6-0.2 Plans.pdf
PDF 38 MB Posted
- Attached to
- Construction of Fire Station 2
- Solicitation number
- 2026-14
- Issued by
- Seminole County, Florida
About this file
This is a 100% construction document set for Fire Station 2 in McAlpin, Florida, prepared by Donnelly Architecture, Incorporated for the Suwannee County Board of County Commissioners. The project involves the construction of a new 7,294 square foot steel frame fire station building with associated site development on a 11,572 CR 252 McAlpin, Florida location. The construction documents include architectural, structural, mechanical, electrical, and plumbing plans with detailed specifications for all building systems, finishes, and site work. The project scope encompasses grading and drainage, asphalt pavement, concrete flatwork, concrete curbing and sidewalks, underground utilities, stormwater retention, final site dressing, and demolition of existing infrastructure. The building is classified as mixed occupancy containing residential (R-2) space for 16 occupants and storage (S-2) space, with a total occupant load of approximately 30 persons. The facility includes fireman's quarters, officer's quarters, mechanical room, domestic laundry, recreation/workout room, shower rooms, kitchen, dining area, gear storage, apparatus bay, and administrative office space. The construction documents are dated July 20, 2026 and represent 100% design completion.
The project is designed to comply with Florida Building Code, Eighth Edition (2023), Florida Fire Prevention Code, Eighth Edition (2021), and the 2020 National Electric Code. The facility incorporates fire-rated wall assemblies using 1-hour UL-419 rated construction with gypsum board on metal stud framing, NFPA 13R sprinkler system, NFPA 72 fire alarm system, and impact-resistant openings per Florida Product Approval standards. The building features a standing seam metal roof system, stone veneer exterior cladding on concrete masonry unit substrate, concrete slab-on-grade flooring with decorative epoxy finish in mechanical areas, and interior finishes including lay-in acoustical ceilings, gypsum drywall with paint, ceramic tile in wet areas, and rubber base molding. The structural design is Type II (0,0,0) fire-resistant construction suitable for three stories with allowable heights up to 60 feet. All materials specified are new, and the contractor is responsible for obtaining necessary permits, conducting utility locates, performing material testing, and providing operation and maintenance manuals. Donnelly Architecture, with offices in Gainesville and Crystal River, Florida, serves as the architect, with Devlen Engineering, Inc. as structural engineer and Joseph, Lawrence & Co., LLC as MEP engineer.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 7-1.4 Schedule, Approach, and Subcontractor-Suppliers.pdf | ||
| 2-0.1 Instructions.pdf | ||
| 8-0.4 Schedule and Approach.pdf | ||
| 4-0.0 Advertisement.jpg | JPG image | |
| 9-1.5 Time Allocation Ack.pdf | ||
| 11-0.5 Standard Conditions Construction Contract.pdf | ||
| 3-1.1 Summary Form.pdf | ||
| 1-1.3 Required Forms.pdf | ||
| 10-1.2 Bid Schedule (BT-18DF).xlsx | XLSX spreadsheet | |
| 5-0.3 Geotechnical Report.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COVER SHEET
A0.00
SHEET INDEX
MCALPIN, FLORIDA
SUWANNEE COUNTY FIRE RESCUE
CONSTRUCTION DOCUMENTS
SU
W
A N
N
EE
C O
U N
T Y
FI
R
E R
ES
C
U E
M cA lp in
, F lo rid a
FLORIDA ARCHITECT AR 92950
FI
R
E
ST
A T
IO
N
PROJECT LOCATION:
SUWANEE FIRE STATION 2
11572 CR 252
MCALPIN, FLORIDA
Do nn el ly
P ro je ct
352.249.1166
WWW.DONNELLYARCHITECTURE.COM
Architecture,Donnelly IncorporatedAR92950
825 NW 13TH STREET
GAINESVILLE, FLORIDA 32601
1384 NORTH CITRUS AVENUE
CRYSTAL RIVER, FLORIDA 34428
JULY 20, 2026
100% CONSTRUCTION
DOCUMENTS
AND CONTENTS
FIRE STATION 2
CREATION OF A NEW FIRE STATION
IN MCALPIN, FLORIDA
PROJECT LOCATION: PROJECT DESCRIPTION:
A0.00 COVER SHEET AND CONTENTS
A0.01 LIFE SAFETY PLAN, CODE SUMMARY
A0.02 RATED ASSEMBLIES
A0.05 GENERAL NOTES AND LEGENDS
A0.07 ARCHITECTURAL SITE PLAN
A0.10 OVERALL FLOOR PLAN
A0.20 EXTERIOR ELEVATIONS
A0.25 BUILDING SECTIONS
A0.30 EXTERIOR OPENING TYPES AND NOTES
A0.35 EXTERIOR OPENING DETAILS
A0.40 ROOF PLAN AND NOTES
A1.01 FLOOR PLAN AND NOTES
A1.05 DIMENSION FLOOR PLAN AND NOTES
A1.10 ENLARGED FLOOR PLANS AND NOTES
A1.21 REFLECTED CEILING PLAN AND NOTES
A1.50 FINISHES SPECIFICATIONS
A1.51 FINISHES FLOOR PLAN AND NOTES
A3.00 INTERIOR OPENING TYPES AND NOTES
A4.00 INTERIOR ELEVATIONS
A4.05 INTERIOR DETAILS
A4.10 INTERIOR WALL TYPES
C0.10 GENERAL NOTES
C0.20 EXISTING CONDITIONS AND DEMOLITION PLAN
C1.00 SITE GEOMETRY AND MARKING PLAN
C2.00 PAVING GRADING AND DRAINAGE PLAN
C2.01 BASIN AND GRADING PROFILES
C2.30 SWPP PLAN
C2.31 SWPP NOTES
C2.32 SWPP CERTIFICATIONS
C2.40 TEMPORARY TRAFFIC CONTROL PLAN
C3.00 UTILITIES PLAN
C4.00 CONSTRUCTION DETAILS
LS-1 LANDSCAPE PLAN
1 OF 1 TOPOGRAPHIC SURVEY
S-1.1 GENERAL STRUCTURAL NOTES
S-1.2 GENERAL STRUCTURAL NOTES
S-2.1 FOUNDATION PLAN
S-2.2 TOP OF WALL FRAMING PLAN
S-2.3 WALL SECTIONS
S-3.1 FOUNDATION DETAILS
S-3.2 MASONRY DETAILS
E0.01 ABBREV. LEGEND & GENERAL NOTES
E1.01 SITE PLAN POWER & SYSTEMS
E1.02 SITE SLAB LIGHTING
E1.03 SITE PLAN PHOTOMETRICS
E1.04 SITE FIXTURE CUTSHEETS
E2.01 FLOOR PLAN POWER & SYSTEMS
E3.01 FLOOR PLAN LIGHTING
E4.01 POWER RISER DIAGRAM
E4.02 FIRE ALARM RISER DIAGRAM
E5.01 SCHEDULES
E6.01 DETAILS
E7.01 DETAILS
M0.01 SYMBOL LEGEND & GENERAL NOTES
M2.01 FLOOR PLAN
M3.01 SCHEDULES
M4.01 DETAILS
M4.02 DETAILS
M5.01 CONTROLS DIAGRAMS
M6.01 ENERGY COMPLIANCE
M7.01 SPECIFICATIONS
P0.01 SYMBOL LEGEND & GENERAL NOTES
P2.01 FLOOR PLAN
P2.02 FLOOR PLAN
P3.01 SANITARY RISER DIAGRAM
P3.02 WATER RISER DIAGRAM
P4.01 SCHEDULES
P5.01 DETAILS
OWNER:
SUWANNEE FIRE STATION 2
11572 CR 252
MCALPIN, FLORIDA
ARCHITECT:
DONNELLY ARCHITECTURE, INCORPORATED
1384 NORTH CITRUS AVENUE
CRYSTAL RIVER, FLORIDA 34428
PHONE: 352.249.1166
STRUCTURAL ENGINEER:
DEVLEN ENGINEERING, INC.
