite vent hood No Yes G Intact L Maintenance 7

HMA-71 1 2 Transite panels No Yes G Intact L Access/ Maintenance 7

Building 1 – 3rd Floor

HMA-B1 1 3 9"x9" floor tile - brown w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-D1 1 3 12”x12” floor tile - white w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-P1 1 3 Linoleum floor w/ black mastic Yes Yes G Intact L Floor Maintenance 7

HMA-Q1 1 3 12"x12" floor tile - light white w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-T1 1 3 12”x12” floor tile – light brown w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-W 1 3 12”x12” floor tile – dark white No Yes G Intact L Floor Maintenance 7

HMA-19 1 3 ACM pipe insulation and mudded fittings Yes Yes G Intact M Access/

Maintenance 6

HMA-24 1 3 Fire Door No Restricted G Intact L Maintenance 7

HMA-25 1 3 Interior window caulk - gray No Yes G Intact L Maintenance 7

HMA-31 1 3 Wall mounted heater (PACM) No Yes G Intact L Maintenance 7

HMA-41 1 3 Flange gasket (PACM) No Yes G Intact L Maintenance 7

HMA-43 1 3 Ceiling mounted heater (PACM) No Yes G Intact L Maintenance 7

HMA-62 1 3 Black lab countertop No Yes G Intact L Maintenance 7

HMA-64 1 3 Black tar – covered duct insulation Yes No G Intact L Access/ Maintenance 7

Accessibility Yes/No

Restricted

Current Condition Potential for Disturbance Removal Priority

Rating Based On Rating Based On

HMA-65 1 3 Transite vent hood No Yes G Intact L Maintenance 7

Building 1 – Penthouse

HMA-D1 1 P 12"x12" floor tile – white w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-R1 1 P 9”x9” floor tile – green w/ black mastic No Yes G Intact L Floor Maintenance 7

HMA-19 1 P ACM pipe insulation and mudded fittings Yes Yes G Intact M Maintenance 6

HMA-24 1 P Fire door No Restricted G Intact L Maintenance 7

HMA-41 1 P Flange gasket (PACM) No Yes G Intact L Maintenance 7

Building 1 – Exterior

HMA-69 1 Ext Roofing mastic No No G Intact M Maintenance 6

HMA-70 1 Ext Stucco surfacing material-tan Yes Yes D Damaged M Maintenance 6

HMA-75 1 Ext Felt roofing tar No Yes G Intact M Maintenance 6

2018 Asbestos Summary and Cost Table VA-Jefferson Barracks Medical Facility Building 1

2018 BUILDING 1 ACM SUMMARY AND COST TABLE

ACM

DESCRIPTION FRIABLE? CONDITION EST.

QNTY.

UNIT

COST COST TO REMOVE

12"x12" floor tile – gray w/ black mastic

CAT 1 Non- Friable Good 9,950 ft2 $7/ft2 $69,650

9"x9" floor tile -brown w/ black mastic

CAT 1 Non- Friable Good 9,950 ft2 $7/ft2 $69,650

12"x12" floor tile -white w/ black mastic

CAT 1 Non- Friable Good 10,725 ft2

$7/ft2 $75,075

9"x9" floor tile - gray w/ black mastic

CAT 1 Non- Friable Good 2,250 ft2

$7/ft2 $15,750

9"x9" floor tile - dark brown w/ black mastic

CAT 1 Non- Friable Good 1,125 ft2

$7/ft2 $7,875

9"x9" floor tile - tan w/ black mastic

CAT 1 Non- Friable Good 450 ft2

$7/ft2 $3,150

12"x12" floor tile -brown w/ black mastic

Friable Good 1,450 ft2

$7/ft2 $10,150

12"x12" floor tile -light white w/ black mastic

Friable Good 25,500 ft2

$7/ft2 $178,500

9”x9” floor tile – dark gray w/ black mastic

Friable Good 225 ft2

$7/ft2 $1,575

12”x12” floor tile – green w/ black mastic

Friable Damaged 1,350 ft2

$7/ft2 $9,450 green w/ pattern w/ black mastic

Friable Damaged 1,350 ft2

$7/ft2 $9,450

9”x9” floor tile -green w/ black mastic

Friable Good 900 ft2

$7/ft2 $6,300 light brown w/ black mastic

Friable Good 9,900 ft2

$7/ft2 $69,300 dark white w/ black mastic

Friable Good 3,150 ft2

$7/ft2 $22,050

Linoleum floor w/ black mastic Friable Good 675 ft2

$7/ft2 $4,725

ACM pipe insulation and mudded fittings Friable Significantly

Damaged 9,915 ft, 3,066 fittings $25/ft $401,175

Fire Door (PACM) CAT 2 Non- Friable Good 26 Units $750/ea $19,500

2018 Asbestos Summary and Cost Table

Building 1

2018 BUILDING 1 ACM SUMMARY AND COST TABLE

ACM

DESCRIPTION FRIABLE? CONDITION EST.

QNTY.