1349 S INTERNATIONAL PARKWAY
SUITE 2441
LAKE MARY, FLORIDA 32746
PHONE: 407.324.5300
MEP ENGINEER:
JOSEPH, LAWRENCE & CO., LLC
1180 HARWOOD AVENUE
SUITE 3000
ALTAMONTE SPRINGS, FLORIDA 32714
PHONE: 321.972.4466
CONTACT INFORMATION:
FIREMAN'S
QUARTERS
FIREMAN'S
QUARTERS
FIREMAN'S
QUARTERS
FIREMAN'S
QUARTERS
OFFICE
OFFICER'S
QUARTERS
MECHANICAL
ROOM
DOMESTIC LAUNDRY
WITH STORAGE
RECREATION/
WORKOUT ROOM
SHOWER
ROOM
DAY
AREA
STORAGE
RESTROOM
#2
RESTROOM
#3
KITCHEN
DINING
AREA
GEAR
STORAGE
APPARATUS BAY
2-H
OUR RATED W
ALL
PER UL U
FE
FE
FE
C
TRAVEL DISTANCE =
145' < 200' MAXIMUM
TR
AV
EL
D
IS
TA
N
CE
' M
AX
IM
U M
TR
AV
EL
D
IS
TA
N
CE
' M
AX
IM
U M
6" P
LU
M
BI
N
G W
AL
L
FE
FE
FE
PASSAGE
6" P
LU
M
BI
N
G W
AL
L
6" PLUMBING WALL
S-2 ENCLOSED PARKING GARAGE < 12,000 SQ DT (FBC 903.2.10) R-2 DWELLING UNIT
TRAVEL D
IST
ANCE =
87' < 200' M
AXIM
UM
DRAIN TO
DRYWELL
BABY
BOX
(FBC 420.2) LIFE SAFETY PLAN,
A0.01
SU
W
A N
N
EE
C O
U N
T Y
FI
R
E R
ES
C
U E
M cA lp in
, F lo rid a
FLORIDA ARCHITECT AR 92950
FI
R
E
ST
A T
IO
N
PROJECT LOCATION:
SUWANEE FIRE STATION 2
11572 CR 252
MCALPIN, FLORIDA
Do nn el ly
P ro je ct
352.249.1166
WWW.DONNELLYARCHITECTURE.COM
Architecture,Donnelly IncorporatedAR92950
825 NW 13TH STREET
GAINESVILLE, FLORIDA 32601
1384 NORTH CITRUS AVENUE
CRYSTAL RIVER, FLORIDA 34428
JULY 20, 2026
100% CONSTRUCTION
DOCUMENTS
CODE SUMMARY
Scale:
Life Safety Floor Plan 1/8" = 1'-0"
NOTES:
1. SEAL ALL PENETRATIONS IN RATED WALLS.
2. PROVIDE PARTITION IDENTIFICATION AS FOLLOWS:
TYPE: PROVIDE STENCILING TO INDICATE WALL RATING AS INDICATED ON DRAWINGS TO STATE "FIRE
AND SMOKE BARRIER - PROTECT ALL OPENINGS" AND LIST WALL RATING.
LOCATION: 10 FEET ON CENTER, BOTH SIDES OF PARTITIONS, ABOVE CEILING LINES. PLACE ABOVE
ACCESS PANELS IN HARD CEILINGS.
STYLE OF LETTERING: 4 INCHES HIGH, ½” STROKE, HELVETICA STYLE, PAINTED WITH AID OF STENCILS.
COLOR: RED.
AT TRANSITIONS WHERE FACE OF WALL CHANGES FROM RATED TO NON-RATED, PROVIDE 2” WIDE VERTICAL STRIPE, 12” TALL AT TRANSITION POINT. PROVIDE STENCILING TO INDICATED RATED AND
NON-RATED SIDES OF TRANSITION.
3. PROVIDE PENETRATION IDENTIFICATION AS FOLLOWS:
IDENTIFY PENETRATION FIRESTOPPING WITH PREPRINTED METAL OR PLASTIC LABELS. ATTACH LABELS PERMANENTLY TO SURFACES ADJACENT TO AND WITHIN 6" OF FIRESTOPPING EDGE SO LABELS WILL BE VISIBLE TO ANYONE SEEKING TO REMOVE PENETRATING ITEMS OR FIRESTOPPING. USE MECHANICAL FASTENERS OR SELF-ADHERING-TYPE LABELS WITH ADHESIVES CAPABLE OF PERMANENTLY BONDING LABELS TO SURFACES ON WHICH LABELS ARE APPLIED. LABELS SHALL INCLUDE THE FOLLOWING
INFORMATION:
THE WORDS:
"WARNING - THIS OPENING HAS BEEN SEALED WITH FIRE PROTECTION PRODUCTS. DO NOT
REMOVE!" SHALL BE PRINTED ON THE LABEL ALONG WITH THE:
INSTALLING CONTRACTOR'S NAME, ADDRESS, AND PHONE NUMBER.
DESIGNATION OF APPLICABLE TESTING OR INSPECTING AGENCY (UL NUMBER) WITH RATING IN
HOURS.
DATE OF INSTALLATION.
FIRESTOPPING MANUFACTURER'S NAME.
INSTALLER'S NAME.
BUILDING CODE SUMMARY:
APPLICABLE CODES:
FLORIDA BUILDING CODE, 8TH EDITION (2023)
FLORIDA FIRE PREVENTION CODE, 8TH EDITION (2021)
FLORIDA BUILDING CODE - PLUMBING, 8TH EDITION (2023)
FLORIDA BUILDING CODE - MECHANICAL, 8TH EDITION (2023)
FLORIDA BUILDING CODE - ACCESSIBILITY, 8TH EDITION (2023)
2020 NATIONAL ELECTRIC CODE
MIXED OCCUPANCY CLASSIFICATION:
RESIDENTIAL (R-2) - LIVE WORK PER FBC 310.1 SPRINKLERED (NFPA 13R)
NFPA 101 - LODGING: THE REQUIREMENTS OF THIS CHAPTER SHALL APPLY TO BUILDINGS THAT
PROVIDE SLEEPING ACCOMMODATIONS FOR 16 OR FEWER PERSONS ON EITHER A TRANSIENT OR
PERMANENT BASIS, WITH OR WITHOUT MEALS, BUT WITHOUT SEPARATE COOKING FACILITIES
FOR INDIVIDUAL OCCUPANTS.
STORAGE (S-2) PER FBC 311.1 SPRINKLERED
NFPA 101 - STORAGE: THE REQUIREMENTS OF THIS CHAPTER SHALL APPLY TO BOTH NEW AND
EXISTING STORAGE OCCUPANCIES.