UNIT

COST COST TO REMOVE

Wall mounted heater

(PACM)

CAT 2 Non- Friable Good 322 Units $500/ea $161,000

Flange gasket

(PACM)

CAT 1 Non- Friable Good TBD $500/ea TBD, Requires NESHAP

Inspection Ceiling mounted heater (PACM)

CAT 2 Non- Friable Good 38 units $500/ea $19,000

Black lab countertop CAT 2 Non- Friable Good 570 ft2 $22/ft2 $12,540

Transite vent hood CAT 2 Non- Friable Good 3 units $1,000/ ea $3,000

Interior window caulk-gray

CAT 1 Non- Friable Good 48 units $500/ea $24,000

Penetration caulk-white

CAT 1 Non- Friable Good 5 ft $200/ft $1,000

Thick gray caulk on

AHU

CAT 1 Non- Friable Good 30 ft $65/ft2 $1,950

Black mastic under 12”x12” floor tile-green/gray w/splotches

CAT 1 Non- Friable Good 1,575 ft2 $7/ft2 $11,025

Hard gray material on duct

CAT 2 Non- Friable Good 10 ft $100 $1,000

Stucco surfacing material-tan Friable Damaged 94,864 ft2 $30/ft2 $2,845,920

Roofing mastic CAT 1 Non- Friable Good 2,780 ft2 $10/ft2 $27,800

Felt roofing tar CAT 1 Non- Friable Good 267 ft2 $20/ft2 $5,340

Transite panels CAT 2 Non- Friable Good 2, 125 ft2 $10.50/ ft2 $22,312.50

SECTION 7.0

MASTER BULK SAMPLE SUMMARY TABLES

This table provides a listing of all asbestos bulk samples taken during the 2018 inspection.

2018 Asbestos Bulk Sample Table

Building 1

2018 ACM INSPECTION REPORT

VA JEFFERSON BARRACKS ST. LOUIS CAMPUS

BUILDING 1

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-00-M-

GC03-23

4x8 perforated panels cement asbestos board 00 GC03 Asbestos detected

JB-01-00-M-

GC10-57 2x2 gray pin & gouge ceiling tile 00 GC10A None detected

JB-01-00-M-

GC10A-53 4" black cove base 00 GC10A None detected

JB-01-00-M-

GC10A-54 2x2 gray worm & pin ceiling tile 00 GC10A None detected

JB-01-00-M-

GC17-09 Black condensate wrap 00 GC17 None detected

JB-01-00-M-

GC17-50 White gypsum drywall 00 GC17 None detected

JB-01-00-M-

GC17A-39 2x4 gray large & small pin ceiling tile 00 GC17A None detected

JB-01-00-M-

GC17A-40 2x4 gray pin pattern ceiling tile 00 GC17A None detected

JB-01-00-M-

GC17A-41

2x4 gray pin & jagged worm ceiling tile 00 GC17A None detected

JB-01-00-M-

GE01-26 Gray reflective paper 00 GE01 Asbestos detected

JB-01-00-M-

GE22-18 Brown speckled linoleum 00 GE22 Asbestos detected

JB-01-00-M-

GE26-01A Black other 00 GE26 None detected

JB-01-00-M-

GE29-25 2x2 gray worm & gouge ceiling tile 00 GE29 None detected

JB-01-00-M-

GE31-24 2x2 white w/pin pattern ceiling tile 00 GE31 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-00-M-

GE32-55

2x2 gray jagged worm & pin ceiling tile 00 GE32 None detected

JB-01-00-M-

GE32-56 6" black cove base 00 GE32 None detected

JB-01-00-M-

GW13-58 2x4 gray pin & gouge ceiling tile 00 GW13 None detected

JB-01-00-M-

GW13-61

2x4 gray pin & angle worms ceiling tile 00 GW13 None detected

JB-01-00-M-

GW14-62

2x4 gray random worm & gouge ceiling tile 00 GW14 None detected

JB-01-00-M-

H003-33 4" beige cove base 00 H003 None detected

JB-01-00-M-

H004-21 4" brown cove base 00 H004 None detected

JB-01-00-M-

H009-45 2" gray cove base 00 H009 None detected

JB-01-00-M-

H009-46 2x4 gray worm & pin ceiling tile 00 H009 None detected

JB-01-00-M-

H009-47

2x4 gray rough worm & pin ceiling tile 00 H009 None detected

JB-01-00-M-

S001-22 Beige stair tread 00 S001 None detected

JB-01-00-S-

GC17-15 Off-white hardwall plaster 00 GC17 None detected

JB-01-00-T-

GC02-37 Gray TSI 00 GC02 Asbestos detected

JB-01-00-T-

GC02-38 Gray TSI 00 GC02 None detected

JB-01-00-T-

GC17-13 Gray mudded joint fitting on tar wrap 00 GC17 None detected

JB-01-00-T-

GC17-14 Black/off-white tar wrap pipe lagging 00 GC17 None detected

JB-01-00-T-

GC17-51 Brown/off-white TSI 00 GC17 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-00-T-

GC17-52 Gray TSI 00 GC17 None detected

JB-01-00-T-

GC17A-10

Gray mudded joint fitting on cardboard lagging 00 GC17A Asbestos detected

JB-01-00-T-

GC17A-11 Brown cardboard wrap pipe lagging 00 GC17A None detected

JB-01-00-T-

GC18-07

Gray mudded joint fitting on magnesia pipe lagging 00 GC18 Asbestos detected

JB-01-00-T-

GC18-08 Off-white magnesia pipe lagging 00 GC18 Asbestos detected

JB-01-00-T-

GC18-12

Off-white mudded joint fitting on fiberglass 00 GC18 Asbestos detected

JB-01-00-T-

GC22-01 Gray tank #1 insulation 00 GC22 Asbestos detected

JB-01-00-T-

GC22-02 Amber/gray TSI 00 GC22 Asbestos detected

JB-01-00-T-

GC22-03 Amber/gray TSI 00 GC22 Asbestos detected

JB-01-00-T-

GC22-04 Gray tank #2 insulation 00 GC22 Asbestos detected

JB-01-00-T-

GC22-05 Gray TSI 00 GC22 Asbestos detected

JB-01-00-T-

GC22-06 Gray TSI 00 GC22 Asbestos detected

JB-01-00-T-

GE07-27 White canvas duct connector (woven) 00 GE07 Asbestos detected

JB-01-00-T-

GE07-28 Gray/off-white TSI 00 GE07 None detected

JB-01-00-T-

GE07-31 Gray TSI 00 GE07 Asbestos detected

JB-01-00-T-

GE07-32 Gray TSI 00 GE07 None detected

JB-01-00-T-

GE26-16 Gray aircell pipe lagging 00 GE26 Asbestos detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-00-T-

GE26-17

Gray mudded joint fitting on aircell lagging 00 GE26 Asbestos detected

JB-01-00-T-

GW03-42 White TSI 00 GW03 Asbestos detected

JB-01-00-T-

GW03-43 Gray TSI 00 GW03 Asbestos detected

JB-01-00-T-

GW03-44 White TSI 00 GW03 Asbestos detected

JB-01-00-T-

GW13-59 Brown TSI 00 GW13 None detected

JB-01-00-T-

GW13-60 White TSI 00 GW13 Asbestos detected

JB-01-00-T-

GW18-48 Gray TSI 00 GW18 None detected

JB-01-00-T-

GW18-49 Gray TSI 00 GW18 None detected

JB-01-00-T-

H001-29 Off-white/yellow TSI 00 H001 None detected

JB-01-00-T-

H001-30 White canvas duct insulation 00 H001 Asbestos detected

JB-01-00-T-

H003-34 Brown TSI 00 H003 None detected

JB-01-00-T-

H003-35 Gray TSI 00 H003 None detected

JB-01-00-T-

H003-36 Gray TSI 00 H003 None detected

JB-01-00-T-

H004-19 Off-white TSI 00 H004 Asbestos detected

JB-01-00-T-

H004-20 Gray TSI 00 H004 Asbestos detected

JB-01-01-

1W02-42

White mudded joint fitting on fiberglass lagging 01 1W02 Asbestos detected

JB-01-01-M-

1C102F-35 White ceiling tile 01 1C102F None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-01-M-

1C106-45

2x4 gray pin & jagged worm ceiling tile 01 1C106 None detected

JB-01-01-M-

1C115-20 2x4 gray worm & pin ceiling tile 01 1C115 None detected

JB-01-01-M-

1C123-22 Black ceiling tile mastic 01 1C123 None detected

JB-01-01-M-

1C125-01A Black other 01 1C125 None detected

JB-01-01-M-

1C125-26 White/brown gypsum drywall 01 1C125 None detected

JB-01-01-M-

1E07-34

2x2 gray rough worm & pin ceiling tile 01 1E07 None detected

JB-01-01-M-

1E17-44 2x2 gray worm & pin ceiling tile 01 1E17 None detected

JB-01-01-M-

1E17-46 2x2 gray jagged & pin ceiling tile 01 1E17 None detected

JB-01-01-M-

1E17-47 4" brown cove base 01 1E17 None detected

JB-01-01-M-

1E35-04 Gray reflective paper 01 1E35 Asbestos detected

JB-01-01-M-

1W08-18 2" brown cove base 01 1W08A None detected

JB-01-01-M-

1W08A-16 2" black cove base 01 1W08A None detected

JB-01-01-M-

1W11-25 1x1 off-white fissure ceiling tile 01 1W11 None detected

JB-01-01-M-

1W15-21 1x1 gray pin & peck ceiling tile 01 1W15 None detected

JB-01-01-M-

1W18-06 6" black cove base 01 1W18 None detected

JB-01-01-M-

1W20-15 2x2 gray random peck ceiling tile 01 1W20 None detected

1W24-27 Blue cove base 01 1W24 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-01-M-

1W26-17 1x1 off-white moon crater ceiling tile 01 1W26 None detected

JB-01-01-M-

H101-48 2x2 gray pin & gouge ceiling tile 01 H101 None detected

JB-01-01-M-

H102-03 2" gray cove base 01 H102 None detected

JB-01-01-M-

1E17-44

2x2 off-white worm & random gouge ceiling tile 01 H106 None detected

JB-01-01-M-

H106-43 4" gray cove base 01 H107 None detected

JB-01-01-M-

H107-29 4" gray cove base 01 H107 None detected

JB-01-01-M-

H107-30 2x2 off-white rough ceiling tile 01 H107 None detected

JB-01-01-M-

H112-24

2x4 gray rough worm & pin ceiling tile 01 H112 None detected

JB-01-01-M-

H116-13 2" beige cove base 01 H116 None detected

JB-01-01-M-

H117-19 4" beige cove base 01 H117 None detected

JB-01-01-M-

H119-14 2x4 gray pin & peck ceiling tile 01 H119 None detected

JB-01-01-M-

S101-05 Beige stair tread 01 S101 None detected

JB-01-01-M-

S101-28 4" black cove base 01 S101 None detected

JB-01-01-S-

1E05-36 White/gray hardwall plaster 01 1E05 None detected

JB-01-01-T-

1C105A-39 Black/yellow TSI 01 1C105A Asbestos detected

JB-01-01-T-

1E01-08 White TSI 01 1E01 Asbestos detected

JB-01-01-T-

1E01-10

Gray mudded joint fitting on magnesia pipe lagging 01 1E01 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-01-T-

1E05-31 White duct insulation 01 1E05 None detected

JB-01-01-T-

1E05-32 Gray TSI 01 1E05 None detected

JB-01-01-T-

1E05-40 White TSI 01 1E17 None detected

JB-01-01-T-

1E05-41 Off-white TSI 01 1E17 None detected

JB-01-01-T-

1E17-09 White TSI 01 1W02 Asbestos detected

JB-01-01-T-

1E17-12 Gray TSI 01 1W02 None detected

JB-01-01-T-

1W02-23 White canvas duct connector (woven) 01 1W20 Asbestos detected

JB-01-01-T-

1W02-33 Off-white/gray TSI 01 1W20 None detected

JB-01-01-T-

1W20-07 White magnesia pipe lagging 01 H101 Asbestos detected

JB-01-01-T-

1W20-11 Gray TSI 01 H101 None detected

JB-01-01-T-

H101-37

Black/brown mudded joint fitting on fiberglass 01 H105 Asbestos detected

JB-01-01-T-

H101-38 Black/yellow TSI 01 H105 Asbestos detected

JB-01-01-T-

H105-01 Black condensate wrap 02 2E04 None detected

JB-01-01-T-

H105-02 Brown canvas duct connector 02 2C04 None detected

JB-01-02-T-

2E04-16 Gray TSI 02 2C04 None detected

JB-01-02-M-

2C04-39 4" green cove base 01 1E17 None detected

JB-01-02-M-

2C04-40 4" olive cove base 01 1E17 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-02-M-