TOTAL PROJECT AREA: 7,294 SQ FT
OCCUPANT FACTOR (FFPC 7.3.1.2 AND FBC TABLE 1004.5):
3,340 SQ FT RESIDENTIAL/ 200 GROSS
3,954 SQ FT STORAGE/ 300 GROSS
=16.7 + 13.2 = 29.9
= 30 OCCUPANTS
CONSTRUCTION TYPE CLASSIFICATION: NFPA TYPE II (0,0,0) (FIRE RESISTANT)
TYPE IIB, NS PER FBC TABLE 601, TYPE II (0,0,0) PER NFPA 220
ALLOWABLE HEIGHT = 60' (S/R TYPE VB, SPRINKLERED) FBC TABLE 504.3
ALLOWABLE STORIES = 3 (S/R TYPE VB, SPRINKLERED) FBC TABLE 504.4
ALLOWABLE AREA = 92,000 SQ FT (S/R TYPE IIB, SPRINKLERED) FBC TABLE 506.2
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS:
BUILDING ELEMENT: FBC TABLE 601 NFPA 220
STRUCTURAL FRAME (COLUMNS, BEAMS, GIRDERS) 0 0
BEARING WALLS
EXTERIOR 0 0
INTERIOR 0 0
NON BEARING WALLS AND PARTITIONS
EXTERIOR 0 0
INTERIOR 0 0
FLOOR CONSTRUCTION (INCL. BEAMS AND JOISTS) 0 0
ROOF CONSTRUCTION (INCL. BEAMS AND JOISTS) 0 0
OCCUPANCY TYPE SEPARATION:
WALLS 1-HOUR (S/R)
FLOORS N/A
TENANT SPACE SEPARATION:
WALLS N/A
FLOORS N/A
WALL SEPARATING DWELLING UNITS: 30 MIN FIRE PARTITION (FBC 420/708.3)
DOMESTIC LAUNDRY ROOM: 0
INTERIOR FINISH RATINGS:
INTERIOR WALL AND CEILING FINISHES (PER FBC TABLE 803.11)
CORRIDORS CLASS B OR BETTER
ROOMS AND ENCLOSED SPACES CLASS C OR BETTER
INTERIOR FLOOR FINISHES (PER FBC 804.4.2) NOT BE LESS THAN CLASS II
EGRESS REQUIREMENTS:
MINIMUM NUMBER OF EXITS REQUIRED = (2) = 3 EXITS PROVIDED (FBC 1006.2.1 AND 1006.3.2)
MAXIMUM TRAVEL DISTANCE TO EXIT = 200' (SPRINKLERED) (FBC TABLE 1017.2)
MAXIMUM DEAD END CORRIDOR = 20' (FBC 1020.5)
MAXIMUM COMMON PATH OF TRAVEL = 75' (FBC TABLE 1006.2.1)
1-HOUR CORRIDORS NOT REQUIRED PER FBC TABLE 1020.2 SPRINKLERED
EXIT ACCESS THROUGH INTERVENING SPACE ACCEPTABLE PER FBC 1016.2
MINIMUM LEVEL EGRESS COMPONENT WIDTH = .2" X 30 PERSONS = 6" (FFPC, TABLE 7.3.3.1) EGRESS WIDTH PROVIDED = 36" X 3 = 108" > 6" (44" MIN. CORRIDOR WIDTH PER FBC 1020.3)
PORTABLE FIRE EXTINGUISHERS: (SEE LIFE SAFETY LEGEND FOR ADDITIONAL NOTES)
ORDINARY HAZARD
MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER = 75 FEET
1500 SQ FT MAXIMUM PER UNIT OF 'A', PER NFPA 10, TABLE 3-2.1
MINIMUM (2) 2-A EXTINGUISHERS REQUIRED PER NFPA 10 (6 PROVIDED)
FIRE SPRINKLER: NFPA 13R SPRINKLER SYSTEM (SUBMITTAL REQUIRED)
PROVIDED
FIRE ALARM: NFPA 72 - FIRE ALARM SYSTEM (SUBMITTAL REQUIRED)
PROVIDED
PER FBC-P TABLE 403:
WATER CLOSETS: 3 PROVIDED
LAVATORIES: 3 PROVIDED
BATHTUBS/ SHOWERS: 3 PROVIDED
DRINKING FOUNTAIN: NOT REQUIRED
SERVICE SINK: PROVIDED
PLUMBING FIXTURE CALCULATIONS:
EGRESS PATH AND EXIT
(NUMBER INDICATES EGRESS
WIDTH PROVIDED AT THIS EXIT)
ILLUMINATED EXIT SIGN
(NOTE: PROVIDE TACTILE EXIT SIGNAGE PER
FBC 1011.3 ADJACENT TO ALL DOORS WITH EXIT
SIGNS)
FIRE EXTINGUISHER PROVIDE 4A 8Ø BC - DRY
CHEMICAL 10 LB EXTINGUISHER
FIRE EXTINGUISHER IN SEMI-RECESSED CABINET
PROVIDE 4A 8Ø BC - DRY CHEMICAL 10 LB
EXTINGUISHER
36"
LIFE SAFETY LEGEND:
FE
FEC
(5) REQUIRED
(1) REQUIRED
FLOOR PLAN WALL LEGEND:
OPENING TYPE, SEE SHEET A3.001
NOTES:
1. SEE SHEET A1.21 FOR REFLECTED CEILING PLAN.
2. PROVIDE INTERIOR SIGNS (ACCESSIBLE IN TYPE AND LOCATION)
EQUAL TO INPRO ASPEN 6" X 6" AT TOILET ROOMS, STORAGE,
MECHANICAL, STAFF ONLY AREAS. INSTALL AT 5'-0" TO CENTER OF
SIGN ON WALL ADJACENT TO LATCH SIDE. INSTALL SQUARE AND
PLUMB.
3. PROVIDE TACTILE EXIT SIGNS ADJACENT TO ALL DOORS WITH EXIT
SIGNS (SEE A0.01). INSTALL AT 5'-0" TO CENTER OF SIGN ON WALL
ADJACENT TO LATCH SIDE. INSTALL SQUARE AND PLUMB.
GWB ON METAL STUD FRAMING AT 16"
O.C. (SEE A4.10)
A
1-HOUR RATED WALL PER UL U419 58" GWB
EACH SIDE ON 3 - 58" METAL STUD FRAMING
AT 16" O.C.
2 WALL TYPE, SEE SHEET A4.10
FLOOR PLAN LEGEND:
METAL BUILDING EXTERIOR WALLS WITH
GWB ON FURRING
RATED
A0.02
SU
W
A N
N
EE
C O
U N
T Y
FI
R
E R
ES
C
U E
M cA lp in
, F lo rid a
FLORIDA ARCHITECT AR 92950
FI
R
E
ST
A T
IO
N
PROJECT LOCATION:
SUWANEE FIRE STATION 2
11572 CR 252
MCALPIN, FLORIDA
Do nn el ly
P ro je ct
352.249.1166
WWW.DONNELLYARCHITECTURE.COM
Architecture,Donnelly IncorporatedAR92950
825 NW 13TH STREET
GAINESVILLE, FLORIDA 32601
1384 NORTH CITRUS AVENUE
CRYSTAL RIVER, FLORIDA 34428
JULY 20, 2026
100% CONSTRUCTION
DOCUMENTS
ASSEMBLIES
¾
¾ ¾ ¾
AutoCAD SHX Text Design No. U419 Nonbearing Wall Ratings — 1, 2, 3 or 4 Hr (See Items 4 & 5) 1, 2, 3 or 4 Hr (See Items 4 & 5) 1. Floor and Ceiling Runners — (Not shown) — For use with Item 2 - Channel shaped, fabricated from min 25 Floor and Ceiling Runners — (Not shown) — For use with Item 2 - Channel shaped, fabricated from min 25 (Not shown) — For use with Item 2 - Channel shaped, fabricated from min 25 For use with Item 2 - Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min depth to accommodate stud size, with min 1-1/4 in. long legs, attached to floor and ceiling with fasteners 24 in. OC max. 1A. Framing Members* - Floor and Ceiling Runners — Not shown - In lieu of Item 1 — For use with Item 2A, Not shown - In lieu of Item 1 — For use with Item 2A, For use with Item 2A, proprietary channel shaped, min. 3-5/8 in. deep, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, attached to floor and ceiling with fasteners 24 in. OC max. Effective thickness is 0.034 in. CLARKWESTERN BUILDING SYSTEMS INC — UltraSTEEL® UltraSTEEL® DIETRICH INDUSTRIES INC — UltraSTEEL®. UltraSTEEL®. . 1B. Framing Members* - Floor and Ceiling Runners — (Not shown - In lieu of Item 1) — For use with Item 2A, (Not shown - In lieu of Item 1) — For use with Item 2A, For use with Item 2A, proprietary channel shaped, min. 2-1/2 in. deep, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, attached to floor and ceiling fasteners 24 in. OC. max. Effective thickness is 0.034 in. CLARKWESTERN BUILDING SYSTEMS INC — UltraSTEEL® UltraSTEEL® DIETRICH INDUSTRIES INC — UltraSTEEL®. UltraSTEEL®. . 1C. Framing Members* - Floor and Ceiling Runner — Not shown - In lieu of Item 1 — For use with Item 2C, Not shown - In lieu of Item 1 — For use with Item 2C, For use with Item 2C, proprietary channel shaped runners, 3-5/8 in. deep attached to floor and ceiling with fasteners 24 in. OC max. CALIFORNIA EXPANDED METAL PRODUCTS CO — ViperTrack ViperTrack CRACO MFG INC — SmartTrack SmartTrack MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper25 Track Viper25 Track Track 1D. Framing Members* - Floor and Ceiling Runner — Not shown - In lieu of Item 1 — For use with Item 2D, Not shown - In lieu of Item 1 — For use with Item 2D, For use with Item 2D, proprietary channel shaped runners, 1-1/4 in. wide by 3-5/8 in. deep fabricated from min 0.020 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper20S Track, Viper20D Track Viper20S Track, Viper20D Track Track, Viper20D Track Track 1E. Framing Members*— Floor and Ceiling Runners — (Not shown) — In lieu of Item 1 - Channel shaped, attached to Floor and Ceiling Runners — (Not shown) — In lieu of Item 1 - Channel shaped, attached to (Not shown) — In lieu of Item 1 - Channel shaped, attached to In lieu of Item 1 - Channel shaped, attached to floor and ceiling with fasteners 24 in. OC. max. ALLSTEEL & GYPSUM PRODUCTS INC — Type SUPREME Framing System Type SUPREME Framing System CONSOLIDATED FABRICATORS CORP, BUILDING PRODUCTS DIV — Type SUPREME Framing System Type SUPREME Framing System QUAIL RUN