2C10-43 4'x8' white perforated panels 02 2C10 Asbestos detected

JB-01-02-M-

2C12-41 Black acoustical panels 02 2C12 None detected

JB-01-02-M-

2E05-38 2x4 gray giant worm & pin ceiling tile 02 2E05 None detected

JB-01-02-M-

2E17-30 2x4 gray pin pattern ceiling tile 02 2E17 None detected

JB-01-02-M-

2E18-34 2x2 gray pin & peck ceiling tile 02 2E18 None detected

JB-01-02-M-

2E20-29 Gray ceiling tile 02 2E20 None detected

JB-01-02-M-

2W15-47 4" brown cove base 02 2W15 None detected

JB-01-02-M-

2W22C-27 White/brown gypsum drywall 02 2W22C None detected

JB-01-02-M-

2W32-49 Gray ceiling tile 02 2W32 None detected

JB-01-02-M-

2W33-48 6" beige cove base 02 2W33 None detected

JB-01-02-M-

2E11-32 Gray ceiling tile 02 2E11 None detected

JB-01-02-M-

H201-28 2x2 gray worm & pin ceiling tile 02 H201 None detected

JB-01-02-M-

H202-35 4" gray cove base 02 H202 None detected

JB-01-02-M-

H203-31 2x2 off-white pin & gouge ceiling tile 02 H203 None detected

JB-01-02-M-

H203-33 Gray speckled linoleum 02 H203 None detected

JB-01-02-M-

H205-45 4" white cove base 02 H205 None detected

JB-01-02-M-

H205-46

2x2 gray random worm & gouge ceiling tile 02 H205 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-02-M-

S201-36 Beige stair tread 02 S201 None detected

JB-01-02-M-

S202-42 2" black cove base 02 S202 None detected

JB-01-02-S-

2W29-26 Off-white hardwall plaster 02 2W29 None detected

JB-01-02-T-

2C15-02 White TSI 02 2C15 Asbestos detected

JB-01-02-T-

2C15-05

White mudded joint fitting on magnesia lagging 02 2C15 Asbestos detected

JB-01-02-T-

2C15-08 Gray/black TSI 02 2C15 Asbestos detected

JB-01-02-T-

2C15-11 Gray/off-white TSI 02 2C15 None detected

JB-01-02-T-

2C18-17

White mudded joint fitting on fiberglass 02 2C18 Asbestos detected

JB-01-02-T-

2C18-20 Yellow/white TSI 02 2C18 None detected

JB-01-02-T-

2E04-19 White canvas duct insulation 02 2E04 None detected

JB-01-02-T-

2E29-03 White TSI 02 2E29 Asbestos detected

JB-01-02-T-

2E29-06 Gray TSI 02 2E29 None detected

JB-01-02-T-

2E29-12 Gray TSI 02 2E29 None detected

JB-01-02-T-

2W21-07

Gray/black cardboard wrap pipe lagging 02 2W21 Asbestos detected

JB-01-02-T-

2W21-10

Gray mudded joint fittings on cardboard 02 2W21 None detected

JB-01-02-T-

2W25-18 Gray TSI 02 2W25 Asbestos detected

JB-01-02-T-

2W25-21 Yellow/white TSI 02 2W25 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-02-T-

2W25-37 White canvas duct connector (woven) 02 2W25 None detected

JB-01-02-T-

2W29-01 White magnesia pipe lagging 02 2W29 Asbestos detected

JB-01-02-T-

2W29-04 Gray TSI 02 2W29 None detected

JB-01-02-T-

2W29-24 Black/yellow TSI 02 2W29 Asbestos detected

JB-01-02-T-

H209-22

Yellow/black tar mudded joint fitting on fiberglass 02 H209 Asbestos detected

JB-01-02-T-

H210-23 Black/yellow TSI 02 H210 Asbestos detected

JB-01-02-T-

S201-13 Brown/black TSI 02 S201 None detected

JB-01-02-T-

S201-14 Brown/black tar wrap pipe lagging 02 S201 Asbestos detected

JB-01-02-T-

S201-15 Brown/black TSI 02 S201 None detected

JB-01-2-M-

H205-44 4" beige cove base 02 H205 None detected

JB-02-02-T-

2E29-09 Gray TSI 02 2E29 Asbestos detected

JB-01-02-M-

2E27-25 4" black cove base 02 2E27 None detected

JB-01-03-M-

3C09-41 4" brown cove base 03 3C09 None detected

JB-01-03-M-

3C11-40 2" black cove base 03 3C11 None detected

JB-01-03-M-

3C26-44 2x4 gray worm & pin ceiling tile 03 3C26 None detected

JB-01-03-M-

3E05-28 4" black cove base 03 3E05 None detected

JB-01-03-M-

3E06A-27

2x4 gray pin & angle worms ceiling tile 03 3E06A None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-03-M-

3E09-29 2x4 gray pin & gouge ceiling tile 03 3E09 None detected

JB-01-03-M-

3E09-30 4" gray cove base 03 3E09 None detected

JB-01-03-M-

E311-26 Off-white gypsum drywall 03 E311 None detected

JB-01-03-M-

E311-33 2x4 gray pin & peck ceiling tile 03 E311 None detected

JB-01-03-M-

E313-34 4" light gray cove base 03 E313 None detected

JB-01-03-M-

H301-36

2x2 gray random worm & gouge ceiling tile 03 H301 None detected

JB-01-03-M-

H301-37 2x2 gray pin & gouge ceiling tile 03 H301 None detected

JB-01-03-M-

H301-38

2x2 gray rough worm & pin ceiling tile 03 H301 None detected

JB-01-03-M-

H303-39 2x2 gray worm & pin ceiling tile 03 H303 None detected

JB-01-03-M-

H303-42 2x2 gray pin & peck ceiling tile 03 H303 None detected

JB-01-03-M-

H304-43 Off-white cove base 03 H304 None detected

JB-01-03-M-

W314-01A Black rubberized duct connector 03 W314 None detected

JB-01-03-M-

W314-45 Gray other 03 W314 Asbestos detected

JB-01-03-T-

3C04-19

Gray/white cardboard wrap pipe lagging 03 3C04 Asbestos detected

JB-01-03-T-

3C04-22

White mudded joint fitting on cardboard lagging 03 3C04 Asbestos detected

JB-01-03-T-

3C12-13 White magnesia pipe lagging 03 3C12 Asbestos detected

JB-01-03-T-

3C13-14 White TSI 03 3C13 Asbestos detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-03-T-

3C13-15 White TSI 03 3C13 Asbestos detected

JB-01-03-T-

3C13-16

Gray mudded joint fitting on magnesia pipe lagging 03 3C13 None detected

JB-01-03-T-

3C13-17 Gray TSI 03 3C13 None detected

JB-01-03-T-

3C13-18 Gray TSI 03 3C13 None detected

JB-01-03-T-

3C14-20 Gray TSI 03 3C14 Asbestos detected

JB-01-03-T-

3C14-23 Gray TSI 03 3C14 None detected

JB-01-03-T-

3C18-21 Gray TSI 03 3C18 Asbestos detected

JB-01-03-T-

3C18-24 Gray TSI 03 3C18 None detected

JB-01-03-T-

3E03-10

Black/orange tar on fiberglass duct insulation 03 3E03 Asbestos detected

JB-01-03-T-

3E06-02 Black/yellow TSI 03 3E06 Asbestos detected

JB-01-03-T-

3E11-04 White canvas duct insulation 03 3E11 None detected

JB-01-03-T-

3E11-05 Green/white TSI 03 3E11 None detected

JB-01-03-T-

3E11-06 White/gray TSI 03 3E11 None detected

JB-01-03-T-

3E11-07

White mudded joint fitting on fiberglass 03 3E11 Asbestos detected

JB-01-03-T-

3E11-08 White TSI 03 3E11 Asbestos detected

JB-01-03-T-

3E11-09 White TSI 03 3E11 Asbestos detected

JB-01-03-T-

3E11-31 Gray TSI 03 3E11 Asbestos detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-03-T-

H302-11 Black/orange TSI 03 H302 Asbestos detected

JB-01-03-T-

H302-12 Black/yellow TSI 03 H302 Asbestos detected

JB-01-03-T-

H302-35

Gray/orange mud patch on fiberglass duct insulation 03 H302 Asbestos detected

JB-01-03-T-

H304-01

Black/yellow tar mudded joint fitting on fiberglass 03 H304 Asbestos detected

JB-01-03-T-

H305-03 Black/yellow TSI 03 H305 Asbestos detected

JB-03-S-

3E12-25 White/off-white hardwall plaster 03 3E12 None detected

JB-01-04-M-

4C02B-01A Black rubberized duct connector 04 4C02B None detected

JB-01-04-M-

4E01B-19 Black tar covering 04 4E01B Asbestos detected

JB-01-04-M-

S402-14 White gypsum drywall 04 S402 None detected

JB-01-04-S-

4C03-13 Off-white hardwall plaster 04 4C03A None detected

JB-01-04-T-

4C02-04

Off-white mudded joint fitting on fiberglass lagging 04 4C02 Asbestos detected

JB-01-04-T-

4C02-05 White TSI 04 4C02 Asbestos detected

JB-01-04-T-

4C02-06 White unknown 04 4C02 Asbestos detected

JB-01-04-T-

4C02-07 White canvas duct insulation 04 4C02 Asbestos detected

JB-01-04-T-

4C02-08 White/gray TSI 04 4C02 None detected

JB-01-04-T-

4C02-09 Yellow/white TSI 04 4C02 None detected

JB-01-04-T-

4C02-15 White canvas duct connector (woven) 04 4C02 Asbestos detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-04-T-

4C02-17 Green canvas duct connector 04 4C02 None detected

JB-01-04-T-

4C02-18 Brown canvas duct connector 04 4C02 None detected

JB-01-04-T-

4C03A-01 White magnesia pipe lagging 04 4C03A Asbestos detected

JB-01-04-T-

4C03A-02 White TSI 04 4C03A Asbestos detected

JB-01-04-T-

4C03A-03 White TSI 04 4C03A Asbestos detected

JB-01-04-T-

4E01B-10

White/orange debris from thermal insulation 04 4E01B Asbestos detected

JB-01-04-T-

4E01B-11 White TSI 04 4E01B Asbestos detected

JB-01-04-T-

4E01B-12 Gray TSI 04 4E01B Asbestos detected

JB-01-04-T-

4W01-16

Lightweight white canvas duct connector 04 4W01 None detected

JB-01-00-F-

GW13-001A Gray 12x12 floor tile, black mastic 00 GW13 6% Chrysotile, 19% Chrysotile in mastic

JB-01-00-S-

GW13-002A Gray transite peg board wall panel 00 GW13 19% Chrysotile

JB-01-00-F-

GW15-003A Gray 12x12 floor tile, black mastic 00 GW15 6% Chrysotile, 19% Chrysotile in mastic