BUILDING MATERIALS INC — Type SUPREME Framing System Type SUPREME Framing System SCAFCO STEEL STUD MANUFACTURING CO — Type SUPREME Framing System Type SUPREME Framing System STEEL CONSTRUCTION SYSTEMS INC — Type SUPREME Framing System Type SUPREME Framing System UNITED METAL PRODUCTS INC — Type SUPREME Framing System Type SUPREME Framing System 1F. Floor and Ceiling Runners — (Not shown)—For use with Item 2B- Channel shaped, fabricated from min 20 MSG (Not shown)—For use with Item 2B- Channel shaped, fabricated from min 20 MSG For use with Item 2B- Channel shaped, fabricated from min 20 MSG corrosion-protected or galv steel, min depth to accommodate stud size, with min 1 in. long legs, attached to floor and ceiling with fasteners spaced max 24 in. OC. 1G. Framing Members*— Floor and Ceiling Runners — (Not shown, As an alternate to Item 1) — For use with Item 2F Floor and Ceiling Runners — (Not shown, As an alternate to Item 1) — For use with Item 2F (Not shown, As an alternate to Item 1) — For use with Item 2F For use with Item 2F and 5F or 5G only, channel shaped, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, attached to floor and ceiling with fasteners 24 in. OC. max. CLARKWESTERN BUILDING SYSTEMS INC — CW ProTRAK CW ProTRAK DIETRICH INDUSTRIES INC — DIETRICH ProTRAK DIETRICH ProTRAK DMFCWBS L L C — ProTRAK ProTRAK TELLING INDUSTRIES L L C — TRUE-TRACK TRUE-TRACK 1H. Framing Members* - Floor and Ceiling Runner — Not shown - In lieu of Item 1 — For use with Item 2G, Not shown - In lieu of Item 1 — For use with Item 2G, For use with Item 2G, proprietary channel shaped runners, minimum width to accommodate stud size, with 1- 1/8 in. long legs fabricated from min 0.015 in. (min bare metal thickness) galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. SUPER STUD BUILDING PRODUCTS — The Edge The Edge 2. Steel Studs — Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min depth as indicated Steel Studs — Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min depth as indicated Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min depth as indicated under Item 5, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly height. 2A. Framing Members* - Steel Studs — In lieu of Item 2 - Proprietary channel shaped studs, min. depth as In lieu of Item 2 - Proprietary channel shaped studs, min. depth as indicated under Item 5, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, spaced a max of 24 in. OC. Studs to be cut 3/4 in. less than assembly height. Allowable use of studs is shown in the table below. For direct attachment of gypsum board only. Effective thickness is 0.034 in. CLARKWESTERN BUILDING SYSTEMS INC — UltraSTEEL® UltraSTEEL® DIETRICH INDUSTRIES INC — UltraSTEEL®. UltraSTEEL®. . 2B. Steel Studs — (As an alternate to Item 2, For use with Items 5B & 5E) Channel shaped, fabricated from min 20 (As an alternate to Item 2, For use with Items 5B & 5E) Channel shaped, fabricated from min 20 MSG corrosion-protected or galv steel, 3-1/2 in. min depth, spaced a max of 16 in. OC. Studs friction-fit into floor and ceiling runners. Studs to be cut 5/8 to 3/4 in. less than assembly height. 2C. Framing Members* - Steel Studs — (As an alternate to Item 2, For use with Item 5C) - Proprietary channel (As an alternate to Item 2, For use with Item 5C) - Proprietary channel shaped studs, 3-5/8 in. deep spaced a max of 24 in. OC. Studs to be cut 3/4 in less than the assembly height and installed with a ½ in. gap between the end of the stud and track at the bottom of the wall. For direct attachment of gypsum board only. CALIFORNIA EXPANDED METAL PRODUCTS CO — ViperStud ViperStud CRACO MFG INC — SmartStud SmartStud MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper25 Viper25 2D. Framing Members* - Metal Studs — Not shown - In lieu of Item 2 — For use with Item 1D, proprietary channel Not shown - In lieu of Item 2 — For use with Item 1D, proprietary channel For use with Item 1D, proprietary channel shaped steel studs, min depth as indicated under Item 5, spaced a max if 24 in. OC, fabricated from min 0.020 in. thick galv steel. Studs cut 3/8 in. to 3/4 in. less in lengths than assembly heights. MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper20S , Viper20D Viper20S , Viper20D , Viper20D 2E. Framing Members*— Steel Studs — In lieu of Item 2 - For Use with Item 1E- Channel shaped studs, min depth Steel Studs — In lieu of Item 2 - For Use with Item 1E- Channel shaped studs, min depth In lieu of Item 2 - For Use with Item 1E- Channel shaped studs, min depth as indicated under Item 5, spaced a max of 24 in. OC. Studs to be cut 3/4 in. less than assembly height. ALLSTEEL & GYPSUM PRODUCTS INC — Type SUPREME Framing System Type SUPREME Framing System CONSOLIDATED FABRICATORS CORP, BUILDING PRODUCTS DIV — Type SUPREME Framing System Type SUPREME Framing System QUAIL RUN BUILDING MATERIALS INC — Type SUPREME Framing System Type SUPREME Framing System SCAFCO STEEL STUD MANUFACTURING CO — Type SUPREME Framing System Type SUPREME Framing System STEEL CONSTRUCTION SYSTEMS INC — Type SUPREME Framing System Type SUPREME Framing System UNITED METAL PRODUCTS INC — Type SUPREME Framing System Type SUPREME Framing System 2F. Framing Members*— Steel Studs — (Not shown, As an alternate to Item 2) —For use with Item 1G and 5F or 5G Steel Studs — (Not shown, As an alternate to Item 2) —For use with Item 1G and 5F or 5G (Not shown, As an alternate to Item 2) —For use with Item 1G and 5F or 5G For use with Item 1G and 5F or 5G only, channel shaped studs, min depth as indicated under Item 5F, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, spaced a max of 24 in. OC. Studs to be cut 3/4 in. less than assembly height. CLARKWESTERN BUILDING SYSTEMS INC — CW ProSTUD CW ProSTUD DIETRICH INDUSTRIES INC — DIETRICH ProSTUD DIETRICH ProSTUD DMFCWBS L L C — ProSTUD ProSTUD TELLING INDUSTRIES L L C — TRUE-STUD TRUE-STUD 2G. Framing Members* - Metal Studs — Not shown - In lieu of Item 2 — For use with Item 1H, proprietary channel Not shown - In lieu of Item 2 — For use with Item 1H, proprietary channel For use with Item 1H, proprietary channel shaped steel studs, minimum width indicated under Item 5, 1-1/4 in. deep fabricated from min 0.015 in. (min bare metal thickness) galvanized steel. Studs 3/8 in. to 3/4 in. less in lengths than assembly heights. SUPER STUD BUILDING PRODUCTS — The Edge The Edge 3. Wood Structural Panel Sheathing — (Optional, For use with Item 5 Only.)- (Not Shown) - 4 ft wide, 7/16 in. Wood Structural Panel Sheathing — (Optional, For use with Item 5 Only.)- (Not Shown) - 4 ft wide, 7/16 in. (Optional, For use with Item 5 Only.)- (Not Shown) - 4 ft wide, 7/16 in. thick oriented strand board (OSB) or 15/32 in. thick structural 1 sheathing (plywood) complying with DOC PS1 or PS2, or APA Standard PRP-108, manufactured with exterior glue, applied horizontally or vertically to the steel studs. Vertical joints centered on studs, and staggered one stud space from wallboard joints. Attached to studs with flat-head self-drilling tapping screws with a min. head diam. of 0.292 in. at maximum 6 in. OC. in the perimeter and 12 in. OC. in the field. When used, fastener lengths for gypsum panels increased by min. 1/2 in. 4. Batts and Blankets* — (Required as indicated under Item 5) — Mineral wool batts, friction fitted between studs Batts and Blankets* — (Required as indicated under Item 5) — Mineral wool batts, friction fitted between studs (Required as indicated under Item 5) — Mineral wool batts, friction fitted between studs Mineral wool batts, friction fitted between studs and runners. Min nom thickness as indicated under Item 5. See Batts and Blankets (BKNV or BZJZ) Categories for names of Classified companies. 4A. Batts and Blankets* — (Optional) — Placed in stud cavities, any glass fiber or mineral wool insulation bearing the (Optional) — Placed in stud cavities, any glass fiber or mineral wool insulation bearing the Placed in stud cavities, any glass fiber or mineral wool insulation bearing the UL Classification Marking as to Surface Burning Characteristics and/or Fire Resistance. See Batts and Blankets (BKNV or BZJZ) Categories for names of Classified companies. 5. Gypsum Board* — Gypsum panels with beveled, square or tapered edges, applied vertically or horizontally. Gypsum Board* — Gypsum panels with beveled, square or tapered edges, applied vertically or horizontally. Gypsum panels with beveled, square or tapered edges, applied vertically or horizontally. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Vertical joints in adjacent layers (multilayer systems) staggered one stud cavity. Horizontal joints need not be backed by steel framing. Horizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered. Horizontal edge joints and horizontal butt joints in adjacent layers (multilayer systems) staggered a min of 12 in. The thickness and number of layers for the 1 hr, 2 hr, 3 hr and 4 hr ratings are as follows: Gypsum Board Protection on Each Side of Wall Rating Min Stud Min Stud No. of Insulation Min Stud Min Stud No. of Insulation Min Stud No. of Insulation No. of Insulation Insulation (Hours) depth Depth Layers & (thickness) depth Depth Layers & (thickness) Depth Layers & (thickness) Layers & (thickness) (thickness) 2, 2d, 2e, 2g 2a Min Thkns (Item 4) 2a Min Thkns (Item 4) Min Thkns (Item 4) (Item 4) of Panel 1 3-1/2 3-5/8 1 layer, 5/8 in. thick Optional 3-1/2 3-5/8 1 layer, 5/8 in. thick Optional 3-5/8 1 layer, 5/8 in. thick Optional 1 layer, 5/8 in. thick Optional Optional 1 2-1/2 3-5/8 1 layer, 1/2 in. thick 1-1/2 in. 2-1/2 3-5/8 1 layer, 1/2 in. thick 1-1/2 in. 3-5/8 1 layer, 1/2 in. thick 1-1/2 in. 1 layer, 1/2 in. thick 1-1/2 in. 1-1/2 in. 1 1-5/8 3-5/8 1 layer, 3/4 in. thick Optional 1-5/8 3-5/8 1 layer, 3/4 in. thick Optional 3-5/8 1 layer, 3/4 in. thick Optional 1 layer, 3/4 in. thick Optional Optional 2 1-5/8 2-1/2 2 layers, 1/2 in. thick Optional 1-5/8 2-1/2 2 layers, 1/2 in. thick Optional 2-1/2 2 layers, 1/2 in. thick Optional 2 layers, 1/2 in. thick Optional Optional 2 1-5/8 2-1/2 2 layers, 5/8 in. thick Optional 1-5/8 2-1/2 2 layers, 5/8 in. thick Optional 2-1/2 2 layers, 5/8 in. thick Optional 2 layers, 5/8 in. thick Optional Optional 2 3-1/2 3-5/8 1 layer, 3/4 in. thick 3 in. 3-1/2 3-5/8 1 layer, 3/4 in. thick 3 in. 3-5/8 1 layer, 3/4 in. thick 3 in. 1 layer, 3/4 in. thick 3 in. 3 in. 3 1-5/8 2-1/2 3 layers, 1/2 in. thick Optional 1-5/8 2-1/2 3 layers, 1/2 in. thick Optional 2-1/2 3 layers, 1/2 in. thick Optional 3 layers, 1/2 in. thick Optional Optional 3 1-5/8 2-1/2 2 layers, 3/4 in. thick Optional 1-5/8 2-1/2 2 layers, 3/4 in. thick Optional 2-1/2 2 layers, 3/4 in. thick Optional 2 layers, 3/4 in. thick Optional Optional 3 1-5/8 2-1/2 3 layers, 5/8 in. thick Optional 1-5/8 2-1/2 3 layers, 5/8 in. thick Optional 2-1/2 3 layers, 5/8 in. thick Optional 3 layers, 5/8 in. thick Optional Optional 4 1-5/8 2-1/2 4 layers, 5/8 in. thick Optional 1-5/8 2-1/2 4 layers, 5/8 in. thick Optional 2-1/2 4 layers, 5/8 in. thick Optional 4 layers, 5/8 in. thick Optional Optional 4 1-5/8 2-1/2 4 layers, 1/2 in. thick Optional 1-5/8 2-1/2 4 layers, 1/2 in. thick Optional 2-1/2 4 layers, 1/2 in. thick Optional 4 layers, 1/2 in. thick Optional Optional 4 2-1/2 2-1/2 2 layers, 3/4 in. thick 2 in. 2-1/2 2-1/2 2 layers, 3/4 in. thick 2 in. 2-1/2 2 layers, 3/4 in. thick 2 in. 2 layers, 3/4 in. thick 2 in. 2 in. CANADIAN GYPSUM COMPANY — 1/2 in. thick Type C, IP-X2 or IPC-AR; WRC, 5/8 in. thick Type AR, C, IP-AR, 1/2 in. thick Type C, IP-X2 or IPC-AR; WRC, 5/8 in. thick Type AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, WRX or WRC; 3/4 in. thick Types IP-X3 or ULTRACODE UNITED STATES GYPSUM CO — 1/2 in. thick Type C, IP-X2, IPC-AR or WRC; 5/8 in. thick Type SCX, SHX, WRX, 1/2 in. thick Type C, IP-X2, IPC-AR or WRC; 5/8 in. thick Type SCX, SHX, WRX, IP-X1, AR, C, WRC, FRX-G, IP-AR, IP-X2, IPC-AR ; 3/4 in. thick Types IP-X3 or ULTRACODE USG MEXICO S A DE C V — 1/2 in. thick Type C, IP-X2, IPC-AR or WRC; 5/8 in. thick Type AR, C, IP-AR, IP-X1, 1/2 in. thick Type C, IP-X2, IPC-AR or WRC; 5/8 in. thick Type AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, WRX, WRC or; 3/4 in. thick Types IP-X3 or ULTRACODE When Item 7B, Steel Framing Members*, is used, Nonbearing Wall Rating is limited to 1 Hr. Min. stud depth is 3-1/2 in., min. thickness of insulation (Item 4) is 3 in., and two layers of gypsum board panels (1/2 in. or 5/8 in. thick) shall be attached to furring channels as described in Item 6. One layer of gypsum board panels (1/2 in. or 5/8 in. thick) attached to opposite side of stud without furring channels as described in Item 6. 5A. Gypsum Board* — (As an alternate to Item 5) — 5/8 in. thick, 24 to 54 in. wide, applied horizontally as the (As an alternate to Item 5) — 5/8 in. thick, 24 to 54 in. wide, applied horizontally as the 5/8 in. thick, 24 to 54 in. wide, applied horizontally as the outer layer to one side of the assembly. Secured as described in Item 6. CANADIAN GYPSUM COMPANY — Type SHX. Type SHX. UNITED STATES GYPSUM CO — Type FRX-G, SHX. Type FRX-G, SHX. USG MEXICO S A DE C V — Type SHX. Type SHX. 5B. Gypsum Board* — (Not Shown) - As an alternate to Item 5 when used as the base layer on one or both sides (Not Shown) - As an alternate to Item 5 when used as the base layer on one or both sides of wall when 5/8 in or ¾ in. thick products are specified. For direct attachment only to steel studs Item 2B, (not to in. thick products are specified. For direct attachment only to steel studs Item 2B, (not to be used with Item 3) - Nom 5/8 in. or ¾ in. may be used as alternate to all 5/8 in. or ¾ in. shown in Item 5, in. may be used as alternate to all 5/8 in. or ¾ in. shown in Item 5, in. shown in Item 5, Wallboard Protection on Each Side of Wall table. Nom 5/8 in. or ¾ in. thick lead backed gypsum panels with beveled, in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min 1 stud cavity on opposite sides of studs. Gypsum board secured to 20 MSG steel studs Item 2B with 1-1/4 in. long Type S-12 steel screws spaced 8 in. OC at perimeter and 12 in. OC in the field. To be used with Lead Batten Strips (see Item 11) or Lead Discs or Tabs (see Item 12). RAY-BAR ENGINEERING CORP — Type RB-LBG Type RB-LBG 5C. Gypsum Board* — (For Use With