JB-01-00-F-

GW17-004A Layer 1-brown 9x9 floor tile 00 GW17 19% Chrysotile

JB-01-00-F-

GW17-004A Layer 2-black mastic 00 GW17 None detected

JB-01-00-F-

GW02-005A Layer 1-brown 9x9 floor tile 00 GW02 19% Chrysotile

JB-01-00-F-

GW02-005A Layer 2-black mastic 00 GW02 None detected

JB-01-00-F-

GW01-006A Layer 2-black mastic 00 GW01 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-00-F-

GW10A-007A Gray 12x12 floor tile, black mastic 00 GW10A 9% Chrysotile

JB-01-00-M-

GW03-008A White vibration isolator 00 GW03 22% Chrysotile

JB-01-00-T-

GW03-009A White TSI wrapping on duct 00 GW03 None detected

JB-01-00-F-

GW04B-010A Green 12x12 floor tile, black mastic 00 GW04B 8% Chrysotile, 9% Chrysotile in mastic

JB-01-00-F-

H010-011A White 12x12 floor tile, black mastic 00 H010 None detected

JB-01-00-F-

GC17A-012A Layer 1-dark white 9x9 floor tile 00 GC17A 9% Chrysotile

JB-01-00-F-

GC17A-012A Layer 2-black mastic 00 GC17A None detected

JB-01-00-F-

GC17C-013A Layer 1-brown 9x9 floor tile 00 GC17C 19% Chrysotile

JB-01-00-F-

GC17C-013A Layer 2-black mastic 00 GC17C None detected

JB-01-00-F-

GC17-014A

Tan 12x12 floor tile, yellow mastic, black mastic 00 GC17 None detected

JB-01-00-F-

GC17-015A Layer 1-brown 9x9 floor tile 00 GC17 19% Chrysotile

JB-01-00-F-

GC17-015A Layer 2-black mastic 00 GC17 None detected

JB-01-00-F-

GC01-016A

Light gray 12x12 floor tile, yellow mastic, black mastic 00 GC01 None detected

JB-01-00-F-

GC02-017A Black felt, black mastic 00 GC02 None detected

JB-01-00-M-

GC01-018A White vibration isolator 00 GC01 75% Chrysotile

JB-01-00-M-

GC01-019A White vibration isolator 00 GC01 58% Chrysotile

GC03-020A Gray 12x12 floor tile, black mastic 00 GC03 6% Chrysotile, 12% Chrysotile in mastic

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-00-F-

H006-021A

White 12x12 floor tile, yellow mastic, black mastic 00 H006 None detected

JB-01-00-F-

H006-022A White 12x12 floor tile, black mastic 00 H006 None detected

JB-01-00-F-

GC14-023A Layer 1-gray 9x9 floor tile 00 GC14 19% Chrysotile

JB-01-00-F-

GC14-023A Layer 2-black mastic 00 GC14 None detected

JB-01-00-F-

GC15-024A

Dark brown 9x9 floor tile, black mastic 00 GC15 9% Chrysotile, 9% Chrysotile in mastic

JB-01-00-F-

GC15-025A Tan 9x9 floor tile, black mastic 00 GC15 9% Chrysotile, 9% Chrysotile in mastic

JB-01-00-F-

GC12-026A White 12x12 floor tile, black mastic 00 GC12 None detected

JB-01-00-F-

GC12-027A Layer 1-dark gray 9x9 floor tile 00 GC12 19% Chrysotile

JB-01-00-F-

GC12-027A Layer 2-black mastic 00 GC12 None detected

JB-01-00-F-

GC11-028A Layer 1-white 12x12 floor tile 00 GC11 None detected

JB-01-00-F-

GC11-028A Layer 2-black mastic 00 GC11 9% Chrysotile

JB-01-00-F-

GC11-028A Layer 3-yellow mastic 00 GC11 None detected

JB-01-00-F-

GC09-029A Layer 1-brown 12x12 floor tile 00 GC09 None detected

JB-01-00-F-

GC09-029A Layer 2-black mastic 00 GC09 12% Chrysotile

JB-01-00-F-

GE19-030A Layer 1-brown 12x12 floor tile 00 GE19 None detected

JB-01-00-F-

GE19-030A Layer 2-black mastic 00 GE19 19% Chrysotile

H004-031A Layer 1-brown 12x12 floor tile 00 H004 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-00-F-

H004-031A Layer 2-black mastic 00 H004 12% Chrysotile

JB-01-00-S-

GE18C-032A Tan textured material 00 GE18C 9% Chrysotile

JB-01-00-M-

GE18-033A Felt, roofing tar 00 GE18 9% Chrysotile

JB-01-00-F-

GE04-034A Layer 1-brown 9x9 floor tile 00 GE04 19% Chrysotile

JB-01-00-F-

GE04-034A Layer 2-black mastic 00 GE04 None detected

JB-01-00-F-

GE05-035A Black mastic 00 GE05 None detected

JB-01-00-F-

GE09-036A Layer 1-dark brown 9x9 floor tile 00 GE09 12% Chrysotile

JB-01-00-F-

GE09-036A Layer 2-black mastic 00 GE09 None detected

JB-01-00-F-

GE10-037A Tan 12x12 floor tile, yellow mastic 00 GE10 None detected

JB-01-00-T-

H001-038A

6" horizontal-white wrap, foil backing, yellow fiberglass pipe insulation 00 H001 None detected

JB-01-00-T-

H001-039A

6" horizontal pipe hanger-white wrap, foil backing, yellow fiberglass pipe insulation 00 H001 15% Chrysotile