Item 2C) Rating Limited to 1 Hour. 5/8 in. thick, 48 in. wide, Gypsum panels (For Use With Item 2C) Rating Limited to 1 Hour. 5/8 in. thick, 48 in. wide, Gypsum panels with beveled, square or tapered edges, applied vertically or horizontally. (Vertical Application) - The gypsum board is to be installed on each side of the studs with 1 in. long Type S coated steel screws spaced 8 in. OC starting 4 in. from the edge of the board at the vertical edges and 12 in. OC starting 6 in. from the edge of the board at the center of each board. Gypsum boards are to be secured to the top and bottom track with screws spaced 8 in. OC starting 4 in. from the board edge. Fasteners shall not penetrate through both the stud and the track at the same time. Vertical joints are to be centered over studs and staggered one stud cavity on opposite sides of studs. (Horizontal Application) - The gypsum board is to be installed on each side of the studs with 1 in. long Type S coated steel screws spaced 8 in. OC starting 4 in. from the edge of the board at the vertical edges and 12 in. OC starting 6 in. from the edge of the board at the center of each board. Gypsum boards are to be secured to the top and bottom track with screws spaced 8 in. OC starting 4 in. from the board edge. Fasteners shall not penetrate through both the stud and the track at the same time. All horizontal joints are to be backed as outlined under section VI of Volume 1 in the Fire Resistive Directory. CANADIAN GYPSUM COMPANY — Type SCX. Type SCX. UNITED STATES GYPSUM CO — Type SCX. Type SCX. USG MEXICO S A DE C V — Type SCX. Type SCX. 5D. Gypsum Board* — (As an alternate to Item 5) — 5/8 in. thick, 48 in. wide, applied vertically or horizontally. (As an alternate to Item 5) — 5/8 in. thick, 48 in. wide, applied vertically or horizontally. 5/8 in. thick, 48 in. wide, applied vertically or horizontally. Secured as described in Item 6. For use with Items 1 and 2 only. UNITED STATES GYPSUM CO — Type USGX. Type USGX. 5E. Gypsum Board* — (Not Shown) - (As an alternate to Item 5 when used as the base layer on one or both sides (Not Shown) - (As an alternate to Item 5 when used as the base layer on one or both sides of wall when 1/2 in. or 5/8 in thick products are specified, For direct attachment only to steel studs Item 2B, not to be used with Item 3). Nominal 5/8 in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min 1 stud cavity on opposite sides of studs. Wallboard secured to studs with 1-1/4 in. long Type S-12 (or No. 6 by 1-1/4 in. long bugle head fine driller) steel screws spaced 8 in. OC at perimeter and 12 in. OC in the field. NEW ENGLAND LEAD BURNING CO INC, DBA NELCO — Nelco Nelco 5F. Gypsum Board* — (As an alternate to Item 5) — For use with Items 1G and 2F and limited to 1 Hour Rating (As an alternate to Item 5) — For use with Items 1G and 2F and limited to 1 Hour Rating For use with Items 1G and 2F and limited to 1 Hour Rating only, Gypsum panels with beveled, square or tapered edges, applied vertically, and fastened to the steel studs with 1 in. long Type S screws spaced 8 in. OC along vertical and bottom edges and 12 in. OC in the field. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Steel stud depth shall be a minimum 3-5/8 in. UNITED STATES GYPSUM CO — 5/8 in. thick Type SCX. 5/8 in. thick Type SCX. 5G. Gypsum Board* — (As an alternate to Item 5) — For use with Items 1G and 2F only, Gypsum panels with (As an alternate to Item 5) — For use with Items 1G and 2F only, Gypsum panels with For use with Items 1G and 2F only, Gypsum panels with beveled, square or tapered edges, applied vertically or horizontally, as specified in the table below and fastened to the steel studs as described in Item 6. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Vertical joints in adjacent layers (multilayer systems) staggered one stud cavity. Horizontal joints need not be backed by steel framing. Horizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered. Horizontal edge joints and horizontal butt joints in adjacent layers (multilayer systems) staggered a min of 12 in. The thickness and number of layers for the 2 hr, 3 hr and 4 hr ratings are as follows: Gypsum Board Protection on Each Side of Wall Rating, Min Stud No. of Layers Min Thkns of Min Stud No. of Layers Min Thkns of No. of Layers Min Thkns of Min Thkns of Hr Depth, in. & Thickness Insulation Depth, in. & Thickness Insulation & Thickness Insulation Insulation Item 2F of Panel (Item 4) of Panel (Item 4) (Item 4) 2 1-5/8 2 layers, 1/2 in. thick Optional 1-5/8 2 layers, 1/2 in. thick Optional 2 layers, 1/2 in. thick Optional Optional 2 1-5/8 2 layers, 5/8 in. thick Optional 1-5/8 2 layers, 5/8 in. thick Optional 2 layers, 5/8 in. thick Optional Optional 3 5/8 3 layers, 1/2 in. thick Optional 5/8 3 layers, 1/2 in. thick Optional 3 layers, 1/2 in. thick Optional Optional 3 1-5/8 3 layers, 5/8 in. thick Optional 1-5/8 3 layers, 5/8 in. thick Optional 3 layers, 5/8 in. thick Optional Optional 4 1-5/8 4 layers, 5/8 in. thick Optional 1-5/8 4 layers, 5/8 in. thick Optional 4 layers, 5/8 in. thick Optional Optional 4 1-5/8 4 layers, 1/2 in. thick Optional 1-5/8 4 layers, 1/2 in. thick Optional 4 layers, 1/2 in. thick Optional Optional CANADIAN GYPSUM COMPANY — 1/2 in. thick Type C, IP-X2 or IPC-AR;, 5/8 in. thick Type AR, C, IP-AR, IP-X1, 1/2 in. thick Type C, IP-X2 or IPC-AR;, 5/8 in. thick Type AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, or; 3/4 in. thick Types IP-X3 or ULTRACODE UNITED STATES GYPSUM CO — 1/2 in. thick Type C, IP-X2, IPC-AR or; 5/8 in. thick Type SCX, SHX, IP-X1, AR, C, 1/2 in. thick Type C, IP-X2, IPC-AR or; 5/8 in. thick Type SCX, SHX, IP-X1, AR, C, , FRX-G, IP-AR, IP-X2, IPC-AR ; 3/4 in. thick Types IP-X3 or ULTRACODE USG MEXICO S A DE C V — 1/2 in. thick Type C, IP-X2, IPC-AR or; 5/8 in. thick Type AR, C, IP-AR, IP-X1, 1/2 in. thick Type C, IP-X2, IPC-AR or; 5/8 in. thick Type AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, or; 3/4 in. thick Types IP-X3 or ULTRACODE 6. Fasteners — (Not shown) — For use with Items 2 and 2F - Type S or S-12 steel screws used to attach panels Fasteners — (Not shown) — For use with Items 2 and 2F - Type S or S-12 steel screws used to attach panels (Not shown) — For use with Items 2 and 2F - Type S or S-12 steel screws used to attach panels For use with Items 2 and 2F - Type S or S-12 steel screws used to attach panels to studs (Item 2) or furring channels (Item 7). Single layer systems: 1 in. long for 1/2 and 5/8 in. thick panels or 1-1/4 in. long for 3/4 in. thick panels, spaced 8 in. OC when panels are applied horizontally, or 8 in. OC along vertical and bottom edges and 12 in. OC in the field when panels are applied vertically. Two layer systems: First layer- 1 in. long for 1/2 and 5/8 in. thick panels or 1-1/4 in. long for 3/4 in. thick panels, spaced 16 in. OC. Second layer- 1-5/8 in. long for 1/2 in., 5/8 in. thick panels or 2-1/4 in. long for 3/4 in. thick panels, spaced 16 in. OC with screws offset 8 in. from first layer.Three-layer systems: First layer- 1 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Second layer- 1-5/8 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Third layer- 2-1/4 in. long for 1/2 in., 5/8 in. thick panels or 2-5/8 in. long for 5/8 in. thick panels, spaced 12 in. OC. Screws offset min 6 in. from layer below. Four-layer systems: First layer- 1 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Second layer- 1-5/8 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Third layer- 2-1/4 in. long for 1/2 in. thick panels or 2-5/8 in. long for 5/8 in. thick panels, spaced 24 in. OC. Fourth layer- 2-5/8 in. long for 1/2 in. thick panels or 3 in. long for 5/8 in. thick panels, spaced 12 in. OC. Screws offset min 6 in. from layer below. 6A. Fasteners — (Not shown) —For use with Item 2A - Type S or S-12 steel screws used to attach panels to studs (Not shown) —For use with Item 2A - Type S or S-12 steel screws used to attach panels to studs For use with Item 2A - Type S or S-12 steel screws used to attach panels to studs (Item 2A). Single layer systems: 1 in. long for 1/2 and 5/8 in. thick panels or 1-1/4 in. long for 3/4 in. thick panels, spaced 8-1/2 in. OC with additional screws 1 in. and 2-1/2 in. from edges of the board when panels are horizontally. or 8 in. OC along vertical and bottom edges and 12 in. OC in the field when panels are applied vertically. Two layer systems applied vertically: First layer- 1 in. long for 1/2 and 5/8 in. thick panels or 1-1/4 in. long for 3/4 in. thick panels, spaced 16 in. OC. Second layer- 1-5/8 in. long for 1/2 in., 5/8 in. thick panels or 2-1/4 in. long for 3/4 in. thick panels, spaced 16 in. OC with screws offset 8 in. from first layer. Two layer systems applied horizontally: First layer- 1 in. long for 1/2 and 5/8 in. thick panels or 1-1/4 in. long for 3/4 in. thick panels, spaced 16 in. OC starting 8 in. from each edge of the board with an additional screw placed 1-1/4 in. from each edge of the board. Second layer- 1-5/8 in. long for 1/2 in., 5/8 in. thick panels or 2-1/4 in. long for 3/4 in. thick panels, spaced 16 in. OC starting 8 in. from each edge of the board with an additional screw placed 1-1/4 in. from each edge of the board with screws offset 8 in. from first layer. Three-layer systems: First layer- 1 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Second layer- 1-5/8 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Third layer- 2-1/4 in. long for 1/2 in., 5/8 in. thick panels or 2-5/8 in. long for 5/8 in. thick panels, spaced 12 in. OC. Screws offset min 6 in. from layer below. For all layers, an additional screw shall be placed 1-1/4 in. from each edge of the board. Four-layer systems: First layer- 1 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Second layer- 1-5/8 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Third layer- 2-1/4 in. long for 1/2 in. thick panels or 2-5/8 in. long for 5/8 in. thick panels, spaced 24 in. OC. Fourth layer- 2-5/8 in. long for 1/2 in. thick panels or 3 in. long for 5/8 in. thick panels, spaced 12 in. OC. Screws offset min 6 in. from layer below. For all layers, an additional screw shall be placed 1-1/4 in. from each edge of the board. 7. Furring Channels — (Optional, not shown, for single or double layer systems) — Resilient furring channels Furring Channels — (Optional, not shown, for single or double layer systems) — Resilient furring channels (Optional, not shown, for single or double layer systems) — Resilient furring channels Resilient furring channels fabricated from min 25 MSG corrosion-protected steel, spaced vertically a max of 24 in. OC. Flange portion attached to each intersecting stud with 1/2 in. long Type S-12 steel screws. Not for use with Item 5A and 5E. 7A. Framing Members* — (Not Shown) — (Optional on one or both sides, not shown, for single or double layer (Not Shown) — (Optional on one or both sides, not shown, for single or double layer (Optional on one or both sides, not shown, for single or double layer systems) — As an alternate to Item 7, furring channels and Steel Framing Members as described below: As an alternate to Item 7, furring channels and Steel Framing Members as described below: a. Furring Channels — Formed of No. 25 MSG galv steel. 2-3/8 in. wide by 7/8 in. deep, spaced max. 24 in. OC Furring Channels — Formed of No. 25 MSG galv steel. 2-3/8 in. wide by 7/8 in. deep, spaced max. 24 in. OC Formed of No. 25 MSG galv steel. 2-3/8 in. wide by 7/8 in. deep, spaced max. 24 in. OC perpendicular to studs. Channels secured to studs as described in Item b. Gypsum board attached to furring channels as described in Item 6. Not for use with Item 5A and 5E. b. Steel Framing Members* — Used to attach furring channels (Item 7Aa) to studs (Item 2). Clips spaced max. 48 Steel Framing Members* — Used to attach furring channels (Item 7Aa) to studs (Item 2). Clips spaced max. 48 Used to attach furring channels (Item 7Aa) to studs (Item 2). Clips spaced max. 48 in. OC. RSIC-1 clips secured to studs with No. 8 x 1-1/2 in. minimum self-drilling, S-12 steel screw through the center grommet. RSIC-V clips secured to studs with No. 8 x 9/16 in. minimum self-drilling, S-12 steel screw through the center hole. Furring channels are friction fitted into clips. PAC INTERNATIONAL INC — Types RSIC-1, RSIC-V. Types RSIC-1, RSIC-V. 7B. Framing Members* — (Optional, Not Shown) — As an alternate to Item 7, for single or double layer systems, (Optional, Not Shown) — As an alternate to Item 7, for single or double layer systems, As an alternate to Item 7, for single or double layer systems, furring channels and Steel Framing Members on only one side of studs as described below: a. Furring Channels — Formed of No. 25 MSG galv steel, spaced 24 in. OC perpendicular to studs. Channels Furring Channels — Formed of No. 25 MSG galv steel, spaced 24 in. OC perpendicular to studs. Channels Formed of No. 25 MSG galv steel, spaced 24 in. OC perpendicular to studs. Channels secured to studs as described in Item b. Batts and Blankets placed in stud cavity as described in Item 5. Two layers of gypsum board attached to furring channels as described in Item 5. Not for use with Item 5A and 5E. b. Steel Framing Members* — Used to attach furring channels (Item 7Ba) to one side of studs (Item 2) only. Clips Steel Framing Members* — Used to attach furring channels (Item 7Ba) to one side of studs (Item 2) only. Clips Used to attach furring channels (Item 7Ba) to one side of studs (Item 2) only. Clips spaced 48 in. OC., and secured to studs with two No. 8 x 2-1/2 in. coarse drywall screws, one through the hole at each end of the clip. Furring channels are friction fitted into clips. KINETICS NOISE CONTROL INC — Type Isomax Type Isomax 7C. Framing Members* — Optional - Not Shown - Used as an alternate method to attach resilient channels (Item 7). Optional - Not Shown - Used as an alternate method to attach resilient channels (Item 7). Clips attached at each intersection of the resilient channel and the steel studs (Item 2). Resilient channels are friction fitted into clips, and then clips are secured to the steel stud with min. 1 in. long Type S-12 steel screws through the center hole of the clip and the resilient channel flange. KEENE BUILDING PRODUCTS CO INC — Type RC Assurance. Type RC Assurance. 