JB-01-00-F-

GC17E-040A Layer 1-dark white 9x9 floor tile 00 GC17 6% Chrysotile

JB-01-00-F-

GC17E-040A Layer 2-black mastic 00 GC17 None detected

JB-01-00-F-

GW09-041A Layer 1-light white 12x12 floor tile 00 GW09 None detected

JB-01-00-F-

GW09-041A Layer 2-yellow mastic 00 GW09 None detected

JB-01-00-F-

GW09-041A Layer 3-brown 9x9 floor tile 00 GW09 19% Chrysotile

GW09-041A Layer 4-black mastic 00 GW09 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-00-F-

GW08A-

042A Layer 1-light white 12x12 floor tile 00 GW08A None detected

JB-01-00-F-

GW08A-

042A Layer 2-yellow mastic 00 GW08A None detected

JB-01-00-F-

GW08A-

042A Layer 3-brown 9x9 floor tile 00 GW08A None detected

JB-01-00-F-

GW08A-

042A Layer 4-black mastic 00 GW08A 9% Chrysotile

JB-01-00-F-

GW04-043A Layer 1-green 12x12 floor tile 00 GW04 6% Chrysotile

JB-01-00-F-

GW04-043A Layer 2-yellow mastic 00 GW04 None detected

JB-01-00-F-

GW05A-

044A Layer 1-light white 12x12 floor tile 00 GW05A None detected

JB-01-00-F-

GW05A-

044A Layer 2-yellow mastic 00 GW05A None detected

JB-01-00-F-

GW05A-

044A Layer 3-green 12x12 floor tile 00 GW05A 6% Chrysotile

JB-01-00-F-

GW05A-

044A Layer 4-black mastic 00 GW05A 9% Chrysotile

JB-01-01-F-

1E21-045A Layer 1-light white 12x12 floor tile 01 1E21 None detected

JB-01-01-F-

1E21-045A Layer 2-yellow mastic 01 1E21 None detected

JB-01-01-F-

1E21-045A Layer 3-green 9x9 floor tile 01 1E21 19% Chrysotile

JB-01-01-F-

1E21-045A Layer 4-black mastic 01 1E21 None detected

JB-01-01-F-

1E34-046A Layer 1-brown 9x9 floor tile 01 1E34 19% Chrysotile

JB-01-00-F-

GW05A-

044A Layer 1-light white 12x12 floor tile 00 GW05A None detected

JB-01-00-F-

GW05A-

044A Layer 2-yellow mastic 00 GW05A None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-01-F-

1E34-046A Layer 2-black mastic 01 1E34 None detected

JB-01-01-F-

1E39A-047A Tan 12x12 floor tile, black mastic 01 1E39A None detected

JB-01-01-M-

1E39-048A Black lab countertop 01 1E39 None detected

JB-01-01-T-

H105-049A

10" horizontal-white wrap, foil backing, white block insulation 01 H105 12% Amosite, 12% Chrysotile

JB-01-01-F-

H105-050A Green 9x9 floor tile, black mastic 01 H105 9% Chrysotile, 9% Chrysotile in mastic

JB-01-01-F-

1E38-051A Layer 1-light white 12x12 floor tile 01 1E38 None detected

JB-01-01-F-

1E38-051A Layer 2-yellow mastic 01 1E38 None detected

JB-01-01-F-

1E38-051A Layer 3-brown 9x9 floor tile 01 1E38 19% Chrysotile

JB-01-01-F-

1E38-051A Layer 4-black mastic 01 1E38 None detected

JB-01-01-F-

H102-052A Layer 1-green 9x9 floor tile 01 H102 19% Chrysotile

JB-01-01-F-

H102-052A Layer 2-black mastic 01 H102 None detected

JB-01-01-F-

1E33-053A

Dark gray 12x12 floor tile, yellow mastic, black mastic 01 1E33 None detected

JB-01-01-F-

H103-054A Layer 1-dark white 9x9 floor tile 01 H103 19% Chrysotile

JB-01-01-F-

H103-055A Layer 1-tan 12x12 floor tile 01 H103 12% Chrysotile

JB-01-01-F-

H103-055A Layer 2-black mastic 01 H103 None detected

JB-01-01-F-

1E07-056A Brown 12x12 floor tile, yellow mastic 01 1E07 None detected

1E05-057A White vibration isolator 01 1E05 58% Chrysotile

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-01-F-

1E17A-058A

Light white 12x12 floor tile, yellow mastic 01 1E17A None detected

JB-01-01-F-

1E02-059A

Brown 12x12 floor tile, yellow mastic, black mastic 01 1E02 None detected

JB-01-01-F-

1E01A-060A Layer 1-brown 12x12 floor tile 01 1E01A None detected

JB-01-01-F-

1E01A-060A Layer 2-yellow mastic 01 1E01A None detected

JB-01-01-F-

1E01A-060A Layer 3-dark white 9x9 floor tile 01 1E01A 19% Chrysotile

JB-01-01-F-

1E01A-060A Layer 4-black mastic 01 1E01A None detected

JB-01-01-F-

H104-061A Layer 1-white 12x12 floor tile 01 H104 None detected

JB-01-01-F-

H104-061A Layer 2-yellow mastic 01 H104 None detected

JB-01-01-F-

H104-061A Layer 3-light white 12x12 floor tile 01 H104 6% Chrysotile

JB-01-01-F-

H104-061A Layer 4-black mastic 01 H104 None detected

JB-01-01-F-

1C121A-062A Gray 12x12 floor tile, black mastic 01 1C121A None detected

JB-01-01-F-

1C102-063A Gray 12x12 floor tile, black mastic 01 1C102 None detected

JB-01-01-F-

1C104-064A Gray 12x12 floor tile 01 1C104 None detected

JB-01-01-F-

H116-065A

White 12x12 floor tile, yellow mastic, light white 12x12 floor tile, yellow mastic, black mastic 01 H116 None detected

JB-01-01-T-

H119-066A Layer 1-6" elbow black mastic 01 H119 29% Chrysotile

JB-01-01-T-

H119-066A

Layer 2-brown wrap fiberglass insulation 01 H119 None detected

JB-01-01-T-

H119-067A 6" horizontal-gray TSI insulation 01 H119 26% Amosite

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-01-T-

H119-068A Layer 1-4" elbow-black mastic 01 H119 29% Chrysotile

JB-01-01-T-

H119-068A

Layer 2-brown wrap fiberglass insulation, foil backing 01 H119 None detected

JB-01-01-T-

H119-069A

Layer 1-4" horizontal-brown wrap, foil backing 01 H119 None detected

JB-01-01-T-

H119-069A Layer 2-gray TSI 01 H119 29% Amosite

JB-01-01-F-

H119-070A Layer 1-white 12x12 floor tile 01 H119 None detected

JB-01-01-F-

H119-070A Layer 2-yellow mastic 01 H119 None detected

JB-01-01-F-

H119-070A Layer 3-light brown 12x12 floor tile 01 H119 6% Chrysotile

JB-01-01-F-

H119-070A Layer 4-black mastic 01 H119 None detected

JB-01-01-F-

1W01-071A Layer 1-light white 12x12 floor tile 01 1W01 6% Chrysotile

JB-01-01-F-

1W01-071A Layer 2-black mastic 01 1W01 None detected

JB-01-01-F-

1W05-072A Layer 1-brown 12x12 floor tile 01 1W05 6% Chrysotile

JB-01-01-F-

1W05-072A Layer 2-yellow mastic 01 1W05 None detected

JB-01-01-F-

1W05-072A Layer 3-black mastic 01 1W05 9% Chrysotile

JB-01-01-F-

1W26-073A Layer 1-light white 12x12 floor tile 01 1W26 None detected

JB-01-01-F-

1W26-073A Layer 2-yellow mastic 01 1W26 None detected

JB-01-01-F-

1W26-073A Layer 3-gray 9x9 floor tile 01 1W26 12% Chrysotile

JB-01-01-F-

1W26-073A Layer 4-black mastic 01 1W26 None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-01-F-

1W23-074A Layer 1-adhesive, gray 9x9 floor tile 01 1W23 19% Chrysotile

JB-01-01-F-

1W23-074A Layer 2-black mastic 01 1W23 None detected

JB-01-01-F-

H117-075A Layer 1-white 12x12 floor tile 01 H117 None detected

JB-01-01-F-

H117-075A Layer 2-yellow mastic 01 H117 None detected

JB-01-01-F-

H117-075A

Layer 3-brown 9x9 floor tile, black mastic 01 H117 19% Chrysotile

JB-01-01-F-

H117-075A Layer 4-black mastic 01 H117 None detected

JB-01-02-F-

2E04-076A Brown 9x9 floor tile, black mastic 02 2E04 6% Chrysotile, 9% Chrysotile in mastic

JB-01-02-F-

2E04-077A Layer 1-dark brown 9x9 floor tile 02 2E04 12% Chrysotile

JB-01-02-F-

2E04-077A Layer 2-black mastic 02 2E04 None detected

JB-01-02-M-

2E04-078A White vibration isolator 02 2E04 54% Chrysotile

JB-01-02-T-

2E04-079A

6" elbow-white wrap, white block insulation 02 2E04 23% Chrysotile

JB-01-02-T-

2E04-080A

6" horizontal-white wrap, foil backing, yellow fiberglass insulation 02 2E04 None detected

JB-01-02-T-

2E04-081A

2" elbow-white wrap, white block insulation 02 2E04 25% Chrysotile

JB-01-02-T-

2E04-082A

2" horizontal-white wrap, white block insulation 02 2E04 25% Chrysotile

JB-01-02-F-

H201-083A Layer 1-gray linoleum 02 H201 20% Chrysotile

JB-01-02-F-

H201-083A Layer 2-yellow mastic 02 H201 None detected

JB-01-02-F-

2E07A-084A Layer 1-white 12x12 floor tile 02 2E07A None detected

Building 1

Historical Asbestos Bulk Sampling Summary

Sample No. HMA Number and Material Description Floor Room Asbestos Content

JB-01-02-F-

2E07A-084A Layer 2-black mastic 02 2E07A 8% Chrysotile

JB-01-02-F-

2E15-085A Layer 1-gray linoleum 02 2E15 20% Chrysotile

JB-01-02-F-

2E15-085A Layer 2-black mastic 02 2E15 None detected

JB-01-02-F-

2E19-086A Layer 1-light white 12x12 floor tile 02 2E19 None detected

JB-01-02-F-

2E19-086A Layer 2-yellow mastic 02 2E19 None detected

JB-01-02-F-

2E19-086A Layer 3-black mastic 02 2E19 9% Chrysotile

JB-01-02-F-

H203-087A Layer 1-gray linoleum 02 H203 None detected

JB-01-02-F-

H203-087A Layer 2-yellow mastic 02 H203 None detected

JB-01-02-F-

H203-087A Layer 3-black mastic 02 H203 9% Chrysotile

JB-01-02-F-

2W13-088A Layer 1-white 12x12 floor tile 02 2W13 None detected

JB-01-02-F-

2W13-088A Layer 2-yellow mastic 02 2W13 None detected

JB-01-02-F-

2W13-088A Layer 3-black mastic 02 2W13 9% Chrysotile

JB-01-02-F-

2W06-089A Layer 1-brown linoleum 02 2W06 20% Chrysotile

JB-01-02-F-

2W06-089A Layer 2-black mastic 02 2W06 None detected

JB-01-02-F-

2W22C-090A Layer 1-brown linoleum 02 2W22C 20% Chrysotile

JB-01-02-F-

2W22C-090A Layer 2-black mastic 02 2W22C None detected

H208-091A Layer 1-light white…