7D. Framing Members* — (Not Shown) — (Optional on one or both sides, not shown, for single or double layer (Not Shown) — (Optional on one or both sides, not shown, for single or double layer (Optional on one or both sides, not shown, for single or double layer systems) — As an alternate to Item 7, furring channels and Steel Framing Members as described below: As an alternate to Item 7, furring channels and Steel Framing Members as described below: a. Furring Channels — Formed of No. 25 MSG galv steel. 2-3/8 in. wide by 7/8 in. deep, spaced max. 24 in. OC Furring Channels — Formed of No. 25 MSG galv steel. 2-3/8 in. wide by 7/8 in. deep, spaced max. 24 in. OC Formed of No. 25 MSG galv steel. 2-3/8 in. wide by 7/8 in. deep, spaced max. 24 in. OC perpendicular to studs. Channels secured to studs as described in Item b. Gypsum board attached to furring channels as described in Item 6. Not for use with Item 5A and 5E. b. Steel Framing Members* — Used to attach furring channels (Item 7Aa) to studs (Item 2). Clips spaced max. 48 Steel Framing Members* — Used to attach furring channels (Item 7Aa) to studs (Item 2). Clips spaced max. 48 Used to attach furring channels (Item 7Aa) to studs (Item 2). Clips spaced max. 48 in. OC. GENIECLIPS secured to studs with No. 8 x 1-1/2 in. minimum self-drilling, S-12 steel screw through the center grommet. Furring channels are friction fitted into clips. PLITEQ INC — Type GENIECLIP Type GENIECLIP 8. Joint Tape and Compound — Vinyl or casein, dry or premixed joint compound applied in two coats to joints and Joint Tape and Compound — Vinyl or casein, dry or premixed joint compound applied in two coats to joints and Vinyl or casein, dry or premixed joint compound applied in two coats to joints and screw heads of outer layers. Paper tape, nom 2 in. wide, embedded in first layer of compound over all joints of outer layer panels. Paper tape and joint compound may be omitted when gypsum panels are supplied with a square edge. 9. Siding, Brick or Stucco — (Optional, not shown) — Aluminum, vinyl or steel siding, brick veneer or stucco, Siding, Brick or Stucco — (Optional, not shown) — Aluminum, vinyl or steel siding, brick veneer or stucco, (Optional, not shown) — Aluminum, vinyl or steel siding, brick veneer or stucco, Aluminum, vinyl or steel siding, brick veneer or stucco, meeting the requirements of local code agencies, installed over gypsum panels. Brick veneer attached to studs with corrugated metal wall ties attached to each stud with steel screws, not more than each sixth course of brick. 10. Caulking and Sealants* — (Optional, not shown) — A bead of acoustical sealant applied around the partition Caulking and Sealants* — (Optional, not shown) — A bead of acoustical sealant applied around the partition (Optional, not shown) — A bead of acoustical sealant applied around the partition A bead of acoustical sealant applied around the partition perimeter for sound control. UNITED STATES GYPSUM CO — Type AS Type AS 11. Lead Batten Strips — (Not Shown, For Use With Item 5B) - Lead batten strips, min 1-1/2 in. wide, max 10 ft Lead Batten Strips — (Not Shown, For Use With Item 5B) - Lead batten strips, min 1-1/2 in. wide, max 10 ft (Not Shown, For Use With Item 5B) - Lead batten strips, min 1-1/2 in. wide, max 10 ft long with a max thickness of 0.125 in. Strips placed on the interior face of studs and attached from the exterior face of the stud with two 1 in. long Type S-12 pan head steel screws, one at the top of the strip and one at the bottom of the strip. Lead batten strips to have a purity of 99.9% meeting the Federal specification QQ-L-201f, Grade "C". Lead batten strips required behind vertical joints of lead backed gypsum wallboard (Item 5B) and optional at remaining stud locations. Required behind vertical joints. 12. Lead Discs or Tabs — (Not Shown, For Use With Item 5B) - Used in lieu of or in addition to the lead batten Lead Discs or Tabs — (Not Shown, For Use With Item 5B) - Used in lieu of or in addition to the lead batten (Not Shown, For Use With Item 5B) - Used in lieu of or in addition to the lead batten strips (Item 11) or optional at other locations - Max 3/4 in. diam by max 0.125 in. thick lead discs compression fitted or adhered over steel screw heads or max 1/2 in. by 1-1/4 in. by max 0.125 in. thick lead tabs placed on gypsum boards (Item 5B) underneath screw locations prior to the installation of the screws. Lead discs or tabs to have a purity of 99.9% meeting the Federal specification QQ-L-201f, Grade "C". 13. Lead Batten Strips — (Not Shown, For Use With Item 5E) Lead batten strips, 2 in. wide, max 10 ft long with a Lead Batten Strips — (Not Shown, For Use With Item 5E) Lead batten strips, 2 in. wide, max 10 ft long with a (Not Shown, For Use With Item 5E) Lead batten strips, 2 in. wide, max 10 ft long with a max thickness of 0.142 in. Strips placed on the face of studs and attached to the stud with two min. 1 in. long min. Type S-8 pan head steel screws, one at the top of the strip and one at the bottom of the strip or with one min. 1 in. long min. Type S-8 pan head steel screw at the top of the strip. Lead batten strips to have a purity of 99.9% meeting the Federal specification QQ-L-201f, Grade "C". Lead batten strips required behind vertical joints of lead backed gypsum wallboard (Item 5E) and optional at remaining stud locations. 14. Lead Tabs — (Not Shown, For Use With Item 5E) 2 in. wide, 5 in. long with a max thickness of 0.142 in. Tabs Lead Tabs — (Not Shown, For Use With Item 5E) 2 in. wide, 5 in. long with a max thickness of 0.142 in. Tabs (Not Shown, For Use With Item 5E) 2 in. wide, 5 in. long with a max thickness of 0.142 in. Tabs friction-fit around front face of stud, the stud folded back flange, and the back face of the stud. Tabs required at each location where a screw (that secures the gypsum boards, Item 5E) will penetrate the steel stud. Lead tabs to have a purity of 99.9% meeting the Federal specification QQ-L-201f, Grade "C". Lead tabs may be held in place with standard adhesive tape if necessary.
AutoCAD SHX Text System No. W-L-1001 June 15, 2005 F Ratings — 1, 2, 3 and 4 Hr (See Items 2 and 3) 1, 2, 3 and 4 Hr (See Items 2 and 3) T Ratings — 0, 1, 2, 3, and 4 Hr (See Item 3) 0, 1, 2, 3, and 4 Hr (See Item 3) L Rating At Ambient — less than 1 CFM/sq ft less than 1 CFM/sq ft L Rating At 400 F — less than 1 CFM/sq ft less than 1 CFM/sq ft 1. Wall Assembly — The 1, 2, 3 or 4 hr fire-rated gypsum wallboard/stud wall Wall Assembly — The 1, 2, 3 or 4 hr fire-rated gypsum wallboard/stud wall The 1, 2, 3 or 4 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs (max 2 h fire rated Studs — Wall framing may consist of either wood studs (max 2 h fire rated Wall framing may consist of either wood studs (max 2 h fire rated assemblies) or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC with nom 2 by 4 in. (51 by 102 mm) lumber end plates and cross braces. Steel studs to be min 3-5/8 in. (92 mm) wide by 1-3/8 in. (35 mm) deep channels spaced max 24 in. (610 mm) OC. B. Gypsum Board* — Nom 1/2 or 5/8 in. (13 or 16 mm) thick, 4 ft.